1
|
Tamaki Y, Hatayama N, Fujii Y, Naito M. A compact machine perfusion device for whole blood perfusion in isolated rat liver. J Artif Organs 2024:10.1007/s10047-024-01474-8. [PMID: 39363050 DOI: 10.1007/s10047-024-01474-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Accepted: 09/19/2024] [Indexed: 10/05/2024]
Abstract
We established a compact machine perfusion system for whole blood perfusion of rat liver by making use of oxygenation filters as an artificial lung. Livers removed from rats were divided into Krebs-Henseleit (control), 50% blood (hemoglobin: 7 g/dL), and whole blood (hemoglobin: 14 g/dL) groups, then perfused (total perfusate volume: 25 ml) with a small oxygenation filter at 37 °C for 120 min. Blood or perfusate was collected over time, and blood gas and blood cell were measured. In addition, bile volume and portal venous pressure measurements were taken. In all groups, the partial pressure of oxygen was controlled to approximately 400 mmHg. Flow rates were maintained at approximately about 20-30 ml/min according to liver size. Portal venous pressure was normal in the 50% blood and whole blood groups, while lower than the reference value in the Krebs-Henseleit group. Twice as much bile was produced in the 50% blood and whole blood groups relative with the Krebs-Henseleit group. We observed no differences in hemoglobin and red blood cell levels. Lactate levels were normal in the 50% blood and whole blood groups, but were elevated in the Krebs-Henseleit group. Our compact perfusion system using oxygenation filters was able to maintain rat liver function by perfusing a small amount of extracorporeal blood. This system is simple and stable, and may contribute to the future development of machine perfusion systems.
Collapse
Affiliation(s)
- Yuki Tamaki
- Department of Anatomy, Aichi Medical University, Nagakute, Aichi, 480-1195, Japan.
| | - Naoyuki Hatayama
- Department of Anatomy, Aichi Medical University, Nagakute, Aichi, 480-1195, Japan
| | - Yutaka Fujii
- Department of Clinical Engineering and Medical Technology, Niigata University of Health and Welfare, Niigata, Japan
| | - Munekazu Naito
- Department of Anatomy, Aichi Medical University, Nagakute, Aichi, 480-1195, Japan.
| |
Collapse
|
2
|
Fukai M, Shibata K, Sakamoto S, Ishikawa T, Kawamura N, Fujiyoshi M, Fujiyoshi S, Nakamura K, Bochimoto H, Shimada S, Shimamura T, Taketomi A. Role of Heavy Water in Modified University of Wisconsin Solution for Extended Cold Storage of Rat Liver. Transplant Proc 2024; 56:1890-1895. [PMID: 39217028 DOI: 10.1016/j.transproceed.2024.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 05/30/2024] [Accepted: 06/27/2024] [Indexed: 09/04/2024]
Abstract
To resolve the critical donor shortage worldwide, enlarging the potential donor pool to include expanded criteria donors is necessary. Despite numerous attempts to establish new preservation solutions, no dramatic innovation has occurred since University of Wisconsin (UW) solution displaced Euro Collins' solution; UW solution remains the global gold standard. We previously developed a heavy water (D2O)-containing organ storage solution, Dsol, which is effective for livers subjected to extended cold storage (CS), and reported its effectiveness. Dsol is a modified UW solution; however, the substances or conditions that exhibit a synergistic or additive effect with D2O are unclear. Here we made UWD solution by removing hydroxyethyl starch (HES) from and adding 30%-D2O to UW solution, and compared the effects of these solutions. After 48 hours of CS, the livers were reperfused at 37 °C on an isolated perfused rat liver apparatus, and their perfusion kinetics, functions, and injuries were compared. In the UW group, portal vein resistance significantly increased and the oxygen consumption rate and bile production decreased; in contrast, these changes were suppressed in the UWD group. Organ expansion and liver damage progressed in both groups. These results confirmed that the removal of HES from and addition of D2O to the UW solution reduced CS-induced cellular function impairments and microcirculatory disorders. However, to reduce injury during reperfusion after CS, it is necessary to provide conditions that inhibit injury progression after reperfusion.
Collapse
Affiliation(s)
- Moto Fukai
- Gastroenterological Surgery 1, Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
| | - Kengo Shibata
- Gastroenterological Surgery 1, Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| | - Sodai Sakamoto
- Gastroenterological Surgery 1, Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| | - Takahisa Ishikawa
- Gastroenterological Surgery 1, Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| | - Norio Kawamura
- Department of Transplant Surgery, Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| | - Masato Fujiyoshi
- Gastroenterological Surgery 1, Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| | - Sunao Fujiyoshi
- Gastroenterological Surgery 1, Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| | - Kosei Nakamura
- Gastroenterological Surgery 1, Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| | - Hiroki Bochimoto
- Department of Cell Physiology, School of Medicine, The Jikei University, Tokyo, Japan
| | - Shingo Shimada
- Division of Hepato-Biliary-Pancreatic and Transplant Surgery, Asahikawa Medical University, Asahikawa, Japan
| | - Tsuyoshi Shimamura
- Division of Organ Transplantation, Hokkaido University Hospital, Sapporo, Japan
| | - Akinobu Taketomi
- Gastroenterological Surgery 1, Graduate School of Medicine, Hokkaido University, Sapporo, Japan; Department of Transplant Surgery, Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| |
Collapse
|
3
|
Asong-Fontem N, Panisello-Rosello A, Beghdadi N, Lopez A, Rosello-Catafau J, Adam R. Pre-Ischemic Hypothermic Oxygenated Perfusion Alleviates Protective Molecular Markers of Ischemia-Reperfusion Injury in Rat Liver. Transplant Proc 2022; 54:1954-1969. [PMID: 35961798 DOI: 10.1016/j.transproceed.2022.05.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 04/26/2022] [Accepted: 05/22/2022] [Indexed: 11/16/2022]
Abstract
To expand the pool of organs, hypothermic oxygenated perfusion (HOPE), one of the most promising perfusion protocols, is currently performed after cold storage (CS) at transplant centers (HOPE-END). We investigated a new timing for HOPE, hypothesizing that performing HOPE before CS (HOPE-PRE) could boost mitochondrial protection allowing the graft to better cope with the accumulation of oxidative stress during CS. We analyzed liver injuries at 3 different levels. Histologic analysis demonstrated that, compared to classical CS (CTRL), the HOPE-PRE group showed significantly less ischemic necrosis compared to CTRL vs HOPE-END. From a biochemical standpoint, transaminases were lower after 2 hours of reperfusion in the CTRL vs HOPE-PRE group, which marked decreased liver injury. qPCR analysis on 37 genes involved in ischemia-reperfusion injury revealed protection in HOPE-PRE and HOPE-END compared to CTRL mediated through similar pathways. However, the CTRL vs HOPE-PRE group demonstrated an increased transcriptional level for protective genes compared to the CTRL vs HOPE-END group. This study provides insights on novel biomarkers that could be used in the clinic to better characterize graft quality improving transplantation outcomes.
