1
|
Mishra A, Cleveland RO. Agarose as a Tissue Mimic for the Porcine Heart, Kidney, and Liver: Measurements and a Springpot Model. Bioengineering (Basel) 2024; 11:589. [PMID: 38927825 PMCID: PMC11200806 DOI: 10.3390/bioengineering11060589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/27/2024] [Accepted: 06/04/2024] [Indexed: 06/28/2024] Open
Abstract
Agarose gels are often used as a tissue mimic. The goal of this work was to determine the appropriate agarose concentrations that result in mechanical properties that match three different porcine organs. Strain tests were carried out with an amplitude varying from 0.01% to 10% at a frequency of 1 Hz on a range of agarose concentrations and porcine organs. Frequency sweep tests were performed from 0.1 Hz to a maximum of 9.5 Hz at a shear strain amplitude of 0.1% for agarose and porcine organs. In agarose samples, the effect of pre-compression of the samples up to 10% axial strain was considered during frequency sweep tests. The experimental measurements from agarose samples were fit to a fractional order viscoelastic (springpot) model. The model was then used to predict stress relaxation in response to a step strain of 0.1%. The prediction was compared to experimental relaxation data, and the results agreed within 12%. The agarose concentrations (by mass) that gave the best fit were 0.25% for the liver, 0.3% for the kidney, and 0.4% for the heart. At a frequency of 0.1 Hz and a shear strain of 0.1%, the agarose concentrations that best matched the shear storage modulus of the porcine organs were 0.4% agarose for the heart, 0.3% agarose for the kidney, and 0.25% agarose for the liver.
Collapse
Affiliation(s)
| | - Robin O. Cleveland
- Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK;
| |
Collapse
|
2
|
Staes J, Fade J. Optimized Stokes imaging for highly resolved optical speckle fields, Part III: topological analysis of polarimetric state distributions with optimized data representations. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2024; 41:811-823. [PMID: 38856567 DOI: 10.1364/josaa.516717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 03/09/2024] [Indexed: 06/11/2024]
Abstract
In this last article of a three-paper series focusing on Stokes polarimetry of optical speckle fields resolved at the individual speckle grain scale, experimental results are provided on test samples of varying nature and polarization properties, and are analyzed extensively. For this purpose, a review of the classical ways of displaying Stokes polarimetric information is provided. Then, some original alternative graphical representations are introduced that ensure optimal readability and interpretability of the Stokes imaging data in the context of speckle field polarimetry, and it is shown how they can be adapted to various observation scales. Finally, these tools are implemented in order to provide a topological analysis of the distribution of the states of polarization across a speckle pattern, and in the vicinity of polarimetric singularities of the field.
Collapse
|
3
|
Torres J, Callejas A, Gomez A, Rus G. Optical micro-elastography with magnetic excitation for high frequency rheological characterization of soft media. ULTRASONICS 2023; 132:107021. [PMID: 37141701 DOI: 10.1016/j.ultras.2023.107021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 03/22/2023] [Accepted: 04/18/2023] [Indexed: 05/06/2023]
Abstract
The propagation of shear waves in elastography at high frequency (>3 kHz) in viscoelastic media has not been extensively studied due to the high attenuation and technical limitations of current techniques. An optical micro-elastography (OME) technique using magnetic excitation for generating and tracking high frequency shear waves with enough spatial and temporal resolution was proposed. Ultrasonics shear waves (above 20 kHz) were generated and observed in polyacrylamide samples. A cutoff frequency, from where the waves no longer propagate, was observed to vary depending on the mechanical properties of the samples. The ability of the Kelvin-Voigt (KV) model to explain the high cutoff frequency was investigated. Two alternative measurement techniques, Dynamic Mechanical Analysis (DMA) and Shear Wave Elastography (SWE), were used to complete the whole frequency range of the velocity dispersion curve while avoid capturing guided waves in the low frequency range (<3 kHz). The combination of the three measurement techniques provided rheology information from quasi-static to ultrasonic frequency range. A key observation was that the full frequency range of the dispersion curve was necessary if one wanted to infer accurate physical parameters from the rheological model. By comparing the low frequency range with the high frequency range, the relative errors for the viscosity parameter could reach 60 % and they could be higher with higher dispersive behavior. The high cutoff frequency may be predicted in materials that follow a KV model over their entire measurable frequency range. The mechanical characterization of cell culture media could benefit from the proposed OME technique.
Collapse
Affiliation(s)
- Jorge Torres
- Ultrasonics Lab (TEP-959), Department of Structural Mechanics, University of Granada, Granada 18071, Spain; TEC-12 group, Instituto de Investigación Biosanitaria, ibs.Granada 18001, Spain.
| | - Antonio Callejas
- Ultrasonics Lab (TEP-959), Department of Structural Mechanics, University of Granada, Granada 18071, Spain; TEC-12 group, Instituto de Investigación Biosanitaria, ibs.Granada 18001, Spain
| | - Antonio Gomez
- Department of Mechanical Engineering, University College London, London WC1E 6BT, UK
| | - Guillermo Rus
- Ultrasonics Lab (TEP-959), Department of Structural Mechanics, University of Granada, Granada 18071, Spain; TEC-12 group, Instituto de Investigación Biosanitaria, ibs.Granada 18001, Spain; Excellence Research Unit "ModelingNature" (MNat), Universidad de Granada, Granada 18001, Spain
| |
Collapse
|
4
|
A Cost-Effective Reusable Tissue Mimicking Phantom for High Intensity Focused Ultrasonic Liver Surgery. BIOENGINEERING (BASEL, SWITZERLAND) 2022; 9:bioengineering9120786. [PMID: 36550992 PMCID: PMC9774244 DOI: 10.3390/bioengineering9120786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 11/24/2022] [Accepted: 12/06/2022] [Indexed: 12/14/2022]
Abstract
A polyacrylamide polysaccharide hydrogel (PASG) containing a nonionic surfactant of the polyoxyethylene nonylphenyl ethers series (NP14) has been adapted to the fabrication of a reusable cost-effective ultrasonic tissue-mimicking phantom for real-time visualization of the thermal lesions by high intensity focused ultrasound (HIFU) irradiation. The constructed NP14 (40% in w/v) PASG is optically transparent at room temperatures, and it turns out to be opaque white as heated over the clouding points of about 55 °C and returns to its original transparent state after cooling. The acoustic property of the proposed phantom is similar to those of human liver tissues, which includes the acoustic impedance of 1.68 Mrayls, the speed of sound of 1595 ± 5 m/s, the attenuation coefficient of 0.52 ± 0.05 dB cm-1 (at 1 MHz), the backscatter coefficient of 0.21 ± 0.09 × 10-3 sr-1 cm-1 (at 1 MHz), and the nonlinear parameter B/A of 6.4 ± 0.2. The NP14-PASG was tested to assess the characteristic information (sizes, shapes, and locations) of the thermal lesions visualized when exposed to typical HIFU fields (1.1 MHz, focal pressure up to 20.1 MPa, focal intensity 4075 W/cm2). The proposed NP14-PASG is expected to replace the existing costly BSA-PASG used for more effective testing of the performance of therapeutic ultrasonic devices based on thermal mechanisms.
Collapse
|
5
|
Mori T, Ishikawa N, Mimura H. Bioequivalent and Non-Aqueous Polyurethane Gel for Ultrasound Phantom. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN 2022. [DOI: 10.1252/jcej.21we117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Takato Mori
- Cooperative Major in Medical Photonics, Shizuoka University
| | - Naoto Ishikawa
- Manufacturing Department, Manufacturing Devision2, Kyoto Kagaku Co., Ltd
| | | |
Collapse
|
6
|
Nanda Kumar Y, Singh Z, Wang YN, Schade GR, Kreider W, Bruce M, Vlaisavljevich E, Khokhlova TD, Maxwell AD. Development of Tough Hydrogel Phantoms to Mimic Fibrous Tissue for Focused Ultrasound Therapies. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1762-1777. [PMID: 35697582 PMCID: PMC9357045 DOI: 10.1016/j.ultrasmedbio.2022.05.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 04/28/2022] [Accepted: 05/02/2022] [Indexed: 05/30/2023]
Abstract
Tissue-mimicking gels provide a cost-effective medium to optimize histotripsy treatment parameters with immediate feedback. Agarose and polyacrylamide gels are often used to evaluate treatment outcomes as they mimic the acoustic properties and stiffness of a variety of soft tissues, but they do not exhibit high toughness, a characteristic of fibrous connective tissue. To mimic pathologic fibrous tissue found in benign prostate hyperplasia (BPH) and other diseases that are potentially treatable with histotripsy, an optically transparent hydrogel with high toughness was developed that is a hybrid of polyacrylamide and alginate. The stiffness was established using shear wave elastography (SWE) and indentometry techniques and was found to be representative of human BPH ex vivo prostate tissue. Different phantom compositions and excised ex vivo BPH tissue samples were treated with a 700-kHz histotripsy transducer at different pulse repetition frequencies. Post-treatment, the hybrid gels and the tissue samples exhibited differential reduction in stiffness as measured by SWE. On B-mode ultrasound, partially treated areas were present as hyperechoic zones and fully liquified areas as hypoechoic zones. Phase contrast microscopy of the gel samples revealed liquefaction in regions consistent with the target lesion dimensions and correlated to findings identified in tissue samples via histology. The dose required to achieve liquefaction in the hybrid gel was similar to what has been observed in ex vivo tissue and greater than that of agarose of comparable or higher Young's modulus by a factor >10. These results indicate that the developed hydrogels closely mimic elasticities found in BPH prostate ex vivo tissue and have a similar response to histotripsy treatment, thus making them a useful cost-effective alternative for developing and evaluating different treatment protocols.
Collapse
Affiliation(s)
- Yashwanth Nanda Kumar
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA.
| | - Zorawar Singh
- Department of Urology, University of Washington School of Medicine, Seattle, Washington, USA
| | - Yak-Nam Wang
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - George R Schade
- Department of Urology, University of Washington School of Medicine, Seattle, Washington, USA
| | - Wayne Kreider
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - Matthew Bruce
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Tatiana D Khokhlova
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA; Department of Gastroenterology, University of Washington School of Medicine, Seattle, Washington, USA
| | - Adam D Maxwell
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA; Department of Urology, University of Washington School of Medicine, Seattle, Washington, USA
| |
Collapse
|
7
|
Zhong X, Cao Y, Zhou P. Thermochromic Tissue-Mimicking Phantoms for Thermal Ablation Based on Polyacrylamide Gel. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1361-1372. [PMID: 35623921 DOI: 10.1016/j.ultrasmedbio.2022.03.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 03/29/2022] [Accepted: 03/30/2022] [Indexed: 06/15/2023]
Abstract
In recent years, thermal ablation has played an increasingly important role in treating various tumors in the clinic. A practical thermochromic phantom model can provide a favorable platform for clinical thermotherapy training of young physicians or calibration and optimization of thermal devices without risk to animals or human participants. To date, many tissue-mimicking thermal phantoms have been developed and are well liked, especially the polyacrylamide gel (PAG)-based phantoms. This review summarizes the PAG-based phantoms in the field of thermotherapy, details their advantages and disadvantages and provides a direction for further optimization. The relevant physical parameters (such as electrical, acoustic, and thermal properties) of these phantoms are also presented in this review, which can assist operators in a deeper understanding of these phantoms and selection of the proper recipes for phantom fabrication.
Collapse
Affiliation(s)
- Xinyu Zhong
- Department of Ultrasound, Third Xiangya Hospital, Central South University, Changsha, Hunan, China
| | - Yuting Cao
- Institute of Ultrasound Imaging & Department of Ultrasound, Second Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ultrasound Molecular Imaging, Chongqing, China
| | - Ping Zhou
- Department of Ultrasound, Third Xiangya Hospital, Central South University, Changsha, Hunan, China.
| |
Collapse
|
8
|
Jandhyala S, Van Namen A, Spatarelu CP, Luke GP. EGFR-Targeted Perfluorohexane Nanodroplets for Molecular Ultrasound Imaging. NANOMATERIALS 2022; 12:nano12132251. [PMID: 35808089 PMCID: PMC9268413 DOI: 10.3390/nano12132251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 06/27/2022] [Accepted: 06/28/2022] [Indexed: 02/01/2023]
Abstract
Perfluorocarbon nanodroplets offer an alternative to gaseous microbubbles as contrast agents for ultrasound imaging. They can be acoustically activated to induce a liquid-to-gas phase transition and provide contrast in ultrasound images. In this study, we demonstrate a new strategy to synthesize antibody-conjugated perfluorohexane nanodroplet (PFHnD-Ab) ultrasound contrast agents that target cells overexpressing the epidermal growth factor receptor (EGFR). The perfluorohexane nanodroplets (PFHnD) containing a lipophilic DiD fluorescent dye were synthesized using a phospholipid shell. Antibodies were conjugated to the surface through a hydrazide-aldehyde reaction. Cellular binding was confirmed using fluorescence microscopy; the DiD fluorescence signal of the PFHnD-Ab was 5.63× and 6× greater than the fluorescence signal in the case of non-targeted PFHnDs and the EGFR blocking control, respectively. Cells were imaged in tissue-mimicking phantoms using a custom ultrasound imaging setup consisting of a high-intensity focused ultrasound transducer and linear array imaging transducer. Cells with conjugated PFHnD-Abs exhibited a significantly higher (p < 0.001) increase in ultrasound amplitude compared to cells with non-targeted PFHnDs and cells exposed to free antibody before the addition of PFHnD-Abs. The developed nanodroplets show potential to augment the use of ultrasound in molecular imaging cancer diagnostics.
