1
|
Blank V, Heni M, Karlas T. Quantification of Portal Vein Vascularization Using an Automated Post-Processing Video Analysis Tool. Ultrasound Int Open 2023; 9:E2-E10. [PMID: 36950090 PMCID: PMC10027440 DOI: 10.1055/a-1999-7818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Accepted: 12/03/2022] [Indexed: 03/22/2023] Open
Abstract
Purpose Blood flow dynamics represent a diagnostic criterion for many diseases. However, no established reference standard is available. In clinical practice, ultrasound pulsed-wave Doppler (PW-Doppler) is frequently used to assess visceral blood flow, despite its well-known limitations. A quantitative analysis of conventional color Doppler patterns can be performed using an innovative ultrasound-based algorithm (pixel flow analysis, PFA). This tool already shows promising results in obstetrics, but the technique has not yet been evaluated for portal venous blood flow assessment. Methods This prospective exploratory research study evaluated the applicability of PFA in the portal venous system. Measurements of portal venous flow using PFA and PW-Doppler were compared in healthy volunteers (n=20) and in patients with hepatic steatosis (n=10) and liver cirrhosis (n=10). Results In healthy volunteers (60% female, mean age 23 years, BMI 21.5 kg/m 2 [20.4-23.8]), PFA and PW-Doppler showed a strong positive correlation in fasting conditions (r=0.69; 95% CI 0.36-0.87), recording a median blood flow of 834 ml/min (624-1066) and 718 ml/min (620-811), respectively. PFA was also applicable in patients with chronic liver diseases (55% female, age 65 years (55-72); BMI 27.8 kg/m 2 (25.4-30.8)), but the correlation between PFA and PW-Doppler was poor (r=- 0.09) in the subgroup with steatosis. A better correlation (r=0.61) was observed in patients with liver cirrhosis. Conclusion PFA and PW-Doppler assessment of portal venous vascularization showed high agreement in healthy volunteers and patients with liver cirrhosis. Therefore, PFA represents a possible alternative to conventional PW-Doppler sonography for visceral blood flow diagnostics and merits further evaluation.
Collapse
Affiliation(s)
- Valentin Blank
- Division of Gastroenterology, Department of Medicine II, University Hospital Leipzig, Leipzig, Germany
- Department of Gastroenterology and Division of Interdisciplinary Ultrasound, University Hospital Halle, Halle (Saale), Germany
| | - Maria Heni
- Division of Gastroenterology, Department of Medicine II, University Hospital Leipzig, Leipzig, Germany
| | - Thomas Karlas
- Division of Gastroenterology, Department of Medicine II, University Hospital Leipzig, Leipzig, Germany
| |
Collapse
|
2
|
Jensen JA, Schou M, Jorgensen LT, Tomov BG, Stuart MB, Traberg MS, Taghavi I, Oygaard SH, Ommen ML, Steenberg K, Thomsen EV, Panduro NS, Nielsen MB, Sorensen CM. Anatomic and Functional Imaging Using Row-Column Arrays. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2722-2738. [PMID: 35839193 DOI: 10.1109/tuffc.2022.3191391] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming. Resolution can approach the diffraction limit with an isotropic resolution of half a wavelength with low sidelobe levels, and the field of view can be expanded by using convex or lensed RC probes. GPU beamforming allows for three orthogonal planes to be beamformed at 30 Hz, providing near real-time imaging ideal for positioning the probe and improving the operator's workflow. Functional imaging is also attainable using transverse oscillation and dedicated SA sequence for tensor velocity imaging for revealing the full 3-D velocity vector as a function of spatial position and time for both blood velocity and tissue motion estimation. Using RC arrays with commercial contrast agents can reveal super-resolution imaging (SRI) with isotropic resolution below [Formula: see text]. RC arrays can, thus, yield full 3-D imaging at high resolution, contrast, and volumetric rates for both anatomic and functional imaging with the same number of receive channels as current commercial 1-D arrays.
