1
|
Wen P, Liu L, Pan L, Li X. Evaluating diagnostic significance: The utilization of elastography and contrast-enhanced ultrasound for differential diagnosis in breast lesions. Clin Hemorheol Microcirc 2024:CH242216. [PMID: 38758994 DOI: 10.3233/ch-242216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/19/2024]
Abstract
OBJECTIVE The primary aim of this study is to assess the diagnostic efficacy of elastography and contrast-enhanced ultrasound (CEUS) in the identification of breast lesions subsequent to the optimization and correction of the BI-RADS category 4 classification obtained through conventional ultrasound. The objective is to augment both the specificity and accuracy of breast lesion diagnosis, thereby establishing a reliable framework for reducing unnecessary biopsies in clinical settings. METHODS A cohort comprising 50 cases of breast lesions classified under BI-RADS category 4 was collected during the period from November 2022 and November 2023. These cases were examined utilizing strain elastography (SE), shear wave elastography (SWE), and CEUS. Novel scoring methodologies for ultrasonic elastography (UE) and CEUS were formulated for this investigation. Subsequently, the developed UE and CEUS scoring systems were used to refine and optimize the conventional BI-RADS classification, either in isolation or in conjunction. Based on the revised classification, the benign group was classified as category 3 and the suspected malignant group was classified as category 4a and above, with pathological results serving as the definitive reference standard. The diagnostic efficacy of the optimized UE and CEUS, both independently and in combination, was meticulously scrutinized and compared using receiver operating characteristic (ROC) curve analysis, with pathological findings as the reference standard. RESULTS Within the study group, malignancy manifested in 11 cases. Prior to the implementation of the optimization criteria, 78% (39 out of 50) of patients underwent biopsies deemed unnecessary. Following the application of optimization criteria, specifically a threshold of≥8.5 points for the UE scoring method and≥6.5 points for the CEUS scoring method, the incidence of unnecessary biopsies diminished significantly. Reduction rates were observed at 53.8% (21 out of 39) with the UE protocol, 56.4% (22 out of 39) with the CEUS protocol, and 89.7% (35 out of 39) with the combined UE and CEUS optimization protocols. CONCLUSION The diagnostic efficacy of conventional ultrasound BI-RADS category 4 classification for breast lesions is enhanced following optimized correction using UE and CEUS, either independently or in conjunction. The application of the combined protocol demonstrates a notable reduction in the incidence of unnecessary biopsies.
Collapse
Affiliation(s)
- Peng Wen
- Department of Ultrasound, Jilin Province People's Hospital, Changchun, Jilin, China
| | - Lei Liu
- Department of Ultrasound, The First Hospital of Jilin University, Changchun, Jilin, China
| | - Lili Pan
- Department of Ultrasound, Jilin Province People's Hospital, Changchun, Jilin, China
| | - Xiukun Li
- Department of Ultrasound, Jilin Province People's Hospital, Changchun, Jilin, China
| |
Collapse
|
2
|
Demirci BÖ, Buğdaycı O, Ertaş G, Şanlı DET, Kaya H, Arıbal E. Linear Regression Modeling Based Scoring System to Reduce Benign Breast Biopsies Using Multi-parametric US with Color Doppler and SWE. Acad Radiol 2023; 30 Suppl 2:S143-S153. [PMID: 36804295 DOI: 10.1016/j.acra.2023.01.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 01/15/2023] [Accepted: 01/17/2023] [Indexed: 02/18/2023]
Abstract
RATIONALE AND OBJECTIVES To develop a simple ultrasound (US) based scoring system to reduce benign breast biopsies. MATERIALS AND METHODS Women with BI-RADS 4 or 5 breast lesions underwent shear-wave elastography (SWE) imaging before biopsy. Standard US and color Doppler US (CDUS) parameters were recorded, and the size ratio (SzR=longest/shortest diameter) was calculated. Measured/calculated SWE parameters were minimum (SWVMin) and maximum (SWVMax) shear velocity, velocity heterogeneity (SWVH=SWVMax-SWVMin), velocity ratio (SWVR=SWVMin/SWVMax), and normalized SWVR (SWVRn=(SWVMax-SWVMin)/SWVMin). Linear regression analysis was performed by converting continuous parameters into categorical corresponding equivalents using decision tree analyses. Linear regression models were fitted using stepwise regression analysis and optimal coefficients for the predictors in the models were determined. A scoring model was devised from the results and validated using a different data set from another center consisting of 187 cases with BI-RADS 3, 4, and 5 lesions. RESULTS A total of 418 lesions (238 benign, 180 malignant) were analyzed. US and CDUS parameters exhibited poor (AUC=0.592-0.696), SWE parameters exhibited poor-good (AUC=0.607-0.816) diagnostic performance in benign/malignant discrimination. Linear regression models of US+CDUS and US+SWE parameters revealed an AUC of 0.819 and 0.882, respectively. The developed scoring system could have avoided biopsy in 37.8% of benign lesions while missing 1.1% of malignant lesions. The scoring system was validated with a 100% NPV rate with a specificity of 74.6%. CONCLUSION The linear regression model using US+SWE parameters performed better than any single parameter alone. The developed scoring method could lead to a significant decrease in benign biopsies.
