Beuret S, Heriard-Dubreuil B, Martiartu NK, Jaeger M, Thiran JP. Windowed Radon Transform for Robust Speed-of-Sound Imaging With Pulse-Echo Ultrasound. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:1579-1593. [PMID: 38109237 DOI: 10.1109/tmi.2023.3343918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2023]
Abstract
In recent years, methods estimating the spatial distribution of tissue speed of sound with pulse-echo ultrasound are gaining considerable traction. They can address limitations of B-mode imaging, for instance in diagnosing fatty liver diseases. Current state-of-the-art methods relate the tissue speed of sound to local echo shifts computed between images that are beamformed using restricted transmit and receive apertures. However, the aperture limitation affects the robustness of phase-shift estimations and, consequently, the accuracy of reconstructed speed-of-sound maps. Here, we propose a method based on the Radon transform of image patches able to estimate local phase shifts from full-aperture images. We validate our technique on simulated, phantom and in-vivo data acquired on a liver and compare it with a state-of-the-art method. We show that the proposed method enhances the stability to changes of beamforming speed of sound and to a reduction of the number of insonifications. In particular, the deployment of pulse-echo speed-of-sound estimation methods onto portable ultrasound devices can be eased by the reduction of the number of insonifications allowed by the proposed method.
Collapse
|
2
|
Simson WA, Paschali M, Sideri-Lampretsa V, Navab N, Dahl JJ. Investigating pulse-echo sound speed estimation in breast ultrasound with deep learning. ULTRASONICS 2024; 137:107179. [PMID: 37939413 PMCID: PMC10842235 DOI: 10.1016/j.ultras.2023.107179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 09/30/2023] [Accepted: 10/07/2023] [Indexed: 11/10/2023]
Abstract
Ultrasound is an adjunct tool to mammography that can quickly and safely aid physicians in diagnosing breast abnormalities. Clinical ultrasound often assumes a constant sound speed to form diagnostic B-mode images. However, the components of breast tissue, such as glandular tissue, fat, and lesions, differ in sound speed. Given a constant sound speed assumption, these differences can degrade the quality of reconstructed images via phase aberration. Sound speed images can be a powerful tool for improving image quality and identifying diseases if properly estimated. To this end, we propose a supervised deep-learning approach for sound speed estimation from analytic ultrasound signals. We develop a large-scale simulated ultrasound dataset that generates representative breast tissue samples by modeling breast gland, skin, and lesions with varying echogenicity and sound speed. We adopt a fully convolutional neural network architecture trained on a simulated dataset to produce an estimated sound speed map. The simulated tissue is interrogated with a plane wave transmit sequence, and the complex-value reconstructed images are used as input for the convolutional network. The network is trained on the sound speed distribution map of the simulated data, and the trained model can estimate sound speed given reconstructed pulse-echo signals. We further incorporate thermal noise augmentation during training to enhance model robustness to artifacts found in real ultrasound data. To highlight the ability of our model to provide accurate sound speed estimations, we evaluate it on simulated, phantom, and in-vivo breast ultrasound data.
Collapse
Affiliation(s)
- Walter A Simson
- Chair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Munich, Germany; Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA.
| | - Magdalini Paschali
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
| | - Vasiliki Sideri-Lampretsa
- Institute for Artificial Intelligence and Informatics in Medicine, Technical University of Munich, Munich, Germany
| | - Nassir Navab
- Chair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Munich, Germany; Chair for Computer Aided Medical Procedures, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Jeremy J Dahl
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
| |
Collapse
|
3
|
Nagaoka R, Omura M, Hasegawa H. Investigation of a method to estimate the average speed of sound using phase variances of element signals for ultrasound compound imaging. J Med Ultrason (2001) 2024; 51:17-28. [PMID: 37947986 PMCID: PMC10954954 DOI: 10.1007/s10396-023-01378-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 09/06/2023] [Indexed: 11/12/2023]
Abstract
PURPOSE In the receive beamforming of an ultrasonography system, a B-mode image is reconstructed by assuming an average speed of sound (SoS) as a constant value. In our previous studies, we proposed a method for estimating the average SoS based on the coherence factor (CF) and the reciprocal of phase variances of element signals in delay-and-sum (DAS) beamforming. In this paper, we investigate the accuracy of estimation of the average SoS for compound imaging. METHODS For this purpose, two numerical simulations were performed with k-Wave software. Also, the estimation methods based on the CF and the reciprocal were applied to in vivo data from the common carotid artery, and B-mode images were reconstructed using the estimated average SoS. RESULTS In the first numerical simulation using an inhomogeneous phantom, the relationship between the accuracy and the transmission angles for the estimation was investigated, and the root mean squared errors (RMSEs) of estimates obtained based on the CF and the reciprocal of the phase variance were 1.25 ± 0.09, and 0.765 ± 0.17% at the transmission sequence of steering angles of (- 10°, - 5°, 0°, 5°, 10°), respectively. In the second numerical simulation using a cyst phantom, lateral resolutions were improved by reconstructing the image using the estimates obtained using the proposed strategy (reciprocal). By the proposed strategy, improvement of the continuity of the lumen-intima interface in the lateral direction was observed in the in vivo experiment. CONCLUSION Consequently, the results indicated that the proposed strategy was beneficial for estimation of the average SoS and image reconstruction.