Collapse
Affiliation(s)
- Njikem Asong-Fontem
- Université Paris-Saclay, Faculté de Médecine, Unité Chronothérapie, Cancers et Transplantation, Kremlin-Bicêtre, France.
| | - Arnau Panisello-Rosello
- Experimental Hepatic Ischemia-Reperfusion Unit, Institut d'Investigacions Biomèdiques de Barcelona (IIBB), Spanish National Research Council (CSIC), Barcelona, Catalonia, Spain
| | - Nassiba Beghdadi
- Université Paris-Saclay, Faculté de Médecine, Unité Chronothérapie, Cancers et Transplantation, Kremlin-Bicêtre, France; Center Hépato-Biliaire, APHP Hôpital Universitaire Paul Brousse, Villejuif, France
| | - Alexandre Lopez
- Université Paris-Saclay, Faculté de Médecine, Unité Chronothérapie, Cancers et Transplantation, Kremlin-Bicêtre, France
| | - Joan Rosello-Catafau
- Experimental Hepatic Ischemia-Reperfusion Unit, Institut d'Investigacions Biomèdiques de Barcelona (IIBB), Spanish National Research Council (CSIC), Barcelona, Catalonia, Spain
| | - René Adam
- Université Paris-Saclay, Faculté de Médecine, Unité Chronothérapie, Cancers et Transplantation, Kremlin-Bicêtre, France; Center Hépato-Biliaire, APHP Hôpital Universitaire Paul Brousse, Villejuif, France
| |
Collapse
|
4
|
Kyuno D, Qian B, Groß W, Schäfer M, Ryschich E. Endothelium capture-based liver segment imaging using vascular endothelial growth factor receptor 2 in preclinical ex vivo models. BJS Open 2020; 4:332-341. [PMID: 31965760 PMCID: PMC7093791 DOI: 10.1002/bjs5.50253] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 11/08/2019] [Accepted: 11/20/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Near-infrared (NIR) imaging of liver segments provides substantial information for surgeons performing liver resection. It was hypothesized that ramucirumab, an endothelium-specific antibody approved by the Food and Drug Administration, could be used for liver segment imaging using the endothelium capture principle. METHODS The capture efficacy of anti-vascular endothelial growth factor receptor (VEGFR) 2 monoclonal antibodies (mAbs) and segment imaging were studied in a mouse model. Binding of ramucirumab in human and porcine tissues was studied using immunofluorescence staining. Isolated porcine liver perfusion was used to analyse the labelling and NIR imaging of selected liver segments. RESULTS VEGFR2 is well expressed on the endothelium of the smallest microvascular blood vessels in mouse, porcine and human liver tissues, as well as in human liver tumours. Perfusion of selected segments in the isolated liver model showed high capture of the anti-VEGFR2 (clone 522302) mAb and ramucirumab in mice and pigs respectively. NIR imaging of selected segments was achieved using isolated porcine liver perfusion with IRDye® 800CW-conjugated ramucirumab. CONCLUSION VEGFR2 is well expressed on the smallest microvascular blood vessels and can capture antibodies during single intravascular passages with high efficacy. The ex vivo imaging of a selected segment using endothelial capture of ramucirumab demonstrates the potential of this antibody for intraoperative navigation in liver surgery. Surgical relevance Imaging of liver segments provides substantial information for surgeons when performing liver resection. The antivascular endothelial growth factor receptor (VEGFR) 2 antibody ramucirumab conjugated with near-infrared dye could visualize selected liver segments using an endothelial capture-based approach in an isolated perfusion liver model. The ex vivo imaging of a selected segment using endothelial capture of ramucirumab demonstrates the potential of this anti-VEGFR2 antibody for intraoperative navigation in liver surgery.
Collapse
Affiliation(s)
- D. Kyuno
- Department of General, Visceral and Transplantation SurgeryUniversity Hospital HeidelbergHeidelbergGermany
- Department of Surgery, Surgical Oncology and ScienceSapporo Medical UniversitySapporoJapan
| | - B. Qian
- Department of General, Visceral and Transplantation SurgeryUniversity Hospital HeidelbergHeidelbergGermany
| | - W. Groß
- Department of General, Visceral and Transplantation SurgeryUniversity Hospital HeidelbergHeidelbergGermany
| | - M. Schäfer
- Department of General, Visceral and Transplantation SurgeryUniversity Hospital HeidelbergHeidelbergGermany
| | - E. Ryschich
- Department of General, Visceral and Transplantation SurgeryUniversity Hospital HeidelbergHeidelbergGermany
| |
Collapse
|
5
|
Yoshimoto S, Torai S, Yoshioka M, Nadahara S, Kobayashi E. Continuous Resuscitation for Porcine Liver Transplantation From Donor After Cardiac Death. Transplant Proc 2019; 51:1463-1467. [PMID: 31155180 DOI: 10.1016/j.transproceed.2019.03.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2018] [Revised: 03/11/2019] [Accepted: 03/11/2019] [Indexed: 11/24/2022]
Abstract
BACKGROUND To solve the serious donor shortage, the demand is increasing for developing a new method to use the marginal donors, including donors after cardiac death (DCD). Continuous machine perfusion from ex vivo to in situ is a novel technique to overcome warm ischemia during organ grafting as an ischemia-free transplantation. Herein, we tested orthotopic and heterotopic ischemia-free liver transplantation in pigs and evaluated the perfusion characteristics of DCD grafts from ex vivo preservation to implantation. MATERIALS AND METHODS The demonstration of ischemia-free transplantation was conducted using both orthotopic and heterotopic transplantation models. Warm ischemia time (WIT) was set at 60 minutes or 120 minutes in the DCD models. Recipients were humanely killed 3 days after transplant. Flow rates of portal vein and hepatic artery were set to 0.06 to 0.15 mL/min/g and 0.04 to 0.06 mL/min/g for the liver weight ratio, respectively. RESULTS Under the stable perfusion rate by machine perfusion, the average hepatic artery pressure of the liver graft after a WIT of 120 minutes was approximately 80 mm Hg higher than after WIT of 60 minutes. The recipient with liver graft of WIT of 60 minutes could not survive overnight. In heterotopic model, the recipient with 1 hour DCD liver survived until humanely killed. CONCLUSIONS The results of pressure monitoring in our DCD liver graft model indicate that pressures are influenced not only by thrombus formation but also by postmortem rigidity at 2 hours after cardiac death.
