1
|
Kim JK, Kang B, Kim YS, Cha Y, Jang MJ, Bae D, You D. Evaluation of the suitability of using ArtiSential in various renal surgery: IDEAL stage 1 study. BMC Urol 2024; 24:164. [PMID: 39090576 PMCID: PMC11293067 DOI: 10.1186/s12894-024-01539-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 07/09/2024] [Indexed: 08/04/2024] Open
Abstract
BACKGROUND ArtiSential, a new articulating laparoscopic instruments, addresses the limited movement associated with conventional laparoscopic instruments. This study was conducted to assess the clinical effectiveness of ArtiSential in detailed steps of various renal surgery. METHODS This study was approved by the Institutional Review Board of our institution and registered on the Clinical Research Information Service site of the Korea Disease Control and Prevention Agency. Participants meeting all inclusion and exclusion criteria were included in the clinical trial and underwent renal surgery. The clinical effectiveness of ArtiSential was assessed in terms of the feasibility and objective and subjective parameters across 9 detailed steps. RESULTS Of the 15 potential candidates enrolled from October 2021 to November 2021, 1 patient dropped out due to anaphylaxis from an anesthetic agent, and 14 patients underwent laparoscopic surgery using ArtiSential. Of the 14 patients, 2 patients were converted to laparoscopic surgery using straight-shaped instruments due to the ischemia time exceeding 30 min, and 1 patient due to excessive bleeding. The feasibility for most steps was more than 90%, except the renorrhaphy step. The median total operation time and ischemia time were 161 and 23 min, respectively. The median estimated blood loss was 58.5 mL. Two cases of venous injury occurred during renal pedicle dissection step. The accuracy of the procedure judged by reviewers and usability judged by the operator were acceptable in all steps. The surgeon's quantitatively measured stress score was the highest during renorrhaphy step. CONCLUSIONS Laparoscopic surgery using ArtiSential is feasible for most steps except the renorrhaphy step. The difficulty of performing renorrhaphy is attributed to prolonged ischemia time, which could be addressed by overcoming the learning curve. TRIAL REGISTRATION Clinical Research Information Service site of the Korea Disease Control and Prevention Agency, KCT0006532. Registered 03/09/2021, https://cris.nih.go.kr/cris/search/detailSearch.do?seq=24071 .
Collapse
Affiliation(s)
- Jong Keun Kim
- Department of Urology, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Republic of Korea
| | - Bosik Kang
- Department of Urology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Yu Seon Kim
- Department of Urology, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Yunhwa Cha
- Department of Urology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Myoung Jin Jang
- Asan Institute for Life Sciences, Asan Medical Center, Seoul, Republic of Korea
| | | | - Dalsan You
- Department of Urology, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
| |
Collapse
|
2
|
Kim JK, Kang B, Kim YS, Yun Y, Jang MJ, Bae D, You D. Laparoscopic renal surgery using multi degree-of-freedom articulating laparoscopic instruments in a porcine model. Investig Clin Urol 2023; 64:91-101. [PMID: 36629070 PMCID: PMC9834568 DOI: 10.4111/icu.20220182] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 08/22/2022] [Accepted: 11/22/2022] [Indexed: 12/28/2022] Open
Abstract
PURPOSE We evaluated the performance of a new multi-degree-of-freedom articulating laparoscopic instrument, ArtiSential, and compared it with that of a straight-shaped instrument and the da Vinci surgical system, in renal surgery using porcine model. MATERIALS AND METHODS Nine female Yorkshire pigs were equally divided into three groups. The three groups were compared at each surgical step in terms of objective and subjective parameters. RESULTS The median operative times for renal pedicle clamping and ureter dissection were significantly shorter in ArtiSential group than robotic group (1.3 min vs. 4.7 min, p=0.002; 8.1 min vs. 11.1 min, p=0.015). The median operative time for bladder repair was significantly longer in ArtiSential group than robotic and straight-shaped groups (17.9 min vs. 5.5 min, p=0.002; 17.9 min vs. 9.3 min, p=0.026). There were no significant differences among groups in terms of blood loss or intraoperative complications. ArtiSential device was less useable for renorrhaphy (p=0.009) and bladder repair (p=0.002) compared to the robotic system. ArtiSential group was less accurate than robotic group in terms of tumor resection, renorrhaphy, and bladder repair. During ureter dissection, bladder cuff excision, and bladder repair, the surgeon experienced greater wrist discomfort but lesser back discomfort in ArtiSential group than robotic group. CONCLUSIONS For most steps, ArtiSential performed as well as robotic and straight-shaped instruments. The development of specialized surgical techniques for ArtiSential will maximize the advantages of these instruments.
