Arif S, Brady Z, Enchev Y, Peev N, Encheva E. Minimising radiation exposure to the surgeon in minimally invasive spine surgeries: A systematic review of 15 studies.
Orthop Traumatol Surg Res 2021;
107:102795. [PMID:
33333283 DOI:
10.1016/j.otsr.2020.102795]
[Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 09/22/2020] [Accepted: 09/29/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND
Intraoperative imaging in minimally invasive spinal surgeries is associated with significant radiation exposure to surgeons, which overtime can lead to serious health hazards including malignancy. In this study, the authors conducted a systematic review to evaluate the efficacy of navigation assisted fluoroscopy methods on radiation exposure to the surgeon in minimally invasive spine surgeries, percutaneous endoscopic lumbar discectomy/percutaneous endoscopic transforaminal discectomy versus minimally invasive spine transforaminal lumbar interbody fusion (PELD/PETD versus MIS-TLIF).
METHODS
A systematic literature search was conducted using PUBMED/MEDLINE on 20th July, 2020. Inclusion criteria were applied according to study design, surgical technique, spinal region, and language. Data extracted included lumbar segment, average operation time (min), fluoroscopic time (s), and radiation dose (μSV), efficacy of modified navigation versus conventional techniques; on reducing operation, fluoroscopy times and effective radiation dose.
RESULTS
Fifteen studies (ten prospectives, and five retrospectives) were included for quantitative analysis. PELD recorded a shorter operation time (by 126.3min, p<0.001) and fluoroscopic time (by 22.9s, p=0.3) than MIS-TLIF. The highest radiation dose/case (μSV) for both techniques were recorded at the surgeon's: finger, chest, neck and eye. The effective dose for MIS-TLIF was 30μSV higher than PELD. Modified navigation techniques recorded a shorter operation time (by 15.9min, p=0.3); fluoroscopy time (by 289.8s, p=0.3); effective radiation dose (by 169.5μSV, p=0.3) than conventional fluoroscopy methods.
DISCUSSION
This systematic literature review showed that although navigation assisted fluoroscopy techniques are superior to conventional methods in minimising radiation exposure, lack of statistical significance warrants future randomised controlled trials, to solidify their efficacy in reducing radiation related hazards.