1
|
Kichou H, Bonnier F, Dancik Y, Bakar J, Michael-Jubeli R, Caritá AC, Perse X, Soucé M, Rapetti L, Tfayli A, Chourpa I, Munnier E. Strat-M® positioning for skin permeation studies: A comparative study including EpiSkin® RHE, and human skin. Int J Pharm 2023; 647:123488. [PMID: 37805151 DOI: 10.1016/j.ijpharm.2023.123488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 09/25/2023] [Accepted: 10/04/2023] [Indexed: 10/09/2023]
Abstract
In the development and optimization of dermatological products, In Vitro Permeation Testing (IVPT) is pivotal for controlled study of skin penetration. To enhance standardization and replicate human skin properties reconstructed human skin and synthetic membranes are explored as alternatives. Strat-M® is a membrane designed to mimic the multi-layered structure of human skin for IVPT. For instance, in Strat-M®, the steady-state fluxes (JSS) of resorcinol in formulations free of permeation enhancers were found to be 41 ± 5 µg/cm2·h for the aqueous solution, 42 ± 6 µg/cm2·h for the hydrogel, and 40 ± 6 µg/cm2·h for the oil-in-water emulsion. These results were closer to excised human skin (5 ± 3, 9 ± 2, 13 ± 6 µg/cm2·h) and surpassed the performance of EpiSkin® RHE (138 ± 5, 142 ± 6, and 162 ± 11 µg/cm2·h). While mass spectrometry and Raman microscopy demonstrated the qualitative molecular similarity of EpiSkin® RHE to human skin, it was the porous and hydrophobic polymer nature of Strat-M® that more faithfully reproduced the skin's diffusion-limiting barrier. Further validation through similarity factor analysis (∼80-85%) underscored Strat-M®'s significance as a reliable substitute for human skin, offering a promising approach to enhance realism and reproducibility in dermatological product development.
Collapse
Affiliation(s)
- Hichem Kichou
- Université de Tours, EA 6295 Nanomédicaments et Nanosondes, Faculté de Pharmacie, 31 Avenue Monge, 37200 Tours, France
| | - Franck Bonnier
- LVMH Recherche, 185 Av. de Verdun, 45800 Saint-Jean-de-Braye, France
| | - Yuri Dancik
- Certara UK Ltd., Simcyp Division, Level 2-Acero, 1 Concourse Way, Sheffield S1 2B1, UK
| | - Joudi Bakar
- Université Paris-Saclay, Faculté de Pharmacie, Lip(sys)(2) « Lipides, Systèmes Analytiques et Biologiques », 17 avenue des sciences, 91400 Orsay, France
| | - Rime Michael-Jubeli
- Université Paris-Saclay, Faculté de Pharmacie, Lip(sys)(2) « Lipides, Systèmes Analytiques et Biologiques », 17 avenue des sciences, 91400 Orsay, France
| | - Amanda C Caritá
- Université de Tours, EA 6295 Nanomédicaments et Nanosondes, Faculté de Pharmacie, 31 Avenue Monge, 37200 Tours, France
| | - Xavier Perse
- Université de Tours, EA 6295 Nanomédicaments et Nanosondes, Faculté de Pharmacie, 31 Avenue Monge, 37200 Tours, France
| | - Martin Soucé
- Université de Tours, EA 6295 Nanomédicaments et Nanosondes, Faculté de Pharmacie, 31 Avenue Monge, 37200 Tours, France
| | - Laetitia Rapetti
- Alphenyx, 430 avenue du Maréchal Lattre de Tassigny, 13009 Marseille, France
| | - Ali Tfayli
- Université Paris-Saclay, Faculté de Pharmacie, Lip(sys)(2) « Lipides, Systèmes Analytiques et Biologiques », 17 avenue des sciences, 91400 Orsay, France
| | - Igor Chourpa
- Université de Tours, EA 6295 Nanomédicaments et Nanosondes, Faculté de Pharmacie, 31 Avenue Monge, 37200 Tours, France
| | - Emilie Munnier
- Université de Tours, EA 6295 Nanomédicaments et Nanosondes, Faculté de Pharmacie, 31 Avenue Monge, 37200 Tours, France.
