Sundström E, Jiang M, Najm HK, Tretter JT. Blood Speckle Imaging: An Emerging Method for Perioperative Evaluation of Subaortic and Aortic Valvar Repair. Bioengineering (Basel) 2023; 10:1183. [PMID: 37892913 PMCID: PMC10604765 DOI: 10.3390/bioengineering10101183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/03/2023] [Accepted: 10/06/2023] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND This article presents the use of blood speckle Imaging (BSI) as an echocardiographic approach for the pre- and post-operative evaluation of subaortic membrane resection and aortic valve repair. METHOD BSI, employing block-matching algorithms, provided detailed visualization of flow patterns and quantification of parameters from ultrasound data. The 9-year-old patient underwent subaortic membrane resection and peeling extensions of the membrane from under the ventricular-facing surface of all three aortic valve leaflets. RESULT Post-operatively, BSI demonstrated improvements in hemodynamic patterns, where quantified changes in flow velocities showed no signs of stenosis and trivial regurgitation. The asymmetric jet with a shear layer and flow reversal on the posterior aspect of the aorta was corrected resulting in reduced wall shear stress on the anterior aspect and reduced oscillatory shear index, which is considered a contributing element in cellular alterations in the structure of the aortic wall. CONCLUSION This proof-of-concept study demonstrates the potential of BSI as an emerging echocardiographic approach for evaluating subaortic and aortic valvar repair. BSI enhances the quantitative evaluation of the left ventricular outflow tract of immediate surgical outcomes beyond traditional echocardiographic parameters and aids in post-operative decision-making. However, larger studies are needed to validate these findings and establish standardized protocols for clinical implementation.
Collapse
Affiliation(s)
- Elias Sundström
- Department of Engineering Mechanics, FLOW Research Center, KTH Royal Institute of Technology, Teknikringen 8, 100 44 Stockholm, Sweden
| | - Michael Jiang
- Department of Pediatric Cardiology, Cleveland Clinic, Cleveland, OH 44195, USA
| | - Hani K. Najm
- Congenital Valve Procedural Planning Center, Department of Pediatric Cardiology, Cleveland, OH 44195, USA
- Division of Pediatric Cardiac Surgery, and the Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, OH 44195, USA
| | - Justin T. Tretter
- Congenital Valve Procedural Planning Center, Department of Pediatric Cardiology, Cleveland, OH 44195, USA
- Division of Pediatric Cardiac Surgery, and the Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, OH 44195, USA
| |
Collapse
|
2
|
Park DC, Park DW. Ultrasound Speckle Decorrelation-Based Blood Flow Measurements. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1491-1498. [PMID: 37012098 DOI: 10.1016/j.ultrasmedbio.2023.03.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 02/20/2023] [Accepted: 03/03/2023] [Indexed: 05/17/2023]
Abstract
Ultrasound imaging is the preferred noninvasive technique to measure blood flow to diagnose cardiovascular disease such as heart failure, carotid stenosis, and renal failure. Conventional ultrasound techniques such as Doppler ultrasound, ultrasound imaging velocimetry, vector Doppler and transverse oscillation beamforming have been used for blood flow velocity profile measurement. However, these techniques were limited to measuring blood flow velocities within the 2-D lateral (across the ultrasound beam) plane of a vessel, and the blood flow velocity profile was derived by assuming that blood vessels have a circular cross-section with axis symmetry. This assumption is incorrect because most vessels have complex geometries, such as tortuosity and branches, and an asymmetric flow profile in the presence of vascular plaque. Consequently, ultrasound speckle decorrelation has been proposed to measure blood flow from transverse views of blood vessels wherein the ultrasound beam is perpendicular to the vessel axis. In this review, we present a summary of recent progress in ultrasound speckle decorrelation-based blood flow measurement techniques.
