1
|
Fernandes DA. Comprehensive Review on Bubbles: Synthesis, Modification, Characterization and Biomedical Applications. Bioconjug Chem 2024; 35:1639-1686. [PMID: 39377727 DOI: 10.1021/acs.bioconjchem.4c00137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/09/2024]
Abstract
Accurate detection, treatment, and imaging of diseases are important for effective treatment outcomes in patients. In this regard, bubbles have gained much attention, due to their versatility. Bubbles usually 1 nm to 10 μm in size can be produced and loaded with a variety of lipids, polymers, proteins, and therapeutic and imaging agents. This review details the different production and loading methods for bubbles, for imaging and treatment of diseases/conditions such as cancer, tumor angiogenesis, thrombosis, and inflammation. Bubbles can also be used for perfusion measurements, important for diagnostic and therapeutic decision making in cardiac disease. The different factors important in the stability of bubbles and the different techniques for characterizing their physical and chemical properties are explained, for developing bubbles with advanced therapeutic and imaging features. Hence, the review provides important insights for researchers studying bubbles for biomedical applications.
Collapse
|
2
|
López-Aguirre M, Castillo-Ortiz M, Viña-González A, Blesa J, Pineda-Pardo JA. The road ahead to successful BBB opening and drug-delivery with focused ultrasound. J Control Release 2024; 372:901-913. [PMID: 38971426 DOI: 10.1016/j.jconrel.2024.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 06/26/2024] [Accepted: 07/03/2024] [Indexed: 07/08/2024]
Abstract
This review delves into the innovative technology of Blood-Brain Barrier (BBB) opening with low-intensity focused ultrasound in combination with microbubbles (LIFU-MB), a promising therapeutic modality aimed at enhancing drug delivery to the central nervous system (CNS). The BBB's selective permeability, while crucial for neuroprotection, significantly hampers the efficacy of pharmacological treatments for CNS disorders. LIFU-MB emerges as a non-invasive and localized method to transiently increase BBB permeability, facilitating the delivery of therapeutic molecules. Here, we review the procedural stages of LIFU-MB interventions, including planning and preparation, sonication, evaluation, and delivery, highlighting the technological diversity and methodological challenges encountered in current clinical applications. With an emphasis on safety and efficacy, we discuss the crucial aspects of ultrasound delivery, microbubble administration, acoustic feedback monitoring and assessment of BBB permeability. Finally, we explore the critical choices for effective BBB opening with LIFU-MB, focusing on selecting therapeutic agents, optimizing delivery methods, and timing for delivery. Overcoming existing barriers to integrate this technology into clinical practice could potentially revolutionize CNS drug delivery and treatment paradigms in the near future.
Collapse
Affiliation(s)
- Miguel López-Aguirre
- HM CINAC (Centro Integral de Neurociencias Abarca Campal), Hospital Universitario HM Puerta del Sur, HM Hospitales, Madrid, Spain; Instituto de Investigación Sanitaria HM Hospitales, Spain; PhD Program in Physics, Complutense University of Madrid, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Neurodegenerativas (CIBERNED), Instituto de Salud Carlos III, Madrid, Spain
| | - Marta Castillo-Ortiz
- HM CINAC (Centro Integral de Neurociencias Abarca Campal), Hospital Universitario HM Puerta del Sur, HM Hospitales, Madrid, Spain; Instituto de Investigación Sanitaria HM Hospitales, Spain; PhD Program in Technologies for Health and Well-being, Polytechnic University of Valencia, Valencia, Spain; Molecular Imaging Technologies Research Institute (I3M), Polytechnic University of Valencia, Valencia, Spain
| | - Ariel Viña-González
- HM CINAC (Centro Integral de Neurociencias Abarca Campal), Hospital Universitario HM Puerta del Sur, HM Hospitales, Madrid, Spain; Instituto de Investigación Sanitaria HM Hospitales, Spain; PhD Program in Biomedical Engineering, Polytechnic University of Madrid, Madrid, Spain
| | - Javier Blesa
- HM CINAC (Centro Integral de Neurociencias Abarca Campal), Hospital Universitario HM Puerta del Sur, HM Hospitales, Madrid, Spain; Instituto de Investigación Sanitaria HM Hospitales, Spain; Facultad HM de Ciencias de la Salud de la Universidad Camilo José Cela, Madrid, Spain
| | - José A Pineda-Pardo
- HM CINAC (Centro Integral de Neurociencias Abarca Campal), Hospital Universitario HM Puerta del Sur, HM Hospitales, Madrid, Spain; Instituto de Investigación Sanitaria HM Hospitales, Spain.
| |
Collapse
|
3
|
Sojahrood AJ, Yang C, Counil C, Nittayacharn P, Goertz DE, Exner AA, Kolios MC. Influence of the liquid ionic strength on the resonance frequency and shell parameters of lipid-coated microbubbles. J Colloid Interface Sci 2024; 664:533-538. [PMID: 38484521 DOI: 10.1016/j.jcis.2024.01.185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 01/13/2024] [Accepted: 01/26/2024] [Indexed: 04/07/2024]
Abstract
The correct measurement of the resonance frequency and shell properties of coated microbubbles (MBs) is essential in understanding and optimizing their response to ultrasound (US) exposure parameters. In diagnostic and therapeutic ultrasound, MBs are typically surrounded by blood; however, the influence of the medium charges on the MB resonance frequency has not been systematically studied using controlled measurements. This study aims to measure the medium charge interactions on MB behavior by measuring the frequency-dependent attenuation of the same size MBs in mediums with different charge densities. In-house lipid-coated MBs with C3F8 gas core were formulated. The MBs were isolated to a mean size of 2.35 μm using differential centrifugation. MBs were diluted to ≈8×105 MBs/mL in distilled water (DW), Phosphate-Buffered Saline solution (PBS1x) and PBS10x. The frequency-dependent attenuation of the MBs solutions was measured using an aligned pair of PVDF transducers with a center frequency of 10MHz and 100% bandwidth in the linear oscillation regime (7 kPa pressure amplitude). The MB shell properties were estimated by fitting the linear equation to experiments. Using a pendant drop tension meter, the surface tension at the equilibrium of ≈6 mm diameter size drops of the same MB shell was measured inside DW, PBS1x and PBS10x. The surface tension at the C3F8/solution interface was estimated by fitting the Young-Laplace equation from the recorded images. The frequency of the peak attenuation at different salinity levels was 13, 7.5 and 6.25 MHz in DW, PBS1x and PBS-10x, respectively. The attenuation peak increased by ≈140% with increasing ion density. MBs' estimated shell elasticity decreased by 64% between DW and PBS-1x and 36% between PBS-1x and PBS-10x. The drop surface tension reduced by 10.5% between DW and PBS-1x and by 5% between PBS-1x and PBS-10x, respectively. Reduction in the shell stiffness is consistent with the drop surface tension measurements. The shell viscosity was reduced by ≈40% between DW and PBS-1x and 42% between PBS-1x and PBS-10x. The reduction in the fitted stiffness and viscosity is possibly due to the formation of a densely charged layer around the shell, further reducing the effective surface tension on the MBs. The changes in the resonance frequency and estimated shell parameters were significant and may potentially help to better understand and explain bubble behavior in applications.
