1
|
Emori T, Nuta J, Kawaji Y, Tamura T, Hatamaru K, Itonaga M, Yamashita Y, Ashida R, Shimokawa T, Koike M, Ikoma A, Sonomura T, Kawai M, Kitano M. Value of contrast-enhanced harmonic endoscopic ultrasound for diagnosing hepatic metastases of pancreatic cancer: A prospective study. J Gastroenterol Hepatol 2021; 36:3402-3409. [PMID: 34397113 DOI: 10.1111/jgh.15661] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 08/02/2021] [Accepted: 08/07/2021] [Indexed: 02/06/2023]
Abstract
BACKGROUND AND AIMS This study aimed to compare contrast-enhanced harmonic endoscopic ultrasound (CH-EUS) with fundamental B-mode endoscopic ultrasonography (EUS) and contrast-enhanced computed tomography (CE-CT) for the diagnosis of left hepatic lobe metastases of pancreatic adenocarcinoma. METHODS In this single-center prospective study, CE-CT, EUS, and CH-EUS were performed to detect left hepatic lobe metastases in patients with pancreatic adenocarcinoma, and the detection rates were compared between EUS plus CH-EUS and the other two modalities. Subgroup comparisons of between-modality detection rate were performed in patients with only metastases of <10 mm. The number of pancreatic adenocarcinoma patients whose clinical stage and treatment strategy were changed because of EUS plus CH-EUS findings was also assessed. RESULTS Thirty-one patients were diagnosed with left hepatic lobe metastases. For overall detection of left hepatic lobe metastases, EUS plus CH-EUS had significantly higher accuracy (94.3%) than CE-CT (86.7%) and EUS alone (87.6%) (P = 0.021 and P = 0.020, respectively). For detection of left hepatic lobe metastases < 10 mm, EUS plus CH-EUS (93.3%) was significantly superior to CE-CT (84.4%) and EUS alone (85.6%) (P = 0.021 and P = 0.020, respectively). In five of the 11 patients in whom only CH-EUS allowed detection of hepatic metastases, the stage and/or treatment strategy of the pancreatic adenocarcinoma was changed after CH-EUS. CONCLUSION This study demonstrated that EUS plus CH-EUS has advantages over CE-CT and EUS alone with regard to the accuracy of detecting left hepatic lobe metastases, particularly small hepatic metastases and accurate staging.
Collapse
Affiliation(s)
- Tomoya Emori
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Junya Nuta
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Yuki Kawaji
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Takashi Tamura
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Keiichi Hatamaru
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Masahiro Itonaga
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Yasunobu Yamashita
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Reiko Ashida
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Toshio Shimokawa
- Clinical Study Support Center, Wakayama Medical University, Wakayama, Japan
| | - Masataka Koike
- Department of Radiology, Wakayama Medical University, Wakayama, Japan
| | - Akira Ikoma
- Department of Radiology, Wakayama Medical University, Wakayama, Japan
| | - Tetsuo Sonomura
- Department of Radiology, Wakayama Medical University, Wakayama, Japan
| | - Manabu Kawai
- Second Department of Surgery, Wakayama Medical University, Wakayama, Japan
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| |
Collapse
|
2
|
Chernyak V, Horowitz JM, Kamel IR, Arif-Tiwari H, Bashir MR, Cash BD, Farrell J, Goldstein A, Grajo JR, Gupta S, Hindman NM, Kamaya A, McNamara MM, Porter KK, Solnes LB, Srivastava PK, Zaheer A, Carucci LR. ACR Appropriateness Criteria® Liver Lesion-Initial Characterization. J Am Coll Radiol 2020; 17:S429-S446. [PMID: 33153555 DOI: 10.1016/j.jacr.2020.09.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 09/01/2020] [Indexed: 02/08/2023]
Abstract
