1
|
Rovira-Gay C, Argilés M, Mestre C, Vinuela-Navarro V, Pujol J. Does the subjective response during the measurement of fusional reserves affect the clinical diagnosis? Ophthalmic Physiol Opt 2024; 44:1354-1362. [PMID: 39250172 DOI: 10.1111/opo.13384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 08/13/2024] [Accepted: 08/14/2024] [Indexed: 09/10/2024]
Abstract
INTRODUCTION Fusional reserves differ with the method of measurement. The goal of this study was to compare the subjective and objective responses during the measurement of positive and negative fusional reserves using both step and ramp methods. METHODS A haploscopic system was used to measure fusional reserves. Eye movements were recorded using an EyeLink 1000 Plus eye tracker (SR Research). The stimulus disparity was changed to either mimic a prism bar (steps) or a Risley prism (ramp). Subjective responses were obtained by pressing a key on the keyboard, whereas objective break and recovery points were determined offline using a custom algorithm coded in Matlab. RESULTS Thirty-three adults participated in this study. For the ramp method, the subjective and objective responses were similar for the negative (break and recovery points (t(32) = -0.82, p = 0.42) and (t(32) = 0.42, p = 0.67), respectively) and positive fusional reserves (break and recovery points (U = -1.34, p = 0.18) and t(19) = -0.25, p = 0.81), respectively). For the step method, no significant differences in positive fusional reserves were observed when measured subjectively and objectively for the break (t(32) = 1.27, p = 0.21) or the recovery point (U = -2.02, Bonferroni-adjusted p = 0.04). For the negative fusional reserve, differences were not significant for either the break or recovery points (U = -0.10, p = 0.92 and t(19) = 1.17, p = 0.26, respectively). CONCLUSION Subjective and objective responses exhibited good agreement when measured with the ramp and step methods.
Collapse
Affiliation(s)
- Cristina Rovira-Gay
- Centre for Sensors, Instruments, and Systems Development (CD6), Universitat Politècnica de Catalunya-BarcelonaTech (UPC), Barcelona, Spain
| | - Marc Argilés
- Centre for Sensors, Instruments, and Systems Development (CD6), Universitat Politècnica de Catalunya-BarcelonaTech (UPC), Barcelona, Spain
| | - Clara Mestre
- Centre for Sensors, Instruments, and Systems Development (CD6), Universitat Politècnica de Catalunya-BarcelonaTech (UPC), Barcelona, Spain
| | - Valldeflors Vinuela-Navarro
- Centre for Sensors, Instruments, and Systems Development (CD6), Universitat Politècnica de Catalunya-BarcelonaTech (UPC), Barcelona, Spain
| | - Jaume Pujol
- Centre for Sensors, Instruments, and Systems Development (CD6), Universitat Politècnica de Catalunya-BarcelonaTech (UPC), Barcelona, Spain
| |
Collapse
|
2
|
Sangoi A, Scheiman M, Yaramothu C, Santos EM, Gohel S, Alvarez TL. Convergence Insufficiency Neuro-Mechanism Adult Population Study: Phoria Adaptation Results. Invest Ophthalmol Vis Sci 2021; 62:19. [PMID: 34406329 PMCID: PMC8374988 DOI: 10.1167/iovs.62.10.19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to compare changes in phoria adaptation between young adult binocularly normal controls (BNCs) and participants with symptomatic convergence insufficiency (CI), who were randomized to either office-based vergence accommodative therapy (OBVAT) or office-based placebo therapy (OBPT). Methods In the double-masked randomized clinical trial, 50 BNC and 50 CI participants were randomized to the following therapeutic interventions: OBVAT or OBPT with home reinforcement for 12 one-hour office sessions. A 6∆ base-out and 6∆ base-in phoria adaptation experiment at near (40 cm) was conducted using the flashed Maddox rod technique at baseline and at outcome. Measurements included the rate and the magnitude of phoria adaptation. Results At baseline, BNC and CI participants had significantly different rates and magnitudes of base-in and base-out phoria adaptation (P < 0.001). When comparing the outcome to baseline measurements, significant main effect differences in longitudinal measurements were observed for the magnitude and the rate of phoria adaptation for both base-out and base-in experiments (P < 0.05). For the magnitude and rate of phoria adaptation, post hoc analyses using paired t-tests revealed that the CI group administered the OBVAT intervention exhibited a significant increase in the magnitude and rate of phoria adaptation compared to baseline for both base-in and base-out phoria adaptation (P < 0.01) but not for those administered OBPT. Conclusions Phoria adaptation is significantly different at baseline between those with normal binocular vision and symptomatic CI participants. OBVAT significantly improves the rate and magnitude of both base-out and base-in phoria adaptation at near compared to OBPT. Results have clinical implications for new therapeutic interventions.