Collapse
Affiliation(s)
- A J Sojahrood
- Sunnybrook Research Institute, Toronto, Ontario, Canada; Department of Physics, Toronto Metropolitan University, Toronto, Canada; Institute for Biomedical Engineering, Science and Technology (IBEST), a partnership between Toronto Metropolitan University and St. Michael's Hospital, Toronto, Ontario, Canada.
| | - C Yang
- Department of Physics, Toronto Metropolitan University, Toronto, Canada; Institute for Biomedical Engineering, Science and Technology (IBEST), a partnership between Toronto Metropolitan University and St. Michael's Hospital, Toronto, Ontario, Canada
| | - C Counil
- Department of Biomedical Engineering, Case Western University, Cleveland, OH, USA
| | - P Nittayacharn
- Department of Biomedical Engineering, Case Western University, Cleveland, OH, USA; Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Puttamonthon, Nakorn Pathom, Thailand
| | - D E Goertz
- Sunnybrook Research Institute, Toronto, Ontario, Canada; Department of Medical Biophysics, University of Toronto, Ontario, Canada
| | - A A Exner
- Department of Biomedical Engineering, Case Western University, Cleveland, OH, USA
| | - M C Kolios
- Department of Physics, Toronto Metropolitan University, Toronto, Canada; Institute for Biomedical Engineering, Science and Technology (IBEST), a partnership between Toronto Metropolitan University and St. Michael's Hospital, Toronto, Ontario, Canada
| |
Collapse
|
4
|
van Haren MHI, Visser BS, Spruijt E. Probing the surface charge of condensates using microelectrophoresis. Nat Commun 2024; 15:3564. [PMID: 38670952 PMCID: PMC11053090 DOI: 10.1038/s41467-024-47885-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Accepted: 04/16/2024] [Indexed: 04/28/2024] Open
Abstract
Biomolecular condensates play an important role in cellular organization. Coacervates are commonly used models that mimic the physicochemical properties of biomolecular condensates. The surface of condensates plays a key role in governing molecular exchange between condensates, accumulation of species at the interface, and the stability of condensates against coalescence. However, most important surface properties, including the surface charge and zeta potential, remain poorly characterized and understood. The zeta potential of coacervates is often measured using laser doppler electrophoresis, which assumes a size-independent electrophoretic mobility. Here, we show that this assumption is incorrect for liquid-like condensates and present an alternative method to study the electrophoretic mobility of coacervates and in vitro condensate models by microelectrophoresis and single-particle tracking. Coacervates have a size-dependent electrophoretic mobility, originating from their fluid nature, from which a well-defined zeta potential is calculated. Interestingly, microelectrophoresis measurements reveal that polylysine chains are enriched at the surface of polylysine/polyaspartic acid complex coacervates, which causes the negatively charged protein ɑ-synuclein to adsorb and accumulate at the interface. Addition of ATP inverts the surface charge, displaces ɑ-synuclein from the surface and may help to suppress its interface-catalyzed aggregation. Together, these findings show how condensate surface charge can be measured and altered, making this microelectrophoresis platform combined with automated single-particle tracking a promising characterization technique for both biomolecular condensates and coacervate protocells.
Collapse
Affiliation(s)
- Merlijn H I van Haren
- Institute for Molecules and Materials, Radboud University, Heyendaalseweg 135, 6523, AJ, Nijmegen, The Netherlands
| | - Brent S Visser
- Institute for Molecules and Materials, Radboud University, Heyendaalseweg 135, 6523, AJ, Nijmegen, The Netherlands
| | - Evan Spruijt
- Institute for Molecules and Materials, Radboud University, Heyendaalseweg 135, 6523, AJ, Nijmegen, The Netherlands.
| |
Collapse
|
5
|
Polydorou AE, May JP, Makris K, Ferri S, Wu Q, Stride E, Carugo D, Evans ND. An investigation into the cytotoxic effects of microbubbles and their constituents on osteosarcoma and bone marrow stromal cells. Biochim Biophys Acta Gen Subj 2023; 1867:130481. [PMID: 37802372 DOI: 10.1016/j.bbagen.2023.130481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 09/26/2023] [Accepted: 10/02/2023] [Indexed: 10/10/2023]
Abstract
BACKGROUND Ultrasound-responsive microbubbles offer a means of achieving minimally invasive, localised drug delivery in applications including regenerative medicine. To facilitate their use, however, it is important to determine any cytotoxic effects they or their constituents may have. The aim of this study was to test the hypothesis that phospholipid-shelled microbubbles are non-toxic to human bone-derived cells at biologically-relevant concentrations. METHODS Microbubbles were fabricated using combinations of 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC), 1,2-dibehenoyl-sn-glycero-3-phosphocholine (DBPC), polyoxyethylene(40) stearate (PEG40S) and 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-[methoxy(polyethylene-glycol)-2000] (DSPE-PEG2000). Microbubble size and concentration were measured as a function of time and temperature by optical microscopy. Effects on MG63 osteosarcoma and human bone marrow stromal cells (BMSCs) were measured for up to 72 h by assay for viability, metabolic activity and proliferation. RESULTS DBPC:DSPE-PEG2000 microbubbles were significantly more stable than DSPC:PEG40S microbubbles under all conditions tested. Serum-containing medium had no detrimental effect on microbubble stability, but storage at 37 °C compared to at 4 °C reduced stability for both preparations, with almost complete dissolution of microbubbles at times ≥24 h. DSPC:PEG40S microbubbles had greater inhibitory effects on cell metabolism and growth than DBPC:DSPE-PEG2000 microbubbles, with PEG40S found to be the principle inhibitory component. These effects were only evident at high microbubble concentrations (≥20% (v/v)) or with prolonged culture (≥24 h). Increasing cell-microbubble contact by inversion culture in a custom-built device had no inhibitory effect on metabolism. CONCLUSIONS These data indicate that, over a broad range of concentrations and incubation times, DBPC:DSPE-PEG2000 and DSPC:PEG40S microbubbles have little effect on osteoblastic cell viability and growth, and that PEG40S is the principle inhibitory component in the formulations investigated.
