1
|
Pruijssen JT, Schreuder FHBM, Wilbers J, Kaanders JHAM, de Korte CL, Hansen HHG. Performance evaluation of commercial and non-commercial shear wave elastography implementations for vascular applications. ULTRASONICS 2024; 140:107312. [PMID: 38599075 DOI: 10.1016/j.ultras.2024.107312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 03/25/2024] [Accepted: 04/01/2024] [Indexed: 04/12/2024]
Abstract
BACKGROUND Shear wave elastography (SWE) is mainly used for stiffness estimation of large, homogeneous tissues, such as the liver and breasts. However, little is known about its accuracy and applicability in thin (∼0.5-2 mm) vessel walls. To identify possible performance differences among vendors, we quantified differences in measured wave velocities obtained by commercial SWE implementations of various vendors over different imaging depths in a vessel-mimicking phantom. For reference, we measured SWE values in the cylindrical inclusions and homogeneous background of a commercial SWE phantom. Additionally, we compared the accuracy between a research implementation and the commercially available clinical SWE on an Aixplorer ultrasound system in phantoms and in vivo in patients. METHODS SWE measurements were performed over varying depths (0-35 mm) using three ultrasound machines with four ultrasound probes in the homogeneous 20 kPa background and cylindrical targets of 10, 40, and 60 kPa of a multi-purpose phantom (CIRS-040GSE) and in the anterior and posterior wall of a homogeneous polyvinyl alcohol vessel-mimicking phantom. These phantom data, along with in vivo SWE data of carotid arteries in 23 patients with a (prior) head and neck neoplasm, were also acquired in the research and clinical mode of the Aixplorer ultrasound machine. Machine-specific estimated phantom stiffness values (CIRS phantom) or wave velocities (vessel phantom) over all depths were visualized, and the relative error to the reference values and inter-frame variability (interquartile range/median) were calculated. Correlations between SWE values and target/vessel wall depth were explored in phantoms and in vivo using Spearman's correlations. Differences in wave velocities between the anterior and posterior arterial wall were assessed with Wilcoxon signed-rank tests. Intra-class correlation coefficients were calculated for a sample of ten patients as a measure of intra- and interobserver reproducibility of SWE analyses in research and clinical mode. RESULTS There was a high variability in obtained SWE values among ultrasound machines, probes, and, in some cases, with depth. Compared to the homogeneous CIRS-background, this variation was more pronounced for the inclusions and the vessel-mimicking phantom. Furthermore, higher stiffnesses were generally underestimated. In the vessel-mimicking phantom, anterior wave velocities were (incorrectly) higher than posterior wave velocities (3.4-5.6 m/s versus 2.9-5.9 m/s, p ≤ 0.005 for 3/4 probes) and remarkably correlated with measurement depth for most machines (Spearman's ρ = -0.873-0.969, p < 0.001 for 3/4 probes). In the Aixplorer's research mode, this difference was smaller (3.3-3.9 m/s versus 3.2-3.6 m/s, p = 0.005) and values did not correlate with measurement depth (Spearman's ρ = 0.039-0.659, p ≥ 0.002). In vivo, wave velocities were higher in the posterior than the anterior vessel wall in research (left p = 0.001, right p < 0.001) but not in clinical mode (left: p = 0.114, right: p = 0.483). Yet, wave velocities correlated with vessel wall depth in clinical (Spearman's ρ = 0.574-0.698, p < 0.001) but not in research mode (Spearman's ρ = -0.080-0.466, p ≥ 0.003). CONCLUSIONS We observed more variation in SWE values among ultrasound machines and probes in tissue with high stiffness and thin-walled geometry than in low stiffness, homogeneous tissue. Together with a depth-correlation in some machines, where carotid arteries have a fixed location, this calls for caution in interpreting SWE results in clinical practice for vascular applications.
