1
|
Qu W, Feng Y, Xiong T, Qayum A, Ma H. Preparation, structural and functional characterization of corn peptide-chelated calcium microcapsules using synchronous dual frequency ultrasound. ULTRASONICS SONOCHEMISTRY 2024; 102:106732. [PMID: 38150958 PMCID: PMC10765482 DOI: 10.1016/j.ultsonch.2023.106732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/03/2023] [Accepted: 12/14/2023] [Indexed: 12/29/2023]
Abstract
The utilization of peptide-chelated calcium is low due to the influence of factors such as solubility, heat and digestive environmental conditions; therefore, it is crucial to protect, prolong and stabilize this nutrient in order to enhance its efficacy. This study was conducted to prepare corn peptide-chelated calcium microcapsules using β-cyclodextrin (β-CD) as the wall material through an improved ultrasonic-assisted method. The structure, solubility, thermal stability, and in vitro gastrointestinal digestion of these microcapsules were thoroughly investigated and analyzed. The microcapsules were prepared using the following recommended conditions: a chelate concentration of 5 mg/mL, a mass ratio of chelate to β-CD of 1:8 g/g, and a synchronous dual-frequency ultrasound (20/28 kHz) at a power of 75 W, a duty ratio of 20/5 s/s, and a time of 20 min. These specific parameters were carefully selected to ensure the optimal fabrication of the microcapsules. The results showed that the utilization of dual-frequency ultrasound resulted in a significant increase in both the encapsulation rate and yield, which were enhanced by 15.84 % and 15.68 %, respectively, reaching impressive values of 79.17 % and 90.60 %. Moreover, the results of the structure index analysis provided further confirmation that ultrasonic treatment had a significant impact on the structure of the microcapsules, leading to a noticeable reduction in particle size and transformation into nanoparticles. Furthermore, the microcapsules demonstrated excellent solubility within a wide pH range of 2 to 10, with solubility ranging from 93.54 % to 88.68 %. Additionally, these microcapsules exhibited remarkable thermal stability, retaining a minimum of 84.8 % of their stability when exposed to temperatures ranging from 40 to 80 °C. Moreover, during gastric and intestinal digestion, these microcapsules exhibited a high slow-release rate of 44.66 % and 51.6 %, indicating their ability to gradually release calcium contents. The inclusion of dual-frequency ultrasound in the preparation of high calcium microcapsules yielded promising outcomes. Overall, our work presents a novel method for synthesizing corn peptide-chelated calcium microcapsules with desirable properties such as good solubility, excellent thermal stability, and a significant slow-release effect. These microcapsules have the potential to serve as fortified high calcium supplements.
Collapse
Affiliation(s)
- Wenjuan Qu
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China; Institute of Food Physical Processing, Jiangsu University, Zhenjiang 212013, China.
| | - Yuhang Feng
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Ting Xiong
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Abdul Qayum
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Haile Ma
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China; Institute of Food Physical Processing, Jiangsu University, Zhenjiang 212013, China
| |
Collapse
|
2
|
Zhang D, Wang X, Lin J, Xiong Y, Lu H, Huang J, Lou X. Multi-frequency therapeutic ultrasound: A review. ULTRASONICS SONOCHEMISTRY 2023; 100:106608. [PMID: 37774469 PMCID: PMC10543167 DOI: 10.1016/j.ultsonch.2023.106608] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 09/08/2023] [Accepted: 09/18/2023] [Indexed: 10/01/2023]
Abstract
Focused ultrasound is a noninvasive, radiation-free and real-time therapeutic approach to treat deep-seated targets, which benefits numerous diseases otherwise requiring surgeries. Treatment efficiency is one of the key factors determining therapeutic outcomes, but improving it solely by increasing the total power can be limited by the performance of general ultrasound devices. To address this, multi-frequency therapeutic ultrasound, using additional ultrasound waves of different frequencies on top of the standard single-frequency wave, provides a promising method for treatment efficiency enhancement with limited power. Several applications and numerical works have demonstrated its superiority on treatment enhancement. This paper presents an overview of the mechanisms, implementations, applications and decisive parameters of the multi-frequency therapeutic ultrasound, which could help to pave the way for better understanding and further developing this technology in the future.
