1
|
Wu P, Ocak PE, Wang D, Ocak U, Xu S, Li Y, Zhang T, Shi H. Endovascular Treatment of Ruptured Tiny Intracranial Aneurysms with Low-Profile Visualized Intraluminal Support Device. J Stroke Cerebrovasc Dis 2018; 28:330-337. [PMID: 30391328 DOI: 10.1016/j.jstrokecerebrovasdis.2018.09.052] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Revised: 08/30/2018] [Accepted: 09/30/2018] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND Ruptured tiny intracranial aneurysms (TIAs) have been challenging both for endovascular and neurosurgical interventions. Thus, we aimed to evaluate the safety and efficacy of low-profile visualized intraluminal support (LVIS) device in the treatment of ruptured TIAs (rTIAs). MATERIAL AND METHODS Among 761 intracranial aneurysms which were treated either surgically or endovascularly, 32 rTIAs underwent stent-assisted coiling with LVIS device between 2014 and 2017. Patient data were reviewed retrospectively. Clinical and radiological outcomes were recorded at discharge and mid-term follow-up. RESULTS Mean patient ages were 53 ± 14.5 years. Mean aneurysm size was 2.28 ± .53 mm (range, 1-2.9 mm) with a mean dome:neck ratio of 1.08 (range, .75-2.14). The LVIS stents were successfully implanted in all patients. Mean follow-up period was 9.3 ± 1.9 months (range, 6-15 months). Immediate angiographic evaluation demonstrated complete occlusion in 13 (40.6%) patients, while neck remnant and residual sac were observed in 12 (37.5%) and 7 (21.9%), respectively. All patients had moderate disability (mRS 2-3) at discharge. Number of aneurysms with complete occlusion significantly increased and 82.1% of the patients (23 of 28) demonstrated complete occlusion at follow-up (P = .0015). Among these, 27 had good outcome (mRS 0-1; 96.9%) with significant improvement compared to discharge (P = .0001). There was no recurrence or enlargement of the residual aneurysms. Additionally, there were no procedure-related complications except the one (3.6%) showing asymptomatic stenosis of the posterior cerebral artery in follow-up imagings. CONCLUSIONS Stent-assisted coiling of rTIAs with LVIS device provides high rates of technical success and complete occlusion at mid-term follow-up with an excellent safety profile.
Collapse
Affiliation(s)
- Pei Wu
- Department of Neurosurgery, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
| | - Pinar Eser Ocak
- Loma Linda University School of Medicine, Loma Linda, California,.
| | - Dianhong Wang
- Department of Neurosurgery, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
| | - Umut Ocak
- Loma Linda University School of Medicine, Loma Linda, California,.
| | - Shancai Xu
- Department of Neurosurgery, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
| | - Yuchen Li
- Department of Neurosurgery, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
| | - Tongyu Zhang
- Department of Neurosurgery, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
| | - Huaizhang Shi
- Department of Neurosurgery, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
| |
Collapse
|
2
|
Cagnazzo F, Cappucci M, Lefevre PH, Dargazanli C, Gascou G, Morganti R, Mazzotti V, di Carlo D, Perrini P, Mantilla D, Riquelme C, Bonafe A, Costalat V. Treatment of Intracranial Aneurysms with Self-Expandable Braided Stents: A Systematic Review and Meta-Analysis. AJNR Am J Neuroradiol 2018; 39:2064-2069. [PMID: 30262643 DOI: 10.3174/ajnr.a5804] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Accepted: 07/30/2018] [Indexed: 11/07/2022]
Abstract