Collapse
|
3
|
Nielsen MB, Søgaard SB, Bech Andersen S, Skjoldbye B, Hansen KL, Rafaelsen S, Nørgaard N, Carlsen JF. Highlights of the development in ultrasound during the last 70 years: A historical review. Acta Radiol 2021; 62:1499-1514. [PMID: 34791887 DOI: 10.1177/02841851211050859] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This review looks at highlights of the development in ultrasound, ranging from interventional ultrasound and Doppler to the newest techniques like contrast-enhanced ultrasound and elastography, and gives reference to some of the valuable articles in Acta Radiologica. Ultrasound equipment is now available in any size and for any purpose, ranging from handheld devices to high-end devices, and the scientific societies include ultrasound professionals of all disciplines publishing guidelines and recommendations. Interventional ultrasound is expanding the field of use of ultrasound-guided interventions into nearly all specialties of medicine, from ultrasound guidance in minimally invasive robotic procedures to simple ultrasound-guided punctures performed by general practitioners. Each medical specialty is urged to define minimum requirements for equipment, education, training, and maintenance of skills, also for medical students. The clinical application of contrast-enhanced ultrasound and elastography is a topic often seen in current research settings.
Collapse
Affiliation(s)
- Michael Bachmann Nielsen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Stinne Byrholdt Søgaard
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Sofie Bech Andersen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Bjørn Skjoldbye
- Department of Radiology, Aleris-Hamlet Hospitals, Copenhagen Denmark
| | - Kristoffer Lindskov Hansen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Søren Rafaelsen
- Department of Radiology, University Hospital of Southern Denmark, Vejle, Denmark
- Faculty of Health Sciences, Institute of Regional Health Research, University of Southern Denmark, Odense, Denmark
| | - Nis Nørgaard
- Department of Urology, Herlev Gentofte Hospital, Copenhagen, Denmark
| | - Jonathan F. Carlsen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
4
|
Brandt AH, Olesen JB, Moshavegh R, Jensen JA, Nielsen MB, Hansen KL. Common Carotid Artery Volume Flow: A Comparison Study between Ultrasound Vector Flow Imaging and Phase Contrast Magnetic Resonance Imaging. Neurol Int 2021; 13:269-278. [PMID: 34201493 PMCID: PMC8293467 DOI: 10.3390/neurolint13030028] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 06/19/2021] [Accepted: 06/20/2021] [Indexed: 11/16/2022] Open
Abstract
Volume flow estimation in the common carotid artery (CCA) can assess the absolute hemodynamic effect of a carotid stenosis. The aim of this study was to compare a commercial vector flow imaging (VFI) setup against the reference method magnetic resonance phase contrast angiography (MRA) for volume flow estimation in the CCA. Ten healthy volunteers were scanned with VFI and MRA over the CCA. VFI had an improved precision of 19.2% compared to MRA of 31.9% (p = 0.061). VFI estimated significantly lower volume flow than MRA (mean difference: 63.2 mL/min, p = 0.017), whilst the correlation between VFI and MRA was strong (R2 = 0.81, p < 0.0001). A Bland–Altman plot indicated a systematic bias. After bias correction, the percentage error was reduced from 41.0% to 25.2%. This study indicated that a VFI setup for volume flow estimation is precise and strongly correlated to MRA volume flow estimation, and after correcting for the systematic bias, VFI and MRA become interchangeable.
Collapse
Affiliation(s)
- Andreas Hjelm Brandt
- Department of Diagnostic Radiology, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark; (M.B.N.); (K.L.H.)
- Correspondence:
| | | | | | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark;
| | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark; (M.B.N.); (K.L.H.)
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Kristoffer Lindskov Hansen
- Department of Diagnostic Radiology, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark; (M.B.N.); (K.L.H.)
