For: Grabsch EA, Grayson ML, Johnson PDR, Yates LA, Harper RW, Smolich JJ. Bactericidal efficacy of sterilizing protocol for reused cardiac electrophysiology catheters. Am J Cardiol 2002;89:770-2. [PMID: 11897224 DOI: 10.1016/s0002-9149(01)02353-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Number Cited by Other Article(s)
1
Conception and validation of a protocol for reuse of non-irrigated electrophysiology catheters in a Brazilian teaching hospital. J Interv Card Electrophysiol 2017;51:45-50. [DOI: 10.1007/s10840-017-0301-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2016] [Accepted: 11/29/2017] [Indexed: 10/18/2022]
2
Tessarolo F, Caola I, Caciagli P, Guarrera GM, Nollo G. Sterility and Microbiological Assessment of Reused Single-Use Cardiac Electrophysiology Catheters. Infect Control Hosp Epidemiol 2016;27:1385-92. [PMID: 17152039 DOI: 10.1086/508829] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2005] [Accepted: 09/22/2005] [Indexed: 11/04/2022]
3
Tessarolo F, Caola I, Fedel M, Stacchiotti A, Caciagli P, Guarrera GM, Motta A, Nollo G. Different experimental protocols for decontamination affect the cleaning of medical devices. A preliminary electron microscopy analysis. J Hosp Infect 2007;65:326-33. [PMID: 17241696 DOI: 10.1016/j.jhin.2006.10.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2005] [Accepted: 10/03/2006] [Indexed: 10/23/2022]
4
Druce JD, Russell JS, Birch CJ, Vickery K, Harper RW, Smolich JJ. Cleaning and sterilization protocol for reused cardiac electrophysiology catheters inactivates hepatitis and coxsackie viruses. Infect Control Hosp Epidemiol 2005;26:720-5. [PMID: 16156330 DOI: 10.1086/502609] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
5
Kumar RK, Tynan MJ. Catheter interventions for congenital heart disease in third world countries. Pediatr Cardiol 2005;26:241-9. [PMID: 16082576 DOI: 10.1007/s00246-005-1005-5] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
6
Druce JD, Russell JS, Birch CJ, Yates LA, Harper RW, Smolich JJ. A decontamination and sterilization protocol employed during reuse of cardiac electrophysiology catheters inactivates human immunodeficiency virus. Infect Control Hosp Epidemiol 2003;24:184-90. [PMID: 12683509 DOI: 10.1086/502190] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]