Collapse
Affiliation(s)
- Dong Zhang
- Department of Radiology, Chinese PLA General Hospital, Beijing, China
| | - Xiaoyu Wang
- Department of Radiology, Chinese PLA General Hospital, Beijing, China
| | - Jiaji Lin
- Department of Radiology, Chinese PLA General Hospital, Beijing, China
| | - Yongqin Xiong
- Department of Radiology, Chinese PLA General Hospital, Beijing, China
| | - Haoxuan Lu
- Department of Radiology, Chinese PLA General Hospital, Beijing, China
| | - Jiayu Huang
- Department of Radiology, Chinese PLA General Hospital, Beijing, China
| | - Xin Lou
- Department of Radiology, Chinese PLA General Hospital, Beijing, China.
| |
Collapse
|
3
|
Wang X, Zhang L, Chen L, Wang Y, Okonkwo CE, Yagoub AEGA, Wahia H, Zhou C. Application of ultrasound and its real-time monitoring of the acoustic field during processing of tofu: Parameter optimization, protein modification, and potential mechanism. Compr Rev Food Sci Food Saf 2023; 22:2747-2772. [PMID: 37161497 DOI: 10.1111/1541-4337.13161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 03/07/2023] [Accepted: 04/04/2023] [Indexed: 05/11/2023]
Abstract
Tofu is nutritious, easy to make, and popular among consumers. At present, traditional tofu production has gradually become perfect, but there are still shortcomings, such as long soaking time, serious waste of water resources, and the inability to realize orders for production at any time. Moreover, tofu production standards have not yet been clearly defined, with large differences in quality between them, which is not conducive to industrialized and large-scale production. Ultrasound has become a promising green processing technology with advantages, such as high extraction rate, short processing time, and ease of operation. This review focused on the challenges associated with traditional tofu production during soaking, grinding, and boiling soybeans. Moreover, the advantages of ultrasonic processing over traditional processing like increasing nutrient content, improving gel properties, and inhibiting the activity of microorganisms were explained. Furthermore, the quantification of acoustic fields by real-time monitoring technology was introduced to construct the theoretical correlation between ultrasonic treatments and tofu processing. It was concluded that ultrasonic treatment improved the functional properties of soybean protein, such as solubility, emulsifying properties, foamability, rheological properties, gel strength, and thermal stability. Therefore, the application of ultrasonic technology to traditional tofu processing to optimize industrial parameters is promising.
Collapse
Affiliation(s)
- Xue Wang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, China
| | - Lei Zhang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, China
| | - Li Chen
- Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, China
| | - Yang Wang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, China
| | - Clinton Emeka Okonkwo
- Department of Food Science, College of Food and Agriculture, United Arab Emirates University, Al Ain, United Arab Emirates
| | - Abu El-Gasim A Yagoub
- Department of Food Science and Nutrition, College of Food and Agricultural Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Hafida Wahia
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, China
| | - Cunshan Zhou
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, China
| |
Collapse
|
4
|
Zhang L, Wang X, Qu W, Zhang A, Wahia H, Gao X, Ma H, Zhou C. Evaluation of dual-frequency multi-angle ultrasound on physicochemical properties of tofu gel and its finished product by TOPSIS-entropy weight method. ULTRASONICS SONOCHEMISTRY 2022; 90:106196. [PMID: 36252385 PMCID: PMC9579706 DOI: 10.1016/j.ultsonch.2022.106196] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 09/19/2022] [Accepted: 10/09/2022] [Indexed: 05/25/2023]
Abstract
The effects of dual-frequency (40 + 20 kHz) and multi-angle ultrasound (0°, 30°, 45°) on the coagulation state, network structure, flavor and protein conformation of tofu gel were studied. The results showed that the gel flavor of 40 + 20 kHz 0° group was the best and fluorescence intensity was low. The gel flavor in the 40 + 20 kHz 30° group was better than the group without ultrasound, and hydrophobic interaction and disulfide bond content was the largest. Meanwhile, the degree of protein cross-link was increased. The gel in 40 + 20 kHz 45° group had tightly gel state, high thermal stability, but poor flavor. Combined with The Order Preference by Similarity to Ideal Solution (TOPSIS)-entropy weight method, the 40 + 20 kHz 30° group, was the best ultrasonic treatment of gel. It can change the interaction between proteins, promote protein cross-link, and form a uniform and dense gel network. Finally, the hardness and moisture content of finished tofu were increased significantly, and the quality was improved.