Collapse
Affiliation(s)
| | | | | | | | - Eiji Kobayashi
- SCREEN Holdings Co., Ltd, Kyoto, Japan; Department of Organ Fabrication, Keio University School of Medicine, Tokyo, Japan.
| |
Collapse
|
6
|
Porcine Isolated Liver Perfusion for the Study of Ischemia Reperfusion Injury: A Systematic Review. Transplantation 2019; 102:1039-1049. [PMID: 29509572 DOI: 10.1097/tp.0000000000002156] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Understanding ischemia reperfusion injury (IRI) is essential to further improve outcomes after liver transplantation (LT). Porcine isolated liver perfusion (ILP) is increasingly used to reproduce LT-associated IRI in a strictly controlled environment. However, whether ILP is a reliable substitute of LT was never validated. METHODS We systematically reviewed the current experimental setups for ILP and parameters of interest reflecting IRI. RESULTS Isolated liver perfusion was never compared with transplantation in animals. Considerable variability exists between setups, and comparative data are unavailable. Experience so far suggests that centrifugal pump(s) with continuous flow are preferred to reduce the risk of embolism. Hepatic outflow can be established by cannulation of the inferior vena cava or freely drained in an open bath. Whole blood at approximately 38°C, hematocrit of 20% or greater, and the presence of leukocytes to trigger inflammation is considered the optimal perfusate. A number of parameters related to the 4 liver compartments (hepatocyte, cholangiocyte, endothelium, immune cells) are available; however, their significance and relation to clinical outcomes is not well described. CONCLUSIONS Porcine ILP provides a reproducible model to study early IRI events. As all models, it has its limitations. A standardization of the setup would allow comparison of data and progress in the field.
Collapse
|
7
|
Qian B, Kyuno D, Schäfer M, Gross W, Mehrabi A, Ryschich E. Liver segment imaging using monocyte sequestration: a potential tool for fluorescence-guided liver surgery. Theranostics 2018; 8:6101-6110. [PMID: 30613285 PMCID: PMC6299692 DOI: 10.7150/thno.29223] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Accepted: 10/08/2018] [Indexed: 12/13/2022] Open
Abstract
Background: The accurate determination of liver segment anatomy is essential to perform liver resection without complications and to ensure long-term outcomes after this operation. There are several perioperative methods for segment identification and surgical navigation, such as intraoperative ultrasound, indigo carmine and near-infrared imaging with indocyanine green. The present study experimentally analyzed the usefulness of monocyte sequestration for liver segment labeling and imaging. Methods: Human monocytes were isolated from peripheral blood and directly or indirectly labeled with calcein or IRDye 800CW. Potential toxicity, labeling stability, and adhesion to ICAM-1 were analyzed in vitro. Monocyte sequestration in the liver microvasculature and liver segment labeling and boundary demarcation were studied using isolated mouse and pig liver perfusion and via intraportal injection in mouse liver tumor models. Results: The highest monocyte labeling efficiency was achieved using direct labeling with IRDye 800CW. Labeling was stable and did not influence cell viability. The labeled monocytes were highly sequestrated in the liver microvasculature, both after ex vivo perfusion and after injection in vivo , resulting in excellent labeling of selected liver segments and strong segment boundary demarcation. In contrast to results to a normal liver, monocyte sequestration was very low in tumor-associated blood vessels. Conclusions: The present experimental study shows that sequestration of labeled monocytes after superselective application demarcates the selected liver segment. These results illustrate potential of this technique for surgical navigation during liver surgery.
Collapse
|
8
|
Bral M, Gala-Lopez B, Bigam DL, Freed DH, Shapiro AMJ. Ex situ liver perfusion: Organ preservation into the future. Transplant Rev (Orlando) 2018; 32:132-141. [PMID: 29691119 DOI: 10.1016/j.trre.2018.03.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 03/27/2018] [Accepted: 03/27/2018] [Indexed: 12/15/2022]
Abstract
In recent years, remarkable progress has occurred in the development of technologies to support ex situ liver perfusion. Building upon extensive preclinical studies in large animal models, pilot and randomized clinical trials have been initiated, and preliminary outcomes suggest more optimal protection of both standard and extended criteria liver grafts. There currently exists an incredible opportunity and need to further refine this technology, determine appropriate viability measures to predict usable liver grafts, and to explore potent protective additive strategies to further optimize the quality of extended criteria organs. These findings will have major bearing in expanding the limited liver donor pool, and may save lives where up to a quarter of listed patients die on wait-lists. Herein we offer a brief overview of the history and current status of ex situ liver perfusion, and discuss future directions that will likely have major impact on the practice of clinical liver transplantation.
