1
|
Ali A, Morris JM, Decker SJ, Huang YH, Wake N, Rybicki FJ, Ballard DH. Clinical situations for which 3D printing is considered an appropriate representation or extension of data contained in a medical imaging examination: neurosurgical and otolaryngologic conditions. 3D Print Med 2023; 9:33. [PMID: 38008795 PMCID: PMC10680204 DOI: 10.1186/s41205-023-00192-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 10/03/2023] [Indexed: 11/28/2023] Open
Abstract
BACKGROUND Medical three dimensional (3D) printing is performed for neurosurgical and otolaryngologic conditions, but without evidence-based guidance on clinical appropriateness. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (SIG) provides appropriateness recommendations for neurologic 3D printing conditions. METHODS A structured literature search was conducted to identify all relevant articles using 3D printing technology associated with neurologic and otolaryngologic conditions. Each study was vetted by the authors and strength of evidence was assessed according to published guidelines. RESULTS Evidence-based recommendations for when 3D printing is appropriate are provided for diseases of the calvaria and skull base, brain tumors and cerebrovascular disease. Recommendations are provided in accordance with strength of evidence of publications corresponding to each neurologic condition combined with expert opinion from members of the 3D printing SIG. CONCLUSIONS This consensus guidance document, created by the members of the 3D printing SIG, provides a reference for clinical standards of 3D printing for neurologic conditions.
Collapse
Affiliation(s)
- Arafat Ali
- Department of Radiology, Henry Ford Health, Detroit, MI, USA
| | | | - Summer J Decker
- Division of Imaging Research and Applied Anatomy, Department of Radiology, University of South Florida Morsani College of Medicine, Tampa, FL, USA
| | - Yu-Hui Huang
- Department of Radiology, University of Minnesota, Minneapolis, MN, USA
| | - Nicole Wake
- Department of Research and Scientific Affairs, GE HealthCare, New York, NY, USA
- Center for Advanced Imaging Innovation and Research, Department of Radiology, NYU Langone Health, New York, NY, USA
| | - Frank J Rybicki
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - David H Ballard
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis, MO, USA.
| |
Collapse
|
2
|
Youn SW, Lee J. From 2D to 4D Phase-Contrast MRI in the Neurovascular System: Will It Be a Quantum Jump or a Fancy Decoration? J Magn Reson Imaging 2020; 55:347-372. [PMID: 33236488 DOI: 10.1002/jmri.27430] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 10/20/2020] [Accepted: 10/21/2020] [Indexed: 12/16/2022] Open
Abstract
Considering the crosstalk between the flow and vessel wall, hemodynamic assessment of the neurovascular system may offer a well-integrated solution for both diagnosis and management by adding prognostic significance to the standard CT/MR angiography. 4D flow MRI or time-resolved 3D velocity-encoded phase-contrast MRI has long been promising for the hemodynamic evaluation of the great vessels, but challenged in clinical studies for assessing intracranial vessels with small diameter due to long scan times and low spatiotemporal resolution. Current accelerated MRI techniques, including parallel imaging with compressed sensing and radial k-space undersampling acquisitions, have decreased scan times dramatically while preserving spatial resolution. 4D flow MRI visualized and measured 3D complex flow of neurovascular diseases such as aneurysm, arteriovenous shunts, and atherosclerotic stenosis using parameters including flow volume, velocity vector, pressure gradients, and wall shear stress. In addition to the noninvasiveness of the phase contrast technique and retrospective flow measurement through the wanted windows of the analysis plane, 4D flow MRI has shown several advantages over Doppler ultrasound or computational fluid dynamics. The evaluation of the flow status and vessel wall can be performed simultaneously in the same imaging modality. This article is an overview of the recent advances in neurovascular 4D flow MRI techniques and their potential clinical applications in neurovascular disease. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY STAGE: 3.