Collapse
Affiliation(s)
- Judith T Pruijssen
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud university medical center, Nijmegen, the Netherlands.
| | - Floris H B M Schreuder
- Department of Neurology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Joyce Wilbers
- Center of Expertise for Cancer Survivorship, Radboud university medical center, Nijmegen, the Netherlands
| | - Johannes H A M Kaanders
- Department of Radiation Oncology, Radboud university medical center, Nijmegen, the Netherlands
| | - Chris L de Korte
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud university medical center, Nijmegen, the Netherlands; Physics of Fluid Group, MESA+ Institute for Nanotechnology, and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands
| | - Hendrik H G Hansen
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud university medical center, Nijmegen, the Netherlands
| |
Collapse
|
2
|
Pruijssen JT, Fekkes S, Menssen J, de Korte CL, Hansen HH. Extending arterial stiffness assessment along the circumference using beam-steered ARFI and wave-tracking: A proof-of-principle study in phantoms and ex vivo. Comput Struct Biotechnol J 2023; 21:4288-4300. [PMID: 37701019 PMCID: PMC10493891 DOI: 10.1016/j.csbj.2023.08.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 08/23/2023] [Accepted: 08/25/2023] [Indexed: 09/14/2023] Open
Abstract
Background To fully quantify arterial wall and plaque stiffness, acoustic radiation force impulse (ARFI)-induced wave-tracking along the entire vessel circumference is desired. However, attenuation and guided wave behavior in thin vessel walls limits wave-tracking to short trajectories. This study investigated the potential of beam-steered ARFI and wave-tracking to extend group velocity estimation over a larger proportion of the circumference compared to conventional 0° ARFI-induced wave-tracking. Methods Seven vessel-mimicking polyvinyl alcohol cryogel phantoms with various dimensions and compositions and an ex vivo human carotid artery were imaged in a dedicated setup. For every 20⁰ phantom rotation, transverse group wave velocity measurements were performed with an Aixplorer Ultimate system and SL18-5 transducer using 0⁰/20⁰/-20⁰-angled ultrasound pushes. Transmural angular wave velocities were derived along 60⁰-trajectories. A 360⁰-angular velocity map was composed from the top-wall 60⁰-trajectories 0°-data, averaged over all physical phantom rotations (reference). For each phantom rotation, 360⁰-angular velocity maps were composed using 0°-data (0⁰-approach) or data from all angles (beam-steered approach). Percentages of rotations with visible waves and relative angular velocity errors compared to the reference map as function of the circumferential angle were determined for both approaches. Results Reference 360°-angular velocity maps could be derived for all samples, representing their stiffness. Beam-steering decreased the proportion of the circumference where waves were untraceable by 20% in phantoms and 10% ex vivo, mainly at 0° push locations. Relative errors were similar for both approaches (phantoms: 10-15%, ex vivo: 15-35%). Conclusion Beam-steering enables wave-tracking along a higher proportion of the wall circumference than 0⁰ ARFI-induced wave-tracking.
Collapse
Affiliation(s)
- Judith T. Pruijssen
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Stein Fekkes
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Jan Menssen
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Chris L. de Korte
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud University Medical Center, Nijmegen, the Netherlands
- Physics of Fluid Group, MESA+ Institute for Nanotechnology, and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands
| | - Hendrik H.G. Hansen
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud University Medical Center, Nijmegen, the Netherlands
| |
Collapse
|
3
|
Wang Y, Lee WN. Non-Invasive Estimation of Localized Dynamic Luminal Pressure Change by Ultrasound Elastography in Arteries With Normal and Abnormal Geometries. IEEE Trans Biomed Eng 2021; 68:1627-1637. [DOI: 10.1109/tbme.2020.3028186] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
4
|
Pruijssen JT, de Korte CL, Voss I, Hansen HHG. Vascular Shear Wave Elastography in Atherosclerotic Arteries: A Systematic Review. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2145-2163. [PMID: 32620385 DOI: 10.1016/j.ultrasmedbio.2020.05.013] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 05/15/2020] [Accepted: 05/15/2020] [Indexed: 06/11/2023]
Abstract
Ischemic stroke is a leading cause of death and disability worldwide, so adequate prevention strategies are crucial. However, current stroke risk stratification is based on epidemiologic studies and is still suboptimal for individual patients. The aim of this systematic review was to provide a literature overview on the feasibility and diagnostic value of vascular shear wave elastography (SWE) using ultrasound (US) in (mimicked) human and non-human arteries affected by different stages of atherosclerotic diseases or diseases related to atherosclerosis. An online search was conducted on Pubmed, Embase, Web of Science and IEEE databases to identify studies using US SWE for the assessment of vascular elasticity. A quality assessment was performed using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) checklist, and relevant data were extracted. A total of 19 studies were included: 10 with human patients and 9 with non-human subjects (i.e., [excised] animal arteries and polyvinyl alcohol phantoms). All studies revealed the feasibility of using US SWE to assess individually stiffness of the arterial wall and plaques. Quantitative elasticity values were highly variable between studies. However, within studies, SWE could detect statistically significant elasticity differences in patient/subject characteristics and could distinguish different plaque types with good reproducibility. US SWE, with its unique ability to assess the elasticity of the vessel wall and plaque throughout the cardiac cycle, might be a good candidate to improve stroke risk stratification. However, more clinical studies have to be performed to assess this technique's exact clinical value.