Collapse
Affiliation(s)
- A E Polydorou
- Centre for Human Development, Stem Cells and Regenerative Medicine, Bone and Joint Research group, University of Southampton, United Kingdom; Bioengineering Sciences Group, Institute for Life Sciences, University of Southampton, United Kingdom
| | - J P May
- Centre for Human Development, Stem Cells and Regenerative Medicine, Bone and Joint Research group, University of Southampton, United Kingdom; Bioengineering Sciences Group, Institute for Life Sciences, University of Southampton, United Kingdom
| | - K Makris
- Bioengineering Sciences Group, Institute for Life Sciences, University of Southampton, United Kingdom
| | - S Ferri
- Centre for Human Development, Stem Cells and Regenerative Medicine, Bone and Joint Research group, University of Southampton, United Kingdom; Bioengineering Sciences Group, Institute for Life Sciences, University of Southampton, United Kingdom
| | - Q Wu
- Institute of Biomedical Engineering, University of Oxford, United Kingdom
| | - E Stride
- Institute of Biomedical Engineering, University of Oxford, United Kingdom; Botnar Research Centre, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, United Kingdom
| | - D Carugo
- Botnar Research Centre, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, United Kingdom
| | - N D Evans
- Centre for Human Development, Stem Cells and Regenerative Medicine, Bone and Joint Research group, University of Southampton, United Kingdom; Bioengineering Sciences Group, Institute for Life Sciences, University of Southampton, United Kingdom.
| |
Collapse
|
6
|
Navarro-Becerra JA, Borden MA. Targeted Microbubbles for Drug, Gene, and Cell Delivery in Therapy and Immunotherapy. Pharmaceutics 2023; 15:1625. [PMID: 37376072 DOI: 10.3390/pharmaceutics15061625] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/18/2023] [Accepted: 05/26/2023] [Indexed: 06/29/2023] Open
Abstract
Microbubbles are 1-10 μm diameter gas-filled acoustically-active particles, typically stabilized by a phospholipid monolayer shell. Microbubbles can be engineered through bioconjugation of a ligand, drug and/or cell. Since their inception a few decades ago, several targeted microbubble (tMB) formulations have been developed as ultrasound imaging probes and ultrasound-responsive carriers to promote the local delivery and uptake of a wide variety of drugs, genes, and cells in different therapeutic applications. The aim of this review is to summarize the state-of-the-art of current tMB formulations and their ultrasound-targeted delivery applications. We provide an overview of different carriers used to increase drug loading capacity and different targeting strategies that can be used to enhance local delivery, potentiate therapeutic efficacy, and minimize side effects. Additionally, future directions are proposed to improve the tMB performance in diagnostic and therapeutic applications.
Collapse
Affiliation(s)
| | - Mark A Borden
- Mechanical Engineering Department, University of Colorado Boulder, Boulder, CO 80309, USA
- Biomedical Engineering Program, University of Colorado Boulder, Boulder, CO 80309, USA
| |
Collapse
|
7
|
Toma I, Porfire AS, Tefas LR, Berindan-Neagoe I, Tomuță I. A Quality by Design Approach in Pharmaceutical Development of Non-Viral Vectors with a Focus on miRNA. Pharmaceutics 2022; 14:1482. [PMID: 35890377 PMCID: PMC9322860 DOI: 10.3390/pharmaceutics14071482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 06/28/2022] [Accepted: 07/14/2022] [Indexed: 12/10/2022] Open
Abstract
Cancer is the leading cause of death worldwide. Tumors consist of heterogeneous cell populations that have different biological properties. While conventional cancer therapy such as chemotherapy, radiotherapy, and surgery does not target cancer cells specifically, gene therapy is attracting increasing attention as an alternative capable of overcoming these limitations. With the advent of gene therapy, there is increasing interest in developing non-viral vectors for genetic material delivery in cancer therapy. Nanosystems, both organic and inorganic, are the most common non-viral vectors used in gene therapy. The most used organic vectors are polymeric and lipid-based delivery systems. These nanostructures are designed to bind and protect the genetic material, leading to high efficiency, prolonged gene expression, and low toxicity. Quality by Design (QbD) is a step-by-step approach that investigates all the factors that may affect the quality of the final product, leading to efficient pharmaceutical development. This paper aims to provide a new perspective regarding the use of the QbD approach for improving the quality of non-viral vectors for genetic material delivery and their application in cancer therapy.
Collapse
Affiliation(s)
- Ioana Toma
- Department of Pharmaceutical Technology and Biopharmacy, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania; (I.T.); (L.R.T.); (I.T.)
| | - Alina Silvia Porfire
- Department of Pharmaceutical Technology and Biopharmacy, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania; (I.T.); (L.R.T.); (I.T.)
| | - Lucia Ruxandra Tefas
- Department of Pharmaceutical Technology and Biopharmacy, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania; (I.T.); (L.R.T.); (I.T.)
| | - Ioana Berindan-Neagoe
- Research Center for Functional Genomics Biomedicine and Translational Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, 400337 Cluj-Napoca, Romania;
| | - Ioan Tomuță
- Department of Pharmaceutical Technology and Biopharmacy, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania; (I.T.); (L.R.T.); (I.T.)
| |
Collapse
|
8
|
Li J, Zhang Y, Zou C, Chen Y, Li Y, Chen H. Binding properties of flowing fibrin-targeted microbubbles evaluated with a thrombus-embedded microchannel. LAB ON A CHIP 2022; 22:2292-2298. [PMID: 35616180 DOI: 10.1039/d1lc01037a] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Fibrin is found in both arterial and venous thrombi, which provides an important target for thrombus-targeted microbubbles (MBs) used in MB-enhanced ultrasound imaging and sonothrombolysis. A fibrin-targeted peptide, Cys-Arg-Glu-Lys-Ala (CREKA), is used to modify the commercially available SonoVue ultrasound contrast agent using a conjugation method, and the binding capacity and binding strength of the fibrin-targeted CREKA-modified SonoVue MBs are evaluated with a thrombus-embedded microchannel at a typical shear rate range of venous and arterial blood flow. The experimental results indicate that the targeted MBs bind firmly to the thrombus surface when they flow along the microchannel at a wall shear rate of up to 1000 s-1. This work not only provides an effective method for the fabrication of fibrin-targeted MBs based on commercially available SonoVue MBs but also demonstrates an approach for evaluation of the binding properties of flowing targeted MBs under well-controlled flow conditions.
