1
|
Han H, Yang J, Jin WK, Li X, Zhang F, Zhuge YZ, Wu M, Yang B. Diagnostic value of conventional ultrasound and shear wave elastography in detecting transjugular intrahepatic portosystemic shunt dysfunction. Acta Radiol 2021; 62:1575-1582. [PMID: 33251812 DOI: 10.1177/0284185120975183] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction can cause recurrent portal hypertension (PH)-related complications such as ascites and gastroesophageal variceal bleeding. Portography is invasive and costly limits its use as a screening modality. PURPOSE To assess the clinical value of conventional ultrasound in combination with point shear wave elastography (pSWE) to predict TIPS dysfunction. MATERIAL AND METHODS A total of 184 patients with cirrhosis scheduled for TIPS implantation were enrolled in this study and evaluated retrospectively. The splenoportal venous blood flow parameter, liver stiffness (LS), and spleen stiffness (SPS) were measured. Outcome measures included differences in portal vein velocity (PVV), splenic vein velocity (SPVV), LS, and SPS. The accuracy of change in PVV (ΔPVV), SPVV (ΔSPVV), and SPS (ΔSPS) to diagnose TIPS dysfunction was investigated. RESULTS TIPS dysfunction occurred in 28 of 184 patients (15.2%). Eighteen (64.3%) patients had shunt stenoses and 10 (35.7%) had shunt occlusion. Portal vein diameter (PVD), PVV, splenic vein diameter (SPVD), SPVV, LS, and SPS were not significantly different between the TIPS normal and TIPS dysfunction groups. Compared with the TIPS normal group, PVV and SPVV of the TIPS dysfunction group decreased significantly, whereas SPS increased significantly (P < 0.001). The values of areas under the receiver operating characteristic curves of ΔPVV, ΔSPVV, and ΔSPS for the diagnosis of TIPS dysfunction were 0.97, 0.96, and 0.87, respectively. CONCLUSION pSWE showed a diagnostic efficacy comparable to conventional ultrasound for diagnosing TIPS dysfunction and can be used routinely after TIPS procedures.
Collapse
Affiliation(s)
- Hao Han
- Department of Ultrasound, Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University, Nanjing, PR China
| | - Jian Yang
- Department of Ultrasound, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, PR China
| | - Wei-kui Jin
- Department of Ultrasound, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, PR China
| | - Xia Li
- Department of Ultrasound, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, PR China
| | - Feng Zhang
- Department of Gastroenterology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, PR China
| | - Yu-zheng Zhuge
- Department of Gastroenterology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, PR China
| | - Min Wu
- Department of Ultrasound, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, PR China
| | - Bin Yang
- Department of Ultrasound, Jinling Hospital, Nanjing Medical University, Nanjing, PR China
| |
Collapse
|
2
|
Dajti E, Alemanni LV, Marasco G, Montagnani M, Azzaroli F. Approaches to the Diagnosis of Portal Hypertension: Non-Invasive or Invasive Tests? Hepat Med 2021; 13:25-36. [PMID: 33776492 PMCID: PMC7987277 DOI: 10.2147/hmer.s278077] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 02/19/2021] [Indexed: 12/15/2022] Open
Abstract
Portal hypertension is the main driver of complications in patients with advanced chronic liver disease (ACLD) and is defined by values of hepatic venous pressure gradient measurement (HVPG) >5 mmHg. Values of HVPG ≥10 mmHg determine the presence of clinically significant portal hypertension (CSPH), the main predictor of the risk of variceal bleeding, hepatic decompensation, and mortality. However, its measurement is invasive and requires high expertise, so its routine use outside third level centers or clinical trials is limited. In the last decades, several non-invasive tests (NITs) have been developed and validated for the diagnosis of portal hypertension. Among these, liver (LSM) and spleen stiffness measurement (SSM) are the most promising tools available, as they have been proven accurate to predict CSPH, high-risk esophageal varices, decompensation, and mortality in patients with ACLD. In the last Baveno VI Consensus proceedings, LSM evaluation was recommended for the first time for diagnosis of CSPH (LSM >20-25 kPa) and the screening of patients with a low probability of having high-risk varices (LSM <20 kPa and platelet count >150.000/mm3). In this review, we aimed to summarize the growing evidence supporting the use of non-invasive tests for the evaluation of portal hypertension in patients with chronic liver disease.
