1
|
Puranda JL, Edwards CM, Weber VMR, Aboudlal M, Semeniuk K, Adamo KB. Validity of an ultrasound device to measure bone mineral density. Clin Anat 2025; 38:54-62. [PMID: 38877833 DOI: 10.1002/ca.24187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/02/2024] [Accepted: 05/04/2024] [Indexed: 06/16/2024]
Abstract
This study aims to examine the validity and reliability of the UltraScan650™, a portable ultrasound device, used to measure BMD at the 1/3rd radius position. Fifty-two female first responders and healthcare providers were assessed using DXA (forearm, femur, lumbar, and total body) and the UltraScan650™. Fat and lean mass were also assessed using the DXA. Pearson correlations, Bland-Altman plots, t-tests, and linear regressions were used to assess validity. Intra-class correlation (ICC) coefficients were used to assess reliability. Inter-rater reliability and repeatability were good (ICC = 0.896 [0.818; 0.942], p < 0.001) and excellent (ICC = 0.917 [0.785; 0.989], p < 0.001), respectively. BMD as measured by the UltraScan650™ was weakly correlated to the DXA (r = 0.382 [0.121; 0.593], p = 0.0052). Bland-Altman plots revealed that the UltraScan650™ underestimated BMD (-0.0569 g/cm2), this was confirmed with a significant paired t-test (p < 0.001). A linear regression was performed (0.4744 × UltraScan650™ + 0.4170) to provide more information as to the issue of agreement. Bland-Altman plots revealed a negligible bias, supported by a paired t-test (p = 0.9978). Pearson's correlation revealed a significant relationship (r = -0.771 [-0.862; -0.631], p < 0.0001) between adjusted UltraScan650™-DXA and the average of the two scans (i.e., adjusted UltraScan650™ and DXA), suggesting a proportional constant error and proportional constant variability in measurements of BMD from the UltraScan650™. The UltraScan650™ is not a valid alternative to DXA for diagnostic purposes; however, the UltraScan650™ could be used as a screening tool in the clinical and research setting given the linear transformation is employed.
Collapse
Affiliation(s)
- Jessica L Puranda
- School of Human Kinetics, Faculty of Health Sciences, University of Ottawa, Ottawa, Canada
| | - Chris M Edwards
- School of Human Kinetics, Faculty of Health Sciences, University of Ottawa, Ottawa, Canada
| | - Vinicius M R Weber
- Laboratory of Experimental and Applied Physiology to Physical Activity, Midwest State University of Paraná, Guarapuava, Paraná, Brazil
| | - Mohamed Aboudlal
- School of Human Kinetics, Faculty of Health Sciences, University of Ottawa, Ottawa, Canada
| | - Kevin Semeniuk
- School of Human Kinetics, Faculty of Health Sciences, University of Ottawa, Ottawa, Canada
| | - Kristi B Adamo
- School of Human Kinetics, Faculty of Health Sciences, University of Ottawa, Ottawa, Canada
| |
Collapse
|
2
|
Minonzio JG, Ramiandrisoa D, Schneider J, Kohut E, Streichhahn M, Stervbo U, Wirth R, Westhoff TH, Raum K, Babel N. Bi-Directional Axial Transmission measurements applied in a clinical environment. PLoS One 2022; 17:e0277831. [PMID: 36584002 PMCID: PMC9803229 DOI: 10.1371/journal.pone.0277831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Accepted: 11/03/2022] [Indexed: 12/31/2022] Open
Abstract
Accurate measurement of cortical bone parameters may improve fracture risk assessment and help clinicians on the best treatment strategy. Patients at risk of fracture are currently detected using the current X-Ray gold standard DXA (Dual XRay Absorptiometry). Different alternatives, such as 3D X-Rays, Magnetic Resonance Imaging or Quantitative Ultrasound (QUS) devices, have been proposed, the latter having advantages of being portable and sensitive to mechanical and geometrical properties. The objective of this cross-sectional study was to evaluate the performance of a Bi-Directional Axial Transmission (BDAT) device used by trained operators in a clinical environment with older subjects. The device, positioned at one-third distal radius, provides two velocities: VFAS (first arriving signal) and VA0 (first anti-symmetrical guided mode). Moreover, two parameters are obtained from an inverse approach: Ct.Th (cortical thickness) and Ct.Po (cortical porosity), along with their ratio Ct.Po/Ct.Th. The areal bone mineral density (aBMD) was obtained using DXA at the femur and spine. One hundred and