Collapse
Affiliation(s)
- Ryo Nagaoka
- Faculty of Engineering, University of Toyama, 3190 Gofuku, Toyama, 930-8555, Japan.
| | - Masaaki Omura
- Faculty of Engineering, University of Toyama, 3190 Gofuku, Toyama, 930-8555, Japan
| | - Hideyuki Hasegawa
- Faculty of Engineering, University of Toyama, 3190 Gofuku, Toyama, 930-8555, Japan
| |
Collapse
|
4
|
Ali R, Brevett T, Zhuang L, Bendjador H, Podkowa AS, Hsieh SS, Simson W, Sanabria SJ, Herickhoff CD, Dahl JJ. Aberration correction in diagnostic ultrasound: A review of the prior field and current directions. Z Med Phys 2023; 33:267-291. [PMID: 36849295 PMCID: PMC10517407 DOI: 10.1016/j.zemedi.2023.01.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 12/17/2022] [Accepted: 01/09/2023] [Indexed: 02/27/2023]
Abstract
Medical ultrasound images are reconstructed with simplifying assumptions on wave propagation, with one of the most prominent assumptions being that the imaging medium is composed of a constant sound speed. When the assumption of a constant sound speed are violated, which is true in most in vivoor clinical imaging scenarios, distortion of the transmitted and received ultrasound wavefronts appear and degrade the image quality. This distortion is known as aberration, and the techniques used to correct for the distortion are known as aberration correction techniques. Several models have been proposed to understand and correct for aberration. In this review paper, aberration and aberration correction are explored from the early models and correction techniques, including the near-field phase screen model and its associated correction techniques such as nearest-neighbor cross-correlation, to more recent models and correction techniques that incorporate spatially varying aberration and diffractive effects, such as models and techniques that rely on the estimation of the sound speed distribution in the imaging medium. In addition to historical models, future directions of ultrasound aberration correction are proposed.
Collapse
Affiliation(s)
- Rehman Ali
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, USA
| | - Thurston Brevett
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Louise Zhuang
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Hanna Bendjador
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
| | - Anthony S Podkowa
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
| | - Scott S Hsieh
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Walter Simson
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
| | - Sergio J Sanabria
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA; University of Deusto/ Ikerbasque Basque Foundation for Science, Bilbao, Spain
| | - Carl D Herickhoff
- Department of Biomedical Engineering, University of Memphis, TN, USA
| | - Jeremy J Dahl
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA.
| |
Collapse
|
5
|
Advances in ultrasonography: image formation and quality assessment. J Med Ultrason (2001) 2021; 48:377-389. [PMID: 34669073 PMCID: PMC8578163 DOI: 10.1007/s10396-021-01140-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 08/17/2021] [Indexed: 01/01/2023]
Abstract
Delay-and-sum (DAS) beamforming is widely used for generation of B-mode images from echo signals obtained with an array probe composed of transducer elements. However, the resolution and contrast achieved with DAS beamforming are determined by the physical specifications of the array, e.g., size and pitch of elements. To overcome this limitation, adaptive imaging methods have recently been explored extensively thanks to the dissemination of digital and programmable ultrasound systems. On the other hand, it is also important to evaluate the performance of such adaptive imaging methods quantitatively to validate whether the modification of the image characteristics resulting from the developed method is appropriate. Since many adaptive imaging methods have been developed and they often alter image characteristics, attempts have also been made to update the methods for quantitative assessment of image quality. This article provides a review of recent developments in adaptive imaging and image quality assessment.
