Wampl S, Körner T, Valkovič L, Trattnig S, Wolzt M, Meyerspeer M, Schmid AI. Investigating the effect of trigger delay on cardiac 31P MRS signals. Sci Rep 2021; 11:9268. [PMID: 33927234 PMCID: PMC8085231 DOI: 10.1038/s41598-021-87063-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Accepted: 03/22/2021] [Indexed: 01/15/2023] Open
Abstract
The heart’s geometry and its metabolic activity vary over the cardiac cycle. The effect of these fluctuations on phosphorus (31P) magnetic resonance spectroscopy (MRS) data quality and metabolite ratios was investigated. 12 healthy volunteers were measured using a 7 T MR scanner and a cardiac 31P-1H loop coil. 31P chemical shift imaging data were acquired untriggered and at four different times during the cardiac cycle using acoustic triggering. Signals of adenosine-triphosphate (ATP), phosphocreatine (PCr), inorganic phosphate (Pi) and 2,3-diphosphoglycerate (2,3-DPG) and their fit quality as Cramér-Rao lower bounds (CRLB) were quantified including corrections for contamination by 31P signals from blood, flip angle, saturation and total acquisition time. The myocardial filling factor was estimated from cine short axis views. The corrected signals of PCr and \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\gamma$$\end{document}γ-ATP were higher during end-systole and lower during diastasis than in untriggered acquisitions (\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$P<0.05$$\end{document}P<0.05). Signal intensities of untriggered scans were between those with triggering to end-systole and diastasis. Fit quality of PCr and \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\gamma$$\end{document}γ-ATP peaks was best during end-systole when blood contamination of ATP and Pi signals was lowest. While metabolite ratios and pH remained stable over the cardiac cycle, signal amplitudes correlated strongly with myocardial voxel filling. Triggering of cardiac 31P MRS acquisitions improves signal amplitudes and fit quality if the trigger delay is set to end-systole. We conclude that triggering to end-systole is superior to triggering to diastasis.
Collapse
Affiliation(s)
- Stefan Wampl
- Medical University of Vienna, High Field MR Center, Center for Medical Physics and Biomedical Engineering, Vienna, 1090, Austria
| | - Tito Körner
- Medical University of Vienna, High Field MR Center, Center for Medical Physics and Biomedical Engineering, Vienna, 1090, Austria
| | - Ladislav Valkovič
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), RDM Cardiovascular Medicine, University of Oxford, Oxford, OX3 9DU, United Kingdom.,Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, 814 04, Slovakia
| | - Siegfried Trattnig
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, High Field MR Center, Vienna, 1090, Austria
| | - Michael Wolzt
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, 1090, Austria
| | - Martin Meyerspeer
- Medical University of Vienna, High Field MR Center, Center for Medical Physics and Biomedical Engineering, Vienna, 1090, Austria
| | - Albrecht Ingo Schmid
- Medical University of Vienna, High Field MR Center, Center for Medical Physics and Biomedical Engineering, Vienna, 1090, Austria.
| |
Collapse
|