| |
Collapse
|
2
|
Khalid A, Shoaib Sarwar H, Sarfraz M, Farhan Sohail M, Jalil A, Bin Jardan YA, Arshad R, Tahir I, Ahmad Z. Formulation and characterization of thiolated chitosan/polyvinyl acetate based microneedle patch for transdermal delivery of dydrogesterone. Saudi Pharm J 2023; 31:669-677. [PMID: 37181138 PMCID: PMC10172616 DOI: 10.1016/j.jsps.2023.03.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 03/08/2023] [Indexed: 03/17/2023] Open
Abstract
Microneedle patches are promising transdermal drug delivery platforms with minimal invasiveness in a painless manner. Microneedle patch could be a promising alternate route for delivery of drugs having poor solubility and low bioavailability. This research work therefore, aimed to develop and characterize microneedle patch of thiolated chitosan (TCS) and polyvinyl acetate (PVA) for the systemic delivery of dydrogesterone (DYD). TCS-PVA-based microneedle patch was fabricated with 225 needles having a length of 575 µm with the sharp pointed end. Different ratios of TCS-PVA-based patch were employed to investigate the effects of mechanical tensile strength and percentage elongation. The scanning electron microscopy (SEM) revealed intact sharp-pointed needles. In vitro dissolution studies of microneedle patch (MN-P) were carried out by modified Franz-diffusion cell revealing the sustained release of DYD 81.45 ± 2.768 % at 48 hrs as compared to pure drug that showed 96.7 ± 1.75 % at 12 hrs. The transport of DYD (81%) across skin reaching the systemic circulation was evaluated through ex vivo permeation studies of MN-P. The skin penetration study through the parafilm M method showed good penetration with no deformation and breakage of needles along with no visible signs of skin irritation. Histological study of mice skins clearly showed the deeper penetration of needles into the skin. In summary, as-prepared MN-P show potential in developing an effective transdermal delivery system for DYD.
Collapse
|
3
|
Waters LJ, Quah XL. Predicting skin permeability using HuskinDB. Sci Data 2022; 9:584. [PMID: 36151144 PMCID: PMC9508232 DOI: 10.1038/s41597-022-01698-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 09/14/2022] [Indexed: 11/16/2022] Open
Abstract
A freely accessible database has recently been released that provides measurements available in the literature on human skin permeation data, known as the ‘Human Skin Database – HuskinDB’. Although this database is extremely useful for sourcing permeation data to help with toxicity and efficacy determination, it cannot be beneficial when wishing to consider unlisted, or novel compounds. This study undertakes analysis of the data from within HuskinDB to create a model that predicts permeation for any compound (within the range of properties used to create the model). Using permeability coefficient (Kp) data from within this resource, several models were established for Kp values for compounds of interest by varying the experimental parameters chosen and using standard physicochemical data. Multiple regression analysis facilitated creation of one particularly successful model to predict Kp through human skin based only on three chemical properties. The model transforms the dataset from simply a resource of information to a more beneficial model that can be used to replace permeation testing for a wide range of compounds.
Collapse
Affiliation(s)
- Laura J Waters
- School of Applied Sciences, University of Huddersfield, Queensgate, Huddersfield, HD1 3DH, UK.
| | - Xin Ling Quah
- School of Applied Sciences, University of Huddersfield, Queensgate, Huddersfield, HD1 3DH, UK
| |
Collapse
|
4
|
Zhang T, Peng X, Li F, Toufouki S, Yao S. Risk-focused investigation on ionic liquids against their applied background in transdermal delivery. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.118770] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
5
|
Fanse S, Bao Q, Zou Y, Wang Y, Burgess DJ. Effect of crosslinking on the physicochemical properties of polydimethylsiloxane-based levonorgestrel intrauterine systems. Int J Pharm 2021; 609:121192. [PMID: 34666142 DOI: 10.1016/j.ijpharm.2021.121192] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 10/03/2021] [Accepted: 10/10/2021] [Indexed: 11/29/2022]
Abstract
Polydimethylsiloxane (PDMS)-based levonorgestrel intrauterine systems (LNG-IUSs) such as Mirena® are long-acting drug-device combination products designed to release LNG for contraceptive purposes up to 6 years. LNG-IUSs consist of a hollow cylindrical drug-PDMS reservoir mounted with a polyethylene frame and covered by an outer PDMS membrane. PDMS is the release-controlling excipient present in both the matrix and the outer membrane. The degree of PDMS crosslinking is a key parameter in LNG-IUS manufacturing, dictating the elasticity and mechanical strength (which are critical parameters in molding and demolding of the cylindrical reservoirs). In addition, elasticity and mechanical strength are also important to prevent deformation during insertion into the uterine cavity. The objectives of this study were to investigate the impact of PDMS crosslinking on the physicochemical properties of LNG-IUSs and to develop appropriate testing methods for characterization of their mechanical strength. Formulations with different degrees of crosslinking were prepared by varying the ratio of the PDMS elastomer base and the crosslinking agent. A novel solvent swelling and extraction method was developed to determine the degree of PDMS crosslinking. The extent of crosslinking was also characterized via FTIR, Raman, 1H NMR, DSC, TGA and dynamic mechanical analysis. As expected, formulations with higher degrees of crosslinking showed lower crystallinity. Interestingly, the less crystalline formulations showed higher Tg values and storage moduli compared to the high crystalline formulations, implying that crosslinking is the predominant parameter governing the physicochemical and mechanical properties in LNG-IUSs. Correlations were established between PDMS crosslinking and the physicochemical properties of LNG-IUSs which will be useful for quality control purposes during formulation screening and development. A better understanding of the physicochemical characteristics of these complex products will facilitate drug product development.
