1
|
Huber KL, Stino H, Schlegl T, Steiner I, Nagy G, Niederleithner M, Baumann B, Drexler W, Leitgeb RA, Schmidt-Erfurth U, Schmoll T, Pollreisz A. Microaneurysm detection using high-speed megahertz optical coherence tomography angiography in advanced diabetic retinopathy. Acta Ophthalmol 2024; 102:e687-e695. [PMID: 38126128 DOI: 10.1111/aos.16619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 11/29/2023] [Accepted: 12/08/2023] [Indexed: 12/23/2023]
Abstract
PURPOSE To compare detection rates of microaneurysms (MAs) on high-speed megahertz optical coherence tomography angiography (MHz-OCTA), fluorescein angiography (FA) and colour fundus photography (CF) in patients with diabetic retinopathy (DR). METHODS For this exploratory cross-sectional study, MHz-OCTA data were acquired with a swept-source OCT prototype (A-scan rate: 1.7 MHz), and FA and CF imaging was performed using Optos® California. MA count was manually evaluated on en face MHz-OCTA/FA/CF images within an extended ETDRS grid. Detectability of MAs visible on FA images was evaluated on corresponding MHz-OCTA and CF images. MA distribution and leakage were correlated with detectability on OCTA and CF imaging. RESULTS 47 eyes with severe DR (n = 12) and proliferative DR (n = 35) were included. MHz-OCTA and CF imaging detected on average 56% and 36% of MAs, respectively. MHz-OCTA detection rate was significantly higher than CF (p < 0.01). The combination of MHz-OCTA and CF leads to an increased detection rate of 70%. There was no statistically significant association between leakage and MA detectability on OCTA (p = 0.13). For CF, the odds of detecting leaking MAs were significantly lower than non-leaking MAs (p = 0.012). Using MHz-OCTA, detection of MAs outside the ETDRS grid was less likely than MAs located within the ETDRS grid (outer ring, p < 0.01; inner ring, p = 0.028). No statistically significant difference between rings was observed for CF measurements. CONCLUSIONS More MAs were detected on MHz-OCTA than on CF imaging. Detection rate was lower for MAs located outside the macular region with MHz-OCTA and for leaking MAs with CF imaging. Combining both non-invasive modalities can improve MA detection.
Collapse
Affiliation(s)
- Kim Lien Huber
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Heiko Stino
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Thomas Schlegl
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Irene Steiner
- Center for Medical Data Science, Institute of Medical Statistics, Medical University of Vienna, Vienna, Austria
| | - Gergely Nagy
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Michael Niederleithner
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Rainer A Leitgeb
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Ursula Schmidt-Erfurth
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Tilman Schmoll
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
- Carl Zeiss Meditec, Inc., Dublin, California, USA
| | - Andreas Pollreisz
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
2
|
Nouri H, Abtahi SH, Mazloumi M, Samadikhadem S, Arevalo JF, Ahmadieh H. Optical coherence tomography angiography in diabetic retinopathy: A major review. Surv Ophthalmol 2024; 69:558-574. [PMID: 38521424 DOI: 10.1016/j.survophthal.2024.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Revised: 02/29/2024] [Accepted: 03/11/2024] [Indexed: 03/25/2024]
Abstract
Diabetic retinopathy (DR) is characterized by retinal vasculopathy and is a leading cause of visual impairment. Optical coherence tomography angiography (OCTA) is an innovative imaging technology that can detect various pathologies and quantifiable changes in retinal microvasculature. We briefly describe its functional principles and advantages over fluorescein angiography and perform a comprehensive review on its clinical applications in the screening or management of people with prediabetes, diabetes without clinical retinopathy (NDR), nonproliferative DR (NPDR), proliferative DR (PDR), and diabetic macular edema (DME). OCTA reveals early microvascular alterations in prediabetic and NDR eyes, which may coexist with sub-clinical neuroretinal dysfunction. Its applications in NPDR include measuring ischemia, detecting retinal neovascularization, and timing of early treatment through predicting the risk of retinopathy worsening or development of DME. In PDR, OCTA helps characterize the flow within neovascular complexes and evaluate their progression or regression in response to treatment. In eyes with DME, OCTA perfusion parameters may be of predictive value regarding the visual and anatomical gains associated with treatment. We further discussed the limitations of OCTA and the benefits of its incorporation into an updated DR severity scale.
