1
|
Scicolone R, Vacca S, Pisu F, Benson JC, Nardi V, Lanzino G, Suri JS, Saba L. Radiomics and artificial intelligence: General notions and applications in the carotid vulnerable plaque. Eur J Radiol 2024; 176:111497. [PMID: 38749095 DOI: 10.1016/j.ejrad.2024.111497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 04/14/2024] [Accepted: 05/03/2024] [Indexed: 06/17/2024]
Abstract
Carotid atherosclerosis plays a substantial role in cardiovascular morbidity and mortality. Given the multifaceted impact of this disease, there has been increasing interest in harnessing artificial intelligence (AI) and radiomics as complementary tools for the quantitative analysis of medical imaging data. This integrated approach holds promise not only in refining medical imaging data analysis but also in optimizing the utilization of radiologists' expertise. By automating time consuming tasks, AI allows radiologists to focus on more pertinent responsibilities. Simultaneously, the capacity of AI in radiomics to extract nuanced patterns from raw data enhances the exploration of carotid atherosclerosis, advancing efforts in terms of (1) early detection and diagnosis, (2) risk stratification and predictive modeling, (3) improving workflow efficiency, and (4) contributing to advancements in research. This review provides an overview of general concepts related to radiomics and AI, along with their application in the field of carotid vulnerable plaque. It also offers insights into various research studies conducted on this topic across different imaging techniques.
Collapse
Affiliation(s)
- Roberta Scicolone
- Department of Radiology, Azienda Ospedaliero-Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, Cagliari, Italy
| | - Sebastiano Vacca
- University of Cagliari, School of Medicine and Surgery, Cagliari, Italy
| | - Francesco Pisu
- Department of Radiology, Azienda Ospedaliero-Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, Cagliari, Italy
| | - John C Benson
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Valentina Nardi
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | | | - Jasjit S Suri
- Stroke Monitoring and Diagnostic Division, AtheroPoint™, Roseville, CA, USA
| | - Luca Saba
- Department of Radiology, Azienda Ospedaliero-Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, Cagliari, Italy.
| |
Collapse
|
2
|
Deep-Sea Seabed Sediment Classification Using Finely Processed Multibeam Backscatter Intensity Data in the Southwest Indian Ridge. REMOTE SENSING 2022. [DOI: 10.3390/rs14112675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
In 2007, China discovered a hydrothermal anomaly in the Longqi hydrothermal area of the Southwest Indian Ridge. It was the first seabed hydrothermal area discovered in the ultraslow spreading ocean ridge in the world. Understanding the types of seabed sediments in this area is critical for studying the typical topography and geological characteristics of deep-sea seabed hydrothermal areas. The traditional classification of deep-seabed sediments adopts box sampling or gravity column sampling and identifies the types of seabed sediments through laboratory analysis. However, this classification method has some shortcomings, such as the presence of discrete sampling data points and the failure of full-coverage detection. The geological sampling in deep-sea areas is particularly inefficient. Hence, in this study, the EM122 multibeam sonar data collected in the Longqi hydrothermal area, Southwest Indian Ridge, in April 2019 are used to analyze multibeam backscatter intensity. Considering various errors in the complex deep-sea environment, obtaining backscatter intensity data can truly reflect seabed sediment types. Through unsupervised and supervised classification, the seabed sediment classification in the Longqi hydrothermal area was studied. The results showed that the accuracy of supervised classification is higher than that of unsupervised classification. Thus, unsupervised classification is primarily used for roughly classifying sediment types without on-site geological sampling. Combining the genetic algorithm (GA) and the support vector machine (SVM) neural network, deep-sea sediment types, such as deep-sea clay and calcareous ooze, can be identified rapidly and efficiently. Based on comparative analysis results, the classification accuracy of the GA-SVM neural network is higher than that of the SVM neural network, and it can be effectively applied to the high-precision classification and recognition of deep-sea sediments. In this paper, we demonstrate the fine-scale morphology and surface sediment structure characteristics of the deep-sea seafloor by finely processing high-precision deep-sea multibeam backscatter intensity data. This research can provide accurate seabed topography and sediment data for the exploration of deep-sea hydrothermal resources and the assessment of benthic habitats in deep-sea hydrothermal areas.
Collapse
|
3
|
Sanagala SS, Nicolaides A, Gupta SK, Koppula VK, Saba L, Agarwal S, Johri AM, Kalra MS, Suri JS. Ten Fast Transfer Learning Models for Carotid Ultrasound Plaque Tissue Characterization in Augmentation Framework Embedded with Heatmaps for Stroke Risk Stratification. Diagnostics (Basel) 2021; 11:2109. [PMID: 34829456 PMCID: PMC8622690 DOI: 10.3390/diagnostics11112109] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/03/2021] [Accepted: 11/09/2021] [Indexed: 12/24/2022] Open
Abstract
Background and Purpose: Only 1-2% of the internal carotid artery asymptomatic plaques are unstable as a result of >80% stenosis. Thus, unnecessary efforts can be saved if these plaques can be characterized and classified into symptomatic and asymptomatic using non-invasive B-mode ultrasound. Earlier plaque tissue characterization (PTC) methods were machine learning (ML)-based, which used hand-crafted features that yielded lower accuracy and unreliability. The proposed study shows the role of transfer learning (TL)-based deep learning models for PTC. Methods: As pertained weights were used in the supercomputer framework, we hypothesize that transfer learning (TL) provides improved performance compared with deep learning. We applied 11 kinds of artificial intelligence (AI) models, 10 of them were augmented and optimized using TL approaches-a class of Atheromatic™ 2.0 TL (AtheroPoint™, Roseville, CA, USA) that consisted of (i-ii) Visual Geometric Group-16, 19 (VGG16, 19); (iii) Inception V3 (IV3); (iv-v) DenseNet121, 169; (vi) XceptionNet; (vii) ResNet50; (viii) MobileNet; (ix) AlexNet; (x) SqueezeNet; and one DL-based (xi) SuriNet-derived from UNet. We benchmark 11 AI models against our earlier deep convolutional neural network (DCNN) model. Results: The best performing TL was MobileNet, with accuracy and area-under-the-curve (AUC) pairs of 96.10 ± 3% and 0.961 (p < 0.0001), respectively. In DL, DCNN was comparable to SuriNet, with an accuracy of 95.66% and 92.7 ± 5.66%, and an AUC of 0.956 (p < 0.0001) and 0.927 (p < 0.0001), respectively. We validated the performance of the AI architectures with established biomarkers such as greyscale median (GSM), fractal dimension (FD), higher-order spectra (HOS), and visual heatmaps. We benchmarked against previously developed Atheromatic™ 1.0 ML and showed an improvement of 12.9%. Conclusions: TL is a powerful AI tool for PTC into symptomatic and asymptomatic plaques.
Collapse
Affiliation(s)
- Skandha S. Sanagala
- CSE Department, CMR College of Engineering & Technology, Hyderabad 501401, TS, India; (S.S.S.); (V.K.K.)
- CSE Department, Bennett University, Greater Noida 203206, UP, India;
| | - Andrew Nicolaides
- Vascular Screening and Diagnostic Centre, University of Nicosia, Nicosia 1700, Cyprus;
| | - Suneet K. Gupta
- CSE Department, Bennett University, Greater Noida 203206, UP, India;
| | - Vijaya K. Koppula
- CSE Department, CMR College of Engineering & Technology, Hyderabad 501401, TS, India; (S.S.S.); (V.K.K.)
| | - Luca Saba
- Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), 10015 Cagliari, Italy;
| | | | - Amer M. Johri
- Division of Cardiology, Queen’s University, Kingston, ON K7L 3N6, Canada;
| | - Manudeep S. Kalra
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA;
| | - Jasjit S. Suri
- Stroke Diagnostic and Monitoring Division, AtheroPoint™ LLC, Roseville, CA 95661, USA
| |
Collapse
|
4
|
Saba L, Sanagala SS, Gupta SK, Koppula VK, Johri AM, Khanna NN, Mavrogeni S, Laird JR, Pareek G, Miner M, Sfikakis PP, Protogerou A, Misra DP, Agarwal V, Sharma AM, Viswanathan V, Rathore VS, Turk M, Kolluri R, Viskovic K, Cuadrado-Godia E, Kitas GD, Sharma N, Nicolaides A, Suri JS. Multimodality carotid plaque tissue characterization and classification in the artificial intelligence paradigm: a narrative review for stroke application. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1206. [PMID: 34430647 PMCID: PMC8350643 DOI: 10.21037/atm-20-7676] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Accepted: 02/25/2021] [Indexed: 12/12/2022]
Abstract
Cardiovascular disease (CVD) is one of the leading causes of morbidity and mortality in the United States of America and globally. Carotid arterial plaque, a cause and also a marker of such CVD, can be detected by various non-invasive imaging modalities such as magnetic resonance imaging (MRI), computer tomography (CT), and ultrasound (US). Characterization and classification of carotid plaque-type in these imaging modalities, especially into symptomatic and asymptomatic plaque, helps in the planning of carotid endarterectomy or stenting. It can be challenging to characterize plaque components due to (I) partial volume effect in magnetic resonance imaging (MRI) or (II) varying Hausdorff values in plaque regions in CT, and (III) attenuation of echoes reflected by the plaque during US causing acoustic shadowing. Artificial intelligence (AI) methods have become an indispensable part of healthcare and their applications to the non-invasive imaging technologies such as MRI, CT, and the US. In this narrative review, three main types of AI models (machine learning, deep learning, and transfer learning) are analyzed when applied to MRI, CT, and the US. A link between carotid plaque characteristics and the risk of coronary artery disease is presented. With regard to characterization, we review tools and techniques that use AI models to distinguish carotid plaque types based on signal processing and feature strengths. We conclude that AI-based solutions offer an accurate and robust path for tissue characterization and classification for carotid artery plaque imaging in all three imaging modalities. Due to cost, user-friendliness, and clinical effectiveness, AI in the US has dominated the most.
