1
|
Corsato PCR, de Lima LF, Paschoarelli MV, de Araujo WR. Electrochemical sensing at the fingertips: wearable glove-based sensors for detection of 4-nitrophenol, picric acid and diazepam. CHEMOSPHERE 2024:142771. [PMID: 38969219 DOI: 10.1016/j.chemosphere.2024.142771] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 06/18/2024] [Accepted: 07/03/2024] [Indexed: 07/07/2024]
Abstract
A wearable glove-based sensor is a portable and practical approach for onsite detection/monitoring of a variety of chemical threats. Herein, we report a flexible and sensitive wearable sensor fabricated on the nitrile glove fingertips by stencil-printing technique. The working electrodes were modified with multiwalled carbon nanotubes (MWCNTs)/poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) for sensitive and real-time analyses of hazardous or chemical treats, as picric acid (PA) explosive, diazepam (DZ) as drug-facilitated crimes and the emerging pollutant 4-nitrophenol (4-NP). The multi-sensing platform towards PA, 4-NP, and DZ offers the ability of in-situ qualitative and quantitative analyses of powder and liquid samples. A simple sampling by touching or swiping the fingertip sensor on the sample or surface under investigation using an ionic hydrogel combined with fast voltammetry measurement provides timely point-of-need analyses. The wearable glove-based sensor uses the square wave voltammetry (SWV) technique and exhibited excellent performance to detect PA, 4-NP, and DZ, resulting in limits of detection (LOD) of 0.24 μM, 0.35 μM, 0.06 μM, respectively, in a wide concentration range (from 0.5 μM to 100 μM). Also, we obtained excellent manufacturing reproducibility with relative standard deviations (RSD) in the range of 3.65% to 4.61% using 7 different wearable devices (n=7) and stability in the range of 4.86% to 6.61% using different electrodes stored for 10 days at room temperature (n=10), demonstrating the excellent sensor-to-sensor reproducibility and stability for reliable in-field measurements. The stretchable sensor presented great mechanical robustness, supporting up to 80 bending or stretching deformation cycles without significant voltammetric changes. Collectively, our wearable glove-based sensor may be employed for analyses of chemical contaminants of concern, such as explosives (PA), drugs (DZ), and emerging pollutants (4-NP), helping in environmental and public safety control.
Collapse
Affiliation(s)
- Paula C R Corsato
- Laboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas - UNICAMP, 13083-970, Campinas, SP, Brazil
| | - Lucas F de Lima
- Laboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas - UNICAMP, 13083-970, Campinas, SP, Brazil
| | - Mayra V Paschoarelli
- Laboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas - UNICAMP, 13083-970, Campinas, SP, Brazil
| | - William R de Araujo
- Laboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas - UNICAMP, 13083-970, Campinas, SP, Brazil.
| |
Collapse
|
2
|
Balamurugan TST, Stelmaszczyk P, Wietecha-Posłuszny R, Poltorak L. Electroanalytical characterization of clozapine at the electrified liquid-liquid interface and its detection in soft and hard drinks. Analyst 2024; 149:2073-2083. [PMID: 38415352 DOI: 10.1039/d3an02188b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/29/2024]
Abstract
Clozapine (CZ) is a prescribed benzodiazepine psychiatric drug that is often possessed as an illicit drug and is associated with drug-facilitated sexual assaults (DFSA) due to its strong sedative capabilities. Hence, we propose an electrified liquid-liquid interface (eLLI) based transducing element as an alternative electroanalytical platform for rapid screening of CZ in soft and hard drinks which is habitually associated with DFSA crimes. First, molecular partitioning and the effect of chemical composition, pH, and the presence of ethanol in the biphasic configuration of the aqueous phase on the interfacial behaviour and analytical performance of the CZ at the eLLI have been investigated with voltammetry. Next, the electrochemical profiles of various soft and hard drinks were studied at the eLLI. The eLLI-based CZ sensor has shown a broad dynamic range (15-150 μM), lower detection limits (1μM), and adequate reliability towards rapid CZ screening in spiked soft and hard drink samples with reference to the standard chromatographic analysis.
Collapse
Affiliation(s)
- Thangaraj S T Balamurugan
- Electrochemistry@Soft Interfaces Team, Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, 91-403, Lodz, Poland.
| | - Paweł Stelmaszczyk
- Laboratory for Forensic Chemistry, Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387, Krakow, Poland
- Doctoral School of Exact and Natural Sciences, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387, Krakow, Poland
| | - Renata Wietecha-Posłuszny
- Laboratory for Forensic Chemistry, Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387, Krakow, Poland
| | - Lukasz Poltorak
- Electrochemistry@Soft Interfaces Team, Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, 91-403, Lodz, Poland.
