1
|
Ji J, Tang E, Wang Y, Shi X. The Clinical Application of Superb Microvascular Imaging in Evaluating Thyroid Related Diseases: A Systematic Review. JOURNAL OF CLINICAL ULTRASOUND : JCU 2024. [PMID: 39391983 DOI: 10.1002/jcu.23863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2024] [Revised: 06/28/2024] [Accepted: 09/24/2024] [Indexed: 10/12/2024]
Abstract
This article reviews all published articles on the application of superb microvascular imaging (SMI) technique in thyroid related diseases before December 31, 2023. SMI, a recently developed ultrasound imaging modality, could display microvascular information by eliminating clutter and preserving low flow signals. Most studies used SMI to help diagnose malignant thyroid nodules and concluded that SMI performed better than color Doppler imaging and power Doppler imaging. At present, there is no consensus when depicting the morphology of vascularity of thyroid nodules (TNs). This problem may be solved by quantitative SMI which makes it possible to quantitatively evaluate the vascularity of TNs. SMI is also applied to evaluate cervical lymph node or thyroid inflammatory diseases. Although, SMI has some limitations, such as no standard for the normal perfusion patterns, and it has a broad application prospect in the diagnosis and management of thyroid related diseases.
Collapse
Affiliation(s)
- Jiaqi Ji
- Department of Ultrasound, Aerospace Center Hospital, Beijing, China
| | - Enyu Tang
- Department of Gynecologic Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Ya'ni Wang
- State Key Laboratory of Frigid Zone Cardiovascular Disease, Cardiovascular Research Institute and Department of Cardiology, General Hospital of Northern Theater Command, Shenyang, China
- Department of Cardiology, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Xinlong Shi
- Department of Internal Medicine 1, Friedrich-Alexander University (FAU) Erlangen-Nürnberg and Universitätsklinikum Erlangen, Erlangen, Germany
| |
Collapse
|
2
|
Mahmoud SAE, Enaba ME, Shareef MM, Hafez YM, Abbas I. Comparison the accuracy of thyroid sono-elastography vs. ultrasound-guided fine needle aspiration cytology with thyroid malignancy diagnosis histopathology. Endocr Regul 2024; 58:129-137. [PMID: 38861538 DOI: 10.2478/enr-2024-0014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/13/2024] Open
Abstract
Objective. The intend of the present study was to assess the diagnostic performance of strain elastography in investigating the thyroid nodule malignancy taking the surgical biopsy as a gold standard reference test. Methods. The study included 120 patients with 123 thyroid nodules, of which 67 had total thyroidectomy. The American College of Radiology Thyroid Imaging Reporting and Data Systems (ACR-TIRADS) were evaluated for all nodules. All suspicious nodules were referred for a fine needle aspiration cytology (FNAC) if they fulfilled the required size. Strain elastography was performed for each suspicious nodule. Ultrasound-guided FNAC was performed for all suspicious nodules. Total thyroidectomy was performed in those whom the suspicious nodules were proven by FNAC. Results. Strain ratio had a sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of 84%, 81%, 95%, 85%, and 84%, respectively, with a cut point 1.96. Elasticity score had a sensitivity, specificity, PPV, NPV, and diagnostic accuracy of 100%, 80%, 95%, 85% and 87%, respectively, with a cut point 0.96. The elasticity score had a statistically significantly odds ratio for detecting the benignity 3.9 C. I (1.6-9.3). Conclusion. Strain elastography has a high diagnostic performance in detecting the malignant as well as benign nodules, thus it can limit the rate of unneeded FNAC or surgery especially among B3 and B4 groups with indeterminate cytology.
Collapse
Affiliation(s)
- Sarah Abd Elmageed Mahmoud
- Internal Medicine Department, Tanta University Hospital, Faculty of Medicine, University of Tanta, Tanta, AL Gharbia, Egypt
| | - Mohamed Elsayed Enaba
- Internal Medicine Department, Tanta University Hospital, Faculty of Medicine, University of Tanta, Tanta, AL Gharbia, Egypt
| | - Mohamed Moustafa Shareef
- Pathology Department, Tanta University Hospital, Faculty of Medicine, University of Tanta, Tanta, AL Gharbia, Egypt
| | - Yasser Moustafa Hafez
- Pathology Department, Tanta University Hospital, Faculty of Medicine, University of Tanta, Tanta, AL Gharbia, Egypt
| | - Ibrahim Abbas
- Diagnostic Radiology Department, Faculty of Medicine, University of Tanta, Tanta, AL Gharbia, Egypt
| |
Collapse
|
3
|
Javed N, Ghazanfar H, Jyala A, Patel H. Associations of Real-Time Ultrasound and Strain and Shear Wave Elastography with Gastrointestinal Organs: A Systematic Review. Diagnostics (Basel) 2023; 13:3302. [PMID: 37958199 PMCID: PMC10649379 DOI: 10.3390/diagnostics13213302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 10/18/2023] [Accepted: 10/24/2023] [Indexed: 11/15/2023] Open
Abstract
Ultrasound elastography is gaining attention for its diagnostic potential across various medical fields, and its physical properties make it valuable in modern clinical medicine. However, its specific attributes, especially in the context of recent medical advancements, remain relatively unexplored. This study aimed to identify instrument-specific characteristics and applications of real-time ultrasound elastography, shear wave elastography, and strain elastography, particularly within gastroenterology. Following PRISMA guidelines, the study examined elastography articles on databases like PubMed, resulting in 78 included articles. Data on patient demographics, organ involvement, specificity, sensitivity, accuracy, positive predictive value, and negative predictive value were extracted. Statistical analysis involved SPSS version 21, with significance set at p < 0.05. The majority of patients were male (50.50%), with a mean age of 42.73 ± 4.41 years. Shear wave elastography was the most prevalent technique (48.7%), and liver investigations were predominant in gastroenterology (34.6%). Gastrointestinal applications showed higher sensitivity, positive predictive value, and negative predictive values (p < 0.05) but lower specificity (p < 0.05). Real-time ultrasound elastography exhibited increased specificity, accuracy, and predictive values (p < 0.05). Ultrasound elastography appears more accurate and effective in gastroenterological settings. Nonetheless, its performance depends on instrument-specific and operator-dependent factors. While promising, further studies are necessary to ascertain optimal utilization in both gastrointestinal and non-gastrointestinal conditions.
