1
|
Bae I, Kim BH. Drug release control and anti-inflammatory effect of biodegradable polymer surface modified by gas phase chemical functional reaction. Biomed Mater 2024; 19:025045. [PMID: 38364287 DOI: 10.1088/1748-605x/ad2a38] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 02/16/2024] [Indexed: 02/18/2024]
Abstract
The plasma technique has been widely used to modify the surfaces of materials. The purpose of this study was to evaluate the probability of controlling the prednisolone delivery velocity on a polylactic acid (PLA) surface modified by plasma surface treatment. Surface modification of PLA was performed at a low-pressure radio frequency under conditions of 100 W power, 50 mTorr chamber pressure, 100-200 sccm of flow rate, and Ar, O2, and CH4gases. The plasma surface-modified PLA was characterized using scanning emission microscope, x-ray photoelectron spectroscopy (XPS), and contact angle measurements.In vitroevaluations were performed to determine cellular response, drug release behavior, and anti-inflammatory effects. The PLA surface morphology was changed to a porous structure (with a depth of approximately 100 μm) and the surface roughness was also significantly increased. The XPS results demonstrated higher oxygenized carbon contents than those in the non-treated PLA group. The prednisolone holding capacity increased and the release was relatively prolonged in the surface-modified PLA group compared to that in the non-treated PLA group. In addition, cell migration and proliferation significantly increased after PLA treatment alone. The activity of cytokines such as cyclooxygenase-2 (COX-2), tumor necrosis factor-a (TNF-α), interleukin (IL-1β), and IL-6 were considerably reduced in the plasma-treated and prednisolone holding group. Taken together, surface-modified PLA by plasma can provide an alternative approach to conventional physicochemical approaches for sustained anti-inflammatory drug release.
Collapse
Affiliation(s)
- Inho Bae
- Convergence Research Center for Treatment of Oral Soft Tissue Disease (MRC), Chosun University, 2 Chosundae 4-gil, Dong-gu, Gwangju 61452, Republic of Korea
| | - Byung-Hoon Kim
- Convergence Research Center for Treatment of Oral Soft Tissue Disease (MRC), Chosun University, 2 Chosundae 4-gil, Dong-gu, Gwangju 61452, Republic of Korea
| |
Collapse
|
2
|
How to Sterilize Polylactic Acid Based Medical Devices? Polymers (Basel) 2021; 13:polym13132115. [PMID: 34203204 PMCID: PMC8271615 DOI: 10.3390/polym13132115] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 06/18/2021] [Accepted: 06/23/2021] [Indexed: 12/24/2022] Open
Abstract
How sterilization techniques accurately affect the properties of biopolymers continues to be an issue of discussion in the field of biomedical engineering, particularly now with the development of 3D-printed devices. One of the most widely used biopolymers in the manufacture of biomedical devices is the polylactic acid (PLA). Despite the large number of studies found in the literature on PLA devices, relatively few papers focus on the effects of sterilization treatments on its properties. It is well documented in the literature that conventional sterilization techniques, such as heat, gamma irradiation and ethylene oxide, can induced damages, alterations or toxic products release, due to the thermal and hydrolytical sensitivity of PLA. The purposes of this paper are, therefore, to review the published data on the most common techniques used to sterilize PLA medical devices and to analyse how they are affecting their physicochemical and biocompatible properties. Emerging and alternative sterilization methods for sensitive biomaterials are also presented.
Collapse
|
3
|
Laser-Activated Polymeric Microcapsules for Ultrasound Imaging and Therapy: In Vitro Feasibility. Biophys J 2017; 112:1894-1907. [PMID: 28494960 DOI: 10.1016/j.bpj.2017.03.033] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 03/16/2017] [Accepted: 03/27/2017] [Indexed: 11/23/2022] Open
Abstract
Polymeric microcapsules with a light-absorbing dye incorporated in their shell can generate vapor microbubbles that can be spatiotemporally controlled by pulsed laser irradiation. These contrast agents of 6-8 μm in diameter can circulate through the vasculature, offering possibilities for ultrasound (molecular) imaging and targeted therapies. Here, we study the impact of such vapor bubbles on human endothelial cells in terms of cell poration and cell viability to establish the imaging and therapeutic windows. Two capsule formulations were used: the first one consisted of a high boiling point oil (hexadecane), whereas the second was loaded with a low boiling point oil (perfluoropentane). Poration probability was already 40% for the smallest bubbles that were formed (<7.5 μm diameter), and reached 100% for the larger bubbles. The hexadecane-loaded capsules also produced bubbles while their shell remained intact. These encapsulated bubbles could therefore be used for noninvasive ultrasound imaging after laser activation without inducing any cell damage. The controlled and localized cell destruction achieved by activation of both capsule formulations may provide an innovative approach for specifically inducing cell death in vivo, e.g., for cancer therapy.
