1
|
Feng J, Dong L, Wang H, Xie Y, Wang H, Ding L, Song G, Zhang J, Li T, Shen Q, Zhang Y. Application of aptamer-conjugated graphene oxide for specific enrichment of microcystin-LR in Achatina fulica prior to matrix-assisted laser desorption ionization mass spectrometry. Electrophoresis 2024; 45:275-287. [PMID: 37768831 DOI: 10.1002/elps.202300107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 09/08/2023] [Accepted: 09/14/2023] [Indexed: 09/30/2023]
Abstract
Microcystin-LR (MC-LR), as a hepatotoxin, can cause liver swelling, hepatitis, and even liver cancer. In this study, MC-LR aptamer (Apt-3) modified graphene oxide (GO) was designed to enrich MC-LR in white jade snail (Achatina fulica) and pond water, followed by matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) analysis. Results indicated that the Apt-3/PEG/GO nanocomposites were highly specific to MC-LR, and the detection limit of MALDI-MS was 0.50 ng/mL. Moreover, the MC-LR can be released from nanocomposites at 75°C, thus, the reuse of Apt-3/PEG/GO is realized. Real sample analysis indicated that the Apt-3/PEG/GO nanocomposites coupled with MALDI-MS were efficient in detecting trace amounts of MC-LR in real samples. With the merits of being low cost, reusable, and easy to besynthesized, this Apt-3/PEG/GO MALDI-MS is expected to be comprehensively applied by anchoring suitable aptamers for different targets.
Collapse
Affiliation(s)
- Junli Feng
- Collaborative Innovation Center of Seafood Deep Processing, Zhejiang Province Joint Key Laboratory of Aquatic Products Processing, Institute of Seafood, Zhejiang Gongshang University, Hangzhou, P. R. China
| | - Linpei Dong
- Institute of Forensic Science, Ministry of Public Security, Beijing, P. R. China
| | - Haixing Wang
- Key Laboratory of Drug Monitoring and Control of Zhejiang Province, National Anti-Drug Laboratory Zhejiang Regional Center, Hangzhou, P. R. China
| | - Yihong Xie
- Heart Center, Department of Cardiovascular Surgery, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, P. R. China
| | - Huizi Wang
- Heart Center, Department of Cardiovascular Surgery, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, P. R. China
| | - Lan Ding
- Heart Center, Department of Cardiovascular Surgery, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, P. R. China
| | - Gongshuai Song
- Collaborative Innovation Center of Seafood Deep Processing, Zhejiang Province Joint Key Laboratory of Aquatic Products Processing, Institute of Seafood, Zhejiang Gongshang University, Hangzhou, P. R. China
| | - Jian Zhang
- Collaborative Innovation Center of Seafood Deep Processing, Zhejiang Province Joint Key Laboratory of Aquatic Products Processing, Institute of Seafood, Zhejiang Gongshang University, Hangzhou, P. R. China
| | - Ting Li
- Affiliated Hangzhou Xixi Hospital, Zhejiang University School of Medicine, Hangzhou, P. R. China
| | - Qing Shen
- Collaborative Innovation Center of Seafood Deep Processing, Zhejiang Province Joint Key Laboratory of Aquatic Products Processing, Institute of Seafood, Zhejiang Gongshang University, Hangzhou, P. R. China
| | - Yunfeng Zhang
- Institute of Forensic Science, Ministry of Public Security, Beijing, P. R. China
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, P. R. China
| |
Collapse
|
2
|
Badagian N, Pírez Schirmer M, Pérez Parada A, Gonzalez-Sapienza G, Brena BM. Determination of Microcystins in Fish Tissue by ELISA and MALDI-TOF MS Using a Highly Specific Single Domain Antibody. Toxins (Basel) 2023; 15:toxins15020084. [PMID: 36828400 PMCID: PMC9966346 DOI: 10.3390/toxins15020084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 01/05/2023] [Accepted: 01/12/2023] [Indexed: 01/20/2023] Open
Abstract