BACKGROUND The safety and efficacy of treatment with self-expandable braided stents (LEO and LVIS) required further investigation. PURPOSE Our aim was to analyze the outcomes after treatment with braided stents. DATA SOURCES A systematic search of 3 databases was performed for studies published from 2006 to 2017. STUDY SELECTION According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting patients treated with LEO or LVIS stents. DATA ANALYSIS Random-effects meta-analysis was used to pool the following: aneurysm occlusion rate, complications, and neurologic outcomes. DATA SYNTHESIS Thirty-five studies evaluating 1426 patients treated with braided stents were included in this meta-analysis. Successful stent delivery and complete aneurysm occlusion were 97% (1041/1095; 95% CI, 95%-98%) (I2 = 44%) and 88.3% (1097/1256; 95% CI, 85%-91%) (I2 = 72%), respectively. Overall, treatment-related complications were 7.4% (107/1317; 95% CI, 5%-9%) (I2 = 44%). Ischemic/thromboembolic events (48/1324 = 2.4%; 95% CI, 1.5%-3.4%) (I2 = 27%) and in-stent thrombosis (35/1324 = 1.5%; 95% CI, 0.6%-1.7%) (I2 = 0%) were the most common complications. Treatment-related morbidity was 1.5% (30/1324; 95% CI, 0.9%-2%) and was comparable between the LEO and LVIS groups. Complication rates between the anterior (29/322 = 8.8%; 95% CI, 3.4%-12%) (I2 = 41%) versus posterior circulation (10/84 = 10.5%; 95% CI, 4%-16%) (I2 = 0%) and distal (30/303 = 8%; 95% CI, 4.5%-12%) (I2 = 48%) versus proximal aneurysms (14/153 = 9%; 95% CI, 3%-13%) (I2 = 46%) were comparable (P > .05). LIMITATIONS Limitations were selection and publication biases. CONCLUSIONS In this analysis, treatment with the LEO and LVIS stents was relatively safe and effective. The most common complications were periprocedural thromboembolisms and in-stent thrombosis. The rate of complications was comparable among anterior and posterior circulation aneurysms, as well as for proximal and distally located lesions.
Collapse
Affiliation(s)
- F Cagnazzo
- From the Neuroradiology Department (F.G., M.C., P.-H.L., C.D., G.G., C.R., A.B., V.C.), University Hospital Güi-de-Chauliac, Centre Hospitalier Universitaire de Montpellier, Montpellier, France
| | - M Cappucci
- From the Neuroradiology Department (F.G., M.C., P.-H.L., C.D., G.G., C.R., A.B., V.C.), University Hospital Güi-de-Chauliac, Centre Hospitalier Universitaire de Montpellier, Montpellier, France
| | - P-H Lefevre
- From the Neuroradiology Department (F.G., M.C., P.-H.L., C.D., G.G., C.R., A.B., V.C.), University Hospital Güi-de-Chauliac, Centre Hospitalier Universitaire de Montpellier, Montpellier, France
| | - C Dargazanli
- From the Neuroradiology Department (F.G., M.C., P.-H.L., C.D., G.G., C.R., A.B., V.C.), University Hospital Güi-de-Chauliac, Centre Hospitalier Universitaire de Montpellier, Montpellier, France
| | - G Gascou
- From the Neuroradiology Department (F.G., M.C., P.-H.L., C.D., G.G., C.R., A.B., V.C.), University Hospital Güi-de-Chauliac, Centre Hospitalier Universitaire de Montpellier, Montpellier, France
| | - R Morganti
- Section of Statistics (R.M., V.M.), University Hospital of Pisa, Pisa, Italy
| | - V Mazzotti
- Section of Statistics (R.M., V.M.), University Hospital of Pisa, Pisa, Italy
| | - D di Carlo
- Department of Neurosurgery (D.d.C., P.P.), University of Pisa, Pisa, Italy
| | - P Perrini
- Department of Neurosurgery (D.d.C., P.P.), University of Pisa, Pisa, Italy
| | - D Mantilla
- Neuroradiology Department (D.M.), Clinic FOSCAL, Universidad Autonoma de Bucaramanga, Andrés Bello National University, Santiago, Chili
| | - C Riquelme
- From the Neuroradiology Department (F.G., M.C., P.-H.L., C.D., G.G., C.R., A.B., V.C.), University Hospital Güi-de-Chauliac, Centre Hospitalier Universitaire de Montpellier, Montpellier, France
| | - A Bonafe
- From the Neuroradiology Department (F.G., M.C., P.-H.L., C.D., G.G., C.R., A.B., V.C.), University Hospital Güi-de-Chauliac, Centre Hospitalier Universitaire de Montpellier, Montpellier, France
| | - V Costalat
- From the Neuroradiology Department (F.G., M.C., P.-H.L., C.D., G.G., C.R., A.B., V.C.), University Hospital Güi-de-Chauliac, Centre Hospitalier Universitaire de Montpellier, Montpellier, France
| |
Collapse
|
3
|
Cheung NK, Chiu AHY, Cheung AK, Wenderoth JD. Long-term follow-up of aneurysms treated electively with woven stent-assisted coiling. J Neurointerv Surg 2017; 10:669-674. [DOI: 10.1136/neurintsurg-2017-013402] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Revised: 11/02/2017] [Accepted: 11/03/2017] [Indexed: 11/03/2022]