Collapse
Affiliation(s)
- Jiang Li
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Yuan Zhang
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Chenghong Zou
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Yuexin Chen
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Yongjian Li
- State Key Laboratory of Tribology, Tsinghua University, Beijing 100084, China.
| | - Haosheng Chen
- State Key Laboratory of Tribology, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
9
|
Kotopoulis S, Lam C, Haugse R, Snipstad S, Murvold E, Jouleh T, Berg S, Hansen R, Popa M, Mc Cormack E, Gilja OH, Poortinga A. Formulation and characterisation of drug-loaded antibubbles for image-guided and ultrasound-triggered drug delivery. ULTRASONICS SONOCHEMISTRY 2022; 85:105986. [PMID: 35358937 PMCID: PMC8967728 DOI: 10.1016/j.ultsonch.2022.105986] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 03/14/2022] [Accepted: 03/21/2022] [Indexed: 06/13/2023]
Abstract
The aim of this study was to develop high load-capacity antibubbles that can be visualized using diagnostic ultrasound and the encapsulated drug can be released and delivered using clinically translatable ultrasound. The antibubbles were developed by optimising a silica nanoparticle stabilised double emulsion template. We produced an emulsion with a mean size diameter of 4.23 ± 1.63 µm where 38.9 ± 3.1% of the droplets contained a one or more cores. Following conversion to antibubbles, the mean size decreased to 2.96 ± 1.94 µm where 99% of antibubbles were <10 µm. The antibubbles had a peak attenuation of 4.8 dB/cm at 3.0 MHz at a concentration of 200 × 103 particles/mL and showed distinct attenuation spikes at frequencies between 5.5 and 13.5 MHz. No increase in subharmonic response was observed for the antibubbles in contrast to SonoVue®. High-speed imaging revealed that antibubbles can release their cores at MIs of 0.6. In vivo imaging indicated that the antibubbles have a long half-life of 68.49 s vs. 40.02 s for SonoVue®. The antibubbles could be visualised using diagnostic ultrasound and could be disrupted at MIs of ≥0.6. The in vitro drug delivery results showed that antibubbles can significantly improve drug delivery (p < 0.0001) and deliver the drug within the antibubbles. In conclusion antibubbles are a viable concept for ultrasound guided drug delivery.
Collapse
Affiliation(s)
- Spiros Kotopoulis
- Department of Clinical Medicine, University of Bergen, Bergen, Norway; National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway; Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway; Neoety AS, Kløfta, Norway.
| | - Christina Lam
- Department of Clinical Science, University of Bergen, Bergen, Norway
| | - Ragnhild Haugse
- Department of Clinical Science, University of Bergen, Bergen, Norway; Department of Quality and Development, Hospital Pharmacies Enterprise in Western Norway, Bergen, Norway
| | - Sofie Snipstad
- Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway; Department of Biotechnology and Nanomedicine, SINTEF Industry, Trondheim, Norway; Cancer Clinic, St. Olav's Hospital, Trondheim, Norway
| | - Elisa Murvold
- Department of Clinical Medicine, University of Bergen, Bergen, Norway; National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway; KinN Therapeutics, Bergen, Norway
| | - Tæraneh Jouleh
- Department of Clinical Medicine, University of Bergen, Bergen, Norway; National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
| | - Sigrid Berg
- Department of Biotechnology and Nanomedicine, SINTEF Industry, Trondheim, Norway
| | - Rune Hansen
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway; Department of Health Research, SINTEF Digital, Trondheim, Norway
| | - Mihaela Popa
- Department of Clinical Science, University of Bergen, Bergen, Norway; CCBIO, Department of Clinical Science, University of Bergen, Norway
| | - Emmet Mc Cormack
- Department of Clinical Science, University of Bergen, Bergen, Norway; KinN Therapeutics, Bergen, Norway
| | - Odd Helge Gilja
- Department of Clinical Medicine, University of Bergen, Bergen, Norway; National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
| | - Albert Poortinga
- Polymer Technology, Eindhoven University of Technology, Eindhoven, the Netherlands
| |
Collapse
|
10
|
Zhou S, Nazari S, Hassanzadeh A, Bu X, Ni C, Peng Y, Xie G, He Y. The effect of preparation time and aeration rate on the properties of bulk micro-nanobubble water using hydrodynamic cavitation. ULTRASONICS SONOCHEMISTRY 2022; 84:105965. [PMID: 35240410 PMCID: PMC8889407 DOI: 10.1016/j.ultsonch.2022.105965] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 02/10/2022] [Accepted: 02/23/2022] [Indexed: 05/11/2023]
Abstract
Fundamental research on bulk micro-nanobubbles (BMNBs) has grown rapidly due to the demand for their industrial applications and potential role in interfacial sciences. This work focuses on examining properties of such bubbles, including the number, concentration, zeta potential, and surface tension in water. For this purpose, BMNBs were generated by the hydrodynamic cavitation (HC) mechanism. Distilled water and air in the experiments were the liquid and gas phases, respectively. The characterization of bulk microbubbles (BMBs) and bulk nanobubbles (BNBs) were performed through focused beam reflectance measurement (FBRM) and nanoparticle tracking analysis (NTA) techniques, respectively. Zeta potential and surface tension of aqueous solutions were measured at different time and aeration rates. The results showed that aeration rate and preparation time had an important role in the properties of BNBs (concentration, bubble size, and surface charge) and BMBs (number, and bubble size). The instability of BMBs led to the rapid changes in the dissolved oxygen (DO) content in the water. The number of BMBs decreased when preparation time and aeration rate increased, but their size remained constant. By enhancing the preparation time and aeration rate, the concentration of BNBs improved first and then reduced. Additionally, the surface tension of an aqueous solution containing BNBs was significantly lower than that of pure water.
Collapse
Affiliation(s)
- Shaoqi Zhou
- Key Laboratory of Coal Processing and Efficient Utilization (Ministry of Education), China University of Mining and Technology, Xuzhou 221116, China; School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou 221116, China
| | - Sabereh Nazari
- School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou 221116, China
| | - Ahmad Hassanzadeh
- Maelgwyn Mineral Services Ltd, Ty Maelgwyn, 1A Gower Road, Cathays, Cardiff CF24 4PA, United Kingdom; Department of Geoscience and Petroleum, Faculty of Engineering, Norwegian University of Science and Technology, Trondheim, Norway
| | - Xiangning Bu
- Key Laboratory of Coal Processing and Efficient Utilization (Ministry of Education), China University of Mining and Technology, Xuzhou 221116, China; School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou 221116, China.