The development of simple, reliable, and cost-effective methods is critically important to study the spatial and temporal variation of microcystins (MCs) in the food chain. Nanobodies (Nbs), antigen binding fragments from camelid antibodies, present valuable features for analytical applications. Their small antigen binding site offers a focused recognition of small analytes, reducing spurious cross-reactivity and matrix effects. A high affinity and broad cross-reactivity anti-MCs-Nb, from a llama antibody library, was validated in enzyme linked immunosorbent assay (ELISA), and bound to magnetic particles with an internal standard for pre-concentration in quantitative-matrix-assisted laser desorption ionization-time of flight mass spectrometry (Nb-QMALDI MS). Both methods are easy and fast; ELISA provides a global result, while Nb-QMALDI MS allows for the quantification of individual congeners and showed excellent performance in the fish muscle extracts. The ELISA assay range was 1.8-29 ng/g and for Nb-QMALDI, it was 0.29-29 ng/g fish ww. Fifty-five fish from a MC-containing dam were analyzed by both methods. The correlation ELISA/sum of the MC congeners by Nb-QMALDI-MS was very high (r Spearman = 0.9645, p < 0.0001). Using ROC curves, ELISA cut-off limits were defined to accurately predict the sum of MCs by Nb-QMALDI-MS (100% sensitivity; ≥89% specificity). Both methods were shown to be simple and efficient for screening MCs in fish muscle to prioritize samples for confirmatory methods.
Collapse
Affiliation(s)
- Natalia Badagian
- Biochemistry Area, Department of Biosciences, Faculty of Chemistry, Universidad de la República, Av. Gral. Flores 2124, Montevideo 11800, Uruguay
| | - Macarena Pírez Schirmer
- Immunology Area, Department of Biosciences, Faculty of Chemistry, Universidad de la República, Av A. Navarro 3051, Montevideo 11600, Uruguay
| | - Andrés Pérez Parada
- Technological Development Department, Centro Universitario Regional del Este, Universidad de la República, Ruta 9, Rocha 27000, Uruguay
| | - Gualberto Gonzalez-Sapienza
- Immunology Area, Department of Biosciences, Faculty of Chemistry, Universidad de la República, Av A. Navarro 3051, Montevideo 11600, Uruguay
| | - Beatriz M. Brena
- Biochemistry Area, Department of Biosciences, Faculty of Chemistry, Universidad de la República, Av. Gral. Flores 2124, Montevideo 11800, Uruguay
- Correspondence:
| |
Collapse
|
3
|
Panda D, Dash BP, Manickam S, Boczkaj G. Recent advancements in LC-MS based analysis of biotoxins: Present and future challenges. MASS SPECTROMETRY REVIEWS 2022; 41:766-803. [PMID: 33624883 DOI: 10.1002/mas.21689] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 02/03/2021] [Accepted: 02/05/2021] [Indexed: 06/12/2023]
Abstract
There has been a rising concern regarding the harmful impact of biotoxins, source of origin, and the determination of the specific type of toxin. With numerous reports on their extensive spread, biotoxins pose a critical challenge to figure out their parent groups, metabolites, and concentration. In that aspect, liquid chromatography-mass spectrometry (LC-MS) based analysis paves the way for its accurate identification and quantification. The biotoxins are ideally categorized as phytotoxins, mycotoxins, shellfish-toxins, ciguatoxins, cyanotoxins, and bacterial toxins such as tetrodotoxins. Considering the diverse nature of biotoxins, both low-resolution mass spectrometry (LRMS) and high-resolution mass spectrometry (HRMS) methods have been implemented for their detection. The sample preparation strategy for complex matrix usually includes "QuEChERS" extraction or solid-phase extraction coupled with homogenization and centrifugation. For targeted analysis of biotoxins, the LRMS consisting of a tandem mass spectrometer operating in multiple reaction monitoring mode has been widely implemented. With the help of the reference standard, most of the toxins were accurately quantified. At the same time, the suspect screening and nontarget screening approach are facilitated by the HRMS platforms during the absence of reference standards. Significant progress has also been made in sampling device employment, utilizing novel sample preparation strategies, synthesizing toxin standards, employing hybrid MS platforms, and the associated data interpretation. This critical review attempts to elucidate the progress in LC-MS based analysis in the determination of biotoxins while pointing out major challenges and suggestions for future development.