Collapse
|
4
|
Ignee A, Atkinson NSS, Schuessler G, Dietrich CF. Ultrasound contrast agents. Endosc Ultrasound 2016; 5:355-362. [PMID: 27824024 PMCID: PMC5206822 DOI: 10.4103/2303-9027.193594] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2016] [Accepted: 05/15/2016] [Indexed: 02/07/2023] Open
Abstract
Endoscopic ultrasound (EUS) plays an important role in imaging of the mediastinum and abdominal organs. Since the introduction of US contrast agents (UCA) for transabdominal US, attempts have been made to apply contrast-enhanced US techniques also to EUS. Since 2003, specific contrast-enhanced imaging was possible using EUS. Important studies have been published regarding contrast-enhanced EUS and the characterization of focal pancreatic lesions, lymph nodes, and subepithelial tumors. In this manuscript, we describe the relevant UCA, their application, and specific image acquisition as well as the principles of image tissue characterization using contrast-enhanced EUS. Safety issues, potential future developments, and EUS-specific issues are reviewed.
Collapse
Affiliation(s)
- Andre Ignee
- Department of Medical, Caritas-Krankenhaus, Bad Mergentheim, Germany
| | | | - Gudrun Schuessler
- Department of Medical, Caritas-Krankenhaus, Bad Mergentheim, Germany
| | | |
Collapse
|
5
|
Albala L, Ercan UK, Joshi SG, Eisenbrey JR, Teraphongphom N, Wheatley MA. Preservation of imaging capability in sensitive ultrasound contrast agents after indirect plasma sterilization. Int J Pharm 2015; 494:146-51. [PMID: 26241754 DOI: 10.1016/j.ijpharm.2015.07.064] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2015] [Revised: 05/24/2015] [Accepted: 07/26/2015] [Indexed: 12/14/2022]
Abstract
Many injectables are not amenable to standard sterilization methods, which destroy sensitive materials. This is particularly true for ultrasound contrast agents (UCA) consisting of gas bubbles stabilized by a surfactant or polymer shell. We investigated a new method to achieve safe and effective sterilization in production by introducing dielectric-barrier discharge non-thermal plasma. A dielectric-barrier discharge was generated to first produce plasma-treated phosphate-buffered saline (PTPBS), which was used as a sterilant solution for our UCA SE61, avoiding direct heat, pressure, chemicals, or radiation. Treated samples were tested for acoustic properties in vitro and in a flow phantom, and for sterility by standard methods. Three minutes plasma treatment of phosphate-buffered saline (PBS) proved effective. The samples showed significant inactivation of inoculated bacteria upon PTPBS treatment as compared to un-treated-PBS (p=0.0022). The treated and untreated samples showed no statistical significance (p>0.05) in acoustic response or bubble diameter (mean±SEM: 2.52±0.31 μm). Nile Red was used to model intercalation of drug in the hydrophobic shell, intercalated successfully into SE61, and was unaffected by plasma treatment. The PTPBS completely sterilized suspensions of UCA, and it did not compromise the acoustic properties of the agent or its ability to retain a hydrophobic compound.