| |
Collapse
|
3
|
Moreira NS, Pinheiro KMP, Sousa LR, Garcia GDS, Figueredo F, Coltro WKT. Distance-based detection of paracetamol in microfluidic paper-based analytical devices for forensic application. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 16:33-39. [PMID: 38010169 DOI: 10.1039/d3ay01739g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2023]
Abstract
Whisky adulteration is a prevalent practice driven by the high cost of these beverages. Counterfeiters commonly dilute whisky with less expensive alcoholic beverages, water, food additives, drugs or pharmaceuticals. Paracetamol (PAR), an analgesic drug that mitigates hangovers and headaches, is commonly used to adulterate whisky. Currently, the primary method for quantifying PAR levels is high-performance liquid chromatography, but this technique is both time consuming and usually generates more residues. In this context, the utilization of miniaturized and portable analytical devices becomes imperative for conducting point-of-care/need analyses. These devices offer several advantages, including portability, user-friendliness, low cost, and minimal material wastage. This study proposes the selective distance-based PAR quantification on whisky samples using a paper-based microfluidic analytical device (μPAD). Colorimetric detection on paper-based platforms offers great benefits such as affordability, portability, and the ability to detect PAR without complicated instrumentation. The optimal detection conditions were achieved by introducing 5 μL of a mixture containing 7.5 mmol L-1 of Fe(III) and K3[Fe(CN)6] into the detection zone, along with 12 μL of whisky samples into the sample zone. The method exhibited linear behavior within the concentration range from 15 to 120 mg L-1, with a determination coefficient of 0.998. PAR was quantified in adulterated samples. The results obtained with the paper-based devices were compared with a referenced method, and no significant differences were observed at a confidence level of 95%. The μPAD allowed to determine ca. 1 drop of pharmaceutical medicine PAR of 200 mg mL-1 in 1 L of solution, demonstrating excellent sensitivity. This method offers cost-effective and rapid analysis, reducing the consumption of samples, reagents, and wastes. Consequently, it could be considered a viable and portable alternative for analyzing beverages at criminal scenes, customs, and police operations, thereby enhancing the field of forensics.
Collapse
Affiliation(s)
- Nikaele S Moreira
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
| | - Kemilly M P Pinheiro
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
| | - Lucas R Sousa
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
- Laboratorio de Biosensores y Bioanálisis (LABB), Departamento de Química Biológica e IQUIBICEN - CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), Pabellón 2, Ciudad Universitaria, Ciudad Autónoma de Buenos Aires, Argentina
| | - Gabriel D S Garcia
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
| | - Federico Figueredo
- Laboratorio de Biosensores y Bioanálisis (LABB), Departamento de Química Biológica e IQUIBICEN - CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), Pabellón 2, Ciudad Universitaria, Ciudad Autónoma de Buenos Aires, Argentina
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
- Laboratorio de Biosensores y Bioanálisis (LABB), Departamento de Química Biológica e IQUIBICEN - CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), Pabellón 2, Ciudad Universitaria, Ciudad Autónoma de Buenos Aires, Argentina
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13084-971, Campinas, SP, Brazil
| |
Collapse
|
4
|
de Lima LF, Barbosa PP, Simeoni CL, de Paula RFDO, Proenca-Modena JL, de Araujo WR. Electrochemical Paper-Based Nanobiosensor for Rapid and Sensitive Detection of Monkeypox Virus. ACS APPLIED MATERIALS & INTERFACES 2023; 15:58079-58091. [PMID: 38063784 DOI: 10.1021/acsami.3c10730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2023]
Abstract
Monkeypox virus (MPXV) infection was classified as a public health emergency of international concern by the World Health Organization (WHO) in 2022, being transmitted between humans by large respiratory droplets, in contact with skin lesions, fomites, and sexually. Currently, there are no available accessible and simple-to-use diagnostic tests that accurately detect MPXV antigens for decentralized and frequent testing. Here, we report an electrochemical biosensor to detect MPXV antigens in saliva and plasma samples within 15 min using accessible materials. The electrochemical system was manufactured onto a paper substrate engraved by a CO2 laser machine, modified with gold nanostructures (AuNS) and a monoclonal antibody, enabling sensitive detection of A29 viral protein. The diagnostic test is based on the use of electrochemical impedance spectroscopy (EIS) and can be run by a miniaturized potentiostat connected to a smartphone. The impedimetric biosensing method presented excellent analytical parameters, enabling the detection of A29 glycoprotein in the concentration ranging from 1 × 10-14 to 1 × 10-7 g mL-1, with a limit of detection (LOD) of 3.0 × 10-16 g mL-1. Furthermore, it enabled the detection of MPXV antigens in the concentration ranging from 1 × 10-1 to 1 × 104 PFU mL-1, with an LOD of 7.8 × 10-3 PFU mL-1. Importantly, no cross-reactivity was observed when our device was tested in the presence of other poxvirus and nonpoxvirus strains, indicating the adequate selectivity of our nanobiosensor for MPXV detection. Collectively, the nanobiosensor presents high greenness metrics associated with the use of a reproducible and large-scale fabrication method, an accessible and sustainable paper substrate, and a low volume of sample (2.5 μL), which could facilitate frequent testing of MPXV at point-of-care (POC).
