1
|
Management of No-Reflow. Microcirculation 2020. [DOI: 10.1007/978-3-030-28199-1_15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
2
|
Kumar J, O’Connor CT, Kumar R, Arnous SK, Kiernan TJ. Coronary no-reflow in the modern era: a review of advances in diagnostic techniques and contemporary management. Expert Rev Cardiovasc Ther 2019; 17:605-623. [DOI: 10.1080/14779072.2019.1653187] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Jathinder Kumar
- Department of Cardiology University Hospital Limerick, GEMS, University of Limerick, Limerick, Ireland
| | - Cormac T O’Connor
- Department of Cardiology University Hospital Limerick, GEMS, University of Limerick, Limerick, Ireland
| | - Rajesh Kumar
- Department of Cardiology University Hospital Limerick, GEMS, University of Limerick, Limerick, Ireland
| | - Samer Khalil Arnous
- Department of Cardiology University Hospital Limerick, GEMS, University of Limerick, Limerick, Ireland
| | - Thomas J. Kiernan
- Department of Cardiology University Hospital Limerick, GEMS, University of Limerick, Limerick, Ireland
| |
Collapse
|
3
|
Su Q, Li L, Liu YC, Zhou Y, Wen WM. Effect of metoprolol on myocardial apoptosis after coronary microembolization in rats. World J Emerg Med 2014; 4:138-43. [PMID: 25215108 PMCID: PMC4129839 DOI: 10.5847/wjem.j.issn.1920-8642.2013.02.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2013] [Accepted: 05/06/2013] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Coronary microembolization (CME) is a serious complication following percutaneous coronary intervention (PCI) in patients with acute coronary syndromes. The use of metoprolol before PCI can significantly protect ischemic myocardium from myocardial damage, but the function of metoprolol in the treatment of CME is not entirely clear. This study was to explore the effect and significance of metoprolol on myocardial apoptosis and caspase-3 activation after CME in rats. METHODS Thirty rats were randomly divided into three groups including sham-operation (control group), CME plus saline (CME group), CME plus metoprolol (metoprolol group), 10 rats for each group. The CME group was induced by injecting 3 000 polyethylene microspheres (42 μm) into the left ventricle during a 10-second occlusion of the ascending aorta; the control group was injected with physiological saline instead of microembolization ball; the metoprolol or saline group was given three intravenous bolus injections before CME. Echocardiography, TUNEL staining, and Western blotting were used to evaluate cardiac function, proportion of apoptotic cells and activation of caspase-3 respectively at 6 hours after operation. RESULTS Echocardiographic parameters displayed that the metoprolol group improved cardiac function significantly compared with the CME group (P<0.05). The myocardial apoptotic rate of the CME group as well as the contents of activated caspase-3 increased significantly (P<0.05), both of which were ameliorated significantly by metoprolol treatment (P<0.05). CONCLUSIONS This study demonstrates that metoprolol can protect the myocardium during CME in rats by inhibiting apoptosis and improving cardiac function. These results suggest that the inhibition of apoptosis can be a potential therapeutic strategy for the treatment of CME.
Collapse
Affiliation(s)
- Qiang Su
- Department of Cardiology, First Affiliated Hospital of Guangxi Medical University, Nanning 530021, China
| | - Lang Li
- Department of Cardiology, First Affiliated Hospital of Guangxi Medical University, Nanning 530021, China
| | - Yang-Chun Liu
- Department of Cardiology, First Affiliated Hospital of Guangxi Medical University, Nanning 530021, China
| | - You Zhou
- Department of Cardiology, First Affiliated Hospital of Guangxi Medical University, Nanning 530021, China
| | - Wei-Ming Wen
- Department of Cardiology, First Affiliated Hospital of Guangxi Medical University, Nanning 530021, China
| |
Collapse
|
4
|
Intracoronary microparticles and microvascular obstruction in patients with ST elevation myocardial infarction undergoing primary percutaneous intervention. Eur Heart J 2012; 33:2928-38. [DOI: 10.1093/eurheartj/ehs065] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
|
5
|
Li L, Su Q, Wang Y, Dai R, Lu Y, Su B, Zhao Y. Effect of atorvastatin (Lipitor) on myocardial apoptosis and caspase-8 activation following coronary microembolization. Cell Biochem Biophys 2012; 61:399-406. [PMID: 21556942 DOI: 10.1007/s12013-011-9199-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
We determined the effect of atorvastatin on myocardial apoptosis and caspase-8 activation following coronary microembolization (CME) in a rat model. For this, 50 rats were randomly and equally divided into CME; sham-operated (control); atorvastatin lavage; gastric lavage control; and caspase-8 inhibitor (CHO) groups. In CME animals, a microembolization ball was injected through the left ventricle. Sham animals were injected with normal saline (NS). Atorvastatin group received atorvastatin gastric lavage once-a-day, 1 week before surgery. Gastric lavage controls had similar lavage with NS. CHO group was i.p-injected (CHO: 10 mg/kg) 30 min before surgery. Cardiac indices in each group were determined by echocardiography 6-h postoperatively. TUNEL assay and western blot were used for myocardial apoptosis and expression of caspases-3/-8, respectively. Echocardiography data show that left ventricular ejection fraction (LVEF) in CME group was significantly decreased (P < 0.05) compared with sham controls. Besides, left ventricular fractional shortening (FS) and cardiac output (CO) were also decreased with an increase in left ventricular end-diastolic dimension (LVEDd). Atorvastatin and CHO animals had significantly improved (P < 0.05) cardiac function compared with CME group. Myocardial apoptosis and activation levels of caspases-3/-8 were significantly increased (P < 0.05) compared with sham; myocardial apoptosis and activation levels of caspases-3/-8 were significantly decreased (P < 0.05) in atorvastatin and CHO groups compared with CME group. In conclusion, atorvastatin pretreatment suppressed post-CME myocardial apoptosis and improved cardiac function through the blockade of a myocardial death receptor-mediated apoptotic pathway.