Abstract
BackgroundPreliminary short-term results for stent-assisted coil embolization (SACE) using woven/braided stents have been promising. However, evidence supporting mid- to long-term efficacy and durability is lacking.ObjectiveTo report the long-term results for the durability of elective intracranial aneurysms treated with woven stents.Materials and methodsBetween May 2012 and May 2015, 98 consecutive patients with 103 aneurysms underwent elective woven SACE across three Australian neurovascular centres. All patients had immediate, 6- and 18-month clinical and radiological follow-up. Radiological assessment was performed with modified Raymond–Roy occlusion scores based on angiography results, while clinical assessment was based on the modified Rankin Scale.ResultsSix-month follow-up was available in 100 aneurysms, and an 18-month follow-up in 97 aneurysms. Total occlusion rates of 82% were achieved at inception, 82% at 6 months, and 90% at 18 months. Satisfactory occlusion with small neck remnants was present in 17% at inception, 16% at 6 months, and 9% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Intraprocedural thromboembolic events were recorded in 3% and delayed events in 1% (all in patients taking clopidogrel). Aneurysm recurrence occurred in one patient (1%). Technical complications occurred in 5%. The total complication rate was 10%.ConclusionsWoven SACE is safe, efficacious, and durable at long-term 18-month follow-up, with very low recurrence and re-treatment rates. Preliminary results appear better than those for traditional laser-cut stents.
Collapse
|
4
|
Zhang X, Zhong J, Gao H, Xu F, Bambakidis NC. Endovascular treatment of intracranial aneurysms with the LVIS device: a systematic review. J Neurointerv Surg 2016; 9:553-557. [PMID: 27206450 DOI: 10.1136/neurintsurg-2016-012403] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2016] [Revised: 04/27/2016] [Accepted: 05/02/2016] [Indexed: 11/04/2022]
Abstract
OBJECTIVE Despite promising initial results, current knowledge regarding the use of the Low-profile Visualized Intraluminal Support (LVIS) device to treat wide-necked intracranial aneurysms is still limited. Our aim is to evaluate the feasibility, efficacy, and safety of the LVIS device in stent-assisted coiling of intracranial aneurysms. METHODS We conducted a systematic review by searching PubMed, EMBASE, and Cochrane Library for all published studies on the treatment of intracranial aneurysms with the LVIS device up to March 2016. Feasibility was evaluated by the technical success rate during the procedure, efficacy was evaluated by the rate of complete aneurysm occlusion at follow-up angiography, and safety was assessed by procedure-related morbidity and mortality. RESULTS A total of nine studies were included in the analysis, including 384 patients with 390 aneurysms. The overall technical success rate was 96.8% (95% CI 94.4% to 99.1%). The aneurysmal complete occlusion rate was 54.6% (95% CI 31.8% to 77.4%) on immediate control and 84.3% (95% CI 78.9% to 89.7%) at follow-up angiography. Procedural-related morbidity and mortality were 1.4% (95% CI 0.2% to 2.6%) and 0% (95% CI 0%), respectively. The thromboembolic event rate was 4.9% (95% CI 1.9% to 7.9%) and the hemorrhagic event rate was 2.1% (95% CI 0.7% to 3.5%), with 0.9% (95% CI 0% to 1.8%) experiencing neurologic hemorrhagic complications and 1.9% (95% CI 0.5% to 3.2%) experiencing non-neurologic hemorrhagic complications. CONCLUSIONS Our systematic review suggests that endovascular treatment of intracranial aneurysms with the LVIS device is feasible, safe, and effective in the short term. However, the rate of thromboembolic complications is not negligible. Further prospective studies are needed to evaluate the long-term efficacy and safety of the LVIS device.