Collapse
Affiliation(s)
- Luca Saba
- Department of Radiology, Azienda Ospedaliero Universitaria (AOU), Cagliari, Italy
| | - Skandha S. Sanagala
- CSE Department, CMR College of Engineering & Technology, Hyderabad, India
- CSE Department, Bennett University, Greater Noida, UP, India
| | - Suneet K. Gupta
- CSE Department, Bennett University, Greater Noida, UP, India
| | - Vijaya K. Koppula
- CSE Department, CMR College of Engineering & Technology, Hyderabad, India
| | - Amer M. Johri
- Department of Medicine, Division of Cardiology, Queen’s University, Kingston, Ontario, Canada
| | - Narendra N. Khanna
- Department of Cardiology, Indraprastha APOLLO Hospitals, New Delhi, India
| | - Sophie Mavrogeni
- Cardiology Clinic, Onassis Cardiac Surgery Center, Athens, Greece
| | - John R. Laird
- Heart and Vascular Institute, Adventist Health St. Helena, St Helena, CA, USA
| | - Gyan Pareek
- Minimally Invasive Urology Institute, Brown University, Providence, Rhode Island, USA
| | - Martin Miner
- Men’s Health Center, Miriam Hospital Providence, Rhode Island, USA
| | | | - Athanasios Protogerou
- Department of Cardiovascular Prevention, National and Kapodistrian University of Athens, Athens, Greece
| | - Durga P. Misra
- Department of Clinical Immunology and Rheumatology, SGPGIMS, Lucknow, India
| | - Vikas Agarwal
- Department of Clinical Immunology and Rheumatology, SGPGIMS, Lucknow, India
| | - Aditya M. Sharma
- Division of Cardiovascular Medicine, University of Virginia, VA, USA
| | - Vijay Viswanathan
- MV Hospital for Diabetes & Professor M Viswanathan Diabetes Research Centre, Chennai, India
| | | | - Monika Turk
- The Hanse-Wissenschaftskolleg Institute for Advanced Study, Delmenhorst, Germany
| | | | | | | | - George D. Kitas
- R & D Academic Affairs, Dudley Group NHS Foundation Trust, Dudley, UK
| | - Neeraj Sharma
- Department of Biomedical Engineering, IIT-BHU, Banaras, UP, India
| | - Andrew Nicolaides
- Vascular Screening and Diagnostic Centre, University of Nicosia, Nicosia, Cyprus
| | - Jasjit S. Suri
- Stroke Monitoring and Diagnostic Division, AtheroPoint™, Roseville, CA, USA
| |
Collapse
|
5
|
Zamzmi G, Hsu LY, Li W, Sachdev V, Antani S. Harnessing Machine Intelligence in Automatic Echocardiogram Analysis: Current Status, Limitations, and Future Directions. IEEE Rev Biomed Eng 2021; 14:181-203. [PMID: 32305938 PMCID: PMC8077725 DOI: 10.1109/rbme.2020.2988295] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Echocardiography (echo) is a critical tool in diagnosing various cardiovascular diseases. Despite its diagnostic and prognostic value, interpretation and analysis of echo images are still widely performed manually by echocardiographers. A plethora of algorithms has been proposed to analyze medical ultrasound data using signal processing and machine learning techniques. These algorithms provided opportunities for developing automated echo analysis and interpretation systems. The automated approach can significantly assist in decreasing the variability and burden associated with manual image measurements. In this paper, we review the state-of-the-art automatic methods for analyzing echocardiography data. Particularly, we comprehensively and systematically review existing methods of four major tasks: echo quality assessment, view classification, boundary segmentation, and disease diagnosis. Our review covers three echo imaging modes, which are B-mode, M-mode, and Doppler. We also discuss the challenges and limitations of current methods and outline the most pressing directions for future research. In summary, this review presents the current status of automatic echo analysis and discusses the challenges that need to be addressed to obtain robust systems suitable for efficient use in clinical settings or point-of-care testing.
Collapse
|
6
|
Zhu S, Wen C, Bai D, Gao M. Diagnostic efficacy of intravascular ultrasound combined with Gd 2O 3-EPL contrast agent for patients with atherosclerosis. Exp Ther Med 2020; 20:136. [PMID: 33082868 PMCID: PMC7557720 DOI: 10.3892/etm.2020.9265] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 08/16/2019] [Indexed: 12/23/2022] Open
Abstract
Atherosclerosis is a cardiovascular disease that is pathologically associated with the growth of atherosclerotic plaques and vascular vulnerability. Intravascular ultrasound (IVUS) has been used to evaluate and treat cardiovascular diseases. Accumulating evidence has demonstrated that Gd2O3-doped nanoparticles contrast can be applied for the diagnosis of human diseases. In the present study, eplerenone (EPL), a mineralocorticoid receptor antagonist, was first doped with Gd2O3 nanoparticles (Gd2O3-EPL), following which its diagnostic efficacy for use in IVUS measurements (Gd2O3-EPL-IVUS) was evaluated for patients suspected with atherosclerosis. Gd2O3-EPL-IVUS presented with higher accuracy and sensitivity compared with IVUS in diagnosing 188 patients with suspected atherosclerosis. Gd2O3-EPL-IVUS exhibited stronger signals associated with plaque morphology compared with aloe IVUS for patients with atherosclerosis. In addition, Gd2O3-EPL-IVUS application resulted in clearer arterial plaque images compared with IVUS by binding mineralocorticoid receptors. Atherosclerosis was subsequently confirmed in all patients using computerized tomography-coronary angiography. Gd2O3-EPL-IVUS showed more accuracy in measuring vessel size, plaque burden and minimal lumen area compared with IVUS analysis alone. In conclusion, these outcomes suggest that Gd2O3-EPL-IVUS is a reliable tool for the evaluation of coronary lesions in patients with atherosclerosis.
Collapse
Affiliation(s)
- Shuangli Zhu
- Department of Ultrasonic Medicine, Beijing Royal Integrative Medicine Hospital, Beijing 102206, P.R. China
- Department of Ultrasonic Medicine, Peking University International Hospital, Beijing 102206, P.R. China
| | - Chaoyang Wen
- Department of Ultrasonic Medicine, Peking University International Hospital, Beijing 102206, P.R. China
| | - Dongxue Bai
- Department of Ultrasonic Medicine, Peking University International Hospital, Beijing 102206, P.R. China
| | - Meiying Gao
- Department of Ultrasonic Medicine, Peking University International Hospital, Beijing 102206, P.R. China
| |
Collapse
|
7
|
Skandha SS, Gupta SK, Saba L, Koppula VK, Johri AM, Khanna NN, Mavrogeni S, Laird JR, Pareek G, Miner M, Sfikakis PP, Protogerou A, Misra DP, Agarwal V, Sharma AM, Viswanathan V, Rathore VS, Turk M, Kolluri R, Viskovic K, Cuadrado-Godia E, Kitas GD, Nicolaides A, Suri JS. 3-D optimized classification and characterization artificial intelligence paradigm for cardiovascular/stroke risk stratification using carotid ultrasound-based delineated plaque: Atheromatic™ 2.0. Comput Biol Med 2020; 125:103958. [PMID: 32927257 DOI: 10.1016/j.compbiomed.2020.103958] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 08/02/2020] [Accepted: 08/03/2020] [Indexed: 12/18/2022]
Abstract
BACKGROUND AND PURPOSE Atherosclerotic plaque tissue rupture is one of the leading causes of strokes. Early carotid plaque monitoring can help reduce cardiovascular morbidity and mortality. Manual ultrasound plaque classification and characterization methods are time-consuming and can be imprecise due to significant variations in tissue characteristics. We report a novel artificial intelligence (AI)-based plaque tissue classification and characterization system. METHODS We hypothesize that symptomatic plaque is hypoechoic due to its large lipid core and minimal collagen, as well as its heterogeneous makeup. Meanwhile, asymptomatic plaque is hyperechoic due to its small lipid core, abundant collagen, and the fact that it is often calcified. We designed a computer-aided diagnosis (CADx) system consisting of three kinds of deep learning (DL) classification paradigms: Deep Convolutional Neural Network (DCNN), Visual Geometric Group-16 (VGG16), and transfer learning, (tCNN). DCNN was 3-D optimized by varying the number of CNN layers and data augmentation frameworks. The DL systems were benchmarked against four types of machine learning (ML) classification systems, and the CADx system was characterized using two novel strategies consisting of DL mean feature strength (MFS) and a bispectrum model using higher-order spectra. RESULTS After balancing symptomatic and asymptomatic plaque classes, a five-fold augmentation process was applied, yielding 1000 carotid scans in each class. Then, using a K10 protocol (trained to test the ratio of 90%-10%), tCNN and DCNN yielded accuracy (area under the curve (AUC)) pairs of 83.33%, 0.833 (p < 0.0001) and 95.66%, 0.956 (p < 0.0001), respectively. DCNN was superior to ML by 7.01%. As part of the characterization process, the MFS of the symptomatic plaque was found to be higher compared to the asymptomatic plaque by 17.5% (p < 0.0001). A similar pattern was seen in the bispectrum, which was higher for symptomatic plaque by 5.4% (p < 0.0001). It took <2 s to perform the online CADx process on a supercomputer. CONCLUSIONS The performance order of the three AI systems was DCNN > tCNN > ML. Bispectrum-based on higher-order spectra proved a powerful paradigm for plaque tissue characterization. Overall, the AI-based systems offer a powerful solution for plaque tissue classification and characterization.
Collapse
Affiliation(s)
- Sanagala S Skandha
- CSE Department, CMR College of Engineering & Technology, Hyderabad, India; CSE Department, Bennett University, Greater Noida, UP, India
| | - Suneet K Gupta
- CSE Department, Bennett University, Greater Noida, UP, India
| | - Luca Saba
- Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), Cagliari, Italy
| | - Vijaya K Koppula
- CSE Department, CMR College of Engineering & Technology, Hyderabad, India
| | - Amer M Johri
- Department of Medicine, Division of Cardiology, Queen's University, Kingston, Ontario, Canada
| | - Narendra N Khanna
- Department of Cardiology, Indraprastha APOLLO Hospitals, New Delhi, India
| | - Sophie Mavrogeni
- Cardiology Clinic, Onassis Cardiac Surgery Center, Athens, Greece
| | - John R Laird
- Heart and Vascular Institute, Adventist Health St. Helena, St Helena, CA, USA
| | - Gyan Pareek
- Minimally Invasive Urology Institute, Brown University, Providence, RI, USA
| | - Martin Miner
- Men's Health Center, Miriam Hospital Providence, RI, USA
| | - Petros P Sfikakis
- Rheumatology Unit, National Kapodistrian University of Athens, Greece
| | - Athanasios Protogerou
- Department of Cardiovascular Prevention, National and Kapodistrian Univ. of Athens, Greece
| | - Durga P Misra
- Dept. of Clinical Immunology and Rheumatology, SGPGIMS, Lucknow, India
| | - Vikas Agarwal
- Dept. of Clinical Immunology and Rheumatology, SGPGIMS, Lucknow, India
| | - Aditya M Sharma
- Division of Cardiovascular Medicine, University of Virginia, VA, USA
| | - Vijay Viswanathan
- MV Hospital for Diabetes & Professor M Viswanathan Diabetes Research Centre, Chennai, India
| | - Vijay S Rathore
- Nephrology Department, Kaiser Permanente, Sacramento, CA, USA
| | - Monika Turk
- The Hanse-Wissenschaftskolleg Institute for Advanced Study, Delmenhorst, Germany
| | | | | | | | - George D Kitas
- R & D Academic Affairs, Dudley Group NHS Foundation Trust, Dudley, UK
| | - Andrew Nicolaides
- Vascular Screening and Diagnostic Centre, University of Nicosia, Nicosia, Cyprus
| | - Jasjit S Suri
- Stroke Monitoring and Diagnostic Division, AtheroPoint™, Roseville, CA, USA.
