1
|
Ventura-Enríquez Y, Casas-Guerrero A, Sánchez-Guzmán MDJ, Loyola-Cruz MÁ, Cruz-Cruz C, Nolasco-Rojas AE, Durán-Manuel EM, Blanco-Hernández DMR, Álvarez-Mora F, Ibáñez-Cervantes G, Cureño-Díaz MA, Bello-López JM, Fernández-Sánchez V. Plasma Photoinactivation of Bacterial Isolated from Blood Donors Skin: Potential of Security Barrier in Transfusional Therapy. Pathogens 2024; 13:577. [PMID: 39057804 PMCID: PMC11280016 DOI: 10.3390/pathogens13070577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 07/05/2024] [Accepted: 07/09/2024] [Indexed: 07/28/2024] Open
Abstract
The presence of skin bacteria capable of forming biofilm, exhibiting antibiotic resistance, and displaying virulence represents a significant challenge in the field of transfusion medicine. This underscores the necessity of enhancing the microbiological safety of blood and blood components against pathogens with virulent characteristics. The aim of this work was to demonstrate bacterial inactivation in plasma by using a photoinactivation method against virulent bacteria and to evaluate coagulation factors before and after treatment. Logarithmic loads of biofilm-producing, antibiotic-resistant, and virulent bacteria isolated from skin (Enterobacter cloacae, Klebsiella ozaenae, and Staphylococcus epidermidis) were used in artificial contamination assays of fresh frozen plasma bags and subjected to photoreduction. FVIII and FI activity were evaluated before and after photoinactivation. The photoinactivation of plasma was demonstrated to be an effective method for the elimination of these bacteria. However, the efficiency of this method was found to be dependent on the bacterial load and the type of test microorganism. Conversely, decay of coagulation factors was observed with net residual activities of 61 and 69% for FVIII and FI, respectively. The photoinactivation system could have a bias in its effectiveness that is dependent on the test pathogen. These findings highlight the importance of employing technologies that increase the safety of the recipient of blood and/or blood components, especially against virulent bacteria, and show the relevance of the role of photoinactivation systems as an option in transfusion practice.
Collapse
Affiliation(s)
| | | | | | | | - Clemente Cruz-Cruz
- Hospital Juárez de México, Mexico City 07760, Mexico
- Escuela Superior de Medicina, Instituto Politécnico Nacional, Mexico City 11340, Mexico
| | - Andres Emmanuel Nolasco-Rojas
- Hospital Juárez de México, Mexico City 07760, Mexico
- Escuela Superior de Medicina, Instituto Politécnico Nacional, Mexico City 11340, Mexico
| | - Emilio Mariano Durán-Manuel
- Hospital Juárez de México, Mexico City 07760, Mexico
- Escuela Superior de Medicina, Instituto Politécnico Nacional, Mexico City 11340, Mexico
| | | | | | - Gabriela Ibáñez-Cervantes
- Hospital Juárez de México, Mexico City 07760, Mexico
- Escuela Superior de Medicina, Instituto Politécnico Nacional, Mexico City 11340, Mexico
| | | | | | - Verónica Fernández-Sánchez
- Banco de Sangre, Centro Médico Naval (CEMENAV), Mexico City 04470, Mexico
- Hospital Juárez de México, Mexico City 07760, Mexico
- Facultad de Estudios Superiores Iztacala (FES-Iztacala), Universidad Nacional Autónoma de México (UNAM), Mexico City 54090, Mexico
| |
Collapse
|
2
|
Polymerizable Skin Hydrogel for Full Thickness Wound Healing. Int J Mol Sci 2022; 23:ijms23094837. [PMID: 35563225 PMCID: PMC9100232 DOI: 10.3390/ijms23094837] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 04/25/2022] [Accepted: 04/26/2022] [Indexed: 12/11/2022] Open
Abstract
The skin is the largest organ in the human body, comprising the main barrier against the environment. When the skin loses its integrity, it is critical to replace it to prevent water loss and the proliferation of opportunistic infections. For more than 40 years, tissue-engineered skin grafts have been based on the in vitro culture of keratinocytes over different scaffolds, requiring between 3 to 4 weeks of tissue culture before being used clinically. In this study, we describe the development of a polymerizable skin hydrogel consisting of keratinocytes and fibroblast entrapped within a fibrin scaffold. We histologically characterized the construct and evaluated its use on an in vivo wound healing model of skin damage. Our results indicate that the proposed methodology can be used to effectively regenerate skin wounds, avoiding the secondary in vitro culture steps and thus, shortening the time needed until transplantation in comparison with other bilayer skin models. This is achievable due to the instant polymerization of the keratinocytes and fibroblast combination that allows a direct application on the wound. We suggest that the polymerizable skin hydrogel is an inexpensive, easy and rapid treatment that could be transferred into clinical practice in order to improve the treatment of skin wounds.