Collapse
Affiliation(s)
- Debabrata Panda
- Center of Excellence (CoE), Fakir Mohan University, Nuapadhi, Odisha, India
| | - Bisnu P Dash
- Department of Bioscience and Biotechnology, Fakir Mohan University, Nuapadhi, Odisha, India
| | - Sivakumar Manickam
- Petroleum and Chemical Engineering, Faculty of Engineering, Universiti Teknologi Brunei, Bandar Seri Begawan, Brunei Darussalam
| | - Grzegorz Boczkaj
- Department of Process Engineering and Chemical Technology, Faculty of Chemistry, Gdansk University of Technology, Gdańsk, Poland
| |
Collapse
|
4
|
Tian Y, Gao X, Qi WL, Wang Y, Wang X, Zhou J, Lu D, Chen B. Advances in differentiation and identification of foodborne bacteria using near infrared spectroscopy. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:2558-2566. [PMID: 34095906 DOI: 10.1039/d1ay00124h] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Rapid and sensitive detection of foodborne bacteria is a growing concern for ensuring safe food supply and preventing human foodborne infections. It is difficult for conventional methods to meet these detection requirements because they are often tedious and time-consuming. In the recent years, near infrared (NIR) spectroscopy has been found to be a promising method for all sorts of analyses in microbiology due to its highly specific absorption signature and non-destructive measurements. In this review, we first briefly introduce the fundamental and basic operational procedure of NIR spectroscopy for foodborne bacteria detection. Then we summarize the main advances and contributions of this technique in the study of foodborne bacteria. Finally, we conclude that much work still remains to be done before NIR spectroscopy really becomes a viable alternative in the field of microbiological characterization.
Collapse
Affiliation(s)
- Yanlong Tian
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, PR China.
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Filatova D, Núñez O, Farré M. Ultra-Trace Analysis of Cyanotoxins by Liquid Chromatography Coupled to High-Resolution Mass Spectrometry. Toxins (Basel) 2020; 12:toxins12040247. [PMID: 32290413 PMCID: PMC7232229 DOI: 10.3390/toxins12040247] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 04/07/2020] [Accepted: 04/07/2020] [Indexed: 12/19/2022] Open
Abstract
The increasing frequency of episodes of harmful algal blooms of cyanobacterial origin is a risk to ecosystems and human health. The main human hazard may arise from drinking water supply and recreational water use. For this reason, efficient multiclass analytical methods are needed to assess the level of cyanotoxins in water reservoirs and tackle these problems. This work describes the development of a fast, sensitive, and robust analytical method for multiclass cyanotoxins determination based on dual solid-phase extraction (SPE) procedure using a polymeric cartridge, Oasis HLB (Waters Corporation, Milford, MA, USA), and a graphitized non-porous carbon cartridge, SupelcleanTM ENVI-CarbTM (Sigma-Aldrich, St. Louis, MO, USA), followed by ultra-high-performance liquid chromatography high-resolution mass spectrometry (SPE-UHPLC-HRMS). This method enabled the analysis of cylindrospermopsin, anatoxin-a, nodularin, and seven microcystins (MC-LR, MC-RR, MC-YR, MC-LA, MC-LY, MC-LW, MC-LF). The method limits of detection (MLOD) of the validated approach were between 4 and 150 pg/L. The analytical method was applied to assess the presence of the selected toxins in 21 samples collected in three natural water reservoirs in the Ter River in Catalonia (NE of Spain) used to produce drinking water for Barcelona city (Spain).