Collapse
Affiliation(s)
- Dong Chan Park
- Division of Convergence Technology, Research Institute and Hospital, National Cancer Center, Goyang, South Korea
| | - Dae Woo Park
- Division of Convergence Technology, Research Institute and Hospital, National Cancer Center, Goyang, South Korea.
| |
Collapse
|
3
|
Dong Y, Hong S, Song D, Liu M, Gao W, Du Y, Xu J, Dong F. Blood Flow Turbulence Quantification of Carotid Artery With a High-Frame Rate Vector Flow Imaging. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023; 42:427-436. [PMID: 35716339 DOI: 10.1002/jum.16039] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 04/17/2022] [Accepted: 05/27/2022] [Indexed: 06/15/2023]
Abstract
OBJECTIVES To assess the feasibility and performance of Turbulence (Tur) index as a quantitative tool for carotid artery flow turbulence; to detect and compare the blood flow patterns of common carotid artery (CCA) and carotid bulb (CB) at different ages and cardiac phases in healthy adults, and thus interpret the evolvement of etiology difference between CCA and CB. METHODS Carotid flow characteristics of 40 healthy volunteers were evaluated quantitatively by a high-frame rate vector flow imaging. Three types of flow patterns were defined depending on the distributive range of complex flow during systole in CB. Comparison of mean Tur value in CCA and CB at different age groups and cardiac phases was performed. And the correlation between Tur value and the diameter ratio of proximal internal carotid artery to common carotid artery (DRpro-ica/cca) was tested. RESULTS Mean Tur values in CB were remarkably higher than that in CCA, whether during systole or diastole (P < .001). Meanwhile Tur values in CB during systole were significantly higher than that during diastole (P < .001). Flow complexity of CB showed variations among 40 participants especially in systole, whereas the flow pattern of CCA was relatively consistent. Mean Tur values were positively correlated with DRpro-ica/cca in CB (ρ = 0.69, P < .05). CONCLUSIONS V Flow imaging provided a reliable method-Tur, for quantitative analysis of carotid blood flow. It had potential to be further applied in distinguishing complex hemodynamic characteristics in high-risk people of carotid diseases for the risk stratification of cardiovascular events.
Collapse
Affiliation(s)
- Yinghui Dong
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Shaofu Hong
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Di Song
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Mengmeng Liu
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Wenjing Gao
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Yigang Du
- Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Jinfeng Xu
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| | - Fajin Dong
- Department of Ultrasound, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China
| |
Collapse
|
4
|
Nahas H, Au JS, Ishii T, Yiu BYS, Chee AJY, Yu ACH. A Deep Learning Approach to Resolve Aliasing Artifacts in Ultrasound Color Flow Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:2615-2628. [PMID: 32746180 DOI: 10.1109/tuffc.2020.3001523] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Despite being used clinically as a noninvasive flow visualization tool, color flow imaging (CFI) is known to be prone to aliasing artifacts that arise due to fast blood flow beyond the detectable limit. From a visualization standpoint, these aliasing artifacts obscure proper interpretation of flow patterns in the image view. Current solutions for resolving aliasing artifacts are typically not robust against issues such as double aliasing. In this article, we present a new dealiasing technique based on deep learning principles to resolve CFI aliasing artifacts that arise from single- and double-aliasing scenarios. It works by first using two convolutional neural networks (CNNs) to identify and segment CFI pixel positions with aliasing artifacts, and then it performs phase unwrapping at these aliased pixel positions. The CNN for aliasing identification was devised as a U-net architecture, and it was trained with in vivo CFI frames acquired from the femoral bifurcation that had known presence of single- and double-aliasing artifacts. Results show that the segmentation of aliased CFI pixels was achieved successfully with intersection over union approaching 90%. After resolving these artifacts, the dealiased CFI frames consistently rendered the femoral bifurcation's triphasic flow dynamics over a cardiac cycle. For dealiased CFI pixels, their root-mean-squared difference was 2.51% or less compared with manual dealiasing. Overall, the proposed dealiasing framework can extend the maximum flow detection limit by fivefold, thereby improving CFI's flow visualization performance.