six patients (81 women, 25 men) from Marien Hospital and St. Anna Hospital (Herne, Germany) were included in this study. Age ranged from 41 to 95 years, while body mass index (BMI) ranged from 16 to 47 kg.m-2. Three groups were considered: 79 non-fractured patients (NF, 75±13years), 27 with non-traumatic fractures (F, 80±9years) including 14 patients with non-vertebral fractures (NVF, 84±7years). Weak to moderate significant Spearman correlations (R ranging from 0.23 to 0.53, p < 0.05) were found between ultrasound parameters and age, BMI. Using multivariate Partial Least Square discrimination analyses with Leave-One-Out Cross-Validation (PLS-LOOCV), we found the combination of VFAS and the ratio Ct.Po/Ct.Th to be predictive for all non traumatic fractures (F) with the odds ratio (OR) equals to 2.5 [1.6-3.4] and the area under the ROC curve (AUC) equal to 0.63 [0.62-0.65]. For the group NVF, combination of four parameters VA0. Ct.Th, Ct.Po and Ct.Po/Ct.Po, along with age provides a discrimination model with OR and AUC equals to 7.5 [6.0-9.1] and 0.75 [0.73-0.76]. When restricted to a smaller population (87 patients) common to both BDAT and DXA, BDAT ORs and AUCs are comparable or slightly higher to values obtained with DXA. The fracture risk assessment by BDAT method in older patients, in a clinical setting, suggests the benefit of the affordable and transportable device for the routine use.
Collapse
Affiliation(s)
- Jean-Gabriel Minonzio
- Sorbonne Université, INSERM UMR S 1146, CNRS UMR 7371, Laboratoire d’Imagerie Biomédicale, Paris, France
- Escuela de Ingeniería Informática, Universidad de Valparaíso, Valparaíso, Chile
- Centro de Investigación y Desarrollo en Ingeniería en Salud, Universidad de Valparaíso, Valparaíso, Chile
- * E-mail:
| | | | - Johannes Schneider
- Berlin-Brandenburg School for Regenerative Therapies, Charité - Universitätsmedizin Berlin, Germany
| | - Eva Kohut
- Medical Clinic I, Marien Hospital Herne, Ruhr University, Bochum, Herne, Germany
| | - Melanie Streichhahn
- Medical Clinic I, Marien Hospital Herne, Ruhr University, Bochum, Herne, Germany
| | - Ulrik Stervbo
- Berlin-Brandenburg School for Regenerative Therapies, Charité - Universitätsmedizin Berlin, Germany
- Center for Translational Medicine and Immune Diagnostics Laboratory, Medical Department I, Marien Hospital Herne, Ruhr University, Bochum, Herne, Germany
| | - Rainer Wirth
- Department for Geriatric Medicine, Marien Hospital Herne, Ruhr University Bochum, Herne, Germany
| | - Timm Henning Westhoff
- Center for Translational Medicine and Immune Diagnostics Laboratory, Medical Department I, Marien Hospital Herne, Ruhr University, Bochum, Herne, Germany
| | - Kay Raum
- Berlin-Brandenburg School for Regenerative Therapies, Charité - Universitätsmedizin Berlin, Germany
| | - Nina Babel
- Berlin-Brandenburg School for Regenerative Therapies, Charité - Universitätsmedizin Berlin, Germany
- Center for Translational Medicine and Immune Diagnostics Laboratory, Medical Department I, Marien Hospital Herne, Ruhr University, Bochum, Herne, Germany
| |
Collapse
|
3
|
Clinical Devices for Bone Assessment. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:35-53. [DOI: 10.1007/978-3-030-91979-5_3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
4
|
Bochud N, Laugier P. Axial Transmission: Techniques, Devices and Clinical Results. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:55-94. [DOI: 10.1007/978-3-030-91979-5_4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
5
|
Armbrecht G, Nguyen Minh H, Massmann J, Raum K. Pore-Size Distribution and Frequency-Dependent Attenuation in Human Cortical Tibia Bone Discriminate Fragility Fractures in Postmenopausal Women With Low Bone Mineral Density. JBMR Plus 2021; 5:e10536. [PMID: 34761144 PMCID: PMC8567489 DOI: 10.1002/jbm4.10536] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 08/03/2021] [Indexed: 11/21/2022] Open
Abstract