Collapse
Affiliation(s)
- Daria Filatova
- Department of Environmental Chemistry, IDAEA-CSIC, 08034 Barcelona, Spain;
| | - Oscar Núñez
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, 08028 Barcelona, Spain;
- Serra Húnter Professor, Generalitat de Catalunya, 08007 Barcelona, Spain
| | - Marinella Farré
- Department of Environmental Chemistry, IDAEA-CSIC, 08034 Barcelona, Spain;
- Correspondence:
| |
Collapse
|
6
|
Roegner A, Truong L, Weirich C, Pírez-Schirmer M, Brena B, Miller TR, Tanguay R. Combined Danio rerio embryo morbidity, mortality and photomotor response assay: A tool for developmental risk assessment from chronic cyanoHAB exposure. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 697:134210. [PMID: 32380631 PMCID: PMC7111134 DOI: 10.1016/j.scitotenv.2019.134210] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 08/19/2019] [Accepted: 08/29/2019] [Indexed: 05/28/2023]
Abstract
Freshwater harmful algal blooms produce a broad array of bioactive compounds, with variable polarity. Acute exposure to cyanotoxins can impact the liver, nervous system, gastrointestinal tract, skin, and immune function. Increasing evidence suggests chronic effects from low-level exposures of cyanotoxins and other associated bioactive metabolites of cyanobacterial origin. These sundry compounds persist in drinking and recreational waters and challenge resource managers in detection and removal. A systematic approach to assess the developmental toxicity of cyanobacterial metabolite standards was employed utilizing a robust and high throughput developmental Danio rerio embryo platform that incorporated a neurobehavioral endpoint, photomotor response. Subsequently, we applied the platform to cyanobacterial bloom surface water samples taken from temperate recreational beaches and tropical lake subsistence drinking water sources as a model approach. Dechorionated Danio rerio embryos were statically immersed beginning at four to six hours post fertilization at environmentally relevant concentrations, and then assessed at 24 h and 5 days for morbidity, morphological changes, and photomotor response. At least one assessed endpoint deviated significantly for exposed embryos for 22 out of 25 metabolites examined. Notably, the alkaloid lyngbyatoxin-a resulted in profound, dose-dependent morbidity and mortality beginning at 5 μg/L. In addition, hydrophobic components of extracts from beach monitoring resulted in potent morbidity and mortality despite only trace cyanotoxins detected. The hydrophilic extracts with several order of magnitude higher concentrations of microcystins resulted in no morbidity or mortality. Developmental photomotor response was consistently altered in environmental bloom samples, independent of the presence or concentration of toxins detected in extracts. While limited with respect to more polar compounds, this novel screening approach complements specific fingerprinting of acutely toxic metabolites with robust assessment of developmental toxicity, critical for chronic exposure scenarios.
Collapse
Affiliation(s)
- Amber Roegner
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR, 97331, USA.
| | - Lisa Truong
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR, 97331, USA; Sinnhuber Aquatic Research Laboratory, Oregon State University, 28645 East Highway 34, Corvallis, OR 97333, USA
| | - Chelsea Weirich
- Joseph J. Zilber School of Public Health, University of Wisconsin-Milwaukee, Milwaukee, WI 53211, USA
| | - Macarena Pírez-Schirmer
- Departamento de Biociencias, Cátedra de Inmunología, Facultad de Química, Universidad de la República, Instituto de Higiene, A. Navarro 3051, 11600 Montevideo, Uruguay
| | - Beatriz Brena
- Departamento de Biociencias, Cátedra de Inmunología, Facultad de Química, Universidad de la República, Instituto de Higiene, A. Navarro 3051, 11600 Montevideo, Uruguay; Departamento de Biociencias, Cátedra de Bioquímica, Facultad de Química, Universidad de la República, Gral. Flores 2124, 11800 Montevideo, Uruguay
| | - Todd R Miller