Incidental liver masses are commonly identified on imaging performed for other indications. Since the prevalence of benign focal liver lesions in adults is high, even in patients with primary malignancy, accurate characterization of incidentally detected lesions is of paramount clinical importance. This document reviews utilization of various imaging modalities for characterization of incidentally detected liver lesions, discussed in the context of several clinical scenarios. For each clinical scenario, a summary of current evidence supporting the use of a given diagnostic modality is reported. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
Collapse
Affiliation(s)
| | | | - Ihab R Kamel
- Panel Chair, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Hina Arif-Tiwari
- University of Arizona, Banner University Medical Center, Tucson, Arizona
| | | | - Brooks D Cash
- University of Texas Health Science Center at Houston and McGovern Medical School, Houston, Texas; American Gastroenterological Association
| | - James Farrell
- Interventional Endoscopy and Pancreatic Diseases, New Haven, Connecticut; American Gastroenterological Association
| | | | - Joseph R Grajo
- University of Florida College of Medicine, Gainesville, Florida
| | - Samir Gupta
- Rush University Medical Center, Chicago, Illinois; American College of Surgeons
| | | | - Aya Kamaya
- Stanford University Medical Center, Stanford, California
| | | | | | | | - Pavan K Srivastava
- University of Illinois College of Medicine, Chicago, Illinois; American College of Physicians
| | | | - Laura R Carucci
- Specialty Chair, Virginia Commonwealth University Medical Center, Richmond, Virginia
| |
Collapse
|
3
|
Chen XP, Liu J, Zhou J, Zhou PC, Shu J, Xu LL, Li B, Su S. Combination of CEUS and MRI for the diagnosis of periampullary space-occupying lesions: a retrospective analysis. BMC Med Imaging 2019; 19:77. [PMID: 31477041 PMCID: PMC6719361 DOI: 10.1186/s12880-019-0376-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Accepted: 08/23/2019] [Indexed: 12/18/2022] Open
Abstract
Background The value of magnetic resonance imaging (MRI), contrast-enhanced ultrasound (CEUS), and the combination of CEUS and MRI (CCWM) for the diagnosis of periampullary space-occupying lesions (PSOL) was investigated. Methods A total of 102 patients diagnosed with PSOLs by surgery or biopsy were recruited retrospectively. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of MRI, CEUS, and CCWM were analyzed. Results MRI, CEUS, and CCWM allowed for the accurate detection of 91.17, 92.15, and 99.01% of PSOLs, respectively. The specificity, PPV, and accuracy of CCWM were significantly different from MRI and CEUS (p < 0.05). However, there the sensitivity and NPV were not significantly different among the three diagnostic technologies. In addition, the specificity, PPV, and accuracy were not significantly different between MRI and CEUS (all p > 0.05). Conclusions CCWM is valuable for differentiating benign and malignant PSOL, which provides important guiding significances for the clinic.
Collapse
Affiliation(s)
- Xin-Pei Chen
- Department of Hepatobiliary Surgery, The Affiliated Hospital of Southwest Medical University, No. 25 Taiping Street, Jiangyang District, Luzhou, 646000, Sichuan Province, China
| | - Jiang Liu
- Department of Nephrology, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, Sichuan Province, China
| | - Jing Zhou
- Department of Ultrasonics, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, Sichuan Province, China
| | - Peng-Cheng Zhou
- Department of Hepatobiliary Surgery, The Affiliated Hospital of Southwest Medical University, No. 25 Taiping Street, Jiangyang District, Luzhou, 646000, Sichuan Province, China
| | - Jian Shu
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, Sichuan Province, China
| | - Lu-Lu Xu
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, Sichuan Province, China
| | - Bo Li
- Department of Hepatobiliary Surgery, The Affiliated Hospital of Southwest Medical University, No. 25 Taiping Street, Jiangyang District, Luzhou, 646000, Sichuan Province, China
| | - Song Su
- Department of Hepatobiliary Surgery, The Affiliated Hospital of Southwest Medical University, No. 25 Taiping Street, Jiangyang District, Luzhou, 646000, Sichuan Province, China.