| | - Chao Ni
- Key Laboratory of Coal Processing and Efficient Utilization (Ministry of Education), China University of Mining and Technology, Xuzhou 221116, China; School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou 221116, China
| | - Yaoli Peng
- Key Laboratory of Coal Processing and Efficient Utilization (Ministry of Education), China University of Mining and Technology, Xuzhou 221116, China; School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou 221116, China
| | - Guangyuan Xie
- Key Laboratory of Coal Processing and Efficient Utilization (Ministry of Education), China University of Mining and Technology, Xuzhou 221116, China; School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou 221116, China
| | - Yaqun He
- School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou 221116, China
| |
Collapse
|
11
|
Nanomaterials as Ultrasound Theragnostic Tools for Heart Disease Treatment/Diagnosis. Int J Mol Sci 2022; 23:ijms23031683. [PMID: 35163604 PMCID: PMC8835969 DOI: 10.3390/ijms23031683] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 01/25/2022] [Accepted: 01/26/2022] [Indexed: 01/27/2023] Open
Abstract
A variety of different nanomaterials (NMs) such as microbubbles (MBs), nanobubbles (NBs), nanodroplets (NDs), and silica hollow meso-structures have been tested as ultrasound contrast agents for the detection of heart diseases. The inner part of these NMs is made gaseous to yield an ultrasound contrast, which arises from the difference in acoustic impedance between the interior and exterior of such a structure. Furthermore, to specifically achieve a contrast in the diseased heart region (DHR), NMs can be designed to target this region in essentially three different ways (i.e., passively when NMs are small enough to diffuse through the holes of the vessels supplying the DHR, actively by being associated with a ligand that recognizes a receptor of the DHR, or magnetically by applying a magnetic field orientated in the direction of the DHR on a NM responding to such stimulus). The localization and resolution of ultrasound imaging can be further improved by applying ultrasounds in the DHR, by increasing the ultrasound frequency, or by using harmonic, sub-harmonic, or super-resolution imaging. Local imaging can be achieved with other non-gaseous NMs of metallic composition (i.e., essentially made of Au) by using photoacoustic imaging, thus widening the range of NMs usable for cardiac applications. These contrast agents may also have a therapeutic efficacy by carrying/activating/releasing a heart disease drug, by triggering ultrasound targeted microbubble destruction or enhanced cavitation in the DHR, for example, resulting in thrombolysis or helping to prevent heart transplant rejection.
Collapse
|
12
|
Schoen S, Kilinc MS, Lee H, Guo Y, Degertekin FL, Woodworth GF, Arvanitis C. Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound. Adv Drug Deliv Rev 2022; 180:114043. [PMID: 34801617 PMCID: PMC8724442 DOI: 10.1016/j.addr.2021.114043] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 09/27/2021] [Accepted: 11/04/2021] [Indexed: 02/06/2023]
Abstract
Brain tumors are particularly challenging malignancies, due to their location in a structurally and functionally distinct part of the human body - the central nervous system (CNS). The CNS is separated and protected by a unique system of brain and blood vessel cells which together prevent most bloodborne therapeutics from entering the brain tumor microenvironment (TME). Recently, great strides have been made through microbubble (MB) ultrasound contrast agents in conjunction with ultrasound energy to locally increase the permeability of brain vessels and modulate the brain TME. As we elaborate in this review, this physical method can effectively deliver a wide range of anticancer agents, including chemotherapeutics, antibodies, and nanoparticle drug conjugates across a range of preclinical brain tumors, including high grade glioma (glioblastoma), diffuse intrinsic pontine gliomas, and brain metastasis. Moreover, recent evidence suggests that this technology can promote the effective delivery of novel immunotherapeutic agents, including immune check-point inhibitors and chimeric antigen receptor T cells, among others. With early clinical studies demonstrating safety, and several Phase I/II trials testing the preclinical findings underway, this technology is making firm steps towards shaping the future treatments of primary and metastatic brain cancer. By elaborating on its key components, including ultrasound systems and MB technology, along with methods for closed-loop spatial and temporal control of MB activity, we highlight how this technology can be tuned to enable new, personalized treatment strategies for primary brain malignancies and brain metastases.
Collapse
Affiliation(s)
- Scott Schoen
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - M. Sait Kilinc
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Hohyun Lee
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Yutong Guo
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - F. Levent Degertekin
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Graeme F. Woodworth
- Department of Neurosurgery, University of Maryland School of Medicine, Baltimore, MD 21201, USA,Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, College Park, MD 20742, USA,Fischell Department of Bioengineering A. James Clarke School of Engineering, University of Maryland
| | - Costas Arvanitis
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA,Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
| |
Collapse
|
13
|
AlSadiq H, Tupally KR, Vogel R, Parekh HS, Veidt M. Multi-physics study of acoustofluidic delivery agents' clustering behavior. Phys Med Biol 2021; 67. [PMID: 34952530 DOI: 10.1088/1361-6560/ac4666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 12/24/2021] [Indexed: 11/12/2022]
Abstract
Acoustofluidicly manipulated microbubbles (MBs) and echogenic liposomes (ELIPs) have been suggested as drug delivery systems for the 'on demand' release of drug in target tissue. This requires a clear understanding of their behaviour during ultrasonication and after ultrasonication stops. The main focus of this study is to investigate the behaviour of MBs and ELIPs clusters after ultrasonication stops and the underlaying cause of cluster diffusion considering electrostatic repulsion, steric repulsion and Brownian motion. It also examines the capability of existing models used to predict MBs' attraction velocity due to secondary radiation force, on predicting ELIPs' attraction velocity. Tunable resistive pulse sensing (TRPS) and phase analysis light scattering (PALS) techniques were used to measure zeta potentials of the agents and the size distributions were measured using TRPS. The zeta potentials were found to be -2.43 mV and -0.62 mV for Definity™ MBs, and -3.62 mV and -2.35 mV for ELIPs using TRPS and PALS, respectively. Both agents were shown to have significant cluster formation at pressures as low as 6 kPa. Clusters of both agents were shown to diffuse as sonication stops at a rate that approximately equals the sum of the diffusion coefficients of the agents forming them. The de-clustering behaviours are due to Brownian motion as no sign of electrostatic repulsion was observed and particles movements were observed to be faster for smaller diameters. These findings are important to design and optimise effective drug delivery systems using acoustofluidically manipulated MBs and ELIPs.