Collapse
Affiliation(s)
- Jong Keun Kim
- Department of Urology, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea
| | - Bosik Kang
- Department of Urology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Yu Seon Kim
- Department of Urology, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Yujin Yun
- Robotic Surgery Center, Asan Medical Center, Seoul, Korea
| | - Myoung Jin Jang
- Asan Institute for Life Sciences, Asan Medical Center, Seoul, Korea
| | | | - Dalsan You
- Department of Urology, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
3
|
van der Vliet WJ, Spaans LN, Bonouvrie DS, Uittenbogaart M, Leclercq WKG. Safety and Efficiency of an Articulating Needle Driver in Advanced Laparoscopic Abdominal Surgery. J Laparoendosc Adv Surg Tech A 2021; 32:422-426. [PMID: 34936817 DOI: 10.1089/lap.2021.0272] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Objective: Robotic platforms offer articulating needle drivers but are associated with high costs and lack tactile feedback. The recently developed mechanical Laparoscopic Articulating Needle Driver (LAND) (Flexdex®) for conventional laparoscopy offers enhanced dexterity without these limitations. The goal of this study was to assess safety and efficiency during the implementation of the LAND, and describe its learning curve, in an expert center for laparoscopic surgery. Methods: All LAND-assisted procedures after clinical implementation for a period of 16 months were included into this study. Primary outcome domains were safety (intra- and postoperative complications within 30 days) and efficiency (operative time, suturing, and knot tying time of staple defects of enteroenterostomy). CUmulative SUM (CUSUM) analysis was utilized to describe the enteroenterostomy suturing time learning curve across consecutive cases by plotting the deviation from the series mean. Results: Forty-five procedures (34 Roux-en-Y gastric bypass [of which 7 including diaphragmatic hernia repair], 2 diaphragmatic hernia repair with Nissen fundoplication, and 2 right-sided hemicolectomy) were included into this study. Median (range) operative time and enteroenterostomy suturing time were 68 (46-177) minutes and 161 (112-241) seconds, respectively, comparable with conventional needle driver standards. One procedure was converted to the conventional needle driver due to device malfunctioning and one patients' postoperative course was complicated by a Clavien-Dindo grade 3a complication (intraluminal bleeding requiring gastroscopy). CUSUM chart displays a progression toward the mean from case 22 onward, indicating a limited learning curve. Conclusion: The LAND can be implemented safely and efficiently at a center of excellence for laparoscopic surgery and is associated with a limited learning curve.
Collapse
Affiliation(s)
- Walderik J van der Vliet
- Department of Surgery, Máxima Medical Center, Veldhoven, The Netherlands.,NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands
| | - Louisa N Spaans
- Department of Surgery, Máxima Medical Center, Veldhoven, The Netherlands
| | | | - Martine Uittenbogaart
- Department of Surgery, Máxima Medical Center, Veldhoven, The Netherlands.,NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands
| | | |
Collapse
|
4
|
Videourology Abstracts. J Endourol 2021. [DOI: 10.1089/end.2021.29118.vid] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
5
|
Francavilla S, Abern MR, Dobbs RW, Vigneswaran HT, Talamini S, Antonelli A, Simeone C, Crivellaro S. Single-Port robot assisted partial nephrectomy: initial experience and technique with the da Vinci Single-Port platform (IDEAL Phase 1). Minerva Urol Nephrol 2021; 74:216-224. [PMID: 33769009 DOI: 10.23736/s2724-6051.21.03919-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND To evaluate the safety and feasibility of robotic-assisted laparoscopic partial nephrectomy (RAPN) performed using the da Vinci Single-Port (SP) platform. METHODS A retrospective review was conducted from December 2018 to December 2019 of 14 consecutive patients with localized renal cancer who underwent SP robot-assisted partial nephrectomy at a single institution. The procedures were performed by 2 experienced robotic surgeons, reproducing the steps of the standard multiport robotic approach to partial nephrectomy. A transperitoneal approach was utilized with a 2.5 cm para-rectus incision with one assistant 12 mm laparoscopic port. RESULTS No conversions to open or laparoscopic surgery occurred and no additional laparoscopic assistant ports were required. The median total operative time was 202 (162-231) minutes and the median total room time was 258 (215-295) minutes. The warm ischemia time averaged 20 minutes ± 8 minutes. 2 patients required angioembolization due to postoperative acute bleeding (Clavien-Dindo Grade 3a complication). Trifecta outcome (<25 min warm ischemia, no perioperative complications and negative margins) was achieved in 79% of patients. In one case, a positive margin was present. The median length of stay was of 1 day (Interquartile Range 1-2) with a median pain score on postoperative day 1 of 3.5 (Interquartile Range 2.4-5). 1/14 (7%) patient needed narcotic use at one week from discharge. At a median follow up of 5.0 (4.0-8.0) months, no patients have had evidence of disease recurrence. CONCLUSIONS In this initial cohort, considering the introduction of a new technology, we observed satisfactory outcomes for several key perioperative variables including operative time, warm ischemia time, surgical margins, hospital stay, pain requirements in patients undergoing RAPN with the SP platform. For experienced robotic surgeons, RAPN with the SP platform is a safe and feasible approach for single site partial nephrectomy.