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark
| |
Collapse
|
5
|
Brandt AH, Nguyen TQ, Gutte H, Frederik Carlsen J, Moshavegh R, Jensen JA, Bachmann Nielsen M, Hansen KL. Carotid Stenosis Assessment with Vector Concentration before and after Stenting. Diagnostics (Basel) 2020; 10:E420. [PMID: 32575759 PMCID: PMC7345475 DOI: 10.3390/diagnostics10060420] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 06/08/2020] [Accepted: 06/18/2020] [Indexed: 11/16/2022] Open
Abstract
Digital subtraction angiography (DSA) is considered the reference method for the assessment of carotid artery stenosis; however, the procedure is invasive and accompanied by ionizing radiation. Velocity estimation with duplex ultrasound (DUS) is widely used for carotid artery stenosis assessment since no radiation or intravenous contrast is required; however, the method is angle-dependent. Vector concentration (VC) is a parameter for flow complexity assessment derived from the angle independent ultrasound method vector flow imaging (VFI), and VC has shown to correlate strongly with stenosis degree. The aim of this study was to compare VC estimates and DUS estimated peak-systolic (PSV) and end-diastolic velocities (EDV) for carotid artery stenosis patients, with the stenosis degree obtained with DSA. Eleven patients with symptomatic carotid artery stenosis were examined with DUS, VFI, and DSA before and after stent treatment. Compared to DSA, VC showed a strong correlation (r = -0.79, p < 0.001), while PSV (r = 0.68, p = 0.002) and EDV (r = 0.51, p = 0.048) obtained with DUS showed a moderate correlation. VFI using VC calculations may be a useful ultrasound method for carotid artery stenosis and stent patency assessment.
Collapse
Affiliation(s)
- Andreas Hjelm Brandt
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (T.-Q.N.); (H.G.); (J.F.C.); (M.B.N.); (K.L.H.)
| | - Tin-Quoc Nguyen
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (T.-Q.N.); (H.G.); (J.F.C.); (M.B.N.); (K.L.H.)
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Henrik Gutte
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (T.-Q.N.); (H.G.); (J.F.C.); (M.B.N.); (K.L.H.)
| | - Jonathan Frederik Carlsen
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (T.-Q.N.); (H.G.); (J.F.C.); (M.B.N.); (K.L.H.)
| | | | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark;
| | - Michael Bachmann Nielsen
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (T.-Q.N.); (H.G.); (J.F.C.); (M.B.N.); (K.L.H.)
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Kristoffer Lindskov Hansen
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark; (T.-Q.N.); (H.G.); (J.F.C.); (M.B.N.); (K.L.H.)
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark
| |
Collapse
|
6
|
Hansen KL, Møller-Sørensen H, Kjaergaard J, Jensen JA, Nielsen MB. Vector Flow Imaging of the Ascending Aorta in Patients with Tricuspid and Bicuspid Aortic Valve Stenosis Treated with Biological and Mechanical Implants. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:64-72. [PMID: 31677849 DOI: 10.1016/j.ultrasmedbio.2019.09.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 08/26/2019] [Accepted: 09/30/2019] [Indexed: 06/10/2023]
Abstract
Aortic valve stenosis (AS) is treated with biological prostheses (BPs) and mechanical prostheses (MPs). Vector flow imaging (VFI), an angle-independent ultrasound method, can quantify flow complexity (vector concentration (VC)) and secondary rotation (SR). Ten patients (mean age: 70.7 y) with tricuspid AS scheduled for BPs, 10 patients (mean age: 56.2 y) with bicuspid AS scheduled for MPs and 10 patients (mean age: 63.9 y) with normal aortic valves were scanned intra-operatively on the ascending aorta with VFI and conventional spectral Doppler. Bicuspid AS (peak systolic velocity (PSV): 380.9 cm/s, SR: 16.7 Hz, VC: 0.21) had more complex flow (p < 0.02) than tricuspid AS (PSV: 346.1 cm/s, SR: 17.1 Hz, VC: 0.33). Both groups had more complex and faster flow (p < 0.0001) than normal aortic valve patients (PSV: 124.0 cm/s, SR: 4.3 Hz, VC: 0.79). VC (r = 0.87) and SR (r = 0.89) correlated to PSV. After surgery, flow parameters changed (p < 0.0001) for patients with MPs (PSV: 250.4 cm/s, SR: 9.8 Hz, VC: 0.54) and BPs (PSV: 232.4 cm/s, SR: 12.5 Hz, VC: 0.61), with MPs having slower SR (p < 0.01). None of the implants had normal flow (p < 0.0001). In conclusion, VFI can provide new flow parameters for AS and implant assessment.