Osteoporosis is a disorder of bone remodeling leading to reduced bone mass, structural deterioration, and increased bone fragility. The established diagnosis is based on the measurement of areal bone mineral density by dual‐energy X‐ray absorptiometry (DXA), which poorly captures individual bone loss and structural decay. Enlarged cortical pores in the tibia have been proposed to indicate structural deterioration and reduced bone strength in the hip. Here, we report for the first time the in vivo assessment of the cortical pore‐size distribution together with frequency‐dependent attenuation at the anteromedial tibia midshaft by means of a novel ultrasonic cortical backscatter (CortBS) technology. We hypothesized that the CortBS parameters are associated with the occurrence of fragility fractures in postmenopausal women (n = 55). The discrimination performance was compared with those of DXA and high‐resolution peripheral computed tomography (HR‐pQCT). The results suggest a superior discrimination performance of CortBS (area under the receiver operating characteristic curve [AUC]: 0.69 ≤ AUC ≤ 0.75) compared with DXA (0.54 ≤ AUC ≤ 0.55) and a similar performance compared with HR‐pQCT (0.66 ≤ AUC ≤ 0.73). CortBS is the first quantitative bone imaging modality that can quantify microstructural tissue deteriorations in cortical bone, which occur during normal aging and the development of osteoporosis. © 2021 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Gabriele Armbrecht
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Radiology, Center for Muscle and Bone Research Berlin Germany
| | - Huong Nguyen Minh
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Center for Regenerative Therapies Berlin Germany
| | - Jonas Massmann
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Center for Regenerative Therapies Berlin Germany
| | - Kay Raum
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Center for Regenerative Therapies Berlin Germany
| |
Collapse
|
6
|
Adami G, Arioli G, Bianchi G, Brandi ML, Caffarelli C, Cianferotti L, Gatti D, Girasole G, Gonnelli S, Manfredini M, Muratore M, Quarta E, Quarta L. Radiofrequency echographic multi spectrometry for the prediction of incident fragility fractures: A 5-year follow-up study. Bone 2020; 134:115297. [PMID: 32092480 DOI: 10.1016/j.bone.2020.115297] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 02/13/2020] [Accepted: 02/20/2020] [Indexed: 01/20/2023]
Abstract
PURPOSE To investigate the effectiveness of the T-score values provided by Radiofrequency Echographic Multi Spectrometry (REMS) in the identification of patients at risk for incident osteoporotic fractures. METHODS A population of Caucasian women (30-90 years), enrolled from 2013 to 2016, underwent dual X-ray absorptiometry (DXA) and REMS scans at axial sites. The incidence of fragility fractures was assessed during a follow-up period up to 5 years. Afterwards, patients with and without incident fractures were stratified in two age-matched groups with a 1: 2 proportion (Group F' and Group NF', respectively). The performance of REMS T-score in discriminating between the two groups was quantitatively assessed and compared with DXA. RESULTS 1516 patients were enrolled and 1370 completed the follow-up (mean ± SD: 3.7 ± 0.8 years; range: 1.9-5.0 years). Fracture incidence was 14.0%. Age-matched groups included 175 fractured patients and 350 non-fractured ones, respectively (median age 70.2 [interquartile range: 61.0-73.3] and 67.3 [65.4-69.8] years, p-value ns). The groups resulted also balanced for height, weight and BMI (p-values ns). As expected, the differences in REMS T-score (for vertebral site, -2.9 [-3.6 to -1.9] in Group F', -2.2 [-2.9 to -1.2] in Group NF') and DXA T-score (-2.8 [-3.3 to -1.9] in Group F', -2.2 [-2.9 to -1.4] in Group NF') were statistically significant (p-value <0.001). Analogous results were obtained for femoral neck. Considering the T-score cut-off of -2.5, REMS identified Group F' patients with a sensitivity of 65.1% and specificity of 57.7% of (OR = 2.6, 95%CI: 1.77-3.76, p < 0.001), whereas DXA showed a sensitivity of 57.1% and a specificity of 56.3% (OR = 1.7, 95%CI: 1.20-2.51, p-value = 0.0032). For femoral neck, REMS sensitivity and specificity were 40.2% and 79.9%, respectively, with an OR of 2.81 (95%CI: 1.80-4.39, p < 0.001). DXA, instead, showed a sensitivity and specificity of 42.3% and 79.3%, respectively, with an OR of 2.68 (95%CI: 1.71-4.21, p < 0.001). CONCLUSIONS REMS T-score resulted an effective predictor for the risk of incident fragility fractures in a population-based sample of female subjects, representing a promising parameter to enhance osteoporosis diagnosis in the clinical routine.