Collapse
|
5
|
Goddi A, Bortolotto C, Raciti MV, Fiorina I, Aiani L, Magistretti G, Sacchi A, Tinelli C, Calliada F. High-Frame Rate Vector Flow Imaging of the Carotid Bifurcation in Healthy Adults: Comparison With Color Doppler Imaging. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:2263-2275. [PMID: 29574932 DOI: 10.1002/jum.14579] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Revised: 11/07/2017] [Accepted: 12/09/2017] [Indexed: 06/08/2023]
Abstract
OBJECTIVES To evaluate the carotid bifurcation in healthy adults using a commercial system equipped with high-frame rate vector flow imaging (VFI) based on the plane wave and to compare VFI with color Doppler imaging. METHODS Carotid bifurcation diameters and flow characteristics of 60 vessels in 60 healthy volunteers were evaluated quantitatively and qualitatively to assess complex flow patterns and their extension and duration. RESULTS Complex flow in the internal carotid artery (ICA) was associated with a statistically significant difference in the ΔICA sinus-to-common carotid artery (CCA) diameter ratio (the relative change in diameter between the CCA and ICA sinus.) Vector flow imaging and color Doppler imaging were in accordance when detecting complex flow in 96.7% of cases; in 3.3% of cases, only VFI identified small recirculation areas of short duration. Vector flow imaging highlighted a larger extension of the complex flow (mean ± SD, 47.7 ± 28.5 mm2 ; median, 45.5 mm2 ) compared with color Doppler imaging (mean, 29.2 ± 19.9 mm2 ; median, 29.5 mm2 ) and better depicted different complex flow patterns; a strong correlation (r = 0.84) was found between the ΔICA sinus-to-CCA diameter ratio and the complex flow extension. Vector flow imaging showed a longer duration of the flow disturbances (mean, 380 ± 218 milliseconds; median, 352.5 milliseconds) compared with color Doppler imaging (mean, 325 ± 206 milliseconds; median, 333 milliseconds), and there was a strong correlation (r = 0.92). CONCLUSIONS Vector flow imaging is as effective as color Doppler imaging in the detection of flow disturbances, but it is more powerful in the assessment of complex flow patterns.
Collapse
Affiliation(s)
- Alfredo Goddi
- Centro Medico SME-Diagnostica per Immagini, Varese, Italy
| | - Chandra Bortolotto
- Radiology Unit, University of Pavia, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Policlinico San Matteo, Pavia, Italy
| | - Maria Vittoria Raciti
- Radiology Unit, University of Pavia, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Policlinico San Matteo, Pavia, Italy
| | - Ilaria Fiorina
- Radiology Unit, University of Pavia, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Policlinico San Matteo, Pavia, Italy
| | - Luca Aiani
- Centro Medico SME-Diagnostica per Immagini, Varese, Italy
| | | | - Andrea Sacchi
- Centro Medico SME-Diagnostica per Immagini, Varese, Italy
| | - Carmine Tinelli
- Clinical Epidemiology and Biometric Unit, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Policlinico San Matteo, Pavia, Italy
| | - Fabrizio Calliada
- Radiology Unit, University of Pavia, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Policlinico San Matteo, Pavia, Italy
| |
Collapse
|
6
|
Fekkes S, Saris AECM, Nillesen MM, Menssen J, Hansen HHG, de Korte CL. Simultaneous Vascular Strain and Blood Vector Velocity Imaging Using High-Frequency Versus Conventional-Frequency Plane Wave Ultrasound: A Phantom Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1166-1181. [PMID: 29993371 DOI: 10.1109/tuffc.2018.2834724] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Plaque strain and blood vector velocity imaging of stenosed arteries are expected to aid in diagnosis and prevention of cerebrovascular disease. Ultrafast plane wave imaging enables simultaneous strain and velocity estimation. Multiple ultrasound vendors are introducing high-frequency ultrasound probes and systems. This paper investigates whether the use of high-frequency ultrafast ultrasound is beneficial for assessing blood velocities and strain in arteries. The performance of strain and blood flow velocity estimation was compared between a high-frequency transducer (MS250, fc = 21 MHz) and a clinically utilized transducer (L12-5, fc = 9 MHz). Quantitative analysis based on straight tube phantom experiments revealed that the MS250 outperformed the L12-5 in the superficial region: low velocities near the wall were more accurately estimated and wall strains were better resolved. At greater than 2-cm echo depth, the L12-5 performed better due to the high attenuation of the MS250 probe. Qualitative comparison using a perfused patient-specific carotid bifurcation phantom confirmed these findings. Thus, in conclusion, for strain and blood velocity estimation for depths up to ~2 cm, a high-frequency probe is recommended.