Collapse
Affiliation(s)
- Suraj Fanse
- University of Connecticut, School of Pharmacy, Storrs, CT 06269, USA
| | - Quanying Bao
- University of Connecticut, School of Pharmacy, Storrs, CT 06269, USA
| | - Yuan Zou
- Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, FDA, Silver Spring, MD 20993, USA
| | - Yan Wang
- Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, FDA, Silver Spring, MD 20993, USA
| | - Diane J Burgess
- University of Connecticut, School of Pharmacy, Storrs, CT 06269, USA.
| |
Collapse
|
6
|
Mystkowska J, Powojska A, Łysik D, Niewęgłowska J, Bermúdez GSC, Mystkowski A, Makarov D. The Effect of Physiological Incubation on the Properties of Elastic Magnetic Composites for Soft Biomedical Sensors. SENSORS (BASEL, SWITZERLAND) 2021; 21:7122. [PMID: 34770427 PMCID: PMC8588498 DOI: 10.3390/s21217122] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 10/21/2021] [Accepted: 10/24/2021] [Indexed: 12/28/2022]
Abstract
Magnetic micro- and nanoparticles (MPs)-based composite materials are widely used in various applications in electronics, biotechnology, and medicine. This group of silicone composites have advantageous magnetic and mechanical properties as well as sufficient flexibility and biocompatibility. These composites can be applied in medicine for biological sensing, drug delivery, tissue engineering, and as remote-controlled microrobots operating in vivo. In this work, the properties of polydimethylsiloxane (PDMS)-based composites with different percentages (30 wt.%, 50 wt.%, 70 wt.%) of NdFeB microparticles as a filler were characterized. The novelty of the work was to determine the influence of the percentage of MP content and physiological conditioning on the properties of the PDMS-MP composites after in vitro incubation. An important essence of the work was a comprehensive study of the properties of materials important from the point of view of medical applications. Materials were tested before and after conditioning in 0.9 wt.% NaCl solution at a temperature of 37 °C. Several studies were carried out, including thermal, physicochemical, and rheological tests. The results show that with an increase of the incubation time, most of the measured thermal and physicochemical parameters decreased. The presence of the magnetic filler, especially at a concentration of 70 wt.%, has a positive effect on thermal stability and physicochemical and rheological properties. The performed tests provided important results, which can lead to further research for a broader application of magnetic composites in the biomedical field.
Collapse
Affiliation(s)
- Joanna Mystkowska
- Institute of Biomedical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland; (A.P.); (D.Ł.); (J.N.)
| | - Anna Powojska
- Institute of Biomedical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland; (A.P.); (D.Ł.); (J.N.)
| | - Dawid Łysik
- Institute of Biomedical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland; (A.P.); (D.Ł.); (J.N.)
| | - Joanna Niewęgłowska
- Institute of Biomedical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland; (A.P.); (D.Ł.); (J.N.)
| | - Gilbert Santiago Cañón Bermúdez
- Helmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328 Dresden, Germany; (G.S.C.B.); (D.M.)
| | - Arkadiusz Mystkowski
- Department of Automatic Control and Robotics, Faculty of Electrical Engineering, Bialystok University of Technology, Wiejska 45D, 15-351 Bialystok, Poland;
| | - Denys Makarov
- Helmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Bautzner Landstrasse 400, 01328 Dresden, Germany; (G.S.C.B.); (D.M.)
| |
Collapse
|