Collapse
Affiliation(s)
- Giovanni Adami
- Rheumatology Unit, Department of Medicine, University of Verona, Verona, Italy
| | - Giovanni Arioli
- Department of Neurosciences and Rehabilitation, "Carlo Poma" Hospital, ASST-Mantova, Mantova, Italy
| | | | - Maria Luisa Brandi
- Department of Experimental and Clinical Biomedical Sciences, University of Florence, Metabolic Bone Diseases Unit, University Hospital of Florence, Florence, Italy
| | - Carla Caffarelli
- Department of Medicine, Surgery and Neurosciences, University of Siena, Siena, Italy
| | - Luisella Cianferotti
- Department of Experimental and Clinical Biomedical Sciences, University of Florence, Metabolic Bone Diseases Unit, University Hospital of Florence, Florence, Italy
| | - Davide Gatti
- Rheumatology Unit, Department of Medicine, University of Verona, Verona, Italy
| | | | - Stefano Gonnelli
- Department of Medicine, Surgery and Neurosciences, University of Siena, Siena, Italy
| | - Monica Manfredini
- Department of Neurosciences and Rehabilitation, "Carlo Poma" Hospital, ASST-Mantova, Mantova, Italy
| | - Maurizio Muratore
- O.U. of Rheumatology, "Galateo" Hospital, San Cesario di Lecce ASL-LE, Lecce, Italy.
| | - Eugenio Quarta
- O.U. of Rheumatology, "Galateo" Hospital, San Cesario di Lecce ASL-LE, Lecce, Italy
| | - Laura Quarta
- O.U. of Rheumatology, "Galateo" Hospital, San Cesario di Lecce ASL-LE, Lecce, Italy
| |
Collapse
|
7
|
Abstract
PURPOSE OF REVIEW Patients with inflammatory arthropathies have a high rate of fragility fractures. Diagnostic assessment and monitoring of bone density and quality are therefore critically important. Here, we review standard and advanced techniques to measure bone density and quality, specifically focusing on patients with inflammatory arthropathies. RECENT FINDINGS Current standard procedures are dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT). DXA-based newer methods include trabecular bone score (TBS) and vertebral fracture assessment (VFA). More advanced imaging methods to measure bone quality include high-resolution peripheral quantitative computed tomography (HR-pQCT) as well as multi-detector CT (MD-CT) and magnetic resonance imaging (MRI). Quantitative ultrasound has shown promise but is not standard to assess bone fragility. While there are limitations, DXA remains the standard technique to measure density in patients with rheumatological disorders. Newer modalities to measure bone quality may allow better characterization of bone fragility but currently are not standard of care procedures.
Collapse
|
8
|
Minonzio JG, Bochud N, Vallet Q, Ramiandrisoa D, Etcheto A, Briot K, Kolta S, Roux C, Laugier P. Ultrasound-Based Estimates of Cortical Bone Thickness and Porosity Are Associated With Nontraumatic Fractures in Postmenopausal Women: A Pilot Study. J Bone Miner Res 2019; 34:1585-1596. [PMID: 30913320 DOI: 10.1002/jbmr.3733] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 02/21/2019] [Accepted: 03/10/2019] [Indexed: 01/02/2023]
Abstract
Recent ultrasound (US) axial transmission techniques exploit the multimode waveguide response of long bones to yield estimates of cortical bone structure characteristics. This pilot cross-sectional study aimed to evaluate the performance at the one-third distal radius of a bidirectional axial transmission technique (BDAT) to discriminate between fractured and nonfractured postmenopausal women. Cortical thickness (Ct.Th) and porosity (Ct.Po) estimates were obtained for 201 postmenopausal women: 109 were nonfractured (62.6 ± 7.8 years), 92 with one or more nontraumatic fractures (68.8 ± 9.2 years), 17 with hip fractures (66.1 ± 10.3 years), 32 with vertebral fractures (72.4 ± 7.9 years), and 17 with wrist fractures (67.8 ± 9.6 years). The areal bone mineral density (aBMD) was obtained using DXA at the femur and spine. Femoral aBMD correlated weakly, but significantly with Ct.Th (R = 0.23, p < 0.001) and Ct.Po (R = -0.15, p < 0.05). Femoral aBMD and both US parameters were significantly different between the subgroup of all nontraumatic fractures combined and the control group (p < 0.05). The main findings were that (1) Ct.Po was discriminant for all nontraumatic fractures combined (OR = 1.39; area under the receiver operating characteristic curve [AUC] equal