Collapse
Affiliation(s)
- Hussain AlSadiq
- School of Mechanical and Mining Engineering, The University of Queensland, Saint Lucia, AUSTRALIA
| | - Karnaker Reddy Tupally
- school of Pharmacy , The University of Queensland, Saint Lucia, Queensland, 4072, AUSTRALIA
| | - Robert Vogel
- The University of Queensland, School of Mathematics and Physics, Saint Lucia, Queensland, 4067, AUSTRALIA
| | - Harendra S Parekh
- The University of Queensland, School of Pharmacy, Saint Lucia, Queensland, 4102, AUSTRALIA
| | - Martin Veidt
- School of Mechanical and Mining Engineering, University of Queensland, Brisbane, Queensland, AUSTRALIA
| |
Collapse
|
14
|
Yang Y, Pacia CP, Ye D, Yue Y, Chien CY, Chen H. Static Magnetic Fields Dampen Focused Ultrasound-mediated Blood-Brain Barrier Opening. Radiology 2021; 300:681-689. [PMID: 34227880 DOI: 10.1148/radiol.2021204441] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background Focused ultrasound combined with microbubbles has been used in clinical studies for blood-brain barrier (BBB) opening in conjunction with MRI. However, the impact of the static magnetic field generated by an MRI scanner on the BBB opening outcome has not been evaluated. Purpose To determine the relationship of the static magnetic field of an MRI scanner on focused ultrasound combined with microbubble-induced BBB opening. Materials and Methods Thirty wild-type mice were divided into four groups. Mice from different groups were sonicated with focused ultrasound in different static magnetic fields (approximately 0, 1.5, 3.0, and 4.7 T), with all other experimental parameters kept the same. Focused ultrasound sonication was performed after intravenous injection of microbubbles. Microbubble cavitation activity, the fundamental -physical mechanism underlying focused ultrasound BBB opening, was monitored with passive cavitation detection. After sonication, contrast-enhanced T1-weighted MRI was performed to assess BBB opening outcome. Intravenously injected Evans blue was used as a model agent to evaluate trans-BBB delivery efficiency. Results The microbubble cavitation dose decreased by an average of 2.1 dB at 1.5 T (P = .05), 2.9 dB at 3.0 T (P = .01), and 3.0 dB at 4.7 T (P = .01) compared with that outside the magnetic field (approximately 0 T). The static magnetic field of an MRI scanner decreased BBB opening volume in mice by 3.2-fold at 1.5 T (P < .001), 4.5-fold at 3.0 T (P < .001), and 11.6-fold at 4.7 T (P <.001) compared with mice treated outside the magnetic field. It also decreased Evans blue trans-BBB delivery 1.4-fold at 1.5 T (P = .009), 1.6-fold at 3.0 T (P < .001), and 1.9-fold at 4.7 T (P < .001). Conclusion Static magnetic fields dampened microbubble cavitation activity and decreased trans-blood-brain barrier (BBB) delivery by focused ultrasound combined with microbubble-induced BBB opening. © RSNA, 2021 An earlier incorrect version of this article appeared online. This article was corrected on July 8, 2021.
Collapse
Affiliation(s)
- Yaoheng Yang
- From the Departments of Biomedical Engineering (Y. Yang, C.P.P., D.Y., Y. Yue, C.Y.C., H.C.) and Radiation Oncology (H.C.), Washington University in St Louis, 4511 Forest Park Ave, St Louis, MO 63108
| | - Christopher Pham Pacia
- From the Departments of Biomedical Engineering (Y. Yang, C.P.P., D.Y., Y. Yue, C.Y.C., H.C.) and Radiation Oncology (H.C.), Washington University in St Louis, 4511 Forest Park Ave, St Louis, MO 63108
| | - Dezhuang Ye
- From the Departments of Biomedical Engineering (Y. Yang, C.P.P., D.Y., Y. Yue, C.Y.C., H.C.) and Radiation Oncology (H.C.), Washington University in St Louis, 4511 Forest Park Ave, St Louis, MO 63108
| | - Yimei Yue
- From the Departments of Biomedical Engineering (Y. Yang, C.P.P., D.Y., Y. Yue, C.Y.C., H.C.) and Radiation Oncology (H.C.), Washington University in St Louis, 4511 Forest Park Ave, St Louis, MO 63108
| | - Chih-Yen Chien
- From the Departments of Biomedical Engineering (Y. Yang, C.P.P., D.Y., Y. Yue, C.Y.C., H.C.) and Radiation Oncology (H.C.), Washington University in St Louis, 4511 Forest Park Ave, St Louis, MO 63108
| | - Hong Chen
- From the Departments of Biomedical Engineering (Y. Yang, C.P.P., D.Y., Y. Yue, C.Y.C., H.C.) and Radiation Oncology (H.C.), Washington University in St Louis, 4511 Forest Park Ave, St Louis, MO 63108
| |
Collapse
|
15
|
Ultrasound Microbubbles Enhance the Efficacy of Insulin-Like Growth Factor-1 Therapy for the Treatment of Noise-Induced Hearing Loss. Molecules 2021; 26:molecules26123626. [PMID: 34199327 PMCID: PMC8231984 DOI: 10.3390/molecules26123626] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 06/02/2021] [Accepted: 06/11/2021] [Indexed: 11/17/2022] Open
Abstract
The application of insulin-like growth factor 1 (IGF-1) to the round window membrane (RWM) is an emerging treatment for inner ear diseases. RWM permeability is the key factor for efficient IGF-1 delivery. Ultrasound microbubbles (USMBs) can increase drug permeation through the RWM. In the present study, the enhancing effect of USMBs on the efficacy of IGF-1 application and the treatment effect of USMB-mediated IGF-1 delivery for noise-induced hearing loss (NIHL) were investigated. Forty-seven guinea pigs were assigned to three groups: the USM group, which received local application of recombinant human IGF-1 (rhIGF-1, 10 µg/µL) following application of USMBs to the RWM; the RWS group, which received IGF-1 application alone; and the saline-treated group. The perilymphatic concentration of rhIGF-1 in the USM group was 1.95- and 1.67- fold of that in the RWS group, 2 and 24 h after treatment, respectively. After 5 h of 118 dB SPL noise exposure, the USM group had the lowest threshold shift in auditory brainstem response, least loss of cochlear outer hair cells, and least reduction in the number of synaptic ribbons on postexposure day 28 among the three groups. The combination of USMB and IGF-1 led to a better therapeutic response to NIHL. Two hours after treatment, the USM group had significantly higher levels of Akt1 and Mapk3 gene expression than the other two groups. The most intense immunostaining for phosphor-AKT and phospho-ERK1/2 was detected in the cochlea in the USM group. These results suggested that USMB can be applied to enhance the efficacy of IGF-1 therapy in the treatment of inner ear diseases.
Collapse
|
16
|
Wei S, Xu C, Zhang Y, Shi Z, Wu M, Yang B. Ultrasound Assisted a Peroxisome Proliferator-Activated Receptor (PPAR)γ Agonist-Loaded Nanoparticle-Microbubble Complex to Attenuate Renal Interstitial Fibrosis. Int J Nanomedicine 2020; 15:7315-7327. [PMID: 33061383 PMCID: PMC7537998 DOI: 10.2147/ijn.s262052] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Accepted: 09/15/2020] [Indexed: 12/25/2022] Open
Abstract
Objective To investigate the antifibrotic effect of the combination of a PPARγ agonist-loaded nanoparticle-microbubble complex with ultrasound (US) exposure on renal interstitial fibrosis (RIF). Materials and Methods Polylactide-co-glycolide (PLGA) nanoparticles were used to load PPARγ agonist (rosiglitazone, RSG) and prepare PLGA-RSG nanoparticles (PLNPs-RSG); then, a novel complex between PLNPs-RSG and SonoVue microbubbles (MBs) (PLNPs-RSG-MBs) was prepared. The size distribution, zeta potentials, RSG-loading capacity and entrapment efficiency were measured, and the release of RSG was assessed using a UV-vis spectrophotometer. The in vitro cytotoxicity and in vivo systemic toxicity assays were performed. The cellular uptake assessment was performed using a confocal laser scanning microscope (CLSM). The in vivo biodistribution assessment was performed using fluorescence imaging with a near-infrared (NIR) imaging system. Furthermore, this complex was administered to a unilateral ureteral obstruction (UUO) rat model with the assistance of US exposure to investigate the antifibrotic effect. Results This PLNPs-RSG-MBs complex had a size of 2199.5± 988.1 nm and a drug-loading efficiency of 28.5%. In vitro cytotoxicity and in vivo systemic toxicity assays indicated that the PLNPs-RSG-MBs complex displayed excellent biocompatibility. In addition, the complex showed high cellular uptake efficiency in vitro and kidney-targeting ability in vivo. In a UUO rat model, the combination of the PLNPs-RSG-MBs complex with US exposure significantly reduced collagen deposition and successfully attenuated renal fibrosis. Conclusion The combination of the PLNPs-RSG-MBs complex with US exposure may be a promising approach for the treatment of RIF.