Collapse
Affiliation(s)
- Lang Li
- Department of Cardiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, China.
| | | | | | | | | | | | | |
Collapse
|
6
|
Lee MS, Park SJ, Kandzari DE, Kirtane AJ, Fearon WF, Brilakis ES, Vermeersch P, Kim YH, Waksman R, Mehilli J, Mauri L, Stone GW. Saphenous vein graft intervention. JACC Cardiovasc Interv 2011; 4:831-43. [PMID: 21851895 DOI: 10.1016/j.jcin.2011.05.014] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2011] [Revised: 04/21/2011] [Accepted: 05/14/2011] [Indexed: 12/29/2022]
Abstract
Saphenous vein grafts are commonly used conduits for surgical revascularization of coronary arteries but are associated with poor long-term patency rates. Percutaneous revascularization of saphenous vein grafts is associated with worse clinical outcomes including higher rates of in-stent restenosis, target vessel revascularization, myocardial infarction, and death compared with percutaneous coronary intervention of native coronary arteries. Use of embolic protection devices is a Class I indication according to the American College of Cardiology/American Heart Association guidelines to decrease the risk of distal embolization, no-reflow, and periprocedural myocardial infarction. Nonetheless, these devices are underused in clinical practice. Various pharmacological agents are available that may also reduce the risk of or mitigate the consequences of no-reflow. Covered stents do not decrease the rates of periprocedural myocardial infarction and restenosis. Most available evidence supports treatment with drug-eluting stents in this high-risk lesion subset to reduce angiographic and clinical restenosis, although large, randomized trials comparing drug-eluting stents and bare-metal stents are needed.
Collapse
Affiliation(s)
- Michael S Lee
- University of California-Los Angeles Medical Center, Los Angeles, California, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Porto I, Belloni F, Niccoli G, Larosa C, Leone AM, Burzotta F, Trani C, De Maria GL, Hamilton-Craig C, Crea F. Filter no-reflow during percutaneous coronary intervention of saphenous vein grafts: incidence, predictors and effect of the type of protection device. EUROINTERVENTION 2011; 7:955-61. [DOI: 10.4244/eijv7i8a151] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
8
|
Al-Lamee R, Ielasi A, Latib A, Godino C, Ferraro M, Arioli F, Mussardo M, Piraino D, Figini F, Carlino M, Montorfano M, Chieffo A, Colombo A. Clinical and angiographic outcomes after percutaneous recanalization of chronic total saphenous vein graft occlusion using modern techniques. Am J Cardiol 2010; 106:1721-7. [PMID: 21126616 DOI: 10.1016/j.amjcard.2010.08.013] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2010] [Revised: 08/03/2010] [Accepted: 08/11/2010] [Indexed: 12/29/2022]
Abstract
Poor long-term outcomes after percutaneous coronary intervention (PCI) in chronic total occlusion (CTO) of saphenous vein grafts (SVGs) have been reported. However, limited data are available evaluating the use of modern techniques in this group. The aim of the present study was to assess the efficacy and long-term outcomes of PCI in SVG CTO with the routine use of embolic protection devices and drug-eluting stents. A retrospective cohort analysis was conducted of all consecutive patients undergoing PCI to SVG CTO from May 2002 to July 2009 at 2 centers. The indication for PCI was the presence of angina or silent ischemia with evidence of inducible ischemia after functional testing in the territory supplied by the SVG, despite optimal medical therapy. We identified 34 patients with SVG CTO. Of the 34 patients, 23 (68%) underwent successful SVG recanalization with stent implantation. An embolic protection device was used in 78% and 95% of stents implanted were drug-eluting stents. No in-hospital major adverse cardiac events occurred in the successful PCI group; one myocardial infarction occurred in the unsuccessful group. At follow-up (median 18.0 months, interquartile range 10.4 to 48.3), 1 case of myocardial infarction had occurred in the successful group. The in-stent restenosis rate was 68% (n = 13), of which 77% were focal, with target vessel revascularization in 61%. In conclusion, despite the relatively low procedural success rates, the clinical outcomes after successful PCI to SVG CTO with modern techniques were favorable. The repeat revascularization rates were high; however, graft patency was achievable in most after reintervention.
