1
|
Touqeer M, Esmaeilzadeh B, Meng W, Wang J, Maqbool SA, Zheng S, Junwei L, Hou Y, Lu Q. A novel STM for quality atomic resolution with piezoelectric motor of high compactness and simplicity. Ultramicroscopy 2024; 263:113983. [PMID: 38749338 DOI: 10.1016/j.ultramic.2024.113983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 03/14/2024] [Accepted: 04/25/2024] [Indexed: 06/16/2024]
Abstract
Scanning tunneling microscope (STM) is a renowned scientific tool for obtaining high-resolution atomic images of materials. Herein, we present an innovative design of the scanning unit with a compact yet powerful inertial piezoelectric motor inspired by the Spider Drive motor principle. The scanning unit mainly consists of a small 9 mm long piezoelectric tube scanner (PTS), one end of which is coaxially connected to the main sapphire body of the STM. Of particular emphasis in this design is the piezoelectric shaft (PS), constructed from piezoelectric material instead of conventional metallic or zirconium materials. The PS is a rectangular piezoelectric stack composed of two piezoelectric plates, which are elastically clamped on the inner wall of the PTS via a spring strip. The PTS and PS expand and contract independently with each other to improve the inertial force and reduce the threshold voltage. To ensure the stability of the PS and balance the stepping performance of the inertial motor, a counterweight, and a matching conical spring are fixed at the tail of the PS. This innovative design allows for the assessment of scanning unit performance by applying a driving signal, threshold voltage is 50 V at room temperature. Step sizes vary from 0.1 to 1 µm by changing the driving signal at room temperature. Furthermore, we successfully obtained atomic-resolution images of a highly oriented pyrolytic graphite (HOPG) sample and low drift rates of 23.4 pm/min and 34.6 pm/min in X-Y plane and Z direction, respectively, under ambient conditions. This small, compact STM unit has the potential for the development of a rotatable STM for use in cryogen-free magnets, and superconducting magnets.
Collapse
Affiliation(s)
- Muhammad Touqeer
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China; University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Behnam Esmaeilzadeh
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China; University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Wenjie Meng
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China; Anhui Key Laboratory of Low-Energy Quantum Materials and Devices, High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
| | - Jihao Wang
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China; Anhui Key Laboratory of Low-Energy Quantum Materials and Devices, High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
| | - Syed Asad Maqbool
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China; University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Shaofeng Zheng
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China; University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Liu Junwei
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China; University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Yubin Hou
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China; Anhui Key Laboratory of Low-Energy Quantum Materials and Devices, High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
| | - Qingyou Lu
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China; University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China; Anhui Key Laboratory of Low-Energy Quantum Materials and Devices, High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China; Anhui Laboratory of Advanced Photon Science and Technology, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
| |
Collapse
|
2
|
Esmaeilzadeh B, Touqeer M, Junwei L, Zheng S, Geng T, Hou Y, Lu Q. Atomic resolution imaging using a novel, compact and stiff scanning tunnelling microscope in cryogen-free superconducting magnet. J Microsc 2024; 294:26-35. [PMID: 38224001 DOI: 10.1111/jmi.13262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 01/02/2024] [Accepted: 01/04/2024] [Indexed: 01/16/2024]
Abstract
We present the design and performance of a novel scanning tunnelling microscope (STM) operating in a cryogen-free superconducting magnet. Our home-built STM head is compact (51.5 mm long and 20 mm in diameter) and has a single arm that provides complete openness in the scanning area between the tip and sample. The STM head consists of two piezoelectric tubes (PTs), a piezoelectric scanning tube (PST) mounted on a well-polished zirconia shaft, and a large PT housed in a sapphire tube called the motor tube. The main body of the STM head is made of tantalum. In this design, we fixed the sapphire tube to the frame with screws so that the tube's position can be changed quickly. To analyse the stiffness of the STM head unit, we identified the lowest eigenfrequencies with 3 and 4 kHz in the bending modes, 8 kHz in a torsional mode, and 9 kHz in a longitudinal mode by finite element analysis, and also measured the low drift rates in the X-Y plane and in the Z direction. The high performance of the home-built STM was demonstrated by images of the hexagonal graphite lattice at 300 K and in a sweeping magnetic field from 0 T to 9 T. Our results confirm the high stability, vibration resistance, insensitivity to high magnetic fields and the application potential of our newly developed STM for the investigation of low-frequency systems with high static support stiffness in physics, chemistry, material and biological sciences.