Collapse
Affiliation(s)
- Hosein Nouri
- Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran; School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Seyed-Hossein Abtahi
- Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran; Department of Ophthalmology, Labbafinejad Medical Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Mehdi Mazloumi
- Eye Research Center, Rasoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran
| | - Sanam Samadikhadem
- Department of Ophthalmology, Imam Hossein Medical Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - J Fernando Arevalo
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
| | - Hamid Ahmadieh
- Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
3
|
Waheed NK, Rosen RB, Jia Y, Munk MR, Huang D, Fawzi A, Chong V, Nguyen QD, Sepah Y, Pearce E. Optical coherence tomography angiography in diabetic retinopathy. Prog Retin Eye Res 2023; 97:101206. [PMID: 37499857 PMCID: PMC11268430 DOI: 10.1016/j.preteyeres.2023.101206] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 07/24/2023] [Accepted: 07/25/2023] [Indexed: 07/29/2023]
Abstract
There remain many unanswered questions on how to assess and treat the pathology and complications that arise from diabetic retinopathy (DR). Optical coherence tomography angiography (OCTA) is a novel and non-invasive three-dimensional imaging method that can visualize capillaries in all retinal layers. Numerous studies have confirmed that OCTA can identify early evidence of microvascular changes and provide quantitative assessment of the extent of diseases such as DR and its complications. A number of informative OCTA metrics could be used to assess DR in clinical trials, including measurements of the foveal avascular zone (FAZ; area, acircularity, 3D para-FAZ vessel density), vessel density, extrafoveal avascular zones, and neovascularization. Assessing patients with DR using a full-retinal slab OCTA image can limit segmentation errors and confounding factors such as those related to center-involved diabetic macular edema. Given emerging data suggesting the importance of the peripheral retinal vasculature in assessing and predicting DR progression, wide-field OCTA imaging should also be used. Finally, the use of automated methods and algorithms for OCTA image analysis, such as those that can distinguish between areas of true and false signals, reconstruct images, and produce quantitative metrics, such as FAZ area, will greatly improve the efficiency and standardization of results between studies. Most importantly, clinical trial protocols should account for the relatively high frequency of poor-quality data related to sub-optimal imaging conditions in DR and should incorporate time for assessing OCTA image quality and re-imaging patients where necessary.
Collapse
Affiliation(s)
- Nadia K Waheed
- New England Eye Center, Tufts University School of Medicine, Boston, MA, USA.
| | - Richard B Rosen
- New York Eye and Ear Infirmary of Mount Sinai, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Yali Jia
- School of Medicine, Casey Eye Institute, Oregon Health and Science University, Portland, OR, USA
| | - Marion R Munk
- Augenarzt-Praxisgemeinschaft Gutblick AG, Pfäffikon, Switzerland
| | - David Huang
- School of Medicine, Casey Eye Institute, Oregon Health and Science University, Portland, OR, USA
| | - Amani Fawzi
- Department of Ophthalmology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Victor Chong
- Institute of Ophthalmology, University College London, London, UK
| | - Quan Dong Nguyen
- Byers Eye Institute, Stanford University School of Medicine, Stanford, CA, USA
| | - Yasir Sepah
- Byers Eye Institute, Stanford University School of Medicine, Stanford, CA, USA
| | | |
Collapse
|
4
|
Mino T, Moriguchi Y, Tamura M, Matsumoto A, Kubota A, Akiba M, Hwang Y, Makita S, Yasuno Y, Enaida H, Fujimoto JG, Wang Z. Extended and adjustable field-of-view of variable interscan time analysis by ammonite-scanning swept-source optical coherence tomography angiography. BIOMEDICAL OPTICS EXPRESS 2023; 14:4112-4125. [PMID: 37799706 PMCID: PMC10549733 DOI: 10.1364/boe.491611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 07/01/2023] [Accepted: 07/01/2023] [Indexed: 10/07/2023]
Abstract
A novel scanning protocol, ammonite scan, is proposed for widefield optical coherence tomography angiography (OCTA) and relative retinal blood flow velocity imaging in the human retina using variable interscan time analysis (VISTA). A repeated circle scan using a 400 kHz swept-source was employed to achieve an interscan time of 1.28 ms. The center of the repeated circular scan continuously moved spirally towards the peripheral region, ensuring an extended and adjustable scan range while preserving the short interscan time. Image artifacts due to eye movement were eliminated via extra motion-correction processing using data redundancy. The relative blood flow velocity in superficial and deep plexus layers was calculated from the VISTA image, and their ratio was used to explore the microvascular flow parameter in the healthy human eye.
Collapse
Affiliation(s)
- Toshihiro Mino
- Topcon Advanced Biomedical Imaging Laboratory, Topcon Medical Systems, 111 Bauer Drive, Oakland, NJ 07436, USA
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Yoshikiyo Moriguchi
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Masato Tamura
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Akiko Matsumoto
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Atsushi Kubota
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Masahiro Akiba
- Research & Development Division, Topcon Corporation, 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
| | - Yunchan Hwang
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Shuichi Makita
- Computational Optics Group, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Yoshiaki Yasuno
- Computational Optics Group, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Hiroshi Enaida
- Department of Ophthalmology, Faculty of Medicine, Saga University, 5-1-1 Nabeshima, Saga 849-8501, Japan
| | - James G. Fujimoto
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Zhenguo Wang
- Topcon Advanced Biomedical Imaging Laboratory, Topcon Medical Systems, 111 Bauer Drive, Oakland, NJ 07436, USA
| |
Collapse
|