| |
Collapse
|
4
|
Sibinga Mulder BG, Feshtali S, Fariña Sarasqueta A, Vahrmeijer AL, Swijnenburg RJ, Bonsing BA, Mieog JSD. A Prospective Clinical Trial to Determine the Effect of Intraoperative Ultrasound on Surgical Strategy and Resection Outcome in Patients with Pancreatic Cancer. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2019-2026. [PMID: 31130412 DOI: 10.1016/j.ultrasmedbio.2019.04.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 04/07/2019] [Accepted: 04/24/2019] [Indexed: 06/09/2023]
Abstract
Surgical exploration in patients with pancreatic or periampullary cancer is often performed without intraoperative image guidance. Although intraoperative ultrasound (IOUS) may enhance visualization during resection, this tool has not been investigated in detail until now. Here, we performed a prospective cohort study to evaluate the effect of IOUS on surgical strategy and to evaluate whether vascular involvement and radicality of the resection could be correctly assessed with IOUS. IOUS was performed by an experienced abdominal radiologist during surgical exploration in 31 consecutive procedures. IOUS affected surgical strategy by either (i) having no effect, (ii) determining tumor localization, (iii) evaluating vascular involvement or (iv) waiving surgery. Radicality of the resections and vascular contact were determined during pathologic analysis and compared with preoperative imaging and IOUS findings. Overall, IOUS influenced surgical strategy in 61% of procedures. In 21 out of 27 malignant tumors, a radical resection was achieved (78%). Vascular contact was assessed correctly using IOUS in 89% compared with 74% of patients using preoperative imaging. IOUS can help the surgical team to assess the resectability and to visualize the tumor and possible vascular contact in real time during resection. IOUS may therefore increase the likelihood of achieving a radical resection.
Collapse
Affiliation(s)
| | - Shirin Feshtali
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | | | | | | | - Bert A Bonsing
- Department of Surgery, Leiden University Medical Center, Leiden, the Netherlands
| | - J Sven D Mieog
- Department of Surgery, Leiden University Medical Center, Leiden, the Netherlands.
| |
Collapse
|
5
|
Huang R, Jiang L, Xu Y, Gong Y, Ran H, Wang Z, Sun Y. Comparative Diagnostic Accuracy of Contrast-Enhanced Ultrasound and Shear Wave Elastography in Differentiating Benign and Malignant Lesions: A Network Meta-Analysis. Front Oncol 2019; 9:102. [PMID: 30891425 PMCID: PMC6412152 DOI: 10.3389/fonc.2019.00102] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Accepted: 02/04/2019] [Indexed: 12/12/2022] Open
Abstract
Background: We performed a network meta-analysis to compare the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) and shear wave elastography (SWE) in differentiating benign and malignant lesions in different body sites. Methods: A computerized literature search of Medline, Embase, SCOPUS, and Web of Science was performed using relevant keywords. Following data extraction, we calculated sensitivity, specificity, positive likelihood ratio (LR), negative LR, and diagnostic odds ratio (DOR) for CEUS, and SWE compared to histopathology as a reference standard. Statistical analyses were conducted by MetaDiSc (version 1.4) and R software (version 3.4.3). Results: One hundred and fourteen studies (15,926 patients) were pooled in the final analyses. Network meta-analysis showed that CEUS had significantly higher DOR than SWE (DOR = 27.14, 95%CI [2.30, 51.97]) in breast cancer detection. However, there were no significant differences between CEUS and SWE in hepatic (DOR = −6.67, 95%CI [−15.08, 1.74]) and thyroid cancer detection (DOR = 3.79, 95%CI [−3.10, 10.68]). Interestingly, ranking analysis showed that CEUS achieved higher DOR in detecting breast and thyroid cancer, while SWE achieved higher DOR in detecting hepatic cancer. The overall DOR for CEUS in detecting renal cancer was 53.44, 95%CI [29.89, 95.56] with an AUROC of 0.95, while the overall DOR for SWE in detecting prostate cancer was 25.35, 95%CI [7.15, 89.89] with an AUROC of 0.89. Conclusion: Both diagnostic tests showed relatively high sensitivity and specificity in detecting malignant tumors in different organs. Network meta-analysis showed that CEUS had higher diagnostic accuracy than SWE in detecting breast and thyroid cancer, while SWE had higher accuracy in detecting hepatic cancer. However, the results were not statistically significant in hepatic and thyroid malignancies. Further head-to-head comparisons are needed to confirm the optimal imaging technique to differentiate each cancer type.