Collapse
Affiliation(s)
- Lei Zhang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China; Jiangsu Key Laboratory of Marine Bioresources and Environment, Jiangsu Ocean University, Lianyungang 222005, China; Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang 222005, China; Institute of Food Physical Processing, Jiangsu University, Zhenjiang 212013, China
| | - Xue Wang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Wenjuan Qu
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China; Institute of Food Physical Processing, Jiangsu University, Zhenjiang 212013, China.
| | - Ao Zhang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Hafida Wahia
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Xianli Gao
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Haile Ma
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China; Institute of Food Physical Processing, Jiangsu University, Zhenjiang 212013, China
| | - Cunshan Zhou
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China; Institute of Food Physical Processing, Jiangsu University, Zhenjiang 212013, China.
| |
Collapse
|
5
|
Tabatabaei ZS, Rajabi O, Nassirli H, Vejdani Noghreiyan A, Sazgarnia A. A comparative study on generating hydroxyl radicals by single and two-frequency ultrasound with gold nanoparticles and protoporphyrin IX. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2019; 42:1039-1047. [PMID: 31617155 DOI: 10.1007/s13246-019-00803-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 09/21/2019] [Indexed: 01/29/2023]
Abstract
Sonodynamic therapy (SDT) is a new manner of killing cancer cells based on the cytotoxic interactions of ultrasound with sonosensitizing agents. It is shown that gold nanoparticles (GNPs) increase the efficiency of cavitation activity of ultrasound. In this study the influence of a single and/or two frequencies of ultrasound waves to generate hydroxyl radicals (·OH) was assessed in the presence of protoporphyrin IX (PpIX) and/or GNPs. Ultrasound cavitation activity was determined by recording fluorescence signals from chemical terephthalic acid (TA) dosimeters with or without PpIX and/or GNPs at the frequencies of 0.8 and 2.4 MHz individually and aggregately. To study hydroxyl radicals, experiments were performed with and without hydroxyl radical scavengers mannitol, histidine, and sodium azide. Cavitation activity was amplified by increasing ultrasound intensity and exposure time. The cavitation activity induced by dual ultrasound frequency was remarkably higher than the summation of effects produced by individual frequencies. All three scavengers reduced the fluorescence signal level. The effect of GNPs on intensifying cavitation activity at higher frequency was greater than that of lower frequency. PpIX showed a more effective sonosensitizing property at the lower frequency. Also, estimated synergism at dual frequency irradiation was improved in the presence of GNPs. We found that GNPs increased hydroxyl radical production at 2.4 MHz and that PpIX increased hydroxyl radical production at 0.8 MHz. Dual frequency exposure was more effective than single frequency exposure. PpIX at low frequency and gold nanoparticles at high frequency both enhance sonodynamic treatment efficacy.