Collapse
Affiliation(s)
- Sidhartha Jandhyala
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA; (S.J.); (A.V.N.); (C.-P.S.)
| | - Austin Van Namen
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA; (S.J.); (A.V.N.); (C.-P.S.)
| | - Catalina-Paula Spatarelu
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA; (S.J.); (A.V.N.); (C.-P.S.)
| | - Geoffrey P. Luke
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA; (S.J.); (A.V.N.); (C.-P.S.)
- Translational Engineering in Cancer Program, Dartmouth Cancer Center, Lebanon, NH 03756, USA
- Correspondence:
| |
Collapse
|
9
|
Hacker L, Wabnitz H, Pifferi A, Pfefer TJ, Pogue BW, Bohndiek SE. Criteria for the design of tissue-mimicking phantoms for the standardization of biophotonic instrumentation. Nat Biomed Eng 2022; 6:541-558. [PMID: 35624150 DOI: 10.1038/s41551-022-00890-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Accepted: 02/07/2022] [Indexed: 01/08/2023]
Abstract
A lack of accepted standards and standardized phantoms suitable for the technical validation of biophotonic instrumentation hinders the reliability and reproducibility of its experimental outputs. In this Perspective, we discuss general criteria for the design of tissue-mimicking biophotonic phantoms, and use these criteria and state-of-the-art developments to critically review the literature on phantom materials and on the fabrication of phantoms. By focusing on representative examples of standardization in diffuse optical imaging and spectroscopy, fluorescence-guided surgery and photoacoustic imaging, we identify unmet needs in the development of phantoms and a set of criteria (leveraging characterization, collaboration, communication and commitment) for the standardization of biophotonic instrumentation.
Collapse
Affiliation(s)
- Lina Hacker
- Department of Physics, University of Cambridge, Cambridge, UK.,Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK
| | - Heidrun Wabnitz
- Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
| | | | | | - Brian W Pogue
- Thayer School of Engineering, Dartmouth, Hanover, NH, USA
| | - Sarah E Bohndiek
- Department of Physics, University of Cambridge, Cambridge, UK. .,Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK.
| |
Collapse
|
10
|
Zhong X, Zhou P, Zhao Y, Liu W, Zhang X. A novel tissue-mimicking phantom for US/CT/MR-guided tumor puncture and thermal ablation. Int J Hyperthermia 2022; 39:557-563. [PMID: 35379066 DOI: 10.1080/02656736.2022.2056249] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
AIM This study aimed to develop a novel tumor-bearing tissue phantom model that can be used for US/CT/MR-guided tumor puncture and thermal ablation. METHODS The phantom model comprised two parts: a normal tissue-mimicking phantom and a tumor-mimicking phantom. A normal tissue phantom was prepared based on a polyacrylamide gel mixed with thermochromic ink. Moreover, a spherical phantom containing contrast agents was constructed and embedded in the tissue phantom to mimic a tumor lesion. US/CT/MR imaging features and thermochromic property of the phantom model were characterized. Finally, the utility of the phantom model for imaging-guided microwave ablation training was examined. RESULTS The tumor phantom containing contrast agents showed hyper-echogenicity, higher CT numbers, and lower T2 signal intensity compared with the normal tissue phantom in US/CT/MR images. Consequently, we could locate the position of the tumor in US/CT/MR imaging and perform an imaging-guided tumor puncture. When the temperature reached the threshold of 60 °C, the phantom exhibited a permanent color change from cream white to magenta. Based on this obvious color change, our phantom model could clearly map the thermal ablation region after thermotherapy. CONCLUSIONS We developed a novel US/CT/MR-imageable tumor-bearing tissue model that can be used for imaging-guided tumor puncture and thermal ablation. Furthermore, it allows visual assessment of the ablation region by analyzing the obvious color change. Overall, this phantom model could be a good training tool in the field of thermal ablation.
Collapse
Affiliation(s)
- Xinyu Zhong
- Department of Ultrasound, The Third Xiangya Hospital, Central South University, Changsha, China
| | - Ping Zhou
- Department of Ultrasound, The Third Xiangya Hospital, Central South University, Changsha, China
| | - Yongfeng Zhao
- Department of Ultrasound, The Third Xiangya Hospital, Central South University, Changsha, China
| | - Wengang Liu
- Department of Ultrasound, The Third Xiangya Hospital, Central South University, Changsha, China
| | - Xinghao Zhang
- Department of Ultrasound, The Third Xiangya Hospital, Central South University, Changsha, China
| |
Collapse
|
11
|
Kim J, Kim M. Focal position control of ultrasonic transducer made of plano-concave form piezoelectric vibrator. ULTRASONICS 2022; 121:106668. [PMID: 35016081 DOI: 10.1016/j.ultras.2021.106668] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 10/01/2021] [Accepted: 12/15/2021] [Indexed: 06/14/2023]
Abstract
The use of therapeutic focused ultrasound requires control of the focal position for different treatment regions. In this study, a piezoelectric ultrasonic transducer of plano-concave form was designed, and the change of the focal position depending on the frequency of the driving signal of the fabricated transducer was experimentally investigated. PVA gel and thermochromic liquid crystal film were used to observe the thermal distribution in the focal region caused by focused ultrasound produced by the transducer. The ability to control the position of the focal region between (62 and 154) % of the geometric focal length of the transducer, depending on the input signal frequency change, was confirmed. The change of acoustic field distribution, which was calculated using the transfer function of the vibration element distributed on the surface of the transducer as the source strength, showed good agreement with the change of temperature distribution experimentally observed.
Collapse
Affiliation(s)
- Jungsoon Kim
- Department of Electrical Engineering, Tongmyong University, Busan, 48520, Republic of Korea
| | - Moojoon Kim
- Department of Physics, Pukyong National University, Busan, 48513, Republic of Korea.
| |
Collapse
|
12
|
Xin Y, Zhang A, Xu LX, Fowlkes JB. Numerical Study of Bubble Cloud and Thermal Lesion Evolution During Acoustic Droplet Vaporization Enhanced HIFU Treatment. J Biomech Eng 2022; 144:1119457. [PMID: 34505142 DOI: 10.1115/1.4052374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Indexed: 11/08/2022]
Abstract
Acoustic droplet vaporization (ADV) has been proven to enhance high intensity focused ultrasound (HIFU) thermal ablation of tumor. It has also been demonstrated that triggering droplets before HIFU exposure could be a potential way to control both the size and the shape of the thermal lesion. In this paper, a numerical model is proposed to predict the thermal lesion created in ADV enhanced HIFU treatment. Bubble oscillation was coupled into a viscoelastic medium in the model to more closely represent real applications in tissues. Several physical processes caused by continuous wave ultrasound and elevated temperature during the HIFU exposure were considered, including rectified diffusion, gas solubility variation with temperature in the medium, and boiling. Four droplet concentrations spanning two orders of magnitude were calculated. The bubble cloud formed from triggering of the droplets by the pulse wave ultrasound, along with the evolution of the shape and location of the bubble cloud and thermal lesion during the following continuous wave exposure was obtained. The increase of bubble void fraction caused by continuous wave exposure was found to be consistent with the experimental observation. With the increase of droplet concentration, the predicted bubble cloud shapes vary from tadpole to triangular and double triangular, while the thermal lesions move toward the transducer. The results show that the assumptions used in this model increased the accuracy of the results. This model may be used for parametrical study of ADV enhanced HIFU treatment and be further used for treatment planning and optimization in the future.
Collapse
Affiliation(s)
- Ying Xin
- School of Biomedical Engineering, Shanghai Jiao Tong University, 400 Med-X Research Institute, 1954 Huashan Road, Shanghai 200030, China
| | - Aili Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, 400 Med-X Research Institute, 1954 Huashan Road, Shanghai 200030, China
| | - Lisa X Xu
- School of Biomedical Engineering, Shanghai Jiao Tong University, 400 Med-X Research Institute, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030, China
| | - J Brian Fowlkes
- Department of Radiology, University of Michigan Health System, 3226C, Medical Sciences Building I, 1301 Catherine Street, Ann Arbor, MI 48109
| |
Collapse
|
13
|
Antoniou A, Damianou C. MR relaxation properties of tissue-mimicking phantoms. ULTRASONICS 2022; 119:106600. [PMID: 34627028 DOI: 10.1016/j.ultras.2021.106600] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/20/2021] [Accepted: 09/21/2021] [Indexed: 06/13/2023]
Abstract
High quality tissue-mimicking phantoms (TMPs) have a critical role in the preclinical testing of emerging modalities for diagnosis and therapy. TMPs capable of accurately mimicking real tissue in Magnetic Resonance guided Focused Ultrasound (MRgFUS) applications should be fabricated with precise T1 and T2 relaxation times. Given the current popularity of the MRgFUS technology, we herein performed a systematic review on the MR relaxation properties of different phantoms types. Polyacrylamide (PAA) and agar based phantoms were proven capable of accurately replicating critical thermal, acoustical, and MR relaxation properties of various body tissues. Although gelatin phantoms were also proven factional in this regard, they lack the capacity to withstand ablation temperatures, and thus, are only recommended for hyperthermia applications. Other gelling agents identified in the literature are Poly-vinyl alcohol (PVA), Polyvinyl Chloride (PVC), silicone, and TX-150/ TX-151; however, their efficacy in thermal studies is yet to be established. PAA gels are favorable in that they offer optical transparency enabling direct visualization of coagulative lesions. On the other hand, agar phantoms have lower preparation costs and were proven very promising for use with the MRgFUS technology, without the toxicity issues related to the preparation and storage of PAA materials. Remarkably, agar turned out to be the prominent modifier of the T2 relaxation time even for phantoms containing other types of gelling agents instead of agar. This review could be useful in manufacturing realistic MRgFUS phantoms while simultaneously indicating an opportunity for further research in the field with a particular focus on the MR behavior of agar-based TMPs.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| |
Collapse
|
14
|
Namen AV, Jandhyala S, Jordan T, Luke GP. Repeated Acoustic Vaporization of Perfluorohexane Nanodroplets for Contrast-Enhanced Ultrasound Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:3497-3506. [PMID: 34191726 PMCID: PMC8667194 DOI: 10.1109/tuffc.2021.3093828] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Superheated perfluorocarbon nanodroplets are emerging ultrasound imaging contrast agents that boast biocompatible components, unique phase-change dynamics, and therapeutic loading capabilities. Upon exposure to a sufficiently high-intensity pulse of acoustic energy, the nanodroplet's perfluorocarbon core undergoes a liquid-to-gas phase change and becomes an echogenic microbubble, providing ultrasound contrast. The controllable activation leads to high-contrast images, while the small size of the nanodroplets promotes longer circulation times and better in vivo stability. One drawback, however, is that the nanodroplets can only be vaporized a single time, limiting their versatility. Recently, we and others have addressed this issue by using a perfluorohexane core, which has a boiling point above body temperature. Thus after vaporization, the microbubbles recondense back into their stable nanodroplet form. Previous work with perfluorohexane nanodroplets relied on optical activation via pulsed laser absorption of an encapsulated dye. This strategy limits the imaging depth and temporal resolution of the method. In this study, we overcome these limitations by demonstrating acoustic droplet vaporization with 1.1-MHz high-intensity focused ultrasound (HIFU). A short-duration, high-amplitude pulse of focused ultrasound provides a sufficiently strong peak negative pressure to initiate vaporization. A custom imaging sequence was developed to enable the synchronization of a HIFU transducer and a linear array imaging transducer. We show a visualization of repeated acoustic activation of perfluorohexane nanodroplets in polyacrylamide tissue-mimicking phantoms. We further demonstrate the detection of hundreds of vaporization events from individual nanodroplets with activation thresholds well below the tissue cavitation limit. Overall, this approach has the potential to result in reliable and repeatable contrast-enhanced ultrasound imaging at clinically relevant depths.