Collapse
Affiliation(s)
- Nismat Javed
- Department of Internal Medicine, BronxCare Health System, Bronx, NY 10457, USA;
| | - Haider Ghazanfar
- Department of Gastroenterology, BronxCare Health System, Bronx, NY 10457, USA; (H.G.); (A.J.)
| | - Abhilasha Jyala
- Department of Gastroenterology, BronxCare Health System, Bronx, NY 10457, USA; (H.G.); (A.J.)
| | - Harish Patel
- Department of Gastroenterology, BronxCare Health System, Bronx, NY 10457, USA; (H.G.); (A.J.)
| |
Collapse
|
4
|
Jiang L, Zhang D, Chen YN, Yu XJ, Pan MF, Lian L. The value of conventional ultrasound combined with superb microvascular imaging and color Doppler flow imaging in the diagnosis of thyroid malignant nodules: a systematic review and meta-analysis. Front Endocrinol (Lausanne) 2023; 14:1182259. [PMID: 37415660 PMCID: PMC10321595 DOI: 10.3389/fendo.2023.1182259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 05/30/2023] [Indexed: 07/08/2023] Open
Abstract
Purpose To evaluate and compare the value of conventional ultrasound-based superb microvascular imaging (SMI) and color Doppler flow imaging (CDFI) in the diagnosis of malignant thyroid nodule by meta-analysis. Methods The literature included in the Cochrane Library, PubMed, and Embase were searched by using " superb microvascular imaging (SMI), color Doppler flow imaging (CDFI), ultrasound, thyroid nodules" as the keywords from inception through February 1, 2023. According to the inclusion and exclusion criteria, the clinical studies using SMI and CDFI to diagnose thyroid nodules were selected, and histopathology of thyroid nodules was used as reference standard. The diagnostic accuracy research quality assessment tool (QUADAS-2) was used to evaluate the quality of included literature, and the Review Manager 5.4 was used to make the quality evaluation chart. The heterogeneity test was performed on the literature that met the requirements, the combined sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were pooled, and a comprehensive ROC curve analysis was performed. Meta-DiSc version 1.4, StataSE 12, and Review Manager 5.4 software were used. Results Finally, 13 studies were included in this meta-analysis. A total of 815 thyroid malignant nodules were assessed. All thyroid nodules were histologically confirmed after SMI or CDFI. The combined sensitivity, specificity, PLR, NLR, DOR, and area under the SROC curve of SMI for the diagnosis of malignant thyroid nodules were 0.80(95%CI: 0.77-0.83), 0.79(95%CI: 0.77-0.82), 4.37(95%CI: 3.0-6.36), 0.23(95%CI: 0.15-0.35), 22.29(95%CI: 12.18-40.78), and 0.8944, respectively; the corresponding values of CDFI were 0.62(95%CI: 0.57-0.67), 0.81(95%CI: 0.78-0.85), 3.33(95%CI: 2.18-5.07), 0.41(95%CI: 0.27-0.64), 8.93(95%CI: 3.96-20.16), and 0.8498. Deek funnel pattern showed no significant publication bias. Conclusion The diagnostic efficiency of SMI for malignant thyroid nodules is better than CDFI, and SMI technology can provide significantly more information on vascularity, make up for the deficiency of CDFI, and has better clinical application value. Systematic review registration https://www.crd.york.ac.uk/PROSPERO, identifier CRD42023402064.