Collapse
|
3
|
Castiglia S, Adamini A, Rustichelli D, Castello L, Mareschi K, Pinnetta G, Leone M, Mandese A, Ferrero I, Mesiano G, Fagioli F. Cytokines induced killer cells produced in good manufacturing practices conditions: identification of the most advantageous and safest expansion method in terms of viability, cellular growth and identity. J Transl Med 2018; 16:237. [PMID: 30157948 PMCID: PMC6116438 DOI: 10.1186/s12967-018-1613-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Accepted: 08/21/2018] [Indexed: 12/14/2022] Open
Abstract
Background Cytokine-induced killer (CIK) cells are a very promising cell population raising growing interest in the field of cellular antitumor therapy. The aim of our study was to validate the most advantageous expansion method for this advanced therapy medicinal product (ATMP) and to translate it from preclinical field to good manufacturing practices (GMP). GMP ensures that ATMP are consistently produced and controlled to the quality standards required to their intended use. For this reason, the use of the xenogenic sera tended to be minimized by GMP for their high variability and the associated risk of transmitting infectious agents. Results We decided to replace Fetal Bovine Serum (FBS), largely used as medium supplement for CIKs expansion, with other culture media. Firstly, Human Serum (HS) and Human Pool Plasma (HPP) were tested as medium supplements giving not compliant results to acceptance criteria, established for CIKs, probably for the great batch to batch variability. Consequently, we decided to test three different serum free expansion media: X-VIVO 15, (largely used by other groups) and Tex Macs and Cell Genix GMP SCGM: two GMP manufactured media. We performed a validation consisting in three run-sand even if the small number of experiments didn’t permit us to obtained statistical results we demonstrated that both X-VIVO 15 and Tex Macs fulfilled the quality standards in terms of cellular growth, viability and identity while Cell Genix GMP SCGM resulted not compliant as it caused some technical problems such as high mortality. Conclusion In conclusion, these preclinical validation data lay the bases for a GMP-compliant process to improve the CIKs expansion method.
Collapse
Affiliation(s)
- Sara Castiglia
- City of Health and Science Hospital of Turin, Pediatric Oncoematology, Regina Margherita Children's Hospital, Piazza Polonia 94, 10126, Turin, Italy.
| | - Aloe Adamini
- City of Health and Science Hospital of Turin, Pediatric Oncoematology, Regina Margherita Children's Hospital, Piazza Polonia 94, 10126, Turin, Italy
| | - Deborah Rustichelli
- City of Health and Science Hospital of Turin, Pediatric Oncoematology, Regina Margherita Children's Hospital, Piazza Polonia 94, 10126, Turin, Italy
| | - Laura Castello
- City of Health and Science Hospital of Turin, Pediatric Oncoematology, Regina Margherita Children's Hospital, Piazza Polonia 94, 10126, Turin, Italy
| | - Katia Mareschi
- City of Health and Science Hospital of Turin, Pediatric Oncoematology, Regina Margherita Children's Hospital, Piazza Polonia 94, 10126, Turin, Italy.,Department of Public Health and Pediatrics, University of Turin, 10126, Turin, Italy
| | - Giuseppe Pinnetta
- City of Health and Science Hospital of Turin, Pediatric Oncoematology, Regina Margherita Children's Hospital, Piazza Polonia 94, 10126, Turin, Italy