Collapse
|
15
|
Chen J, Nan Z, Zhao Y, Zhang L, Zhu H, Wu D, Zong Y, Lu M, Ilovitsh T, Wan M, Yan K, Feng Y. Enhanced HIFU Theranostics with Dual-Frequency-Ring Focused Ultrasound and Activatable Perfluoropentane-Loaded Polymer Nanoparticles. MICROMACHINES 2021; 12:mi12111324. [PMID: 34832737 PMCID: PMC8621746 DOI: 10.3390/mi12111324] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 10/19/2021] [Accepted: 10/25/2021] [Indexed: 02/06/2023]
Abstract
High-intensity focused ultrasound (HIFU) has been widely used in tumor ablation in clinical settings. Meanwhile, there is great potential to increase the therapeutic efficiency of temporary cavitation due to enhanced thermal effects and combined mechanical effects from nonlinear vibration and collapse of the microbubbles. In this study, dual-frequency (1.1 and 5 MHz) HIFU was used to produce acoustic droplet vaporization (ADV) microbubbles from activatable perfluoropentane-loaded polymer nanoparticles (PFP@Polymer NPs), which increased the therapeutic outcome of the HIFU and helped realize tumor theranostics with ultrasound contrast imaging. Combined with PFP@Polymer NPs, dual-frequency HIFU changed the shape of the damage lesion and reduced the acoustic intensity threshold of thermal damage significantly, from 216.86 to 62.38 W/cm2. It produced a nearly 20 °C temperature increase in half the irradiation time and exhibited a higher tumor inhibition rate (84.5% ± 3.4%) at a low acoustic intensity (1.1 MHz: 23.77 W/cm2; 5 MHz: 0.35 W/cm2) in vitro than the single-frequency HIFU (60.2% ± 11.9%). Moreover, compared with the traditional PFP@BSA NDs, PFP@Polymer NPs showed higher anti-tumor efficacy (81.13% vs. 69.34%; * p < 0.05) and better contrast-enhanced ultrasound (CEUS) imaging ability (gray value of 57.53 vs. 30.67; **** p < 0.0001), probably benefitting from its uniform and stable structure. It showed potential as a highly efficient tumor theranostics approach based on dual-frequency HIFU and activatable PFP@Polymer NPs.
Collapse
Affiliation(s)
- Junjie Chen
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Zhezhu Nan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Yubo Zhao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Lei Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Hongrui Zhu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Daocheng Wu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Yujin Zong
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Mingzhu Lu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Tali Ilovitsh
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv 6997801, Israel;
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Kai Yan
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
- Correspondence: (K.Y.); (Y.F.)
| | - Yi Feng
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
- Correspondence: (K.Y.); (Y.F.)
| |
Collapse
|
16
|
Drakos T, Antoniou A, Evripidou N, Alecou T, Giannakou M, Menikou G, Constantinides G, Damianou C. Ultrasonic Attenuation of an Agar, Silicon Dioxide, and Evaporated Milk Gel Phantom. J Med Ultrasound 2021; 29:239-249. [PMID: 35127403 PMCID: PMC8772477 DOI: 10.4103/jmu.jmu_145_20] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 12/26/2020] [Accepted: 01/07/2021] [Indexed: 11/11/2022] Open
Abstract
Background: It has been demonstrated that agar-based gel phantoms can emulate the acoustic parameters of real tissues and are the most commonly used tissue-mimicking materials for high-intensity focused ultrasound applications. The following study presents ultrasonic attenuation measurements of agar-based phantoms with different concentrations of additives (percent of agar, silicon dioxide and evaporated milk) in an effort of matching the material's acoustic property as close as possible to human tissues. Methods: Nine different agar-based phantoms with various amounts of agar, silicon dioxide, and evaporated milk were prepared. Attenuation measurements of the samples were conducted using the through-transmission immersion techniques. Results: The ultrasonic attenuation coefficient of the agar-based phantoms varied in the range of 0.30–1.49 dB/cm-MHz. The attenuation was found to increase in proportion to the concentration of agar and evaporated milk. Silicon dioxide was found to significantly contribute to the attenuation coefficient up to 4% weight to volume (w/v) concentration. Conclusion: The acoustic attenuation coefficient of agar-based phantoms can be adjusted according to the tissue of interest in the range of animal and human tissues by the proper selection of agar, silicon dioxide, and evaporated milk.
Collapse
Affiliation(s)
| | - Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Nikolas Evripidou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Tereza Alecou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | | | - Georgios Menikou
- Medical Physics Sector, State Health Services Organization, Nicosia General Hospital, Nicosia, Cyprus
| | - Georgios Constantinides
- Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| |
Collapse
|
17
|
Gautam UC, Pydi YS, Selladurai S, Das CJ, Thittai AK, Roy S, Datla NV. A Poly-vinyl Alcohol (PVA)-based phantom and training tool for use in simulated Transrectal Ultrasound (TRUS) guided prostate needle biopsy procedures. Med Eng Phys 2021; 96:46-52. [PMID: 34565552 DOI: 10.1016/j.medengphy.2021.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 08/16/2021] [Accepted: 08/24/2021] [Indexed: 10/20/2022]
Abstract
Trans-rectal ultrasound-guided needle biopsy is a well-established diagnosis technique for prostate cancer. To enhance the needle manoeuvring skills under ultrasound (US) guidance, it is preferable to train medical practitioners in needle biopsy on tissue-mimicking phantoms. This phantom should mimic the morphology as well as mechanical and acoustic properties of the human male pelvic region to provide a surgical experience and feedback. In this study, polyvinyl alcohol (PVA) was used and evaluated for prostate phantom development, that is stiffness tunable, US-compatible and durable phantom material. Three samples, each with 5%, 10%, and 15% concentration of PVA material, were prepared, and their mechanical and shrinkage characteristics were investigated. The anatomy of male pelvic region was used to develop an anatomically correct phantom. Later US-guided needle biopsy was performed on the phantom. The range of elastic moduli of the PVA samples was 2∼146 kPa. Their elastic moduli and volumes were found to remain statistically close from seventh to eighth freeze-thaw cycle (p>0.05). Initial US scans of the phantom resulted in satisfactory B-mode images, with a clear distinction between the prostate and its surrounding organs. This study demonstrated the applicability of PVA hydrogel as a phantom material for training in US-guided needle biopsy.
Collapse
Affiliation(s)
- Umesh C Gautam
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India; Department of Applied Mechanics, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Yeswanth S Pydi
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | | | - Chandan J Das
- Department of Radiology, All India Institute of Medical Sciences, Ansari Nagar, New Delhi 110029, India
| | - Arun K Thittai
- Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai 600036, India
| | - Sitikantha Roy
- Department of Applied Mechanics, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Naresh V Datla
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India.
| |
Collapse
|
18
|
de Andrade MO, Haqshenas SR, Pahk KJ, Saffari N. Modeling the Physics of Bubble Nucleation in Histotripsy. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2871-2883. [PMID: 34260353 DOI: 10.1109/tuffc.2021.3097118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
This work aims to establish a theoretical framework for the modeling of bubble nucleation in histotripsy. A phenomenological version of the classical nucleation theory was parametrized with histotripsy experimental data, fitting a temperature-dependent activity factor that harmonizes theoretical predictions and experimental data for bubble nucleation at both high and low temperatures. Simulations of histotripsy pressure and temperature fields are then used in order to understand spatial and temporal properties of bubble nucleation at varying sonication conditions. This modeling framework offers a thermodynamic understanding on the role of the ultrasound frequency, waveforms, peak focal pressures, and duty cycle on patterns of ultrasound-induced bubble nucleation. It was found that at temperatures lower than 50 °C, nucleation rates are more appreciable at very large negative pressures such as -30 MPa. For focal peak-negative pressures of -15 MPa, characteristic of boiling histotripsy, nucleation rates grow by 20 orders of magnitude in the temperature interval 60 °C-100 °C.
Collapse
|
19
|
Hariri A, Palma-Chavez J, Wear KA, Pfefer TJ, Jokerst JV, Vogt WC. Polyacrylamide hydrogel phantoms for performance evaluation of multispectral photoacoustic imaging systems. PHOTOACOUSTICS 2021; 22:100245. [PMID: 33747787 PMCID: PMC7972966 DOI: 10.1016/j.pacs.2021.100245] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 12/09/2020] [Accepted: 02/12/2021] [Indexed: 05/21/2023]
Abstract
As photoacoustic imaging (PAI) begins to mature and undergo clinical translation, there is a need for well-validated, standardized performance test methods to support device development, quality control, and regulatory evaluation. Despite recent progress, current PAI phantoms may not adequately replicate tissue light and sound transport over the full range of optical wavelengths and acoustic frequencies employed by reported PAI devices. Here we introduce polyacrylamide (PAA) hydrogel as a candidate material for fabricating stable phantoms with well-characterized optical and acoustic properties that are biologically relevant over a broad range of system design parameters. We evaluated suitability of PAA phantoms for conducting image quality assessment of three PAI systems with substantially different operating parameters including two commercial systems and a custom system. Imaging results indicated that appropriately tuned PAA phantoms are useful tools for assessing and comparing PAI system image quality. These phantoms may also facilitate future standardization of performance test methodology.
Collapse
Affiliation(s)
- Ali Hariri
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
| | - Jorge Palma-Chavez
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
| | - Keith A Wear
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| | - T Joshua Pfefer
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| | - Jesse V Jokerst
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
- Department of Radiology, University of California San Diego, La Jolla, CA 92093, USA
- Materials Science and Engineering Program, University of California San Diego, La Jolla, CA 92093, USA
| | - William C Vogt
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| |
Collapse
|
20
|
Drakos T, Giannakou M, Menikou G, Constantinides G, Damianou C. Characterization of a soft tissue-mimicking agar/wood powder material for MRgFUS applications. ULTRASONICS 2021; 113:106357. [PMID: 33548756 DOI: 10.1016/j.ultras.2021.106357] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 12/29/2020] [Accepted: 01/06/2021] [Indexed: 06/12/2023]
Abstract
This study describes the development and characterization of an agar-based soft tissue-mimicking material (TMM) doped with wood powder destined for fabricating MRgFUS applications. The main objective of the following work was to investigate the suitability of wood powder as an inexpensive alternative in replacing other added materials that have been suggested in previous studies for controlling the ultrasonic properties of TMMs. The characterization procedure involved a series of experiments designed to estimate the acoustic (attenuation coefficient, absorption coefficient, propagation speed, and impedance), thermal (conductivity, diffusivity, specific heat capacity), and MR properties (T1 and T2 relaxation times) of the wood-powder doped material. The developed TMM (2% w/v agar and 4% w/v wood powder) as expected demonstrated compatibility with MRI scanner following images artifacts evaluation. The acoustic attenuation coefficient of the proposed material was measured over the frequency range of 1.1-3 MHz and found to be nearly proportional to frequency. The measured attenuation coefficient was 0.48 dB/cm at 1 MHz which was well within the range of soft tissue. Temperatures over 37 °C proved to increase marginally the attenuation coefficient. Following the transient thermoelectric method, the acoustic absorption coefficient was estimated at 0.34 dB/cm-MHz. The estimated propagation speed (1487 m/s) was within the range of soft tissue at room temperature, while it significantly increased with higher temperature. The material possessed an acoustic impedance of 1.58 MRayl which was found to be comparable to the corresponding value of muscle tissue. The thermal conductivity of the material was estimated at 0.51 W/m K. The measured relaxation times T1 (844 ms) and T2 (66 ms) were within the range of values found in the literature for soft tissue. The phantom was tested for its suitability for evaluating MRgFUS thermal protocols. High acoustic energy was applied, and temperature change was recorded using thermocouples and MR thermometry. MR thermal maps were acquired using single-shot Echo Planar Imaging (EPI) gradient echo sequence. The TMM matched adequately the acoustic and thermal properties of human tissues and through a series of experiments, it was proven that wood concentration enhances acoustic absorption. Experiments using MR thermometry demonstrated the usefulness of this phantom to evaluate ultrasonic thermal protocols by monitoring peak temperatures in real-time. Thermal lesions formed above a thermal dose were observed in high-resolution MR images and visually in dissections of the proposed TMM.
Collapse
Affiliation(s)
| | | | - Georgios Menikou
- Medical Physics Sector, State Health Services Organization, Nicosia General Hospital, Nicosia, Cyprus.
| | - Georgios Constantinides
- Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol, Cyprus.