Collapse
|
7
|
A PSF-Shape-Based Beamforming Strategy for Robust 2D Motion Estimation in Ultrafast Data. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8030429] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
8
|
High-frame rate vector flow imaging of the carotid bifurcation. Insights Imaging 2017; 8:319-328. [PMID: 28500487 PMCID: PMC5438320 DOI: 10.1007/s13244-017-0554-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Revised: 03/30/2017] [Accepted: 04/13/2017] [Indexed: 11/14/2022] Open
Abstract
Abstract Carotid artery atherosclerotic disease is still a significant cause of cerebrovascular morbidity and mortality. A new angle-independent technique, measuring and visualizing blood flow velocities in all directions, called vector flow imaging (VFI) is becoming available from several vendors. VFI can provide more intuitive and quantitative imaging of vortex formation, which is not clearly distinguishable in the color Doppler image. VFI, as quantitative method assessing disturbed flow patterns of the carotid bifurcation, has the potential to allow better understanding of the diagnostic value of complex flow and to enhance risk stratification. This pictorial review article will show which new information VFI adds for the knowledge of hemodynamics in comparison to the conventional ultrasound techniques. Teaching points • VFI is an angle-independent technique measuring flow velocities in all directions. • This kind of VFI is based on a plane wave multidirectional excitation technique. • VFI allows quantitative assessment of carotid streamlines progression and visualizes vorticity. • VFI does not allow a precise comprehension of streamlines’ 3D shape. • VFI allows a better understanding of carotid artery complex flows. Electronic supplementary material The online version of this article (doi:10.1007/s13244-017-0554-5) contains supplementary material, which is available to authorized users.
Collapse
|
9
|
Van Cauwenberge J, Lovstakken L, Fadnes S, Rodriguez-Morales A, Vierendeels J, Segers P, Swillens A. Assessing the Performance of Ultrafast Vector Flow Imaging in the Neonatal Heart via Multiphysics Modeling and In Vitro Experiments. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1772-1785. [PMID: 27824560 DOI: 10.1109/tuffc.2016.2596804] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Ultrafast vector flow imaging would benefit newborn patients with congenital heart disorders, but still requires thorough validation before translation to clinical practice. This paper investigates 2-D speckle tracking (ST) of intraventricular blood flow in neonates when transmitting diverging waves at ultrafast frame rate. Computational and in vitro studies enabled us to quantify the performance and identify artifacts related to the flow and the imaging sequence. First, synthetic ultrasound images of a neonate's left ventricular flow pattern were obtained with the ultrasound simulator Field II by propagating point scatterers according to 3-D intraventricular flow fields obtained with computational fluid dynamics (CFD). Noncompounded diverging waves (opening angle of 60°) were transmitted at a pulse repetition frequency of 9 kHz. ST of the B-mode data provided 2-D flow estimates at 180 Hz, which were compared with the CFD flow field. We demonstrated that the diastolic inflow jet showed a strong bias in the lateral velocity estimates at the edges of the jet, as confirmed by additional in vitro tests on a jet flow phantom. Furthermore, ST performance was highly dependent on the cardiac phase with low flows (<5 cm/s), high spatial flow gradients, and out-of-plane flow as deteriorating factors. Despite the observed artifacts, a good overall performance of 2-D ST was obtained with a median magnitude underestimation and angular deviation of, respectively, 28% and 13.5° during systole and 16% and 10.5° during diastole.
