Hendrickson NR, Haselhuhn JJ, Odland K, Sembrano JN, Martin CT, Jones KE, Polly DW. Sacropelvic Fixation with Porous Fusion/Fixation Screws: A Technical Note and Retrospective Review.
World Neurosurg 2024;
190:172-180. [PMID:
38878891 DOI:
10.1016/j.wneu.2024.06.046]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Accepted: 06/09/2024] [Indexed: 08/06/2024]
Abstract
OBJECTIVE
The goal of this study was to analyze our initial experience using a novel porous fusion/fixation screw (PFFS) for pelvic fixation and determine our rate of screw malposition requiring intraoperative repositioning.
METHODS
We reviewed 83 consecutive patients who underwent sacropelvic fixation with PFFS at our institution from June 1, 2022 to June 30, 2023 using intraoperative computed tomography-based computer-assisted navigation via an open posterior approach. Following PFFS insertion, intraoperative computed tomography scans were obtained to assess screw positioning. Demographic data were collected, and operative reports and patient images were reviewed to determine what implants were used and if any PFFS required repositioning.
RESULTS
Seventy-four patients (26M:48F) were included, and 57 (77.0%) had a prior sacroiliac joint or lumbar spine surgery. A stacked screw configuration was used in 62/74 cases (83.8%). A total of 235 PFFS were used and six (2.6%) were malpositioned. Of 88 cephalic screws placed in stacked configuration, 4 were malpositioned (4.5%) and 1/123 caudal screws were malpositioned (0.8%). One of 24 sacral-alar-iliac screws placed in a stand-alone configuration was malpositioned (4.2%). Malpositions included 4 medial, 1 lateral, and 1 inferior, and all were revised intraoperatively without major sequela.
CONCLUSIONS
Although PFFSs are larger than traditional sacropelvic fixation screws, stacked sacral-alar-iliac instrumentation can be done safely with computer-assisted navigation. We found a low malposition rate in our initial series of patients, the majority being the cephalad screw in a stacked configuration. This isn't surprising, as these are placed after the caudal screws, which reduces the available corridor size and increases the placement difficulty.
Collapse