Collapse
|
9
|
Siewiorek GM, Wholey MH, Finol EA. In vitro performance assessment of distal protection filters: pulsatile flow conditions. J Endovasc Ther 2010; 16:735-43. [PMID: 19995122 DOI: 10.1583/09-2874.1] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE To evaluate in vitro the capture efficiency of a distal protection filter (DPF) used during carotid artery stenting and examine the longitudinal vascular impedance in the presence of a DPF. METHODS Four approved DPFs (Spider RX, FilterWire EZ, RX Accunet, and FiberNet) were evaluated in a physiologically realistic in vitro setup. A pulsatile programmable piston pump circulated a blood analog at a time-varying flow rate representative of the human common carotid artery. A silicone carotid bifurcation having average human dimensions was used for the carotid flow model. Microspheres ranging from 40 to 900 microm were injected to simulate embolization. The longitudinal vascular impedance was calculated as the ratio of the time-varying pressure gradient across the DPF to the time-varying flow rate in the internal carotid artery. RESULTS RX Accunet had the highest capture efficiency (99.4%) and Spider RX the lowest (78.1%). Spider RX increased the longitudinal vascular impedance the least after deployment (+23%), while FilterWire EZ increased the longitudinal vascular impedance the least after particles were injected (+29%). FiberNet increased longitudinal vascular impedance the most (+84%). CONCLUSION This investigation, unique for examining the effects of physiologically realistic pulsatile flow on DPF performance, can aid in the development of future generations of novel DPFs.
Collapse
Affiliation(s)
- Gail M Siewiorek
- Biomedical Engineering Department, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213, USA
| | | | | |
Collapse
|
10
|
Attenuated Plaque Detected by Intravascular Ultrasound. JACC Cardiovasc Interv 2009; 2:65-72. [DOI: 10.1016/j.jcin.2008.08.022] [Citation(s) in RCA: 108] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2008] [Accepted: 08/30/2008] [Indexed: 12/13/2022]
|
11
|
Tahk SJ, Choi BJ, Choi SY, Yoon MH, Gwon HC, Hong GR, Kim YJ, Hur SH, Kim KB, Koo BK, Lee SH, Yoon J. Distal protection device protects microvascular integrity during primary percutaneous intervention in acute myocardial infarction: A prospective, randomized, multicenter trial. Int J Cardiol 2008; 123:162-8. [PMID: 17490759 DOI: 10.1016/j.ijcard.2007.03.124] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2006] [Revised: 03/08/2007] [Accepted: 03/30/2007] [Indexed: 12/31/2022]
Abstract
BACKGROUND Distal protection during primary angioplasty in acute myocardial infarction (AMI) is the subject of recent controversy. The present study was designed to determine whether the distal embolic protection preserves myocardial microvascular integrity and improves clinical outcomes in patients with AMI. METHODS A total of 116 AMI patients presenting within 12 h of onset of symptoms were enrolled at 7 angioplasty centers. They were randomly assigned to either primary angioplasty with distal protection group (DP; n=60) or angioplasty alone group (Controls; n=56). RESULTS After primary angioplasty, achievement of final Thrombolysis In Myocardial Infarction (TIMI) grade 3 and TIMI Myocardial Perfusion (TMP) grade 3 were more frequent in the DP group than in the control group [58/60 (96%) vs. 43/56 (81%), p=0.016; and 39/60 (65%) vs. 20/56 (38%), p=0.001, respectively]. After primary angioplasty, the baseline and hyperemic averaged peak velocities were significantly higher (23.2+/-11.5 vs. 18.0+/-6.9 cm/s, p=0.029; and 39.2+/-16.7 vs. 30.6+/-10.8 cm/s, p=0.014, respectively) and the baseline and hyperemic microvascular resistance indices were significantly lower (4.18+/-2.22 vs. 5.34+/-2.25 mm Hg cm(-1) s, p=0.036; and 2.38+/-1.39 vs. 3.11+/-1.32 mm Hg cm(-1) s, p=0.030, respectively) in the DP group. Patients in the DP group showed more favorable phasic coronary flow pattern in diastolic deceleration time (679+/-262 vs. 519+/-289 ms, p=0.035; and 751+/-246 vs. 616+/-269 ms, p=0.035, respectively). Major adverse cardiac events at 6 months occurred with similar frequency in both groups (8.7% vs. 11.1%, p=0.400). CONCLUSIONS Distal protection device effectively preserves microvascular integrity during primary angioplasty in AMI. Distal protection, however, did not improve clinical outcomes.
Collapse
Affiliation(s)
- Seung-Jea Tahk
- Department of Cardiology, Ajou University School of Medicine, San 5 Wonchun-dong, Yeongtong-gu, Suwon, 443-721, Republic of Korea.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Carter LI, Golzar JA, Cavendish JJ, Dixon SR. Embolic Protection of Saphenous Vein Graft Percutaneous Interventions. J Interv Cardiol 2007; 20:351-8. [PMID: 17880331 DOI: 10.1111/j.1540-8183.2007.00284.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
13
|
Chan RS, Duong MH, Kaplan AV. Percutaneous coronary intervention in two occluded arms of a saphenous 'Y'-graft: the importance of protecting both of your arms. Catheter Cardiovasc Interv 2007; 70:374-8. [PMID: 17421014 DOI: 10.1002/ccd.21132] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Percutaneous intervention in saphenous vein grafts (SVG) carries a higher risk of distal embolization than intervention in a native vessel, and use of a distal protection device has been shown to improve the outcomes in SVG interventions. We describe an intervention done in an unexpected 'Y' SVG which required dual distal protection with Filterwires placed in both limbs of the diseased graft and which was performed via a 6 Fr guide catheter.