- Joseph J. Zilber School of Public Health, University of Wisconsin-Milwaukee, Milwaukee, WI 53211, USA
| | - Robert Tanguay
- Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR, 97331, USA; Sinnhuber Aquatic Research Laboratory, Oregon State University, 28645 East Highway 34, Corvallis, OR 97333, USA
| |
Collapse
|
7
|
Pírez-Schirmer M, Brena BM, González-Sapienza G. Oriented Functionalization of Magnetic Beads with in Vivo Biotinylated Nanobodies for Rapid MALDI-TOF MS Ultrasensitive Quantitation of Microcystins in Biological Samples. Anal Chem 2019; 91:9925-9931. [DOI: 10.1021/acs.analchem.9b01596] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
8
|
Simultaneous Detection of 14 Microcystin Congeners from Tissue Samples Using UPLC- ESI-MS/MS and Two Different Deuterated Synthetic Microcystins as Internal Standards. Toxins (Basel) 2019; 11:toxins11070388. [PMID: 31269739 PMCID: PMC6669509 DOI: 10.3390/toxins11070388] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Revised: 06/21/2019] [Accepted: 06/28/2019] [Indexed: 02/02/2023] Open
Abstract
Cyanobacterial microcystins (MCs), potent serine/threonine-phosphatase inhibitors, pose an increasing threat to humans. Current detection methods are optimised for water matrices with only a few MC congeners simultaneously detected. However, as MC congeners are known to differ in their toxicity, methods are needed that simultaneously quantify the congeners present, thus allowing for summary hazard and risk assessment. Moreover, detection of MCs should be expanded to complex matrices, e.g., blood and tissue samples, to verify in situ MC concentrations, thus providing for improved exposure assessment and hazard interpretation. To achieve this, we applied two synthetic deuterated MC standards and optimised the tissue extraction protocol for the simultaneous detection of 14 MC congeners in a single ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) run. This procedure was validated using plasma and liver homogenates of mice (male and female) spiked with deuterated MC standards. For proof of concept, tissue and plasma samples from mice i.p. injected with MC-LR and MC-LF were analysed. While MC-LF was detected in all tissue samples of both sexes, detection of MC-LR was restricted to liver samples of male mice, suggesting different toxicokinetics in males, e.g., transport, conjugation or protein binding. Thus, deconjugation/-proteinisation steps should be employed to improve detection of bound MC.
Collapse
|
9
|
Nelis JLD, Tsagkaris AS, Zhao Y, Lou-Franco J, Nolan P, Zhou H, Cao C, Rafferty K, Hajslova J, Elliott CT, Campbell K. The end user sensor tree: An end-user friendly sensor database. Biosens Bioelectron 2019; 130:245-253. [PMID: 30769289 DOI: 10.1016/j.bios.2019.01.055] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Revised: 01/21/2019] [Accepted: 01/22/2019] [Indexed: 11/18/2022]
Abstract
Detailed knowledge regarding sensor based technologies for the detection of food contamination often remains concealed within scientific journals or divided between numerous commercial kits which prevents optimal connectivity between companies and end-users. To overcome this barrier The End user Sensor Tree (TEST) has been developed. TEST is a comprehensive, interactive platform including over 900 sensor based methods, retrieved from the scientific literature and commercial market, for aquatic-toxins, mycotoxins, pesticides and microorganism detection. Key analytical parameters are recorded in excel files while a novel classification system is used which provides, tailor-made, experts' feedback using an online decision tree and database introduced here. Additionally, a critical comparison of reviewed sensors is presented alongside a global perspective on research pioneers and commercially available products. The lack of commercial uptake of the academically popular electrochemical and nanomaterial based sensors, as well as multiplexing platforms became very apparent and reasons for this anomaly are discussed.