| |
Collapse
|
8
|
Shi Z, Li J, Zhao M, Peng W, Meddings Z, Jiang T, Liu Q, Teng Z, Lu J. Quantitative Histogram Analysis on Intracranial Atherosclerotic Plaques: A High-Resolution Magnetic Resonance Imaging Study. Stroke 2020; 51:2161-2169. [PMID: 32568660 PMCID: PMC7306260 DOI: 10.1161/strokeaha.120.029062] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND AND PURPOSE Intracranial atherosclerosis is one of the main causes of stroke, and high-resolution magnetic resonance imaging provides useful imaging biomarkers related to the risk of ischemic events. This study aims to evaluate differences in histogram features between culprit and nonculprit intracranial atherosclerosis using high-resolution magnetic resonance imaging. METHODS Two hundred forty-seven patients with intracranial atherosclerosis who underwent high-resolution magnetic resonance imaging sequentially between January 2015 and December 2016 were recruited. Quantitative features, including stenosis, plaque burden, minimum luminal area, intraplaque hemorrhage, enhancement ratio, and dispersion of signal intensity (coefficient of variation), were analyzed based on T2-, T1-, and contrast-enhanced T1-weighted images. Step-wise regression analysis was used to identify key determinates differentiating culprit and nonculprit plaques and to calculate the odds ratios (ORs) with 95% CIs. RESULTS In total, 190 plaques were identified, of which 88 plaques (37 culprit and 51 nonculprit) were located in the middle cerebral artery and 102 (57 culprit and 45 nonculprit) in the basilar artery. Nearly 90% of culprit lesions had a degree of luminal stenosis of <70%. Multiple logistic regression analyses showed that intraplaque hemorrhage (OR, 16.294 [95% CI, 1.043-254.632]; P=0.047), minimum luminal area (OR, 1.468 [95% CI, 1.032-2.087]; P=0.033), and coefficient of variation (OR, 13.425 [95% CI, 3.987-45.204]; P<0.001) were 3 significant features in defining culprit plaques in middle cerebral artery. The enhancement ratio (OR, 9.476 [95% CI, 1.256-71.464]; P=0.029), intraplaque hemorrhage (OR, 2.847 [95% CI, 0.971-10.203]; P=0.046), and coefficient of variation (OR, 10.068 [95% CI, 2.820-21.343]; P<0.001) were significantly associated with plaque type in basilar artery. Coefficient of variation was a strong independent predictor in defining plaque type for both middle cerebral artery and basilar artery with sensitivity, specificity, and accuracy being 0.79, 0.80, and 0.80, respectively. CONCLUSIONS Features characterized by high-resolution magnetic resonance imaging provided complementary values over luminal stenosis in defined lesion type for intracranial atherosclerosis; the dispersion of signal intensity in histogram analysis was a particularly effective predictive parameter.
Collapse
Affiliation(s)
- Zhang Shi
- Department of Radiology (Z.S., J. Li, W.P., T.J., Q.L., J. Lu), Changhai Hospital, Naval Medical University, Shanghai, China
- Department of Radiology, University of Cambridge, United Kingdom (Z.S., Z.M., Z.T.)
| | - Jing Li
- Department of Radiology (Z.S., J. Li, W.P., T.J., Q.L., J. Lu), Changhai Hospital, Naval Medical University, Shanghai, China
| | - Ming Zhao
- Department of Neurology (M.Z.), Changhai Hospital, Naval Medical University, Shanghai, China
| | - Wenjia Peng
- Department of Radiology (Z.S., J. Li, W.P., T.J., Q.L., J. Lu), Changhai Hospital, Naval Medical University, Shanghai, China
| | - Zakaria Meddings
- Department of Radiology, University of Cambridge, United Kingdom (Z.S., Z.M., Z.T.)
| | - Tao Jiang
- Department of Radiology (Z.S., J. Li, W.P., T.J., Q.L., J. Lu), Changhai Hospital, Naval Medical University, Shanghai, China
| | - Qi Liu
- Department of Radiology (Z.S., J. Li, W.P., T.J., Q.L., J. Lu), Changhai Hospital, Naval Medical University, Shanghai, China
| | - Zhongzhao Teng
- Department of Radiology, University of Cambridge, United Kingdom (Z.S., Z.M., Z.T.)
- Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, China (Z.T.)
| | - Jianping Lu
- Department of Radiology (Z.S., J. Li, W.P., T.J., Q.L., J. Lu), Changhai Hospital, Naval Medical University, Shanghai, China
| |
Collapse
|
9
|
Liu X, Zhou P, Qiu T, Wu DO. Blockchain-Enabled Contextual Online Learning under Local Differential Privacy for Coronary Heart Disease Diagnosis in Mobile Edge Computing. IEEE J Biomed Health Inform 2020; PP:2177-2188. [PMID: 32750921 DOI: 10.1109/jbhi.2020.2999497] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
Due to the increasing medical data for coronary heart disease (CHD) diagnosis, how to assist doctors to make proper clinical diagnosis has attracted considerable attention. However, it faces many challenges, including personalized diagnosis, high dimensional datasets, clinical privacy concerns and insufficient computing resources. To handle these issues, we propose a novel blockchain-enabled contextual online learning model under local differential privacy for CHD diagnosis in mobile edge computing. Various edge nodes in the network can collaborate with each other to achieve information sharing, which guarantees that CHD diagnosis is suitable and reliable. To support the dynamically increasing dataset, we adopt a top-down tree structure to contain medical records which is partitioned adaptively. Furthermore, we consider patients' contexts (e.g., lifestyle, medical history records, and physical features) to provide more accurate diagnosis. Besides, to protect the privacy of patients and medical transactions without any trusted third party, we utilize the local differential privacy with randomised response mechanism and ensure blockchain-enabled information-sharing authentication under multi-party computation. Based on the theoretical analysis, we confirm that we provide real-time and precious CHD diagnosis for patients with sublinear regret, and achieve efficient privacy protection. The experimental results validate that our algorithm {outperforms} other algorithm benchmarks on running time, error rate and diagnosis accuracy.
Collapse
|
10
|
Latha S, Samiappan D, Kumar R. Carotid artery ultrasound image analysis: A review of the literature. Proc Inst Mech Eng H 2020; 234:417-443. [PMID: 31960771 DOI: 10.1177/0954411919900720] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Stroke is one of the prominent causes of death in the recent days. The existence of susceptible plaque in the carotid artery can be used in ascertaining the possibilities of cardiovascular diseases and long-term disabilities. The imaging modality used for early screening of the disease is B-mode ultrasound image of the person in the artery area. The objective of this article is to give a widespread review of the imaging modes and methods used for studying the carotid artery for identifying stroke, atherosclerosis and related cardiovascular diseases. We encompass the review in methods used for artery wall tracking, intima-media, and lumen segmentation which will help in finding the extent of the disease. Due to the characteristics of the imaging modality used, the images have speckle noise which worsens the image quality. Adaptive homomorphic filtering with wavelet and contourlet transforms, Levy Shrink, gamma distribution were used for image denoising. Learning-based neural network approaches for denoising give better edge preservation. Domain knowledge-based segmentation approaches have proved to provide more accurate intima-media thickness measurements. There is a requirement of useful fully automatic segmentation approaches, 3D, 4D systems, and plaque motion analysis. Taking into consideration the image priors like geometry, imaging physics, intensity and temporal data, image analysis has to be performed. Encouragingly more research has focused on content-specific segmentation and classification techniques. With the evaluation of machine learning algorithms, classifying the image as with or without a fat deposit has gained better accuracy and sensitivity. Machine learning-based approaches like self-organizing map, k-nearest neighborhood and support vector machine achieve promising accuracy and sensitivity in classification. The literature reveals that there is more scope in identifying a patient-specific model in a fully automatic manner.
Collapse
Affiliation(s)
- S Latha
- Department of Electronics and Communication Engineering, SRM Institute of Science and Technology, Chennai, India
| | - Dhanalakshmi Samiappan
- Department of Electronics and Communication Engineering, SRM Institute of Science and Technology, Chennai, India
| | - R Kumar
- Department of Electronics and Communication Engineering, SRM Institute of Science and Technology, Chennai, India
| |
Collapse
|
11
|
Narisetti N, Neumann K, Röder MS, Gladilin E. Automated Spike Detection in Diverse European Wheat Plants Using Textural Features and the Frangi Filter in 2D Greenhouse Images. FRONTIERS IN PLANT SCIENCE 2020; 11:666. [PMID: 32655586 PMCID: PMC7324796 DOI: 10.3389/fpls.2020.00666] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Accepted: 04/29/2020] [Indexed: 05/22/2023]
Abstract
Spike is one of the crop yield organs in wheat plants. Determination of the phenological stages, including heading time point (HTP), and area of spike from non-invasive phenotyping images provides the necessary information for the inference of growth-related traits. The algorithm previously developed by Qiongyan et al. for spike detection in 2-D images turns out to be less accurate when applied to the European cultivars that produce many more leaves. Therefore, we here present an improved and extended method where (i) wavelet amplitude is used as an input to the Laws texture energy-based neural network instead of original grayscale images and (ii) non-spike structures (e.g., leaves) are subsequently suppressed by combining the result of the neural network prediction with a Frangi-filtered image. Using this two-step approach, a 98.6% overall accuracy of neural network segmentation based on direct comparison with ground-truth data could be achieved. Moreover, the comparative error rate in spike HTP detection and growth correlation among the ground truth, the algorithm developed by Qiongyan et al., and the proposed algorithm are discussed in this paper. The proposed algorithm was also capable of significantly reducing the error rate of the HTP detection by 75% and improving the accuracy of spike area estimation by 50% in comparison with the Qionagyan et al. method. With these algorithmic improvements, HTP detection on a diverse set of 369 plants was performed in a high-throughput manner. This analysis demonstrated that the HTP of 104 plants (comprises of 57 genotypes) with lower biomass and tillering range (e.g., earlier-heading types) were correctly determined. However, fine-tuning or extension of the developed method is required for high biomass plants where spike emerges within green bushes. In conclusion, our proposed method allows significantly more reliable results for HTP detection and spike growth analysis to be achieved in application to European cultivars with earlier-heading types.
Collapse
Affiliation(s)
- Narendra Narisetti
- Molecular Genetics, Leibniz Institute of Plant Genetics and Crop Plant Research (IPK), Gatersleben, Germany
| | - Kerstin Neumann
- Department of Genebank, Leibniz Institute of Plant Genetics and Crop Plant Research (IPK), Gatersleben, Germany
| | - Marion S. Röder
- Department of Genebank, Leibniz Institute of Plant Genetics and Crop Plant Research (IPK), Gatersleben, Germany
| | - Evgeny Gladilin
- Molecular Genetics, Leibniz Institute of Plant Genetics and Crop Plant Research (IPK), Gatersleben, Germany
- *Correspondence: Evgeny Gladilin
| |
Collapse
|
12
|
Savaş S, Topaloğlu N, Kazcı Ö, Koşar PN. Classification of Carotid Artery Intima Media Thickness Ultrasound Images with Deep Learning. J Med Syst 2019; 43:273. [PMID: 31278481 DOI: 10.1007/s10916-019-1406-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 06/25/2019] [Indexed: 02/01/2023]
Abstract
Cerebrovascular accident due to carotid artery disease is the most common cause of death in developed countries following heart disease and cancer. For a reliable early detection of atherosclerosis, Intima Media Thickness (IMT) measurement and classification are important. A new method for decision support purpose for the classification of IMT was proposed in this study. Ultrasound images are used for IMT measurements. Images are classified and evaluated by experts. This is a manual procedure, so it causes subjectivity and variability in the IMT classification. Instead, this article proposes a methodology based on artificial intelligence methods for IMT classification. For this purpose, a deep learning strategy with multiple hidden layers has been developed. In order to create the proposed model, convolutional neural network algorithm, which is frequently used in image classification problems, is used. 501 ultrasound images from 153 patients were used to test the model. The images are classified by two specialists, then the model is trained and tested on the images, and the results are explained. The deep learning model in the study achieved an accuracy of 89.1% in the IMT classification with 89% sensitivity and 88% specificity. Thus, the assessments in this paper have shown that this methodology performs reasonable results for IMT classification.