Collapse
Affiliation(s)
- Shuping Wei
- Department of Ultrasound, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, Jiangsu, People's Republic of China
| | - Chaoli Xu
- Department of Ultrasound, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, People's Republic of China
| | - Yidan Zhang
- Department of Ultrasound, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, Jiangsu, People's Republic of China
| | - Zhongqing Shi
- Department of Cardiac Function, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, Jiangsu, People's Republic of China
| | - Min Wu
- Department of Ultrasound, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, Jiangsu, People's Republic of China
| | - Bin Yang
- Department of Ultrasound, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, People's Republic of China
| |
Collapse
|
17
|
Al-Jawadi S, Thakur SS. Ultrasound-responsive lipid microbubbles for drug delivery: A review of preparation techniques to optimise formulation size, stability and drug loading. Int J Pharm 2020; 585:119559. [PMID: 32574685 DOI: 10.1016/j.ijpharm.2020.119559] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 06/14/2020] [Accepted: 06/15/2020] [Indexed: 02/08/2023]
Abstract
Lipid-shelled microbubbles have received extensive interest to enhance ultrasound-responsive drug delivery outcomes due to their high biocompatibility. While therapeutic effectiveness of microbubbles is well established, there remain limitations in sample homogeneity, stability profile and drug loading properties which restrict these formulations from seeing widespread use in the clinical setting. In this review, we evaluate and discuss the most encouraging leads in lipid microbubble design and optimisation. We examine current applications in drug delivery for the systems and subsequently detail shell compositions and preparation strategies that improve monodispersity while retaining ultrasound responsiveness. We review how excipients and storage techniques help maximise stability and introduce different characterisation and drug loading techniques and evaluate their impact on formulation performance. The review concludes with current quality control measures in place to ensure lipid microbubbles can be reproducibly used in drug delivery.
Collapse
Affiliation(s)
- Sana Al-Jawadi
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Sachin S Thakur
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand.
| |
Collapse
|
18
|
Bjånes T, Kotopoulis S, Murvold ET, Kamčeva T, Gjertsen BT, Gilja OH, Schjøtt J, Riedel B, McCormack E. Ultrasound- and Microbubble-Assisted Gemcitabine Delivery to Pancreatic Cancer Cells. Pharmaceutics 2020; 12:pharmaceutics12020141. [PMID: 32046005 PMCID: PMC7076495 DOI: 10.3390/pharmaceutics12020141] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 01/28/2020] [Accepted: 02/04/2020] [Indexed: 02/06/2023] Open
Abstract
Pancreatic ductal adenocarcinoma (PDAC) is a major cause of cancer death worldwide. Poor drug delivery to tumours is thought to limit chemotherapeutic treatment efficacy. Sonoporation combines ultrasound (US) and microbubbles to increase the permeability of cell membranes. We assessed gemcitabine uptake combined with sonoporation in vitro in three PDAC cell lines (BxPC-3, MIA PaCa-2 and PANC-1). Cells were cultured in hypoxic bioreactors, while gemcitabine incubation ± sonoporation was conducted in cells with operational or inhibited nucleoside membrane transporters. Intracellular active metabolite (dFdCTP), extracellular gemcitabine, and inactive metabolite (dFdU) concentrations were measured with liquid chromatography tandem mass spectrometry. Sonoporation with increasing US intensities resulted in decreasing extracellular gemcitabine concentrations in all three cell lines with inhibited membrane transporters. In cells with inhibited membrane transporters, without sonoporation, dFdCTP concentrations were reduced down to 10% of baseline. Sonoporation partially restored gemcitabine uptake in these cells, as indicated by a moderate increase in dFdCTP concentrations (up to 37% of baseline) in MIA PaCa-2 and PANC-1. In BxPC-3, gemcitabine was effectively inactivated to dFdU, which might represent a protective mechanism against dFdCTP accumulation in these cells. Intracellular dFdCTP concentrations did not change significantly following sonoporation in any of the cell lines with operational membrane transporters, indicating that the gemcitabine activation pathway may have been saturated with the drug. Sonoporation allowed a moderate increase in gemcitabine transmembrane uptake in all three cell lines, but pre-existing nucleoside transporters were the major determinants of gemcitabine uptake and retention.
Collapse
Affiliation(s)
- Tormod Bjånes
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen 5021, Norway; (T.K.); (J.S.); (B.R.)
- Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen 5021, Norway;
- Correspondence: (T.B.); (E.M.)
| | - Spiros Kotopoulis
- Phoenix Solutions AS, Ullernchausseen 64, 0379 Oslo, Norway;
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen 5021, Norway;
- Department of Clinical Medicine, University of Bergen, Bergen 5021, Norway
| | | | - Tina Kamčeva
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen 5021, Norway; (T.K.); (J.S.); (B.R.)
| | - Bjørn Tore Gjertsen
- Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen 5021, Norway;
- Department of Internal Medicine, Hematology Section, Haukeland University Hospital, Bergen 5021, Norway
| | - Odd Helge Gilja
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen 5021, Norway;
- Department of Clinical Medicine, University of Bergen, Bergen 5021, Norway
| | - Jan Schjøtt
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen 5021, Norway; (T.K.); (J.S.); (B.R.)
- Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen 5021, Norway;
| | - Bettina Riedel
- Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen 5021, Norway; (T.K.); (J.S.); (B.R.)
- Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen 5021, Norway;
| | - Emmet McCormack
- Department of Clinical Science, Faculty of Medicine, University of Bergen, Bergen 5021, Norway;
- Centre for Cancer Biomarkers CCBIO, Department of Clinical Science, University of Bergen, Bergen 5021, Norway
- Correspondence: (T.B.); (E.M.)
| |
Collapse
|
19
|
Josefsson L, Goodall D, Emmer Å. Implementation of a ultraviolet area imaging detector for analysis of polyvinyl alcohol microbubbles by capillary electrophoresis. J Chromatogr A 2020; 1619:460899. [PMID: 31983415 DOI: 10.1016/j.chroma.2020.460899] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 01/13/2020] [Accepted: 01/17/2020] [Indexed: 11/19/2022]
Abstract
Contrast agents are widely used to enhance the image quality in clinical imaging using e.g. ultrasound. The contrast agents used for ultrasound imaging are mainly microbubbles (MBs) with a soft or hard shell encapsulating a core of gas. In the present study, MBs with a hard shell of polyvinyl alcohol (PVA), and a core of air were analysed in a capillary electrophoretic system using a UV area imaging detector. The detector was operating at 3 wavelengths; 214 nm, 255 nm and 525 nm, and the highest absorbance for individual PVA-MBs were obtained at 214 nm. Two detection windows and a vertical loop capillary position enabled tracking of the PVA-MBs both in an upward and a downward flow direction, where PVA-MBs had different flow distributions and slightly higher average flow velocity upwards, attributed to temperature differences in the capillary that was part within the instrument and part outside. The tracking also allowed counting and quantification of the PVA-MBs. Separation of PVA-MBs from proteins present in human blood plasma was achieved, with multi-wavelength imaging showing best contrast at 525 nm. The PVA-MBs absolute values of negative zeta potential and anionic mobility when injected from plasma in the pH 12 background electrolyte are higher than those obtained for MBs injected from buffer, consistent with their increased negative charge due to a protein corona coating of the PVA-MBs.
Collapse
Affiliation(s)
- Leila Josefsson
- Department of Chemistry, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Stockholm, Sweden.
| | | | - Åsa Emmer
- Department of Chemistry, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Stockholm, Sweden
| |
Collapse
|
20
|
Jamburidze A, Huerre A, Baresch D, Poulichet V, De Corato M, Garbin V. Nanoparticle-Coated Microbubbles for Combined Ultrasound Imaging and Drug Delivery. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:10087-10096. [PMID: 31033294 DOI: 10.1021/acs.langmuir.8b04008] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Biomedical microbubbles stabilized by a coating of magnetic or drug-containing nanoparticles show great potential for theranostics applications. Nanoparticle-coated microbubbles can be made to be stable, to be echogenic, and to release the cargo of drug-containing nanoparticles with an ultrasound trigger. This Article reviews the design principles of nanoparticle-coated microbubbles for ultrasound imaging and drug delivery, with a particular focus on the physical chemistry of nanoparticle-coated interfaces; the formation, stability, and dynamics of nanoparticle-coated bubbles; and the conditions for controlled nanoparticle release in ultrasound. The emerging understanding of the modes of nanoparticle expulsion and of the transport of expelled material by microbubble-induced flow is paving the way toward more efficient nanoparticle-mediated drug delivery. This Article highlights the knowledge gap that still remains to be addressed before we can control these phenomena.
Collapse
Affiliation(s)
- Akaki Jamburidze
- Department of Chemical Engineering , Imperial College London , London SW7 2AZ , United Kingdom
| | - Axel Huerre
- Department of Chemical Engineering , Imperial College London , London SW7 2AZ , United Kingdom
| | - Diego Baresch
- Department of Chemical Engineering , Imperial College London , London SW7 2AZ , United Kingdom
| | - Vincent Poulichet
- Department of Chemistry , Ecole Normale Superieure , 75005 Paris , France
| | - Marco De Corato
- Department of Chemical Engineering , Imperial College London , London SW7 2AZ , United Kingdom
| | - Valeria Garbin
- Department of Chemical Engineering , Imperial College London , London SW7 2AZ , United Kingdom
| |
Collapse
|
21
|
Borden MA, Song KH. Reverse engineering the ultrasound contrast agent. Adv Colloid Interface Sci 2018; 262:39-49. [PMID: 30396507 PMCID: PMC6268001 DOI: 10.1016/j.cis.2018.10.004] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Revised: 10/09/2018] [Accepted: 10/22/2018] [Indexed: 12/31/2022]
Abstract
In this review, a brief history and current state-of-the-art is given to stimulate the rational design of new microbubbles through the reverse engineering of current ultrasound contrast agents (UCAs). It is shown that an effective microbubble should be biocompatible, echogenic and stable. Physical mechanisms and engineering calculations have been provided to illustrate these properties and how they can be achieved. The reverse-engineering design paradigm is applied to study current FDA-approved and commercially available UCAs. Given the sophistication of microbubble designs reported in the literature, rapid development and adoption of ultrasound device hardware and techniques, and the growing number of revolutionary biomedical applications moving toward the clinic, the field of Microbubble Engineering is fertile for breakthroughs in next-generation UCA technology. It is up to current and future microbubble engineers and clinicians to push forward with regulatory approval and clinical adoption of advanced UCA technologies in the years to come.
Collapse
Affiliation(s)
- Mark A Borden
- Mechanical Engineering, University of Colorado, Boulder, CO 80309-0427, USA.
| | - Kang-Ho Song
- Mechanical Engineering, University of Colorado, Boulder, CO 80309-0427, USA
| |
Collapse
|
22
|
Dmitriev DS, Ivakhiv MV, Agafonov DV. Evaluation of the Lyophilicity of Activated Carbons for Supercapacitors. RUSS J APPL CHEM+ 2018. [DOI: 10.1134/s1070427218030229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
23
|
Mulvana H, Browning RJ, Luan Y, de Jong N, Tang MX, Eckersley RJ, Stride E. Characterization of Contrast Agent Microbubbles for Ultrasound Imaging and Therapy Research. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:232-251. [PMID: 27810805 DOI: 10.1109/tuffc.2016.2613991] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The high efficiency with which gas microbubbles can scatter ultrasound compared with the surrounding blood pool or tissues has led to their widespread employment as contrast agents in ultrasound imaging. In recent years, their applications have been extended to include super-resolution imaging and the stimulation of localized bio-effects for therapy. The growing exploitation of contrast agents in ultrasound and in particular these recent developments have amplified the need to characterize and fully understand microbubble behavior. The aim in doing so is to more fully exploit their utility for both diagnostic imaging and potential future therapeutic applications. This paper presents the key characteristics of microbubbles that determine their efficacy in diagnostic and therapeutic applications and the corresponding techniques for their measurement. In each case, we have presented information regarding the methods available and their respective strengths and limitations, with the aim of presenting information relevant to the selection of appropriate characterization methods. First, we examine methods for determining the physical properties of microbubble suspensions and then techniques for acoustic characterization of both suspensions and single microbubbles. The next section covers characterization of microbubbles as therapeutic agents, including as drug carriers for which detailed understanding of their surface characteristics and drug loading capacity is required. Finally, we discuss the attempts that have been made to allow comparison across the methods employed by various groups to characterize and describe their microbubble suspensions and promote wider discussion and comparison of microbubble behavior.
Collapse
|