Collapse
Affiliation(s)
| | - Omid Rajabi
- Department of Pharmaceutical Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Hooriyeh Nassirli
- Pharmaceutical Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Atefeh Vejdani Noghreiyan
- Student Research Committee, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Medical Physics, Faculty of Medicine, University of Medical Sciences, Mashhad, Iran
| | - Ameneh Sazgarnia
- Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
6
|
Wang M, Zhou Y. Numerical investigation of the inertial cavitation threshold by dual-frequency excitation in the fluid and tissue. ULTRASONICS SONOCHEMISTRY 2018; 42:327-338. [PMID: 29429677 DOI: 10.1016/j.ultsonch.2017.11.045] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 10/18/2017] [Accepted: 11/29/2017] [Indexed: 06/08/2023]
Abstract
Inertial cavitation thresholds, which are defined as bubble growth by 2-fold from the equilibrium radius, by two types of ultrasonic excitation (at the classical single-frequency mode and dual-frequency mode) were calculated. The effect of the dual-frequency excitation on the inertial cavitation threshold in the different surrounding media (fluid and tissue) was studied, and the paramount parameters (driving frequency, amplitude ratio, phase difference, and frequency ratio) were also optimized to maximize the inertial cavitation. The numerical prediction confirms the previous experimental results that the dual-frequency excitation is capable of reducing the inertial cavitation threshold in comparison to the single-frequency one at the same output power. The dual-frequency excitation at the high frequency (i.e., 3.1 + 3.5 MHz vs. 1.1 + 1.3 MHz) is preferred in this study. The simulation results suggest that the same amplitudes of individual components, zero phase difference, and large frequency difference are beneficial for enhancing the bubble cavitation. Overall, this work may provide a theoretical model for further investigation of dual-frequency excitation and guidance of its applications for a better outcome.
Collapse
Affiliation(s)
- Mingjun Wang
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Ave., 639798, Singapore; Motor Group, R&D, ASM Pacific Technology Ltd, 3/F, Watson Centre, 16-22 Kung Yip St, Kwai Chung, Hong Kong, PR China.
| | - Yufeng Zhou
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Ave., 639798, Singapore
| |
Collapse
|
7
|
Suo D, Govind B, Zhang S, Jing Y. Numerical investigation of the inertial cavitation threshold under multi-frequency ultrasound. ULTRASONICS SONOCHEMISTRY 2018; 41:419-426. [PMID: 29137770 DOI: 10.1016/j.ultsonch.2017.10.004] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2017] [Revised: 08/02/2017] [Accepted: 10/04/2017] [Indexed: 05/24/2023]
Abstract
Through the introduction of multi-frequency sonication in High Intensity Focused Ultrasound (HIFU), enhancement of efficiency has been noted in several applications including thrombolysis, tissue ablation, sonochemistry, and sonoluminescence. One key experimental observation is that multi-frequency ultrasound can help lower the inertial cavitation threshold, thereby improving the power efficiency. However, this has not been well corroborated by the theory. In this paper, a numerical investigation on the inertial cavitation threshold of microbubbles (MBs) under multi-frequency ultrasound irradiation is conducted. The relationships between the cavitation threshold and MB size at various frequencies and in different media are investigated. The results of single-, dual and triple frequency sonication show reduced inertial cavitation thresholds by introducing additional frequencies which is consistent with previous experimental work. In addition, no significant difference is observed between dual frequency sonication with various frequency differences. This study, not only reaffirms the benefit of using multi-frequency ultrasound for various applications, but also provides a possible route for optimizing ultrasound excitations for initiating inertial cavitation.
Collapse
Affiliation(s)
- Dingjie Suo
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, United States
| | - Bala Govind
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, United States
| | - Shengqi Zhang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, United States
| | - Yun Jing
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, United States.
| |
Collapse
|
8
|
Suo D, Guo S, Lin W, Jiang X, Jing Y. Thrombolysis using multi-frequency high intensity focused ultrasound at MHz range: anin vitrostudy. Phys Med Biol 2015; 60:7403-18. [DOI: 10.1088/0031-9155/60/18/7403] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
9
|
In vitro demonstration of focused ultrasound thrombolysis using bifrequency excitation. BIOMED RESEARCH INTERNATIONAL 2014; 2014:518787. [PMID: 25243147 PMCID: PMC4163449 DOI: 10.1155/2014/518787] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2014] [Revised: 06/05/2014] [Accepted: 06/25/2014] [Indexed: 11/20/2022]
Abstract
Focused ultrasound involving inertial cavitation has been shown to be an
efficient method to induce thrombolysis without any pharmacological agent. However,
further investigation of the mechanisms involved and further optimization of the
process are still required. The present work aims at studying the relevance of a
bifrequency excitation compared to a classical monofrequency excitation to achieve
thrombolysis without any pharmacological agent. In vitro human blood clots were
placed at the focus of a piezoelectric transducer. Efficiency of the thrombolysis
was assessed by weighing each clot before and after sonication. The efficiencies of
mono- (550 kHz) and bifrequency (535 and 565 kHz) excitations were compared for
peak power ranging from 70 W to 220 W. The thrombolysis efficiency appears to be
correlated to the inertial cavitation activity quantified by passive acoustic listening.