to 0.71), for vertebral (OR = 1.96; AUC = 0.84) and wrist fractures (OR = 1.80; AUC = 0.71), whereas Ct.Th was discriminant for hip fractures only (OR = 2.01; AUC = 0.72); there was a significant association (2) between increased Ct.Po and vertebral and wrist fractures when these fractures were not associated with any measured aBMD variables; (3) between increased Ct.Po and all nontraumatic fractures combined independently of aBMD neck; and (4) between decreased Ct.Th and hip fractures independently of aBMD femur. BDAT variables showed comparable performance to that of aBMD neck with all types of fractures (OR = 1.48; AUC = 0.72) and that of aBMD femur with hip fractures (OR = 2.21; AUC = 0.70). If these results are confirmed in prospective studies, cortical BDAT measurements may be considered useful for assessing fracture risk in postmenopausal women. © 2019 American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- J-G Minonzio
- Laboratoire d'Imagerie Biomédicale, Sorbonne Université, CNRS, INSERM, Paris, France
| | - N Bochud
- Laboratoire d'Imagerie Biomédicale, Sorbonne Université, CNRS, INSERM, Paris, France
| | - Q Vallet
- Laboratoire d'Imagerie Biomédicale, Sorbonne Université, CNRS, INSERM, Paris, France
| | - D Ramiandrisoa
- Laboratoire d'Imagerie Biomédicale, Sorbonne Université, CNRS, INSERM, Paris, France
| | - A Etcheto
- Department of Rheumatology, Cochin Hospital, Epidemiology and Biostatistics Sorbonne Paris Cité, Research Center, INSERM U1153, Paris Descartes University, Paris, France
| | - K Briot
- Department of Rheumatology, Cochin Hospital, Epidemiology and Biostatistics Sorbonne Paris Cité, Research Center, INSERM U1153, Paris Descartes University, Paris, France
| | - S Kolta
- Department of Rheumatology, Cochin Hospital, Epidemiology and Biostatistics Sorbonne Paris Cité, Research Center, INSERM U1153, Paris Descartes University, Paris, France
| | - C Roux
- Department of Rheumatology, Cochin Hospital, Epidemiology and Biostatistics Sorbonne Paris Cité, Research Center, INSERM U1153, Paris Descartes University, Paris, France
| | - P Laugier
- Laboratoire d'Imagerie Biomédicale, Sorbonne Université, CNRS, INSERM, Paris, France
| |
Collapse
|
9
|
Vogl F, Friesenbichler B, Hüsken L, Kramers-de Quervain IA, Taylor WR. Can low-frequency guided waves at the tibia paired with machine learning differentiate between healthy and osteopenic/osteoporotic subjects? A pilot study. ULTRASONICS 2019; 94:109-116. [PMID: 30660337 DOI: 10.1016/j.ultras.2018.11.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Revised: 07/04/2018] [Accepted: 11/29/2018] [Indexed: 06/09/2023]
Abstract
PURPOSE Axial transmission quantitative acoustics (ax-QA) has shown to be a promising tool for assessing bone health and properties in a safe, inexpensive, and portable manner. This study investigated the efficacy of low-frequency ax-QA measured at the tibia, paired with a support vector machine (SVM) approach for combining multiple acoustic indicators, to diagnose osteoporosis as defined by bone mineral density. METHODS This pilot study measured 41 female subjects using ax-QA (flexural mode, 3 kHz) at the tibia and using dual X-ray absorptiometry (DXA) at the lumbar spine, femoral neck, and distal radius. For each location, a threshold classifier and SVM were trained to differentiate between healthy and non-healthy subjects based on the phase velocity at different frequencies. Receiver Operating Characteristics and area under curve values (AUC) were used to assess the classifiers' performances for various thresholds and class-weights. RESULTS The SVM outperformed the threshold classifier for all three bone locations at low false positive rates. While differentiation between healthy and non-healthy bone states was poor for the spine (AUC: 0.56 ± 0.04), good to moderate performances were observed for the radius (AUC: 0.83 ± 0.03) and hip (AUC: 0.71 ± 0.04). CONCLUSIONS Low-frequency ax-QA has demonstrated potential for complementing DXA in screening for osteoporosis at the radius and hip. Through further addition of acoustic indicators ax-QA could provide a diagnostic alternative in third-world countries, and bring bone health screening and monitoring into the hands of clinicians and general health practitioners everywhere.