Collapse
Affiliation(s)
| | - Onur Buğdaycı
- Department of Radiology, Marmara University, Istanbul, Türkiye.
| | - Gökhan Ertaş
- Department of Biomedical Engineering, Yeditepe University, Istanbul, Türkiye
| | - Deniz E T Şanlı
- Department of Radiology, Acibadem Kozyatagi Hospital, Istanbul, Türkiye; Department of Radiology, Gaziantep University, Gaziantep, Türkiye
| | - Handan Kaya
- Department of Pathology, Marmara University, Istanbul, Türkiye
| | - Erkin Arıbal
- Department of Radiology, Marmara University, Istanbul, Türkiye; Department of Radiology, Acıbadem University Medical School, Istanbul, Türkiye
| |
Collapse
|
3
|
Yao S, Liu X, Wang H, Yu H. Evaluation of renal parenchyma stiffness in children with nephropathy by shear wave elastography: A systematic review and meta-analysis. Int J Urol 2023; 30:28-35. [PMID: 36125940 DOI: 10.1111/iju.15054] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 09/07/2022] [Indexed: 01/31/2023]
Abstract
BACKGROUND The role of shear wave elastography (SWE) in assessing renal parenchymal stiffness in children with nephropathy is obscure. This systematic review and meta-analysis investigated this issue. MATERIALS AND METHODS PubMed, Embase, Web of Science, and the Cochrane Library databases were searched for studies evaluating renal parenchyma stiffness in children with nephropathy by SWE from inception to October 2021. The search was not limited by language. Two investigators independently screened the literature and extracted data. Any discrepancies were resolved via discussion with the senior professor. Study quality was assessed by the Newcastle-Ottawa Scale and the standardized mean difference of shear wave velocity (SWV) for the evaluation of renal parenchyma stiffness was determined. RESULTS Eight studies involving a total of 496 children with nephropathy and 353 healthy children were selected. Eight studies used SWV as parameters of renal parenchyma stiffness. The SWV was not significantly different in children with renal lesion than in those without renal lesion, with a standardized mean difference of 0.49 (95% confidence level, -0.40 to 1.39, p = 0.28). There was a high heterogeneity between studies. CONCLUSION Although there was significant difference in SWE of renal parenchyma between controls and patients in each study we included, statistical differences were not seen after results of all research were amalgamated due to different diseases with different pathomechanisms. SWE could be used to evaluate renal parenchymal stiffness in children with kidney disease after more well-designed and high-quality studies with a large sample size will be performed in the future.
Collapse
Affiliation(s)
- Shixiang Yao
- Department of Ultrasonography, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Xiao Liu
- Department of Ultrasonography, Shenzhen Hospital of Guangzhou University of Chinese Medicine, Shenzhen, Guangdong, China
| | - Hongying Wang
- Department of Ultrasonography, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Hongkui Yu
- Department of Ultrasonography, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, China
| |
Collapse
|
4
|
Wiacek A, Oluyemi E, Myers K, Ambinder E, Bell MAL. Coherence Metrics for Reader-Independent Differentiation of Cystic From Solid Breast Masses in Ultrasound Images. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:256-268. [PMID: 36333154 PMCID: PMC9712258 DOI: 10.1016/j.ultrasmedbio.2022.08.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 08/22/2022] [Accepted: 08/28/2022] [Indexed: 06/16/2023]
Abstract
Traditional breast ultrasound imaging is a low-cost, real-time and portable method to assist with breast cancer screening and diagnosis, with particular benefits for patients with dense breast tissue. We previously demonstrated that incorporating coherence-based beamforming additionally improves the distinction of fluid-filled from solid breast masses, based on qualitative image interpretation by board-certified radiologists. However, variable sensitivity (range: 0.71-1.00 when detecting fluid-filled masses) was achieved by the individual radiologist readers. Therefore, we propose two objective coherence metrics, lag-one coherence (LOC) and coherence length (CL), to quantitatively determine the content of breast masses without requiring reader assessment. Data acquired from 31 breast masses were analyzed. Ideal separation (i.e., 1.00 sensitivity and specificity) was achieved between fluid-filled and solid breast masses based on the mean or median LOC value within each mass. When separated based on mean and median CL values, the sensitivity/specificity decreased to 1.00/0.95 and 0.92/0.89, respectively. The greatest sensitivity and specificity were achieved in dense, rather than non-dense, breast tissue. These results support the introduction of an objective, reader-independent method for automated diagnoses of cystic breast masses.