Collapse
Affiliation(s)
- Lucas F de Lima
- Portable Chemical Sensors Lab, Department of Analytical Chemistry, Institute of Chemistry, State University of Campinas - UNICAMP, P.O. Box 6154, 13083-970 Campinas, SP, Brazil
| | - Priscilla P Barbosa
- Laboratory of Emerging Viruses, Department of Genetics, Evolution, Microbiology and Immunology, University of Campinas, Campinas, 13083-862 Campinas, SP, Brazil
- Experimental Medicine Research Cluster, State University of Campinas, Campinas, 13083-862 Campinas, SP, Brazil
| | - Camila L Simeoni
- Laboratory of Emerging Viruses, Department of Genetics, Evolution, Microbiology and Immunology, University of Campinas, Campinas, 13083-862 Campinas, SP, Brazil
- Experimental Medicine Research Cluster, State University of Campinas, Campinas, 13083-862 Campinas, SP, Brazil
| | - Rosemeire F de O de Paula
- Laboratory of Emerging Viruses, Department of Genetics, Evolution, Microbiology and Immunology, University of Campinas, Campinas, 13083-862 Campinas, SP, Brazil
| | - José Luiz Proenca-Modena
- Laboratory of Emerging Viruses, Department of Genetics, Evolution, Microbiology and Immunology, University of Campinas, Campinas, 13083-862 Campinas, SP, Brazil
- Experimental Medicine Research Cluster, State University of Campinas, Campinas, 13083-862 Campinas, SP, Brazil
| | - William R de Araujo
- Portable Chemical Sensors Lab, Department of Analytical Chemistry, Institute of Chemistry, State University of Campinas - UNICAMP, P.O. Box 6154, 13083-970 Campinas, SP, Brazil
| |
Collapse
|
5
|
Matias TA, Ramos DLO, Faria LV, de Siervo A, Richter EM, Muñoz RAA. 3D-printed electrochemical cells with laser engraving: developing portable electroanalytical devices for forensic applications. Mikrochim Acta 2023; 190:297. [PMID: 37460848 DOI: 10.1007/s00604-023-05872-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 06/14/2023] [Indexed: 08/09/2023]
Abstract
A new electrochemical device fabricated by the combination of 3D printing manufacturing and laser-generated graphene sensors is presented. Cell and electrodes were 3D printed by the fused deposition modeling (FDM) technique employing acrylonitrile butadiene styrene filament (insulating material that composes the cell) and conductive filament (lab-made filament based on graphite dispersed into polylactic acid matrix) to obtain reference and auxiliary electrodes. Infrared-laser engraved graphene, also reported as laser-induced graphene (LIG), was produced by laser conversion of a polyimide substrate, which was assembled in the 3D-printed electrochemical cell that enables the analysis of low volumes (50-2000 μL). XPS analysis revealed the formation of nitrogen-doped graphene multilayers that resulted in excellent electrochemical sensing properties toward the detection of atropine (ATR), a substance that was found in beverages to facilitate sexual assault and other criminal acts. Linear range between 5 and 35 μmol L-1, detection limit of 1 μmol L-1, and adequate precision (RSD = 4.7%, n = 10) were achieved using differential-pulse voltammetry. The method was successfully applied to beverage samples with recovery values ranging from 80 to 105%. Interference studies in the presence of species commonly found in beverages confirmed satisfactory selectivity for ATR sensing. The devices proposed are useful portable analytical tools for on-site applications in the forensic scenario.
Collapse
Affiliation(s)
- Tiago A Matias
- Center for Research on Electroanalysis, Institute of Chemistry, Federal University of Uberlândia, Uberlândia, MG, 38408-100, Brazil.
| | - David L O Ramos
- Center for Research on Electroanalysis, Institute of Chemistry, Federal University of Uberlândia, Uberlândia, MG, 38408-100, Brazil
| | - Lucas V Faria
- Center for Research on Electroanalysis, Institute of Chemistry, Federal University of Uberlândia, Uberlândia, MG, 38408-100, Brazil
| | - Abner de Siervo
- Institute of Physics Gleb Wataghin, Applied Physics Department, State University of Campinas, Campinas, SP, 13083-859, Brazil
| | - Eduardo M Richter
- Center for Research on Electroanalysis, Institute of Chemistry, Federal University of Uberlândia, Uberlândia, MG, 38408-100, Brazil
| | - Rodrigo A A Muñoz
- Center for Research on Electroanalysis, Institute of Chemistry, Federal University of Uberlândia, Uberlândia, MG, 38408-100, Brazil.
| |
Collapse
|