Collapse
Affiliation(s)
- Rongzhong Huang
- The First People's Hospital of Yunnan Province, Kunming, China
| | - Lihong Jiang
- The First People's Hospital of Yunnan Province, Kunming, China
| | - Yu Xu
- Chuangxu Institute of Life Science, Chongqing, China
| | - Yuping Gong
- Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Haitao Ran
- Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Zhigang Wang
- Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Yang Sun
- Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
6
|
Characterization of Focal Liver Lesions Indistinctive on B Mode Ultrasound: Benefits of Contrast-Enhanced Ultrasound. BIOMED RESEARCH INTERNATIONAL 2017; 2017:8970156. [PMID: 28497069 PMCID: PMC5405373 DOI: 10.1155/2017/8970156] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Accepted: 03/30/2017] [Indexed: 12/12/2022]
Abstract
Aim. The aim of this prospective study was to evaluate the additional value of contrast-enhanced ultrasound (CEUS) in identifying and characterizing of focal liver lesions (FLLs) that are indistinctive on B mode ultrasound (BMUS). Methods. The study focused on 70 consecutive patients (male 46, female 24; mean age, 53.1 years ± 10). All lesions were detected by MRI but could not be clearly visualized by BMUS. CEUS was performed by injected SonoVue® (Bracco Imaging Spa, Milan, Italy) as a quick bolus into the antecubital vein. All lesions were proved by pathologic and MRI findings as primary or metastatic hepatic malignancies. Results. On CEUS, 45 (64.2%) FLLs displayed arterial hyperenhancement and 55 (78.5%) lesions showed hypoenhancement in portal venous and late phase (PVLP). Homogeneous and complete hyperenhancement pattern during the arterial phase is highly suspicious for HCC in liver cirrhosis (96.8%). Arterial isoenhancement and early washout during PVLP are characteristic for metastasis (73.3%). For recurrence lesions, arterial hyperenhancement and isoenhancement during PVLP are more common (60%). Conclusion. CEUS may provide added diagnostic values in FLLs appearing indistinctive on BMUS. Presence of early arterial enhancement and washout during PVLP may be helpful for detection of those lesions.
Collapse
|
7
|
Zhuang PH, Xu L, Gao L, Lu W, Ruan LT, Yang J. Correlations of microvascular blood flow of contrast-enhanced ultrasound and HGF/c-Met signaling pathway with clinicopathological features and prognosis of patients with hepatocellular carcinoma. Onco Targets Ther 2017; 10:847-857. [PMID: 28243120 PMCID: PMC5317332 DOI: 10.2147/ott.s113353] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
The study is designed to explore the correlations of microvascular blood flow of contrast-enhanced ultrasound (CEUS) and hepatocyte growth factor (HGF)/c-Met signaling pathway with clinicopathological features and prognosis of patients with hepatocellular carcinoma (HCC). One hundred and eighteen patients pathologically diagnosed as primary HCC were selected. All HCC patients underwent CEUS examination before operation. HCC tissues and adjacent normal tissue specimens were obtained to detect the protein rates of HGF and c-Met expressions by immunohistochemistry. The mRNA expressions of HGF and c-Met were detected by quantitative real-time polymerase chase reaction assay. The microvessel density (MVD) was tested by CD34 immunohistochemistry. Compared with liver parenchyma, the HCC lesions had higher MVD, preoperative peak intensity (PI), area under the curve (AUC), lower preoperative time to peak (TTP), and washout time (WOT). Compared with adjacent normal tissues, the protein and mRNA expressions of HGF were reduced in HCC tissues, but the protein and mRNA expressions of c-Met and MVD were increased. The protein expressions of HGF and c-Met exhibited evident correlations with TNM stage, tumor size, vascular invasion, liver cirrhosis, and hepatitis B virus and hepatitis C virus infection of HCC patients. The tumor size and number, vascular invasion, the protein expressions of HGF and c-Met, and MVD were associated with the TTP, PI, WOT, and AUC of CEUS in HCC patients. The protein expressions of HGF and c-Met, MVD and preoperative PI revealed negative associations with the prognosis of HCC patients. In conclusion, quantitative parameters of CEUS and HGF/c-Met signaling pathway-related proteins may be helpful for early diagnosis and prognosis prediction of HCC patients.
Collapse
Affiliation(s)
| | | | - Lu Gao
- Department of Internal Medicine, The Hospital of Xi'an Jiao Tong University
| | - Wei Lu
- Department of Gastroenterology, Xi'an First Hospital
| | - Li-Tao Ruan
- Department of Ultrasound, The First Affiliated Hospital of Xi'an Jiao Tong University, Xi'an, People's Republic of China
| | | |
Collapse
|
8
|
Bartolotta TV, Vernuccio F, Taibbi A, Lagalla R. Contrast-Enhanced Ultrasound in Focal Liver Lesions: Where Do We Stand? Semin Ultrasound CT MR 2016; 37:573-586. [PMID: 27986175 DOI: 10.1053/j.sult.2016.10.003] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Contrast-enhanced ultrasound (CEUS) represents a significant breakthrough in sonography, and it is being increasingly used for the evaluation of focal liver lesions (FLLs). Currently, CEUS is included as a part of the suggested diagnostic workup of FLLs, resulting in a better patient management and delivering cost-effective therapy. After a brief technical note, contrast-enhancement patterns of different types of benign and malignant FLLs, along with hepatic pseudolesions, are described and discussed based on our experience and literature data. At the same time, the most recent concepts and the use of CEUS in different clinical settings are presented.