Collapse
Affiliation(s)
- Li Jiang
- Medical College, Yangzhou University, Yangzhou, Jiangsu, China
- Department of Ultrasound, Suzhou Xiangcheng People’s Hospital, Jiangsu, China
| | - Dian Zhang
- Department of Ultrasound, Suzhou Xiangcheng People’s Hospital, Jiangsu, China
| | - Yue-Nan Chen
- Department of Ultrasound, Suzhou Xiangcheng People’s Hospital, Jiangsu, China
| | - Xue-Juan Yu
- Department of Ultrasound, Suzhou Xiangcheng People’s Hospital, Jiangsu, China
| | - Mei-Fang Pan
- Department of Ultrasound, Suzhou Xiangcheng People’s Hospital, Jiangsu, China
| | - Lian Lian
- Medical College, Yangzhou University, Yangzhou, Jiangsu, China
- Department of Oncology, Suzhou Xiangcheng People’s Hospital, Jiangsu, China
| |
Collapse
|
5
|
Diagnostic Value of AngioPLUS Microvascular Imaging in Thyroid Nodule Diagnosis Using Quantitative and Qualitative Vascularity Grading. Biomedicines 2022; 10:biomedicines10071554. [PMID: 35884858 PMCID: PMC9313421 DOI: 10.3390/biomedicines10071554] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 06/27/2022] [Accepted: 06/27/2022] [Indexed: 11/30/2022] Open
Abstract
This study investigated the diagnostic value of the Angio Planewave Ultrasensitive (AngioPLUS) Doppler ultrasound in improving the efficacy of grey scale ultrasound in thyroid nodule diagnosis. The EU TIRADS was used for the grey scale ultrasound assessment of 94 thyroid nodules. conventional Doppler and AngioPLUS Doppler ultrasound images were evaluated using qualitative vascularity grading, where predominant central vascularity indicated malignancy-suspicion, and quantitative regional vascularity assessment, where predominant peripheral vascularity using a ratio vascularity index (RVI) of > 1 indicated benign disease. Diagnostic performance outcomes of sole and combination approaches were calculated based on final pathologic results. Using sole EU TIRADS and AngioPLUS + power Doppler imaging (APDI) based on qualitative vascularity and RVI, the results were a sensitivity of 83.3% vs. 83.3 vs. 66.7% and a specificity of 50% vs. 81.3% vs. 73.4, respectively. EU TIRADS combined with APDI significantly improved the specificity using both qualitative vascularity and RVI assessment approaches (84.4% and 81%, respectively, p < 0.05); and slightly reduced the sensitivity (76.7% and 58.1%). For cytologically-equivocal thyroid nodules, the combination approach using qualitative vascularity assessment outperformed the EU TIRADS (sensitivity: both were 88.9%; specificity: 77.4% vs. 38.7%, p < 0.05; and AUROC: 0.83 vs. 0.62, p < 0.05). APDI combined with EU TIRADS is diagnostically efficient in stratifying thyroid nodules, particularly cytologically-equivocal nodules.
Collapse
|
6
|
Wang M, Wang X, Zhang H. Grayscale, subjective color Doppler, combined grayscale with subjective color Doppler in predicting thyroid carcinoma: a retrospective analysis. Braz J Otorhinolaryngol 2022; 88:220-227. [PMID: 32727669 PMCID: PMC9422397 DOI: 10.1016/j.bjorl.2020.05.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Accepted: 05/24/2020] [Indexed: 11/25/2022] Open
Abstract
Introduction Fine needle aspiration cytology is preferred for thyroid nodules preoperatively, but has disadvantages of false-negative and false-positive results. Objective To compare the diagnostic performance of grayscale ultrasound, subjective color Doppler ultrasound, and combined features of grayscale ultrasound and subjective color Doppler ultrasound in predicting thyroid carcinoma, using results of the fine needle aspiration cytology as the reference standard. Methods Data from gray-scale ultrasound images, subjective color Doppler ultrasound images, and the fine needle aspiration cytology of 325 nodules of 250 patients (age ≥ 18 years) were collected and analyzed. Hypo-echogenicity than adjacent strap muscle, micro-lobulated or irregular margins, micro- or mixed calcifications, and taller-than-wide shapes were considered as a suspicious malignant nodule in grayscale ultrasound. Marked vascularity was considered as a suspicious malignant nodule in color Doppler ultrasound. The Bethesda system for classification of thyroid nodules was used for cytopathology. Results With respect to the results of fine-needle aspiration cytology for detecting suspicious malignant nodules, for grayscale ultrasound, subjective color Doppler ultrasound, and combined gray-scale with subjective color Doppler ultrasound, sensitivities were 0.564, 0.600 and 0.691, respectively and accuracies were 0.926, 0.919 and 0.959, respectively. Suspicious malignant nodules detectability for grayscale ultrasound, subjective color Doppler ultrasound, and combined gray-scale with subjective color Doppler ultrasound were 0.09–0.56 diagnostic confidence, 0.08–0.61 diagnostic confidence, and 0.063–0.7 diagnostic confidence, respectively. Conclusions The combined gray-scale with subjective color Doppler ultrasound-guided fine-needle aspiration biopsies are recommended for the diagnosis of thyroid carcinoma. Level of Evidence: III.
Collapse
Affiliation(s)
- Minxin Wang
- Weihai Central Hospital, Department of Ultrasound, Shandong, China
| | - Xiaoting Wang
- Weihai Central Hospital, Department of Ultrasound, Shandong, China
| | - Hongsheng Zhang
- Weihai Central Hospital, Department of Imaging, Shandong, China.