Collapse
Affiliation(s)
- Alycen Wiacek
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland, USA.
| | - Eniola Oluyemi
- Department of Radiology and Radiological Science, Johns Hopkins Medicine, Baltimore, Maryland, USA
| | - Kelly Myers
- Department of Radiology and Radiological Science, Johns Hopkins Medicine, Baltimore, Maryland, USA
| | - Emily Ambinder
- Department of Radiology and Radiological Science, Johns Hopkins Medicine, Baltimore, Maryland, USA
| | - Muyinatu A Lediju Bell
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland, USA; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA; Department of Computer Science, Johns Hopkins University, Baltimore, Maryland, USA
| |
Collapse
|
5
|
Dong Y, Koch J, Alhyari A, Safai Zadeh E, Görg C, Wang WP, Berzigotti A, Dietrich CF. Ultrasound Elastography for Characterization of Focal Liver Lesions. ZEITSCHRIFT FÜR GASTROENTEROLOGIE 2022; 61:399-410. [PMID: 36516951 DOI: 10.1055/a-1957-7370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
AbstractFocal liver lesions (FLL) are typically detected by conventional ultrasound or other
imaging modalities. After the detection of FLL, further characterization is essential, and
this can be done by contrast-enhanced imaging techniques, e.g., contrast-enhanced ultrasound
(CEUS) and magnetic resonance imaging (MRI) or by means of biopsy with histological
evaluation. Elastographic techniques are nowadays integrated into high-end ultrasound systems
and their value for the detection of severe liver fibrosis and cirrhosis has been shown in
studies and meta-analyses. The use of an ultrasound elastographic technique for the
differentiation of malignant and benign liver tumors is less well-established. This review
summarizes the current data on utility and performance of ultrasound elastography for the
characterization of FLL.
Collapse
Affiliation(s)
- Yi Dong
- Department of Ultrasound, Zhongshan Hospital Fudan University, Shanghai, China
- Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Jonas Koch
- Department Allgemeine Innere Medizin, Kliniken (DAIM) Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland
| | - Amjad Alhyari
- Gastroenterology, Endocrinology, Metabolism and Clinical Infectiology, Interdisciplinary Center of Ultrasound Diagnostics, University Hospital Giessen and Marburg, Philipps University Marburg, Marburg, Germany
| | - Ehsan Safai Zadeh
- Gastroenterology, Endocrinology, Metabolism and Clinical Infectiology, Interdisciplinary Center of Ultrasound Diagnostics, University Hospital Giessen and Marburg, Philipps University Marburg, Marburg, Germany
| | - Christian Görg
- Gastroenterology, Endocrinology, Metabolism and Clinical Infectiology, Interdisciplinary Center of Ultrasound Diagnostics, University Hospital Giessen and Marburg, Philipps University Marburg, Marburg, Germany
| | - Wen-Ping Wang
- Department of Ultrasound, Zhongshan Hospital Fudan University, Shanghai, China
| | - Annalisa Berzigotti
- Department of Visceral Surgery and Medicine, Bern University Hospital, University of Bern, Berne, Switzerland
| | - Christoph F. Dietrich
- Department Allgemeine Innere Medizin, Kliniken (DAIM) Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland
| |
Collapse
|
6
|
Quantitative Assessment of Breast-Tumor Stiffness Using Shear-Wave Elastography Histograms. Diagnostics (Basel) 2022; 12:diagnostics12123140. [PMID: 36553148 PMCID: PMC9777730 DOI: 10.3390/diagnostics12123140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/08/2022] [Accepted: 12/11/2022] [Indexed: 12/15/2022] Open
Abstract
Purpose: Shear-wave elastography (SWE) measures tissue elasticity using ultrasound waves. This study proposes a histogram-based SWE analysis to improve breast malignancy detection. Methods: N = 22/32 (patients/tumors) benign and n = 51/64 malignant breast tumors with histological ground truth. Colored SWE heatmaps were adjusted to a 0−180 kPa scale. Normalized, 250-binned RGB histograms were used as image descriptors based on skewness and area under curve (AUC). The histogram method was compared to conventional SWE metrics, such as (1) the qualitative 5-point scale classification and (2) average stiffness (SWEavg)/maximal tumor stiffness (SWEmax) within the tumor B-mode boundaries. Results: The SWEavg and SWEmax did not discriminate malignant lesions in this database, p > 0.05, rank sum test. RGB histograms, however, differed between malignant and benign tumors, p < 0.001, Kolmogorov−Smirnoff test. The AUC analysis of histograms revealed the reduction of soft-tissue components as a significant SWE biomarker (p = 0.03, rank sum). The diagnostic accuracy of the suggested method is still low (Se = 0.30 for Se = 0.90) and a subject for improvement in future studies. Conclusions: Histogram-based SWE quantitation improved the diagnostic accuracy for malignancy compared to conventional average SWE metrics. The sensitivity is a subject for improvement in future studies.