Collapse
Affiliation(s)
- Xiaoguang Zhang
- Department of Neurosurgery, The First Affiliated Hospital of Henan University, Henan, China
| | - Junjie Zhong
- Department of Neurosurgery, The Affiliated Jiangyin Hospital of Nantong University, Jiangyin, China
| | - Heng Gao
- Department of Neurosurgery, The Affiliated Jiangyin Hospital of Nantong University, Jiangyin, China
| | - Feng Xu
- Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai, China
| | - Nicholas C Bambakidis
- Department of Neurological Surgery, University Hospitals Case Medical Center, Cleveland, Ohio, USA
| |
Collapse
|
5
|
Machi P, Costalat V, Lobotesis K, Ruiz C, Cheikh YB, Eker O, Gascou G, Danière F, Riquelme C, Bonafé A. LEO Baby Stent Use following Balloon-Assisted Coiling: Single- and Dual-Stent Technique--Immediate and Midterm Results of 29 Consecutive Patients. AJNR Am J Neuroradiol 2015; 36:2096-103. [PMID: 26272976 DOI: 10.3174/ajnr.a4413] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Accepted: 03/19/2015] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE We report our preliminary results in terms of safety and efficacy in using the low-profile LEO Baby stent for the treatment of large-neck and complex intracranial aneurysms with balloon-then-stent-assisted coiling and single- or dual-stent-assisted coiling. MATERIALS AND METHODS Clinical and radiologic data of all consecutive patients treated at our institution from September 2012 to October 2013 for an intracranial aneurysm by using a LEO Baby stent were retrospectively analyzed. Immediate and midterm clinical and anatomic follow-up of each patient is reported. RESULTS Twenty-nine patients with 29 aneurysms were treated with LEO Baby stents at our institution. The mean age of patients was 48 years; 20 patients were women (71%). One patient was treated in the acute phase of a subarachnoid hemorrhage. In 8 procedures, a double-lumen-catheter balloon was used for balloon-then-stent-assisted coiling. In 3 cases, a LEO Baby stent was used in a Y-, T-, and telescopic dual-stent configuration. In 18 cases, a single LEO Baby stent was used. In 2 cases, technical failure to deploy the stent resulted in acute parent artery thrombosis. In 3 further cases, thromboembolic complications occurred intraoperatively. MR imaging and angiographic midterm follow-up showed complete aneurysm occlusion for 96% of the followed patients (27/29). Clinical outcome was favorable for all patients followed up. CONCLUSIONS Results obtained in our study by using the LEO Baby stent for balloon-then-stent and single- or dual-stent-assisted coiling of complex and distally located intracranial aneurysms are encouraging. Incomplete or inadequate opening of the device is a potential cause of laminar blood flow alteration and thrombus formation.