Collapse
|
10
|
Jensen JA, Nikolov SI, Yu ACH, Garcia D. Ultrasound Vector Flow Imaging-Part I: Sequential Systems. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1704-1721. [PMID: 27824555 DOI: 10.1109/tuffc.2016.2600763] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This paper gives a review of the most important methods for blood velocity vector flow imaging (VFI) for conventional sequential data acquisition. This includes multibeam methods, speckle tracking, transverse oscillation, color flow mapping derived VFI, directional beamforming, and variants of these. The review covers both 2-D and 3-D velocity estimation and gives a historical perspective on the development along with a summary of various vector flow visualization algorithms. The current state of the art is explained along with an overview of clinical studies conducted and methods for presenting and using VFI. A number of examples of VFI images are presented, and the current limitations and potential solutions are discussed.
Collapse
|
11
|
An Ultrasound Simulation Model for the Pulsatile Blood Flow Modulated by the Motion of Stenosed Vessel Wall. BIOMED RESEARCH INTERNATIONAL 2016; 2016:8502873. [PMID: 27478840 PMCID: PMC4958452 DOI: 10.1155/2016/8502873] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/14/2016] [Accepted: 06/01/2016] [Indexed: 11/17/2022]
Abstract
This paper presents an ultrasound simulation model for pulsatile blood flow, modulated by the motion of a stenosed vessel wall. It aims at generating more realistic ultrasonic signals to provide an environment for evaluating ultrasound signal processing and imaging and a framework for investigating the behaviors of blood flow field modulated by wall motion. This model takes into account fluid-structure interaction, blood pulsatility, stenosis of the vessel, and arterial wall movement caused by surrounding tissue's motion. The axial and radial velocity distributions of blood and the displacement of vessel wall are calculated by solving coupled Navier-Stokes and wall equations. With these obtained values, we made several different phantoms by treating blood and the vessel wall as a group of point scatterers. Then, ultrasound echoed signals from oscillating wall and blood in the axisymmetric stenotic-carotid arteries were computed by ultrasound simulation software, Field II. The results show better consistency with corresponding theoretical values and clinical data and reflect the influence of wall movement on the flow field. It can serve as an effective tool not only for investigating the behavior of blood flow field modulated by wall motion but also for quantitative or qualitative evaluation of new ultrasound imaging technology and estimation method of blood velocity.
Collapse
|
12
|
Swillens A, Shcherbakova D, Trachet B, Segers P. Pitfalls of Doppler Measurements for Arterial Blood Flow Quantification in Small Animal Research: A Study Based on Virtual Ultrasound Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:1399-1411. [PMID: 27004960 DOI: 10.1016/j.ultrasmedbio.2016.01.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2015] [Revised: 01/14/2016] [Accepted: 01/19/2016] [Indexed: 06/05/2023]
Abstract
High-resolution Doppler is a popular tool for evaluating cardiovascular physiology in mutant mice, though its 1-D nature and spectral broadening processes complicate interpretation of the measurement. Hence, it is crucial for pre-clinical researchers to know how error sources in Doppler assessments reveal themselves in the murine arterial system. Therefore, we performed virtual Doppler experiments in a computer model of an aneurysmatic murine aorta with full control of the imaging and insonified fluid dynamics. We observed significant variability in Doppler performance and derived vascular indices depending on the interrogated flow, operator settings and signal processing. In particular, we found that (i) Doppler spectra in the upper aortic branches and celiac artery exhibited more broadening because of complex out-of-beam flow paths; (ii) mean frequency tracking outperforms tracking of the outer envelope, but is sensitive to errors in angle correction; and (iii) imaging depths deviating much from the elevation focus suffer from decreased spectral quality.