Collapse
|
7
|
Pillai A, Voruganti T, Barr R, Langdon J. Diagnostic Accuracy of Shear-Wave Elastography for Breast Lesion Characterization in Women: A Systematic Review and Meta-Analysis. J Am Coll Radiol 2022; 19:625-634.e0. [PMID: 35358483 DOI: 10.1016/j.jacr.2022.02.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 02/01/2022] [Accepted: 02/03/2022] [Indexed: 12/21/2022]
Abstract
PURPOSE The aim of this study was to assess the diagnostic accuracy of 2-D shear-wave elastography (SWE) for differentiating benign and malignant breast lesions in women with abnormal findings on mammography. METHODS Included in this review are studies of diagnostic accuracy published before June 2021 using 2-D SWE to evaluate female breast lesions. Included studies were required to include at least 50 lesions, report quantitative shear-wave speed (SWS) thresholds, and include a reference standard of either biopsy or 2-year stability. Included studies used the mean, maximum, minimum, or SD of SWS for classification. A systematic search of PubMed, Scopus, Embase, Ovid-MEDLINE, the Cochrane Library, and Web of Science was performed. Bias and applicability of the studies were assessed using Quality Assessment of Diagnostic Accuracy Studies 2. A hierarchical summary receiver operating characteristic model was used to arrive at the summary statistics. RESULTS Eighty-seven prospective and retrospective studies were included, encompassing 17,810 women (mean age 42.3 ± 10.4 years) with 19,043 lesions (7,623 malignant). Summary sensitivities and specificities, respectively, were 0.86 (95% confidence interval [CI], 0.83-0.88) and 0.87 (95% CI, 0.84-0.88) for mean SWS, 0.83 (95% CI, 0.80-0.85) and 0.88 (95% CI, 0.86-0.90) for the maximum, 0.86 (95% CI, 0.74-0.93) and 0.81 (95% CI, 0.69-0.89) for the minimum, and 0.82 (95% CI, 0.77-0.86) and 0.88 (95% CI, 0.85-0.91) for the SD. Alternatively, the areas under the receiver operating characteristic curve were 0.93 (95% CI, 0.91-0.94), 0.92 (95% CI, 0.90-0.94), 0.90 (95% CI, 0.82-0.96), and 0.92 (95% CI, 0.88-0.94), respectively. CONCLUSIONS This review demonstrates the discriminative power of SWE in the diagnosis of breast cancer. Using the resulting likelihood ratios, SWE may prove beneficial in downgrading BI-RADS® 4a or upgrading BI-RADS 3 lesions. However, current society guidelines do not provide definitive recommendations regarding the use of SWE and its counterpart strain elastography (SE). Comparison with our results suggests that SE alone or a combination of SE and SWE may provide better diagnostic performance than SWE alone and serve as an adjunct to current diagnostic techniques.
Collapse
Affiliation(s)
| | | | - Richard Barr
- Northeastern Ohio Medical University, Rootstown, Ohio; President, Radiology Consultants Inc., Youngstown, Ohio
| | | |
Collapse
|
8
|
Physical Forces in Glioblastoma Migration: A Systematic Review. Int J Mol Sci 2022; 23:ijms23074055. [PMID: 35409420 PMCID: PMC9000211 DOI: 10.3390/ijms23074055] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 03/31/2022] [Accepted: 04/04/2022] [Indexed: 02/01/2023] Open
Abstract
The invasive capabilities of glioblastoma (GBM) define the cancer’s aggressiveness, treatment resistance, and overall mortality. The tumor microenvironment influences the molecular behavior of cells, both epigenetically and genetically. Current forces being studied include properties of the extracellular matrix (ECM), such as stiffness and “sensing” capabilities. There is currently limited data on the physical forces in GBM—both relating to how they influence their environment and how their environment influences them. This review outlines the advances that have been made in the field. It is our hope that further investigation of the physical forces involved in GBM will highlight new therapeutic options and increase patient survival. A search of the PubMed database was conducted through to 23 March 2022 with the following search terms: (glioblastoma) AND (physical forces OR pressure OR shear forces OR compression OR tension OR torsion) AND (migration OR invasion). Our review yielded 11 external/applied/mechanical forces and 2 tumor microenvironment (TME) forces that affect the ability of GBM to locally migrate and invade. Both external forces and forces within the tumor microenvironment have been implicated in GBM migration, invasion, and treatment resistance. We endorse further research in this area to target the physical forces affecting the migration and invasion of GBM.
Collapse
|
9
|
2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection. PLoS One 2022; 17:e0265802. [PMID: 35344561 PMCID: PMC8959156 DOI: 10.1371/journal.pone.0265802] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 03/08/2022] [Indexed: 12/12/2022] Open
Abstract
Purpose
To assess the ability of 2D-Shear wave elastography (2D-SWE) to evaluate its reproducibility, to define the optimal orientation and size of the region of interest (ROI), and to differentiate benign from malignant inguinal lymph nodes (LNs).
Method
Thirty-two suspicious inguinal LNs from 21 patients were evaluated with 2D-SWE. SWE measurements were obtained in two orthogonal planes. To investigate reproducibility, sensitivity and specificity, circular ROIs with a diameter of 1 mm, 2 mm, 3 mm and 5 mm were placed on the cortex of the LNs. Additionally, one freehand ROI was drawn covering majority of the LN. Two observers performed five sets of SWE measurements for each ROI size. All LNs underwent core needle biopsy or were surgically removed.