In the conditions of the experiment, the power needed to achieve 80% of thrombolysis
with a monofrequency excitation is reduced by the half with a bifrequency excitation.
The thermal effects of bifrequency and monofrequency excitations, studied using MR
thermometry measurements in turkey muscle samples where no cavitation occurred,
did not show any difference between both types of excitations when using the same
power level.
Collapse
|
10
|
Bull V, Civale J, Rivens I, Ter Haar G. A comparison of acoustic cavitation detection thresholds measured with piezo-electric and fiber-optic hydrophone sensors. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:2406-21. [PMID: 24035410 DOI: 10.1016/j.ultrasmedbio.2013.06.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2013] [Revised: 06/03/2013] [Accepted: 06/19/2013] [Indexed: 06/02/2023]
Abstract
A Fabry-Perot interferometer fiber-optic hydrophone (FOH) was investigated for use as an acoustic cavitation detector and compared with a piezo-ceramic passive cavitation detector (PCD). Both detectors were used to measure negative pressure thresholds for broadband emissions in 3% agar and ex vivo bovine liver simultaneously. FOH-detected half- and fourth-harmonic emissions were also studied. Three thresholds were defined and investigated: (i) onset of cavitation; (ii) 100% probability of cavitation; and (iii) a time-integrated threshold where broadband signals integrated over a 3-s exposure duration, averaged over 5-10 repeat exposures, become statistically significantly greater than noise. The statistical sensitiviy of FOH broadband detection was low compared with that of the PCD (0.43/0.31 in agar/liver). FOH-detected fourth-harmonic data agreed best with PCD broadband (sensitivity: 0.95/0.94, specificity: 0.89/0.76 in agar/liver). The FOH has potential as a cavitation detector, particularly in applications where space is limited or during magnetic resonance-guided studies.
Collapse
Affiliation(s)
- Victoria Bull
- Division of Radiotherapy and Imaging, Institute of Cancer Research, Sutton, Surrey, United Kingdom; and Royal Marsden Hospital NHS Foundation Trust.
| | | | | | | |
Collapse
|
11
|
Sijia Guo, Yun Jing, Xiaoning Jiang. Temperature rise in tissue ablation using multi-frequency ultrasound. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:1699-1707. [PMID: 25004540 DOI: 10.1109/tuffc.2013.2751] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
High-intensity focused ultrasound (HIFU) is becoming an increasingly important noninvasive surgical tool, despite the challenges in temperature rise control and unwanted heating problems. In this study, experiments and simulations on tissue ablation effectiveness were performed using multi-frequency HIFU with frequency differences of more than 500 kHz (center frequencies are 950 kHz, 1.5 MHz, and 3.3 MHz). In the experiments, the temperature was recorded as chicken breast tissue was heated by single-frequency, dual-frequency, and tri-frequency HIFU configurations at controlled acoustic power and exposure time. 5% to 10% temperature rise differences were observed between single- and multi-frequency modes, indicating that multi-frequency HIFU is more effective at producing faster temperature rises. Cavitation detection tests were conducted to compare the cavitation pressure fields between single- and multi-frequency ultrasound. Moreover, simulations on single-frequency and multi-frequency acoustic fields as well as bio-heating-induced temperature fields were performed. With the comparison between experimental and simulation results, we believe that the more effective tissue ablation using multi-frequency ultrasound is likely attributed to the enhanced cavitation, a promising result for HIFU applications.