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| |
Collapse
|
21
|
Antoniou A, Evripidou N, Giannakou M, Constantinides G, Damianou C. Acoustical properties of 3D printed thermoplastics. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:2854. [PMID: 33940906 DOI: 10.1121/10.0004772] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 04/03/2021] [Indexed: 06/12/2023]
Abstract
With focused ultrasound (FUS) gaining popularity as a therapeutic modality for brain diseases, the need for skull phantoms that are suitable for evaluating FUS protocols is increasing. In the current study, the acoustical properties of several three-dimensional (3D) printed thermoplastic samples were evaluated to assess their suitability to mimic human skull and bone accurately. Samples were 3D printed using eight commercially available thermoplastic materials. The acoustic properties of the printed samples, including attenuation coefficient, speed of sound, and acoustic impedance, were investigated using transmission-through and pulse-echo techniques. The ultrasonic attenuation, estimated at a frequency of 1.1 MHz, varied from approximately 7 to 32 dB/cm. The frequency dependence of attenuation was described by a power law in the frequency range of 0.2-3.5 MHz, and the exponential index of frequency was found to vary from 1.30 to 2.24. The longitudinal velocity of 2.7 MHz sound waves was in the range of 1700-3050 m/s. The results demonstrate that thermoplastics could potentially be used for the 3D construction of high-quality skull phantoms.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering and Computer Engineering and Informatics, Cyprus University of Technology, 30 Archiepiskopou Kyprianou Street, Limassol, 3036, Cyprus
| | - Nikolas Evripidou
- Department of Electrical Engineering and Computer Engineering and Informatics, Cyprus University of Technology, 30 Archiepiskopou Kyprianou Street, Limassol, 3036, Cyprus
| | - Marinos Giannakou
- MEDSONIC LTD, 35 Christaki Kranou Street, Germasogia, Limassol, 4041, Cyprus
| | - Georgios Constantinides
- Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, 30 Archiepiskopou Kyprianou Street, Limassol, 3036, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering and Computer Engineering and Informatics, Cyprus University of Technology, 30 Archiepiskopou Kyprianou Street, Limassol, 3036, Cyprus
| |
Collapse
|
22
|
Altun B, Demirkan I, Isik EO, Kocaturk O, Unlu MB, Garipcan B. Acoustic impedance measurement of tissue mimicking materials by using scanning acoustic microscopy. ULTRASONICS 2021; 110:106274. [PMID: 33130362 DOI: 10.1016/j.ultras.2020.106274] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 10/02/2020] [Accepted: 10/06/2020] [Indexed: 06/11/2023]
Abstract
Tissue-mimicking materials (TMMs) play a key role in the quality assurance of ultrasound diagnostic equipment and should have acoustic properties similar to human tissues. We propose a method to quantify the acoustic properties of TMM samples through the use of an 80 MHz Scanning Acoustic Microscopy (SAM), which provides micrometer resolution and fast data recording. We produced breast TMM samples in varying compositions that resulted in acoustic impedance values in the range of 1.373 ± 0.031 and 1.707 ± 0.036 MRayl. Additionally, liver TMM and blood mimicking fluid (BMF) samples were prepared that had acoustic impedance values of 1.693 ± 0.085 MRayl and 1.624 ± 0.006 MRayl, respectively. The characterization of the TMMs by SAM may provide reproducible and uniform acoustic reference data for tissue substitutes in a single-run microscopy experiment.
Collapse
Affiliation(s)
- Burak Altun
- Bogazici University, Institute of Biomedical Engineering, Istanbul 34684, Turkey
| | - Irem Demirkan
- Bogazici University, Department of Physics, Istanbul 34342, Turkey
| | - Esin Ozturk Isik
- Bogazici University, Institute of Biomedical Engineering, Istanbul 34684, Turkey
| | - Ozgur Kocaturk
- Bogazici University, Institute of Biomedical Engineering, Istanbul 34684, Turkey
| | - Mehmet Burcin Unlu
- Bogazici University, Department of Physics, Istanbul 34342, Turkey; Global Station for Quantum Medical Science and Engineering, Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo 060- 8648, Japan
| | - Bora Garipcan
- Bogazici University, Institute of Biomedical Engineering, Istanbul 34684, Turkey.
| |
Collapse
|
23
|
Charkhabi S, Jackson KJ, Beierle AM, Carr AR, Zellner EM, Reuel NF. Monitoring Wound Health through Bandages with Passive LC Resonant Sensors. ACS Sens 2021; 6:111-122. [PMID: 33381967 DOI: 10.1021/acssensors.0c01912] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
This paper details a passive, inductor-capacitor (LC) resonant sensor embedded in a commercial dressing for low-cost, contact-free monitoring of a wound; this would enable tracking of the healing process while keeping the site closed and sterile. Spiral LC resonators were fabricated from flexible, copper-coated polyimide and interrogated using external reader antennas connected to a two-port vector network analyzer; the forward transmission scattering parameter (S21) magnitude was collected, and the resonant frequency (MHz) and the peak-to-peak amplitude of the resonant feature were identified. These increase during the healing process as the permittivity and conductivity of the tissue change. The sensor was first tested on gelatin-based tissue-mimicking phantoms that simulate layers of muscle, blood, fat, and skin at varying phases of wound healing. Finite element modeling was also used to verify the empirical results based on the expected variations in dielectric properties of the tissue. The performance of the resonant sensors for in vivo applications was investigated by conducting animal studies using canine patients that presented with a natural wound as well as a controlled cohort of rat models with surgically administered wounds. Finally, transfer functions are presented that relate the resonant frequency to wound size using an exponential model (R2 = 0.58-0.96). The next steps in sensor design and fabrication as well as the reading platform to achieve the goal of a universal calibration curve are then discussed.
Collapse
Affiliation(s)
- Sadaf Charkhabi
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Kyle J. Jackson
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Andee M. Beierle
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Adam R. Carr
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Eric M. Zellner
- Department of Veterinary Clinical Sciences, Iowa State University, Ames, Iowa 50011, United States
| | - Nigel F. Reuel
- Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011, United States
| |
Collapse
|
24
|
Pahk KJ, Lee S, Gélat P, de Andrade MO, Saffari N. The interaction of shockwaves with a vapour bubble in boiling histotripsy: The shock scattering effect. ULTRASONICS SONOCHEMISTRY 2021; 70:105312. [PMID: 32866882 PMCID: PMC7786583 DOI: 10.1016/j.ultsonch.2020.105312] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 06/24/2020] [Accepted: 08/17/2020] [Indexed: 05/13/2023]
Abstract
Boiling histotripsy is a High Intensity Focused Ultrasound (HIFU) technique which uses a number of short pulses with high acoustic pressures at the HIFU focus to induce mechanical tissue fractionation. In boiling histotripsy, two different types of acoustic cavitation contribute towards mechanical tissue destruction: a boiling vapour bubble and cavitation clouds. An understanding of the mechanisms underpinning these phenomena and their dynamics is therefore paramount to predicting and controlling the overall size of a lesion produced for a given boiling histotripsy exposure condition. A number of studies have shown the effects of shockwave heating in generating a boiling bubble at the HIFU focus and have studied its dynamics under boiling histotripsy insonation. However, not much is known about the subsequent production of cavitation clouds that form between the HIFU transducer and the boiling bubble. The main objective of the present study is to examine what causes this bubble cluster formation after the generation of a boiling vapour bubble. A numerical simulation of 2D nonlinear wave propagation with the presence of a bubble at the focus of a HIFU field was performed using the k-Wave MATLAB toolbox for time domain ultrasound simulations, which numerically solves the generalised Westervelt equation. The numerical results clearly demonstrate the appearance of the constructive interference of a backscattered shockwave by a bubble with incoming incident shockwaves. This interaction (i.e., the reflected and inverted peak positive phase from the bubble with the incoming incident rarefactional phase) can eventually induce a greater peak negative pressure field compared to that without the bubble at the HIFU focus. In addition, the backscattered peak negative pressure magnitude gradually increased from 17.4 MPa to 31.6 MPa when increasing the bubble size from 0.2 mm to 1.5 mm. The latter value is above the intrinsic cavitation threshold of -28 MPa in soft tissue. Our results suggest that the formation of a cavitation cloud in boiling histotripsy is a threshold effect which primarily depends (a) the size and location of a boiling bubble, and (b) the sum of the incident field and that scattered by a bubble.
Collapse
Affiliation(s)
- Ki Joo Pahk
- Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea.
| | - Sunho Lee
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Pierre Gélat
- Department of Mechanical Engineering, University College London, London WC1E 7JE, UK
| | | | - Nader Saffari
- Department of Mechanical Engineering, University College London, London WC1E 7JE, UK
| |
Collapse
|
25
|
Boppudi ST, Belal S, Guntur SR. Preparation and characterization of a novel sprayable hydrogel for skin preparation to record ECG and other biopotentials. Biomed Eng Lett 2020; 10:533-546. [PMID: 33194246 DOI: 10.1007/s13534-020-00164-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Revised: 06/30/2020] [Accepted: 07/20/2020] [Indexed: 10/23/2022] Open
Abstract
Wet electrodes are widely used to perform biopotential measurements from the body, such as electroencephalogram, electrocardiogram, and electromyogram. These electrodes have certain disadvantages, including bacterial growth, irritation in long-term recordings, infection to patients' skin caused by skin preparation techniques, and unpleasant feeling caused after their removal. Thus, a sprayable hydrogel (SH) was designed to avoid these problems. Five electrode configurations, namely, Zipprep™, wet Ag/AgCl, wipes, dry Ag/AgCl, and SH, were tested using an impedance analyzer. Measurements were obtained by placing each of the electrode systems on the forearm of five subjects, which comprised one Caucasian, two Indians, one Syrian, and one Cypriot aging between 23 and 60 years for 10 min. Impedance versus time and reactance versus resistance performance plots were compared and assessed. The performance of the SH sprayed under dry electrodes had lower impedance values compared with those of the dry Ag/AgCl and wipes. As a result, the SH electrode configuration can be used as an electrode set-up for acquiring and recording various physiological signals.
Collapse
Affiliation(s)
- Sunil Tej Boppudi
- Department of Biomedical Engineering, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur, 522213 India.,Department of Electronics and Communications Engineering, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur, 522213 India
| | - Suliman Belal
- School of Biological Sciences, Division of Neuroscience and Experimental Psychology, Manchester University, Zochonis Building, Brunswick Street, Manchester, M13 9PT UK
| | - Sitaramanjaneya Reddy Guntur
- Department of Biomedical Engineering, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur, 522213 India.,Department of Electronics and Communications Engineering, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur, 522213 India
| |
Collapse
|
26
|
Ambrogio S, Baêsso RDM, Gomis A, Rivens I, Haar GT, Zeqiri B, Ramnarine KV, Fedele F, Miloro P. A Polyvinyl Alcohol-Based Thermochromic Material for Ultrasound Therapy Phantoms. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3135-3144. [PMID: 32873445 DOI: 10.1016/j.ultrasmedbio.2020.07.032] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 07/27/2020] [Accepted: 07/31/2020] [Indexed: 06/11/2023]
Abstract
Temperature estimation is a fundamental step in assessment of the efficacy of thermal therapy. A thermochromic material sensitive within the temperature range 52.5°C-75°C has been developed. The material is based on polyvinyl alcohol cryogel with the addition of a commercial thermochromic ink. It is simple to manufacture, low cost, non-toxic and versatile. The thermal response of the material was evaluated using multiple methods, including immersion in a temperature-controlled water bath, a temperature-controlled heated needle and high-intensity focused ultrasound (HIFU) sonication. Changes in colour were evaluated using both RGB (red, green, blue) maps and pixel intensities. Acoustic and thermal properties of the material were measured. Thermo-acoustic simulations were run with an open-source software, and results were compared with the HIFU experiments, showing good agreement. The material has good potential for the development of ultrasound therapy phantoms.