Collapse
Affiliation(s)
- Mariusz Bral
- Department of Surgery, University of Alberta, 2D4.43 Walter D MacKenzie Health Sciences Centre, 8440 112 St, Edmonton, Alberta T6G2B7, Canada; Members of the Canadian National Transplant Research Program (CNTRP), 2D4.43 Walter D MacKenzie Health Sciences Centre, 8440 112 St, Edmonton, Alberta T6G2B7, Canada.
| | - Boris Gala-Lopez
- Department of Surgery, University of Alberta, 2D4.43 Walter D MacKenzie Health Sciences Centre, 8440 112 St, Edmonton, Alberta T6G2B7, Canada; Members of the Canadian National Transplant Research Program (CNTRP), 2D4.43 Walter D MacKenzie Health Sciences Centre, 8440 112 St, Edmonton, Alberta T6G2B7, Canada.
| | - David L Bigam
- Department of Surgery, University of Alberta, 2D4.43 Walter D MacKenzie Health Sciences Centre, 8440 112 St, Edmonton, Alberta T6G2B7, Canada; Members of the Canadian National Transplant Research Program (CNTRP), 2D4.43 Walter D MacKenzie Health Sciences Centre, 8440 112 St, Edmonton, Alberta T6G2B7, Canada.
| | - Darren H Freed
- Department of Surgery, University of Alberta, 2D4.43 Walter D MacKenzie Health Sciences Centre, 8440 112 St, Edmonton, Alberta T6G2B7, Canada; Members of the Canadian National Transplant Research Program (CNTRP), 2D4.43 Walter D MacKenzie Health Sciences Centre, 8440 112 St, Edmonton, Alberta T6G2B7, Canada.
| | - A M James Shapiro
- Department of Surgery, University of Alberta, 2D4.43 Walter D MacKenzie Health Sciences Centre, 8440 112 St, Edmonton, Alberta T6G2B7, Canada; Members of the Canadian National Transplant Research Program (CNTRP), 2D4.43 Walter D MacKenzie Health Sciences Centre, 8440 112 St, Edmonton, Alberta T6G2B7, Canada.
| |
Collapse
|
9
|
Marecki H, Bozorgzadeh A, Porte RJ, Leuvenink HG, Uygun K, Martins PN. Liver ex situ machine perfusion preservation: A review of the methodology and results of large animal studies and clinical trials. Liver Transpl 2017; 23:679-695. [PMID: 28240817 DOI: 10.1002/lt.24751] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Accepted: 01/31/2017] [Indexed: 12/11/2022]
Abstract
Ex vivo machine perfusion (MP) is a promising way to better preserve livers prior to transplantation. Currently, no methodology has a verified benefit over simple cold storage. Before becoming clinically feasible, MP requires validation in models that reliably predict human performance. Such a model has been found in porcine liver, whose physiological, anatomical, and immunological characteristics closely resemble the human liver. Since the 1930s, researchers have explored MP as preservation, but only recently have clinical trials been performed. Making this technology clinically available holds the promise of expanding the donor pool through more effective preservation of extended criteria donor (ECD) livers. MP promises to decrease delayed graft function, primary nonfunction, and biliary strictures, which are all common failure modes of transplanted ECD livers. Although hypothermic machine perfusion (HMP) has become the standard for kidney ex vivo preservation, the precise settings and clinical role for liver MP have not yet been established. In research, there are 2 schools of thought: normothermic machine perfusion, closely mimicking physiologic conditions, and HMP, to maximize preservation. Here, we review the literature for porcine ex vivo MP, with an aim to summarize perfusion settings and outcomes pertinent to the clinical establishment of MP. Liver Transplantation 23 679-695 2017 AASLD.
Collapse
Affiliation(s)
- Hazel Marecki
- Transplant Division, Department of Surgery, University of Massachusetts, Worcester, MA
| | - Adel Bozorgzadeh
- Transplant Division, Department of Surgery, University of Massachusetts, Worcester, MA
| | - Robert J Porte
- Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, Groningen, the Netherlands
| | - Henri G Leuvenink
- Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, Groningen, the Netherlands
| | - Korkut Uygun
- Center of Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Paulo N Martins
- Transplant Division, Department of Surgery, University of Massachusetts, Worcester, MA
| |
Collapse
|
10
|
Vogel T, Brockmann JG, Quaglia A, Morovat A, Jassem W, Heaton ND, Coussios CC, Friend PJ. The 24-hour normothermic machine perfusion of discarded human liver grafts. Liver Transpl 2017; 23:207-220. [PMID: 27809409 DOI: 10.1002/lt.24672] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2016] [Accepted: 10/03/2016] [Indexed: 12/11/2022]
Abstract
Donor organ shortage necessitates use of less than optimal donor allografts for transplantation. The current cold storage preservation technique fails to preserve marginal donor grafts sufficiently. Evidence from large animal experiments suggests superiority of normothermic machine preservation (NMP) of liver allografts. In this study, we analyze discarded human liver grafts that underwent NMP for the extended period of 24 hours. Thirteen human liver grafts which had been discarded for transplantation were entered into this study. Perfusion was performed with an automated device using an oxygenated, sanguineous perfusion solution at normothermia. Automated control was incorporated for temperature-, flow-, and pressure-regulation as well as oxygenation. All livers were perfused for 24 hours; parameters of biochemical and synthetic liver function as well as histological parameters of liver damage were analyzed. Livers were stratified for expected viability according to the donor's medical history, procurement data, and their macroscopic appearance. Normothermic perfusion preservation of human livers for 24 hours was shown to be technically feasible. Human liver grafts, all of which had been discarded for transplantation, showed levels suggesting organ viability with respect to metabolic and synthetic liver function (to varying degrees). There was positive correlation between instantly available perfusion parameters and generally accepted predictors of posttransplant graft survival. In conclusion, NMP is feasible reliably for periods of at least 24 hours, even in highly suboptimal donor organs. Potential benefits include not only viability testing (as suggested in recent clinical implementations), but also removal of the time constraints associated with the utilization of high-risk livers, and recovery of ischemic and other preretrieval injuries (possibly by enabling therapeutic strategies during NMP). Liver Transplantation 23 207-220 2017 AASLD.