Collapse
Affiliation(s)
- Serkan Savaş
- Faculty of Technology, Computer Engineering Department Ph.D, Gazi University, Ankara, Turkey.
| | - Nurettin Topaloğlu
- Faculty of Technology, Computer Engineering Department, Gazi University, Ankara, Turkey
| | - Ömer Kazcı
- Department of Radiology, Ankara Training and Research Hospital, Ankara, Turkey
| | - Pınar Nercis Koşar
- Department of Radiology, Ankara Training and Research Hospital, Ankara, Turkey
| |
Collapse
|
13
|
Banchhor SK, Londhe ND, Araki T, Saba L, Radeva P, Khanna NN, Suri JS. Calcium detection, its quantification, and grayscale morphology-based risk stratification using machine learning in multimodality big data coronary and carotid scans: A review. Comput Biol Med 2018; 101:184-198. [DOI: 10.1016/j.compbiomed.2018.08.017] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 08/14/2018] [Accepted: 08/14/2018] [Indexed: 01/04/2023]
|
14
|
Molinari F, Raghavendra U, Gudigar A, Meiburger KM, Rajendra Acharya U. An efficient data mining framework for the characterization of symptomatic and asymptomatic carotid plaque using bidimensional empirical mode decomposition technique. Med Biol Eng Comput 2018; 56:1579-1593. [DOI: 10.1007/s11517-018-1792-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Accepted: 01/13/2018] [Indexed: 10/18/2022]
|
15
|
Banchhor SK, Londhe ND, Araki T, Saba L, Radeva P, Laird JR, Suri JS. Wall-based measurement features provides an improved IVUS coronary artery risk assessment when fused with plaque texture-based features during machine learning paradigm. Comput Biol Med 2017; 91:198-212. [PMID: 29100114 DOI: 10.1016/j.compbiomed.2017.10.019] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2017] [Revised: 10/19/2017] [Accepted: 10/19/2017] [Indexed: 12/31/2022]
Abstract
BACKGROUND Planning of percutaneous interventional procedures involves a pre-screening and risk stratification of the coronary artery disease. Current screening tools use stand-alone plaque texture-based features and therefore lack the ability to stratify the risk. METHOD This IRB approved study presents a novel strategy for coronary artery disease risk stratification using an amalgamation of IVUS plaque texture-based and wall-based measurement features. Due to common genetic plaque makeup, carotid plaque burden was chosen as a gold standard for risk labels during training-phase of machine learning (ML) paradigm. Cross-validation protocol was adopted to compute the accuracy of the ML framework. A set of 59 plaque texture-based features was padded with six wall-based measurement features to show the improvement in stratification accuracy. The ML system was executed using principle component analysis-based framework for dimensionality reduction and uses support vector machine classifier for training and testing-phases. RESULTS The ML system produced a stratification accuracy of 91.28%, demonstrating an improvement of 5.69% when wall-based measurement features were combined with plaque texture-based features. The fused system showed an improvement in mean sensitivity, specificity, positive predictive value, and area under the curve by: 6.39%, 4.59%, 3.31% and 5.48%, respectively when compared to the stand-alone system. While meeting the stability criteria of 5%, the ML system also showed a high average feature retaining power and mean reliability of 89.32% and 98.24%, respectively. CONCLUSIONS The ML system showed an improvement in risk stratification accuracy when the wall-based measurement features were fused with the plaque texture-based features.
Collapse
Affiliation(s)
| | | | - Tadashi Araki
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
| | - Luca Saba
- Department of Radiology, University of Cagliari, Italy
| | - Petia Radeva
- Department of Mathematics and Computer Science, University of Barcelona, Barcelona, Spain
| | | | - Jasjit S Suri
- Monitoring and Diagnostic Division, AtheroPoint™, Roseville, CA, USA.
| |
Collapse
|
16
|
Karthik R, Menaka R. Computer-aided detection and characterization of stroke lesion – a short review on the current state-of-the art methods. IMAGING SCIENCE JOURNAL 2017. [DOI: 10.1080/13682199.2017.1370879] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- R. Karthik
- School of Electronics Engineering, VIT University, Chennai, India
| | - R. Menaka
- School of Electronics Engineering, VIT University, Chennai, India
| |
Collapse
|
17
|
Qiongyan L, Cai J, Berger B, Okamoto M, Miklavcic SJ. Detecting spikes of wheat plants using neural networks with Laws texture energy. PLANT METHODS 2017; 13:83. [PMID: 29046709 PMCID: PMC5640952 DOI: 10.1186/s13007-017-0231-1] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Accepted: 10/02/2017] [Indexed: 05/05/2023]
Abstract
BACKGROUND The spike of a cereal plant is the grain-bearing organ whose physical characteristics are proxy measures of grain yield. The ability to detect and characterise spikes from 2D images of cereal plants, such as wheat, therefore provides vital information on tiller number and yield potential. RESULTS We have developed a novel spike detection method for wheat plants involving, firstly, an improved colour index method for plant segmentation and, secondly, a neural network-based method using Laws texture energy for spike detection. The spike detection step was further improved by removing noise using an area and height threshold. The evaluation results showed an accuracy of over 80% in identification of spikes. In the proposed method we also measure the area of individual spikes as well as all spikes of individual plants under different experimental conditions. The correlation between the final average grain yield and spike area is also discussed in this paper. CONCLUSIONS Our highly accurate yield trait phenotyping method for spike number counting and spike area estimation, is useful and reliable not only for grain yield estimation but also for detecting and quantifying subtle phenotypic variations arising from genetic or environmental differences.
Collapse
Affiliation(s)
- Li Qiongyan
- School of Engineering, Beijing Forestry University, Beijing, 100083 China
| | - Jinhai Cai
- Phenomics and Bioinformatics Research Centre, University of South Australia, Mawson Lakes, SA 5095 Australia
| | - Bettina Berger
- The Plant Accelerator, Australian Plant Phenomics Facility, University of Adelaide, Waite Campus, Urrbrae, SA 5064 Australia
| | - Mamoru Okamoto
- School of Agriculture, Food and Wine, University of Adelaide, Urrbrae, SA 5064 Australia
| | - Stanley J. Miklavcic
- Phenomics and Bioinformatics Research Centre, University of South Australia, Mawson Lakes, SA 5095 Australia
| |
Collapse
|
18
|
Huang X, Zhang Y, Qian M, Meng L, Xiao Y, Niu L, Zheng R, Zheng H. Classification of Carotid Plaque Echogenicity by Combining Texture Features and Morphologic Characteristics. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:2253-2261. [PMID: 27582533 DOI: 10.7863/ultra.15.09002] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Accepted: 01/05/2016] [Indexed: 06/06/2023]
Abstract
OBJECTIVES Anechoic carotid plaques on sonography have been used to predict future cardiovascular or cerebrovascular events. The purpose of this study was to investigate whether carotid plaque echogenicity could be assessed objectively by combining texture features extracted by MaZda software (Institute of Electronics, Technical University of Lodz, Lodz, Poland) and morphologic characteristics, which may provide a promising method for early prediction of acute cardiovascular disease. METHODS A total of 268 plaque images were collected from 136 volunteers and classified into 85 hyperechoic, 83 intermediate, and 100 anechoic plaques. About 300 texture features were extracted from histogram, absolute gradient, run-length matrix, gray-level co-occurrence matrix, autoregressive model, and wavelet transform algorithms by MaZda. The morphologic characteristics, including degree of stenosis, maximum plaque intima-media thickness, and maximum plaque length, were measured by B-mode sonography. Statistically significant features were selected by analysis of covariance. The most discriminative features were obtained from statistically significant features by linear discriminant analysis. The K-nearest neighbor classifier was used to classify plaque echogenicity based on statistically significant and most discriminative features. RESULTS A total of 30 statistically significant features were selected among the plaques, and 2 most discriminative features were obtained from the statistically significant features. The classification accuracy rates for 3 types of plaques based on statistically significant and most discriminative features were 72.03% (κ= 0.571; P < .001) and 88.14% (κ= 0.820; P < .001), respectively. The receiver operating characteristic curve for identifying anechoic plaques showed an area under the curve of 0.918 when the most discriminative features were used to train the classifier. CONCLUSIONS It is feasible to classify carotid plaque echogenicity by combining texture features extracted from sonograms by MaZda and morphologic characteristics.
Collapse
Affiliation(s)
- Xiaowei Huang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yanling Zhang
- Department of Ultrasound, Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Ming Qian
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Long Meng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yang Xiao
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Lili Niu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Rongqin Zheng
- Department of Ultrasound, Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
19
|
Abstract
Causes of brain injury during endovascular carotid intervention are protean. Mechanisms of injury include embolic and hemodynamic events, acute carotid occlusions occurring through a variety of means, and the relatively rare contrast-induced encephalopathy. Embolic injury may result from micro- and macroembolization and most commonly causes ischemic stroke when sufficiently severe. Hemodynamic injury may proceed from hemodynamic depression and hypoperfusion (which may result in watershed infarction) or the hyperperfusion syndrome, which may, if severe, result in hemorrhagic stroke. Embolic and dynamic causes of stroke may either occur intraprocedurally or at a variable time after stent placement and may be co-related. Impaired clearance of emboli due to relative hypoperfusion may exacerbate their clinical relevance. Other causes of stroke include acute carotid occlusions, which most commonly occur procedurally due to flow-limiting spasm, acute dissection, and, if a filter-type cerebral protection device has been used, filter occlusion due to a large trapped embolic load. These scenarios may result in stroke if not recognized and dealt with appropriately. Acute stent thrombosis may occur within 24 hours of the procedure as a result of adverse hemodynamic factors or suboptimal patient response to procedural heparin and antiplatelet agents, or it may occur after the procedure, again perhaps as a result of suboptimal response to antiaggregate drugs.
Collapse
|
20
|
A Computer-Aided Diagnosis System for Measuring Carotid Artery Intima-Media Thickness (IMT) Using Quaternion Vectors. J Med Syst 2016; 40:149. [PMID: 27137786 DOI: 10.1007/s10916-016-0507-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Accepted: 04/19/2016] [Indexed: 10/21/2022]
Abstract
This study aims investigating adjustable distant fuzzy c-means segmentation on carotid Doppler images, as well as quaternion-based convolution filters and saliency mapping procedures. We developed imaging software that will simplify the measurement of carotid artery intima-media thickness (IMT) on saliency mapping images. Additionally, specialists evaluated the present images and compared them with saliency mapping images. In the present research, we conducted imaging studies of 25 carotid Doppler images obtained by the Department of Cardiology at Fırat University. After implementing fuzzy c-means segmentation and quaternion-based convolution on all Doppler images, we obtained a model that can be analyzed easily by the doctors using a bottom-up saliency model. These methods were applied to 25 carotid Doppler images and then interpreted by specialists. In the present study, we used color-filtering methods to obtain carotid color images. Saliency mapping was performed on the obtained images, and the carotid artery IMT was detected and interpreted on the obtained images from both methods and the raw images are shown in Results. Also these results were investigated by using Mean Square Error (MSE) for the raw IMT images and the method which gives the best performance is the Quaternion Based Saliency Mapping (QBSM). 0,0014 and 0,000191 mm(2) MSEs were obtained for artery lumen diameters and plaque diameters in carotid arteries respectively. We found that computer-based image processing methods used on carotid Doppler could aid doctors' in their decision-making process. We developed software that could ease the process of measuring carotid IMT for cardiologists and help them to evaluate their findings.