Collapse
Affiliation(s)
- Abigail Swillens
- IbiTech-bioMMeda, Department of Electronics and Information Systems, Ghent University, Ghent, Belgium.
| | - Darya Shcherbakova
- IbiTech-bioMMeda, Department of Electronics and Information Systems, Ghent University, Ghent, Belgium
| | - Bram Trachet
- IbiTech-bioMMeda, Department of Electronics and Information Systems, Ghent University, Ghent, Belgium; Institute of Bioengineering, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland
| | - Patrick Segers
- IbiTech-bioMMeda, Department of Electronics and Information Systems, Ghent University, Ghent, Belgium
| |
Collapse
|
13
|
Fadnes S, Bjærum S, Torp H, Lovstakken L. Clutter filtering influence on blood velocity estimation using speckle tracking. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:2079-91. [PMID: 26670849 DOI: 10.1109/tuffc.2015.007247] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Blood speckle tracking has shown potential for solving the angle-dependency limitation in color flow imaging. However, as clutter filtering is still Doppler-based, flow velocities at near-perpendicular beam-to-flow angles can be severely attenuated. It is shown that the clutter filter also alters the speckle appearance through a decrease in the lateral imaging bandwidth, leading to poorer lateral resolution and thus tracking performance. Interestingly, at perpendicular beam-to-flow angles lateral band-pass characteristics are inferred, and the resulting lateral amplitude modulation could help improve tracking estimates. Simulations and flow phantom experiments showed that substantially improved results could be achieved by utilizing time-variant clutter filters (e.g., polynomial regression filters) despite the inherent decorrelation inferred by these filters, but only for higher ensemble sizes (N > 36). We found that, compared with color flow imaging, speckle tracking could yield consistent estimates well below the clutter filter cutoff, but with a higher variance attributed to the low signalto- noise ratio inferred by filter attenuation. Overall, provided that a low f-number and high ensemble lengths (N approx. > 36) can be used, speckle tracking can consistently provide angle- independent flow velocity estimates, limited only by a lower bound on the flow velocity itself.
Collapse
|
14
|
Leow CH, Bazigou E, Eckersley RJ, Yu ACH, Weinberg PD, Tang MX. Flow Velocity Mapping Using Contrast Enhanced High-Frame-Rate Plane Wave Ultrasound and Image Tracking: Methods and Initial in Vitro and in Vivo Evaluation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2913-2925. [PMID: 26275971 DOI: 10.1016/j.ultrasmedbio.2015.06.012] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2014] [Revised: 04/22/2015] [Accepted: 06/16/2015] [Indexed: 06/04/2023]
Abstract
Ultrasound imaging is the most widely used method for visualising and quantifying blood flow in medical practice, but existing techniques have various limitations in terms of imaging sensitivity, field of view, flow angle dependence, and imaging depth. In this study, we developed an ultrasound imaging velocimetry approach capable of visualising and quantifying dynamic flow, by combining high-frame-rate plane wave ultrasound imaging, microbubble contrast agents, pulse inversion contrast imaging and speckle image tracking algorithms. The system was initially evaluated in vitro on both straight and carotid-mimicking vessels with steady and pulsatile flows and in vivo in the rabbit aorta. Colour and spectral Doppler measurements were also made. Initial flow mapping results were compared with theoretical prediction and reference Doppler measurements and indicate the potential of the new system as a highly sensitive, accurate, angle-independent and full field-of-view velocity mapping tool capable of tracking and quantifying fast and dynamic flows.
Collapse
Affiliation(s)
- Chee Hau Leow
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Eleni Bazigou
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Robert J Eckersley
- Department of Biomedical Engineering, King's College London, London, United Kingdom
| | - Alfred C H Yu
- Medical Engineering Program, University of Hong Kong, Pokfulam, Hong Kong
| | - Peter D Weinberg
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Meng-Xing Tang
- Department of Bioengineering, Imperial College London, London, United Kingdom.