Collapse
Affiliation(s)
- Roger S Chan
- Cardiac Catheterization Laboratories, Section of Cardiology, Dartmouth Medical School and Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756-0001, USA
| | | | | |
Collapse
|
14
|
Abstract
Atherosclerotic plaque rupture is the key event in the pathogenesis of acute coronary syndromes and it also occurs during coronary interventions. Atherosclerotic plaque rupture does not always result in complete thrombotic occlusion of the epicardial coronary artery with subsequent impending myocardial infarction, but may in milder forms result in the embolization of atherosclerotic and thrombotic debris into the coronary microcirculation. This review summarizes the present experimental pathophysiology of coronary microembolization in animal models of acute coronary syndromes and highlights the main consequences of coronary microembolization--reduced coronary reserve, microinfarction, inflammation and oxidative modification of contractile proteins, contractile dysfunction and perfusion-contraction mismatch.Furthermore, the review presents the available clinical evidence for coronary microembolization in patients and compares the clinical observations with observations in the experimental model.
Collapse
Affiliation(s)
- Andreas Skyschally
- Institut für Pathophysiologie, Zentrum für Innere Medizin, Universitätsklinikum Essen, Hufelandstr. 55, 45122, Essen, Germany,
| | | | | | | | | | | |
Collapse
|
15
|
Okura H, Taguchi H, Kubo T, Toda I, Yoshida K, Yoshiyama M, Yoshikawa J. Atherosclerotic Plaque With Ultrasonic Attenuation Affects Coronary Reflow and Infarct Size in Patients With Acute Coronary Syndrome An Intravascular Ultrasound Study. Circ J 2007; 71:648-53. [PMID: 17456986 DOI: 10.1253/circj.71.648] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND No reflow following percutaneous coronary intervention (PCI) is a major concern in patients with acute coronary syndrome (ACS) and it may be influenced by the preexisting plaque type. METHODS AND RESULTS To evaluate the impact of plaque characteristics on coronary reflow following PCI in patients with ACS, a total of 110 patients (89 acute myocardial infarction, 21 unstable angina) were assessed by intravascular ultrasound. Plaque type was categorized as either atherosclerotic plaque without ultrasonic attenuation (group 1) or atherosclerotic plaque with attenuation (group 2). External elastic membrane, plaque plus media, and lumen area were measured. Coronary flow was assessed by Thrombolysis in Myocardial Infarction (TIMI) grade and TIMI frame count. Although the final TIMI frame count was similar between the 2 groups, TIMI frame count immediately after the first balloon inflation was significantly higher in group 2 (p=0.03). Despite the similar final TIMI grade and TIMI frame count, peak creatine kinase level was significantly higher (3,035+/-2,553 vs 1,950+/-1,958 IU/L, p=0.04) and fatal arrhythmia more frequently observed (16.4% vs 2.7%, p=0.04) in group 2 than in group 1. CONCLUSIONS Atherosclerotic plaque with ultrasonic attenuation may be related to a transient deterioration in coronary flow and as a result larger infarct size and higher incidence of fatal arrhythmia following PCI in patients with ACS. These results may help in selecting lesions suitable for distal protection devices.
Collapse
Affiliation(s)
- Hiroyuki Okura
- Division of Cardiology, Bell Land General Hospital, Sakai, Japan.
| | | | | | | | | | | | | |
Collapse
|
16
|
Abstract
Re-do coronary artery bypass graft (CABG) surgery carries significant risk to the patient and existing patent internal thoracic artery grafts. Stenting stenotic saphenous vein grafts (SVGs) with drug-eluting stents (DES) using embolic protection devices (EPDs) is therefore probably the optimum treatment. However, this is fraught with challenges such as distal embolisation and restenosis which may result in peri-procedural myocardial infarction and target vessel failure, respectively. This review focuses on the nature of SVG disease, percutaneous intervention utilising embolic protection and future directions aimed at combating the disappointingly high procedural complication rate and long-term recurrence in this group.
Collapse
Affiliation(s)
- Martin Hiscock
- Epworth Hospital, Richmond, Melbourne, Victoria 3121, Australia.
| | | | | |
Collapse
|
17
|
Abstract
Saphenous vein grafts (SVGs) are widely used as aortocoronary conduits during coronary artery bypass surgery and are critical in the high early success of coronary bypass revascularization. Saphenous vein grafts tend to be more prone than native coronary arteries to accelerated atherosclerosis and intimal fibrosis and thus frequently lead to recurrent symptoms and require further revascularization. Percutaneous coronary interventions (PCI) have become the prime means of SVG mechanical revascularization but are plagued by higher complication rates than PCI on native coronaries, largely due to embolic debris mobilized from around the target lesion in the SVG. Several mechanical devices and techniques have been developed to capture this friable material during the PCI before it can embolize; these devices have shown great promise in reducing the morbidity and mortality of these interventions and should be employed routinely.
Collapse
Affiliation(s)
- David T Cragun
- Division of Cardiology, University of Arizona, Phoenix, Arizona, USA
| | | |
Collapse
|
18
|
Abstract
Interventional cardiology has revolutionized modern cardiovascular care not only with the introduction of new approaches to the treatment of coronary artery disease, but also with the development of new invasive approaches to electrophysiologic procedures and the treatment of noncoronary vascular beds. This revolution continues to gather speed. Creative solutions continue to be proposed, evaluated, and then brought to the patient care arena. Issues remain, but these identify opportunities for continuing improvement.