Collapse
Affiliation(s)
- Ayushi Sangoi
- Biomedical Engineering, New Jersey Institute of Technology, Newark, New Jersey, United States
| | - Mitchell Scheiman
- Pennsylvania College of Optometry, Salus University, Philadelphia, Pennsylvania, United States
| | - Chang Yaramothu
- Biomedical Engineering, New Jersey Institute of Technology, Newark, New Jersey, United States.,School of Applied Engineering and Technology, New Jersey Institute of Technology, Newark, New Jersey, United States
| | - Elio M Santos
- Biomedical Engineering, New Jersey Institute of Technology, Newark, New Jersey, United States
| | - Suril Gohel
- Department of Health Informatics, Rutgers University School of Health Professions, Newark, New Jersey, United States
| | - Tara L Alvarez
- Biomedical Engineering, New Jersey Institute of Technology, Newark, New Jersey, United States
| |
Collapse
|
3
|
Alvarez TL, Scheiman M, Morales C, Gohel S, Sangoi A, Santos EM, Yaramothu C, d'Antonio-Bertagnolli JV, Li X, Biswal BB. Underlying neurological mechanisms associated with symptomatic convergence insufficiency. Sci Rep 2021; 11:6545. [PMID: 33753864 PMCID: PMC7985149 DOI: 10.1038/s41598-021-86171-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Accepted: 02/22/2021] [Indexed: 11/10/2022] Open
Abstract
Convergence insufficiency (CI) is the most common binocular vision problem, associated with blurred/double vision, headaches, and sore eyes that are exacerbated when doing prolonged near work, such as reading. The Convergence Insufficiency Neuro-mechanism Adult Population Study (NCT03593031) investigates the mechanistic neural differences between 50 binocularly normal controls (BNC) and 50 symptomatic CI participants by examining the fast and slow fusional disparity vergence systems. The fast fusional system is preprogrammed and is assessed with convergence peak velocity. The slow fusional system optimizes vergence effort and is assessed by measuring the phoria adaptation magnitude and rate. For the fast fusional system, significant differences are observed between the BNC and CI groups for convergence peak velocity, final position amplitude, and functional imaging activity within the secondary visual cortex, right cuneus, and oculomotor vermis. For the slow fusional system, the phoria adaptation magnitude and rate, and the medial cuneus functional activity, are significantly different between the groups. Significant correlations are observed between vergence peak velocity and right cuneus functional activity (p = 0.002) and the rate of phoria adaptation and medial cuneus functional activity (p = 0.02). These results map the brain-behavior of vergence. Future therapeutic interventions may consider implementing procedures that increase cuneus activity for this debilitating disorder.
Collapse
Affiliation(s)
- Tara L Alvarez
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA.