Collapse
Affiliation(s)
- Sung Won Youn
- Department of Radiology, Catholic University of Daegu School of Medicine, Daegu, Korea
| | - Jongmin Lee
- Department of Radiology and Biomedical Engineering, Kyungpook National University School of Medicine, Daegu, Korea
| |
Collapse
|
3
|
Su T, Reymond P, Brina O, Bouillot P, Machi P, Delattre BMA, Jin L, Lövblad KO, Vargas MI. Large Neck and Strong Ostium Inflow as the Potential Causes for Delayed Occlusion of Unruptured Sidewall Intracranial Aneurysms Treated by Flow Diverter. AJNR Am J Neuroradiol 2020; 41:488-494. [PMID: 32054620 DOI: 10.3174/ajnr.a6413] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2019] [Accepted: 12/23/2019] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Flow diverter-induced hemodynamic change plays an important role in the mechanism of intracranial aneurysm occlusion. Our aim was to explore the relationship between aneurysm features and flow-diverter treatment of unruptured sidewall intracranial aneurysms. MATERIALS AND METHODS MR imaging, 4D phase-contrast, was prospectively performed before flow diverter implantation in each patient with unruptured intracranial aneurysm. Two postprocedure follow-ups were scheduled at 6 and 12 months. Responses were grouped according to whether the aneurysms were occluded or remnant. Preprocedural aneurysm geometries and ostium hemodynamics in 38 patients were compared between the 2 groups at 6 and 12 months. Receiver operating characteristic curve analyses were performed for significant geometric and hemodynamic continuous parameters. RESULTS After the 6-month assessment, 21 of 41 intracranial aneurysms were occluded, and 9 additional aneurysms were occluded at 12 months. Geometrically, the ostium maximum diameter was significantly larger in the remnant group at 6 and 12 months (both P < .001). Hemodynamically, the proximal inflow zone was more frequently observed in the remnant group at 6 months. Several preprocedural ostium hemodynamic parameters were significantly higher in the remnant group. As a prediction for occlusion, the areas under the curve of the ostium maximum diameter (for 6 and 12 months), systolic inflow rate ratio (for 6 months), and systolic inflow area (for 12 months) reached 0.843, 0.883, 0.855, and 0.860, respectively. CONCLUSIONS Intracranial aneurysms with a large ostium and strong ostium inflow may need a longer time for occlusion. Preprocedural 4D flow MR imaging can well illustrate ostium hemodynamics and characterize aneurysm treatment responses.
Collapse
Affiliation(s)
- T Su
- From the Department of Interventional Radiology (T.S., L.J.), Beijing Friendship Hospital, Capital Medical University, Beijing, People's Republic of China
| | - P Reymond
- Division of Neuroradiology and Neuro-Interventional Radiology (P.R., O.B., P.M., K.O.L., M.I.V.)
| | - O Brina
- Division of Neuroradiology and Neuro-Interventional Radiology (P.R., O.B., P.M., K.O.L., M.I.V.)
| | - P Bouillot
- and Division of Radiology (B.M.A.D.), University Hospitals of Geneva, Geneva, Switzerland
| | - P Machi
- Division of Neuroradiology and Neuro-Interventional Radiology (P.R., O.B., P.M., K.O.L., M.I.V.)
| | - B M A Delattre
- Department of Quantum Matter Physics (P.B.), University of Geneva, Geneva, Switzerland
| | - L Jin
- From the Department of Interventional Radiology (T.S., L.J.), Beijing Friendship Hospital, Capital Medical University, Beijing, People's Republic of China
| | - K O Lövblad
- Division of Neuroradiology and Neuro-Interventional Radiology (P.R., O.B., P.M., K.O.L., M.I.V.)
| | - M I Vargas
- Division of Neuroradiology and Neuro-Interventional Radiology (P.R., O.B., P.M., K.O.L., M.I.V.)
| |
Collapse
|
4
|
Brina O, Bouillot P, Reymond P, Luthman AS, Santarosa C, Fahrat M, Lovblad KO, Machi P, Delattre BMA, Pereira VM, Vargas MI. How Flow Reduction Influences the Intracranial Aneurysm Occlusion: A Prospective 4D Phase-Contrast MRI Study. AJNR Am J Neuroradiol 2019; 40:2117-2123. [PMID: 31727755 DOI: 10.3174/ajnr.a6312] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Accepted: 09/20/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND AND PURPOSE Flow-diverter stents are widely used for the treatment of wide-neck intracranial aneurysms. Various parameters may influence intracranial aneurysm thrombosis, including the flow reduction induced by flow-diverter stent implantation, which is assumed to play a leading role. However, its actual impact remains unclear due to the lack of detailed intra-aneurysmal flow measurements. This study aimed to clarify this relationship by quantitatively measuring the intra-aneurysmal flow using 4D phase-contrast MR imaging. MATERIALS AND METHODS We acquired prospective pre- and post-stent implantation 4D phase-contrast MR imaging data of a consecutive series of 23 patients treated with flow-diverter stents. Velocity field data were combined with the intraprocedural 3D angiogram vessel geometries for precise intracranial aneurysm extraction and partial volume correction. Intra-aneurysmal hemodynamic modifications were compared with occlusion outcomes at 6 and 12 months. RESULTS The averaged velocities at systole were lower after flow-diverter stent implantation for all patients and ranged from 21.7 ± 7.1 cm/s before to 7.2 ± 2.9 cm/s after stent placement. The velocity reduction was more important for the group of patients with aneurysm thrombosis at 6 months (68.8%) and decreased gradually from 66.2% to 55% for 12-month thrombosis and no thrombosis, respectively (P = .08). CONCLUSIONS We propose an innovative approach to measure intracranial flow changes after flow-diverter stent implantation. We identified a trend between flow reduction and thrombosis outcome that brings a new insight into current understanding of the flow-diversion treatment response.