Collapse
Affiliation(s)
- Behnam Esmaeilzadeh
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, China
- Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui, China
| | - Muhammad Touqeer
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, China
- Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui, China
| | - Liu Junwei
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, China
- Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui, China
| | - Shaofeng Zheng
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, China
- Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui, China
| | - Tao Geng
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, China
- Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui, China
| | - Yubin Hou
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, China
- Anhui Key Laboratory of Low-Energy Quantum Materials and Devices, High Magnetic Field Laboratory, HFIPS, Chinese Academy of Sciences, Hefei, Anhui, China
| | - Qingyou Lu
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, China
- Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui, China
- Anhui Key Laboratory of Low-Energy Quantum Materials and Devices, High Magnetic Field Laboratory, HFIPS, Chinese Academy of Sciences, Hefei, Anhui, China
- Anhui Laboratory of Advanced Photon Science and Technology, University of Science and Technology of China, Hefei, Anhui, China
| |
Collapse
|
3
|
Zhang Y, Zhao K, Zheng S, Wang J, Zhang J, Feng Q, Wang Z, Gao J, Hou Y, Meng W, Lu Y, Lu Q. Glovebox-assisted magnetic force microscope for studying air-sensitive samples in a cryogen-free magnet. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:013701. [PMID: 38197772 DOI: 10.1063/5.0186587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 12/14/2023] [Indexed: 01/11/2024]
Abstract
Most known two-dimensional magnets exhibit a high sensitivity to air, making direct characterization of their domain textures technically challenging. Herein, we report on the construction and performance of a glovebox-assisted magnetic force microscope (MFM) operating in a cryogen-free magnet, realizing imaging of the intrinsic magnetic structure of water and oxygen-sensitive materials. It features a compact tubular probe for a 50 mm-diameter variable temperature insert installed in a 12 T cryogen-free magnet. A detachable sealing chamber can be electrically connected to the tail of the probe, and its pump port can be opened and closed by a vacuum manipulator located on the top of the probe. This sealing chamber enables sample loading and positioning in the glove box and MFM transfer to the magnet maintained in an inert gas atmosphere (in this case, argon and helium gas). The performance of the MFM is demonstrated by directly imaging the surface (using no buffer layer, such as h-BN) of very air-sensitive van der Waals magnetic material chromium triiodide (CrI3) samples at low temperatures as low as 5 K and high magnetic fields up to 11.9 T. The system's adaptability permits replacing the MFM unit with a scanning tunneling microscope unit, enabling high-resolution atomic imaging of air-sensitive surface samples.
Collapse
Affiliation(s)
- Yuchen Zhang
- University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Kesen Zhao
- University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
- The High Magnetic Field Laboratory of Anhui Province, Hefei, Anhui 230031, People's Republic of China
| | - Shaofeng Zheng
- University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Jihao Wang
- Anhui Key Laboratory of Low-energy Quantum Materials and Devices, High Magnetic Field Laboratory, HFIPS, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China
- The High Magnetic Field Laboratory of Anhui Province, Hefei, Anhui 230031, People's Republic of China
| | - Jing Zhang
- Anhui Key Laboratory of Low-energy Quantum Materials and Devices, High Magnetic Field Laboratory, HFIPS, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China
- The High Magnetic Field Laboratory of Anhui Province, Hefei, Anhui 230031, People's Republic of China
| | - Qiyuan Feng
- Anhui Key Laboratory of Low-energy Quantum Materials and Devices, High Magnetic Field Laboratory, HFIPS, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China
- The High Magnetic Field Laboratory of Anhui Province, Hefei, Anhui 230031, People's Republic of China
| | - Ze Wang
- The High Magnetic Field Laboratory of Anhui Province, Hefei, Anhui 230031, People's Republic of China
| | - Jianhua Gao
- Anhui Key Laboratory of Low-energy Quantum Materials and Devices, High Magnetic Field Laboratory, HFIPS, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China
- The High Magnetic Field Laboratory of Anhui Province, Hefei, Anhui 230031, People's Republic of China
| | - Yubin Hou
- Anhui Key Laboratory of Low-energy Quantum Materials and Devices, High Magnetic Field Laboratory, HFIPS, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China
- The High Magnetic Field Laboratory of Anhui Province, Hefei, Anhui 230031, People's Republic of China
| | - Wenjie Meng
- Anhui Key Laboratory of Low-energy Quantum Materials and Devices, High Magnetic Field Laboratory, HFIPS, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China
- The High Magnetic Field Laboratory of Anhui Province, Hefei, Anhui 230031, People's Republic of China
| | - Yalin Lu
- University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
- Anhui Laboratory of Advanced Photon Science and Technology, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Qingyou Lu
- University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
- Anhui Key Laboratory of Low-energy Quantum Materials and Devices, High Magnetic Field Laboratory, HFIPS, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China
- The High Magnetic Field Laboratory of Anhui Province, Hefei, Anhui 230031, People's Republic of China
- Anhui Laboratory of Advanced Photon Science and Technology, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| |
Collapse
|
4
|
Geng T, Wang J, Meng W, Zhang J, Feng Q, Hou Y, Lu Q. A Novel Atomically Resolved Scanning Tunneling Microscope Capable of Working in Cryogen-Free Superconducting Magnet. MICROMACHINES 2023; 14:637. [PMID: 36985044 PMCID: PMC10059664 DOI: 10.3390/mi14030637] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/04/2023] [Accepted: 03/09/2023] [Indexed: 06/18/2023]
Abstract
We present a novel homebuilt scanning tunneling microscope (STM) with atomic resolution integrated into a cryogen-free superconducting magnet system with a variable temperature insert. The STM head is designed as a nested structure of double piezoelectric tubes (PTs), which are connected coaxially through a sapphire frame whose top has a sample stage. A single shaft made of tantalum, with the STM tip on top, is held firmly by a spring strip inside the internal PT. The external PT drives the shaft to the tip-sample junction based on the SpiderDrive principle, and the internal PT completes the subsequent scanning and imaging work. The STM head is simple, compact, and easy to assemble. The excellent performance of the device was demonstrated by obtaining atomic-resolution images of graphite and low drift rates of 30.2 pm/min and 41.4 pm/min in the X-Y plane and Z direction, respectively, at 300K. In addition, we cooled the sample to 1.6 K and took atomic-resolution images of graphite and NbSe2. Finally, we performed a magnetic field sweep test from 0 T to 9 T at 70 K, obtaining distinct graphite images with atomic resolution under varying magnetic fields. These experiments show our newly developed STM's high stability, vibration resistance, and immunity to high magnetic fields.