Collapse
Affiliation(s)
- Thomas Vogel
- Department of General and Visceral Surgery, University Hospital Münster, Münster, Germany
| | - Jens G Brockmann
- King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
| | - Alberto Quaglia
- Institute of Liver Studies, King's College London, London, UK
| | - Alireza Morovat
- Department of Clinical Biochemistry, Oxford University Hospitals National Health Service Trust, Oxford, UK
| | - Wayel Jassem
- Institute of Liver Studies, King's College London, London, UK
| | - Nigel D Heaton
- Institute of Liver Studies, King's College London, London, UK
| | | | - Peter J Friend
- Nuffield Department of Surgical Sciences, University of Oxford, Oxford, UK
| |
Collapse
|
11
|
Liu S, Pang Q, Zhang J, Zhai M, Liu S, Liu C. Machine perfusion versus cold storage of livers: a meta-analysis. Front Med 2016; 10:451-464. [PMID: 27837413 DOI: 10.1007/s11684-016-0474-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2015] [Accepted: 07/19/2016] [Indexed: 12/18/2022]
Abstract
Different organ preservation methods are key factors influencing the results of liver transplantation. In this study, the outcomes of experimental models receiving donation after cardiac death (DCD) livers preserved through machine perfusion (MP) or static cold storage (CS) were compared by conducting a meta-analysis. Standardized mean difference (SMD) and 95% confidence interval (CI) were calculated to compare pooled data from two animal species. Twenty-four studies involving MP preservation were included in the meta-analysis. Compared with CS preservation, MP can reduce the levels of aspartate aminotransferase (AST), alanine aminotransferase (ALT), lactate dehydrogenase (LDH), and hyaluronic acid (HA) and the changes in liver weight. By contrast, MP can enhance bile production and portal vein flow (PVF). Alkaline phosphatase (ALP) levels and histological changes significantly differed between the two preservation methods. In conclusion, MP of DCD livers is superior to CS in experimental animals.
Collapse
Affiliation(s)
- Sushun Liu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital, School of Medicine, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Qing Pang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital, School of Medicine, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Jingyao Zhang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital, School of Medicine, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Mimi Zhai
- Department of Hepatobiliary Surgery, The First Affiliated Hospital, School of Medicine, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Sinan Liu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital, School of Medicine, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Chang Liu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital, School of Medicine, Xi'an Jiaotong University, Xi'an, 710061, China.
| |
Collapse
|
12
|
Karangwa SA, Dutkowski P, Fontes P, Friend PJ, Guarrera JV, Markmann JF, Mergental H, Minor T, Quintini C, Selzner M, Uygun K, Watson CJ, Porte RJ. Machine Perfusion of Donor Livers for Transplantation: A Proposal for Standardized Nomenclature and Reporting Guidelines. Am J Transplant 2016; 16:2932-2942. [PMID: 27129409 PMCID: PMC5132023 DOI: 10.1111/ajt.13843] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 03/28/2016] [Accepted: 04/19/2016] [Indexed: 02/06/2023]
Abstract
With increasing demand for donor organs for transplantation, machine perfusion (MP) promises to be a beneficial alternative preservation method for donor livers, particularly those considered to be of suboptimal quality, also known as extended criteria donor livers. Over the last decade, numerous studies researching MP of donor livers have been published and incredible advances have been made in both experimental and clinical research in this area. With numerous research groups working on MP, various techniques are being explored, often applying different nomenclature. The objective of this review is to catalog the differences observed in the nomenclature used in the current literature to denote various MP techniques and the manner in which methodology is reported. From this analysis, we propose a standardization of nomenclature on liver MP to maximize consistency and to enable reliable comparison and meta-analyses of studies. In addition, we propose a standardized set of guidelines for reporting the methodology of future studies on liver MP that will facilitate comparison as well as clinical implementation of liver MP procedures.
Collapse
Affiliation(s)
- S. A. Karangwa
- Section of Hepatobiliary Surgery and Liver TransplantationDepartment of SurgeryUniversity of GroningenUniversity Medical Center GroningenGroningenthe Netherlands
- Surgical Research LaboratoryUniversity of GroningenUniversity Medical Center GroningenGroningenthe Netherlands
| | - P. Dutkowski
- Department of Surgery & TransplantationUniversity Hospital ZurichZurichSwitzerland
| | - P. Fontes
- Thomas E. Starzl Transplantation Institute Department of SurgeryUniversity of Pittsburgh Medical CenterPittsburghPA
- McGowan Institute of Regenerative MedicineUniversity of PittsburghPittsburghPA
| | - P. J. Friend
- Nuffield Department of SurgeryOxford Transplant CentreUniversity of OxfordChurchill HospitalOxfordUK
| | - J. V. Guarrera
- Department of SurgeryCenter for Liver Disease and TransplantationColumbia University Medical CenterNew YorkNY
| | | | - H. Mergental
- Liver UnitUniversity Hospital BirminghamBirminghamUK
| | - T. Minor
- Department of Surgical ResearchClinic for General Visceral and Transplantation SurgeryUniversity Hospital EssenEssenGermany
| | - C. Quintini
- Department of SurgeryTransplant CenterDigestive Disease InstituteCleveland Clinic FoundationClevelandOH
| | - M. Selzner
- Department of SurgeryMulti Organ Transplant ProgramToronto General HospitalTorontoONCanada
| | - K. Uygun
- Department of SurgeryCenter for Engineering in MedicineMassachusetts General HospitalHarvard Medical SchoolBostonMA
| | - C. J. Watson
- University of Cambridge Department of Surgery and the NIHR Blood and Transplant Research Unit in Organ Donation and Transplantation University of CambridgeAddenbrooke's HospitalCambridgeUK
| | - R. J. Porte
- Section of Hepatobiliary Surgery and Liver TransplantationDepartment of SurgeryUniversity of GroningenUniversity Medical Center GroningenGroningenthe Netherlands
| |
Collapse
|
13
|
Jia JJ, Zhang J, Li JH, Chen XD, Jiang L, Zhou YF, He N, Xie HY, Zhou L, Zheng SS. Influence of perfusate on liver viability during hypothermic machine perfusion. World J Gastroenterol 2015; 21:8848-8857. [PMID: 26269674 PMCID: PMC4528027 DOI: 10.3748/wjg.v21.i29.8848] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2015] [Revised: 04/12/2015] [Accepted: 06/10/2015] [Indexed: 02/07/2023] Open
Abstract
AIM: To optimize the perfusates used for hypothermic machine perfusion (HMP).