Collapse
|
19
|
Leineweber K, Böse D, Vogelsang M, Haude M, Erbel R, Heusch G. Intense Vasoconstriction in Response to Aspirate From Stented Saphenous Vein Aortocoronary Bypass Grafts. J Am Coll Cardiol 2006; 47:981-6. [PMID: 16516081 DOI: 10.1016/j.jacc.2005.10.053] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2005] [Revised: 09/29/2005] [Accepted: 10/10/2005] [Indexed: 11/23/2022]
Abstract
OBJECTIVES We sought to identify soluble vasoconstrictor substances that are released during stent implantation into saphenous vein aortocoronary bypass grafts. BACKGROUND Atherosclerotic saphenous vein aortocoronary bypass grafts are particularly vulnerable to plaque rupture. Protection devices prevent particulate debris from being embolized. Additional soluble vasoconstrictor substances possibly also contribute to impaired microvascular perfusion. METHODS Peripheral venous blood (VB) and aspirate (AS) were obtained from 14 patients with a significant stenosis in a saphenous vein graft during stent implantation under protection with a distal balloon occlusion device. In five additional patients, arterial blood (AB) was also taken distal to the stented lesion before intervention. Vasomotor substances in VB, AB, and AS plasma were identified in a bioassay of rat mesenteric arteries with intact (+E) and denuded endothelium (-E). Vasoconstriction was normalized to that induced by potassium chloride depolarization (100%). RESULTS Venous blood, AB, and AS plasma induced maximum vasoconstriction within six minutes. The AS plasma induced a vasoconstriction of 138 +/- 13% (-E) and 87 +/- 14% (+E); VB, of 70 +/- 14% (-E) and 23 +/- 4% (+E); and AB plasma obtained before intervention, of 49 +/- 9% (-E) and 36 +/- 8% (+E). The vasoconstrictor potency of AS plasma in endothelium-denuded vessels was related to the severity of anginal symptoms, angiographic stenosis severity, plaque volume, and plaque burden as determined by intravascular ultrasound. The AS plasma-induced vasoconstriction was largely attenuated by combined serotonin/5-hydroxytryptamine (5-HT)(2A/2C)- and 5-HT(1A/1B)-receptor blockade and eliminated by additional thromboxane A2 thromboxane-prostanoid (TP)-receptor blockade. CONCLUSIONS Stent implantation releases, apart from and in addition to particulate debris, soluble vasoconstrictor substances that possibly contribute to impaired microvascular perfusion.
Collapse
Affiliation(s)
- Kirsten Leineweber
- Institute of Pathophysiology, University of Essen School of Medicine, Essen, Germany
| | | | | | | | | | | |
Collapse
|
20
|
Shaia N, Heuser RR. Distal Embolic Protection for SVG Interventions: Can We Afford Not to Use It? J Interv Cardiol 2005; 18:481-4. [PMID: 16336429 DOI: 10.1111/j.1540-8183.2005.00089.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
The development of atherosclerosis in saphenous vein grafts (SVGs) is one of the limiting factors in coronary artery bypass surgery. Approximately one half of vein conduits are significantly diseased or occluded at 10 years. A surgical revascularization strategy is often not pursued secondary to the incremental risks associated with a repeat bypass procedure. For this reason, percutaneous treatment of SVG disease is often the first option for a majority of patients. However, catheter-based treatment of SVG disease is associated with increased morbidity and mortality compared with native coronary arterial percutaneous intervention. This is often the result of distal embolization of atherothrombotic disease, leading to the phenomenon of "no-reflow." Intraprocedural pharmacological therapy has historically been the mainstay of treatment for these patients. However, more recently, the development of a mechanical embolic protection device has shown to be beneficial for the prevention of these complications. This article will review the types of embolic protection devices and the clinical studies that have proven their necessity in percutaneous SVG intervention.
Collapse
|
21
|
Dixon SR, Mann JT, Lauer MA, Casale PN, Dippel EJ, Strumpf RK, Feldman RL, Shear W, Resar JR, Zimmer SD, O'Neill WW. A randomized, controlled trial of saphenous vein graft intervention with a filter-based distal embolic protection device: TRAP trial. J Interv Cardiol 2005; 18:233-41. [PMID: 16115151 DOI: 10.1111/j.1540-8183.2005.00039.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
The purpose of this prospective, multicenter trial was to evaluate the safety and effectiveness of the TRAP Vascular Filtration System (VFS) to reduce embolic complications during stenting of diseased saphenous vein grafts (SVGs). Patients with SVG lesions were randomly assigned to undergo stenting with or without the TRAP device. The trial was designed to enroll 752 randomized patients. However, the sponsor terminated the study after a total of 467 patients (358 randomized) were enrolled because of poor recruitment once another distal protection device was approved for clinical use. The primary study endpoint, major adverse cardiac events at 30 days, occurred in 17.3% of control patients and 12.7% of patients treated with the TRAP device (P = 0.24). There was a trend toward a lower incidence of myocardial infarction in the TRAP group compared with the control group (16.2% vs 10.5%, P = 0.12). This difference was predominantly due to a lower incidence of moderate-large infarction (CKMB >5x) in the TRAP group. Use of the TRAP VFS during SVG intervention was safe and was associated with a trend toward a lower incidence of adverse events, however, due to low enrollment the study lacked sufficient power to detect a significant benefit with the device.