Collapse
Affiliation(s)
- Simone Ambrogio
- Medical Physics Department, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom; Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington, United Kingdom.
| | - Raphaela de Melo Baêsso
- Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington, United Kingdom
| | - Alberto Gomis
- Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington, United Kingdom; Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Ian Rivens
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Gail Ter Haar
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Bajram Zeqiri
- Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington, United Kingdom
| | - Kumar V Ramnarine
- Medical Physics Department, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Fiammetta Fedele
- Medical Physics Department, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Piero Miloro
- Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington, United Kingdom
| |
Collapse
|
27
|
Guntur SR, Choi MJ. Temperature Dependence of Tissue Thermal Parameters Should Be Considered in the Thermal Lesion Prediction in High-Intensity Focused Ultrasound Surgery. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1001-1014. [PMID: 31983483 DOI: 10.1016/j.ultrasmedbio.2019.10.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2019] [Revised: 10/21/2019] [Accepted: 10/26/2019] [Indexed: 06/10/2023]
Abstract
This study considers the temperature-dependent thermal parameters (specific heat capacity, thermal diffusivity and thermal conductivity) used when predicting the temperature rise of tissue exposed to high-intensity focused ultrasound (HIFU). Numerical analysis was performed using the Khokhlov-Zabolotskaya-Kuznetsov equation coupled with a bioheat transfer function. The thermal parameters were set as the functions of temperature using experimental data. The results revealed that, for liver tissue exposed to HIFU with a focal intensity of 3000 W/cm2 for 10 s, the predicted focal temperature rise was 23% lower and the thermal lesion area 41% smaller than those predicted without considering the temperature dependence. The prediction was validated by experimental observations on thermal lesions visualized in a tissue-mimicking phantom. The present results suggest that temperature-dependent thermal parameters should be considered in the prediction of HIFU-induced temperature rise to avoid lowering ultrasonic output settings for HIFU surgery. The aim of the present study was to investigate how significantly the temperature dependence of the thermal parameters affects the thermal dose imposed on the tissue by a typical clinical HIFU device. A numerical simulation was performed using a thermo-acoustic algorithm coupling the non-linear Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation (Meaney et al. 1998; Filonenko and Khokhlova 2001) and a bio-heat transfer (BHT) equation (Pennes 1948). Thermal parameters of liver tissue were modeled in the present study as functions of temperature and were incorporated into the BHT equation to compensate for the variations in thermal parameters with temperature. Experimental validation was achieved by comparing the predictions with the thermal lesions formed in the tissue-mimicking phantoms.
Collapse
Affiliation(s)
- Sitaramanjaneya Reddy Guntur
- Department of Biomedical Engineering, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur, India
| | - Min Joo Choi
- Department of Medicine, School of Medicine, Jeju National University, Jeju, Republic of Korea.
| |
Collapse
|
28
|
Eranki A, Mikhail AS, Negussie AH, Katti PS, Wood BJ, Partanen A. Tissue-mimicking thermochromic phantom for characterization of HIFU devices and applications. Int J Hyperthermia 2019; 36:518-529. [PMID: 31046513 DOI: 10.1080/02656736.2019.1605458] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
Abstract
PURPOSE Tissue-mimicking phantoms (TMPs) are synthetic materials designed to replicate properties of biological tissues. There is a need to quantify temperature changes following ultrasound or magnetic resonance imaging-guided high intensity focused ultrasound (MR-HIFU). This work describes development, characterization and evaluation of tissue-mimicking thermochromic phantom (TMTCP) for direct visualization and quantification of HIFU heating. The objectives were to (1) develop an MR-imageable, HIFU-compatible TMTCP that reports absolute temperatures, (2) characterize TMTCP physical properties and (3) examine TMTCP color change after HIFU. METHODS AND MATERIALS A TMTCP was prepared to contain thermochromic ink, silicon dioxide and bovine serum albumin (BSA) and its properties were quantified. A clinical MRI-guided and a preclinical US-guided HIFU system were used to perform sonications in TMTCP. MRI thermometry was performed during HIFU, followed by T2-weighted MRI post-HIFU. Locations of color and signal intensity change were compared to the sonication plan and to MRI temperature maps. RESULTS TMTCP properties were comparable to those in human soft tissues. Upon heating, the TMTCP exhibited an incremental but permanent color change for temperatures between 45 and 70 °C. For HIFU sonications the TMTCP revealed spatially sharp regions of color change at the target locations, correlating with MRI thermometry and hypointense regions on T2-weighted MRI. TMTCP-based assessment of various HIFU applications was also demonstrated. CONCLUSIONS We developed a novel MR-imageable and HIFU-compatible TMTCP to characterize HIFU heating without MRI or thermocouples. The HIFU-optimized TMTCP reports absolute temperatures and ablation zone geometry with high spatial resolution. Consequently, the TMTCP can be used to evaluate HIFU heating and may provide an in vitro tool for peak temperature assessment, and reduce preclinical in vivo requirements for clinical translation.
Collapse
Affiliation(s)
- Avinash Eranki
- a Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA.,b Sheikh Zayed Institute for Pediatric Surgical Innovation , Children's National Medical Center , Washington , DC , USA
| | - Andrew S Mikhail
- a Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA
| | - Ayele H Negussie
- a Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA
| | - Prateek S Katti
- a Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA.,c Institute of Biomedical Engineering , University of Oxford , Oxford , UK
| | - Bradford J Wood
- a Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA
| | - Ari Partanen
- a Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA
| |
Collapse
|
29
|
Cheng CA, Chen W, Zhang L, Wu HH, Zink JI. A Responsive Mesoporous Silica Nanoparticle Platform for Magnetic Resonance Imaging-Guided High-Intensity Focused Ultrasound-Stimulated Cargo Delivery with Controllable Location, Time, and Dose. J Am Chem Soc 2019; 141:17670-17684. [PMID: 31604010 DOI: 10.1021/jacs.9b07591] [Citation(s) in RCA: 57] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Magnetic resonance imaging (MRI) is an essential modality for clinical diagnosis, and MRI-guided high-intensity focused ultrasound (MRgHIFU) is a powerful technology for targeted therapy. Clinical applications of MRgHIFU primarily utilize hyperthermia and ablation to treat cancerous tissue, but for drug delivery applications thermal damage is undesirable. A biofriendly MRgHIFU-responsive mesoporous silica nanoparticle (MSN) platform that is stimulated within a physiological safe temperature range has been developed, reducing the possibility of thermal damage to the surrounding healthy tissues. Biocompatible polyethylene glycol (PEG) was employed to cap the pores of MSNs, and the release of cargo molecules by HIFU occurs without substantial temperature increase (∼4 °C). To visualize by MRI and measure the stimulated delivery in situ, a U.S. Food and Drug Administration (FDA)-approved gadolinium-based contrast agent, gadopentetate dimeglumine (Gd(DTPA)2-), was used as the imageable cargo. Taking advantage of the three-dimensional (3-D) imaging and targeting capabilities of MRgHIFU, the release of Gd(DTPA)2- stimulated by HIFU was pinpointed at the HIFU focal point in 3-D space in a tissue-mimicking gel phantom. The amount of Gd(DTPA)2- released was controlled by HIFU stimulation times and power levels. A positive correlation between the amount of Gd(DTPA)2- released and T1 was found. The MRgHIFU-stimulated cargo release was further imaged in a sample of ex vivo animal tissue. With this technology, the biodistribution of the nanocarriers can be tracked and the MRgHIFU-stimulated cargo release can be pinpointed, opening up an opportunity for future image-guided theranostic applications.
Collapse
Affiliation(s)
- Chi-An Cheng
- Department of Bioengineering , University of California Los Angeles , Los Angeles , California 90095 , United States.,California NanoSystems Institute , University of California Los Angeles , Los Angeles 90095 , California , United States
| | - Wei Chen
- Department of Chemistry & Biochemistry , University of California Los Angeles , Los Angeles , California 90095 , United States.,California NanoSystems Institute , University of California Los Angeles , Los Angeles 90095 , California , United States
| | - Le Zhang
- Department of Radiological Sciences, David Geffen School of Medicine , University of California Los Angeles , Los Angeles , California 90095 , United States
| | - Holden H Wu
- Department of Bioengineering , University of California Los Angeles , Los Angeles , California 90095 , United States.,Department of Radiological Sciences, David Geffen School of Medicine , University of California Los Angeles , Los Angeles , California 90095 , United States
| | - Jeffrey I Zink
- Department of Chemistry & Biochemistry , University of California Los Angeles , Los Angeles , California 90095 , United States.,California NanoSystems Institute , University of California Los Angeles , Los Angeles 90095 , California , United States
| |
Collapse
|
30
|
Kinoshita T, Effat A, Gregor A, Inage T, Ishiwata T, Motooka Y, Ujiie H, Wilson BC, Zheng G, Weersink R, Asamura H, Yasufuku K. A Novel Laser Fiberscope for Simultaneous Imaging and Phototherapy of Peripheral Lung Cancer. Chest 2019; 156:571-578. [DOI: 10.1016/j.chest.2019.04.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 03/02/2019] [Accepted: 04/02/2019] [Indexed: 11/17/2022] Open
|
31
|
Cho SB, Ahn KJ, Oh D, Kim H, Yoo KH. Sequential delivery of long-pulsed 755-nm alexandrite laser and long-pulsed 1,064-nm neodymium:yttrium-aluminum-garnet laser treatment for pigmented disorders. Skin Res Technol 2019; 25:683-692. [PMID: 31056804 DOI: 10.1111/srt.12704] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2019] [Revised: 02/17/2019] [Accepted: 04/14/2019] [Indexed: 11/27/2022]
Abstract
BACKGROUND Long-pulsed (LP) lasers at pulse durations of 1-300 ms have been used to destroy nests of nevi cells by selectively targeting pigment chromophores. OBJECTIVE To evaluate dual-wavelength LP laser-induced tissue reactions. METHODS The patterns of LP 755-nm alexandrite (Alex) and/or 1064-nm neodymium (Nd):yttrium-aluminum-garnet (YAG) laser-induced tissue reactions were macroscopically evaluated using a tattoo-embedded phantom. Additionally, a pilot in vivo human study was performed for common acquired melanocytic nevus, of which dermoscopic images and high-speed cinematographs were obtained. RESULTS Combinations of Nd:YAG and Alex laser treatments at interpulse intervals of 10 or 20 ms generated round to oval zones of photothermal and photoacoustic injury in two distinctive areas containing disintegrated tattoo particles. Treatment at interpulse intervals of 10 or 20 ms between Alex and Nd:YAG pulses elicited lesser degrees of thermal damage to surrounding tissues, compared to treatment at 100 or 200 ms. Immediately after combined LP laser treatment of human nevus lesions in vivo, Nd:YAG-Alex treatment at a 20-ms interpulse interval exhibited more remarkable crusting and erosive appearances than Alex-Nd:YAG treatment. CONCLUSION For treating pigmented disorders, sequential delivery of LP Nd:YAG and Alex pulses at short interpulse intervals of 10-20 ms can effectively destroy nests of pigment chromophores.
Collapse
Affiliation(s)
- Sung Bin Cho
- Department of Dermatology and Cutaneous Biology Research Center, International St. Mary's Hospital, Catholic Kwandong University College of Medicine, Incheon, Korea.,Yonsei Seran Dermatology and Laser Clinic, Seoul, Korea
| | - Keun Jae Ahn
- Department of Science Education, Jeju National University, Jeju, Korea
| | - Doojin Oh
- Cheongdam Suan Dermatology Clinic, Seoul, Korea
| | - Heesu Kim
- Department of Dermatology and Cutaneous Biology Research Center, International St. Mary's Hospital, Catholic Kwandong University College of Medicine, Incheon, Korea
| | - Kwang Ho Yoo
- Department of Dermatology and Cutaneous Biology Research Center, International St. Mary's Hospital, Catholic Kwandong University College of Medicine, Incheon, Korea
| |
Collapse
|
32
|
Pahk KJ, de Andrade MO, Gélat P, Kim H, Saffari N. Mechanical damage induced by the appearance of rectified bubble growth in a viscoelastic medium during boiling histotripsy exposure. ULTRASONICS SONOCHEMISTRY 2019; 53:164-177. [PMID: 30686603 DOI: 10.1016/j.ultsonch.2019.01.001] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 12/23/2018] [Accepted: 01/02/2019] [Indexed: 05/13/2023]
Abstract
In boiling histotripsy, the presence of a boiling vapour bubble and understanding of its dynamic behaviour are crucially important for the initiation of the tissue fractionation process and for the control of the size of a lesion produced. Whilst many in vivo studies have shown the feasibility of using boiling histotripsy in mechanical fractionation of solid tumours, not much is known about the evolution of a boiling vapour bubble in soft tissue induced by boiling histotripsy. The main objective of this present study is therefore to investigate the formation and dynamic behaviour of a boiling vapour bubble which occurs under boiling histotripsy insonation. Numerical and experimental studies on the bubble dynamics induced in optically transparent tissue-mimicking gel phantoms exposed to the field of a 2.0 MHz High Intensity Focused Ultrasound (HIFU) transducer were performed with a high speed camera. The Gilmore-Zener bubble model coupled with the Khokhlov-Zabolotskaya-Kuznetsov and the Bio-heat Transfer equations was used to simulate bubble dynamics driven by boiling histotripsy waveforms (nonlinear-shocked wave excitation) in a viscoelastic medium as functions of surrounding temperature and of tissue elasticity variations. In vivo animal experiments were also conducted to examine cellular structures around a freshly created lesion in the liver resulting from boiling histotripsy. To the best of our knowledge, this is the first study reporting the numerical and experimental evidence of the appearance of rectified bubble growth in a viscoelastic medium. Accounting for tissue phantom elasticity adds a mechanical constraint on vapour bubble growth, which improves the agreement between the simulation and the experimental results. In addition the numerical calculations showed that the asymmetry in a shockwave and water vapour transport can result in rectified bubble growth which could be responsible for HIFU-induced tissue decellularisation. Strain on liver tissue induced by this radial motion can damage liver tissue while preserving blood vessels.