Collapse
Affiliation(s)
- Kristoffer Lindskov Hansen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
| | - Hasse Møller-Sørensen
- Department of Cardiothoracic Anesthesiology, Copenhagen University Hospital, Denmark
| | | | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, DTU Elektro, Technical University of Denmark, Denmark
| | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
7
|
Hansen KL, Hansen PM, Ewertsen C, Lönn L, Jensen JA, Nielsen MB. Vector Flow Imaging Compared with Digital Subtraction Angiography for Stenosis Assessment in the Superficial Femoral Artery - A Study of Vector Concentration, Velocity Ratio and Stenosis Degree Percentage. Ultrasound Int Open 2019; 5:E53-E59. [PMID: 30886943 PMCID: PMC6420338 DOI: 10.1055/a-0853-2002] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Revised: 12/01/2018] [Accepted: 01/29/2019] [Indexed: 10/27/2022] Open
Abstract
Purpose Stenosis of the superficial femoral artery (SFA) induces complex blood flow with increased velocities. Disease assessment is performed with Doppler ultrasound and digital subtraction angiography (DSA), but Doppler ultrasound is limited by angle dependency and DSA by ionizing radiation. An alternative is the vector flow imaging method based on transverse oscillation (TO), an angle-independent vector velocity technique using ultrasound. In this study, flow complexity and velocity measured with TO were compared with DSA for the assessment of stenosis in the SFA. Materials and Methods The vector concentration, a measure of flow complexity, and the velocity ratio obtained from the stenosis and a disease-free adjacent vessel segment, were estimated with TO in 11 patients with a total of 16 stenoses of the SFA. TO data were compared with the corresponding stenosis degree percentage obtained with DSA. Results The correlation between the vector concentration and DSA was very strong (R=0.93; p<0.001; 95% confidence interval (CI): 0.81-0.98), while only moderate for velocity ratio and DSA (R=0.50; p<0.07; 95% CI: 0.00-0.80). The correlation coefficients that were found were significantly different (p<0.005) without overlapping CI. Conclusion The study indicated that flow changes in the SFA induced by stenosis can be quantified with TO, and that stenosis grading may be improved by estimation of flow complexity instead of velocity ratio. TO is a potential diagnostic tool for the assessment of atherosclerosis and peripheral arterial disease.
Collapse
Affiliation(s)
- Kristoffer Lindskov Hansen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Copenhagen, Denmark.,Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Peter Møller Hansen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Copenhagen, Denmark
| | - Caroline Ewertsen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Copenhagen, Denmark.,Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Lars Lönn
- Department of Diagnostic Radiology, Copenhagen University Hospital, Copenhagen, Denmark.,Department of Vascular Surgery, Copenhagen University Hospital, Copenhagen, Denmark
| | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Technical University of Denmark, DTU Elektro, Kgs. Lyngby, Denmark
| | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, Copenhagen University Hospital, Copenhagen, Denmark.,Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
8
|
Abstract
In children with congenital heart defects, Doppler ultrasound is the standard, bedside imaging modality. However, precise characterization of blood flow is challenging due to angle-dependent and one-dimensional velocity estimation. Contrast agent free Vector Flow Imaging is a new ultrasound technology that enables angle-independent visualization of the detailed flow field. Two piglets, one with normal cardiac anatomy and one with congenital heart disease comprised of valvular pulmonary stenosis, a dilated main pulmonary artery, and an incomplete atrioventricular canal defect, were imaged transthoracically and epicardially using a BK Ultrasound bk5000 with built-in vector flow imaging and a 5MHz linear probe. Subsequently, two children, one with normal cardiac anatomy and one with congenital heart disease comprised of aortic valve stenosis and coarctation of the aorta were imaged transthoracically. Transthoracic two-dimensional echocardiography and vector flow imaging were readily performed in both animals and were limited only by the geometry of the porcine thorax. In addition, transthoracic vector flow imaging was successfully performed in both children, and abnormal flow secondary to cardiac anomalies was visible. Adequate penetration was obtained to a depth of 6.5 cm. Our group has previously demonstrated for the first time that transthoracic vector flow imaging echocardiography is feasible and practicable in pediatric-sized patients, and this paper describes examples of these concepts and in-depth comparisons with traditional imaging modalities. This paper demonstrates that commercially available vector flow imaging technology can be utilized in pediatric cardiac applications as a bedside transthoracic imaging modality, providing advanced detail of blood flow patterns within the cardiac chambers, across valves, and in the great arteries.