Collapse
Affiliation(s)
- Florian Vogl
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland.
| | | | - Laura Hüsken
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | | | | |
Collapse
|
10
|
Pereira D, Haïat G, Fernandes J, Belanger P. Effect of intracortical bone properties on the phase velocity and cut-off frequency of low-frequency guided wave modes (20-85 kHz). THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:121. [PMID: 30710966 DOI: 10.1121/1.5084731] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Accepted: 12/05/2018] [Indexed: 06/09/2023]
Abstract
The assessment of intracortical bone properties is of interest since early-stage osteoporosis is associated with resorption in the endosteal region. However, understanding the interaction between ultrasonic guided waves and the cortical bone structure remains challenging. The purpose of this work is to investigate the effect of intracortical bone properties on the ultrasonic response obtained at low-frequency (<100 kHz) using an axial transmission configuration. The semi-analytical finite element method was used to simulate the propagation of guided waves in a waveguide with realistic geometry and material properties. An array of 20 receivers was used to calculate the phase velocity and cut-off frequency of the excited modes using the two-dimensional Fourier transform. The results show that the position of the emitter around the circumference of the bone is an important parameter to control since it can lead to variations of up to 10 dB in the amplitude of the transmitted modes. The cut-off frequency of the high order modes was, however, only slightly affected by the circumferential position of the emitter, and was sensitive mainly to the axial shear modulus. The phase velocity and cut-off frequency in the 20-85 kHz range are promising parameters for the assessment of intracortical properties.
Collapse
Affiliation(s)
- Daniel Pereira
- Department of Mechanical Engineering, École de Technologie Supérieure, 1100 Rue Notre-Dame O, Montreal, Quebec, H3C1K3, Canada
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multiechelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, Cretéil Cedex, 94010, France
| | - Julio Fernandes
- Centre de Recherche l'Hôpital du Sacré-Coeur de Montréal, 5400 Boul Gouin O, Montreal, Quebec, H4J1C5, Canada
| | - Pierre Belanger
- Department of Mechanical Engineering, École de Technologie Supérieure, 1100 Rue Notre-Dame O, Montreal, Quebec, H3C1K3, Canada
| |
Collapse
|
11
|
Choksi P, Jepsen KJ, Clines GA. The challenges of diagnosing osteoporosis and the limitations of currently available tools. Clin Diabetes Endocrinol 2018; 4:12. [PMID: 29862042 PMCID: PMC5975657 DOI: 10.1186/s40842-018-0062-7] [Citation(s) in RCA: 122] [Impact Index Per Article: 17.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Accepted: 04/27/2018] [Indexed: 02/07/2023] Open
Abstract
Dual-energy X-ray absorptiometry (DXA) was the first imaging tool widely utilized by clinicians to assess fracture risk, especially in postmenopausal women. The development of DXA nearly coincided with the availability of effective osteoporosis medications. Although osteoporosis in adults is diagnosed based on a T-score equal to or below − 2.5 SD, most individuals who sustain fragility fractures are above this arbitrary cutoff. This incongruity poses a challenge to clinicians to identify patients who may benefit from osteoporosis treatments. DXA scanners generate 2 dimensional images of complex 3 dimensional structures, and report bone density as the quotient of the bone mineral content divided by the bone area. An obvious pitfall of this method is that a larger bone will convey superior strength, but may in fact have the same bone density as a smaller bone. Other imaging modalities are available such as peripheral quantitative CT, but are largely research tools. Current osteoporosis medications increase bone density and reduce fracture risk but the mechanisms of these actions vary. Anti-resorptive medications (bisphosphonates and denosumab) primarily increase endocortical bone by bolstering mineralization of endosteal resorption pits and thereby increase cortical thickness and reduce cortical porosity. Anabolic medications (teriparatide and abaloparatide) increase the periosteal and endosteal perimeters without large changes in cortical thickness resulting in a larger more structurally sound bone. Because of the differences in the mechanisms of the various drugs, there are likely benefits of selecting a treatment based on a patient’s unique bone structure and pattern of bone loss. This review retreats to basic principles in order to advance clinical management of fragility fractures by examining how skeletal biomechanics, size, shape, and ultra-structural properties are the ultimate predictors of bone strength. Accurate measurement of these skeletal parameters through the development of better imaging scanners is critical to advancing fracture risk assessment and informing clinicians on the best treatment strategy. With this information, a “treat to target” approach could be employed to tailor current and future therapies to each patient’s unique skeletal characteristics.