METHODS: Sprague-Dawley rats were assigned randomly to three groups (n = 12 per group) that received either saline, University of Wisconsin cold-storage solution (UW) or histidine-tryptophan-ketoglutarate solution (HTK) as the perfusate. Each group was divided into two subgroups: static cold storage (SCS) and HMP (n = 6 per subgroup). The liver graft was retrieved according to the method described by Kamada. For the SCS group, the graft was directly placed into cold perfusate (0-4 °C) for 6 h after liver isolation while the portal vein of the graft was connected to the perfusion machine for the HMP group. Then the perfusates were collected at different time points for analysis of aspartate aminotransferase (AST), alanine transaminase (ALT) and lactate dehydrogenase (LDH) levels. Liver tissues were obtained for evaluation of histology, dry/wet weight (D/W) ratio, and malondialdehyde (MDA) and adenosine-triphosphate (ATP) levels. The portal vein pressure and velocity were monitored in real time in all HMP subgroups.
RESULTS: Comparison of HMP and SCS: Regardless of the perfusate, HMP improved the architecture of donor graft in reducing the congestion around sinusoids and central vein and maintaining sinusoid lining in morphology; HMP improved liver function in terms of ALT, AST and LDH, especially during the 3-6 h period (SCS vs HMP using saline: ALT3, 225.00 ± 105.62 vs 49.50 ± 18.50, P = 0.047; LDH3, 1362.17 ± 563.30 vs 325.75 ± 147.43, P = 0.041; UW: LDH6, 2880.14 ± 948.46 vs 2135.00 ± 174.27, P = 0.049; HTK, AST6, 307.50 ± 52.95 vs 185.20 ± 20.46, P = 0.041); HMP decreased MDA level (saline, 2.79 ± 0.30 vs 1.09 ± 0.09, P = 0.008; UW, 3.01 ± 0.77 vs 1.23 ± 0.68, P = 0.005; HTK, 3.30 ± 0.52 vs 1.56 ± 0.22, P = 0.006). Comparison among HMP subgroups: HTK showed less portal vein resistance than UW and saline (vs saline, 3.41 ± 0.49 vs 5.00 ± 0.38, P < 0.001; vs UW, 3.41 ± 0.49 vs 4.52 ± 0.63, P = 0.007); UW reduced edema most efficiently (vs saline, 0.68 ± 0.02 vs 0.79 ± 0.05, P = 0.013), while HTK maintained ATP levels best (vs saline, 622.60 ± 29.11 vs 327.43 ± 44.66, P < 0.001; vs UW, 622.60 ± 29.11 vs 301.80 ± 37.68, P < 0.001).
CONCLUSION: HMP is superior to SCS in maintaining both architecture and function of liver grafts. Further, HTK was found to be the optimal perfusate for HMP.
Collapse
|
14
|
Bruinsma B, Yeh H, Özer S, Martins P, Farmer A, Wu W, Saeidi N, op den Dries S, Berendsen T, Smith R, Markmann J, Porte R, Yarmush M, Uygun K, Izamis M. Subnormothermic machine perfusion for ex vivo preservation and recovery of the human liver for transplantation. Am J Transplant 2014; 14:1400-9. [PMID: 24758155 PMCID: PMC4470578 DOI: 10.1111/ajt.12727] [Citation(s) in RCA: 148] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2013] [Revised: 02/25/2014] [Accepted: 02/26/2014] [Indexed: 01/25/2023]
Abstract
To reduce widespread shortages, attempts are made to use more marginal livers for transplantation. Many of these grafts are discarded for fear of inferior survival rates or biliary complications. Recent advances in organ preservation have shown that ex vivo subnormothermic machine perfusion has the potential to improve preservation and recover marginal livers pretransplantation. To determine the feasibility in human livers, we assessed the effect of 3 h of oxygenated subnormothermic machine perfusion (21°C) on seven livers discarded for transplantation. Biochemical and microscopic assessment revealed minimal injury sustained during perfusion. Improved oxygen uptake (1.30 [1.11-1.94] to 6.74 [4.15-8.16] mL O2 /min kg liver), lactate levels (4.04 [3.70-5.99] to 2.29 [1.20-3.43] mmol/L) and adenosine triphosphate content (45.0 [70.6-87.5] pmol/mg preperfusion to 167.5 [151.5-237.2] pmol/mg after perfusion) were observed. Liver function, reflected by urea, albumin and bile production, was seen during perfusion. Bile production increased and the composition of bile (bile salts/phospholipid ratio, pH and bicarbonate concentration) became more favorable. In conclusion, ex vivo subnormothermic machine perfusion effectively maintains liver function with minimal injury and sustains or improves various hepatobiliary parameters postischemia.
Collapse
Affiliation(s)
- B.G. Bruinsma
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA,Department of Surgery (Surgical Laboratory), Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - H. Yeh
- Transplant Center, Massachusetts General Hospital, Boston, MA, USA
| | - S Özer
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - P.N. Martins
- Organ Transplant Surgery, UMass Memorial Medical Center, Boston, MA, USA
| | - A. Farmer
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - W. Wu
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - N. Saeidi
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - S. op den Dries
- Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - T.A. Berendsen
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - R.N. Smith
- Department of Pathology, Massachusetts General Hospital, Boston, MA, USA
| | - J.F. Markmann
- Transplant Center, Massachusetts General Hospital, Boston, MA, USA
| | - R. Porte
- Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - M.L. Yarmush
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA,Department of Biomedical Engineering, Rutgers University, Piscataway, NJ, USA
| | - K. Uygun
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA,Corresponding authors Korkut Uygun, PhD , Maria-Louisa Izamis, PhD
| | - M.L. Izamis
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA,Corresponding authors Korkut Uygun, PhD , Maria-Louisa Izamis, PhD
| |
Collapse
|
15
|
Kanamoto M, Shimada M, Utsunomiya T, Imura S, Morine Y, Ikemoto T, Mori H, Hanaoka J. Impact of a new refrigerator on the preservation of hepatic grafts. Hepatol Res 2012; 42:798-805. [PMID: 22469252 DOI: 10.1111/j.1872-034x.2012.00987.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
AIM Current medical transplantation methods focus on solutions for major problems such as the shortage of donors. To overcome these issues, expanding organ preservation time has become a major concern. A new refrigerating chamber has been recently developed, which can cool the inside of a material to the required temperature by frequently sensing the temperature of both inside and surface of the materials. The purpose of this study is to evaluate the usefulness of a new refrigerating system in hepatic preservation. METHODS The liver grafts were harvested from rats and divided into two groups. Group A consisted of grafts preserved in chilled University of Wisconsin solution (UW) solution (on ice) for 24, 72 and 168 h. Group B consisted of grafts preserved in the UW solution in a new refrigerator at 4°C. RESULTS In group B, aspartate aminotransferase released into effluent after cold storage for 72 h showed a marked decrease compared to group A (P < 0.05). The levels of ammonia and lactate decreased significantly in group B (P < 0.05). In group B, the levels of adenosine triphosphate were significantly preserved after cold storage for 24 h and 72 h compared to group A (P < 0.05). Immunohistochemistry showed positive cells for heme oxygenase-1 were significantly increased in group B after cold storage. CONCLUSION This new refrigerator can improve preservation injury of hepatic grafts and may provide an innovative technique for liver transplantation.