Collapse
Affiliation(s)
- Simon R Dixon
- William Beaumont Hospital, Royal Oak, MI 48073, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Dudek D, Mielecki W, Dziewierz A, Legutko J, Dubiel JS. The role of thrombectomy and embolic protection devices. Eur Heart J Suppl 2005. [DOI: 10.1093/eurheartj/sui063] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
23
|
Gorog DA, Foale RA, Malik I. Distal Myocardial Protection During Percutaneous Coronary Intervention. J Am Coll Cardiol 2005; 46:1434-45. [PMID: 16226166 DOI: 10.1016/j.jacc.2005.04.061] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2005] [Revised: 04/12/2005] [Accepted: 04/15/2005] [Indexed: 11/22/2022]
Abstract
The discrepancy between angiographic success and microvascular perfusion has been recognized for some time. In the face of an open artery, the degree of microvascular perfusion determines post-infarct prognosis. Despite successful epicardial recanalization, tissue perfusion may be absent in up to 25% patients with acute myocardial infarction. Historically associated with saphenous vein graft intervention, embolization is increasingly recognized in native coronary arteries, particularly in patients undergoing primary percutaneous coronary intervention (PCI). With more than two million PCI procedures performed worldwide each year, there is enormous interest in protecting the left ventricular myocardium from embolization during PCI. This article reviews the evidence for distal myocardial protection and discusses the relative merits of the different available techniques.
Collapse
Affiliation(s)
- Diana A Gorog
- Waller Cardiac Department, St. Mary's Hospital, London, United Kingdom.
| | | | | |
Collapse
|
24
|
Mizote I, Ueda Y, Ohtani T, Shimizu M, Takeda Y, Oka T, Tsujimoto M, Hirayama A, Hori M, Kodama K. Distal Protection Improved Reperfusion and Reduced Left Ventricular Dysfunction in Patients With Acute Myocardial Infarction Who Had Angioscopically Defined Ruptured Plaque. Circulation 2005; 112:1001-7. [PMID: 16103254 DOI: 10.1161/circulationaha.104.532820] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background—
Distal protection, in the Saphenous Vein Graft Angioplasty Free of Emboli (SAFER) trial, is demonstrated to prevent distal embolism in the percutaneous coronary intervention of saphenous vein graft. However, in the Enhanced Myocardial Efficacy and Recovery by Aspiration of Liberated Debris (EMERALD) trial, it was not effective in the percutaneous coronary intervention of native coronary arteries in patients with acute myocardial infarction (AMI). We hypothesized that its effectiveness would be determined by lesion characteristics. Therefore, we classified the type of culprit lesion by angioscopy and examined its influence on the effectiveness of distal protection, comparing patients with AMI treated with and without distal protection.
Methods and Results—
Consecutive patients with AMI treated without distal protection (n=110) from July 2000 to July 2002 and those treated with distal protection (n=81) from July 2002 to July 2004 were included. Patients in each group were subdivided according to whether or not they had angioscopically defined ruptured plaque at culprit lesion. Among those groups, incidence of no-reflow phenomenon, ST-segment resolution, myocardial blush grade, and left ventricular ejection fraction at 6 months were compared. Aspirated samples by distal protection were semiquantitatively and histologically analyzed and compared between patients with and without ruptured plaque. No-reflow phenomenon was most frequently (
P
<0.05) observed in patients with ruptured plaque treated without distal protection. ST-segment resolution (68±15% versus 40±21%,
P
<0.001), myocardial blush grade (2.6±0.5 versus 1.8±0.3,
P
<0.001), and left ventricular ejection fraction (47.2±6.7% versus 41.0±9.7%,
P
<0.01) were improved by distal protection among patients with ruptured plaque but not among patients without ruptured plaque. Aspirated samples >1 mm were detected more frequently (97.3% versus 78.5%,
P
<0.05) in patients with ruptured plaque than those without ruptured plaque. Histologically, aspirated samples contained plaque debris (95.3% versus 31.1%,
P
<0.05) more frequently in patients with ruptured plaque than in those without ruptured plaque.
Conclusions—
Distal protection reduced microcirculation damage and left ventricular dysfunction in patients with AMI who had angioscopically defined ruptured plaque. Distal embolization of plaque debris was detected more frequently in patients with ruptured plaque. These results suggest that microcirculation damage and left ventricular dysfunction are increased mainly by distal embolization of plaque debris rather than of thrombus.
Collapse
Affiliation(s)
- Isamu Mizote
- Cardiovascular Division, Osaka Police Hospital, Osaka, 543-0035, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Swaminathan A, Stone GW, Rogers C, Hermiller J, Feldman R, Hall P, Haber R, Masud ARZ, Cambier P, Caputo RP, Cox DA, Mehran R, Herrmann HC. Influence of vessel diameter on the efficacy of distal protection devices during saphenous vein graft intervention. Am J Cardiol 2005; 95:651-4. [PMID: 15721112 DOI: 10.1016/j.amjcard.2004.10.044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2004] [Revised: 10/22/2004] [Accepted: 10/22/2004] [Indexed: 10/25/2022]
Abstract
We sought to determine the influence of vessel diameter on the efficacy of distal protection devices during saphenous vein graft intervention. From the Filterwire EX Randomized Evaluation trial, in which patients who underwent saphenous vein graft stenting were randomized to distal protection with the GuardWire or FilterWire EX, outcomes in 572 patients were examined in vessel size tertiles. The 30-day composite incidence of major adverse cardiac events (MACEs) increased with vessel size and was 6.9%, 9.7%, and 14.9% in the smallest, middle, and largest tertiles, respectively (p = 0.04). MACE rates were relatively vessel size independent for the GuardWire but increased steadily with vessel size with the FilterWire EX. In the smallest tertile, MACEs were reduced by 71% with the FilterWire EX compared with the GuardWire (p = 0.05), with the devices showing similar event rates in the other tertiles.