| |
Collapse
|
7
|
Zhang WB, Deng WF, Mao L, He BL, Liu H, Chen J, Liu Y, Qi TY. Comparison of diagnostic value of SWE, FNA and BRAF gene detection in ACR TI-RADS 4 and 5 thyroid nodules. Clin Hemorheol Microcirc 2022; 81:13-21. [PMID: 35068450 DOI: 10.3233/ch-211280] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVES: To compare the diagnostic value of shear wave elastography (SWE), fine needle aspiration (FNA) and BRAF gene detection (BRAFV600E gene mutation detection) in ACR TI-RADS 4 and 5 thyroid nodules. METHODS: SWE images, FNA cytological results and BRAF detection results of ACR TI-RADS 4 and 5 thyroid nodules confirmed by pathology were analyzed retrospectively. The receiver operating characteristic (ROC) curve was drawn to determine the best cutoff value of SWE Emax. In the combined diagnosis of SWE, FNA and BRAF, firstly, the nodules with BRAF gene mutation were included in the positive ones, secondly, the nodules with benign and malignant FNA were included in the FNA + SWE or FNA + SWE + BRAF negative and positive ones respectively, finally, for FNA uncertain nodules: those whose SWE Emax were less than or equal to the cutoff value were included in FNA + SWE or FNA + SWE + BRAF negative ones, and those whose SWE Emax were greater than the cutoff value were included in positive ones. The diagnostic efficacy of SWE, FNA, SWE + FNA, FNA + BRAF and their combination in ACR TI-RADS 4 and 5 thyroid nodules were compared. RESULTS: The ROC curve showed that the best cutoff value of SWE Emax was 40.9 kpa, and the area under ROC curve (AUC) was 0.842 (0.800∼0.885). The sensitivity, specificity and accuracy of SWE were 76.3% (270/354), 75.5% (80/106) and 76.1% (350/460), respectively. The sensitivity, specificity and accuracy of FNA were 58.2% (206/354), 88.7% (94/106) and 65.2(300/460), respectively. The sensitivity, specificity and accuracy of FNA + BRAF were 95.5% (338/354), 88.7% (94/106) and 93.9% (432/460), respectively. The sensitivity, specificity and accuracy of SWE + FNA were 85.9% (304/354), 98.1% (104/106) and 88.7% (408/460), respectively. The sensitivity, specificity and accuracy of SWE + FNA + BRAF were 98.3% (348/354), 98.1% (104/106) and 98.3% (452/460), respectively. For the diagnostic accuracy, SWE + FNA + BRAF > FNA + BRAF > FNA + SWE > SWE > FNA, the difference was statistically significant (all P > 0.05). CONCLUSIONS: For ACR TI-RADS 4 and 5 thyroid nodules, SWE and FNA have high diagnostic efficiency. For the diagnostic accuracy, FNA + BRAF is better than FNA + SWE. FNA combination with BRAF gene detection further improves the diagnostic sensitivity and accuracy of FNA. The combined application of the three is the best.
Collapse
Affiliation(s)
- Wei-Bing Zhang
- Department of Medical Ultrasound, Jiangsu Provincial Corps Hospital, Chinese People’s Armed Police Forces, Yangzhou, China
| | - Wen-Fang Deng
- Department of Surgery, Subei people’s Hospital of Jiangsu Province, Yangzhou, China
| | - Lun Mao
- Department of Medical Ultrasound, Jiangsu Provincial Corps Hospital, Chinese People’s Armed Police Forces, Yangzhou, China
| | - Bei-Li He
- Department of Medical Ultrasound, Jiangsu Provincial Corps Hospital, Chinese People’s Armed Police Forces, Yangzhou, China
| | - Hua Liu
- Department of Medical Ultrasound, Jiangsu Provincial Corps Hospital, Chinese People’s Armed Police Forces, Yangzhou, China
| | - Jian Chen
- Department of Medical Ultrasound, Jiangsu Provincial Corps Hospital, Chinese People’s Armed Police Forces, Yangzhou, China
| | - Yu Liu
- Department of Medical Ultrasound, Jiangsu Provincial Corps Hospital, Chinese People’s Armed Police Forces, Yangzhou, China
| | - Ting-Yue Qi
- Department of Ultrasound, Medical Imaging Center, Affiliated Hospital of Yangzhou University, Yangzhou, China
| |
Collapse
|
8
|
Petersen M, Schenke SA, Firla J, Croner RS, Kreissl MC. Shear Wave Elastography and Thyroid Imaging Reporting and Data System (TIRADS) for the Risk Stratification of Thyroid Nodules-Results of a Prospective Study. Diagnostics (Basel) 2022; 12:diagnostics12010109. [PMID: 35054275 PMCID: PMC8774661 DOI: 10.3390/diagnostics12010109] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Revised: 12/12/2021] [Accepted: 12/29/2021] [Indexed: 12/13/2022] Open
Abstract
Purpose: To compare the diagnostic performance of thyroid imaging reporting and data system (TIRADS) in combination with shear wave elastography (SWE) for the assessment of thyroid nodules. Methods: A prospective study was conducted with the following inclusion criteria: preoperative B-mode ultrasound (US) including TIRADS classification (Kwak-TIRADS, EU-TIRADS), quantitative SWE and available histological results. Results: Out of 43 patients, 61 thyroid nodules were detected; 10 nodules were found to be thyroid cancer (7 PTC, 1 FTC, 2 HüCC) and 51 were benign. According to Kwak-TIRADS the majority of benign nodules (47 out of 51, 92.2%) were classified in the low-risk- and intermediate-risk class, four nodules were classified as high-risk (7.8%). When using EU-TIRADS, the benign nodules were distributed almost equally across all risk classes, 21 (41.2%) nodules were classified in the low-risk class, 16 (31.4%) in the intermediate-risk class and 14 (27.4%) in the high-risk class. In contrast, most of the malignant nodules (eight out of ten) were classified as high-risk on EU-TIRADS. One carcinoma was classified as low-risk and one as intermediate-risk nodule. For SWE, ROC analysis showed an optimal cutoff of 18.5 kPa to distinguish malignant and benign nodules (sensitivity 80.0%, specificity 49.0%, PPV 23.5% and NPV 92.6%). The addition of elastography resulted in an increase of accuracy from 65.6% to 82.0% when using Kwak-TIRADS and from 49.2% to 72.1% when using EU-TIRADS. Conclusion: Our data demonstrate that the combination of TIRADS and SWE seems to be superior for the risk stratification of thyroid nodules than each method by itself. However, verification of these results in a larger patient population is mandatory.