Collapse
|
6
|
Bernhardt M, Vishnevskiy V, Rau R, Goksel O. Training Variational Networks With Multidomain Simulations: Speed-of-Sound Image Reconstruction. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:2584-2594. [PMID: 32746211 DOI: 10.1109/tuffc.2020.3010186] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Speed-of-sound (SoS) has been shown as a potential biomarker for breast cancer imaging, successfully differentiating malignant tumors from benign ones. SoS images can be reconstructed from time-of-flight measurements from ultrasound images acquired using conventional handheld ultrasound transducers. Variational networks (VNs) have recently been shown to be a potential learning-based approach for optimizing inverse problems in image reconstruction. Despite earlier promising results, these methods, however, do not generalize well from simulated to acquired data, due to the domain shift. In this work, we present for the first time a VN solution for a pulse-echo SoS image reconstruction problem using diverging waves with conventional transducers and single-sided tissue access. This is made possible by incorporating simulations with varying complexity into training. We use loop unrolling of gradient descent with momentum, with an exponentially weighted loss of outputs at each unrolled iteration in order to regularize the training. We learn norms as activation functions regularized to have smooth forms for robustness to input distribution variations. We evaluate reconstruction quality on the ray-based and full-wave simulations as well as on the tissue-mimicking phantom data, in comparison with a classical iterative [limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS)] optimization of this image reconstruction problem. We show that the proposed regularization techniques combined with multisource domain training yield substantial improvements in the domain adaptation capabilities of VN, reducing the median root mean squared error (RMSE) by 54% on a wave-based simulation data set compared to the baseline VN. We also show that on data acquired from a tissue-mimicking breast phantom, the proposed VN provides improved reconstruction in 12 ms.
Collapse
|
7
|
Stähli P, Kuriakose M, Frenz M, Jaeger M. Improved forward model for quantitative pulse-echo speed-of-sound imaging. ULTRASONICS 2020; 108:106168. [PMID: 32502892 DOI: 10.1016/j.ultras.2020.106168] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 02/24/2020] [Accepted: 04/24/2020] [Indexed: 05/24/2023]
Abstract
Computed ultrasound tomography in echo mode (CUTE) allows determining the spatial distribution of speed-of-sound (SoS) inside tissue using handheld pulse-echo ultrasound (US). This technique is based on measuring the changing phase of beamformed echoes obtained under varying transmit (Tx) and/or receive (Rx) steering angles. The SoS is reconstructed by inverting a forward model describing how the spatial distribution of SoS is related to the spatial distribution of the echo phase shift. Thanks to the straight-ray approximation, this forward model is linear and can be inverted in real-time when implemented in a state-of-the art system. Here we demonstrate that the forward model must contain two features that were not taken into account so far: (a) the phase shift must be detected between pairs of Tx and Rx angles that are centred around a set of common mid-angles, and (b) it must account for an additional phase shift induced by the offset of the reconstructed position of echoes. In a phantom study mimicking hepatic and cancer imaging, we show that both features are required to accurately predict echo phase shift among different phantom geometries, and that substantially improved quantitative SoS images are obtained compared to the model that has been used so far. The importance of the new model is corroborated by a preliminary volunteer result.
Collapse
Affiliation(s)
- Patrick Stähli
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
| | - Maju Kuriakose
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
| | - Martin Frenz
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland.