Collapse
Affiliation(s)
| | - Federica Vernuccio
- Section of Radiology, DIBIMED, University Hospital "Paolo Giaccone", Palermo, Italy
| | - Adele Taibbi
- Section of Radiology, DIBIMED, University Hospital "Paolo Giaccone", Palermo, Italy
| | - Roberto Lagalla
- Section of Radiology, DIBIMED, University Hospital "Paolo Giaccone", Palermo, Italy
| |
Collapse
|
9
|
Liu Y, Wu H, Zhou Q, Gou J, Xu J, Liu Y, Chen Q. Diagnostic Value of Conventional Ultrasonography Combined with Contrast-Enhanced Ultrasonography in Thyroid Imaging Reporting and Data System (TI-RADS) 3 and 4 Thyroid Micronodules. Med Sci Monit 2016; 22:3086-94. [PMID: 27580248 PMCID: PMC5015597 DOI: 10.12659/msm.897011] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
BACKGROUND The present study was conducted to investigate the diagnostic performance of conventional ultrasonography (US) combined with contrast-enhanced ultrasonography (CEUS) in thyroid micronodules with thyroid imaging reporting and data system (TI-RADS) category 3 and 4. MATERIAL AND METHODS The features of conventional US and CEUS ion 102 case of thyroid micronodule samples, which were diagnosed based on pathological and clinical examination, were retrospectively analyzed. Logistic regression analysis was used to analyze the diagnostic accuracy in malignant thyroid micronodules. Receiver operator characteristic (ROC) curve was used to assess the performance of those 2 technologies. RESULTS A significant difference in age was found between the benign and malignant groups. The benign and malignant groups showed significant differences in shape, margin, aspect ratio (A/T) ≥1, microcalcification, suspicious lymph gland, enhancement time, enhancement pattern, enhancement intensity, nodule sizes, enhancement margins, and rim-like enhancement. Logistic regression analysis of conventional US showed that A/T ≥1, irregular shape, microcalcification, and suspicious lymph glands are risk factors for thyroid micronodules, while logistic regression analysis of CEUS showed that slow enhancement time and absence of rim-like enhancement are risk factors for thyroid micronodules. Logistic regression analysis of conventional US combined with CEUS demonstrated that A/T ≥1, microcalcification, suspicious lymph gland, slow enhancement time, and absence with rim-like enhancement are risk factors. The ROC curve for conventional US, CEUS, and conventional US combined with CEUS were 90.0%, 90.7%, 99.0%, respectively. CONCLUSIONS Our results show that conventional US combined with CEUS had superior diagnostic performance for TI-RADS 3 and 4 thyroid micronodules compared with conventional US and CEUS alone.
Collapse
Affiliation(s)
- Yingxian Liu
- Department of Ultrasound Diagnosis, China Meitan General Hospital, Beijing, China (mainland)
| | - Hao Wu
- Department of Ultrasound Diagnosis, Sichuan Provincial People's Hospital, Chengdu, Sichuan, China (mainland)
| | - Qing Zhou
- Department of Ultrasound Diagnosis, Sichuan Provincial People's Hospital, Chengdu, Sichuan, China (mainland)
| | - Jiamei Gou
- Department of Ultrasound Diagnosis, The Sixth People's Hospital of Chengdu, Chengdu, Sichuan, China (mainland)
| | - Jinmei Xu
- Department of Ultrasound Diagnosis, China Meitan General Hospital, Beijing, China (mainland)
| | - Yan Liu
- Department of Ultrasound Diagnosis, China Meitan General Hospital, Beijing, China (mainland)
| | - Qin Chen
- Department of Ultrasound Diagnosis, Sichuan Provincial People's Hospital, Chengdu, Sichuan, China (mainland)
| |
Collapse
|