Collapse
|
26
|
Iijima R, Tsunoda T, Yamamoto M, Shiba M, Wada M, Tsuji T, Yamamoto M, Nakajima R, Yoshitama T, Hara H, Hara H, Nakamura M. Fate of unprotected side branches as related to embolic complications during stent implantation for acute coronary syndromes using a distal protection procedure. Am J Cardiol 2005; 95:636-9. [PMID: 15721108 DOI: 10.1016/j.amjcard.2004.10.040] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2004] [Revised: 10/26/2004] [Accepted: 10/26/2004] [Indexed: 10/25/2022]
Abstract
Coronary lesion stenting with aspiration and distal balloon occlusion is more often associated with embolic occlusion of interposed side branches when the branch arises at an angle of </=45 degrees and the artery containing the lesion is large. However, this event is infrequent, often resolving during the procedure and uniformly resolving by 6 months.
Collapse
Affiliation(s)
- Raisuke Iijima
- Division of Cardiovascular Medicine, Ohashi Hospital, Toho University School of Medicine, Tokyo, Japan.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Laarman GJ, Kiemeneij F, Mueller R, Guagliumi G, Cobaugh M, Serruys PW. Feasibility, safety, and preliminary efficacy of a novel ePTFE-covered self-expanding stent in saphenous vein graft lesions: The Symbiot II trial. Catheter Cardiovasc Interv 2005; 64:361-8. [PMID: 15736242 DOI: 10.1002/ccd.20282] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Compared with percutaneous interventions in native coronary arteries, revascularization of saphenous vein graft (SVG) lesions is associated with increased rates of immediate and long-term major adverse cardiac events (MACE). The Symbiot II trial was a multicenter prospective study designed to evaluate the feasibility and safety of a novel self-expanding polytetrafluoroethylene (ePTFE)-covered stent in the treatment of de novo and restenotic SVG lesions. The primary endpoint was MACE through 30 days postprocedure. Successful Symbiot stent deployment was achieved in 75 of 77 patients (97.4%) with SVG lesions < or = 35 mm in length (visual assessment). The procedural success rate (defined as < 30% residual stenosis at the target site and no clinical complications) was 83%, and all study device procedures provided grade 3 TIMI flow postprocedure. Within the first 30 days postprocedure, four patients (5.2%) experienced MACE (defined as death, Q-wave or non-Q-wave myocardial infarction, and clinically driven target vessel revascularization), of whom three patients (3.9%) experienced periprocedural non-Q-wave myocardial infarction. No subacute stent thrombosis was observed over the 6-month follow-up period. No relevant luminal loss at the target site (mean, 0.3 +/- 0.9 mm) was observed in the 58 patients (77.3% of enrolled patients) who underwent quantitative coronary angiography at 6 months. The incidences of binary in-stent restenosis, in-segment restenosis, and target vessel failure (defined as acute and late-term MACE through 6 months postprocedure) were low (7.0%, 8.6%, and 14.3%, respectively). The Symbiot self-expanding ePTFE membrane-covered stent was associated with a high procedural success rate (97.4%), low incidences of MACE at 30 days (5.2%) and 6 months (14.3%), suggesting that it is safe and effective in the treatment of SVG disease.
Collapse
Affiliation(s)
- Gerrit J Laarman
- Amsterdam Department of Interventional Cardiology, OLVG, Amsterdam, The Netherlands.
| | | | | | | | | | | |
Collapse
|
28
|
Amor M, Eid-Lidt G, Chati Z, Wilentz JR. Endovascular treatment of the subclavian artery: Stent implantation with or without predilatation. Catheter Cardiovasc Interv 2004; 63:364-70. [PMID: 15505851 DOI: 10.1002/ccd.20173] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The endovascular treatment of subclavian artery (SA) lesions is less invasive than open surgical repair, with a low rate of complications. We report our experience in 89 subclavian obstructive lesions (n = 86) treated with stenting: 76 (85.3%) stenoses and 13 (14.6%) total occlusions. The left side was most frequently involved (83.1%), localized at the prevertebral segment in 91%. Technical success was obtained in 83 (93.3%) cases, 100% in stenotic lesions and 53.8% in total occlusions. There were nine global complications (10.1%): five (5.6%) at site of puncture, two distal embolization (2.2%), and two (2.3%) major events. The long-term follow-up was 3.51 +/- 1.98 years, during which time 13 (16.8%) restenoses and 2 (2.6%) reocclusions were noted. Subgroup analysis of patients with stenting after predilatation versus direct stenting technique showed in-hospital complications only in the first group, with a restenosis rate of 28.5% vs. 4.7%, respectively (P = 0.003). We consider stenting for SA obstructive lesions the first therapeutic option.