Results
The 3 mm ROI for Mean-E in axial plane showed high interrater agreement [intraclass correlation coefficient (ICC) 0.899] with the cut-off value of 7.31 kPa resulting in 88.9% sensitivity and 60.9% specificity for differentiating malignant from benign LNs. In benign LNs, mean elasticity of the ROI was lower (7.68 ± 3.82 kPa; range, 3.41–15.40 kPa) compared to the malignant LNs (15.81 ± 10.61 kPa; range, 3.86–36.45 kPa).
Conclusions
The most reproducible way to measure stiffness in inguinal LNs is a 3 mm circular ROI centered on the cortex of the LN in axial plane. Elasticity values were higher in the malignant LNs reflecting the stiffer nature of the metastatic LNs. 2D-SWE offers a noninvasive ultrasonographic tool to assess superficial inguinal lymph nodes with high reproducibility.
Collapse
|
10
|
Koorman T, Jansen KA, Khalil A, Haughton PD, Visser D, Rätze MAK, Haakma WE, Sakalauskaitè G, van Diest PJ, de Rooij J, Derksen PWB. Spatial collagen stiffening promotes collective breast cancer cell invasion by reinforcing extracellular matrix alignment. Oncogene 2022; 41:2458-2469. [PMID: 35292774 PMCID: PMC9033577 DOI: 10.1038/s41388-022-02258-1] [Citation(s) in RCA: 47] [Impact Index Per Article: 23.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 02/04/2022] [Accepted: 02/18/2022] [Indexed: 01/29/2023]
Abstract
The tumor micro-environment often contains stiff and irregular-bundled collagen fibers that are used by tumor cells to disseminate. It is still unclear how and to what extent, extracellular matrix (ECM) stiffness versus ECM bundle size and alignment dictate cancer cell invasion. Here, we have uncoupled Collagen-I bundling from stiffness by introducing inter-collagen crosslinks, combined with temperature induced aggregation of collagen bundling. Using organotypic models from mouse invasive ductal and invasive lobular breast cancers, we show that increased collagen bundling in 3D induces a generic increase in breast cancer invasion that is independent of migration mode. However, systemic collagen stiffening using advanced glycation end product (AGE) crosslinking prevents collective invasion, while leaving single cell invasion unaffected. Collective invasion into collagen matrices by ductal breast cancer cells depends on Lysyl oxidase-like 3 (Loxl3), a factor produced by tumor cells that reinforces local collagen stiffness. Finally, we present clinical evidence that collectively invading cancer cells at the invasive front of ductal breast carcinoma upregulate LOXL3. By uncoupling the mechanical, chemical, and structural cues that control invasion of breast cancer in three dimensions, our data reveal that spatial control over stiffness and bundling underlie collective dissemination of ductal-type breast cancers.
Collapse
Affiliation(s)
- Thijs Koorman
- grid.7692.a0000000090126352Departments of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Karin A. Jansen
- grid.7692.a0000000090126352Departments of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Antoine Khalil
- grid.7692.a0000000090126352Molecular Cancer Research/Center for Molecular Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Peter D. Haughton
- grid.7692.a0000000090126352Departments of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Daan Visser
- grid.7692.a0000000090126352Departments of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Max A. K. Rätze
- grid.7692.a0000000090126352Departments of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Wisse E. Haakma
- grid.7692.a0000000090126352Departments of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Gabrielè Sakalauskaitè
- grid.7692.a0000000090126352Departments of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Paul J. van Diest
- grid.7692.a0000000090126352Departments of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Johan de Rooij
- grid.7692.a0000000090126352Molecular Cancer Research/Center for Molecular Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Patrick W. B. Derksen
- grid.7692.a0000000090126352Departments of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
11
|
Youk JH, Kwak JY, Lee E, Son EJ, Kim JA. Grayscale Ultrasound Radiomic Features and Shear-Wave Elastography Radiomic Features in Benign and Malignant Breast Masses. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2020; 41:390-396. [PMID: 31703239 DOI: 10.1055/a-0917-6825] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
PURPOSE To identify and compare diagnostic performance of radiomic features between grayscale ultrasound (US) and shear-wave elastography (SWE) in breast masses. MATERIALS AND METHODS We retrospectively collected 328 pathologically confirmed breast masses in 296 women who underwent grayscale US and SWE before biopsy or surgery. A representative SWE image of the mass displayed with a grayscale image in split-screen mode was selected. An ROI was delineated around the mass boundary on the grayscale image and copied and pasted to the SWE image by a dedicated breast radiologist for lesion segmentation. A total of 730 candidate radiomic features including first-order statistics and textural and wavelet features were extracted from each image. LASSO regression was used for data dimension reduction and feature selection. Univariate and multivariate logistic regression was performed to identify independent radiomic features, differentiating between benign and malignant masses with calculation of the AUC. RESULTS Of 328 breast masses, 205 (62.5 %) were benign and 123 (37.5 %) were malignant. Following radiomic feature selection, 22 features from grayscale and 6 features from SWE remained. On univariate analysis, all 6 SWE radiomic features (P < 0.0001) and 21 of 22 grayscale radiomic features (P < 0.03) were significantly different between benign and malignant masses. After multivariate analysis, three grayscale radiomic features and two SWE radiomic features were independently associated with malignant breast masses. The AUC was 0.929 for grayscale US and 0.992 for SWE (P < 0.001). CONCLUSION US radiomic features may have the potential to improve diagnostic performance for breast masses, but further investigation of independent and larger datasets is needed.