Collapse
|
21
|
Araki T, Ikeda N, Shukla D, Jain PK, Londhe ND, Shrivastava VK, Banchhor SK, Saba L, Nicolaides A, Shafique S, Laird JR, Suri JS. PCA-based polling strategy in machine learning framework for coronary artery disease risk assessment in intravascular ultrasound: A link between carotid and coronary grayscale plaque morphology. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2016; 128:137-158. [PMID: 27040838 DOI: 10.1016/j.cmpb.2016.02.004] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Accepted: 02/16/2016] [Indexed: 06/05/2023]
Abstract
BACKGROUND AND OBJECTIVE Percutaneous coronary interventional procedures need advance planning prior to stenting or an endarterectomy. Cardiologists use intravascular ultrasound (IVUS) for screening, risk assessment and stratification of coronary artery disease (CAD). We hypothesize that plaque components are vulnerable to rupture due to plaque progression. Currently, there are no standard grayscale IVUS tools for risk assessment of plaque rupture. This paper presents a novel strategy for risk stratification based on plaque morphology embedded with principal component analysis (PCA) for plaque feature dimensionality reduction and dominant feature selection technique. The risk assessment utilizes 56 grayscale coronary features in a machine learning framework while linking information from carotid and coronary plaque burdens due to their common genetic makeup. METHOD This system consists of a machine learning paradigm which uses a support vector machine (SVM) combined with PCA for optimal and dominant coronary artery morphological feature extraction. Carotid artery proven intima-media thickness (cIMT) biomarker is adapted as a gold standard during the training phase of the machine learning system. For the performance evaluation, K-fold cross validation protocol is adapted with 20 trials per fold. For choosing the dominant features out of the 56 grayscale features, a polling strategy of PCA is adapted where the original value of the features is unaltered. Different protocols are designed for establishing the stability and reliability criteria of the coronary risk assessment system (cRAS). RESULTS Using the PCA-based machine learning paradigm and cross-validation protocol, a classification accuracy of 98.43% (AUC 0.98) with K=10 folds using an SVM radial basis function (RBF) kernel was achieved. A reliability index of 97.32% and machine learning stability criteria of 5% were met for the cRAS. CONCLUSIONS This is the first Computer aided design (CADx) system of its kind that is able to demonstrate the ability of coronary risk assessment and stratification while demonstrating a successful design of the machine learning system based on our assumptions.
Collapse
Affiliation(s)
- Tadashi Araki
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
| | - Nobutaka Ikeda
- Cardiovascular Medicine, National Center for Global Health and Medicine, Tokyo, Japan
| | - Devarshi Shukla
- Department of Electrical Engineering, NIT Raipur, Chhattisgarh, India
| | - Pankaj K Jain
- Department of Electrical Engineering, NIT Raipur, Chhattisgarh, India
| | - Narendra D Londhe
- Department of Electrical Engineering, NIT Raipur, Chhattisgarh, India
| | | | - Sumit K Banchhor
- Department of Electrical Engineering, NIT Raipur, Chhattisgarh, India
| | - Luca Saba
- Department of Radiology, University of Cagliari, Italy
| | - Andrew Nicolaides
- Vascular Screening and Diagnostic Centre, London, England, United Kingdom; Vascular Diagnostic Center, University of Cyprus, Nicosia, Cyprus
| | - Shoaib Shafique
- CorVasc Vascular Laboratory, 8433 Harcourt Rd #100, Indianapolis, IN, USA
| | - John R Laird
- UC Davis Vascular Center, University of California, Davis, CA, USA
| | - Jasjit S Suri
- Monitoring and Diagnostic Division, AtheroPoint™, Roseville, CA, USA; Point-Of-Care Devices, Global Biomedical Technologies, Inc., Roseville, CA, USA; Department of Electrical Engineering, University of Idaho (Affl.), Pocatello, ID, USA.
| |
Collapse
|
22
|
A Review on Carotid Ultrasound Atherosclerotic Tissue Characterization and Stroke Risk Stratification in Machine Learning Framework. Curr Atheroscler Rep 2016; 17:55. [PMID: 26233633 DOI: 10.1007/s11883-015-0529-2] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Cardiovascular diseases (including stroke and heart attack) are identified as the leading cause of death in today's world. However, very little is understood about the arterial mechanics of plaque buildup, arterial fibrous cap rupture, and the role of abnormalities of the vasa vasorum. Recently, ultrasonic echogenicity characteristics and morphological characterization of carotid plaque types have been shown to have clinical utility in classification of stroke risks. Furthermore, this characterization supports aggressive and intensive medical therapy as well as procedures, including endarterectomy and stenting. This is the first state-of-the-art review to provide a comprehensive understanding of the field of ultrasonic vascular morphology tissue characterization. This paper presents fundamental and advanced ultrasonic tissue characterization and feature extraction methods for analyzing plaque. Additionally, the paper shows how the risk stratification is achieved using machine learning paradigms. More advanced methods need to be developed which can segment the carotid artery walls into multiple regions such as the bulb region and areas both proximal and distal to the bulb. Furthermore, multimodality imaging is needed for validation of such advanced methods for stroke and cardiovascular risk stratification.
Collapse
|
23
|
Araki T, Ikeda N, Shukla D, Londhe ND, Shrivastava VK, Banchhor SK, Saba L, Nicolaides A, Shafique S, Laird JR, Suri JS. A new method for IVUS-based coronary artery disease risk stratification: A link between coronary & carotid ultrasound plaque burdens. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2016; 124:161-179. [PMID: 26707374 DOI: 10.1016/j.cmpb.2015.10.022] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Revised: 10/12/2015] [Accepted: 10/21/2015] [Indexed: 06/05/2023]
Abstract
Interventional cardiologists have a deep interest in risk stratification prior to stenting and percutaneous coronary intervention (PCI) procedures. Intravascular ultrasound (IVUS) is most commonly adapted for screening, but current tools lack the ability for risk stratification based on grayscale plaque morphology. Our hypothesis is based on the genetic makeup of the atherosclerosis disease, that there is evidence of a link between coronary atherosclerosis disease and carotid plaque built up. This novel idea is explored in this study for coronary risk assessment and its classification of patients between high risk and low risk. This paper presents a strategy for coronary risk assessment by combining the IVUS grayscale plaque morphology and carotid B-mode ultrasound carotid intima-media thickness (cIMT) - a marker of subclinical atherosclerosis. Support vector machine (SVM) learning paradigm is adapted for risk stratification, where both the learning and testing phases use tissue characteristics derived from six feature combinational spaces, which are then used by the SVM classifier with five different kernels sets. These six feature combinational spaces are designed using 56 novel feature sets. K-fold cross validation protocol with 10 trials per fold is used for optimization of best SVM-kernel and best feature combination set. IRB approved coronary IVUS and carotid B-mode ultrasound were jointly collected on 15 patients (2 days apart) via: (a) 40MHz catheter utilizing iMap (Boston Scientific, Marlborough, MA, USA) with 2865 frames per patient (42,975 frames) and (b) linear probe B-mode carotid ultrasound (Toshiba scanner, Japan). Using the above protocol, the system shows the classification accuracy of 94.95% and AUC of 0.95 using optimized feature combination. This is the first system of its kind for risk stratification as a screening tool to prevent excessive cost burden and better patients' cardiovascular disease management, while validating our two hypotheses.
Collapse
Affiliation(s)
- Tadashi Araki
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, Tokyo, Japan
| | - Nobutaka Ikeda
- Cardiovascular Medicine, National Center for Global Health and Medicine, Tokyo, Japan
| | - Devarshi Shukla
- Department of Electrical Engineering, NIT Raipur, Chhattisgarh, India; Department of Electrical Engineering, University of Idaho (Affl.), ID, USA
| | - Narendra D Londhe
- Department of Electrical Engineering, NIT Raipur, Chhattisgarh, India; Department of Electrical Engineering, University of Idaho (Affl.), ID, USA
| | | | - Sumit K Banchhor
- Department of Electrical Engineering, NIT Raipur, Chhattisgarh, India; Department of Electrical Engineering, University of Idaho (Affl.), ID, USA
| | - Luca Saba
- Department of Radiology, University of Cagliari, Italy
| | - Andrew Nicolaides
- Vascular Screening and Diagnostic Centre, London, England, United Kingdom; Vascular Diagnostic Center, University of Cyprus, Nicosia, Cyprus
| | | | - John R Laird
- UC Davis Vascular Center, University of California, Davis, CA, USA
| | - Jasjit S Suri
- Monitoring and Diagnostic Division, AtheroPoint™, Roseville, CA, USA; Department of Electrical Engineering, University of Idaho (Affl.), ID, USA.
| |
Collapse
|
24
|
Kriti, Virmani J. Comparison of CAD Systems for Three Class Breast Tissue Density Classification Using Mammographic Images. MEDICAL IMAGING IN CLINICAL APPLICATIONS 2016. [DOI: 10.1007/978-3-319-33793-7_5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
25
|
Afonso D, Seabra J, Pedro LM, Fernandes JFE, Sanches JM. An Ultrasonographic Risk Score For Detecting Symptomatic Carotid Atherosclerotic Plaques. IEEE J Biomed Health Inform 2015; 19:1505-13. [DOI: 10.1109/jbhi.2014.2359236] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
26
|
Acharya UR, Sree SV, Molinari F, Saba L, Nicolaides A, Suri JS. An automated technique for carotid far wall classification using grayscale features and wall thickness variability. JOURNAL OF CLINICAL ULTRASOUND : JCU 2015; 43:302-311. [PMID: 24909942 DOI: 10.1002/jcu.22183] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2013] [Revised: 03/05/2014] [Accepted: 05/09/2014] [Indexed: 06/03/2023]
Abstract
PURPOSE To test a computer-aided diagnostic method for differentiating symptomatic from asymptomatic carotid B-mode ultrasonographic images. METHODS Our system (called Atheromatic) automatically computed the intima-media thickness (IMT) of the carotid far wall using AtheroEdge, calculated nonlinear features based on higher order spectra, and used these features and IMT and IMT variability (IMTVpoly ) to associate each image to a feature vector that was then labeled as symptomatic or asymptomatic (Sym/Asym) by a multiclassifiers system. We tested this method on a database of 118 carotid artery images from 37 symptomatic and 22 asymptomatic patients RESULTS The highest accuracy (99.1%) was obtained by the support vector machine classifier using seven features. These features, relevant to discriminate Sym/Asym, included IMT and IMTVpoly , along with the bispectral entropies of the distal wall image at 77°, 78°, and 79° angles. CONCLUSIONS Classification in Sym/Asym of the far carotid wall is feasible and accurate and could be useful for the early detection of atherosclerosis and to identify patients with higher cardiovascular risk.