Collapse
Affiliation(s)
- Simone Francavilla
- Department of Urology, College of Medicine, University of Illinois at Chicago, Chicago, IL, USA - .,Urology Unit, ASST Spedali Civili Hospital, Brescia, Italy - .,Department of Medical and Surgical Specialties, Radiological Science, and Public Health, University of Brescia, Brescia, Italy -
| | - Michael R Abern
- Department of Urology, College of Medicine, University of Illinois at Chicago, Chicago, IL, USA
| | - Ryan W Dobbs
- Department of Urology, College of Medicine, University of Illinois at Chicago, Chicago, IL, USA
| | - Hari T Vigneswaran
- Department of Urology, College of Medicine, University of Illinois at Chicago, Chicago, IL, USA
| | - Susan Talamini
- Department of Urology, College of Medicine, University of Illinois at Chicago, Chicago, IL, USA
| | - Alessandro Antonelli
- Urology Unit, Department of Surgery, Dentistry, Pediatrics and Gynecology, Azienda Ospedaliero Universitaria Integrata di Verona, University of Verona, Verona, Italy
| | | | - Simone Crivellaro
- Department of Urology, College of Medicine, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
6
|
Evaluation of new motorized articulating laparoscopic instruments by laparoscopic novices using a standardized laparoscopic skills curriculum. Surg Endosc 2020; 35:979-988. [PMID: 33079238 PMCID: PMC7819923 DOI: 10.1007/s00464-020-08086-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 10/03/2020] [Indexed: 11/29/2022]
Abstract
Background Motorized articulating laparoscopic instruments (ALI) offer more degrees of freedom than conventional laparoscopic instruments (CLI). However, a difficult learning curve and complex instrument handling are still a problem of ALI. We compared the performance of new prototypes of motorized ALI with CLI in a series of standardized laparoscopic tasks performed by laparoscopic novices. Further, usability of the new ALI was assessed. Methods A randomized cross-over study with 50 laparoscopic novices who either started with CLI and then changed to ALI (CA) or vice versa (AC) was conducted. All participants performed the European training in basic laparoscopic urological skills (E-BLUS) with each instrument in given order. Time and errors were measured for each exercise. Instrument usability was assessed. Results Overall, using CLI was significantly faster (CLI 4:27 min vs. ALI 4:50 min; p-value 0.005) and associated with fewer exercise failures in needle guidance (CLI 0 vs. ALI 12; p-value 0.0005) than ALI. Median amount of errors was similar for both instruments. Instrument sequence did not matter, as CA and AC showed comparable completion times. Regarding the learning effect, participants were significantly faster in the second attempt of exercises than in the first. In the needle guidance task, participants using CLI last demonstrated a significant speed improvement, whereas ALI were significantly slower in the second run. Regarding usability, CLI were preferred over ALI due to lighter weight and easier handling. Nevertheless, participants valued ALI’s additional degrees of freedom. Conclusion Using new motorized ALI in the E-BLUS examination by laparoscopic novices led to a worse performance compared to CLI. An explanation could be that participants felt overwhelmed by ALI and that ALI have an own distinct learning curve. As participants valued ALI’s additional degrees of freedom, however, a future application of ALI could be for training purposes, ideally in combination with CLI. Electronic supplementary material The online version of this article (10.1007/s00464-020-08086-2) contains supplementary material, which is available to authorized users.
Collapse
|
7
|
Vigneswaran HT, Dobbs RW, Crivellaro S. AUTHOR REPLY. Urology 2019; 132:128-129. [DOI: 10.1016/j.urology.2019.05.052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Accepted: 05/06/2019] [Indexed: 10/25/2022]
|