1
|
Nylund K, Novak K, Wilkens R. Comment on "Ultrasonographic scores for ileal Crohn's disease assessment: better, worse or the same as contrast‑enhanced ultrasound?". BMC Gastroenterol 2023; 23:265. [PMID: 37542237 PMCID: PMC10403931 DOI: 10.1186/s12876-023-02882-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Accepted: 07/11/2023] [Indexed: 08/06/2023] Open
Abstract
We read with interest the study by Freitas et al. comparing contrast-enhanced ultrasound (CEUS) and parameters from a time-intensity curve (TIC) with the SUS-CD score and IBUS-SAS score in patients with Crohn's disease (CD) undergoing gastrointestinal ultrasound (GIUS) and ileocolonoscopy. The aim was to compare the accuracy of CEUS and aforementioned scores in predicting terminal ileal inflammatory activity in patients with CD. In this retrospective study of 50 patients, inflammatory activity was defined as a segmental score of SES-CD ≥ 7 in the terminal ileum. The study found 30 patients with active endoscopic disease demonstrating no significant difference between the "inactive" and "active" SUS CD and IBUS-SAS scores. However, the CEUS peak enhancement derived from the TIC was shown to be significantly different. The authors conclude CEUS was superior for detecting inflammation in the terminal ileum, as opposed to ultrasound scores relying on bowel wall thickness and color Doppler.
Collapse
Affiliation(s)
- Kim Nylund
- National Center of Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway.
| | - Kerri Novak
- Division of Gastroenterology and Hepatology, Department of Medicine, University of Calgary, Calgary, AB, Canada
| | - Rune Wilkens
- Digestive Disease Center, Division of Medicine, Copenhagen University Hospital - Bispebjerg & Frederiksberg, Copenhagen, Denmark
| |
Collapse
|
2
|
Paratore M, Garcovich M, Ainora ME, Riccardi L, Gasbarrini A, Zocco MA. Dynamic contrast enhanced ultrasound in gastrointestinal diseases: A current trend or an indispensable tool? World J Gastroenterol 2023; 29:4021-4035. [PMID: 37476588 PMCID: PMC10354578 DOI: 10.3748/wjg.v29.i25.4021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 05/24/2023] [Accepted: 06/05/2023] [Indexed: 06/28/2023] Open
Abstract
Contrast enhanced ultrasound (CEUS) has been widely implemented in clinical practice because of the enormous quantity of information it provides, along with its low cost, reproducibility, minimal invasiveness, and safety of the second-generation ultrasound contrast agents. To overcome the limitation of CEUS given by the subjective evaluation of the contrast enhancement behaviour, quantitative analysis of contrast kinetics with generation of time-intensity curves has been introduced in recent years. The quantification of perfusion parameters [named as dynamic-CEUS (D-CEUS)] has several applications in gastrointestinal neoplastic and inflammatory disorders. However, the limited availability of large studies and the heterogeneity of the technologies employed have precluded the standardisation of D-CEUS, which potentially represents a valuable tool for clinical practice in management of gastrointestinal diseases. In this article, we reviewed the evidence exploring the application of D-CEUS in gastrointestinal diseases, with a special focus on liver, pancreas, and inflammatory bowel diseases.
Collapse
Affiliation(s)
- Mattia Paratore
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Matteo Garcovich
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Maria Elena Ainora
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Laura Riccardi
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Antonio Gasbarrini
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Maria Assunta Zocco
- Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Università Cattolica del Sacro Cuore, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| |
Collapse
|
3
|
Goncin U, Curiel L, Geyer CR, Machtaler S. Aptamer-Functionalized Microbubbles Targeted to P-selectin for Ultrasound Molecular Imaging of Murine Bowel Inflammation. Mol Imaging Biol 2023; 25:283-293. [PMID: 35851673 DOI: 10.1007/s11307-022-01755-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 06/01/2022] [Accepted: 07/06/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE Our objectives were to develop a targeted microbubble with an anti-P-selectin aptamer and assess its ability to detect bowel inflammation in two murine models of acute colitis. PROCEDURES Lipid-shelled microbubbles were prepared using mechanical agitation. A rapid copper-free click chemistry approach (azide-DBCO) was used to conjugate the fluorescent anti-P-selectin aptamer (Fluor-P-Ap) to the microbubble surface. Bowel inflammation was chemically induced using 2,4,6-trinitrobenzenesulfonic acid (TNBS) in both Balb/C and interleukin-10-deficient (IL-10 KO) mice. Mouse bowels were imaged using non-linear contrast mode following an i.v. bolus of 1 × 108 microbubbles. Each mouse received a bolus of aptamer-functionalized and non-targeted microbubbles. Mouse phenotypes and the presence of P-selectin were validated using histology and immunostaining, respectively. RESULTS Microbubble labelling of Fluor-P-Ap was complete after 20 min at 37 ̊C. We estimate approximately 300,000 Fluor-P-Ap per microbubble and confirmed fluorescence using confocal microscopy. There was a significant increase in ultrasound molecular imaging signal from both Balb/C (p = 0.003) and IL-10 KO (p = 0.02) mice with inflamed bowels using aptamer-functionalized microbubbles in comparison to non-targeted microbubbles. There was no signal in healthy mice (p = 0.4051) using either microbubble. CONCLUSIONS We constructed an aptamer-functionalized microbubble specific for P-selectin using a clinically relevant azide-DBCO click reaction, which could detect bowel inflammation in vivo. Aptamers have potential as a next generation targeting agent for developing cost-efficient and clinically translatable targeted microbubbles.