Collapse
|
12
|
N'djin WA, Burtnyk M, Bronskill M, Chopra R. Investigation of power and frequency for 3D conformal MRI-controlled transurethral ultrasound therapy with a dual frequency multi-element transducer. Int J Hyperthermia 2012; 28:87-104. [PMID: 22235788 DOI: 10.3109/02656736.2011.622343] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Transurethral ultrasound therapy uses real-time magnetic resonance (MR) temperature feedback to enable the 3D control of thermal therapy accurately in a region within the prostate. Previous canine studies showed the feasibility of this method in vivo. The aim of this study was to reduce the procedure time, while maintaining targeting accuracy, by investigating new combinations of treatment parameters. Simulations and validation experiments in gel phantoms were used, with a collection of nine 3D realistic target prostate boundaries obtained from previous preclinical studies, where multi-slice MR images were acquired with the transurethral device in place. Acoustic power and rotation rate were varied based on temperature feedback at the prostate boundary. Maximum acoustic power and rotation rate were optimised interdependently, as a function of prostate radius and transducer operating frequency. The concept of dual frequency transducers was studied, using the fundamental frequency or the third harmonic component depending on the prostate radius. Numerical modelling enabled assessment of the effects of several acoustic parameters on treatment outcomes. The range of treatable prostate radii extended with increasing power, and tended to narrow with decreasing frequency. Reducing the frequency from 8 MHz to 4 MHz or increasing the surface acoustic power from 10 to 20 W/cm(2) led to treatment times shorter by up to 50% under appropriate conditions. A dual frequency configuration of 4/12 MHz with 20 W/cm(2) ultrasound intensity exposure can treat entire prostates up to 40 cm(3) in volume within 30 min. The interdependence between power and frequency may, however, require integrating multi-parametric functions in the controller for future optimisations.
Collapse
Affiliation(s)
- William Apoutou N'djin
- Imaging Research, Sunnybrook Health Sciences Centre, and Department of Medical Biophysics, University of Toronto, Ontario, Canada.
| | | | | | | |
Collapse
|
13
|
Auboiroux V, Dumont E, Petrusca L, Viallon M, Salomir R. An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy. Phys Med Biol 2011; 56:3563-82. [PMID: 21606558 DOI: 10.1088/0031-9155/56/12/008] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
A novel architecture for a phased-array high intensity focused ultrasound (HIFU) device was investigated, aiming to increase the capabilities of electronic steering without reducing the size of the elementary emitters. The principal medical application expected to benefit from these developments is the time-effective sonication of large tumours in moving organs. The underlying principle consists of dividing the full array of transducers into multiple sub-arrays of different resonance frequencies, with the reorientation of these individual emitters, such that each sub-array can focus within a given spatial zone. To enable magnetic resonance (MR) compatibility of the device and the number of output channels from the RF generator to be halved, a passive spectral multiplexing technique was used, consisting of parallel wiring of frequency-shifted paired piezoceramic emitters with intrinsic narrow-band response. Two families of 64 emitters (circular, 5 mm diameter) were mounted, with optimum efficiency at 0.96 and 1.03 MHz, respectively. Two different prototypes of the HIFU device were built and tested, each incorporating the same two families of emitters, but differing in the shape of the rapid prototyping plastic support that accommodated the transducers (spherical cap with radius of curvature/aperture of 130 mm/150 mm and, respectively, 80 mm/110 mm). Acoustic measurements, MR-acoustic radiation force imaging (ex vivo) and MR-thermometry (ex vivo and in vivo) were used for the characterization of the prototypes. Experimental results demonstrated an augmentation of the steering range by 80% along one preferentially chosen axis, compared to a classic spherical array of the same total number of elements. The electric power density provided to the piezoceramic transducers exceeded 50 W cm(-2) CW, without circulation of coolant water. Another important advantage of the current approach is the versatility of reshaping the array at low cost.
Collapse
|
14
|
Kosar A, Sesen M, Oral O, Itah Z, Gozuacik D. Bubbly Cavitating Flow Generation and Investigation of Its Erosional Nature for Biomedical Applications. IEEE Trans Biomed Eng 2011; 58:1337-46. [DOI: 10.1109/tbme.2011.2107322] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|