1
|
Cen Z, Huang Y, Li S, Dong S, Wang W, Li X. Advancing Breathomics through Accurate Discrimination of Endogenous from Exogenous Volatiles in Breath. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:18541-18553. [PMID: 39340814 DOI: 10.1021/acs.est.4c04575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/30/2024]
Abstract
Breathomics, a growing field in exposure monitoring and clinical diagnostics, has faced accuracy challenges due to unclear contributing factors. This study aims to enhance the potential of breathomics in various frontiers by categorizing exhaled volatile organic compounds (VOCs) as endogenous or exogenous. Analyzing ambient air and breath samples from 271 volunteers via TD-GC × GC-TOF MS/FID, we identify and quantify 50 common VOCs in exhaled breath. Advanced quantitative structure-property relationships and compartment models are employed to obtain VOCs kinetic parameters. This in-depth approach allows us to accurately determine the alveolar concentration of VOCs and further discern their origins, facilitating personalized application of breathomics in exposure assessment and disease diagnosis. Our findings demonstrate that prolonged external exposure turns humans into secondary pollutant sources. Analysis of endogenous VOCs reveals that internal exposure poses more significant health risks than external. Moreover, by correcting environmental backgrounds, we improve the accuracy of gastrointestinal disease diagnostic models by 15-25%. This advancement in identifying VOC origins via compartmental models promises to elevate the clinical relevance of breathomics, marking a leap forward in exposure assessment and precision medicine.
Collapse
Affiliation(s)
- Zhengnan Cen
- Department of Environmental Science & Engineering, Fudan University, Shanghai 200438, P. R. China
| | - Yuerun Huang
- Department of Environmental Science & Engineering, Fudan University, Shanghai 200438, P. R. China
| | - Shangzhewen Li
- Department of Environmental Science & Engineering, Fudan University, Shanghai 200438, P. R. China
| | - Shanshan Dong
- Department of Environmental Science & Engineering, Fudan University, Shanghai 200438, P. R. China
| | - Wenshan Wang
- Department of Environmental Science & Engineering, Fudan University, Shanghai 200438, P. R. China
| | - Xiang Li
- Department of Environmental Science & Engineering, Fudan University, Shanghai 200438, P. R. China
- Institute of Eco-Chongming (IEC), Shanghai 200062, P. R. China
| |
Collapse
|
2
|
Chou H, Godbeer L, Allsworth M, Boyle B, Ball ML. Progress and challenges of developing volatile metabolites from exhaled breath as a biomarker platform. Metabolomics 2024; 20:72. [PMID: 38977623 PMCID: PMC11230972 DOI: 10.1007/s11306-024-02142-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Accepted: 06/13/2024] [Indexed: 07/10/2024]
Abstract
BACKGROUND The multitude of metabolites generated by physiological processes in the body can serve as valuable biomarkers for many clinical purposes. They can provide a window into relevant metabolic pathways for health and disease, as well as be candidate therapeutic targets. A subset of these metabolites generated in the human body are volatile, known as volatile organic compounds (VOCs), which can be detected in exhaled breath. These can diffuse from their point of origin throughout the body into the bloodstream and exchange into the air in the lungs. For this reason, breath VOC analysis has become a focus of biomedical research hoping to translate new useful biomarkers by taking advantage of the non-invasive nature of breath sampling, as well as the rapid rate of collection over short periods of time that can occur. Despite the promise of breath analysis as an additional platform for metabolomic analysis, no VOC breath biomarkers have successfully been implemented into a clinical setting as of the time of this review. AIM OF REVIEW This review aims to summarize the progress made to address the major methodological challenges, including standardization, that have historically limited the translation of breath VOC biomarkers into the clinic. We highlight what steps can be taken to improve these issues within new and ongoing breath research to promote the successful development of the VOCs in breath as a robust source of candidate biomarkers. We also highlight key recent papers across select fields, critically reviewing the progress made in the past few years to advance breath research. KEY SCIENTIFIC CONCEPTS OF REVIEW VOCs are a set of metabolites that can be sampled in exhaled breath to act as advantageous biomarkers in a variety of clinical contexts.
Collapse
|
3
|
Chen J, Ji Y, Liu Y, Cen Z, Chen Y, Zhang Y, Li X, Li X. Exhaled volatolomics profiling facilitates personalized screening for gastric cancer. Cancer Lett 2024; 590:216881. [PMID: 38614384 DOI: 10.1016/j.canlet.2024.216881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 04/02/2024] [Accepted: 04/09/2024] [Indexed: 04/15/2024]
Abstract
Gastric cancer (GC) is one of the most fatal cancers, characterized by non-specific early symptoms and difficulty in detection. However, there are no valid non-invasive screening tools available for GC. Here we establish a non-invasive method that employs exhaled volatolomics and ensemble learning to detect GC. We developed a comprehensive mass spectrometry-based procedure and determined of a wide range of volatolomics from 314 breath samples. The discovery, identification and verification research screened a biomarker panel to distinguish GC from controls. This panel has achieved 0.90 (0.87-0.94, 95%CI) accuracy, with an area under curve (AUC) of 0.92 (0.89-0.94, 95%CI) in discovery cohort and 0.88 (0.83-0.91, 95%CI) accuracy with an AUC of 0.91 (0.87-0.93, 95%CI) in replication cohort, which outperformed traditional serum markers. Single-cell sequencing and gene set enrichment analysis revealed that these exhaled markers originated from aldehyde oxidation and pyruvate metabolism. Our approach advances the design of exhaled analysis for GC detection and holds promise as a non-invasive method to the clinic.