Collapse
|
9
|
Di Ianni T, Hansen KL, Villagomez Hoyos CA, Moshavegh R, Nielsen MB, Jensen JA. Portable Vector Flow Imaging Compared With Spectral Doppler Ultrasonography. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:453-462. [PMID: 30281442 DOI: 10.1109/tuffc.2018.2872508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In this study, a vector flow imaging (VFI) method developed for a portable ultrasound scanner was used for estimating peak velocity values and variation in beam-to-flow angle over the cardiac cycle in vivo on healthy volunteers. Peak-systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index (RI) measured with VFI were compared to spectral Doppler ultrasonography (SDU). Seventeen healthy volunteers were scanned on the left and right common carotid arteries (CCAs). The standard deviation (SD) of VFI measurements averaged over the cardiac cycle was 7.3% for the magnitude and 3.84° for the angle. Bland-Altman plots showed a positive bias for the PSV measured with SDU (mean difference: 0.31 ms -1 ), and Pearson correlation analysis showed a highly significant correlation ( r = 0.6 ; ). A slightly positive bias was found for EDV and RI measured with SDU (mean difference: 0.08 ms -1 and -0.01 ms -1 , respectively). However, the correlation was low and not significant. The beam-to-flow angle was estimated over the systolic part of the cardiac cycle, and its variations were for all measurements larger than the precision of the angle estimation. The range spanned deviations from -25.2° (-6.0 SD) to 23.7° (4.2 SD) with an average deviation from -15.2° to 9.7°. This can significantly affect PSV values measured by SDU as the beam-to-flow angle is not constant and not aligned with the vessel surface. The study demonstrates that the proposed VFI method can be used in vivo for the measurement of PSV in the CCAs, and that angle variations across the cardiac cycle can lead to significant errors in SDU velocity estimates.
Collapse
|
10
|
Bechsgaard T, Hansen KL, Brandt A, Moshavegh R, Forman JL, Føgh P, Klitfod L, Bækgaard N, Lönn L, Jensen JA, Nielsen MB. Evaluation of Peak Reflux Velocities with Vector Flow Imaging and Spectral Doppler Ultrasound in Varicose Veins. Ultrasound Int Open 2018; 4:E91-E98. [PMID: 30276359 PMCID: PMC6162191 DOI: 10.1055/a-0643-4430] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 04/24/2018] [Accepted: 05/17/2018] [Indexed: 10/29/2022] Open
Abstract
Purpose Spectral Doppler ultrasound (SDUS) is used for quantifying reflux in lower extremity varicose veins. The technique is angle-dependent opposed to the new angle-independent Vector Flow Imaging (VFI) method. The aim of this study was to compare peak reflux velocities obtained with VFI and SDUS in patients with chronic venous disease, i. e., pathological retrograde blood flow caused by incompetent venous valves. Materials and Methods 64 patients with chronic venous disease were scanned with VFI and SDUS in the great or the small saphenous vein, and reflux velocities were compared to three assessment tools for chronic venous disease. A flow rig was used to assess the accuracy and precision of the two methods. Results The mean peak reflux velocities differed significantly (VFI: 47.4 cm/s vs. SDUS: 62.0 cm/s, p<0.001). No difference in absolute precision (p=0.18) nor relative precision (p=0.79) was found. No correlation to disease severity, according to assessment tools, was found for peak reflux velocities obtained with either method. In vitro, VFI was more accurate but equally precise when compared to SDUS. Conclusion Both VFI and SDUS detected the pathologic retrograde flow in varicose veins but measured different reflux velocities with equal precision. VFI may play a role in evaluating venous disease in the future.