Collapse
Affiliation(s)
- Mami Kanamoto
- Department of Surgery, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Tuckey NPL, Janssen GJA, Forster ME, Gieseg SP. In VitroPerfused Chinook Salmon (Oncorhynchus tshawytscha) Tails: A Potential Model for Studying Post-Harvest Tissue Chemistry and Metabolism in Valuable Fish Tissues. JOURNAL OF AQUATIC FOOD PRODUCT TECHNOLOGY 2012. [DOI: 10.1080/10498850.2011.589023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
17
|
Henry SD, Guarrera JV. Protective effects of hypothermic ex vivo perfusion on ischemia/reperfusion injury and transplant outcomes. Transplant Rev (Orlando) 2011; 26:163-75. [PMID: 22074785 DOI: 10.1016/j.trre.2011.09.001] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2011] [Revised: 07/08/2011] [Accepted: 09/02/2011] [Indexed: 12/14/2022]
Abstract
Hypothermic machine preservation (HMP) has been used in renal transplantation since the late 1960s with recent robust prospective, multicenter data showing lower rates of delayed graft function and improved graft survival. Although now clearly beneficial for renal transplantation, extrarenal machine perfusion has remained predominantly in preclinical investigations. Pancreatic HMP has drawn little clinical interest because HMP has been suggested to cause graft edema and congestion, which is associated with early venous thrombosis and graft failure. Early investigation showed no benefit of HMP in whole-organ pancreas transplant. One report did show that HMP increases islet cell yield after isolation. Preclinical work in liver HMP has been promising. Short- and long-term HMP has been shown to improve graft viability and reduce preservation injury, even in animal models of steatotic and donation after cardiac death. The first clinical study of liver HMP using a centrifugal dual perfusion technique showed excellent results with lower hepatocellular injury markers and no adverse perfusion-related outcomes. In addition, a dramatic attenuation of proinflammatory cytokine expression was observed. Further studies of liver HMP are planned with focus on developing a reproducible and standard protocol that will allow the widespread availability of this technology. Future research and clinical trials of novel organ preservation techniques, solutions, and interventions are likely to bring about developments that will allow further reduction of preservation-related ischemia/reperfusion injury and improved outcomes and allow safer utilization of the precious and limited resource of donor organs.
Collapse
Affiliation(s)
- Scot D Henry
- Division of Abdominal Organ Transplantation and Molecular Therapies and Organ Preservation Research Laboratory, Department of Surgery Columbia University Medical Center, New York, NY 10032-3784, USA
| | | |
Collapse
|
18
|
Abstract
PURPOSE OF REVIEW This review gives a broad overview of the key factors of ischemic injury to the liver and presents the current modifications of preservation solutions and the few strategies of biological modulation in clinical use today. RECENT FINDINGS Protective effects in human-liver transplantation were shown by methylprednisolone treatment in decreased donors, and by inhalation of a nontoxic dose of nitric oxide in recipients. In addition, recent results showed rescue of pig livers, donated after cardiac death by application of a cocktail of substances addressing several previously identified mechanisms of ischemia-reperfusion injury. SUMMARY The future of a pharmacological approach attenuating or preventing ischemia-reperfusion injury lies in a combination of drugs acting simultaneously on several steps of the injury cascades. Applying these substances during flush, before, and during implantation appears as an attractive strategy to protect extended criteria liver grafts.
Collapse
|
19
|
Vekemans K, Liu Q, Heedfeld V, Van de Vel K, Wylin T, Pirenne J, Monbaliu D. Hypothermic Liver Machine Perfusion With EKPS-1 Solution vs Aqix RS-I Solution: In Vivo Feasibility Study in a Pig Transplantation Model. Transplant Proc 2009; 41:617-21. [PMID: 19328939 DOI: 10.1016/j.transproceed.2008.12.022] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
OBJECTIVE Hypothermic machine perfusion (HMP) is superior to simple cold storage for kidney preservation. We previous observed in a porcine liver transplantation model increased tumor necrosis factor-alpha (TNF-alpha) production eventually leading to poor recipient survival after HMP using standard kidney perfusion solution (KPS-1) compared with simple cold storage. We compared two solutions for HMP preservation of the liver: enriched KPS-1 (EKPS-1) and Aqix RS-I. METHODS Pig livers were obtained after cold flushing with histidine-tryptophan-ketoglutarate solution. Subsequently, the livers were subjected to dual-vessel perfusion with two preservation solutions: EKPS-1 (n = 6) and Aqix RS-I (n = 3). After HMP preservation and transplantation, graft and recipient survival, hepatocellular damage (aspartate aminotransferase concentration), TNF-alpha production, and endothelial cell damage (hyaluronic acid clearance) were recorded. RESULTS No primary graft nonfunction was observed. Recipient survival at postoperative day 3 was similar in both groups (33%). Aspartate aminotransferase concentration measured in serum samples after reperfusion was similar in both groups. After reperfusion, TNF-alpha concentration was higher and hyaluronic acid clearance was lower in the EKPS-1 group vs the Aqix RS-I group at 60, 120, and 180 minutes (all P < .05). CONCLUSION Hypothermic machine perfusion provided adequate longer term graft survival. After reperfusion, TNF-alpha production seems to be reduced, and endothelial cell dysfunction remains pronounced with Aqix RS-1 solution compared with EKPS-1 solution.