Collapse
Affiliation(s)
- J L D Nelis
- Institute for Global Food Security, School of Biological Sciences, Queen's University, David Keir Building, Stranmillis Road, Belfast BT9 5AG, UK
| | - A S Tsagkaris
- Department of Food Analysis and Nutrition, Faculty of Food and Biochemical Technology, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6 - Dejvice, Prague, Czech Republic
| | - Y Zhao
- Institute for Global Food Security, School of Biological Sciences, Queen's University, David Keir Building, Stranmillis Road, Belfast BT9 5AG, UK; School of Electronics, Electrical Engineering and Computer Science, Queen's University Belfast, Stranmillis Road, Belfast, UK
| | - J Lou-Franco
- Institute for Global Food Security, School of Biological Sciences, Queen's University, David Keir Building, Stranmillis Road, Belfast BT9 5AG, UK
| | - P Nolan
- Institute for Global Food Security, School of Biological Sciences, Queen's University, David Keir Building, Stranmillis Road, Belfast BT9 5AG, UK
| | - H Zhou
- School of Electronics, Electrical Engineering and Computer Science, Queen's University Belfast, Stranmillis Road, Belfast, UK; Department of Informatics, University of Leicester, University Road, Leicester LE1 7RH, UK
| | - C Cao
- Institute for Global Food Security, School of Biological Sciences, Queen's University, David Keir Building, Stranmillis Road, Belfast BT9 5AG, UK
| | - K Rafferty
- School of Electronics, Electrical Engineering and Computer Science, Queen's University Belfast, Stranmillis Road, Belfast, UK
| | - J Hajslova
- Department of Food Analysis and Nutrition, Faculty of Food and Biochemical Technology, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6 - Dejvice, Prague, Czech Republic
| | - C T Elliott
- Institute for Global Food Security, School of Biological Sciences, Queen's University, David Keir Building, Stranmillis Road, Belfast BT9 5AG, UK
| | - K Campbell
- Institute for Global Food Security, School of Biological Sciences, Queen's University, David Keir Building, Stranmillis Road, Belfast BT9 5AG, UK.
| |
Collapse
|
10
|
Wu Z, Khan M, Mao S, Lin L, Lin JM. Combination of nano-material enrichment and dead-end filtration for uniform and rapid sample preparation in matrix-assisted laser desorption/ionization mass spectrometry. Talanta 2018; 181:217-223. [DOI: 10.1016/j.talanta.2018.01.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 12/30/2017] [Accepted: 01/07/2018] [Indexed: 11/15/2022]
|
11
|
Rzagalinski I, Volmer DA. Quantification of low molecular weight compounds by MALDI imaging mass spectrometry - A tutorial review. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS 2016; 1865:726-739. [PMID: 28012871 DOI: 10.1016/j.bbapap.2016.12.011] [Citation(s) in RCA: 92] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2016] [Revised: 12/01/2016] [Accepted: 12/19/2016] [Indexed: 10/20/2022]
Abstract
Matrix-assisted laser desorption/ionization (MALDI)-mass spectrometry imaging (MSI) permits label-free in situ analysis of chemical compounds directly from the surface of two-dimensional biological tissue slices. It links qualitative molecular information of compounds to their spatial coordinates and distribution within the investigated tissue. MALDI-MSI can also provide the quantitative amounts of target compounds in the tissue, if proper calibration techniques are performed. Obviously, as the target molecules are embedded within the biological tissue environment and analysis must be performed at their precise locations, there is no possibility for extensive sample clean-up routines or chromatographic separations as usually performed with homogenized biological materials; ion suppression phenomena therefore become a critical side effect of MALDI-MSI. Absolute quantification by MALDI-MSI should provide an accurate value of the concentration/amount of the compound of interest in relatively small, well-defined region of interest of the examined tissue, ideally in a single pixel. This goal is extremely challenging and will not only depend on the technical possibilities and limitations of the MSI instrument hardware, but equally on the chosen calibration/standardization strategy. These strategies are the main focus of this article and are discussed and contrasted in detail in this tutorial review. This article is part of a Special Issue entitled: MALDI Imaging, edited by Dr. Corinna Henkel and Prof. Peter Hoffmann.
Collapse
Affiliation(s)
- Ignacy Rzagalinski
- Institute of Bioanalytical Chemistry, Saarland University, 66123 Saarbrücken, Germany
| | - Dietrich A Volmer
- Institute of Bioanalytical Chemistry, Saarland University, 66123 Saarbrücken, Germany.
| |
Collapse
|