Collapse
Affiliation(s)
- U Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore; Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | | | | | | | | | | |
Collapse
|
27
|
Pazinato DV, Stein BV, de Almeida WR, Werneck RDO, Mendes Júnior PR, Penatti OAB, Torres RDS, Menezes FH, Rocha A. Pixel-Level Tissue Classification for Ultrasound Images. IEEE J Biomed Health Inform 2014; 20:256-67. [PMID: 25561598 DOI: 10.1109/jbhi.2014.2386796] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Pixel-level tissue classification for ultrasound images, commonly applied to carotid images, is usually based on defining thresholds for the isolated pixel values. Ranges of pixel values are defined for the classification of each tissue. The classification of pixels is then used to determine the carotid plaque composition and, consequently, to determine the risk of diseases (e.g., strokes) and whether or not a surgery is necessary. The use of threshold-based methods dates from the early 2000s but it is still widely used for virtual histology. METHODOLOGY/PRINCIPAL FINDINGS We propose the use of descriptors that take into account information about a neighborhood of a pixel when classifying it. We evaluated experimentally different descriptors (statistical moments, texture-based, gradient-based, local binary patterns, etc.) on a dataset of five types of tissues: blood, lipids, muscle, fibrous, and calcium. The pipeline of the proposed classification method is based on image normalization, multiscale feature extraction, including the proposal of a new descriptor, and machine learning classification. We have also analyzed the correlation between the proposed pixel classification method in the ultrasound images and the real histology with the aid of medical specialists. CONCLUSIONS/SIGNIFICANCE The classification accuracy obtained by the proposed method with the novel descriptor in the ultrasound tissue images (around 73%) is significantly above the accuracy of the state-of-the-art threshold-based methods (around 54%). The results are validated by statistical tests. The correlation between the virtual and real histology confirms the quality of the proposed approach showing it is a robust ally for the virtual histology in ultrasound images.
Collapse
|
28
|
Gastounioti A, Makrodimitris S, Golemati S, Kadoglou NPE, Liapis CD, Nikita KS. A novel computerized tool to stratify risk in carotid atherosclerosis using kinematic features of the arterial wall. IEEE J Biomed Health Inform 2014; 19:1137-45. [PMID: 24951709 DOI: 10.1109/jbhi.2014.2329604] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Valid characterization of carotid atherosclerosis (CA) is a crucial public health issue, which would limit the major risks held by CA for both patient safety and state economies. This paper investigated the unexplored potential of kinematic features in assisting the diagnostic decision for CA in the framework of a computer-aided diagnosis (CAD) tool. To this end, 15 CAD schemes were designed and were fed with a wide variety of kinematic features of the atherosclerotic plaque and the arterial wall adjacent to the plaque for 56 patients from two different hospitals. The CAD schemes were benchmarked in terms of their ability to discriminate between symptomatic and asymptomatic patients and the combination of the Fisher discriminant ratio, as a feature-selection strategy, and support vector machines, in the classification module, was revealed as the optimal motion-based CAD tool. The particular CAD tool was evaluated with several cross-validation strategies and yielded higher than 88% classification accuracy; the texture-based CAD performance in the same dataset was 80%. The incorporation of kinematic features of the arterial wall in CAD seems to have a particularly favorable impact on the performance of image-data-driven diagnosis for CA, which remains to be further elucidated in future prospective studies on large datasets.
Collapse
|
29
|
Casa Almeida M, Serrano CS, Rejano JJ, Díaz JR, Lugo MB, Roldán JR. Reliability of texture analysis using co‐occurrence matrices (glcm) on photographic image in the assessment of cellulite in a Spanish population. J Eur Acad Dermatol Venereol 2014; 29:315-324. [DOI: 10.1111/jdv.12534] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2013] [Accepted: 03/28/2014] [Indexed: 11/28/2022]
Affiliation(s)
| | | | | | - J. Ríos Díaz
- ECOFISTEM Research Group Facultad de Ciencias de la Salud Universidad Católica San Antonio de Murcia (UCAM) Murcia Spain
| | | | | |
Collapse
|
30
|
Pedro LM, Sanches JM, Seabra J, Suri JS, Fernandes E Fernandes J. Asymptomatic carotid disease--a new tool for assessing neurological risk. Echocardiography 2013; 31:353-61. [PMID: 24117920 DOI: 10.1111/echo.12348] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Active carotid plaques are associated with atheroembolism and neurological events; its identification is crucial for stroke prevention. High-definition ultrasound (HDU) can be used to recognize plaque structure in carotid bifurcation stenosis associated with plaque vulnerability and occurrence of brain ischemic events. A new computer-assisted HDU method to study the echomorphology of the carotid plaque and to determine a risk score for developing appropriate symptoms is proposed in this study. Plaque echomorphology characteristics such as presence of ulceration at the plaque surface, juxta-luminal location of echolucent areas, echoheterogeneity were obtained from B-mode ultrasound scans using several image processing algorithms and were combined with measurement of severity of stenosis to obtain a clinical score--enhanced activity index (EAI)--which was correlated with the presence or absence of ipsilateral appropriate ischemic symptoms. An optimal cutoff value of EAI was determined to obtain the best separation between symptomatic (active) from asymptomatic (inactive) plaques and its diagnostic yield was compared to other 2 reference methods by means of receiver-operating characteristic (ROC) analysis. Classification performance was evaluated by leave-one-patient-out cross-validation applied to a cohort of 146 carotid plaques from 99 patients. The proposed method was benchmarked against (a) degree of stenosis criteria and (b) earlier proposed activity index (AI) and demonstrated that EAI yielded the highest accuracy up to an accuracy of 77% to predict asymptomatic plaques that developed symptoms in a prospective cross-sectional study. Enhanced activity index is a noninvasive, easy to obtain parameter, which provided accurate estimation of neurological risk of carotid plaques.
Collapse
Affiliation(s)
- Luís M Pedro
- Faculty of Medicine, Lisbon Academic Medical Centre, University of Lisbon and Lisbon Cardiovascular Institute, Lisbon, Portugal
| | | | | | | | | |
Collapse
|
31
|
Martinez-Sanchez P, Alexandrov AV. Ultrasonography of carotid plaque for the prevention of stroke. Expert Rev Cardiovasc Ther 2013; 11:1425-40. [PMID: 23980574 DOI: 10.1586/14779072.2013.816475] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
A carotid ultrasonography is a non-invasive technique that provides an accurate and reliable characterization of the broad spectrum of carotid arteriosclerosis, from the intima-media thickness to the atherosclerotic plaque. Carotid ultrasonography has become a useful tool for identifying patients at high risk of stroke and selecting those who can benefit most from revascularization therapies such as carotid endarterectomy and stenting. In addition to the degree of stenosis, plaque echomorphology has emerged in recent years as an important contributory factor to stroke risk. Changes in plaque echogenicity, as measured by the quantitative computer-assisted ultrasonography index, could be a marker of plaque instability as well as an indicator of plaque remodeling, thereby providing the means for monitoring anti-atherosclerosis drugs such as statins.
Collapse
Affiliation(s)
- Patricia Martinez-Sanchez
- Department of Neurology and Stroke Center, IdiPAZ Health Research Institute, La Paz University Hospital, Autonomous University of Madrid, Spain
| | | |
Collapse
|
32
|
Golemati S, Gastounioti A, Nikita KS. Toward Novel Noninvasive and Low-Cost Markers for Predicting Strokes in Asymptomatic Carotid Atherosclerosis: The Role of Ultrasound Image Analysis. IEEE Trans Biomed Eng 2013; 60:652-8. [DOI: 10.1109/tbme.2013.2244601] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
33
|
Acharya UR, Mookiah MRK, Vinitha Sree S, Afonso D, Sanches J, Shafique S, Nicolaides A, Pedro LM, Fernandes E Fernandes J, Suri JS. Atherosclerotic plaque tissue characterization in 2D ultrasound longitudinal carotid scans for automated classification: a paradigm for stroke risk assessment. Med Biol Eng Comput 2013; 51:513-23. [PMID: 23292291 DOI: 10.1007/s11517-012-1019-0] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2012] [Accepted: 12/17/2012] [Indexed: 11/25/2022]
Abstract
In the case of carotid atherosclerosis, to avoid unnecessary surgeries in asymptomatic patients, it is necessary to develop a technique to effectively differentiate symptomatic and asymptomatic plaques. In this paper, we have presented a data mining framework that characterizes the textural differences in these two classes using several grayscale features based on a novel combination of trace transform and fuzzy texture. The features extracted from the delineated plaque regions in B-mode ultrasound images were used to train several classifiers in order to prepare them for classification of new test plaques. Our CAD system was evaluated using two different databases consisting of 146 (44 symptomatic to 102 asymptomatic) and 346 (196 symptomatic and 150 asymptomatic) images. Both these databases differ in the way the ground truth was determined. We obtained classification accuracies of 93.1 and 85.3 %, respectively. The techniques are low cost, easily implementable, objective, and non-invasive. For more objective analysis, we have also developed novel integrated indices using a combination of significant features.
Collapse
Affiliation(s)
- U Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Clementi, Singapore.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Rao VSH, Kumar MN. Novel Approaches for Predicting Risk Factors of Atherosclerosis. IEEE J Biomed Health Inform 2013. [DOI: 10.1109/titb.2012.2227271] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
35
|
Hassan M, Chaudhry A, Khan A, Kim JY. Carotid artery image segmentation using modified spatial fuzzy c-means and ensemble clustering. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2012; 108:1261-1276. [PMID: 22981822 DOI: 10.1016/j.cmpb.2012.08.011] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2011] [Revised: 08/12/2012] [Accepted: 08/15/2012] [Indexed: 06/01/2023]
Abstract
Disease diagnosis based on ultrasound imaging is popular because of its non-invasive nature. However, ultrasound imaging system produces low quality images due to the presence of spackle noise and wave interferences. This shortcoming requires a considerable effort from experts to diagnose a disease from the carotid artery ultrasound images. Image segmentation is one of the techniques, which can help efficiently in diagnosing a disease from the carotid artery ultrasound images. Most of the pixels in an image are highly correlated. Considering the spatial information of surrounding pixels in the process of image segmentation may further improve the results. When data is highly correlated, one pixel may belong to more than one clusters with different degree of membership. In this paper, we present an image segmentation technique namely improved spatial fuzzy c-means and an ensemble clustering approach for carotid artery ultrasound images to identify the presence of plaque. Spatial, wavelets and gray level co-occurrence matrix (GLCM) features are extracted from carotid artery ultrasound images. Redundant and less important features are removed from the features set using genetic search process. Finally, segmentation process is performed on optimal or reduced features. Ensemble clustering with reduced feature set outperforms with respect to segmentation time as well as clustering accuracy. Intima-media thickness (IMT) is measured from the images segmented by the proposed approach. Based on IMT measured values, Multi-Layer Back-Propagation Neural Networks (MLBPNN) is used to classify the images into normal or abnormal. Experimental results show the learning capability of MLBPNN classifier and validate the effectiveness of our proposed technique. The proposed approach of segmentation and classification of carotid artery ultrasound images seems to be very useful for detection of plaque in carotid artery.