Collapse
Affiliation(s)
- Tao Geng
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- University of Science and Technology of China, Hefei 230026, China
| | - Jihao Wang
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- Anhui Province Key Laboratory of Condensed Matter Physics at Extreme Conditions, High Magnetic Field Laboratory, Chinese Academy of Sciences, Hefei 230031, China
- High Magnetic Field Laboratory of Anhui Province, Hefei 230031, China
| | - Wenjie Meng
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- Anhui Province Key Laboratory of Condensed Matter Physics at Extreme Conditions, High Magnetic Field Laboratory, Chinese Academy of Sciences, Hefei 230031, China
- High Magnetic Field Laboratory of Anhui Province, Hefei 230031, China
| | - Jing Zhang
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- Anhui Province Key Laboratory of Condensed Matter Physics at Extreme Conditions, High Magnetic Field Laboratory, Chinese Academy of Sciences, Hefei 230031, China
- High Magnetic Field Laboratory of Anhui Province, Hefei 230031, China
| | - Qiyuan Feng
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- Anhui Province Key Laboratory of Condensed Matter Physics at Extreme Conditions, High Magnetic Field Laboratory, Chinese Academy of Sciences, Hefei 230031, China
- High Magnetic Field Laboratory of Anhui Province, Hefei 230031, China
| | - Yubin Hou
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- Anhui Province Key Laboratory of Condensed Matter Physics at Extreme Conditions, High Magnetic Field Laboratory, Chinese Academy of Sciences, Hefei 230031, China
- High Magnetic Field Laboratory of Anhui Province, Hefei 230031, China
| | - Qingyou Lu
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- University of Science and Technology of China, Hefei 230026, China
- Anhui Province Key Laboratory of Condensed Matter Physics at Extreme Conditions, High Magnetic Field Laboratory, Chinese Academy of Sciences, Hefei 230031, China
- High Magnetic Field Laboratory of Anhui Province, Hefei 230031, China
- Anhui Laboratory of Advanced Photon Science and Technology, University of Science and Technology of China, Hefei 230026, China
- Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei 230026, China
| |
Collapse
|
5
|
Geng T, Wang J, Meng W, Zhang J, Feng Q, Lu Y, Hou Y, Lu Q. A cryogen-free superconducting magnet based scanning tunneling microscope for liquid phase measurement. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:033705. [PMID: 37012773 DOI: 10.1063/5.0121761] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Accepted: 02/25/2023] [Indexed: 06/19/2023]
Abstract
Scanning tunneling microscopes (STMs) that work in ultra-high vacuum and low temperatures are commonly used in condensed matter physics, but an STM that works in a high magnetic field to image chemical molecules and active biomolecules in solution has never been reported. Here, we present a liquid-phase STM for use in a 10 T cryogen-free superconducting magnet. The STM head is mainly constructed with two piezoelectric tubes. A large piezoelectric tube is fixed at the bottom of a tantalum frame to perform large-area imaging. A small piezoelectric tube mounted at the free end of the large one performs high-precision imaging. The imaging area of the large piezoelectric tube is four times that of the small one. The high compactness and rigidity of the STM head make it functional in a cryogen-free superconducting magnet with huge vibrations. The performance of our homebuilt STM was demonstrated by the high-quality, atomic-resolution images of a graphite surface, as well as the low drift rates in the X-Y plane and Z direction. Furthermore, we successfully obtained atomic-resolution images of graphite in solution conditions while sweeping the field from 0 to 10 T, illustrating the new STM's immunity to magnetic fields. The sub-molecular images of active antibodies and plasmid DNA in solution conditions show the device's capability of imaging biomolecules. Our STM is suitable for studying chemical molecules and active biomolecules in high magnetic fields.
Collapse
Affiliation(s)
- Tao Geng
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
| | - Jihao Wang
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
| | - Wengjie Meng
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
| | - Jing Zhang
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
| | - Qiyuan Feng
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
| | - Yalin Lu
- University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Yubin Hou
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
| | - Qingyou Lu
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
| |
Collapse
|