Collapse
Affiliation(s)
| | | | - Andreas Brandt
- Copenhagen University Hospital Rigshospitalet, Department of Diagnostic Radiology, 2100 Copenhagen Oe, Denmark
| | - Ramin Moshavegh
- The Technical University of Denmark, Department of Electrical Engineering Center for Fast Ultrasound Imaging, 2800 Kgs. Lyngby, Denmark
| | - Julie Lyng Forman
- Copenhagen University, Department of Public Health Section of Biostatistics, 1014 Copenhagen K, Denmark
| | - Pia Føgh
- Copenhagen University Hospital Rigshospitalet, Department of Vascular Surgery Herlev & Gentofte Hospital, 2900 Hellerup, Denmark
| | - Lotte Klitfod
- Copenhagen University Hospital Rigshospitalet, Department of Vascular Surgery Herlev & Gentofte Hospital, 2900 Hellerup, Denmark
| | - Niels Bækgaard
- Copenhagen University Hospital Rigshospitalet, Department of Vascular Surgery Herlev & Gentofte Hospital, 2900 Hellerup, Denmark
| | - Lars Lönn
- Rigshospitalet, Copenhagen, DK, Radiology, Copenhagen, Denmark
| | - Jørgen Arendt Jensen
- Technical University of Denmark, Department of Electrical Engineering Center for Fast Ultrasound Imaging, 2800 Kgs. Lyngby, Denmark
| | | |
Collapse
|
11
|
Bechsgaard T, Hansen KL, Brandt AH, Moshavegh R, Forman JL, Føgh P, Klitfod L, Bækgaard N, Lönn L, Nielsen MB, Jensen JA. Respiratory variability of peak velocities in the common femoral vein estimated with vector flow imaging and Doppler ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1941-1950. [PMID: 29960752 DOI: 10.1016/j.ultrasmedbio.2018.05.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Revised: 04/26/2018] [Accepted: 05/04/2018] [Indexed: 06/08/2023]
Abstract
Respiratory variability of peak velocities (RVPV) in the common femoral vein measured with ultrasound can reveal venous outflow obstruction. Pulse wave (PW) Doppler is the gold standard for venous velocity estimation of the lower extremities. PW Doppler measurements are angle dependent, whereas vector flow imaging (VFI) can yield angle-independent measures. The hypothesis of the present study was that VFI can provide RVPV estimations without the angle dependency of PW Doppler for an improved venous disease assessment. Sixty-seven patients with symptomatic chronic venous disease were included in the study. On average, VFI measured a lower RVPV than PW Doppler (VFI: 14.11 cm/s; PW: 17.32 cm/s, p = 0.002) with a non-significant improved precision compared with PW Doppler (VFI: 21.09%; PW: 26.49%, p = 0.08). In a flow phantom, VFI had improved accuracy (p < 0.01) and equal precision compared with PW Doppler. The study indicated that VFI can characterize the hemodynamic fluctuations in the common femoral vein.
Collapse
Affiliation(s)
- Thor Bechsgaard
- Department of Diagnostic Radiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen Ø, Denmark.