| | - Mitchell Scheiman
- Pennsylvania College of Optometry, Salus University, Philadelphia, PA, USA
| | - Cristian Morales
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| | - Suril Gohel
- Department of Health Informatics, Rutgers University School of Health Professions, Newark, NJ, USA
| | - Ayushi Sangoi
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| | - Elio M Santos
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| | - Chang Yaramothu
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| | | | - Xiaobo Li
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| | - Bharat B Biswal
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| |
Collapse
|
4
|
Scheiman M, Kulp MT, Cotter SA, Lawrenson JG, Wang L, Li T. Interventions for convergence insufficiency: a network meta-analysis. Cochrane Database Syst Rev 2020; 12:CD006768. [PMID: 33263359 PMCID: PMC8092638 DOI: 10.1002/14651858.cd006768.pub3] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Convergence insufficiency is a common binocular vision disorder in which the eyes have a strong tendency to drift outward (exophoria) with difficulty turning the eyes inward when reading or doing close work. OBJECTIVES To assess the comparative effectiveness and relative ranking of non-surgical interventions for convergence insufficiency through a systematic review and network meta-analysis (NMA). SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, PubMed and three trials registers up to 20 September 2019. SELECTION CRITERIA We included randomized controlled trials (RCTs) examining any form of non-surgical intervention versus placebo, no treatment, sham treatment, or other non-surgical interventions. Participants were children and adults with symptomatic convergence insufficiency. DATA COLLECTION AND ANALYSIS We followed standard Cochrane methodology. We performed NMAs separately for children and adults. MAIN RESULTS We included 12 trials (six in children and six in adults) with a total of 1289 participants. Trials evaluated seven interventions: 1) office-based vergence/accommodative therapy with home reinforcement; 2) home-based pencil/target push-ups; 3) home-based computer vergence/accommodative therapy; 4) office-based vergence/accommodative therapy alone; 5) placebo vergence/accommodative therapy or other placebo intervention; 6) prism reading glasses; and 7) placebo reading glasses. Six RCTs in the pediatric population randomized 968 participants. Of these, the Convergence Insufficiency Treatment Trial (CITT) Investigator Group completed four RCTs with 737 participants. All four CITT RCTs were rated at low risk of bias. Diagnostic criteria and outcome measures were identical or similar among these trials. The four CITT RCTs contributed data to the pediatric NMA, incorporating interventions 1, 2, 3 and 5. When treatment success was defined by a composite outcome requiring both clinical measures of convergence to be normal, and also show a pre-specified magnitude of improvement, we found high-certainty evidence that office-based vergence/accommodative therapy with home reinforcement increases the chance of a successful outcome, compared with home-based computer vergence/accommodative therapy (risk ratio (RR) 1.96, 95% confidence interval (CI) 1.32 to 2.94), home-based pencil/target push-ups (RR 2.86, 95% CI 1.82 to 4.35); and placebo (RR 3.04, 95% CI 2.32 to 3.98). However, there may be no evidence of any treatment difference between home-based computer vergence/accommodative therapy and home-based pencil/target push-ups (RR 1.44, 95% CI 0.93 to 2.24; low-certainty evidence), or between either of the two home-based therapies and placebo therapy, for the outcome of treatment success. When treatment success was defined as the composite convergence and symptom success outcome, we found moderate-certainty evidence that participants who received office-based vergence/accommodative therapy with home reinforcement were 5.12 (95% CI 2.01 to 13.07) times more likely to achieve treatment success than those who received placebo therapy. We found low-certainty evidence that participants who received office-based vergence/accommodative therapy with home reinforcement might be 4.41 (95% CI 1.26 to 15.38) times more likely to achieve treatment success than those who received home-based pencil push-ups, and 4.65 (95% CI 1.23 to 17.54) times more likely than those who received home-based computer vergence/accommodative therapy. There was no evidence of any treatment difference between home-based pencil push-ups and home-based computer vergence/accommodative therapy, or between either of the two home-based therapies and placebo therapy. One RCT evaluated the effectiveness of base-in prism reading glasses in children. When base-in prism reading glasses were compared with placebo reading glasses, investigators found no evidence of a difference in the three outcome measures of near point convergence (NPC), positive fusional vergence (PFV), or symptom scores measured by the Convergence Insufficiency Symptom Survey (CISS). Six RCTs in the adult population randomized 321 participants. We rated only one RCT at low risk of bias. Because not all studies of adults included composite success data, we could not conduct NMAs for treatment success. We thus were limited to comparing the mean difference (MD) between interventions for improving NPC, PFV, and CISS scores individually using data from three RCTs (107 participants; interventions 1, 2, 4 and 5). Compared with placebo treatment, office-based vergence accommodative therapy was relatively more effective in improving PFV (MD 16.73, 95% CI 6.96 to 26.60), but there was no evidence of a difference for NPC or the CISS score. There was no evidence of difference for any other comparisons for any outcomes. One trial evaluated base-in prism glasses prescribed for near-work activities and found that the prism glasses group had fewer symptoms compared with the placebo glasses group at three months (MD -8.9, 95% CI -11.6 to -6.3). The trial found no evidence of a difference with this intervention in NPC or PFV. No adverse effects related to study treatments were reported for any of the included studies. Excellent adherence was reported for office-based vergence/accommodative therapy (96.6% or higher) in two trials. Reported adherence with home-based therapy was less consistent, with one study reporting decreasing adherence over time (weeks 7 to 12) and lower completion rates with home-based pencil/target push-ups. AUTHORS' CONCLUSIONS Current research suggests that office-based vergence/accommodative therapy with home reinforcement is more effective than home-based pencil/target push-ups or home-based computer vergence/accommodative therapy for children. In adults, evidence of the effectiveness of various non-surgical interventions is less clear.