Collapse
Affiliation(s)
- Lorenzo Albala
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA 19104, USA
| | - Utku K Ercan
- Department of Biomedical Engineering, Izmir Katip Celebi University, Izmir, Turkey
| | - Suresh G Joshi
- Center for Surgical Infection and Biofilm, Department of Microbiology & Immunology, College of Medicine, Drexel University, Philadelphia, PA 19102, USA
| | - John R Eisenbrey
- Department of Radiology, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Nutte Teraphongphom
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA 19104, USA
| | - Margaret A Wheatley
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA 19104, USA
| |
Collapse
|
6
|
Angilè F, Vargo KB, Sehgal CM, Hammer DA, Lee D. Recombinant protein-stabilized monodisperse microbubbles with tunable size using a valve-based microfluidic device. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2014; 30:12610-8. [PMID: 25265041 PMCID: PMC4211726 DOI: 10.1021/la502610c] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2014] [Revised: 08/21/2014] [Indexed: 05/05/2023]
Abstract
Microbubbles are used as contrast enhancing agents in ultrasound sonography and more recently have shown great potential as theranostic agents that enable both diagnostics and therapy. Conventional production methods lead to highly polydisperse microbubbles, which compromise the effectiveness of ultrasound imaging and therapy. Stabilizing microbubbles with surfactant molecules that can impart functionality and properties that are desirable for specific applications would enhance the utility of microbubbles. Here we generate monodisperse microbubbles with a large potential for functionalization by combining a microfluidic method and recombinant protein technology. Our microfluidic device uses an air-actuated membrane valve that enables production of monodisperse microbubbles with narrow size distribution. The size of microbubbles can be precisely tuned by dynamically changing the dimension of the channel using the valve. The microbubbles are stabilized by an amphiphilic protein, oleosin, which provides versatility in controlling the functionalization of microbubbles through recombinant biotechnology. We show that it is critical to control the composition of the stabilizing agents to enable formation of highly stable and monodisperse microbubbles that are echogenic under ultrasound insonation. Our protein-shelled microbubbles based on the combination of microfluidic generation and recombinant protein technology provide a promising platform for ultrasound-related applications.
Collapse
Affiliation(s)
- Francesco
E. Angilè
- Department
of Chemical and Biomolecular Engineering and Department of Bioengineering, School
of Engineering and Applied Science, University
of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Kevin B. Vargo
- Department
of Chemical and Biomolecular Engineering and Department of Bioengineering, School
of Engineering and Applied Science, University
of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Chandra M. Sehgal
- Department
of Radiology, University of Pennsylvania
Medical Center, Philadelphia, Pennsylvania 19104, United States
| | - Daniel A. Hammer
- Department
of Chemical and Biomolecular Engineering and Department of Bioengineering, School
of Engineering and Applied Science, University
of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Daeyeon Lee
- Department
of Chemical and Biomolecular Engineering and Department of Bioengineering, School
of Engineering and Applied Science, University
of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|
7
|
Valence SD, Tille JC, Chaabane C, Gurny R, Bochaton-Piallat ML, Walpoth BH, Möller M. Plasma treatment for improving cell biocompatibility of a biodegradable polymer scaffold for vascular graft applications. Eur J Pharm Biopharm 2014; 85:78-86. [PMID: 23958319 DOI: 10.1016/j.ejpb.2013.06.012] [Citation(s) in RCA: 72] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Revised: 06/06/2013] [Accepted: 06/12/2013] [Indexed: 11/25/2022]
Abstract
Biodegradable synthetic scaffolds are being evaluated by many groups for the application of vascular tissue engineering. In addition to the choice of the material and the structure of the scaffold, tailoring the surface properties can have an important effect on promoting adequate tissue regeneration. The objective of this study was to evaluate the effect of an increased hydrophilicity of a polycaprolactone vascular graft by treatment with a cold air plasma. To this end, treated and untreated scaffolds were characterized, evaluated in vitro with smooth muscle cells, and implanted in vivo in the rat model for 3 weeks, both in the subcutaneous location and as an aortic replacement. The plasma treatment significantly increased the hydrophilicity of the scaffold, with complete wetting after a treatment of 60 sec, but did not change fiber morphology or mechanical properties. Smooth muscle cells cultured on plasma treated patches adopt a spread out morphology compared to a small, rounded morphology on untreated patches. Subcutaneous implantation revealed a low foreign body reaction for both types of scaffolds and a more extended and dense cellular infiltrate in the plasma treated scaffolds. In the vascular position, the plasma treatment induced a better cellularization of the graft wall, while it did not affect endothelialization rate or intimal hyperplasia. Plasma treatment is therefore an accessible tool to easily increase the biocompatibility of a scaffold and accelerate tissue regeneration without compromising mechanical strength, which are valuable advantages for vascular tissue engineering.
Collapse
Affiliation(s)
- Sarra de Valence
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Geneva, Switzerland
| | | | | | | | | | | | | |
Collapse
|
8
|
|