Collapse
Affiliation(s)
- O Brina
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - P Bouillot
- Department of Quantum Matter Physics (P.B.), University of Geneva, Geneva, Switzerland
| | - P Reymond
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - A S Luthman
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - C Santarosa
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - M Fahrat
- Laboratory for Hydraulic Machines (M.F.), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - K O Lovblad
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - P Machi
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| | - B M A Delattre
- Radiology (B.M.A.D.), Geneva University Hospitals, University of Geneva, Geneva, Switzerland
| | - V M Pereira
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.).,Division of Neuroradiology (V.M.P.).,Department of Medical Imaging (V.M.P.).,Division of Neurosurgery (V.M.P.), Department of Surgery, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada
| | - M I Vargas
- From the Divisions of Neuroradiology (O.B., P.R., A.S.L., C.S., K.O.L., P.M., V.M.P., M.I.V.)
| |
Collapse
|
5
|
Parthasarathy J, Krishnamurthy R, Ostendorf A, Shinoka T, Krishnamurthy R. 3D printing with MRI in pediatric applications. J Magn Reson Imaging 2019; 51:1641-1658. [PMID: 31329332 DOI: 10.1002/jmri.26870] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 07/01/2019] [Accepted: 07/01/2019] [Indexed: 12/12/2022] Open
Abstract
3D printing (3DP) applications for clinical evaluation, preoperative planning, patient and trainee education, and simulation has increased in the past decade. Most of the applications are found in cardiovascular, head and neck, orthopedic, neurological, urological, and oncological surgical cases. This review has three parts. The first part discusses the technical pathway to realizing a physical model, 3DP considerations in pediatric MRI image acquisition, data and resolution requirements, and related structural segmentation and postprocessing steps needed to generalize both virtual and physical models. Standard practices and processing software used in these processes will be assessed. The second part discusses complementary examples in pediatric applications, including cases from cardiology, neuroradiology, neurology, and neurosurgery, head and neck, orthopedics, pelvic and urological applications, oncological applications, and fetal imaging. The third part explores other 3D printing applications and considerations such as using 3DP to develop tissue-specific phantoms and devices for testing in the MR environment, to educate patients and their families, to train clinicians and students, and facility requirements for building a 3DP program. Level of Evidence: 5 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2020;51:1641-1658.
Collapse
Affiliation(s)
| | | | - Adam Ostendorf
- Department of Neurology Nationwide Children's Hospital, Columbus, Ohio, USA
| | - Toshiharu Shinoka
- Department of Cardiothoracic Surgery, Nationwide Children's Hospital, Columbus, Ohio, USA
| | - Rajesh Krishnamurthy
- The Department of Radiology, Nationwide Children's Hospital, Columbus, Ohio, USA
| |
Collapse
|
6
|
Chepelev L, Wake N, Ryan J, Althobaity W, Gupta A, Arribas E, Santiago L, Ballard DH, Wang KC, Weadock W, Ionita CN, Mitsouras D, Morris J, Matsumoto J, Christensen A, Liacouras P, Rybicki FJ, Sheikh A. Radiological Society of North America (RSNA) 3D printing Special Interest Group (SIG): guidelines for medical 3D printing and appropriateness for clinical scenarios. 3D Print Med 2018; 4:11. [PMID: 30649688 PMCID: PMC6251945 DOI: 10.1186/s41205-018-0030-y] [Citation(s) in RCA: 144] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Accepted: 09/19/2018] [Indexed: 02/08/2023] Open
Abstract
Medical three-dimensional (3D) printing has expanded dramatically over the past three decades with growth in both facility adoption and the variety of medical applications. Consideration for each step required to create accurate 3D printed models from medical imaging data impacts patient care and management. In this paper, a writing group representing the Radiological Society of North America Special Interest Group on 3D Printing (SIG) provides recommendations that have been vetted and voted on by the SIG active membership. This body of work includes appropriate clinical use of anatomic models 3D printed for diagnostic use in the care of patients with specific medical conditions. The recommendations provide guidance for approaches and tools in medical 3D printing, from image acquisition, segmentation of the desired anatomy intended for 3D printing, creation of a 3D-printable model, and post-processing of 3D printed anatomic models for patient care.