Collapse
Affiliation(s)
- Una Goncin
- Department of Medical Imaging, University of Saskatchewan, Saskatoon, SK, S7N 5E5, Canada
| | - Laura Curiel
- Department of Electrical and Software Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB, T2N 4V8, Canada
| | - C Ronald Geyer
- Department of Pathology and Laboratory Medicine, University of Saskatchewan, Saskatoon, SK, S7N 5E5, Canada
| | - Steven Machtaler
- Department of Medical Imaging, University of Saskatchewan, Saskatoon, SK, S7N 5E5, Canada.
| |
Collapse
|
4
|
Gokli A, Dillman JR, Humphries PD, Ključevšek D, Mentzel HJ, Rubesova E, Takahashi MS, Anupindi SA. Contrast-enhanced ultrasound of the pediatric bowel. Pediatr Radiol 2021; 51:2214-2228. [PMID: 33978797 PMCID: PMC8113288 DOI: 10.1007/s00247-020-04868-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 08/13/2020] [Accepted: 09/30/2020] [Indexed: 01/03/2023]
Abstract
Contrast-enhanced ultrasound (CEUS) has emerged as a valuable modality for bowel imaging in adults and children. CEUS enables visualization of the perfusion of the bowel wall and of the associated mesentery in healthy and disease states. In addition, CEUS images can be used to make quantitative measurements of contrast kinetics, allowing for objective assessment of bowel wall enhancement. Bowel CEUS is commonly applied to evaluate inflammatory bowel disease and to monitor treatment response. It has also been applied to evaluate necrotizing enterocolitis, intussusception, appendicitis and epiploic appendagitis, although experience with these applications is more limited. In this review article, we present the current experience using CEUS to evaluate the pediatric bowel with emphasis on inflammatory bowel disease, extrapolating the established experience from adult studies. We also discuss emerging applications of CEUS as an adjunct or problem-solving tool for evaluating bowel perfusion.
Collapse
Affiliation(s)
- Ami Gokli
- Department of Radiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.
| | - Jonathan R. Dillman
- grid.239573.90000 0000 9025 8099Department of Radiology, Cincinnati Children’s Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, OH USA
| | - Paul D. Humphries
- grid.420468.cUniversity College London Hospital NHS Trust, Great Ormond Street Hospital for Children, London, UK
| | - Damjana Ključevšek
- grid.29524.380000 0004 0571 7705Department of Radiology, University Children’s Hospital Ljubljana, Ljubljana, Slovenia
| | - Hans-Joachim Mentzel
- grid.275559.90000 0000 8517 6224Section of Pediatric Radiology, Institute of Diagnostic and Interventional Radiology, University Hospital Jena, Jena, Germany
| | - Erika Rubesova
- grid.240952.80000000087342732Department of Radiology, Lucile Packard Children’s Hospital, Stanford University Medical Center, Stanford, CA USA
| | - Marcelo S. Takahashi
- Pediatric Radiology Department, Diagnósticos da America (DASA), São Paulo, Brazil
| | - Sudha A. Anupindi
- grid.25879.310000 0004 1936 8972Department of Radiology, Children’s Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, 3401 Civic Center Blvd., Philadelphia, PA 19104 USA
| |
Collapse
|
5
|
Yang X, Lovell JF, Zhang Y. Ingestible Contrast Agents for Gastrointestinal Imaging. Chembiochem 2019; 20:462-473. [PMID: 30421487 DOI: 10.1002/cbic.201800589] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Indexed: 12/17/2022]
Abstract
Gastrointestinal (GI) ailments cover a wide variety of diseases involving the esophagus, stomach, small intestine, large intestine, and rectum. They bring about many inconveniences in daily life in chronic diseases and can even be life threatening in acute cases. Rapid and safe detection approaches are essential for early diagnosis and timely management. Contrast agents for GI imaging can enhance contrast to distinguish abnormal lesions from normal structures. Computed tomography and magnetic resonance imaging are two important diagnostic tools for the evaluation of GI conditions. This review mainly involves several common GI diseases, including inflammatory diseases, intestinal tumors, diarrhea, constipation, and gastroesophageal reflux diseases. Selected contrast agents, such as barium sulfate, iodine-based agents, gadolinium-based agents, and others, are summarized. Going forward, continued endeavors are being made to develop more emerging contrast agents for other imaging modalities.
Collapse
Affiliation(s)
- Xingyue Yang
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 301636, China
| | - Jonathan F Lovell
- Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, 14260, USA
| | - Yumiao Zhang
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 301636, China
| |
Collapse
|