| | - Michael Jaeger
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
| |
Collapse
|
8
|
Perez-Liva M, Udías JM, Camacho J, Merčep E, Deán-Ben XL, Razansky D, Herraiz JL. Speed of sound ultrasound transmission tomography image reconstruction based on Bézier curves. ULTRASONICS 2020; 103:106097. [PMID: 32078843 DOI: 10.1016/j.ultras.2020.106097] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 01/09/2020] [Accepted: 01/09/2020] [Indexed: 02/07/2023]
Abstract
Speed of Sound (SoS) maps from ultrasound tomography (UST) provide valuable quantitative information for soft tissue characterization and identification of lesions, making this technique interesting for breast cancer detection. However, due to the complexity of the processes that characterize the interaction of ultrasonic waves with matter, classic and fast tomographic algorithms such as back-projection are not suitable. Consequently, the image reconstruction process in UST is generally slow compared to other more conventional medical tomography modalities. With the aim of facilitating the translation of this technique into real clinical practice, several reconstruction algorithms are being proposed to make image reconstruction in UST to be a fast and accurate process. The geometrical acoustic approximation is often used to reconstruct SoS with less computational burden in comparison with full-wave inversion methods. In this work, we propose a simple formulation to perform on-the-flight reconstruction for UST using geometrical acoustics with refraction correction based on quadratic Bézier polynomials. Here we demonstrate that the trajectories created with these polynomials are an accurate approximation to reproduce the refracted acoustic paths connecting the emitter and receiver transducers. The method is faster than typical acquisition times in UST. Thus, it can be considered a step towards real-time reconstructions, which may contribute to its future clinical translation.
Collapse
Affiliation(s)
- Mailyn Perez-Liva
- Grupo de Física Nuclear and IPARCOS, Univ. Complutense de Madrid, CEI Moncloa, Spain; Université de Paris, PARCC, INSERM, F-75015 Paris, France.
| | - José Manuel Udías
- Grupo de Física Nuclear and IPARCOS, Univ. Complutense de Madrid, CEI Moncloa, Spain; Instituto de Investigación Biomédica, Hospital General Universitario Carlos III, Madrid, Spain
| | - Jorge Camacho
- Ultrasound Systems and Technology Group (GSTU), Spanish National Research Council (CSIC), Madrid, Spain
| | - Elena Merčep
- iThera Medical GmbH, Munich, Germany; Faculty of Medicine, Technical University of Munich, Germany
| | - Xosé Luís Deán-Ben
- Faculty of Medicine and Institute of Pharmacology and Toxicology, University of Zurich, Switzerland; Institute for Biomedical Engineering and Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Daniel Razansky
- Faculty of Medicine and Institute of Pharmacology and Toxicology, University of Zurich, Switzerland; Institute for Biomedical Engineering and Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Joaquín L Herraiz
- Grupo de Física Nuclear and IPARCOS, Univ. Complutense de Madrid, CEI Moncloa, Spain; Instituto de Investigación Biomédica, Hospital General Universitario Carlos III, Madrid, Spain
| |
Collapse
|
9
|
Breast Cancer Assessment With Pulse-Echo Speed of Sound Ultrasound From Intrinsic Tissue Reflections: Proof-of-Concept. Invest Radiol 2020; 54:419-427. [PMID: 30913054 DOI: 10.1097/rli.0000000000000553] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
PURPOSE The aim of this study was to differentiate malignant and benign solid breast lesions with a novel ultrasound (US) technique, which measures speed of sound (SoS) using standard US transducers and intrinsic tissue reflections and scattering (speckles) as internal reference. MATERIALS AND METHODS This prospective, institutional review board-approved, Health Insurance Portability and Accountability Act-compliant prospective comparison study was performed with prior written informed consent from 20 women. Ten women with histological proven breast cancer and 10 with fibroadenoma were measured. A conventional US system with a linear probe was used for SoS-US (SonixTouch; Ultrasonix, Richmond, British Columbia, Canada). Tissue speckle reflections served as a timing reference for the US signals transmitted through the breasts. Relative phase inconsistencies were detected using plane wave measurements from different angular directions, and SoS images with 0.5-mm resolution were generated using a spatial domain reconstruction algorithm. The SoS of tumors were compared with the breast density of a larger cohort of 106 healthy women. RESULTS Breast lesions show focal increments ΔSoS (meters per second) with respect to the tissue background. Peak ΔSoS values were evaluated. Breast carcinoma showed significantly higher ΔSoS than fibroadenomas ([INCREMENT]SoS > 41.64 m/s: sensitivity, 90%; specificity, 80%; area under curve, 0.910) and healthy breast tissue of different densities (area under curve, 0.938; sensitivity, 90%; specificity, 96.5%). The lesion localization in SoS-US images was consistent with B-mode imaging and repeated SoS-US measurements were reproducible. CONCLUSIONS Using SoS-US, based on conventional US and tissue speckles as timing reference, breast carcinoma showed significantly higher SoS values than fibroadenoma and healthy breast tissue of different densities. The SoS presents a promising technique for differentiating solid breast lesions.