Collapse
Affiliation(s)
- Ki Joo Pahk
- Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea.
| | | | - Pierre Gélat
- Department of Mechanical Engineering, University College Londo, London WC1E 7JE, UK.
| | - Hyungmin Kim
- Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea.
| | - Nader Saffari
- Department of Mechanical Engineering, University College Londo, London WC1E 7JE, UK.
| |
Collapse
|
33
|
Pahk KJ, Gélat P, Kim H, Saffari N. Bubble dynamics in boiling histotripsy. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:2673-2696. [PMID: 30228043 DOI: 10.1016/j.ultrasmedbio.2018.07.025] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Revised: 07/13/2018] [Accepted: 07/24/2018] [Indexed: 05/24/2023]
Abstract
Boiling histotripsy is a non-invasive, cavitation-based ultrasonic technique which uses a number of millisecond pulses to mechanically fractionate tissue. Though a number of studies have demonstrated the efficacy of boiling histotripsy for fractionation of solid tumours, treatment monitoring by cavitation measurement is not well studied because of the limited understanding of the dynamics of bubbles induced by boiling histotripsy. The main objectives of this work are to (a) extract qualitative and quantitative features of bubbles excited by shockwaves and (b) distinguish between the different types of cavitation activity for either a thermally or a mechanically induced lesion in the liver. A numerical bubble model based on the Gilmore equation accounting for heat and mass transfer (gas and water vapour) was developed to investigate the dynamics of a single bubble in tissue exposed to different High Intensity Focused Ultrasound fields as a function of temperature variation in the fluid. Furthermore, ex vivo liver experiments were performed with a passive cavitation detection system to obtain acoustic emissions. The numerical simulations showed that the asymmetry in a shockwave and water vapour transport are the key parameters which lead the bubble to undergo rectified growth at a boiling temperature of 100°C. The onset of rectified radial bubble motion manifested itself as (a) an increase in the radiated pressure and (b) the sudden appearance of higher order multiple harmonics in the corresponding spectrogram. Examining the frequency spectra produced by the thermal ablation and the boiling histotripsy exposures, it was observed that higher order multiple harmonics as well as higher levels of broadband emissions occurred during the boiling histotripsy insonation. These unique features in the emitted acoustic signals were consistent with the experimental measurements. These features can, therefore, be used to monitor (a) the different types of acoustic cavitation activity for either a thermal ablation or a mechanical fractionation process and (b) the onset of the formation of a boiling bubble at the focus in the course of HIFU exposure.
Collapse
Affiliation(s)
- Ki Joo Pahk
- Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Pierre Gélat
- Department of Mechanical Engineering, University College London, London, WC1E 7JE, UK
| | - Hyungmin Kim
- Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Nader Saffari
- Department of Mechanical Engineering, University College London, London, WC1E 7JE, UK.
| |
Collapse
|
34
|
McLaughlan JR. Controllable Nucleation of Cavitation from Plasmonic Gold Nanoparticles for Enhancing High Intensity Focused Ultrasound Applications. J Vis Exp 2018. [PMID: 30346394 PMCID: PMC6235418 DOI: 10.3791/58045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
In this study, plasmonic gold nanoparticles were simultaneously exposed to pulsed near-infrared laser light and high intensity focused ultrasound (HIFU) for the controllable nucleation of cavitation in tissue-mimicking gel phantoms. This in vitro protocol was developed to demonstrate the feasibility of this approach, for both enhancement of imaging and therapeutic applications for cancer. The same apparatus can be used for both imaging and therapeutic applications by varying the exposure duration of the HIFU system. For short duration exposures (10 µs), broadband acoustic emissions were generated through the controlled nucleation of inertial cavitation around the gold nanoparticles. These emissions provide direct localization of nanoparticles. For future applications, these particles may be functionalized with molecular-targeting antibodies (e.g. anti-HER2 for breast cancer) and can provide precise localization of cancerous regions, complementing routine diagnostic ultrasound imaging. For continuous wave (CW) exposures, the cavitation activity was used to increase the localized heating from the HIFU exposures resulting in larger thermal damage in the gel phantoms. The acoustic emissions generated from inertial cavitation activity during these CW exposures was monitored using a passive cavitation detection (PCD) system to provide feedback of cavitation activity. Increased localized heating was only achieved through the unique combination of nanoparticles, laser light and HIFU. Further validation of this technique in pre-clinical models of cancer is necessary.
Collapse
Affiliation(s)
- James R McLaughlan
- School of Electronic and Electrical Engineering, University of Leeds; Leeds Institute of Cancer and Pathology, University of Leeds;
| |
Collapse
|
35
|
Kim YT, Ma D, Sim JK, Kim SH. Simultaneous Evaluation of Thermal and Non-Thermal Effects of High-Intensity Focused Ultrasound on a Tissue-Mimicking Phantom. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1799-1809. [PMID: 29759425 DOI: 10.1016/j.ultrasmedbio.2018.03.024] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Revised: 02/07/2018] [Accepted: 03/27/2018] [Indexed: 06/08/2023]
Abstract
Physiologically relevant phantoms with high reliability are essential for extending the therapeutic applications of high-intensity therapeutic ultrasound. Here we describe a tissue-mimicking phantom capable of quantifying temperature changes and observing non-thermal phenomena by high-intensity therapeutic ultrasound. Using polydiacetylene liposomes, we fabricated agar-based polydiacetylene hydrogel phantoms (PHPs) that not only respond to temperature, but also have acoustic properties similar to those of human liver tissue. The color of PHPs changed from blue to red depending on the temperature in the range 40°C-70°C, where the red/blue ratio of PHP had a good linearity of 99.06% for the temperature changes. Furthermore, repeated high-intensity focused ultrasound led to histotripsy on the PHP with liquefied and damaged areas measuring 0.7 and 4.0 cm2, respectively, at the signal generator amplitude setting voltage of 80 mV. Our results indicate not only the usability of the thermochromic phantom, but also its potential for evaluating non-thermal phenomena in various high-intensity focused ultrasound therapies.
Collapse
Affiliation(s)
- Yong Tae Kim
- Center for Medical Convergence Metrology, Korea Research Institute of Standards and Science, Daejeon, Republic of Korea; Department of Medical Physics, Korea University of Science and Technology, Daejeon, Republic of Korea
| | - Donghee Ma
- Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, Republic of Korea
| | - Jai Kyoung Sim
- Center for Medical Convergence Metrology, Korea Research Institute of Standards and Science, Daejeon, Republic of Korea
| | - Se-Hwa Kim
- Department of Medical Physics, Korea University of Science and Technology, Daejeon, Republic of Korea; Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, Republic of Korea.
| |
Collapse
|
36
|
Bakaric M, Martin E, S Georgiou P, T Cox B, Payne H, E Treeby B. Experimental study of beam distortion due to fiducial markers during salvage HIFU in the prostate. J Ther Ultrasound 2018; 6:1. [PMID: 29588854 PMCID: PMC5863876 DOI: 10.1186/s40349-018-0109-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Accepted: 03/13/2018] [Indexed: 11/10/2022] Open
Abstract
Background Prostate cancer is frequently treated using external beam radiation therapy (EBRT). Prior to therapy, the prostate is commonly implanted with a small number of permanent fiducial markers used to monitor the position of the prostate during therapy. In the case of local cancer recurrence, high-intensity focused ultrasound (HIFU) provides a non-invasive salvage treatment option. However, the impact of the fiducial markers on HIFU treatment has not been thoroughly studied to date. The objective of this study was to experimentally investigate the effect of a single EBRT fiducial marker on the efficacy of HIFU treatment delivery using a tissue-mimicking material (TMM). Methods A TMM with the acoustic properties of the prostate was developed based on a polyacrylamide hydrogel containing bovine serum albumin. Each phantom was implanted with a cylindrical fiducial marker and then sonicated using a 3.3 MHz focused bowl HIFU transducer. Two sets of experiments were performed. In the first, a single lesion was created at different positions along either the anteroposterior or left-right axes relative to the marker. In the second, a larger ablation volume was created by raster scanning. The size and position of the ablated volume were assessed using a millimetre grid overlaid on the phantom. Results The impact of the marker on the position and size of the HIFU lesion was significant when the transducer focus was positioned within 7 mm anteriorly, 18 mm posteriorly or within 3 mm laterally of the marker. Beyond this, the generated lesion was not affected. When the focus was anterior to the marker, the lesion increased in size due to reflections. When the focus was posterior, the lesion decreased in size or was not present due to shadowing. Conclusions The presence of an EBRT fiducial marker may result in an undertreated region beyond the marker due to reduced energy arriving at the focus, and an overtreated region in front of the marker due to reflections. Depending on the position of the targeted regions and the distribution of the markers, both effects may be undesirable and reduce treatment efficacy. Further work is necessary to investigate whether these results indicate the necessity to reconsider patient selection and treatment planning for prostate salvage HIFU after failed EBRT.
Collapse
Affiliation(s)
- Marina Bakaric
- 1Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT UK
| | - Eleanor Martin
- 1Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT UK
| | - Panayiotis S Georgiou
- 1Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT UK
| | - Benjamin T Cox
- 1Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT UK
| | - Heather Payne
- 1Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT UK.,2Department of Oncology, University College London Hospitals, 235 Euston Road, London, NW1 2BU UK
| | - Bradley E Treeby
- 1Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT UK
| |
Collapse
|
37
|
McLaughlan JR, Cowell DMJ, Freear S. Gold nanoparticle nucleated cavitation for enhanced high intensity focused ultrasound therapy. Phys Med Biol 2017; 63:015004. [PMID: 29098986 DOI: 10.1088/1361-6560/aa97e9] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
High intensity focused ultrasound (HIFU) or focused ultrasound surgery is a non-invasive technique for the treatment of cancerous tissue, which is limited by difficulties in getting real-time feedback on treatment progress and long treatment durations. The formation and activity of acoustic cavitation, specifically inertial cavitation, during HIFU exposures has been demonstrated to enhance heating rates. However, without the introduction of external nuclei its formation an activity can be unpredictable, and potentially counter-productive. In this study, a combination of pulse laser illumination (839 nm), HIFU exposures (3.3 MHz) and plasmonic gold nanorods (AuNR) was demonstrated as a new approach for the guidance and enhancement of HIFU treatments. For imaging, short duration HIFU pulses (10 μs) demonstrated broadband acoustic emissions from AuNR nucleated cavitation with a signal-to-noise ranging from 5-35 dB for peak negative pressures between 1.19-3.19 ± 0.01 MPa. In the absence of either AuNR or laser illumination these emissions were either not present or lower in magnitude (e.g. 5 dB for 3.19 MPa). Continuous wave (CW) HIFU exposures for 15 s, were then used to generate thermal lesions for peak negative pressures from 0.2-2.71 ± 0.01 MPa at a fluence of 3.4 mJ [Formula: see text]. Inertial cavitation dose (ICD) was monitored during all CW exposures, where exposures combined with both laser illumination and AuNRs resulted in the highest level of detectable emissions. This parameter was integrated over the entire exposure to give a metric to compare with measured thermal lesion area, where it was found that a minimum total ICD of [Formula: see text] a.u. was correlated with the formation of thermal lesions in gel phantoms. Furthermore, lesion area (mm2) was increased for equivalent exposures without either AuNRs or laser illumination. Once combined with cancer targeting AuNRs this approach could allow for the future theranostic use of HIFU, such as providing the ability to identify and treat small multi-focal cancerous regions with minimal damage to surrounding healthy tissue.