Collapse
Affiliation(s)
- Palak Choksi
- 1Division of Metabolism, Endocrinology & Diabetes, Department of Internal Medicine, University of Michigan, Ann Arbor, MI USA
| | - Karl J Jepsen
- 2Departments of Orthopaedic Surgery and Biomedical Engineering, University of Michigan, Ann Arbor, MI USA
| | - Gregory A Clines
- 1Division of Metabolism, Endocrinology & Diabetes, Department of Internal Medicine, University of Michigan, Ann Arbor, MI USA.,Endocrinology Section, Ann Arbor VA Medical Center, 2215 Fuller Road, Research 151, Ann Arbor, MI 48105-2399 USA
| |
Collapse
|
12
|
Vallet Q, Bochud N, Chappard C, Laugier P, Minonzio JG. In Vivo Characterization of Cortical Bone Using Guided Waves Measured by Axial Transmission. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1361-1371. [PMID: 27392349 DOI: 10.1109/tuffc.2016.2587079] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Cortical bone loss is not fully assessed by the current X-ray methods, and there is an unmet need in identifying women at risk of osteoporotic fracture, who should receive a treatment. The last decade has seen the emergence of the ultrasound (US) axial transmission (AT) techniques to assess a cortical bone. Recent AT techniques exploit the multimode waveguide response of the long bones such as the radius. A recent ex vivo study by our group evidenced that a multimode AT approach can yield simultaneous estimates of cortical thickness (Ct.Th) and stiffness. The aim of this paper is to move one step forward to evaluate the feasibility of measuring multimode guided waves (GW) in vivo and to infer from it cortical thickness. Measurements were taken on the forearm of 14 healthy subjects with the goal to test the accuracy of the estimated thickness using the bidirectional AT method implemented on a dedicated 1-MHz linear US array. This setup allows determining in vivo the dispersion curves of GW transmitted in the cortical layer of the radius. An inverse procedure based on the comparison between the measured and modeled dispersion curves predicted by a 2-D transverse isotropic free plate waveguide model allowed an estimation of cortical thickness, despite the presence of soft tissue. The Ct.Th values were validated by comparison with the site-matched estimates derived from X-ray high-resolution peripheral quantitative computed tomography. Results showed a significant correlation between both measurements ( r2 = 0.7 , , and [Formula: see text] mm). This pilot study demonstrates the potential of bidirectional AT for the in vivo assessment of cortical thickness, a bone strength-related factor.
Collapse
|
13
|
Radial quantitative ultrasound and dual energy x-ray absorptiometry: intermethod agreement for bone status assessment in children. BIOMED RESEARCH INTERNATIONAL 2015; 2015:232876. [PMID: 25922831 PMCID: PMC4397423 DOI: 10.1155/2015/232876] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2014] [Accepted: 03/18/2015] [Indexed: 11/29/2022]
Abstract
Aim. To validate a radial quantitative ultrasound (QUS) system with dual energy X-ray absorptiometry (DXA), a criterion technique in bone status assessment among children. Methods. Bone health was evaluated using a radial QUS system (Sunlight Omnisense 8000P) to measure the speed of sound (SOS) at one-third distal radius of the nondominant hand and DXA (Hologic QDR) was used to assess whole body bone mineral density (BMD). Results. Some 29.9% of the children were grossly misclassified according to quartiles of BMD and radial SOS. Poor agreement was observed between Z-scores of radial SOS and whole-body BMD (mean difference = 0.6 ± 0.9; 95% limits of agreement = −1.4 to 2.6). With a cut-off value of −1.0, radial SOS yielded satisfactory sensitivity (80%) and specificity (93%) for the detection of children with low BMD. Conclusion. The observed poor agreement in the present study suggests that radial QUS and DXA are not comparable and hence are not interchangeable in evaluating bone status of the children.