Collapse
Affiliation(s)
| | - Marjean T Kulp
- College of Optometry, The Ohio State University, Columbus, Ohio, USA
| | - Susan A Cotter
- Southern California College of Optometry, Fullerton, California, USA
| | - John G Lawrenson
- Centre for Applied Vision Research, School of Health Sciences, City University of London, London, UK
| | - Lin Wang
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Tianjing Li
- Department of Ophthalmology, University of Colorado Denver Anschutz Medical Campus, Aurora, CO, USA
| |
Collapse
|
5
|
Morales C, Gohel S, Scheiman M, Li X, Santos EM, Sangoi A, Alvarez TL. Test-retest of a phoria adaptation stimulus-induced functional MRI experiment. J Vis 2020; 20:17. [PMID: 32797193 PMCID: PMC7438664 DOI: 10.1167/jov.20.8.17] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
This study was designed to identify the neural substrates activated during a phoria adaptation task using functional magnetic resonance imaging (MRI) in young adults with normal binocular vision and to test the repeatability of the fMRI measurements for this protocol. The phoria adaptation task consisted of a block protocol of 90 seconds of near visual crossed fixation followed by 90 seconds of far visual uncrossed fixation, repeated three times; the data were collected during two different experimental sessions. Results showed that the oculomotor vermis, cuneus, and primary visual cortex had the greatest functional activity within the regions of interest studied when stimulated by the phoria adaptation task. The oculomotor vermis functional activity had an intraclass correlation coefficient (ICC) of 0.3, whereas the bilateral cuneus and primary visual cortex had good ICC results of greater than 0.6. These results suggest that the sustained visual fixation task described within this study reliably activates the neural substrates of phoria adaptation. This protocol establishes a methodology that can be used in future longitudinal studies investigating therapeutic interventions that may modify phoria adaptation.
Collapse
Affiliation(s)
- Cristian Morales
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| | - Suril Gohel
- Department of Health Informatics, Rutgers University School of Health Professions, Newark, NJ, USA
| | - Mitchell Scheiman
- Pennsylvania College of Optometry, Salus University, Philadelphia, PA, USA
| | - Xiaobo Li
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| | - Elio M Santos
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| | - Ayushi Sangoi
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| | - Tara L Alvarez
- Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, USA
| |
Collapse
|
6
|
Alvarez TL, Scheiman M, Santos EM, Morales C, Yaramothu C, D’Antonio-Bertagnolli JV, Biswal BB, Gohel S, Li X. The Convergence Insufficiency Neuro-mechanism in Adult Population Study (CINAPS) Randomized Clinical Trial: Design, Methods, and Clinical Data. Ophthalmic Epidemiol 2020; 27:52-72. [PMID: 31640452 PMCID: PMC6944764 DOI: 10.1080/09286586.2019.1679192] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 09/17/2019] [Accepted: 10/07/2019] [Indexed: 01/28/2023]
Abstract
Purpose: To describe the design and methodology of the Convergence Insufficiency Neuro-mechanism in Adult Population Study (CINAPS), the first randomized clinical trial (RCT) studying young adults with symptomatic convergence insufficiency (CI) using a combination of traditional clinical tests, objective eye movement recordings, and functional brain activities as outcome measures.Methods: In this double-masked RCT, binocularly normal controls (BNC) (N = 50) and CI patients (N = 50) are randomized into office-based vergence/accommodative therapy (OBVAT) or office-based placebo therapy (OBPT). Outcome measures included clinical signs and symptoms, phoria adaptation, forced fixation disparity curves, binocular rivalry, vergence and saccadic objective eye movements, and task-induced functional brain activities. This study is registered on ClinicalTrials.gov NCT03593031.Results: No significant baseline differences are observed between the BNC (p > .4) or CI (p > .3) participants assigned to OBVAT or OBPT for age, near point of convergence (NPC), positive fusional vergence (PFV), phoria at distance and near, amplitude of accommodation, or the Convergence Insufficiency Symptom Survey (CISS). Significant differences are observed between the CI and BNC cohorts at baseline measurements for NPC, PFV, difference in phoria from far to near, amplitude of accommodation, and CISS (p < .001). For the CI patients, 26% had a comorbidity of accommodation insufficiency, and 16% self-reported ADHD.Conclusion: Features of the study design include the following: standardized diagnostic and office-based therapeutic intervention, placebo treatment arm, masked clinical outcome examinations, objective eye movement recordings, functional imaging, phoria adaptation, fixation disparity curves and binocular rivalry measurements.