Collapse
Affiliation(s)
- Manuela Petersen
- Department of General, Visceral, Vascular and Transplant Surgery, University Hospital Magdeburg, 39120 Magdeburg, Germany;
- Correspondence: ; Tel./Fax: +49-(0)391-67-15500
| | - Simone A. Schenke
- Division of Nuclear Medicine, Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, 39120 Magdeburg, Germany; (S.A.S.); (J.F.); (M.C.K.)
- Department and Institute of Nuclear Medicine, Hospital Bayreuth, 95445 Bayreuth, Germany
| | - Jonas Firla
- Division of Nuclear Medicine, Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, 39120 Magdeburg, Germany; (S.A.S.); (J.F.); (M.C.K.)
| | - Roland S. Croner
- Department of General, Visceral, Vascular and Transplant Surgery, University Hospital Magdeburg, 39120 Magdeburg, Germany;
- Research Campus STIMULATE, Otto-von-Guericke University, 39106 Magdeburg, Germany
| | - Michael C. Kreissl
- Division of Nuclear Medicine, Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, 39120 Magdeburg, Germany; (S.A.S.); (J.F.); (M.C.K.)
- Research Campus STIMULATE, Otto-von-Guericke University, 39106 Magdeburg, Germany
| |
Collapse
|
9
|
Zhu YC, Zhang Y, Shan J, Deng SH, Shi XR, Jiang Q. Added Value of Superb Microvascular Imaging and Virtual Touch Imaging Quantification in Assisting Thyroid Cancer Classification. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:3364-3371. [PMID: 34489133 DOI: 10.1016/j.ultrasmedbio.2021.07.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 07/17/2021] [Accepted: 07/23/2021] [Indexed: 06/13/2023]
Abstract
This prospective study determined the value added by superb microvascular imaging (SMI) and Virtual Touch imaging quantification (VTIQ) to conventional ultrasonography in classifying malignant and benign thyroid nodules. One hundred eighty-three thyroid nodules (TNs) in 120 patients (112 benign and 71 malignant TNs) were evaluated. SMI revealed noticeable variance between benign and malignant TNs (p < 0.001). Malignant nodules tended to have rich vascularity (grade 3: 38/71, 53.5%) compared with benign nodules (grade 3: 33/112, 29.5%). There is a statistically significant difference between malignant and benign TNs with respect to shear-wave speed (SWS) values (all p values <0.001). The SWS mean, maximum and ratio of malignant nodules were 3.97 ± 1.34, 4.79 ± 1.70 and 1.25 ± 0.39, respectively. The SWS mean, maximum and ratio of benign nodules were 2.65 ± 0.42, 2.97 ± 0.46 and 1.15 ± 0.35, respectively. With respect to area under the curve values, the combined use of SMI or VTIQ improved the diagnostic performance of classifying malignant and benign TNs compared with that of ultrasonography alone. The combination of three modalities achieved the greatest area under the curve values (0.9811, 95% confidence interval: 0.95529-1.000), followed by US + VTIQ (0.9747, 0.94543-1.000), US + SMI (0.9032, 0.85345-0.95391) and ultrasonography (0.8291, 0.76417-0.89403).
Collapse
Affiliation(s)
- Yi-Cheng Zhu
- Department of Ultrasonography, Pudong New Area People's Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
| | - Yuan Zhang
- Department of Ultrasonography, Pudong New Area People's Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
| | - Jun Shan
- Department of Ultrasonography, Pudong New Area People's Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
| | - Shu-Hao Deng
- Department of Ultrasonography, Pudong New Area People's Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
| | - Xiu-Rong Shi
- Department of Ultrasonography, Pudong New Area People's Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China.
| | - Quan Jiang
- Department of Ultrasonography, Pudong New Area People's Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
| |
Collapse
|
10
|
Studeny T, Kratzer W, Schmidberger J, Graeter T, Barth TFE, Hillenbrand A. Analysis of vascularization in thyroid gland nodes with superb microvascular imaging (SMI) and CD34 expression histology: a pilot study. BMC Med Imaging 2021; 21:159. [PMID: 34717558 PMCID: PMC8557585 DOI: 10.1186/s12880-021-00690-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 10/19/2021] [Indexed: 11/28/2022] Open
Abstract
Background The Doppler sonography technique known as "superb microvascular imaging" (SMI) is advancing sonographic micro vascularization imaging in various disciplines. In this study, we aimed to determine whether SMI could reliably reproduce the blood flow in thyroid nodes and whether malignancy could be diagnosed, based on vascularization properties. Immunhistochemical staining by CD34 and SMI where used to determine the vascularization of nodes in terms of quantified vascularization parameters gained by computational evaluation. Methods We used image analysis programs to investigate whether the quantitative value for vascularization strength in the thyroid node, measured with SMI, was correlated with the actual degree of vascularization, determined microscopically. We included 16 patients that underwent thyroid resections. We prepared thyroid gland tissue slices for immunohistochemistry and labelled endothelial cells with CD34 to visualize blood vessels microscopically. We used image analysis programs, ImageJ, to quantify SMI Doppler sonographic measurements and CellProfiler to quantify CD34 expression in histological sections. We evaluated the numeric values for diagnostic value in node differentiation. Furthermore, we compared these values to check for correlations. Results Among the 16 nodes studied, three harboured malignant tumours (18.75%): two papillary and one follicular carcinoma. Among the 13 benign lesions (81.25%), four harboured follicular adenomas. Malignant and benign nodes were not significantly different in sonographic (0.88 ± 0.89 vs. 1.13 ± 0.19; p = 0.2790) or immunohistochemical measurements of vascularization strength (0.05 ± 0.05 vs. 0.08 ± 0.06; p = 0.2260). Conclusion We found a positive, significant correlation (r = 0.55588; p = 0.0254) between SMI (quantitative values for vascularization strength) and immunohistochemistry (CD34 staining) evaluations of thyroid nodes.