Collapse
Affiliation(s)
- Judith T Pruijssen
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
| | - Chris L de Korte
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands; Physics of Fluid Group, MESA+ Institute for Nanotechnology, and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
| | - Iona Voss
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Hendrik H G Hansen
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
5
|
Dong J, Zhang Y, Lee WN. Walled vessel-mimicking phantom for ultrasound imaging using 3D printing with a water-soluble filament: design principle, fluid-structure interaction (FSI) simulation, and experimental validation. Phys Med Biol 2020; 65:085006. [PMID: 32106096 DOI: 10.1088/1361-6560/ab7abf] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
The geometry and stiffness of a vessel are pertinent to blood dynamics and vessel wall mechanical behavior and may alter in diseased conditions. Ultrasound-based ultrafast Doppler (uDoppler) imaging and shear wave imaging (SWI) techniques have been extensively exploited for the assessment of vascular hemodynamics and mechanics. Their performance is conventionally validated on vessel-mimicking phantoms (VMPs) prior to their clinical use. Compared with commercial ones, customized VMPs are favored for research use because of their wider range of material properties, more complex lumen geometries, or wall structures. Fused deposition modeling (FDM) 3D printing technique with plastic filaments is a promising method for making VMPs with a complex vessel lumen. However, it may require a toxic solvent or a long dissolution time currently. In this paper, we present a safe, efficient and geometrically flexible method where FDM 3D printing with a water-soluble polyvinyl alcohol (PVA) filament is exploited to fabricate a walled three-branch VMP (VMP-I). As a key step in fabrication, to avoid dissolution of the PVA-printed vessel core by the solution of the tissue-mimicking material, paraffin wax was used for isolation. Paraffin wax is easy to coat (i.e. without any special equipment), of satisfactory thickness (∼0.1 mm), chemically stable, and easy to remove after fabrication, thus making the proposed method practicable for ultrasound imaging studies. VMP-I was examined by B-mode imaging and power Doppler imaging (PDI) to verify complete dissolution of PVA-printed vessel core in its lumen, confirming good fabrication quality. The flow velocities in VMP-I were estimated by uDoppler imaging with a -0.8% difference, and the shear wave propagation speeds for the same phantom were estimated by SWI with a -6.03% difference when compared with fluid-structure interaction (FSI) simulation results. A wall-less VMP of a scaled and simplified coronary arterial network (VMP-II) was additionally fabricated and examined to test the capability of the proposed method for a complex lumen geometry. The proposed fabrication method for customized VMPs is foreseen to facilitate the development of ultrasound imaging techniques for blood vessels.