Collapse
Affiliation(s)
- Jian Chen
- Department of Environmental Science & Engineering, Fudan University, Shanghai, 200438, PR China
| | - Yongyan Ji
- Department of Environmental Science & Engineering, Fudan University, Shanghai, 200438, PR China
| | - Yongqian Liu
- Department of Environmental Science & Engineering, Fudan University, Shanghai, 200438, PR China
| | - Zhengnan Cen
- Department of Environmental Science & Engineering, Fudan University, Shanghai, 200438, PR China
| | - Yuanwen Chen
- Department of Gastroenterology, Huadong Hospital Affiliated to Fudan University, Shanghai, 200040, PR China
| | - Yixuan Zhang
- Department of Gastroenterology, Huadong Hospital Affiliated to Fudan University, Shanghai, 200040, PR China
| | - Xiaowen Li
- Department of Gastroenterology, Huadong Hospital Affiliated to Fudan University, Shanghai, 200040, PR China.
| | - Xiang Li
- Department of Environmental Science & Engineering, Fudan University, Shanghai, 200438, PR China.
| |
Collapse
|
4
|
Bajo-Fernández M, Souza-Silva ÉA, Barbas C, Rey-Stolle MF, García A. GC-MS-based metabolomics of volatile organic compounds in exhaled breath: applications in health and disease. A review. Front Mol Biosci 2024; 10:1295955. [PMID: 38298553 PMCID: PMC10828970 DOI: 10.3389/fmolb.2023.1295955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 12/05/2023] [Indexed: 02/02/2024] Open
Abstract
Exhaled breath analysis, with particular emphasis on volatile organic compounds, represents a growing area of clinical research due to its obvious advantages over other diagnostic tests. Numerous pathologies have been extensively investigated for the identification of specific biomarkers in exhalates through metabolomics. However, the transference of breath tests to clinics remains limited, mainly due to deficiency in methodological standardization. Critical steps include the selection of breath sample types, collection devices, and enrichment techniques. GC-MS is the reference analytical technique for the analysis of volatile organic compounds in exhalates, especially during the biomarker discovery phase in metabolomics. This review comprehensively examines and compares metabolomic studies focusing on cancer, lung diseases, and infectious diseases. In addition to delving into the experimental designs reported, it also provides a critical discussion of the methodological aspects, ranging from the experimental design and sample collection to the identification of potential pathology-specific biomarkers.
Collapse
Affiliation(s)
- María Bajo-Fernández
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| | - Érica A. Souza-Silva
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
- Departmento de Química, Universidade Federal de São Paulo (UNIFESP), Diadema, Brazil
| | - Coral Barbas
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| | - Ma Fernanda Rey-Stolle
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| | - Antonia García
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| |
Collapse
|
5
|
Gaida M, Stefanuto PH, Focant JF. Theoretical modeling and machine learning-based data processing workflows in comprehensive two-dimensional gas chromatography-A review. J Chromatogr A 2023; 1711:464467. [PMID: 37871505 DOI: 10.1016/j.chroma.2023.464467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Revised: 10/15/2023] [Accepted: 10/17/2023] [Indexed: 10/25/2023]
Abstract
In recent years, comprehensive two-dimensional gas chromatography (GC × GC) has been gradually gaining prominence as a preferred method for the analysis of complex samples due to its higher peak capacity and resolution power compared to conventional gas chromatography (GC). Nonetheless, to fully benefit from the capabilities of GC × GC, a holistic approach to method development and data processing is essential for a successful and informative analysis. Method development enables the fine-tuning of the chromatographic separation, resulting in high-quality data. While generating such data is pivotal, it does not necessarily guarantee that meaningful information will be extracted from it. To this end, the first part of this manuscript reviews the importance of theoretical modeling in achieving good optimization of the separation conditions, ultimately improving the quality of the chromatographic separation. Multiple theoretical modeling approaches are discussed, with a special focus on thermodynamic-based modeling. The second part of this review highlights the importance of establishing robust data processing workflows, with a special emphasis on the use of advanced data processing tools such as, Machine Learning (ML) algorithms. Three widely used ML algorithms are discussed: Random Forest (RF), Support Vector Machine (SVM), and Partial Least Square-Discriminate Analysis (PLS-DA), highlighting their role in discovery-based analysis.
Collapse
Affiliation(s)
- Meriem Gaida
- Organic and Biological Analytical Chemistry Group (OBiAChem), MolSys Research Unit, Liège University, Belgium
| | - Pierre-Hugues Stefanuto
- Organic and Biological Analytical Chemistry Group (OBiAChem), MolSys Research Unit, Liège University, Belgium
| | - Jean-François Focant
- Organic and Biological Analytical Chemistry Group (OBiAChem), MolSys Research Unit, Liège University, Belgium
| |
Collapse
|