Collapse
Affiliation(s)
- Thomas Studeny
- Department of Internal Medicine I, Ulm University Hospital, Albert-Einstein-Allee 23, 89081, Ulm, Germany
| | - Wolfgang Kratzer
- Department of Internal Medicine I, Ulm University Hospital, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
| | - Julian Schmidberger
- Department of Internal Medicine I, Ulm University Hospital, Albert-Einstein-Allee 23, 89081, Ulm, Germany
| | - Tilmann Graeter
- Department of Diagnostic and Interventional Radiology, Ulm University Hospital, Albert-Einstein-Alee 23, 89081, Ulm, Germany
| | - Thomas F E Barth
- Institute of Pathology, Ulm University Hospital, Albert-Einstein-Allee 23, 89081, Ulm, Germany
| | - Andreas Hillenbrand
- Department of General and Visceral Surgery, Ulm University Hospital, Albert-Einstein-Alee 23, 89081, Ulm, Germany
| |
Collapse
|
11
|
Zhang WB, Xu W, Fu WJ, He BL, Liu H, Deng WF. Comparison of ACR TI-RADS, Kwak TI-RADS, ATA guidelines and KTA/KSThR guidelines in combination with SWE in the diagnosis of thyroid nodules. Clin Hemorheol Microcirc 2021; 78:163-174. [PMID: 33579829 DOI: 10.3233/ch-201021] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
OBJECTIVE To compare the diagnostic efficacy of ACR TI-RADS, Kwak TI-RADS, ATA guidelines and KTA/KSThR guidelines in combination with shear wave elastography (SWE) for thyroid nodules. METHODS The retrospective study included 566 thyroid nodules with maximum diameter≥5 mm which confirmed by FNA cytology or/and surgical pathology. The sensitivity, specificity, accuracy, Youden index of diagnosis of thyroid nodules by ACR TI-RADS, Kwak TI-RADS, ATA guidelines, KTA/KSThR guidelines and SWE were calculated. The ROC curve was drawn to determine the cut-off values of the four ultrasound classification systems and SWE Emax. The diagnostic efficacy of the four ultrasound classification systems in combination with SWE were calculated and compared with those of pre-combination. RESULTS The ROC curves indicated that the cut-off value of ACR TI-RADS, Kwak TI-RADS, ATA guidelines, KTA/KSThR guidelines and Emax of SWE was TR5, 4c, high-suspicion, high-suspicion, and 41.7 kPa, respectively, and the area under the ROC curve (AUC) was 0.907(0.879-0.934), 0904(0.876-0.932), 0.894(0.863-0.924), 0.888(0.856-0.919), 0.886(0.859-0.913), respectively. After combination with SWE, the the sensitivities of the four ultrasound classification systems for the diagnosis of nodules were improved, and the differences were statistically significant (all P≤0.001); the specificities were decreased, but the differences were not statistically significant (all P > 0.05); the accuracies were improved, but only the difference of ACR TI-RADS was statistically significant (x2 = 4.45, P = 0.035); the differences in the AUCs were not significant (all P > 0.05). CONCLUSIONS The four ultrasound classification systems and SWE all had high performance in the diagnosis of thyroid nodules. The four classification systems in combination with SWE were all beneficial to the differential diagnosis of nodules, and ACR TI-RADS in combination with SWE was more effective, especially for TR3 and TR4 nodules.
Collapse
Affiliation(s)
- Wei-Bing Zhang
- Department of Medical Ultrasound, Jiangsu Provincial Corps Hospital, Chinese People's Armed Police Forces, Yangzhou, China
| | - Wen Xu
- Department of Medical Imaging, Beijing Provincial Corps Hospital, Chinese People's Armed Police Forces, Beijing, China
| | - Wen-Jie Fu
- Department of Surgery, Jiangsu Provincial Corps Hospital, Chinese People's Armed Police Forces, Yangzhou, China
| | - Bei-Li He
- Department of Medical Ultrasound, Jiangsu Provincial Corps Hospital, Chinese People's Armed Police Forces, Yangzhou, China
| | - Hua Liu
- Department of Medical Ultrasound, Jiangsu Provincial Corps Hospital, Chinese People's Armed Police Forces, Yangzhou, China
| | - Wen-Fang Deng
- Department of Orthopedics, Subei People's Hospital of Jiangsu Province, Yangzhou, China
| |
Collapse
|
12
|
Wang Y, Dong T, Nie F, Wang G, Liu T, Niu Q. Contrast-Enhanced Ultrasound in the Differential Diagnosis and Risk Stratification of ACR TI-RADS Category 4 and 5 Thyroid Nodules With Non-Hypovascular. Front Oncol 2021; 11:662273. [PMID: 34123819 PMCID: PMC8189148 DOI: 10.3389/fonc.2021.662273] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Accepted: 04/26/2021] [Indexed: 12/24/2022] Open
Abstract
Objective This study aims to investigate the value of contrast-enhanced ultrasound (CEUS) in the differential diagnosis and risk stratification of ACR TI-RADS category 4 and 5 thyroid nodules with non-hypovascular. Methods From January 2016 to December 2019 in our hospital, 217 ACR TI-RADS category 4 and 5 nodules with non-hypovascular in 210 consecutive patients were included for a derivation cohort. With surgery and/or fine-needle aspiration (FNA) as a reference, conventional ultrasound (US) features and CEUS features were analyzed. Multivariate logistic regression analysis was used to screen the independent risk factors and establish a risk predictive model. Between January 2020 and March 2021, a second cohort of 100 consecutive patients with 101 nodules were included for an external validation cohort. The model was converted into a simplified risk score and was validated in the validation cohort. The area under the receiver operating characteristic curves (AUC) were used to assess the models’ diagnostic performance. Results Micro-calcification, irregular margin, earlier wash-out, centripetal enhancement, and absence of ring enhancement were independent risk