Collapse
Affiliation(s)
- J R McLaughlan
- School of Electronic and Electrical Engineering, University of Leeds, Leeds, LS2 9JT, United Kingdom. Leeds Institute of Cancer and Pathology, University of Leeds, Leeds, LS9 7TF, United Kingdom
| | | | | |
Collapse
|
38
|
Liu T, Zhang N, Wang Z, Wu M, Chen Y, Ma M, Chen H, Shi J. Endogenous Catalytic Generation of O 2 Bubbles for In Situ Ultrasound-Guided High Intensity Focused Ultrasound Ablation. ACS NANO 2017; 11:9093-9102. [PMID: 28796487 DOI: 10.1021/acsnano.7b03772] [Citation(s) in RCA: 103] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
High intensity focused ultrasound (HIFU) surgery generally suffers from poor precision and low efficiency in clinical application, especially for cancer therapy. Herein, a multiscale hybrid catalytic nanoreactor (catalase@MONs, abbreviated as C@M) has been developed as a tumor-sensitive contrast and synergistic agent (C&SA) for ultrasound-guided HIFU cancer surgery, by integrating dendritic-structured mesoporous organosilica nanoparticles (MONs) and catalase immobilized in the large open pore channels of MONs. Such a hybrid nanoreactor exhibited sensitive catalytic activity toward H2O2, facilitating the continuous O2 gas generation in a relatively mild manner even if incubated with 10 μM H2O2, which finally led to enhanced ablation in the tissue-mimicking PAA gel model after HIFU exposure mainly resulting from intensified cavitation effect. The C@M nanoparticles could be accumulated within the H2O2-enriched tumor region through enhanced permeability and retention effect, enabling durable contrast enhancement of ultrasound imaging, and highly efficient tumor ablation under relatively low power of HIFU exposure in vivo. Very different from the traditional perfluorocarbon-based C&SA, such an on-demand catalytic nanoreactor could realize the accurate positioning of tumor without HIFU prestimulation and efficient HIFU ablation with a much safer power output, which is highly desired in clinical HIFU application.
Collapse
Affiliation(s)
- Tianzhi Liu
- State Key Laboratory of High Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences , Shanghai 200050, People's Republic of China
- University of Chinese Academy of Sciences , Beijing 100049, People's Republic of China
| | - Nan Zhang
- Second Affiliated Hospital of Chongqing Medical University , Chongqing 400016, People's Republic of China
| | - Zhigang Wang
- Second Affiliated Hospital of Chongqing Medical University , Chongqing 400016, People's Republic of China
| | - Meiying Wu
- State Key Laboratory of High Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences , Shanghai 200050, People's Republic of China
| | - Yu Chen
- State Key Laboratory of High Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences , Shanghai 200050, People's Republic of China
| | - Ming Ma
- State Key Laboratory of High Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences , Shanghai 200050, People's Republic of China
| | - Hangrong Chen
- State Key Laboratory of High Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences , Shanghai 200050, People's Republic of China
| | - Jianlin Shi
- State Key Laboratory of High Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences , Shanghai 200050, People's Republic of China
| |
Collapse
|
39
|
Pattern analysis of laser-tattoo interactions for picosecond- and nanosecond-domain 1,064-nm neodymium-doped yttrium-aluminum-garnet lasers in tissue-mimicking phantom. Sci Rep 2017; 7:1533. [PMID: 28484226 PMCID: PMC5431496 DOI: 10.1038/s41598-017-01724-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2016] [Accepted: 04/03/2017] [Indexed: 11/14/2022] Open
Abstract
During laser treatment for tattoo removal, pigment chromophores absorb laser energy, resulting in fragmentation of the ink particles via selective photothermolysis. The present study aimed to outline macroscopic laser-tattoo interactions in tissue-mimicking (TM) phantoms treated with picosecond- and nanosecond-domain lasers. Additionally, high-speed cinematographs were captured to visualize time-dependent tattoo-tissue interactions, from laser irradiation to the formation of photothermal and photoacoustic injury zones (PIZs). In all experimental settings using the nanosecond or picosecond laser, tattoo pigments fragmented into coarse particles after a single laser pulse, and further disintegrated into smaller particles that dispersed toward the boundaries of PIZs after repetitive delivery of laser energy. Particles fractured by picosecond treatment were more evenly dispersed throughout PIZs than those fractured by nanosecond treatment. Additionally, picosecond-then-picosecond laser treatment (5-pass-picosecond treatment + 5-pass-picosecond treatment) induced greater disintegration of tattoo particles within PIZs than picosecond-then-nanosecond laser treatment (5-pass-picosecond treatment + 5-pass-nanosecond treatment). High-speed cinematography recorded the formation of PIZs after repeated reflection and propagation of acoustic waves over hundreds of microseconds to a few milliseconds. The present data may be of use in predicting three-dimensional laser-tattoo interactions and associated reactions in surrounding tissue.
Collapse
|
40
|
Troia A, Cuccaro R, Schiavi A. Independent tuning of acoustic and mechanical properties of phantoms for biomedical applications of ultrasound. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa5ed0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
41
|
Mikhail AS, Negussie AH, Graham C, Mathew M, Wood BJ, Partanen A. Evaluation of a tissue-mimicking thermochromic phantom for radiofrequency ablation. Med Phys 2017; 43:4304. [PMID: 27370145 DOI: 10.1118/1.4953394] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE This work describes the characterization and evaluation of a tissue-mimicking thermochromic phantom (TMTCP) for direct visualization and quantitative determination of temperatures during radiofrequency ablation (RFA). METHODS TMTCP material was prepared using polyacrylamide gel and thermochromic ink that permanently changes color from white to magenta when heated. Color vs temperature calibration was generated in matlab by extracting RGB color values from digital photographs of phantom standards heated in a water bath at 25-75 °C. RGB and temperature values were plotted prior to curve fitting in mathematica using logistic functions of form f(t) = a + b/(1 + e((c(t-d)))), where a, b, c, and d are coefficients and t denotes temperature. To quantify temperatures based on TMTCP color, phantom samples were heated to temperatures blinded to the investigators, and two methods were evaluated: (1) visual comparison of sample color to the calibration series and (2) in silico analysis using the inverse of the logistic functions to convert sample photograph RGB values to absolute temperatures. For evaluation of TMTCP performance with RFA, temperatures in phantom samples and in a bovine liver were measured radially from an RF electrode during heating using fiber-optic temperature probes. Heating and cooling rates as well as the area under the temperature vs time curves were compared. Finally, temperature isotherms were generated computationally based on color change in bisected phantoms following RFA and compared to temperature probe measurements. RESULTS TMTCP heating resulted in incremental, permanent color changes between 40 and 64 °C. Visual and computational temperature estimation methods were accurate to within 1.4 and 1.9 °C between 48 and 67 °C, respectively. Temperature estimates were most accurate between 52 and 62 °C, resulting in differences from actual temperatures of 0.6 and 1.6 °C for visual and computational methods, respectively. Temperature measurements during RFA using fiber-optic probes matched closely with maximum temperatures predicted by color changes in the TMTCP. Heating rate and cooling rate, as well as the area under the temperature vs time curve were similar for TMTCP and ex vivo liver. CONCLUSIONS The TMTCP formulated for use with RFA can be used to provide quantitative temperature information in mild hyperthermic (40-45 °C), subablative (45-50 °C), and ablative (>50 °C) temperature ranges. Accurate visual or computational estimates of absolute temperatures and ablation zone geometry can be made with high spatial resolution based on TMTCP color. As such, the TMTCP can be used to assess RFA heating characteristics in a controlled, predictable environment.
Collapse
Affiliation(s)
- Andrew S Mikhail
- Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
| | - Ayele H Negussie
- Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
| | - Cole Graham
- Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
| | - Manoj Mathew
- Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
| | - Bradford J Wood
- Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892
| | - Ari Partanen
- Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland 20892 and Clinical Science MR Therapy, Philips, Andover, Massachusetts 01810
| |
Collapse
|
42
|
Tuning acoustic and mechanical properties of materials for ultrasound phantoms and smart substrates for cell cultures. Acta Biomater 2017; 49:368-378. [PMID: 27884775 DOI: 10.1016/j.actbio.2016.11.049] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Revised: 10/24/2016] [Accepted: 11/21/2016] [Indexed: 12/17/2022]
Abstract
Materials with tailored acoustic properties are of great interest for both the development of tissue-mimicking phantoms for ultrasound tests and smart scaffolds for ultrasound mediated tissue engineering and regenerative medicine. In this study, we assessed the acoustic properties (speed of sound, acoustic impedance and attenuation coefficient) of three different materials (agarose, polyacrylamide and polydimethylsiloxane) at different concentrations or cross-linking levels and doped with different concentrations of barium titanate ceramic nanoparticles. The selected materials, besides different mechanical features (stiffness from few kPa to 1.6MPa), showed a wide range of acoustic properties (speed of sound from 1022 to 1555m/s, acoustic impedance from 1.02 to 1.67MRayl and attenuation coefficient from 0.2 to 36.5dB/cm), corresponding to ranges in which natural soft tissues can fall. We demonstrated that this knowledge can be used to build tissue-mimicking phantoms for ultrasound-based medical procedures and that the mentioned measurements enable to stimulate cells with a highly controlled ultrasound dose, taking into account the attenuation due to the cell-supporting scaffold. Finally, we were able to correlate for the first time the bioeffect on human fibroblasts, triggered by piezoelectric barium titanate nanoparticles activated by low-intensity pulsed ultrasound, with a precise ultrasound dose delivered. These results may open new avenues for the development of both tissue-mimicking materials for ultrasound phantoms and smart triggerable scaffolds for tissue engineering and regenerative medicine. STATEMENT OF SIGNIFICANCE This study reports for the first time the results of a systematic acoustic characterization of agarose, polyacrylamide and polydimethylsiloxane at different concentrations and cross-linking extents and doped with different concentrations of barium titanate nanoparticles. These results can be used to build tissue-mimicking phantoms, useful for many ultrasound-based medical procedures, and to fabricate smart materials for stimulating cells with a highly controlled ultrasound dose. Thanks to this knowledge, we correlated for the first time a bioeffect (the proliferation increase) on human fibroblasts, triggered by piezoelectric nanoparticles, with a precise US dose delivered. These results may open new avenues for the development of both tissue-mimicking phantoms and smart triggerable scaffolds for tissue engineering and regenerative medicine.
Collapse
|
43
|
Bui L, Aleid A, Alassaf A, Wilson OC, Raub CB, Frenkel V. Development of a custom biological scaffold for investigating ultrasound-mediated intracellular delivery. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 70:461-470. [DOI: 10.1016/j.msec.2016.09.029] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2016] [Revised: 08/08/2016] [Accepted: 09/12/2016] [Indexed: 01/15/2023]
|
44
|
Ahn KJ, Kim BJ, Cho SB. Simulation of laser-tattoo pigment interaction in a tissue-mimicking phantom using Q-switched and long-pulsed lasers. Skin Res Technol 2016; 23:376-383. [DOI: 10.1111/srt.12346] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2016] [Indexed: 11/29/2022]
Affiliation(s)
- K. J. Ahn
- Department of Science Education; Jeju National University; Jeju Korea
| | - B. J. Kim
- Department of Dermatology; Chung-Ang University College of Medicine; Seoul Korea
| | - S. B. Cho
- Department of Dermatology; Chung-Ang University College of Medicine; Seoul Korea
- Kangskin Sillim Dermatology Clinic; Seoul Korea
| |
Collapse
|
45
|
Menikou G, Yiannakou M, Yiallouras C, Ioannides C, Damianou C. MRI-compatible bone phantom for evaluating ultrasonic thermal exposures. ULTRASONICS 2016; 71:12-19. [PMID: 27261569 DOI: 10.1016/j.ultras.2016.05.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Revised: 05/15/2016] [Accepted: 05/24/2016] [Indexed: 06/05/2023]
Abstract
OBJECTIVE The goal of the proposed study was the development of a magnetic resonance imaging (MRI) compatible bone phantom suitable for evaluating focused ultrasound protocols. MATERIALS AND METHODS High resolution CT images were used to segment femur bone. The segmented model was manufactured with (Acrylonitrile Butadiene Styrene) ABS plastic using a 3-D printer. The surrounding skeletal muscle tissue was mimicked using an agar-silica-evaporated milk gel (2% w/v-2% w/v-40% v/v). MR thermometry was used to evaluate the exposures of the bone phantom to focused ultrasound. RESULTS The estimated agar-silica-evaporated milk gel's T1 and T2 relaxation times in a 1.5T magnetic field were 776ms and 66ms respectively. MR thermometry maps indicated increased temperature adjacent to the bone, which was also shown in situations of real bone/tissue interfaces. CONCLUSION Due to growing interest of using MRI guided Focused Ultrasound Surgery (MRgFUS) in palliating bone cancer patients at terminal stages of the disease, the proposed bone phantom can be utilized as a very useful tool for evaluating ultrasonic protocols, thus minimizing the need for animal models. The estimated temperature measured and its distribution near the bone phantom/agar interface which was similar to temperatures recorded in real bone ablation with FUS, confirmed the phantom's functionality.