Collapse
Affiliation(s)
- P Machi
- From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France
| | - V Costalat
- From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France
| | - K Lobotesis
- Imperial College Healthcare (K.L.), London, UK
| | - C Ruiz
- From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France
| | - Y B Cheikh
- From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France
| | - O Eker
- From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France
| | - G Gascou
- From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France
| | - F Danière
- From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France
| | - C Riquelme
- From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France
| | - A Bonafé
- From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France
| |
Collapse
|
6
|
Technology developments in endovascular treatment of intracranial aneurysms. J Neurointerv Surg 2014; 8:135-44. [DOI: 10.1136/neurintsurg-2014-011475] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2014] [Accepted: 11/04/2014] [Indexed: 11/03/2022]
Abstract
Advances in the management and endovascular treatment of intracranial aneurysms are progressing at a tremendous rate. Developments in novel imaging technology may improve diagnosis, risk stratification, treatment planning, intraprocedural assessment, and follow-up evaluation. Evolution of devices, including microwires, microcatheters, balloons, stents, and novel scaffolding devices, has greatly expanded the potential to treat difficult aneurysms. Although developments in technology have greatly improved the efficiency and efficacy of treatment of neurovascular disorders, novel devices do not always improve outcomes and may be associated with unique complications. As such, it is paramount to have an in-depth understanding of new devices and the implications of their introduction into clinical practice. This review provides an update on developments in endovascular treatment of intracranial aneurysms.
Collapse
|
7
|
Poncyljusz W, Biliński P, Safranow K, Baron J, Zbroszczyk M, Jaworski M, Bereza S, Burke TH. The LVIS/LVIS Jr. stents in the treatment of wide-neck intracranial aneurysms: multicentre registry. J Neurointerv Surg 2014; 7:524-9. [DOI: 10.1136/neurintsurg-2014-011229] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Accepted: 04/28/2014] [Indexed: 11/04/2022]
|
8
|
Dumont TM, Eller JL, Mokin M, Sorkin GC, Levy EI. Advances in Endovascular Approaches to Cerebral Aneurysms. Neurosurgery 2014; 74 Suppl 1:S17-31. [DOI: 10.1227/neu.0000000000000217] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Abstract
Recent advancements in all phases of endovascular aneurysm treatment, including medical therapy, diagnostics, devices, and implants, abound. Advancements in endovascular technologies and techniques have enabled treatment of a wide variety of intracranial aneurysms. In this article, technical advances in endovascular treatment of cerebral aneurysms are discussed, with an effort to incorporate a clinically relevant perspective. Advancements in diagnostic tools, medical therapy, and implants are reviewed and discussed.
Collapse
Affiliation(s)
- Travis M. Dumont
- Department of Neurosurgery,
- Department of Radiology, School of Medicine and Biomedical Sciences,
| | - Jorge L. Eller
- Department of Neurosurgery,
- Department of Radiology, School of Medicine and Biomedical Sciences,
| | - Maxim Mokin
- Department of Neurosurgery,
- Department of Radiology, School of Medicine and Biomedical Sciences,
| | - Grant C. Sorkin
- Department of Neurosurgery,
- Department of Radiology, School of Medicine and Biomedical Sciences,
| | - Elad I. Levy
- Department of Neurosurgery,
- Department of Radiology, School of Medicine and Biomedical Sciences,
- Toshiba Stroke and Vascular Research Center, University at Buffalo, State University of New York
- Department of Neurosurgery, Gates Vascular Institute, Kaleida Health, Buffalo, New York, NY
| |
Collapse
|
9
|
Pritz MB. Geometry of saccular cerebral aneurysms not associated with a branch vessel. J Stroke Cerebrovasc Dis 2013; 23:540-4. [PMID: 23747178 DOI: 10.1016/j.jstrokecerebrovasdis.2013.05.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2013] [Accepted: 05/08/2013] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE Saccular cerebral aneurysms located at nonbranching sites are uncommon. Their distribution, morphological features, and presence of a branch vessel or a tiny perforator(s) separate from the aneurysm neck were investigated. METHODS From a series of 303 microsurgically clipped saccular cerebral aneurysms, 40 aneurysms were identified at sites not related to a branch vessel. RESULTS The distribution of aneurysms at nonbranching sites was internal carotid: 21 of 40 (52.5%); main stem of the middle cerebral artery/secondary branch of the middle cerebral artery: 6 of 40 (15%); anterior cerebral artery: 1 of 40 (2.5%); pericallosal artery: 1 of 40 (2.5%); pericallosal/callosal marginal: 3 of 40 (7.5%); vertebral artery: 1 of 40 (2.5%); posterior cerebral artery: 1 of 40 (2.5%); posterior cerebral artery/secondary branch of the posterior cerebral artery: 1 of 40 (2.5%); anterior inferior cerebellar artery: 1 of 40 (2.5%); and distal posterior inferior cerebellar artery: 1 of 40 (2.5%). Branch vessels were seen in 5 cases, and small perforating vessels were observed in 2 instances. CONCLUSIONS Saccular aneurysms occurring at nonbranching sites are uncommon. Their geometry is particularly favorable for flow directed stents and is most amenable to aneurysms located on large-diameter conducting vessels such as the internal carotid, vertebral, and vertebrobasilar vessels. Smaller parent arteries harboring this type of aneurysm will require new technology to maintain patency of these more distal vessels. If endovascular techniques cannot achieve aneurysm sac obliteration, then open craniotomy and aneurysm clipping will provide a satisfactory alternative.