factors and strongly discriminated malignancy in the derivation cohort (AUC = 0.921, 95% CI 0.876–0.953) and the validation cohort (0.900, 0.824–0.951). There was no significant difference (P = 0.3282) between the conventional US and CEUS in differentiating malignant non-hypovascular thyroid nodules, but a combination of them (the predictive model) had better performance than the single method (all P <0.05), with a sensitivity of 87.0%, specificity of 86.2%, and accuracy of 86.6% in the derivation cohort. The risk score based on the independent risk factors divided non-hypovascular thyroid nodules into low-suspicious (0–3 points; malignancy risk <50%) and high-suspicious (4–7 points; malignancy risk ≥ 50%), the latter with nodule ≥10mm was recommended for FNA. The risk score showed a good ability of risk stratification in the validation cohort. Comparing ACR TI-RADS in screening suitable non-hypovascular nodules for FNA, the risk score could avoid 30.8% benign nodules for FNA. Conclusions CEUS is helpful in combination with conventional US in differentiating ACR TI-RADS category 4 and 5 nodules with non-hypovascular. The risk score in this study has the potential to improve the diagnosis and risk stratification of non-hypovascular thyroid nodules.
Collapse
Affiliation(s)
- Yanfang Wang
- Medical Center of Ultrasound, Lanzhou University Second Hospital, Lanzhou, China
| | - Tiantian Dong
- Medical Center of Ultrasound, Lanzhou University Second Hospital, Lanzhou, China
| | - Fang Nie
- Medical Center of Ultrasound, Lanzhou University Second Hospital, Lanzhou, China
| | - Guojuan Wang
- Medical Center of Ultrasound, Lanzhou University Second Hospital, Lanzhou, China
| | - Ting Liu
- Medical Center of Ultrasound, Lanzhou University Second Hospital, Lanzhou, China
| | - Qian Niu
- Department of Pathology, Lanzhou University Second Hospital, Lanzhou, China
| |
Collapse
|
13
|
Fu Z, Zhang J, Lu Y, Wang S, Mo X, He Y, Wang C, Chen H. Clinical Applications of Superb Microvascular Imaging in the Superficial Tissues and Organs: A Systematic Review. Acad Radiol 2021; 28:694-703. [PMID: 32418782 DOI: 10.1016/j.acra.2020.03.032] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 03/13/2020] [Accepted: 03/20/2020] [Indexed: 12/12/2022]
Abstract
Superb microvascular imaging (SMI) is an innovative Doppler technique for vascular examination. It uses an intelligent algorithm that efficiently separates low-speed flow signals from motion artifacts so that it can assess microvessels and the vessel distribution in detail. This article reviews the clinical applications of SMI in the disorders of superficial tissues and organs including thyroid nodules, breast tumors and lymph node diseases etc. More information of diseases that are closely associated with angiogenesis can be shown by SMI than other noninvasive examinations. Although some limitations exist, this safe and convenient technique is becoming acceptable and would play a more important role in disease diagnosis and therapeutic responses evaluation.
Collapse
|
14
|
Zhang J, Deng Y, Tang Q, Sun J, Huang L, Song P, Bi X. Evaluation of Myocardial Stiffness in Hypertensive Patients by Intrinsic Wave Propagation of the Myocardial Stretch. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2683-2691. [PMID: 32709521 DOI: 10.1016/j.ultrasmedbio.2020.06.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 06/19/2020] [Accepted: 06/23/2020] [Indexed: 06/11/2023]
Abstract
The objective of the study was to evaluate myocardial stiffness in hypertensive patients by measuring the intrinsic velocity propagation (IVP) of the myocardial stretch and to explore the correlation between IVP and cardiac systolic and diastolic functions. Eighty-one hypertensive patients and 53 healthy patients were prospectively enrolled in this study. IVP was measured using high-frame rate tissue Doppler (350-450 frames per second). IVP was significantly higher in hypertensive patients than in the control group (1.53 ± 0.39 m/s vs. 1.40 ± 0.19 m/s, p = 0.031). In the hypertensive group, IVP was significantly higher in patients with electrocardiogram (ECG) strain than in those without ECG strain (1.63 ± 0.46 m/s vs. 1.45 ± 0.32 m/s, p = 0.047). Moreover, IVP exhibited a good correlation with interventricular septal thickness at end-diastole (r = 0.434, p < 0.001), left ventricular posterior wall thickness at end-diastole (r = 0.439, p < 0.001), E/A ratio (r = 0.245, p = 0.004) and global longitudinal systolic strain (r = 0.405, p < 0.001). IVP was significantly higher in hypertensive patients, which indicates elevated myocardial stiffness in this cohort of patients. This novel measurement exhibited great potential for use in clinical practice to assess myocardial stiffness in patients with hypertension non-invasively.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Youbin Deng
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Qiaoying Tang
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Jie Sun
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Lingying Huang
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Pengfei Song
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA; Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Xiaojun Bi
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
| |
Collapse
|
15
|