Collapse
Affiliation(s)
- Mehdi Hassan
- Department of Computer & Information Sciences, PIEAS, P.O. Nilore, Islamabad, Pakistan
| | | | | | | |
Collapse
|
36
|
LAMBROU ANTONIS, PAPADOPOULOS HARRIS, KYRIACOU EFTHYVOULOS, PATTICHIS CONSTANTINOSS, PATTICHIS MARIOSS, GAMMERMAN ALEXANDER, NICOLAIDES ANDREW. EVALUATION OF THE RISK OF STROKE WITH CONFIDENCE PREDICTIONS BASED ON ULTRASOUND CAROTID IMAGE ANALYSIS. INT J ARTIF INTELL T 2012. [DOI: 10.1142/s0218213012400167] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Conformal Predictors (CPs) are Machine Learning algorithms that can provide reliable confidence measures to their predictions. In this work, we make use of the Conformal Prediction framework for the assessment of stroke risk based on ultrasound images of atherosclerotic carotid plaques. For this application, images were recorded from 137 asymptomatic and 137 symptomatic plaques (symptoms are Stroke, Transient Ischaemic Attack (TIA), and Amaurosis Fugax (AF)). Two feature sets were extracted from the plaques; the first based on morphological image analysis and the second based on image texture analysis. Both sets were used in order to evaluate the performance of CPs on this problem. Four CPs were constructed using four popular classification methods, namely Artificial Neural Networks (ANNs), Support Vector Machines (SVMs), Naive Bayes Classification (NBC), and k -Nearest Neighbours. The results given by all CPs demonstrate the reliability and importance of the obtained confidence measures on the problem of stroke risk assessment.
Collapse
Affiliation(s)
- ANTONIS LAMBROU
- Computer Learning Research Centre, Royal Holloway, University of London, UK
| | | | | | | | - MARIOS S. PATTICHIS
- Electrical and Computer Engineering Department, University of New Mexico, New Mexico, USA
| | | | - ANDREW NICOLAIDES
- Imperial College London, UK
- Vascular screening and Diagnostic Centre, London, UK
- Cyprus Cardiovascular Disease Educational Research Trust, Nicosia, Cyprus
| |
Collapse
|
37
|
Acharya UR, Sree SV, Krishnan MMR, Molinari F, Saba L, Ho SYS, Ahuja AT, Ho SC, Nicolaides A, Suri JS. Atherosclerotic risk stratification strategy for carotid arteries using texture-based features. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:899-915. [PMID: 22502883 DOI: 10.1016/j.ultrasmedbio.2012.01.015] [Citation(s) in RCA: 91] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2011] [Revised: 01/15/2012] [Accepted: 01/20/2012] [Indexed: 05/31/2023]
Abstract
Plaques in the carotid artery result in stenosis, which is one of the main causes for stroke. Patients have to be carefully selected for stenosis treatments as they carry some risk. Since patients with symptomatic plaques have greater risk for strokes, an objective classification technique that classifies the plaques into symptomatic and asymptomatic classes is needed. We present a computer aided diagnostic (CAD) based ultrasound characterization methodology (a class of Atheromatic systems) that classifies the patient into symptomatic and asymptomatic classes using two kinds of datasets: (1) plaque regions in ultrasound carotids segmented semi-automatically and (2) far wall gray-scale intima-media thickness (IMT) regions along the common carotid artery segmented automatically. For both kinds of datasets, the protocol consists of estimating texture-based features in frameworks of local binary patterns (LBP) and Law's texture energy (LTE) and applying these features for obtaining the training parameters, which are then used for classification. Our database consists of 150 asymptomatic and 196 symptomatic plaque regions and 342 IMT wall regions. When using the Atheromatic-based system on semiautomatically determined plaque regions, support vector machine (SVM) classifier was adapted with highest accuracy of 83%. The accuracy registered was 89.5% on the far wall gray-scale IMT regions when using SVM, K-nearest neighbor (KNN) or radial basis probabilistic neural network (RBPNN) classifiers. LBP/LTE-based techniques on both kinds of carotid datasets are noninvasive, fast, objective and cost-effective for plaque characterization and, hence, will add more value to the existing carotid plaque diagnostics protocol. We have also proposed an index for each type of datasets: AtheromaticPi, for carotid plaque region, and AtheromaticWi, for IMT carotid wall region, based on the combination of the respective significant features. These indices show a separation between symptomatic and asymptomatic by 4.53 units and 4.42 units, respectively, thereby supporting the texture hypothesis classification.
Collapse
Affiliation(s)
- U Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore
| | | | | | | | | | | | | | | | | | | |
Collapse
|
38
|
Raman B, Raman R, Rubin GD, Napel S. Automated tracing of the adventitial contour of aortoiliac and peripheral arterial walls in CT angiography (CTA) to allow calculation of non-calcified plaque burden. J Digit Imaging 2012; 24:1078-86. [PMID: 21547519 DOI: 10.1007/s10278-011-9373-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Aortoiliac and lower extremity arterial atherosclerotic plaque burden is a risk factor for the development of visceral and peripheral ischemic and aneurismal vascular disease. While prior research allows automated quantification of calcified plaque in these body regions using CT angiograms, no automated method exists to quantify soft plaque. We developed an automatic algorithm that defines the outer wall contour and wall thickness of vessels to quantify non-calcified plaque in CT angiograms of the chest, abdomen, pelvis, and lower extremities. The algorithm encodes the search space as a constrained graph and calculates the outer wall contour by deriving a minimum cost path through the graph, following the visible outer wall contour while minimizing path tortuosity. Our algorithm was statistically equivalent to a reference standard made by two reviewers. Absolute error was 1.9 ± 2.3% compared to the inter-observer variability of 3.9 ± 3.6%. Wall thickness in vessels with atherosclerosis was 3.4 ± 1.6 mm compared to 1.2 ± 0.4 mm in normal vessels. The algorithm shows promise as a tool for quantification of non-calcified plaque in CT angiography. When combined with previous research, our method has the potential to quantify both non-calcified and calcified plaque in all clinically significant systemic arteries, from the thoracic aorta to the arteries of the calf, over a wide range of diameters. This algorithm has the potential to enable risk stratification of patients and facilitate investigations into the relationships between asymptomatic atherosclerosis and a variety of behavioral, physiologic, pathologic, and genotypic conditions.
Collapse
Affiliation(s)
- Bhargav Raman
- Department of Radiology, Stanford University School of Medicine, Stanford, CA 94305-5105, USA.
| | | | | | | |
Collapse
|
39
|
Acharya UR, S VS, M MRK, Saba L, Molinari F, Shafique S, Nicolaides A, Suri JS. Carotid far wall characterization using LBP, Laws' Texture Energy and wall variability: a novel class of Atheromatic systems. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2012:448-451. [PMID: 23365925 DOI: 10.1109/embc.2012.6345964] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
In this work, we present a Computer Aided Diagnostic (CAD) technique (a class of Atheromatic systems) that classifies the automatically segmented carotid far wall Intima-Media Thickness (IMT) regions along the common carotid artery into symptomatic and asymptomatic classes. We extracted texture features based on Local Binary Patterns (LBP) and Law's Texture Energy (LTE) and used the significant features to train and test the Support Vector Machine classifier. We developed the classifiers using three-fold stratified cross validation data resampling technique on 342 IMT wall regions. An accuracy of 89.5% was registered. Thus, the proposed technique is accurate, robust, non-invasive, fast, objective, and cost-effective, and hence, will add more value to the existing carotid plaque diagnostics protocol.
Collapse
Affiliation(s)
- U Rajendra Acharya
- Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore
| | | | | | | | | | | | | | | |
Collapse
|
40
|
Seabra J, Pedro LM, Fernandes E Fernandes J, Sanches J. Ultrasonographic characterization and identification of symptomatic carotid plaques. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2011; 2010:6110-3. [PMID: 21097136 DOI: 10.1109/iembs.2010.5627811] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Carotid plaques are the main cause of neurological symptoms due to distal embolization or flow reduction. An objective classification of such lesions into symptomatic or asymptomatic is crucial for optimal treatment planning.
Collapse
Affiliation(s)
- Jose Seabra
- Institute for Systems and Robotics, Technical Superior Institute, Av. Rovisco Pais, 1049-001 Lisbon, Portugal.
| | | | | | | |
Collapse
|
41
|
Acharya RU, Faust O, Alvin APC, Sree SV, Molinari F, Saba L, Nicolaides A, Suri JS. Symptomatic vs. Asymptomatic Plaque Classification in Carotid Ultrasound. J Med Syst 2011; 36:1861-71. [DOI: 10.1007/s10916-010-9645-2] [Citation(s) in RCA: 88] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2010] [Accepted: 12/20/2010] [Indexed: 12/01/2022]
|
42
|
Molinari F, Zeng G, Suri JS. A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2010; 100:201-221. [PMID: 20478640 DOI: 10.1016/j.cmpb.2010.04.007] [Citation(s) in RCA: 130] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2009] [Revised: 04/09/2010] [Accepted: 04/22/2010] [Indexed: 05/29/2023]
Abstract
Last 10 years have witnessed the growth of many computer applications for the segmentation of the vessel wall in ultrasound imaging. Epidemiological studies showed that the thickness of the major arteries is an early and effective marker of onset of cardiovascular diseases. Ultrasound imaging, being real-time, economic, reliable, safe, and now seems to become a standard in vascular assessment methodology. This review is an attempt to discuss the most performing methodologies that have been developed so far to perform computer-based segmentation and intima-media thickness (IMT) measurement of the carotid arteries in ultrasound images. First we will present the rationale and the clinical relevance of computer-based measurements in clinical practice, followed by the challenges that one has to face when approaching the segmentation of ultrasound vascular images. The core of the paper is the presentation, discussion, benchmarking and evaluation of different segmentation techniques, including: edge-detection, active contours, dynamic programming, local statistics, Hough transform, statistical modeling, and integration of these approaches. Also, we will discuss and compare the different performance metrics that have been proposed and used to perform the validation. Best performing user-dependent techniques show an average IMT measurement error of about 1μm when compared to human tracings [57], whereas completely automated techniques show errors of about 10μm. The review ends with a discussion about the current standards in carotid wall segmentation and in an overview of the future perspectives, which may include the adoption of advanced and intelligent strategies to let the computer technique measure the IMT in the image portion where measurement is more reliable.