Collapse
Affiliation(s)
- Ji Hyun Youk
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea, Republic of
| | - Jin Young Kwak
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea, Republic of
| | - Eunjung Lee
- Computational Science and Engineering, Yonsei University, Seoul, Korea, Republic of
| | - Eun Ju Son
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea, Republic of
| | - Jeong-Ah Kim
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea, Republic of
| |
Collapse
|
12
|
Huang Y, Li F, Han J, Peng C, Li Q, Cao L, Liu Y, Zhou J. Shear Wave Elastography of Breast Lesions: Quantitative Analysis of Elastic Heterogeneity Improves Diagnostic Performance. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1909-1917. [PMID: 31130413 DOI: 10.1016/j.ultrasmedbio.2019.04.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 04/04/2019] [Accepted: 04/12/2019] [Indexed: 06/09/2023]
Abstract
The aim of this study was to evaluate whether quantitative analysis of elastic heterogeneity (EH) could improve the diagnostic performance of shear wave elastography (SWE) in breast lesions. From August 2016 to August 2017, 280 patients were enrolled in this prospective study. All lesions were evaluated with the ultrasound Breast Imaging Reporting and Data System (BI-RADS) and SWE with Virtual Touch tissue imaging quantification. The shear wave velocity (SWV) of the three areas of highest stiffness and lowest stiffness within the lesions were measured to calculate the maximum SWV (SWVmax), mean SWV (SWVmean) and EH. The EH was determined as the difference between the averaged highest SWV and lowest SWV. The diagnostic performance-including the area under the receiver operating characteristic curve (AUC) and the sensitivity and specificity of BI-RADS, EH, SWVmax and SWVmean-were analyzed. The AUC of EH, SWVmax and SWVmean were 0.963, 0.949 and 0.937, respectively. The sensitivity of EH was 93.75%, which was significantly higher than that of SWVmax (84.37%) and SWVmean (84.37%) (p < 0.001); there was no significant difference in the specificity among EH, SWVmax and SWVmean (p > 0.05). For category 4A lesions, EH predicted all the malignant lesions, while two cancers were misdiagnosed by SWVmax and SWVmean, respectively. Quantitative analysis of EH can improve the sensitivity of SWE for the differential diagnosis of breast lesions without loss of specificity.
Collapse
Affiliation(s)
- Yini Huang
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Fei Li
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Jing Han
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Chuan Peng
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Qing Li
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Longhui Cao
- Department of Anesthesiology, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China.
| | - Yubo Liu
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Jianhua Zhou
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China.
| |
Collapse
|
13
|
Shang J, Ruan LT, Wang YY, Zhang XJ, Dang Y, Liu B, Wang WL, Song Y, Chang SJ. Utilizing size-based thresholds of stiffness gradient to reclassify BI-RADS category 3-4b lesions increases diagnostic performance. Clin Radiol 2019; 74:306-313. [PMID: 30755314 DOI: 10.1016/j.crad.2019.01.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Accepted: 01/08/2019] [Indexed: 01/16/2023]
Abstract
AIM To investigate the role of utilizing size-based thresholds of stiffness gradient in diagnosing solid breast lesions and optimizing original Breast Imaging-Reporting And Data System (BI-RADS) classifications. MATERIALS AND METHODS Two-hundred and twenty-seven consecutive women underwent shear-wave elastography (SWE) before ultrasound-guided biopsy, and 234 solid breast lesions categorized as BI-RADS 3-5 were analysed. Receiver operating characteristic curve analysis was performed based on histopathology. Diagnostic performance among SWE, BI-RADS, and their combination were compared. RESULTS The stiffness gradient correlated with the standard deviation of elasticity (SD, r=0.90), and with Tozaki's pattern classification (r=0.64). The area under the receiver operating characteristic curves (AUC) for stiffness gradient (0.939) outperformed SD (0.897) or colour pattern (0.852). Due to significant association with lesion size (r=0.394, p<0.001), stiffness gradient's size-based thresholds (lesions >15 mm: 82.5 kPa; lesions ≤15 mm: 51.1 kPa) were established to reclassify BI-RADS 3-4b lesions. Upgrading category 3 lesions (over the corresponding cut-off value, 3 to 4a) and downgrading categories 4a-4b lesions (less than or equal to the corresponding cut-off value, 4b to 4a, 4a to 3), yielded significant improvement in specificity (90.28% versus 77.78%, p<0.001) and AUC (0.948 versus 0.926, p=0.035) than BI-RADS alone. No significant loss emerged in the sensitivity (88.89% versus 91.11%, p=0.500). CONCLUSION Stiffness gradient exhibited better discriminatory ability than SD or four-colour pattern classification in determining solid breast lesions and applying its size-specific thresholds to categorize BI-RADS 3-4b lesions could improve diagnostic performance.