Collapse
|
10
|
Podkowa AS, Oelze ML. The convolutional interpretation of registration-based plane wave steered pulse-echo local sound speed estimators. Phys Med Biol 2020; 65:025003. [PMID: 31822647 DOI: 10.1088/1361-6560/ab6071] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Pulse-echo reconstruction of sound speed has long been considered a difficult problem within the domain of quantitative biomedical ultrasound. However, recent results (Jaeger 2015 Ultrasound Med. Biol. 41 235-50; Jaeger and Frenz 2015 Ultrasonics 62 299-304; Jaeger et al 2015 Phys. Med. Biol. 60 4497-515) have demonstrated that pulse-echo reconstructions of sound speed are achievable by exploiting correlations in post-beamformed data from steered, plane-wave excitations in the presence of diffuse scatterers. Despite these recent advances, a coherent theoretical imaging framework for describing the approach and results is lacking in the literature. In this work, the problem of sound speed reconstruction using steered, plane-wave excitations is reformulated as a truncated convolutional problem, and the theoretical implications of this reformulation are explored. Additionally, a matrix-free algorithm is proposed that leverages the computational and storage advantages of the fast Fourier transform (FFT) while simultaneously avoiding FFT wraparound artifacts. In particular, the storage constraints of the approach are reduced down from [Formula: see text] to [Formula: see text] over full matrix reconstruction, making this approach a better candidate for large reconstructions on clinical machines. This algorithm was then tested in the open source simulation package k-Wave to assess its robustness to modeling error and resolution reduction was demonstrated under full-wave propagation conditions relative to ideal straight-ray simulations. The method was also validated in a phantom experiment.
Collapse
|
11
|
Sanabria SJ, Ozkan E, Rominger M, Goksel O. Spatial domain reconstruction for imaging speed-of-sound with pulse-echo ultrasound: simulation and in vivo study. Phys Med Biol 2018; 63:215015. [PMID: 30365398 DOI: 10.1088/1361-6560/aae2fb] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Despite many uses of ultrasound, some pathologies such as breast cancer still cannot reliably be diagnosed in either conventional B-mode ultrasound imaging nor with more recent ultrasound elastography methods. Speed-of-sound (SoS) is a quantitative imaging biomarker, which is sensitive to structural changes due to pathology, and hence could facilitate diagnosis. Full-angle ultrasound computed tomography (USCT) was proposed to obtain spatially-resolved SoS images, however, its water-bath setup involves practical limitations. To increase clinical utility and for widespread use, recently, a limited-angle Fourier-domain SoS reconstruction was proposed, however, it suffers from significant image reconstruction artifacts. In this work, we present a SoS reconstruction strategy, where the forward problem is formulated using differential time-of-flight measurements based on apparent displacements along different ultrasound wave propagation paths, and the inverse problem is solved in spatial-domain using a proposed total-variation scheme with spatially-varying anisotropic weighting to compensate for geometric bias from limited angle imaging setup. This is shown to be robust to missing displacement data and easily allow for incorporating any prior geometric information. In numerical simulations, SoS values in inclusions are accurately reconstructed with 90% accuracy up to a noise level of 50%. With respect to Fourier-domain reconstruction, our proposed method improved contrast ratio from 0.37 to 0.67 for even high noise levels such as 50%. Numerical full-wave simulation and our preliminary in vivo results illustrate the clinical applicability of our method in a breast cancer imaging setting. Our proposed method requires single-sided access to the tissue and can be implemented as an add-on to conventional ultrasound equipment, applicable to a range of transducers and applications.