Collapse
Affiliation(s)
- Filippo Molinari
- Biolab, Department of Electronics, Politecnico di Torino, Corso Duca degli Abruzzi 24, Turin, Italy.
| | | | | |
Collapse
|
43
|
Tsiaparas NN, Golemati S, Andreadis I, Stoitsis JS, Valavanis I, Nikita KS. Comparison of multiresolution features for texture classification of carotid atherosclerosis from B-mode ultrasound. ACTA ACUST UNITED AC 2010; 15:130-7. [PMID: 21075733 DOI: 10.1109/titb.2010.2091511] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In this paper, a multiresolution approach is suggested for texture classification of atherosclerotic tissue from B-mode ultrasound. Four decomposition schemes, namely, the discrete wavelet transform, the stationary wavelet transform, wavelet packets (WP), and Gabor transform (GT), as well as several basis functions, were investigated in terms of their ability to discriminate between symptomatic and asymptomatic cases. The mean and standard deviation of the detail subimages produced for each decomposition scheme were used as texture features. Feature selection included 1) ranking the features in terms of their divergence values and 2) appropriately thresholding by a nonlinear correlation coefficient. The selected features were subsequently input into two classifiers using support vector machines (SVM) and probabilistic neural networks. WP analysis and the coiflet 1 produced the highest overall classification performance (90% for diastole and 75% for systole) using SVM. This might reflect WP's ability to reveal differences in different frequency bands, and therefore, characterize efficiently the atheromatous tissue. An interesting finding was that the dominant texture features exhibited horizontal directionality, suggesting that texture analysis may be affected by biomechanical factors (plaque strains).
Collapse
Affiliation(s)
- Nikolaos N Tsiaparas
- Department of Electrical and Computer Engineering, National Technical University of Athens, Athens 15780, Greece.
| | | | | | | | | | | |
Collapse
|
44
|
A multifactorial analysis of obesity as CVD risk factor: use of neural network based methods in a nutrigenetics context. BMC Bioinformatics 2010; 11:453. [PMID: 20825661 PMCID: PMC2941694 DOI: 10.1186/1471-2105-11-453] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2009] [Accepted: 09/08/2010] [Indexed: 01/17/2023] Open
Abstract
Background Obesity is a multifactorial trait, which comprises an independent risk factor for cardiovascular disease (CVD). The aim of the current work is to study the complex etiology beneath obesity and identify genetic variations and/or factors related to nutrition that contribute to its variability. To this end, a set of more than 2300 white subjects who participated in a nutrigenetics study was used. For each subject a total of 63 factors describing genetic variants related to CVD (24 in total), gender, and nutrition (38 in total), e.g. average daily intake in calories and cholesterol, were measured. Each subject was categorized according to body mass index (BMI) as normal (BMI ≤ 25) or overweight (BMI > 25). Two artificial neural network (ANN) based methods were designed and used towards the analysis of the available data. These corresponded to i) a multi-layer feed-forward ANN combined with a parameter decreasing method (PDM-ANN), and ii) a multi-layer feed-forward ANN trained by a hybrid method (GA-ANN) which combines genetic algorithms and the popular back-propagation training algorithm. Results PDM-ANN and GA-ANN were comparatively assessed in terms of their ability to identify the most important factors among the initial 63 variables describing genetic variations, nutrition and gender, able to classify a subject into one of the BMI related classes: normal and overweight. The methods were designed and evaluated using appropriate training and testing sets provided by 3-fold Cross Validation (3-CV) resampling. Classification accuracy, sensitivity, specificity and area under receiver operating characteristics curve were utilized to evaluate the resulted predictive ANN models. The most parsimonious set of factors was obtained by the GA-ANN method and included gender, six genetic variations and 18 nutrition-related variables. The corresponding predictive model was characterized by a mean accuracy equal of 61.46% in the 3-CV testing sets. Conclusions The ANN based methods revealed factors that interactively contribute to obesity trait and provided predictive models with a promising generalization ability. In general, results showed that ANNs and their hybrids can provide useful tools for the study of complex traits in the context of nutrigenetics.
Collapse
|
45
|
Awad J, Krasinski A, Parraga G, Fenster A. Texture analysis of carotid artery atherosclerosis from three-dimensional ultrasound images. Med Phys 2010; 37:1382-91. [PMID: 20443459 DOI: 10.1118/1.3301592] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To quantitatively evaluate local carotid arterial statin effects in 3D US images using multiclassifier image texture analysis tools. METHODS Texture analysis tools were used to evaluate the effect of 80 mg atorvastatin administered daily to patients with carotid stenosis compared to those treated with placebo. Using three-dimensional carotid ultrasound images, 270 texture features from seven texture techniques were extracted from manually segmented carotid arteries based on the intima-media boundary [vessel wall (VW)]. Individual texture features were compared to the previously determined changes in VW volume (VWV) using the distance between classes, the Wilcoxon rank sum test, and accuracy of the classifiers. Texture features that resulted in maximal classification accuracy from each texture technique were selected using Pudil's sequential floating forward selection (SFFS) as a method of ranking each technique. Finally, SFFS-selected texture features from all texture techniques were used in combination with 24 classifier fusion techniques to improve classification accuracy. RESULTS Using the measurement of change in VWV, the distance between classes (DBC), Wilcoxon rank sum (WRS) p-value, and median accuracy measures (ACC) were 0.3798, 0.076, and 54.50%, respectively. Texture features improved the detection of statin-related changes using DBC to 0.5199, using WRS to 0.002, and ACC to 63.87%, respectively. The texture techniques that most differentiated between atorvastatin and placebo classes were Fourier power spectrum and Laws texture energy measures. The average classification accuracy between atorvastatin and placebo classes was improved from 57.22 +/- 12.11% using VWV to 97.87 +/- 3.93% using specific texture features. Furthermore, the use of specific texture features resulted in the average area under the receiver-operator characteristic curve (AUC) a value of 0.9988 +/- 0.0069 compared to 0.617 +/- 0.15 using carotid VWV. CONCLUSIONS Based on DBC, WRS, ACC, and AUC texture features derived from 3D carotid ultrasound were observed to be more sensitive in detecting statin-related changes in carotid atherosclerosis than VWV suggesting that texture classifiers can be used to detect changes in carotid atherosclerosis after therapy.
Collapse
Affiliation(s)
- Joseph Awad
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8, Canada.
| | | | | | | |
Collapse
|
46
|
Kyriacou EC, Pattichis C, Pattichis M, Loizou C, Christodoulou C, Kakkos SK, Nicolaides A. A review of noninvasive ultrasound image processing methods in the analysis of carotid plaque morphology for the assessment of stroke risk. ACTA ACUST UNITED AC 2010; 14:1027-38. [PMID: 20378477 DOI: 10.1109/titb.2010.2047649] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Noninvasive ultrasound imaging of carotid plaques allows for the development of plaque-image analysis methods associated with the risk of stroke. This paper presents several plaque-image analysis methods that have been developed over the past years. The paper begins with a review of clinical methods for visual classification that have led to standardized methods for image acquisition, describes methods for image segmentation and denoising, and provides an overview of the several texture-feature extraction and classification methods that have been applied. We provide a summary of emerging trends in 3-D imaging methods and plaque-motion analysis. Finally, we provide a discussion of the emerging trends and future directions in our concluding remarks.
Collapse
Affiliation(s)
- Efthyvoulos C Kyriacou
- Department of Computer Science and Engineering, Frederick University, CY-3080 Limassol, Cyprus.
| | | | | | | | | | | | | |
Collapse
|
47
|
Computer-aided Diagnosis Using Neural Networks and Support Vector Machines for Breast Ultrasonography. J Med Ultrasound 2009. [DOI: 10.1016/s0929-6441(09)60011-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
48
|
Efficacy of computer aided analysis in detection of significant coronary artery stenosis in cardiac using dual source computed tomography. Int J Cardiovasc Imaging 2008; 25:195-203. [DOI: 10.1007/s10554-008-9372-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2008] [Accepted: 09/09/2008] [Indexed: 01/26/2023]
|
49
|
Laws' masks descriptors applied to bone texture analysis: an innovative and discriminant tool in osteoporosis. Skeletal Radiol 2008; 37:541-8. [PMID: 18327577 DOI: 10.1007/s00256-008-0463-2] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2007] [Revised: 12/14/2007] [Accepted: 01/17/2008] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The objective of this study was to explore Laws' masks analysis to describe structural variations of trabecular bone due to osteoporosis on high-resolution digital radiographs and to check its dependence on the spatial resolution. Laws' masks are well established as one of the best methods for texture analysis in image processing and are used in various applications, but not in bone tissue characterisation. This method is based on masks that aim to filter the images. From each mask, five classical statistical parameters can be calculated. MATERIALS AND METHODS The study was performed on 182 healthy postmenopausal women with no fractures and 114 age-matched women with fractures [26 hip fractures (HFs), 29 vertebrae fractures (VFs), 29 wrist fractures (WFs) and 30 other fractures (OFs)]. For all subjects radiographs were obtained of the calcaneus with a new high-resolution X-ray device with direct digitisation (BMA, D3A, France). The lumbar spine, femoral neck, and total hip bone mineral density (BMD) were assessed by dual-energy X-ray absorptiometry. RESULTS In terms of reproducibility, the best results were obtained with the TRE5E5 mask, especially for three parameters: "mean", "standard deviation" and "entropy" with, respectively, in vivo mid-term root mean square average coefficient of variation (RMSCV)%= 1.79, 4.24 and 2.05. The "mean" and "entropy" parameters had a better reproducibility but "standard deviation" showed a better discriminant power. Thus, for univariate analysis, the difference between subjects with fractures and controls was significant (P<10(-3)) and significant for each fracture group independently (P<10(-4) for HF, P=0.025 for VF and P< 10(-3) for OF). After multivariate analysis with adjustment for age and total hip BMD, the difference concerning the "standard deviation" parameter remained statistically significant between the control group and the HF and VF groups (P<5 x 10(-5), and P=0.04, respectively). No significant correlation between these Laws' masks parameters and BMD was obtained. In addition, this study showed the dependence of Laws' masks parameters on image resolution, which confirms the necessity to perform Laws' textural measurement on high-resolution images. CONCLUSION The reproducibility and discriminant power of the Laws' masks analysis has been demonstrated on bone images; thus, this method constitutes a promising routine technique for the determination of osteoporosis fracture risk from radiographs.
Collapse
|
50
|
Zagrodsky V, Phelan M, Shekhar R. Automated detection of a blood pool in ultrasound images of abdominal trauma. ULTRASOUND IN MEDICINE & BIOLOGY 2007; 33:1720-6. [PMID: 17618042 DOI: 10.1016/j.ultrasmedbio.2007.05.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2006] [Revised: 04/25/2007] [Accepted: 05/18/2007] [Indexed: 05/16/2023]
Abstract
Ultrasound imaging is commonly used for emergency diagnosis of blunt trauma. Portable scanners are able to provide adequate imaging in remote and dangerous areas; however, medical expertise may not be available in the immediate local area to interpret the acquired images. The presence of pooled blood in the abdomen is a critical clinical symptom after trauma. This article describes an automated algorithm to detect blood pools in ultrasound images of abdominal trauma. The algorithm creates and uses a feature space consisting of local intensities, averaged local gradient magnitudes and second-order central rotation invariant moments. Successful tests were performed with a set of clinical images of a liver-kidney interface covering the Morrison's pouch, which is the most likely space for blood from an abdominal injury to gather. When implemented in a portable scanner, the reported algorithm will provide rapid, on-the-spot detection of trauma-induced blood pooling and advance notice of a significant blunt traumatic injury.
Collapse
Affiliation(s)
- Vladimir Zagrodsky
- Department of Biomedical Engineering, Lerner Research Institute, The Cleveland Clinic, Cleveland, OH, USA
| | | | | |
Collapse
|