Collapse
Affiliation(s)
- J Shang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - L-T Ruan
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China.
| | - Y-Y Wang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - X-J Zhang
- Department of Pathology, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - Y Dang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - B Liu
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China; Department of Ultrasound Diagnosis, Shaanxi Province People's Hospital, Xi'an 710068, China
| | - W-L Wang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China; Department of Ultrasound Diagnosis, Xi'an NO.3 Hospital, Xi'an 710018, China
| | - Y Song
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - S-J Chang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| |
Collapse
|
14
|
Na XMD, Bei XMD, Wei SMD, Ningning TMD, ZhiXia WMD, Binxuan HMD, Hongwei TMD. Dual Modal Ultrasound Elastography of the Sternocleidomastoid Muscle in Healthy Infants: A Prospective Study. ADVANCED ULTRASOUND IN DIAGNOSIS AND THERAPY 2019. [DOI: 10.37015/audt.2019.191219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
|
15
|
Youk JH, Son EJ, Han K, Gweon HM, Kim JA. Performance of shear-wave elastography for breast masses using different region-of-interest (ROI) settings. Acta Radiol 2018; 59:789-797. [PMID: 29058962 DOI: 10.1177/0284185117735562] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Background Various size and shape of region of interest (ROI) can be applied for shear-wave elastography (SWE). Purpose To investigate the diagnostic performance of SWE according to ROI settings for breast masses. Material and Methods To measure elasticity for 142 lesions, ROIs were set as follows: circular ROIs 1 mm (ROI-1), 2 mm (ROI-2), and 3 mm (ROI-3) in diameter placed over the stiffest part of the mass; freehand ROIs drawn by tracing the border of mass (ROI-M) and the area of peritumoral increased stiffness (ROI-MR); and circular ROIs placed within the mass (ROI-C) and to encompass the area of peritumoral increased stiffness (ROI-CR). Mean (Emean), maximum (Emax), and standard deviation (ESD) of elasticity values and their areas under the receiver operating characteristic (ROC) curve (AUCs) for diagnostic performance were compared. Results Means of Emean and ESD significantly differed between ROI-1, ROI-2, and ROI-3 ( P < 0.0001), whereas means of Emax did not ( P = 0.50). For ESD, ROI-1 (0.874) showed a lower AUC than ROI-2 (0.964) and ROI-3 (0.975) ( P < 0.002). The mean ESD was significantly different between ROI-M and ROI-MR and between ROI-C and ROI-CR ( P < 0.0001). The AUCs of ESD in ROI-M and ROI-C were significantly lower than in ROI-MR ( P = 0.041 and 0.015) and ROI-CR ( P = 0.007 and 0.004). Conclusion Shear-wave elasticity values and their diagnostic performance vary based on ROI settings and elasticity indices. Emax is recommended for the ROIs over the stiffest part of mass and an ROI encompassing the peritumoral area of increased stiffness is recommended for elastic heterogeneity of mass.
Collapse
Affiliation(s)
- Ji Hyun Youk
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Eun Ju Son
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Kyunghwa Han
- Yonsei Biomedical Research Institute, Department of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Hye Mi Gweon
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jeong-Ah Kim
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
16
|
Fiorino S, Di Saverio S, Leandri P, Tura A, Birtolo C, Silingardi M, de Biase D, Avisar E. The role of matricellular proteins and tissue stiffness in breast cancer: a systematic review. Future Oncol 2018; 14:1601-1627. [PMID: 29939077 DOI: 10.2217/fon-2017-0510] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Malignancies consist not only of cancerous and nonmalignant cells, but also of additional elements, as extracellular matrix. The aim of this review is to summarize meta-analyses, describing breast tissue stiffness and risk of breast carcinoma (BC) assessing the potential relationship between matricellular proteins (MPs) and survival. A systematic computer-based search of published articles, according to PRISMA statement, was conducted through Ovid interface. Mammographic density and tissue stiffness are associated with the risk of BC development, suggesting that MPs may influence BC prognosis. No definitive conclusions are available and additional researches are required to definitively clarify the role of each MP, mammographic density and stiffness in BC development and the mechanisms involved in the onset of this malignancy.