| | - Marco Leone
- City of Health and Science Hospital of Turin, Pediatric Oncoematology, Regina Margherita Children's Hospital, Piazza Polonia 94, 10126, Turin, Italy
| | - Alessandra Mandese
- City of Health and Science Hospital of Turin, Pediatric Oncoematology, Regina Margherita Children's Hospital, Piazza Polonia 94, 10126, Turin, Italy
| | - Ivana Ferrero
- City of Health and Science Hospital of Turin, Pediatric Oncoematology, Regina Margherita Children's Hospital, Piazza Polonia 94, 10126, Turin, Italy.,Department of Public Health and Pediatrics, University of Turin, 10126, Turin, Italy
| | | | - Franca Fagioli
- City of Health and Science Hospital of Turin, Pediatric Oncoematology, Regina Margherita Children's Hospital, Piazza Polonia 94, 10126, Turin, Italy.,Department of Public Health and Pediatrics, University of Turin, 10126, Turin, Italy
| |
Collapse
|
4
|
Bello-López JM, Delgado-Balbuena L, Rojas-Huidobro D, Rojo-Medina J. Treatment of platelet concentrates and plasma with riboflavin and UV light: Impact in bacterial reduction. Transfus Clin Biol 2018; 25:197-203. [PMID: 29656962 DOI: 10.1016/j.tracli.2018.03.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Accepted: 03/16/2018] [Indexed: 02/06/2023]
Abstract
OBJECTIVES Transfusion of hemocomponents is essential for clinical and surgical procedures and therefore their safety has increased. An option for pathogen reduction includes the combination of riboflavin and UV light. To our knowledge, there are no studies in Latin America that demonstrate the effectiveness of the pathogen reduction in hemocomponents. The objective of this work was to evaluate the efficiency of a pathogens reduction system in platelets concentrates (PC) and plasma. MATERIALS AND METHODS PC and plasma were contaminated with Escherichia coli, Klebsiella pneumoniae, Streptococcus pyogenes and Staphylococcus epidermidis at 104 to 106 CFU and subjected to bacterial reduction. After bacterial reduction, hemocomponents were subjected to cultivation of surviving bacteria by automated method and classical colonies quantification. Additionally, quality control testing was performed in order to confirm the integrity of platelets and coagulation laboratory values in plasma before and after bacterial reduction. RESULTS The bacterial death in PC/plasma was expressed by Logarithmic Reduction Value as follows: for both strains (E. coli and S. pyogenes) 4/4, 5/5 and 6/6; for K. pneumoniae 2.54/2.23, 2.94/2.22 and 3.44/2.98, for S. epidermidis 4/4, 3.11/5 and 3.23/4.19, for 104, 105 and 106 CFU, respectively. In PC and plasma, platelet count, pH (at 22°C), activated partial thromboplastin time (aPTT), prothrombin time (PT), fibrinogen, factor VIII and total proteins (TP) were slightly modified. CONCLUSIONS UV light with riboflavin is able to reduce an important number of pathogens in hemocomponents; however, the bacterial reduction is influenced by the nature and quantity of the pathogen.
Collapse
Affiliation(s)
- J M Bello-López
- Centro Nacional de la Transfusión Sanguínea, Av. Othón de Mendizábal 195, Zacatenco, Gustavo A. Madero, 07360 México City, Mexico; Hospital Juárez de México, Av. Instituto Politécnico Nacional 5160, Zacatenco, Gustavo A. Madero, 07360 México City, Mexico.