Collapse
Affiliation(s)
- K Vekemans
- Abdominal Transplant Surgery Section, Department of Surgery, Catholic University of Leuven, Leuven, Belgium.
| | | | | | | | | | | | | |
Collapse
|
20
|
Stegemann J, Hirner A, Rauen U, Minor T. Gaseous oxygen persufflation or oxygenated machine perfusion with Custodiol-N for long-term preservation of ischemic rat livers? Cryobiology 2009; 58:45-51. [DOI: 10.1016/j.cryobiol.2008.10.127] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2008] [Revised: 10/08/2008] [Accepted: 10/08/2008] [Indexed: 02/08/2023]
|
21
|
Abstract
PURPOSE OF REVIEW To provide an update on recent developments in liver preservation through a comprehensive review of the literature. RECENT FINDINGS Comparisons of the available preservation solutions for liver transplantation based on recent trials suggest clinical equivalence. The debate continues regarding risk of biliary-tract complications. Development of new preservation solutions and agents that target specific mechanisms of steatotic and donors after cardiac death pathophysiology is showing promise in a variety of preclinical and clinical studies. Early clinical results of ischemic preconditioning are conflicting and so there is the need for additional clinical studies. The most important developments have been in the machine perfusion of the liver. New portable perfusion systems have shown promise in preclinical studies and may allow rapid evolution of clinical liver machine perfusion. The first human clinical trial is well underway with results showing safety and improved efficacy of preservation of transplanted human liver allografts. SUMMARY Liver preservation is in a period of rapid advance. In the future, a multifaceted liver-preservation strategy that integrates pharmacologic agents and hypothermic machine perfusion is likely to minimize organ injury and maximize patient outcomes. An ongoing challenge is to increase the number of innovations entering prospective and randomized clinical trials.
Collapse
|
22
|
Schreinemachers MCJM, Doorschodt BM, Florquin S, van den Bergh Weerman MA, Reitsma JB, Lai W, Sitzia M, Minor TM, Tolba RH, van Gulik TM. Improved preservation and microcirculation with POLYSOL after transplantation in a porcine kidney autotransplantation model. Nephrol Dial Transplant 2008; 24:816-24. [DOI: 10.1093/ndt/gfn559] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
|
23
|
Vekemans K, Liu Q, Pirenne J, Monbaliu D. Artificial circulation of the liver: machine perfusion as a preservation method in liver transplantation. Anat Rec (Hoboken) 2008; 291:735-40. [PMID: 18484620 DOI: 10.1002/ar.20662] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Due to the sharp increase in liver transplant candidates and the subsequent shortage of suitable donor livers, an extension of the current donor criteria is necessary. Simple cold storage, the current standard in organ preservation has proven to be insufficient to preserve extended criteria donor livers. Therefore a renewed interest grew toward alternative methods for liver preservation, such as hypothermic machine perfusion and normothermic machine perfusion. These "new" preservation methods were primarily assessed in rat models, and only a few clinically relevant large animal models have been described so far. This review will elaborate on these alternative preservation methods.
Collapse
Affiliation(s)
- Katrien Vekemans
- Abdominal Transplant Surgery, Catholic University of Leuven (KULeuven), Leuven, Belgium.
| | | | | | | |
Collapse
|
24
|
Vairetti M, Ferrigno A, Rizzo V, Boncompagni E, Carraro A, Gringeri E, Milanesi G, Barni S, Freitas I, Cillo U. Correlation between the liver temperature employed during machine perfusion and reperfusion damage: role of Ca2+. Liver Transpl 2008; 14:494-503. [PMID: 18383108 DOI: 10.1002/lt.21421] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
This study compares the effects of machine perfusion (MP) at different temperatures with simple cold storage. In addition, the role of Ca(2+) levels in the MP medium was evaluated. For MP, rat livers were perfused for 6 hours with Krebs-Henseleit (KH) solution (with 1.25 or 2.5 mM CaCl(2)) at 4 degrees C, 10 degrees C, 20 degrees C, 25 degrees C, 30 degrees C, or 37 degrees C. For cold storage, livers were perfused in situ and preserved with Celsior solution at 4 degrees C for 6 hours. The reperfusion period (2 hours at 37 degrees C) was performed under the same conditions used for MP-preserved and cold storage-preserved livers. Hepatic enzyme release, bile production, adenosine triphosphate (ATP) levels, and morphology were evaluated during MP and reperfusion. MP at 37 degrees C caused marked enzyme release; the same findings were obtained during reperfusion. By contrast, MP temperature lowering induced a significant decrease in liver damage. High levels of biliary gamma-glutamyltransferase and lactate dehydrogenase were found with MP at 4 degrees C and 10 degrees C but not with MP at 20 degrees C. When a KH-1.25 mM CaCl(2) solution was used during MP at 20 degrees C, very low enzyme release was observed and significantly lower hepatic damage was present at the end of the reperfusion period in comparison with cold storage. The same results were obtained when ruthenium red, a calcium uniporter blocker, was added to KH-2.5 mM CaCl(2). ATP levels were higher and morphology was better in liver preserved with KH-1.25 mM CaCl(2). MP at 20 degrees C with KH-1.25 mM CaCl(2) resulted in better quality liver preservation, improving hepatocyte and endothelial biliary cell survival, in comparison with cold storage. This raises the need to reconsider the temperature and calcium levels to be used during liver MP.
Collapse
Affiliation(s)
- Mariapia Vairetti
- Department of Internal Medicine and Therapeutics, University of Pavia, Pavia, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Machine perfusion preservation of the liver: a worthwhile clinical activity? Curr Opin Organ Transplant 2007; 12:224-230. [DOI: 10.1097/mot.0b013e32814e6bc2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|