Collapse
Affiliation(s)
- Sergio J Sanabria
- Computed-assisted Applications in Medicine Group, ETH Zurich, Zurich, Switzerland. Both first authors contributed equally
| | | | | | | |
Collapse
|
12
|
Imbault M, Dioguardi Burgio M, Faccinetto A, Ronot M, Bendjador H, Deffieux T, Triquet EO, Rautou PE, Castera L, Gennisson JL, Vilgrain V, Tanter M. Ultrasonic fat fraction quantification using in vivo adaptive sound speed estimation. ACTA ACUST UNITED AC 2018; 63:215013. [DOI: 10.1088/1361-6560/aae661] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Marion Imbault
- Institut Langevin, ESPCI Paris, PSL Research University, CNRS UMR 7587, INSERM U979, Paris, France. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Hyun J, Kim YT, Doh I, Ahn B, Baik K, Kim SH. Realization of an ultrathin acoustic lens for subwavelength focusing in the megasonic range. Sci Rep 2018; 8:9131. [PMID: 29904152 PMCID: PMC6002413 DOI: 10.1038/s41598-018-27312-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Accepted: 05/23/2018] [Indexed: 11/09/2022] Open
Abstract
In this study, we report the first experimental realization of an ultrathin (0.14λ, λ = 1.482 mm means wavelength at 1 MHz in the water medium) subwavelength focusing acoustic lens that can surpass the Rayleigh diffraction limit (0.61λ/NA, NA means numerical aperture). It is termed a Super-Oscillatory Acoustic Lens (SOAL), and it operates in the megasonic range. The SOAL represents an interesting feature allowing the achievement of subwavelength focusing without the need to operate in close proximity to the object to be imaged. The optimal layout of the SOAL is obtained by utilizing a systematic design approach, referred to here as topology optimization. To this end, the optimization formulation is newly defined. The optimized SOAL is fabricated using a photo-etching process and its subwavelength focusing performance is verified experimentally via an acoustic intensity measurement system. From these measurements, we found that the proposed optimized SOAL can achieve superior focusing features with a Full Width at Half Maximum (FWHM) of ~0.40λ/NA ≃ 0.84 mm (for our SOAL, NA = 0.707) with the transmission efficiency of 26.5%.
Collapse
Affiliation(s)
- Jaeyub Hyun
- Center for Medical Convergence Metrology, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea
| | - Yong Tae Kim
- Center for Medical Convergence Metrology, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea. .,Department of Medical Physics, Korea University of Science and Technology, 176 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea.
| | - Il Doh
- Center for Medical Convergence Metrology, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea.,Department of Medical Physics, Korea University of Science and Technology, 176 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea
| | - Bongyoung Ahn
- Center for Medical Convergence Metrology, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea.,Department of Medical Physics, Korea University of Science and Technology, 176 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea
| | - Kyungmin Baik
- Center for Medical Convergence Metrology, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea
| | - Se-Hwa Kim
- Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea.,Department of Medical Physics, Korea University of Science and Technology, 176 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea
| |
Collapse
|
14
|
Imbault M, Faccinetto A, Osmanski BF, Tissier A, Deffieux T, Gennisson JL, Vilgrain V, Tanter M. Robust sound speed estimation for ultrasound-based hepatic steatosis assessment. Phys Med Biol 2017; 62:3582-3598. [PMID: 28225357 DOI: 10.1088/1361-6560/aa6226] [Citation(s) in RCA: 89] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Hepatic steatosis is a common condition, the prevalence of which is increasing along with non-alcoholic fatty liver disease (NAFLD). Currently, the most accurate noninvasive imaging method for diagnosing and quantifying hepatic steatosis is MRI, which estimates the proton-density fat fraction (PDFF) as a measure of fractional fat content. However, MRI suffers several limitations including cost, contra-indications and poor availability. Although conventional ultrasound is widely used by radiologists for hepatic steatosis assessment, it remains qualitative and operator dependent. Interestingly, the speed of sound within soft tissues is known to vary slightly from muscle (1.575 mm · µs-1) to fat (1.450 mm · µs-1). Building upon this fact, steatosis could affect liver sound speed when the fat content increases. The main objectives of this study are to propose a robust method for sound speed estimation (SSE) locally in the liver and to assess its accuracy for steatosis detection and staging. This technique was first validated on two phantoms and SSE was assessed with a precision of 0.006 and 0.003 mm · µs-1 respectively for the two phantoms. Then a preliminary clinical trial (N = 17 patients) was performed. SSE results was found to be highly correlated with MRI proton density fat fraction (R 2 = 0.69) and biopsy (AUROC = 0.952) results. This new method based on the assessment of spatio-temporal properties of the local speckle noise for SSE provides an efficient way to diagnose and stage hepatic steatosis.
Collapse
Affiliation(s)
- Marion Imbault
- Institut Langevin, ESPCI Paris, PSL Research University, CNRS UMR7587, INSERM U979, Paris, France. Université Paris Diderot, Paris, Île-de-France, France
| | | | | | | | | | | | | | | |
Collapse
|