Collapse
Affiliation(s)
- Sirio Fiorino
- Internal Medicine 'C' Unit, Maggiore Hospital, Local Health Unit of Bologna, Bologna, Italy
| | - Salomone Di Saverio
- Cambridge Colorectal Unit, Box 201, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge Biomedical Campus, Hills Road, Cambridge CB2 0QQ, UK
| | - Paolo Leandri
- Internal Medicine 'C' Unit, Maggiore Hospital, Local Health Unit of Bologna, Bologna, Italy
| | - Andrea Tura
- Metabolic Unit, CNR Institute of Neuroscience, Padova, Italy
| | - Chiara Birtolo
- Geriatric Unit, Azienda USL-Maggiore Hospital, Largo Nigrisoli 3, Bologna, Italy
| | - Mauro Silingardi
- Internal Medicine 'A' Unit, Maggiore Hospital, Local Health Unit of Bologna, Bologna, Italy
| | - Dario de Biase
- Department of Pharmacy & Biotechnology, Molecular Pathology Unit, University of Bologna, Bologna, Italy
| | - Eli Avisar
- Division of Surgical Oncology, Department of Surgery, Miller School of Medicine, University of Miami, Miami, FL 33136, USA
| |
Collapse
|
17
|
Rominger MB, Kälin P, Mastalerz M, Martini K, Klingmüller V, Sanabria S, Frauenfelder T. Influencing Factors of 2D Shear Wave Elastography of the Muscle - An Ex Vivo Animal Study. Ultrasound Int Open 2018; 4:E54-E60. [PMID: 30250941 PMCID: PMC6148312 DOI: 10.1055/a-0619-6058] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Revised: 03/27/2018] [Accepted: 03/29/2018] [Indexed: 02/07/2023] Open
Abstract
OBJECTIVE To evaluate measurement confounders on 2D shear wave elastography (2D-SWE) elastography of muscle. MATERIALS AND METHODS Ex vivo , porcine muscle was examined with a GE LOGIQ E9 ultrasound machine with a 9 L linear (9 MHz) and C1-6 convex probe (operating at 2.5 or 6 MHz). The influence of different confounders on mean shear wave velocity (SWVmean) was analyzed: probes, pressure applied by probe, muscle orientation, together with the impact of different machine settings such as frequency, placement depth and size of region of interest (ROI). The mean of twelve repeated SWVmean measurements (m/s) and coefficient of variation (CV; standard deviation/mean in %) were assessed for each test configuration. RESULTS Reproducibility (CV) and maximum possible tissue depth of the linear probe were inferior to the convex probe. With the linear probe, there was a linear decrease of SWVmean with placement depth from 4.56 m/s to 1.81 m/s. A significant increase of SWVmean (p<0.001) was observed for larger ROI widths (range 3.96 m/s to 6.8 m/s). A change in the machine operation mode ('penetration' instead of 'general') led to a significant increase of SWVmean (p=0.04). SWVmean in the longitudinal direction of muscle was significantly higher than in cross section (p<0.001) (e. g. 4.56 m/s versus 3.42 m/s). An increase of linear probe pressure significantly increased muscle SWVmean from 5.29 m/s to 7.21 m/s (p<0.001). CONCLUSIONS 2D-SWE of muscle is influenced by a wealth of parameters. Therefore, standardization of measurement is advisable before application in clinical research studies and routine patient assessment.
Collapse
Affiliation(s)
- Marga B Rominger
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Pascal Kälin
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Monika Mastalerz
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Katharina Martini
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Volker Klingmüller
- Eidgenossische Technische Hochschule Zurich, Computer Vision Laboratory, Zurich, Switzerland
| | - Sergio Sanabria
- Eidgenossische Technische Hochschule Zurich, Computer Vision Laboratory, Zurich, Switzerland
| | - Thomas Frauenfelder
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
18
|
Robbins CM, Raghavan G, Antaki JF, Kainerstorfer JM. Feasibility of spatial frequency-domain imaging for monitoring palpable breast lesions. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-9. [PMID: 28831792 PMCID: PMC5997013 DOI: 10.1117/1.jbo.22.12.121605] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Accepted: 07/27/2017] [Indexed: 05/04/2023]
Abstract
In breast cancer diagnosis and therapy monitoring, there is a need for frequent, noninvasive disease progression evaluation. Breast tumors differ from healthy tissue in mechanical stiffness as well as optical properties, which allows optical methods to detect and monitor breast lesions noninvasively. Spatial frequency-domain imaging (SFDI) is a reflectance-based diffuse optical method that can yield two-dimensional images of absolute optical properties of tissue with an inexpensive and portable system, although depth penetration is limited. Since the absorption coefficient of breast tissue is relatively low and the tissue is quite flexible, there is an opportunity for compression of tissue to bring stiff, palpable breast lesions within the detection range of SFDI. Sixteen breast tissue-mimicking phantoms were fabricated containing stiffer, more highly absorbing tumor-mimicking inclusions of varying absorption contrast and depth. These phantoms were imaged with an SFDI system at five levels of compression. An increase in absorption contrast was observed with compression, and reliable detection of each inclusion was achieved when compression was sufficient to bring the inclusion center within ∼12 mm of the phantom surface. At highest compression level, contrasts achieved with this system were comparable to those measured with single source-detector near-infrared spectroscopy.
Collapse
Affiliation(s)
- Constance M. Robbins
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
| | - Guruprasad Raghavan
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
| | - James F. Antaki
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
| | - Jana M. Kainerstorfer
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
- Address all correspondence to: Jana M. Kainerstorfer, E-mail:
| |
Collapse
|