Collapse
Affiliation(s)
- Leonid Chepelev
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Nicole Wake
- Center for Advanced Imaging Innovation and Research (CAI2R), Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, NY USA
- Sackler Institute of Graduate Biomedical Sciences, NYU School of Medicine, New York, NY USA
| | | | - Waleed Althobaity
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Ashish Gupta
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Elsa Arribas
- Department of Diagnostic Radiology, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX USA
| | - Lumarie Santiago
- Department of Diagnostic Radiology, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX USA
| | - David H Ballard
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis, MO USA
| | - Kenneth C Wang
- Baltimore VA Medical Center, University of Maryland Medical Center, Baltimore, MD USA
| | - William Weadock
- Department of Radiology and Frankel Cardiovascular Center, University of Michigan, Ann Arbor, MI USA
| | - Ciprian N Ionita
- Department of Neurosurgery, State University of New York Buffalo, Buffalo, NY USA
| | - Dimitrios Mitsouras
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | | | | | - Andy Christensen
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Peter Liacouras
- 3D Medical Applications Center, Walter Reed National Military Medical Center, Washington, DC, USA
| | - Frank J Rybicki
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Adnan Sheikh
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| |
Collapse
|
7
|
Karmonik C, Elias SN, Zhang JY, Diaz O, Klucznik RP, Grossman RG, Britz GW. Augmented Reality with Virtual Cerebral Aneurysms: A Feasibility Study. World Neurosurg 2018; 119:e617-e622. [DOI: 10.1016/j.wneu.2018.07.222] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Revised: 07/24/2018] [Accepted: 07/25/2018] [Indexed: 10/28/2022]
|
8
|
Delayed Posttreatment Residual Flow into Aneurysm After Flow Diverter Placement. World Neurosurg 2018; 116:205-208. [PMID: 29852305 DOI: 10.1016/j.wneu.2018.05.137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Revised: 05/18/2018] [Accepted: 05/18/2018] [Indexed: 11/24/2022]
Abstract
BACKGROUND Inflow into an aneurysm sac immediately following flow diverter (FD) treatment is an assumed cause of delayed aneurysmal rupture. The significance of delayed posttreatment residual flow occurring months after FD treatment is unknown. CASE DESCRIPTION A 76-year-old woman with a large intracranial aneurysm measuring 23.0 × 18.1 mm in the cavernous segment of the right internal carotid artery was treated with placement of a single FD (Pipeline Embolization Device, Covidien, Irvine, California, USA). Postprocedure digital subtraction angiography (DSA) demonstrated flow stagnation inside the aneurysm dome. The patient was discharged 9 days post procedure without new neurologic deficits. A 6-month follow-up DSA demonstrated delayed posttreatment residual flow into the aneurysm sac. Although she was scheduled for additional FD placement because of concern for aneurysmal rupture, the operation was not conducted due to an interim motor vehicle accident. Oral treatment with aspirin (100 mg/day) and clopidogrel (75 mg/day) was continued during her recovery. DSA performed 12 months post procedure showed that the aneurysm had completely thrombosed. CONCLUSIONS Our findings suggest that delayed post-treatment residual flow into an aneurysm may form part of the normal clinical course post FD placement and may not preclude eventual thrombosis of the aneurysm. Larger studies are needed to determine whether more frequent follow-up DSAs after FD placement are necessary and whether all patients exhibiting delayed post-treatment residual flow into an aneurysm require additional FD placement or if watchful waiting is a more suitable course.
Collapse
|