Wang J, Wei W, Guo R. Ultrasonic elastography and conventional ultrasound in the diagnosis of thyroid micro-nodules. Pak J Med Sci 2019; 35:1526-1531. [PMID: 31777487 PMCID: PMC6861480 DOI: 10.12669/pjms.35.6.777] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Objective: To investigate the clinical value of conventional ultrasound, ultrasound elastography and conventional ultrasound combined with ultrasound elastography in differential diagnosis of benign and malignant thyroid micro-nodules. Methods: Eighty-six patients who were found with thyroid micro-nodules with the maximum diameter no more than 10 mm in the physical examination in our hospital from June 2015 to December 2017 were selected, and 102 nodules were included. All patients were confirmed with thyroid micro-nodules by puncture or surgical pathology and underwent conventional ultrasound and ultrasound elastography. Taking the surgical pathological results as a control, the value of conventional ultrasound, ultrasound elastography and conventional ultrasound combined with ultrasound elastography in differential diagnosis of benign and malignant thyroid micro-nodules were compared. A receiver operating characteristic (ROC) curve was drawn, and the area under the ROC curve was calculated. Results: One hundred and two thyroid nodules were detected by surgical pathology, including 75 benign nodules (73.53%) and 27 malignant nodules (26.47%). The sensitivity and diagnostic accordance rate of ultrasound elastography were significantly higher than those of conventional ultrasound in the diagnosis of thyroid microcarcinoma, and the missed diagnosis rate of ultrasound elastography was significantly lower than that of conventional ultrasound; the difference was statistically significant (P<0.05). However, the difference between the two methods was not statistically significant in terms of diagnostic specificity and misdiagnosis rate (P>0.05). The areas under the ROC curve in the diagnosis of benign and malignant thyroid nodules by conventional ultrasound and ultrasound elastography were 0.735 and 0.743 respectively. Conclusion: Conventional ultrasound can be used as a routine examination technique in differential diagnosis of benign and malignant thyroid nodules, while ultrasound elastography can improve the sensitivity and diagnostic rate in the diagnosis of thyroid micro carcinoma. It can help to reduce the clinical missed diagnosis, which also can be be used as an effective supplement for conventional ultrasound.
Collapse
Affiliation(s)
- Jinming Wang
- Jinming Wang Department of Ultrasound, Binzhou People's Hospital, Shandong, 256610, China
| | - Wenbing Wei
- Wenbing Wei Department of Ultrasound, Binzhou People's Hospital, Shandong, 256610, China
| | - Rui Guo
- Rui Guo Department of Ultrasound, Binzhou People's Hospital, Shandong, 256610, China
| |
Collapse
|
16
|
Jiang ZZ, Huang YH, Shen HL, Liu XT. Clinical Applications of Superb Microvascular Imaging in the Liver, Breast, Thyroid, Skeletal Muscle, and Carotid Plaques. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:2811-2820. [PMID: 30953387 DOI: 10.1002/jum.15008] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Revised: 02/21/2019] [Accepted: 02/25/2019] [Indexed: 06/09/2023]
Abstract
This article reviews the clinical applications of Superb Microvascular Imaging (SMI; Canon Medical Systems, Otawara, Japan) in the liver, breast, thyroid, skeletal muscle, and carotid plaques. Diseases that are closely associated with angiogenesis can be diagnosed by SMI in a relatively early phase, and using SMI can prevent adverse reactions associated with the contrast agents used in contrast-enhanced ultrasound. Super Microvascular Imaging also shows particular value in grading disease activities and monitoring therapeutic responses. Although SMI has some limitations, such as a lack of clinical standards, it can add information to conventional ultrasound examinations and may become a noninvasive alternative to invasive diagnostic procedures for many clinical conditions.
Collapse
Affiliation(s)
- Zhen-Zhen Jiang
- Department of Ultrasound, Shaoxing People's Hospital, Shaoxing Hospital, Zhejiang University School of Medicine, Shaoxing, China
| | - Yan-Hua Huang
- Department of Ultrasound, Shaoxing People's Hospital, Shaoxing Hospital, Zhejiang University School of Medicine, Shaoxing, China
| | - Hua-Liang Shen
- Department of Ultrasound, Shaoxing People's Hospital, Shaoxing Hospital, Zhejiang University School of Medicine, Shaoxing, China
| | - Xia-Tian Liu
- Department of Ultrasound, Shaoxing People's Hospital, Shaoxing Hospital, Zhejiang University School of Medicine, Shaoxing, China
| |
Collapse
|
17
|
Li X, Hou XJ, Du LY, Wu JQ, Wang L, Wang H, Zhou XL. Virtual Touch Tissue Imaging and Quantification (VTIQ) combined with the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) for malignancy risk stratification of thyroid nodules. Clin Hemorheol Microcirc 2019; 72:279-291. [PMID: 30856102 DOI: 10.3233/ch-180477] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Xiang Li
- In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Nangang, Harbin, Heilongjiang, China
| | - Xiu-Juan Hou
- In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Nangang, Harbin, Heilongjiang, China
| | - Lin-Yao Du
- In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Nangang, Harbin, Heilongjiang, China
| | - Jia-Qi Wu
- In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Nangang, Harbin, Heilongjiang, China
| | - Luo Wang
- In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Nangang, Harbin, Heilongjiang, China
| | - Hong Wang
- In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Nangang, Harbin, Heilongjiang, China
| | - Xian-Li Zhou
- In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Nangang, Harbin, Heilongjiang, China
| |
Collapse
|