Collapse
Affiliation(s)
| | | | - Christos Yiallouras
- Cyprus University of Technology, Limassol, Cyprus; MEDSONIC LTD, Limassol, Cyprus
| | | | | |
Collapse
|
46
|
Jin CS, Overchuk M, Cui L, Wilson BC, Bristow RG, Chen J, Zheng G. Nanoparticle-Enabled Selective Destruction of Prostate Tumor Using MRI-Guided Focal Photothermal Therapy. Prostate 2016; 76:1169-81. [PMID: 27198587 DOI: 10.1002/pros.23203] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Accepted: 04/27/2016] [Indexed: 12/11/2022]
Abstract
BACKGROUND The Magnetic Resonance Imaging (MRI)-guided focal laser therapy has shown early promise in Phase 1 trial treating low/intermediate-risk localized prostate cancer (PCa), but the lack of tumor selectivity and low efficiency of heat generation remain as drawbacks of agent-free laser therapy. Intrinsic multifunctional porphyrin-nanoparticles (porphysomes) have been exploited to treat localized PCa by MRI-guided focal photothermal therapy (PTT) with significantly improved efficiency and tumor selectivity over prior methods of PTT, providing an effective and safe alternative to active surveillance or radical therapy. METHODS The tumor accumulation of porphysomes chelated with copper-64 was determined and compared with the clinic standard (18) F-FDG in an orthotropic PCa mouse model by positron emission tomography (PET) imaging, providing quantitative assessment for PTT dosimetry. The PTT was conducted with MRI-guided light delivery and monitored by MR thermometry, mimicking the clinical protocol. The efficacy of treatment and adverse effects to surround tissues were evaluated by histology analysis and tumor growth in survival study via MRI. RESULTS Porphysomes showed superior tumor-to-prostate selectivity over (18) F-FDG (6:1 vs. 0.36:1). MR thermometry detected tumor temperature increased to ≥55°C within 2 min (671 nm at 500 mW), but minimal increase in surrounding tissues. Porphysome enabled effective PTT eradication of tumor without damaging adjacent organs in orthotropic PCa mouse model. CONCLUSIONS Porphysome-enabled MRI-guided focal PTT could be an effective and safe approach to treat PCa at low risk of progression, thus addressing the significant unmet clinical needs and benefiting an ever-growing number of patients who may be over-treated and risk unnecessary side effects from radical therapies. Prostate 76:1169-1181, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Cheng S Jin
- Princess Margaret Cancer Center, UHN, Toronto, Canada
- Faculty of Pharmacy, Department of Pharmaceutical Sciences, University of Toronto, Toronto, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada
| | - Marta Overchuk
- Princess Margaret Cancer Center, UHN, Toronto, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada
| | - Liyang Cui
- Princess Margaret Cancer Center, UHN, Toronto, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
- Medical Isotopes Research Center, Peking University, Beijing, China
| | - Brian C Wilson
- Princess Margaret Cancer Center, UHN, Toronto, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Robert G Bristow
- Princess Margaret Cancer Center, UHN, Toronto, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Juan Chen
- Princess Margaret Cancer Center, UHN, Toronto, Canada
| | - Gang Zheng
- Princess Margaret Cancer Center, UHN, Toronto, Canada
- Faculty of Pharmacy, Department of Pharmaceutical Sciences, University of Toronto, Toronto, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
47
|
Sheikhi A, Hill RJ. Hydrogel-colloid interfacial interactions: a study of tailored adhesion using optical tweezers. SOFT MATTER 2016; 12:6575-6587. [PMID: 27425660 DOI: 10.1039/c6sm00903d] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Dynamics of colloidal particles adhering to soft, deformable substrates, such as tissues, biofilms, and hydrogels play a key role in many biological and biomimetic processes. These processes, including, but not limited to colloid-based delivery, stitching, and sorting, involve microspheres exploring the vicinity of soft, sticky materials in which the colloidal dynamics are affected by the fluid environment (e.g., viscous coupling), inter-molecular interactions between the colloids and substrates (e.g., Derjaguin-Landau-Verwey-Overbeek (DLVO) theory), and the viscoelastic properties of contact region. To better understand colloidal dynamics at soft interfaces, an optical tweezers back-focal-plane interferometry apparatus was developed to register the transverse Brownian motion of a silica microsphere in the vicinity of polyacrylamide (PA) hydrogel films. The time-dependent mean-squared displacements are well described by a single exponential relaxation, furnishing measures of the transverse interfacial diffusion coefficient and binding stiffness. Substrates with different elasticities were prepared by changing the PA crosslinking density, and the inter-molecular interactions were adjusted by coating the microspheres with fluid membranes. Stiffer PA hydrogels (with bulk Young's moduli ≈1-10 kPa) immobilize the microspheres more firmly (lower diffusion coefficient and position variance), and coating the particles with zwitterionic lipid bilayers (DOPC) completely eliminates adhesion, possibly by repulsive dispersion forces. Remarkably, embedding polyethylene glycol-grafted lipid bilayers (DSPE-PEG2k-Amine) in the zwitterionic fluid membranes produces stronger adhesion, possibly because of polymer-hydrogel attraction and entanglement. This study provides new insights to guide the design of nanoparticles and substrates with tunable adhesion, leading to smarter delivery, sorting, and screening of micro- and nano-systems.
Collapse
Affiliation(s)
- Amir Sheikhi
- Department of Chemical Engineering, McGill University, 3610 University Street, Montreal, Quebec H3A 0C5, Canada.
| | | |
Collapse
|
48
|
Jin CS, Wada H, Anayama T, McVeigh PZ, Hu HP, Hirohashi K, Nakajima T, Kato T, Keshavjee S, Hwang D, Wilson BC, Zheng G, Yasufuku K. An Integrated Nanotechnology-Enabled Transbronchial Image-Guided Intervention Strategy for Peripheral Lung Cancer. Cancer Res 2016; 76:5870-5880. [PMID: 27543602 DOI: 10.1158/0008-5472.can-15-3196] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Accepted: 06/07/2016] [Indexed: 12/25/2022]
Abstract
Early detection and efficient treatment modality of early-stage peripheral lung cancer is essential. Current nonsurgical treatments for peripheral lung cancer show critical limitations associated with various complications, requiring alternative minimally invasive therapeutics. Porphysome nanoparticle-enabled fluorescence-guided transbronchial photothermal therapy (PTT) of peripheral lung cancer was developed and demonstrated in preclinical animal models. Systemically administered porphysomes accumulated in lung tumors with significantly enhanced disease-to-normal tissue contrast, as confirmed in three subtypes of orthotopic human lung cancer xenografts (A549, H460, and H520) in mice and in an orthotopic VX2 tumor in rabbits. An in-house prototype fluorescence bronchoscope demonstrated the capability of porphysomes for in vivo imaging of lung tumors in the mucosal/submucosal layers, providing real-time fluorescence guidance for transbronchial PTT. Porphysomes also enhanced the efficacy of transbronchial PTT significantly and resulted in selective and efficient tumor tissue ablation in the rabbit model. A clinically used cylindrical diffuser fiber successfully achieved tumor-specific thermal ablation, showing promising evidence for the clinical translation of this novel platform to impact upon nonsurgical treatment of early-stage peripheral lung cancer. Cancer Res; 76(19); 5870-80. ©2016 AACR.
Collapse
Affiliation(s)
- Cheng S Jin
- Graduate Department of Pharmaceutical Sciences, Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Ontario, Canada. Institute of Biomaterial and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada. Princess Margaret Cancer Centre and TECHNA Institute, University Health Network, Toronto, Ontario, Canada
| | - Hironobu Wada
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada
| | - Takashi Anayama
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada
| | - Patrick Z McVeigh
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Hsin Pei Hu
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada
| | - Kentaro Hirohashi
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada
| | - Takahiro Nakajima
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada
| | - Tatsuya Kato
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada
| | - Shaf Keshavjee
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada
| | - David Hwang
- Division of Experimental Therapeutics, Respiratory & Critical Care, Princess Margaret Cancer Centre, Toronto, Ontario, Canada
| | - Brian C Wilson
- Princess Margaret Cancer Centre and TECHNA Institute, University Health Network, Toronto, Ontario, Canada. Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Gang Zheng
- Graduate Department of Pharmaceutical Sciences, Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Ontario, Canada. Institute of Biomaterial and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada. Princess Margaret Cancer Centre and TECHNA Institute, University Health Network, Toronto, Ontario, Canada. Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
| | - Kazuhiro Yasufuku
- Princess Margaret Cancer Centre and TECHNA Institute, University Health Network, Toronto, Ontario, Canada. Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada.
| |
Collapse
|
49
|
Pahk KJ, Mohammad GH, Malago M, Saffari N, Dhar DK. A Novel Approach to Ultrasound-Mediated Tissue Decellularization and Intra-Hepatic Cell Delivery in Rats. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:1958-1967. [PMID: 27184248 DOI: 10.1016/j.ultrasmedbio.2016.03.020] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Revised: 03/10/2016] [Accepted: 03/20/2016] [Indexed: 06/05/2023]
Abstract
Liver transplantation is the mainstay of treatment for end stage liver diseases, including metabolic and congenital liver diseases. The number of suitable donor organs is, however, limited, and a whole-liver transplant requires complex surgery. Cell therapy, such as intra-portal hepatocytes transplantation, has been considered as a bridging therapy to liver transplantation but has shown a mixed clinical outcome with limited success, including low level of engraftment of transplanted hepatocytes. Here, we report a novel cell delivery technique in a rat model by creating a cavity inside the liver parenchyma by non-invasive high intensity focused ultrasound histotripsy. Our in vivo experimental results together with histologic observations show that direct injection of cells inside the cavity can facilitate successful uptake, proliferation and integration of the transplanted hepatocytes in the recipient liver. We were able to restore the plasma albumin level to 50% of the normal level in Nagase analbuminemic rats (serum albumin level of the Nagase rats was initially nil) by cell therapy after high intensity focused ultrasound-mediated histotripsy. We believe that this novel technique would enable the delivery of a large number of cells into the liver to restore liver function, particularly as a treatment for metabolic liver diseases. This novel method of intra-hepatic hepatocyte transplantation might be an invaluable tool for cell therapy in the future.
Collapse
Affiliation(s)
- Ki Joo Pahk
- Department of Mechanical Engineering, University College London, London, UK
| | - Goran Hamid Mohammad
- Institute for Liver and Digestive Health, Royal Free Hospital, University College London, London, UK
| | - Massimo Malago
- Hepato-pancreatic-biliary and Liver Transplantation Surgery, Royal Free Hospital, University College London, London, UK
| | - Nader Saffari
- Department of Mechanical Engineering, University College London, London, UK.
| | - Dipok Kumar Dhar
- Institute for Liver and Digestive Health, Royal Free Hospital, University College London, London, UK; King Faisal Specialist Hospital and Research Center, Comparative Medicine Department and Organ Transplantation Center, Riyadh, Saudi Arabia
| |
Collapse
|
50
|
Ng KK, Weersink RA, Lim L, Wilson BC, Zheng G. Controlling Spatial Heat and Light Distribution by Using Photothermal Enhancing Auto-Regulated Liposomes (PEARLs). Angew Chem Int Ed Engl 2016; 55:10003-7. [PMID: 27411830 DOI: 10.1002/anie.201605241] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2016] [Indexed: 01/07/2023]
Abstract
Photothermal therapy (PTT) is enhanced by the use of nanoparticles with a large optical absorption at the treatment wavelength. However, this comes at the cost of higher light attenuation that results in reduced depth of heating as well as larger thermal gradients, leading to potential over- and under-treatment in the target tissue. These limitations can be overcome by using photothermal enhancing auto-regulating liposomes (PEARLs), based on thermochromic J-aggregate forming dye-lipid conjugates that reversibly alter their absorption above a predefined lipid phase-transition temperature. Under irradiation by near-infrared light, deeper layers of the target tissue revert to the intrinsic optical absorption, halting the temperature rise and enabling greater light penetration and heat generation at depth. This effect is demonstrated in both nanoparticle solutions and in gel phantoms containing the nanoparticles.
Collapse
Affiliation(s)
- Kenneth K Ng
- Princess Margaret Cancer Centre and TECHNA Institute, University Health Network, Toronto, ON, M5G 1L7, Canada
| | - Robert A Weersink
- Princess Margaret Cancer Centre and TECHNA Institute, University Health Network, Toronto, ON, M5G 1L7, Canada
| | - Liang Lim
- Princess Margaret Cancer Centre and TECHNA Institute, University Health Network, Toronto, ON, M5G 1L7, Canada
| | - Brian C Wilson
- Princess Margaret Cancer Centre and TECHNA Institute, University Health Network, Toronto, ON, M5G 1L7, Canada.,Department of Medical Biophysics, University of Toronto, Ontario, M5G 1L7, Canada
| | - Gang Zheng
- Princess Margaret Cancer Centre and TECHNA Institute, University Health Network, Toronto, ON, M5G 1L7, Canada. .,Department of Medical Biophysics, University of Toronto, Ontario, M5G 1L7, Canada.
| |
Collapse
|