Collapse
Affiliation(s)
- Elton Dajti
- IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.,Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Luigina Vanessa Alemanni
- IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.,Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Giovanni Marasco
- IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.,Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Marco Montagnani
- IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.,Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Francesco Azzaroli
- IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.,Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| |
Collapse
|
3
|
Spleen Stiffness Predicts Survival after Transjugular Intrahepatic Portosystemic Shunt in Cirrhotic Patients. BIOMED RESEARCH INTERNATIONAL 2020; 2020:3860390. [PMID: 33282945 PMCID: PMC7685811 DOI: 10.1155/2020/3860390] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 10/19/2020] [Accepted: 10/29/2020] [Indexed: 12/21/2022]
Abstract
Objectives Transjugular intrahepatic portosystemic shunt (TIPS) is an effective intervention for portal hypertensive complications. Little is known about the ability of spleen stiffness (SS) for predicting the survival of cirrhotic patients undergoing TIPS. This study is to evaluate the influence of SS detected by point shear wave elastography (pSWE) in predicting survival after TIPS. Methods This retrospective cohort study screened consecutive patients who underwent TIPS and reliable pSWE measurement between October 2014 and September 2017 from our prospectively maintained database. SS values were measured before TIPS. The primary endpoint was the overall survival after TIPS. The Cox regression analysis model was used for univariate and multivariate analyses. A receiver operating characteristic (ROC) curve analysis was performed to calculate the sensitivity, specificity, and positive and negative predictive values. Results A total of 89 patients were involved in the final analysis. 24 patients (27.0%) died during a median follow-up time of 31 m. Multivariable Cox regression analysis confirmed that higher SS value (P < 0.001), LS value (P = 0.008), diameter of shunt (P = 0.001), and older age (P < 0.001) were independent prognostic factors of survival after TIPS. The risk of death rose 57.440-fold for each SS unit (m/s) increase. SS was also correlated with liver failure after TIPS. ROC analysis showed that the best SS cutoff value was 3.60 m/s for predicting survival, with a sensitivity of 54.2% and specificity of 90.8%. Conclusions The SS value determined by pSWE in cirrhotic patients was an independent predictive factor for survival after TIPS.
Collapse
|
4
|
Giunta M, La Mura V, Conti CB, Casazza G, Tosetti G, Gridavilla D, Segato S, Nicolini A, Primignani M, Lampertico P, Fraquelli M. The Role of Spleen and Liver Elastography and Color-Doppler Ultrasound in the Assessment of Transjugular Intrahepatic Portosystemic Shunt Function. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1641-1650. [PMID: 32402671 DOI: 10.1016/j.ultrasmedbio.2020.04.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 03/11/2020] [Accepted: 04/09/2020] [Indexed: 06/11/2023]
Abstract
The reference standard for assessing transjugular intrahepatic portosystemic shunt (TIPS) function is venography with portosystemic pressure gradient (PPG) measurement. This procedure is invasive and expensive; thus, we assessed the feasibility, reproducibility and diagnostic accuracy of color-Doppler ultrasound (CDUS) and spleen and liver stiffness (LS) measurements for identifying TIPS dysfunction. Twenty-four patients (15 undergoing TIPS placement and nine undergoing TIPS revision) consecutively underwent CDUS examination and LS and spleen stiffness (SS) determination by transient elastography (TE) and point shear-wave elastography (pSWE). All parameters were taken before TIPS placement/revision (1-15 d before) and 24 h after, just before revision by venography. pSWE inter-observer agreement was assessed by intra-class correlation coefficient (ICC). CDUS and elastographic data were correlated (Pearson coefficient) with pressure gradients (hepatic venous pressure gradient [HVPG], PPG). Main determinants of TIPS dysfunction were investigated by linear regression. Forty-nine paired examinations were performed in total: 49 (100%) SS reliable measurements by pSWE and 38 (88%) by TE. The ICC for pSWE values was 0.90 (95% confidence interval [CI] 0.81‒0.94). SS values significantly correlated with HVPG and PPG (R = 0.51, p = 0.01). The area under the Receiver-Operating Characteristic (AUROC) curve of SS for diagnosing TIPS dysfunction was 0.86 (95% CI 0.70‒0.96) using a 25 kPa cutoff. At multivariate analysis, the flow direction of the intrahepatic portal vein branches and SS values were independently associated to TIPS dysfunction. The intrahepatic portal vein branches flow direction and SS value are two simple, highly sensitive parameters accurately excluding TIPS dysfunction. SS measurement by pSWE is feasible, reproducible and both positively and significantly correlates with HVPG and PPG values.