| |
Collapse
|
15
|
Fadnes S, Nyrnes SA, Torp H, Lovstakken L. Shunt flow evaluation in congenital heart disease based on two-dimensional speckle tracking. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:2379-2391. [PMID: 25023104 DOI: 10.1016/j.ultrasmedbio.2014.03.029] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2013] [Revised: 03/25/2014] [Accepted: 03/31/2014] [Indexed: 06/03/2023]
Abstract
High-frame-rate ultrasound speckle tracking was used for quantification of peak velocity in shunt flows resulting from septal defects in congenital heart disease. In a duplex acquisition scheme implemented on a research scanner, unfocused transmit beams and full parallel receive beamforming were used to achieve a frame rate of 107 frames/s for full field-of-view flow images with high accuracy, while also ensuring high-quality focused B-mode tissue imaging. The setup was evaluated in vivo for neonates with atrial and ventricular septal defects. The shunt position was automatically tracked in B-mode images and further used in blood speckle tracking to obtain calibrated shunt flow velocities throughout the cardiac cycle. Validation toward color flow imaging and pulsed wave Doppler with manual angle correction indicated that blood speckle tracking could provide accurate estimates of shunt flow velocities. The approach was less biased by clutter filtering compared with color flow imaging and was able to provide velocity estimates beyond the Nyquist range. Possible placements of sample volumes (and angle corrections) for conventional Doppler resulted in a peak shunt velocity variations of 0.49-0.56 m/s for the ventricular septal defect of patient 1 and 0.38-0.58 m/s for the atrial septal defect of patient 2. In comparison, the peak velocities found from speckle tracking were 0.77 and 0.33 m/s for patients 1 and 2, respectively. Results indicated that complex intraventricular flow velocity patterns could be quantified using high-frame-rate speckle tracking of both blood and tissue movement. This could potentially help increase diagnostic accuracy and decrease inter-observer variability when measuring peak velocity in shunt flows.
Collapse
Affiliation(s)
- Solveig Fadnes
- MI Lab and the Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway.
| | - Siri Ann Nyrnes
- MI Lab and the Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway; Department of Pediatrics, St. Olav's University Hospital, Trondheim, Norway
| | - Hans Torp
- MI Lab and the Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
| | - Lasse Lovstakken
- MI Lab and the Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
| |
Collapse
|
16
|
Yiu BYS, Lai SSM, Yu ACH. Vector projectile imaging: time-resolved dynamic visualization of complex flow patterns. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:2295-309. [PMID: 24972498 DOI: 10.1016/j.ultrasmedbio.2014.03.014] [Citation(s) in RCA: 112] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Revised: 03/02/2014] [Accepted: 03/10/2014] [Indexed: 05/22/2023]
Abstract
Achieving non-invasive, accurate and time-resolved imaging of vascular flow with spatiotemporal fluctuations is well acknowledged to be an ongoing challenge. In this article, we present a new ultrasound-based framework called vector projectile imaging (VPI) that can dynamically render complex flow patterns over an imaging view at millisecond time resolution. VPI is founded on three principles: (i) high-frame-rate broad-view data acquisition (based on steered plane wave firings); (ii) flow vector estimation derived from multi-angle Doppler analysis (coupled with data regularization and least-squares fitting); (iii) dynamic visualization of color-encoded vector projectiles (with flow speckles displayed as adjunct). Calibration results indicated that by using three transmit angles and three receive angles (-10°, 0°, +10° for both), VPI can consistently compute flow vectors in a multi-vessel phantom with three tubes positioned at different depths (1.5, 4, 6 cm), oriented at different angles (-10°, 0°, +10°) and of different sizes (dilated diameter: 2.2, 4.4 and 6.3 mm; steady flow rate: 2.5 mL/s). The practical merit of VPI was further illustrated through an anthropomorphic flow phantom investigation that considered both healthy and stenosed carotid bifurcation geometries. For the healthy bifurcation with 1.2-Hz carotid flow pulses, VPI was able to render multi-directional and spatiotemporally varying flow patterns (using a nominal frame rate of 416 fps or 2.4-ms time resolution). In the case of stenosed bifurcations (50% eccentric narrowing), VPI enabled dynamic visualization of flow jet and recirculation zones. These findings suggest that VPI holds promise as a new tool for complex flow analysis.
Collapse
Affiliation(s)
- Billy Y S Yiu
- Medical Engineering Program, University of Hong Kong, Pokfulam, Hong Kong
| | - Simon S M Lai
- Medical Engineering Program, University of Hong Kong, Pokfulam, Hong Kong
| | - Alfred C H Yu
- Medical Engineering Program, University of Hong Kong, Pokfulam, Hong Kong.
| |
Collapse
|