Collapse
Affiliation(s)
- Tara L. Alvarez
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, USA
| | - Mitchell Scheiman
- Pennsylvania College of Optometry, Salus University, Elkins Park, USA
| | - Elio M. Santos
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, USA
| | - Cristian Morales
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, USA
| | - Chang Yaramothu
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, USA
| | | | - Bharat B. Biswal
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, USA
| | - Suril Gohel
- Department of Health Informatics, Rutgers University School of Health Professions, Newark, USA
| | - Xiaobo Li
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, USA
| |
Collapse
|
7
|
Schroth V, Joos R, Alshuth E, Jaschinski W. Effects of aligning prisms on the objective and subjective fixation disparity in far distance. J Eye Mov Res 2019; 12. [PMID: 33828739 PMCID: PMC7880133 DOI: 10.16910/jemr.12.4.8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Fixation disparity (FD) refers to a suboptimal condition of binocular vision. The oculomotor aspect of FD refers to a misadjustment in the vergence angle between the two visual axes that is measured in research with eye trackers (objective fixation disparity, oFD). The sensory aspect is psychophysically tested using dichoptic nonius lines (subjective fixation disparity, sFD). Some optometrists use nonius tests to determine the prisms for constant wear aiming to align the eyes. However, they do not (yet) use eye trackers. We investigate the effect of aligning prisms on oFD and sFD for 60 sec exposure duration of prisms determined with the clinically established Cross test in far distance vision. Without prisms, both types of FD were correlated with the aligning prism, while with prisms the FD was close to zero (these analyses included all base-in and base-out cases). The effect of base-in prisms on oFD was proportional to the amount of the aligning prism for the present 60 sec exposure, similar as for the 2- 5 sec exposure in Schmid et al. (2018). Thus, within 1 minute of prism exposure, no substantial vergence adaptation seems to occur in the present test conditions. Further studies may investigate intra-individual responses to different exposure times of aligning prisms in both prism directions.
Collapse
Affiliation(s)
| | - Roland Joos
- FHNW, Institute of Optometry, Olten, Switzerland
| | - Ewald Alshuth
- Leibniz Institute for Working Environment and Human Factors, Dortmund, Germany
| | | |
Collapse
|
8
|
Yaramothu C, Jaswal RS, Alvarez TL. Target Eccentricity and Form Influences Disparity Vergence Eye Movements Responses: A Temporal and Dynamic Analysis. J Eye Mov Res 2019. [PMID: 32190205 PMCID: PMC7079726 DOI: 10.16910/jemr.12.4.7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
This study sought to investigate whether stimulation to the fovea or the parafovea with different color combinations influenced the temporal and dynamic features of 4° disparity vergence step responses. Twelve unique types of stimuli were displayed within a haploscope presented along the participant's midsagittal plane. Vergence eye movement responses from fifteen naïve participants were recorded using video-based infrared eye tracking instrumentation. Latency and peak velocity from left and right eye movement responses were quantified. Results show that the type of stimulus projection (foveal versus parafoveal) significantly (p<0.001) influences the vergence response latency but did not impact peak velocity. Vergence responses to eccentric circles with 6° eccentricity targeting the parafovea resulted in a significantly faster response latency compared to vergence responses to a cross with 2° eccentricity stimuli targeting the fovea. Results have implications for the stimulus design of a variety of applications from virtual reality to vision therapy interventions.