Collapse
Affiliation(s)
- Mariangela Giunta
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Gastroenterologia ed Endoscopia, Milan, Italy
| | - Vincenzo La Mura
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Medicina Generale, Emostasi e Trombosi, Milan, Italy; Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milan, Italy; Centro di Ricerca Coordinata "A.M. e A. Migliavacca" per lo Studio e la Cura delle Malattie del Fegato, Milan, Italy; Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Gastroenterologia ed Epatologia, Milan, Italy
| | - Clara Benedetta Conti
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Gastroenterologia ed Endoscopia, Milan, Italy
| | - Giovanni Casazza
- Dipartimento di Scienze Biomediche e Cliniche "L. Sacco", Universita' degli Studi di Milano, Milan, Italy
| | - Giulia Tosetti
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Medicina Generale, Emostasi e Trombosi, Milan, Italy; Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milan, Italy; Centro di Ricerca Coordinata "A.M. e A. Migliavacca" per lo Studio e la Cura delle Malattie del Fegato, Milan, Italy
| | - Daniele Gridavilla
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Gastroenterologia ed Endoscopia, Milan, Italy
| | - Simone Segato
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Gastroenterologia ed Endoscopia, Milan, Italy
| | - Antonio Nicolini
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Radiologia, Milan, Italy
| | - Massimo Primignani
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Medicina Generale, Emostasi e Trombosi, Milan, Italy; Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milan, Italy; Centro di Ricerca Coordinata "A.M. e A. Migliavacca" per lo Studio e la Cura delle Malattie del Fegato, Milan, Italy
| | - Pietro Lampertico
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Medicina Generale, Emostasi e Trombosi, Milan, Italy; Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milan, Italy; Centro di Ricerca Coordinata "A.M. e A. Migliavacca" per lo Studio e la Cura delle Malattie del Fegato, Milan, Italy
| | - Mirella Fraquelli
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, UOC Gastroenterologia ed Endoscopia, Milan, Italy.
| |
Collapse
|
5
|
Bob F, Grosu I, Sporea I, Timar R, Lighezan D, Popescu A, Sirli R, Buzas R, Petrica L, Munteanu M, Schiller A. Is Kidney Stiffness Measured Using Elastography Influenced Mainly by Vascular Factors in Patients with Diabetic Kidney Disease? ULTRASONIC IMAGING 2018; 40:300-309. [PMID: 29848202 DOI: 10.1177/0161734618779789] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Studies published so far using ultrasound-based elastography in the kidneys, lack to prove a clear relationship between kidney shear wave speed (KSWS) and renal disease progression. Taking into account that the kidney is a highly vascularized organ, the present study aims to find a relationship between KSWS and vascular factors (blood pressure [BP], arterial stiffness). Our study included 38 diabetic kidney disease patients (mean age 56.52 ± 16.12 years, 19 female, 19 male). KSWS, an indicator of renal stiffness, was measured using point Shear Wave Elastography (pSWE; Siemens Acuson S2000). In every patient, we recorded BP, and we measured aortic augmentation index (AAI) and brachial pulse wave velocity (PWV), using oscillometry. We found statistically significant indirect correlations of KSWS with indicators of arterial stiffness, such as PWV ( r = -.41, p = .036), and AAI ( r = -.37, p = .031). We found also an indirect correlation of KSWS with diastolic BP ( r = -.65, p = .02) and systolic BP ( r = -.54, p = .008). We found no correlation of KSWS with estimated glomerular filtration rate (eGFR), urinary albumin/creatinine ratio, stage of diabetic retinopathy, or glycated hemoglobin. Our study shows that high BP and the progression of arteriosclerosis (high PWV and AAI), leads to a decrease of renal stiffness. Thus, it seems that KSWS is influenced by renal blood flow, rather than other factors, such as albuminuria or chronic kidney disease stage.