| | - L Delgado-Balbuena
- Centro Nacional de la Transfusión Sanguínea, Av. Othón de Mendizábal 195, Zacatenco, Gustavo A. Madero, 07360 México City, Mexico
| | - D Rojas-Huidobro
- Centro Nacional de la Transfusión Sanguínea, Av. Othón de Mendizábal 195, Zacatenco, Gustavo A. Madero, 07360 México City, Mexico
| | - J Rojo-Medina
- Centro Nacional de la Transfusión Sanguínea, Av. Othón de Mendizábal 195, Zacatenco, Gustavo A. Madero, 07360 México City, Mexico
| |
Collapse
|
5
|
Zhu L, Pan J, Wei C, Wang H, Xiang R, Zhang J, Wang D. The effectiveness of riboflavin photochemical-mediated virus inactivation and changes in protein retention in fresh-frozen plasma treated using a flow-based treatment device. Transfusion 2014; 55:100-7. [PMID: 25070346 DOI: 10.1111/trf.12775] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Revised: 05/02/2014] [Accepted: 05/23/2014] [Indexed: 12/27/2022]
Abstract
BACKGROUND A flow-based treatment device using riboflavin and ultraviolet (UV) light was developed to inactivate viruses in fresh-frozen plasma (FFP). The objective of this study was to evaluate the in vitro effectiveness of virus inactivation and changes in protein quality in FFP treated with this device. STUDY DESIGN AND METHODS FFP-contaminating viruses were treated with riboflavin and UV light using a one-pass linear flow device. The infectivity of viruses was measured using established biologic assays. Real-time polymerase chain reaction (PCR) was performed to detect damage to viral nucleotides after treatment. Treated plasma was analyzed using standard coagulation assays. RESULTS FFP treated at the UV dose of 3.6 J/cm(2) (J) exhibited a mean reduction of virus titer of more than 4 logs. The effectiveness increased significantly at higher doses. Real-time PCR showed that the cycle threshold values for both complete inactivation and virus recultivation were higher than that of the untreated sample. At doses of 3.6, 5.4, and 7.2 J, the protein recovery rates were 60.2 ± 8.6, 46.6 ± 9.4, and 28.0 ± 1.0% for fibrinogen; 67.0 ± 3.1, 57.3 ± 8.0, and 49.2 ± 3.8% for Factor VIII; 93.6 ± 2.8, 89.6 ± 6.1, and 86.5 ± 5.3% for antithrombin-III; and 72.1 ± 5.6, 59.8 ± 14.2, and 49.2 ± 8.4% for Protein C, respectively. CONCLUSION The effectiveness of virus inactivation was enhanced, but total activity of plasma factors was reduced, in a UV dose-dependent manner.
Collapse
Affiliation(s)
- Liguo Zhu
- Department of Blood Transfusion, Chinese PLA General Hospital, Beijing, China
| | | | | | | | | | | | | |
Collapse
|
6
|
Prudent M, Tissot JD, Lion N. Proteomics of blood and derived products: what’s next? Expert Rev Proteomics 2014; 8:717-37. [DOI: 10.1586/epr.11.58] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
7
|
|
8
|
Ettinger A, Miklauz MM, Hendrix BK, Bihm DJ, Maldonado-Codina G, Goodrich RP. Quality of proteins in riboflavin and UV light-treated FFP during 1year of storage at −18°C. Transfus Apher Sci 2012; 46:15-8. [DOI: 10.1016/j.transci.2011.10.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2011] [Revised: 08/11/2011] [Accepted: 10/13/2011] [Indexed: 10/15/2022]
|
9
|
Marschner S, Goodrich R. Pathogen Reduction Technology Treatment of Platelets, Plasma and Whole Blood Using Riboflavin and UV Light. Transfus Med Hemother 2011; 38:8-18. [PMID: 21779202 PMCID: PMC3132976 DOI: 10.1159/000324160] [Citation(s) in RCA: 155] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2010] [Accepted: 01/13/2011] [Indexed: 11/19/2022] Open
Abstract
Bacterial contamination and emerging infections combined with increased international travel pose a great risk to the safety of the blood supply. Tests to detect the presence of infection in a donor have a 'window period' during which infections cannot be detected but the donor may be infectious. Agents and their transmission routes need to be recognized before specific tests can be developed. Pathogen reduction of blood components represents a means to address these concerns and is a proactive approach for the prevention of transfusion-transmitted diseases. The expectation of a pathogen reduction system is that it achieves high enough levels of pathogen reduction to reduce or prevent the likelihood of disease transmission while preserving adequate cell and protein quality. In addition the system needs to be non-toxic, non-mutagenic and should be simple to use. The Mirasol® Pathogen Reduction Technology (PRT) System for Platelets and Plasma uses riboflavin (vitamin B2) plus UV light to induce damage in nucleic acid-containing agents. The system has been shown to be effective against clinically relevant pathogens and inactivates leukocytes without significantly compromising the efficacy of the product or resulting in product loss. Riboflavin is a naturally occurring vitamin with a well-known and well-characterized safety profile. The same methodology is currently under development for the treatment of whole blood, making pathogen reduction of all blood products using one system achievable. This review gives an overview of the Mirasol PRT System, summarizing the mechanism of action, toxicology profile, pathogen reduction performance and clinical efficacy of the process.
Collapse
|