| | - Kristoffer Lindskov Hansen
- Department of Diagnostic Radiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen Ø, Denmark
| | - Andreas Hjelm Brandt
- Department of Diagnostic Radiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen Ø, Denmark
| | - Ramin Moshavegh
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Julie Lyng Forman
- Section of Biostatistics, Department of Public Health, Copenhagen University, Copenhagen K, Denmark
| | - Pia Føgh
- Department of Vascular Surgery, Rigshospitalet & Gentofte Hospital - Copenhagen University Hospital, Hellerup, Denmark
| | - Lotte Klitfod
- Department of Vascular Surgery, Rigshospitalet & Gentofte Hospital - Copenhagen University Hospital, Hellerup, Denmark
| | - Niels Bækgaard
- Department of Vascular Surgery, Rigshospitalet & Gentofte Hospital - Copenhagen University Hospital, Hellerup, Denmark
| | - Lars Lönn
- Department of Diagnostic Radiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen Ø, Denmark
| | - Michael Bachmann Nielsen
- Department of Diagnostic Radiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen Ø, Denmark
| | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| |
Collapse
|
12
|
Brandt AH, Hansen KL, Ewertsen C, Holbek S, Olesen JB, Moshavegh R, Thomsen C, Jensen JA, Nielsen MB. A Comparison Study of Vector Velocity, Spectral Doppler and Magnetic Resonance of Blood Flow in the Common Carotid Artery. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1751-1761. [PMID: 29804906 DOI: 10.1016/j.ultrasmedbio.2018.05.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Revised: 04/26/2018] [Accepted: 05/01/2018] [Indexed: 06/08/2023]
Abstract
Magnetic resonance phase contrast angiography (MRA) is the gold standard for blood flow evaluation. Spectral Doppler ultrasound (SDU) is the first clinical choice, although the method is angle dependent. Vector flow imaging (VFI) is an angle-independent ultrasound method. The aim of the study was to compare VFI- and SDU-estimated peak systolic velocities (PSV) of the common carotid artery (CCA) with PSV obtained by MRA. Furthermore, intra- and inter-observer agreement was determined. MRA estimates were significantly different from SDU estimates (left CCA: p < 0.001, right CCA: p < 0.001), but not from VFI estimates (left CCA: p = 0.28, right CCA: p = 0.18). VFI measured lower PSV in both CCAs compared with SDU (p < 0.001) with improved precision (VFI: left: 24%, right: 18%; SDU: left 38%, right: 23%). Intra- and inter-observer agreement was almost perfect for VFI and SDU (inter-observer correlation coefficient: VFI 0.88, SDU 0.91; intra-observer correlation coefficient: VFI 0.96, SDU 0.97). VFI is more accurate than SDU in evaluating PSV compared with MRA.
Collapse
Affiliation(s)
- Andreas Hjelm Brandt
- Department of Radiology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
| | | | - Caroline Ewertsen
- Department of Radiology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Simon Holbek
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Jacob Bjerring Olesen
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Ramin Moshavegh
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Carsten Thomsen
- Department of Radiology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark; Department of Radiology, Zealand University Hospital Roskilde, Roskilde, Denmark
| | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | | |
Collapse
|
13
|
Holbek S, Hansen KL, Fogh N, Moshavegh R, Olesen JB, Nielsen MB, Jensen JA. Real-Time 2-D Phased Array Vector Flow Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1205-1213. [PMID: 29993373 DOI: 10.1109/tuffc.2018.2838518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Echocardiography examination of the blood flow is currently either restricted to 1-D techniques in real-time or experimental offline 2-D methods. This paper presents an implementation of transverse oscillation for real-time 2-D vector flow imaging (VFI) on a commercial BK Ultrasound scanner. A large field-of-view (FOV) sequence for studying flow dynamics at 11 frames per second (fps) and a sequence for studying peak systolic velocities (PSVs) with a narrow FOV at 36 fps were validated. The VFI sequences were validated in a flow rig with continuous laminar parabolic flow and in a pulsating flow pump system before being tested in vivo, where measurements were obtained on two healthy volunteers. Mean PSV from 11 cycles was 155 cms-1 with a precision of ±9.0% for the pulsating flow pump. In vivo, PSV estimated in the ascending aorta was 135 cms-1 ± 16.9% for eight cardiac cycles. Furthermore, in vivo flow dynamics of the left ventricle and in the ascending aorta were visualized. In conclusion, angle independent 2-D VFI on a phased array has been implemented in real time, and it is capable of providing quantitative and qualitative flow evaluations of both the complex and fully transverse flow.
Collapse
|