Collapse
|
9
|
Yaramothu C, Jaswal RS, Alvarez TL. Target Eccentricity and Form Influences Disparity Vergence Eye Movements Responses: A Temporal and Dynamic Analysis. J Eye Mov Res 2019; 12:7. [PMID: 32190205 PMCID: PMC7079726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Indexed: 11/11/2023] Open
Abstract
This study sought to investigate whether stimulation to the fovea or the parafovea with different color combinations influenced the temporal and dynamic features of 4° disparity vergence step responses. Twelve unique types of stimuli were displayed within a haploscope presented along the participant's midsagittal plane. Vergence eye movement responses from fifteen naïve participants were recorded using video-based infrared eye tracking instrumentation. Latency and peak velocity from left and right eye movement responses were quantified. Results show that the type of stimulus projection (foveal versus parafoveal) significantly (p<0.001) influences the vergence response latency but did not impact peak velocity. Vergence responses to eccentric circles with 6° eccentricity targeting the parafovea resulted in a significantly faster response latency compared to vergence responses to a cross with 2° eccentricity stimuli targeting the fovea. Results have implications for the stimulus design of a variety of applications from virtual reality to vision therapy interventions.
Collapse
|
10
|
Semmlow JL, Yaramothu C, Alvarez TL. Dynamics of the Disparity Vergence Fusion Sustain Component. J Eye Mov Res 2019; 12:11. [PMID: 32318253 PMCID: PMC7173722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Indexed: 11/11/2023] Open
Abstract
The stereotypical vergence response to a step stimulus consists of two dynamic components: a high velocity fusion initiating component followed by a slower component that may mediate sustained fusion. The initial component has been well-studied and is thought to be controlled by an open-loop mechanism. Less is known about the slow, or fusion sustaining component except that it must be feedback controlled to achieve the positional precision of sustained fusion. Given the delays in disparity vergence control, a feedback control system is likely to exhibit oscillatory behavior. Vergence responses to 4 deg step changes in target position were recorded in eight subjects. The slow component of each response was isolated manually using interactive graphics and the frequency spectrum determined. The frequency spectra of all isolated slow vergence movements showed a large low frequency peak between 1.0 and 2.0 Hz and one or more higher frequency components. The higher frequency components were found to be harmonics of the low frequency oscillation. A feedback model of the slow component was developed consisting of a time delay, an integral/derivative controller and an oculomotor plant based on Robinson's model. Model simulations showed that a direction dependent asymmetry in the derivative element was primarily responsible for the higher frequency harmonic components. Simulations also showed that the base frequencies are primarily dependent on the time delay in the feedback control system. The fact that oscillatory behavior was found in all subjects provides strong support that the slow, fusion sustaining component is mediated by a feedback system.
Collapse
|
11
|
Przekoracka-Krawczyk A, Michalak KP, Pyżalska P. Deficient vergence prism adaptation in subjects with decompensated heterophoria. PLoS One 2019; 14:e0211039. [PMID: 30657792 PMCID: PMC6338415 DOI: 10.1371/journal.pone.0211039] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2018] [Accepted: 01/07/2019] [Indexed: 11/26/2022] Open
Abstract
Vergence prism adaptability was evaluated in subjects with high symptomatic and asymptomatic heterophoria and compared to individuals with a heterophoria within normal range (the control group). A computer haploscope was used to measure phoria values and changes in the eye position after introducing 6 prism diopters base out in front of the right eye. Phoria values were measured with a nonius paradigm every minute for a period of 10 minutes during adaptation. The results showed that subjects with symptomatic heterophoria are characterized by a lower rate of prism adaptation and adapted to a smaller extent with respect to the control group. The group with high but asymptomatic heterophoria showed prolonged adaptation time but after several minutes of binocular viewing the subjects were able to adapt to the prism to a level similar to the control group. These findings suggest that an impairment in the slow vergence control system may be responsible for the inability to fully reduce vergence effort, which results in poor vergence ranges and asthenopic symptoms during prolonged viewing.
Collapse
Affiliation(s)
- Anna Przekoracka-Krawczyk
- Laboratory of Vision Science and Optometry, Faculty of Physics, Adam Mickiewicz University, Poznań, Poland
- Vision and Neuroscience Laboratory, NanoBioMedical Centre, Adam Mickiewicz University, Poznań, Poland
- * E-mail:
| | - Krzysztof Piotr Michalak
- Laboratory of Vision Science and Optometry, Faculty of Physics, Adam Mickiewicz University, Poznań, Poland
- Vision and Neuroscience Laboratory, NanoBioMedical Centre, Adam Mickiewicz University, Poznań, Poland
| | - Paulina Pyżalska
- Laboratory of Vision Science and Optometry, Faculty of Physics, Adam Mickiewicz University, Poznań, Poland
| |
Collapse
|