Collapse
|
14
|
Tatarinov A, Egorov V, Sarvazyan N, Sarvazyan A. Multi-frequency axial transmission bone ultrasonometer. ULTRASONICS 2014; 54:1162-9. [PMID: 24206675 PMCID: PMC4205948 DOI: 10.1016/j.ultras.2013.09.025] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2013] [Revised: 08/12/2013] [Accepted: 09/01/2013] [Indexed: 05/23/2023]
Abstract
The last decade has seen a surge in the development of axial transmission QUS (Quantitative UltraSound) technologies for the assessment of long bones using various modes of acoustic waves. The condition of cortical bones and the development of osteoporosis are determined by numerous mechanical, micro-structural, and geometrical or macro-structural bone properties like hardness, porosity and cortical thickness. Such complex manifestations of osteoporosis require the evaluation of multiple parameters with different sensitivities to the various properties of bone that are affected by the disease. This objective may be achieved by using a multi-frequency ultrasonic examination The ratio of the acoustic wavelength to the cortical thickness can be changed by varying the frequency of the ultrasonic pulse propagating through the long bone that results in the change in composition of the induced wave comprised of a set of numerous modes of guided, longitudinal, and surface acoustic waves. The multi-frequency axial transmission QUS method developed at Artann Laboratories (Trenton, NJ) is implemented in the Bone Ultrasonic Scanner (BUSS). In the current version of the BUSS, a train of ultrasonic pulses with 60, 100, 400, 800, and 1200 kHz frequencies is used. The developed technology was tested on a variety of bone phantoms simulating normal, osteopenic, and osteoporotic bones. The results of this study confirm the feasibility of the multi-frequency approach for the assessment of the processes leading to osteoporosis.
Collapse
|
15
|
Egorov V, Tatarinov A, Sarvazyan N, Wood R, Magidenko L, Amin S, Khosla S, Ruh RJ, Ruh JM, Sarvazyan A. Osteoporosis detection in postmenopausal women using axial transmission multi-frequency bone ultrasonometer: clinical findings. ULTRASONICS 2014; 54:1170-7. [PMID: 24070826 PMCID: PMC3951708 DOI: 10.1016/j.ultras.2013.08.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2013] [Revised: 08/22/2013] [Accepted: 08/30/2013] [Indexed: 05/07/2023]
Abstract
The objective of this study was to evaluate if the Bone UltraSonic Scanner (BUSS) can detect osteoporosis in postmenopausal women. BUSS is an axial transmission multi-frequency ultrasonometer for acquisition of wave propagation profiles along the proximal anterior tibia. We derived 10 diagnostically significant BUSS parameters that were then compared with the DXA spine T-score, which was used in this study as the "gold standard" for the assessment of osteoporosis (T-score<-2.5). BUSS wave parameters were studied in 331 postmenopausal women examined by 9 trained operators at 3 clinical sites with use of 3 devices. The efficiency of each BUSS parameter in osteoporosis detection was assessed using a receiver operating characteristic curve analysis. Area under the curve (AUC) for each of 10 parameters ranged from 58.1% to 70.2%. Using these parameters a linear classifier was derived which provided at its output 83.0% AUC, 87.7% sensitivity and 63.2% specificity to DXA-identified osteoporosis. The results of this study confirm BUSS's capability to detect osteoporosis in postmenopausal women.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Richard J Ruh
- Catholic Health, Sisters of Charity Hospital, Buffalo, NY 14214, USA
| | - Jennifer M Ruh
- Catholic Health, Sisters of Charity Hospital, Buffalo, NY 14214, USA
| | | |
Collapse
|
16
|
Rohde K, Rohrbach D, Glüer CC, Laugier P, Grimal Q, Raum K, Barkmann R. Influence of porosity, pore size, and cortical thickness on the propagation of ultrasonic waves guided through the femoral neck cortex: a simulation study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:302-313. [PMID: 24474136 DOI: 10.1109/tuffc.2014.6722615] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The femoral neck is a common fracture site in elderly people. The cortical shell is thought to be the major contributor to the mechanical competence of the femoral neck, but its microstructural parameters are not sufficiently accessible under in vivo conditions with current X-ray-based methods. To systematically investigate the influences of pore size, porosity, and thickness of the femoral neck cortex on the propagation of ultrasound, we developed 96 different bone models (combining 6 different pore sizes with 4 different porosities and 4 different thicknesses) and simulated the ultrasound propagation using a finite-difference time-domain algorithm. The simulated single-element emitter and receiver array consisting of 16 elements (8 inferior and 8 superior) were placed at anterior and posterior sides of the bone, respectively (transverse transmission). From each simulation, we analyzed the waveform collected by each of the inferior receiver elements for the one with the shortest time of flight. The first arriving signal of this waveform, which is associated with the wave traveling through the cortical shell, was then evaluated for its three different waveform characteristics (TOF: time point of the first point of inflection of the received signal, Δt: difference between the time point at which the signal first crosses the zero baseline and TOF, and A: amplitude of the first extreme of the first arriving signal). From the analyses of these waveform characteristics, we were able to develop multivariate models to predict pore size, porosity, and cortical thickness, corresponding to the 96 different bone models, with remaining errors in the range of 50 μm for pore size, 1.5% for porosity, and 0.17 mm for cortical thickness.
Collapse
|