Collapse
Affiliation(s)
- Jinping Dong
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong
| | | | | |
Collapse
|
6
|
Bernal M, Saldarriaga J, Cabeza C, Negreira C, Bustamante J, Brum J. Development and evaluation of anisotropic and nonlinear aortic models made from clinical images for in vitro experimentation. ACTA ACUST UNITED AC 2019; 64:165006. [DOI: 10.1088/1361-6560/ab2db5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
7
|
Wang Y, Li H, Guo Y, Lee WN. Bidirectional Ultrasound Elastographic Imaging Framework for Non-invasive Assessment of the Non-linear Behavior of a Physiologically Pressurized Artery. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1184-1196. [PMID: 30876671 DOI: 10.1016/j.ultrasmedbio.2019.01.014] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Revised: 01/10/2019] [Accepted: 01/15/2019] [Indexed: 06/09/2023]
Abstract
Studies of non-destructive bidirectional ultrasound assessment of non-linear mechanical behavior of the artery are scarce in the literature. We hereby propose derivation of a strain-shear modulus relationship as a new graphical diagnostic index using an ultrasound elastographic imaging framework, which encompasses our in-house bidirectional vascular guided wave imaging (VGWI) and ultrasound strain imaging (USI). This framework is used to assess arterial non-linearity in two orthogonal (i.e., longitudinal and circumferential) directions in the absence of non-invasive pressure measurement. Bidirectional VGWI estimates longitudinal (μL) and transverse (μT) shear moduli, whereas USI estimates radial strain (ɛr). Vessel-mimicking phantoms (with and without longitudinal pre-stretch) and in vitro porcine aortas under static and/or dynamic physiologic intraluminal pressure loads were examined. ɛr was found to be a suitable alternative to intraluminal pressure for representation of cyclic loading on the artery wall. Results revealed that μT values of all samples examined increased non-linearly with εr magnitude and more drastically than μL, whereas μL values of only the pre-stretched phantoms and aortas increased with ɛr magnitude. As a new graphical representation of arterial non-linearity and function, strain-shear modulus loops derived by the proposed framework over two consecutive dynamic loading cycles differentiated sample pre-conditions and corroborated direction-dependent non-linear mechanical behaviors of the aorta with high estimation repeatability.
Collapse
Affiliation(s)
- Yahua Wang
- Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong
| | - He Li
- Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong
| | - Yuexin Guo
- Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong
| | - Wei-Ning Lee
- Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong; Medical Engineering Programme, University of Hong Kong, Hong Kong.
| |
Collapse
|
8
|
Lee WN, Chang EJH, Guo Y, Wang Y. Experimental Investigation of Guided Wave Imaging in Thin Soft Media under Various Coupling Conditions. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:2821-2837. [PMID: 30241727 DOI: 10.1016/j.ultrasmedbio.2018.07.029] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 06/30/2018] [Accepted: 07/28/2018] [Indexed: 06/08/2023]
Abstract
Guided wave imaging for the artery remains in its infancy in clinical practice mainly because of complex arterial microstructure, hemodynamics and boundary conditions. Despite the theoretically known potential effect of the surrounding medium on guided wave propagation in thin media in non-destructive testing, experimental evidence pertaining to thin soft materials, such as the artery, is relatively scarce in the relevant literature. Therefore, this study first evaluated the propagating guided wave generated by acoustic radiation force in polyvinyl alcohol-based hydrogel plates differing in thickness and stiffness under various material coupling conditions (water and polyvinyl alcohol bulk). A thin-walled polyvinyl alcohol hollow cylindrical phantom coupled by softer gelatin-agar phantoms and an excised porcine aorta surrounded by water and pork belly were further examined. Guided waves in the thin structure and shear waves in the bulk media were captured by ultrafast ultrasound imaging, and guided wave dispersion as a function of the frequency-thickness product was analyzed using the zero-order anti-symmetric Lamb wave model to estimate the shear modulus of each thin medium studied. Results confirmed the deviated shear modulus estimates from the ground truth for thin plates, the thin-walled hollow cylindrical phantom and the porcine aorta bounded by stiffness-unmatched bulk medium. The findings indicated the need for (i) careful interpretation of estimated shear moduli of thin structure bounded by bulk media and (ii) a generalized guided wave model that takes into account the effect of coupling medium.
Collapse
Affiliation(s)
- Wei-Ning Lee
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Medical Engineering Programme, The University of Hong Kong, Hong Kong.
| | - Enoch Jing-Han Chang
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Medical Engineering Programme, The University of Hong Kong, Hong Kong
| | - Yuexin Guo
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong
| | - Yahua Wang
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong
| |
Collapse
|