Collapse
Affiliation(s)
- Flaviu Bob
- 1 Nephrology Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| | - Iulia Grosu
- 1 Nephrology Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| | - Ioan Sporea
- 2 Gastroenterology and Hepatology Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| | - Romulus Timar
- 3 Diabetes and Metabolic Diseases Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| | - Daniel Lighezan
- 4 Internal Medicine 1 Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| | - Alina Popescu
- 2 Gastroenterology and Hepatology Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| | - Roxana Sirli
- 2 Gastroenterology and Hepatology Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| | - Roxana Buzas
- 4 Internal Medicine 1 Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| | - Ligia Petrica
- 1 Nephrology Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| | - Mircea Munteanu
- 3 Diabetes and Metabolic Diseases Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| | - Adalbert Schiller
- 1 Nephrology Department, University of Medicine and Pharmacy "V. Babes" Timisoara, Romania
| |
Collapse
|
6
|
Jansen C, Möller P, Meyer C, Kolbe CC, Bogs C, Pohlmann A, Schierwagen R, Praktiknjo M, Abdullah Z, Lehmann J, Thomas D, Strassburg CP, Latz E, Mueller S, Rössle M, Trebicka J. Increase in liver stiffness after transjugular intrahepatic portosystemic shunt is associated with inflammation and predicts mortality. Hepatology 2018; 67:1472-1484. [PMID: 29059466 DOI: 10.1002/hep.29612] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 09/05/2017] [Accepted: 10/18/2017] [Indexed: 12/15/2022]
Abstract
UNLABELLED Transjugular intrahepatic portosystemic shunt (TIPS) efficiently treats complications of portal hypertension. Liver and spleen stiffness might predict clinically significant portal hypertension. This prospective study investigated liver stiffness in patients receiving TIPS regardless of indication. Of 83 included patients, 16 underwent transient elastography immediately before and 30 minutes after TIPS (acute group), while 67 received shear wave elastography of liver and spleen 1 day before and 7 days after TIPS (chronic group) and were followed further. In blood samples obtained before TIPS from cubital, portal, and hepatic veins, levels of several interleukins (IL1b, IL6, IL8, IL10, IL18) and interferon-gamma were analyzed. In 27 patients (5 acute, 22 chronic), it resulted in an increase in liver stiffness of >10%. In 56 patients, liver stiffness decreased or remained unchanged (<10%). Importantly, spleen stiffness measured by shear wave elastography decreased in all patients (chronic group). None of the clinical or laboratory parameters differed between patients with increase in liver stiffness and those without. Of note, patients with increased liver stiffness showed higher overall and/or hepatic venous levels of proinflammatory cytokines at TIPS and higher incidence of organ failure and worse survival after TIPS. C-reactive protein values and increase of >10% in liver stiffness after TIPS were the only independent predictors of mortality in these patients. CONCLUSION This study demonstrates that the presence of systemic inflammation predisposes patients to develop increased liver stiffness after TIPS, a predictor of organ failure and death. (NCT03072615) (Hepatology 2018;67:1472-1484).
Collapse
Affiliation(s)
- Christian Jansen
- Department of Internal Medicine I, University of Bonn, Bonn, Germany
| | - Philipp Möller
- Department of Internal Medicine I, University of Bonn, Bonn, Germany
| | - Carsten Meyer
- Department of Radiology, University of Bonn, Bonn, Germany
| | | | - Christopher Bogs
- Department of Internal Medicine I, University of Bonn, Bonn, Germany
| | | | | | | | - Zeinab Abdullah
- Institute of Experimental Immunology, University of Bonn, Bonn, Germany
| | - Jennifer Lehmann
- Department of Internal Medicine I, University of Bonn, Bonn, Germany
| | - Daniel Thomas
- Department of Radiology, University of Bonn, Bonn, Germany
| | | | - Eicke Latz
- Institute of Innate Immunity, University of Bonn, Bonn, Germany.,University of Massachusetts Medical School, Worcester, MA
| | - Sebastian Mueller
- Center for Alcohol Research, University of Heidelberg and Salem Medical Center, Heidelberg, Germany
| | - Martin Rössle
- Department of Gastroenterology, University Hospital Freiburg, Freiburg, Germany
| | - Jonel Trebicka
- Department of Internal Medicine I, University of Bonn, Bonn, Germany.,European Foundation for the Study of Chronic Liver Failure, Barcelona, Spain.,Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark.,Institute for Bioengineering of Catalonia, Barcelona, Spain
| |
Collapse
|