Collapse
Affiliation(s)
- Michael B Pritz
- Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, Indiana.
| |
Collapse
|
10
|
Wallner AK, Broussalis E, Hauser T, Trinka E, Killer-Oberpfalzer M. Coiling after treatment with the woven EndoBridge cerebral aneurysm embolization device. A case report. Interv Neuroradiol 2012; 18:208-12. [PMID: 22681738 DOI: 10.1177/159101991201800214] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2011] [Accepted: 01/29/2012] [Indexed: 11/15/2022] Open
Abstract
Retreatment options after the use of the newly launched Woven EndoBridge cerebral aneurysm embolization device (WEB II) are mostly unknown. Nine months after WEB II implantation, a 55-year-old female patient presented with regrowth of an MCA aneurysm. For the first time, standard balloon-assisted coiling was used to close the regrown aneurysm proximal to the WEB II implant. We report on the feasibility and safety of balloon-assisted coiling after implantation of the WEB II device.
Collapse
Affiliation(s)
- A K Wallner
- Research Institute of Neurointervention, Paracelsus Medical University, Christian Doppler Clinic, Salzburg, Austria.
| | | | | | | | | |
Collapse
|
11
|
Lv X, Li Y, Xinjian Y, Jiang C, Wu Z. Results of endovascular treatment for intracranial wide-necked saccular and dissecting aneurysms using the Enterprise stent: a single center experience. Eur J Radiol 2012; 81:1179-83. [PMID: 21546179 DOI: 10.1016/j.ejrad.2011.03.052] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2010] [Accepted: 03/15/2011] [Indexed: 02/07/2023]
Abstract
OBJECTIVE The aim of the present retrospective study is to compare outcome of the endovascular treatment using the Enterprise stent in intracranial wide-necked saccular and dissecting aneurysms. METHODS Forty-six patients with 50 complex intracranial aneurysms admitted between June 2009 and November 2010 were treated using Enterprise stents. Thirty-one aneurysms were wide-necked saccular, 19 aneurysms dissecting. In 48 cases, aneurysms were occluded by stent-assisted coiling; in 2 cases, by stent alone. RESULTS Among the aneurysms treated with the Enterprise stent, patient sex, aneurysm location, hypertension history and the immediate angiographic results differed significantly between the saccular and dissecting aneurysm groups. However, recurrence rate, clinical follow-up outcomes did not differ significantly between the saccular and dissecting groups. There was 1 (2%) procedure-related complication, which caused death in the saccular group. At mean 9.1-month follow-up, the result was good in all dissecting cases and good in 30 saccular cases. There was 1 recurrence in each group. CONCLUSIONS Enterprise stent is very useful for endovascular embolization of intracranial wide-necked saccular and dissecting aneurysms because it is easy to navigate and place precisely. The overall morbidity and mortality rates were low.
Collapse
Affiliation(s)
- Xianli Lv
- Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
| | | | | | | | | |
Collapse
|