Collapse
Affiliation(s)
- Max Amor
- Section of Interventional Cardiology, Polyclinique Louis Pasteur, Essey-les-Nancy, France
| | | | | | | |
Collapse
|
29
|
Sievert H, Wahr DW, Schuler G, Schofer JJ, Sutsch G, Pavliska J, Skowasch M. Effectiveness and safety of the Proxis system in demonstrating retrograde coronary blood flow during proximal occlusion and in capturing embolic material. Am J Cardiol 2004; 94:1134-9. [PMID: 15518607 DOI: 10.1016/j.amjcard.2004.07.079] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2004] [Revised: 07/14/2004] [Accepted: 07/14/2004] [Indexed: 11/21/2022]
Abstract
The Feasibility And Safety Trial for its embolic protection device during transluminal intervention in coronary vessels: a European Registry (FASTER) was designed to demonstrate that (1) the Proxis embolic protection system can control anterograde flow and reverse blood flow in native coronary arteries and saphenous vein grafts; and (2) this system can capture embolic debris. Percutaneous coronary intervention on stenotic coronary lesions revolutionized treatment of coronary disease, but is associated with the risk of major adverse cardiac events. This prospective, nonrandomized, multicenter clinical feasibility and safety study enrolled 40 patients with 51 lesions at 4 centers who underwent treatment of stenotic lesions with proximal emboli protection (Proxis system). Proxis was successfully used 95% of the time, and embolic debris was qualitatively identified in all cases. Major adverse cardiac events occurred in 2 patients (5.0%): 1 late in-stent thrombosis resulting in death and 1 non-Q-wave infarction when a lesion was crossed before deployment of the Proxis system. Mean vessel occlusion time was 4.3 +/- 2.4 minutes. Native flow reversal was sufficient in 31 patients, with a mean aspirate volume of 11.8 +/- 6.5 ml. When the infusion catheter was used to augment reflow, mean occlusion time was 4.6 minutes. In conclusion, this trial is the first to demonstrate that retrograde blood flow can be achieved during proximal occlusion and that the Proxis system can be used safely during intervention of saphenous vein grafts and native coronary arterial lesions to capture embolic material.
Collapse
Affiliation(s)
- Horst Sievert
- CardioVascuLar Center Frankfurt, Sankt Katharinen, Frankfurt, Germany
| | | | | | | | | | | | | |
Collapse
|
30
|
Angelini A, Rubartelli P, Mistrorigo F, Della Barbera M, Abbadessa F, Vischi M, Thiene G, Chierchia S. Distal protection with a filter device during coronary stenting in patients with stable and unstable angina. Circulation 2004; 110:515-21. [PMID: 15277328 DOI: 10.1161/01.cir.0000137821.94074.ee] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Filter protection after percutaneous coronary intervention (PCI) is now available to prevent distal embolization. The aims of this study were (1) to evaluate the microembolization phenomenon during procedures of stent implantation in native coronary arteries of patients with stable and unstable angina, (2) to assess the amount and characteristics of the debris captured by the Angioguard, and (3) to investigate the relation between clinical and angiographic variables and pathological data. METHODS AND RESULTS Elective coronary stenting with the use of a protective filter was attempted in 39 consecutive coronary artery lesions with >60% stenosis (mean, 67.6+/-8.79%). Debris was present in 75.6% of the filters. Particle size ranged from 47.16 to 2503.48 microm (mean, 518.83+/-319.61 microm) in the major axis. Particles >300 microm were found in 24 of 28 filters with debris (85.7%), and particles >1000 microm were present in 10 of 28 filters (35.7%). Patients with unstable angina had greater particles (mean maximum longitudinal diameter, 1098.33+/-714.3 microm) than those with stable angina (412.91+/-453 microm; P<0.001). The presence of unstable angina (OR, 65; CI, 1.2 to 3420; P=0.03) and age >67 years (OR, 42; CI, 1 to 1698; P=0.04) were found to be the only independent predictors of embolic particle size. CONCLUSIONS By limiting embolization, protective devices may prevent a number of potentially unfavorable events, thereby improving outcome. Our data support the use of these devices, especially in lesions with higher embolic potential, such as those occurring in older patients and in those with unstable angina.
Collapse
Affiliation(s)
- Annalisa Angelini
- Department of Pathology, University of Padua Medical School, Via A. Gabelli, 61, 35121 Padua, Italy
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Cicek D, Doven O, Pekdemir H, Camsari A, Akkus NM, Cin GV, Parmaksiz T, Katircibasi T. Procedural results and distal embolization after saphenous vein graft stenting and angioplasty for in-stent restenosis of grafts. JAPANESE HEART JOURNAL 2004; 45:561-71. [PMID: 15353867 DOI: 10.1536/jhj.45.561] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
Abstract
Saphenous vein graft (SVG) angioplasty is associated with frequent periprocedural complications due to distal embolization and a high risk of restenosis. The purpose of this single-center, retrospective study was to determine the distal embolization incidences and outcomes of stenting for SVG lesions and percutaneous angioplasty for in-stent restenosis of these SVGs. We studied 48 consecutive patients (mean age, 62 +/- 7 years, 92% men) who had prior CABG and underwent stent deployment to SVG lesions detected at our institution over a period of 4 years. Mean lesion length was 12.4 +/- 3.2 mm. The minimal lumen diameter increased from 0.7 +/- 0.3 mm to 3.2 +/- 0.4 mm after stenting. Distal embolization as no reflow/slow flow phenomenon occurred in 5 (10%) patients. Angiographic success was achieved in 98% of the patients. Procedural success was achieved in 96% of the patients. No reflow/slow flow phenomenon was observed, particularly in patients with acute coronary syndrome. During the follow-up, 11 patients (23%) had angiographic evidence of restenosis. Lesions were treated with balloon angioplasty and the minimal lumen diameter increased from 2.6 +/- 1.1 mm to 3.1 +/- 0.3 mm. The angiographic and procedural success rates were both 100%. There were no cases of "no" reflow/slow flow. Restenosis was particularly frequent in patients with diabetes mellitus, hypercholesterolemia, and acute coronary syndrome. Stent implantation in patients with de novo SVG lesions can be achieved with a high rate of angiographic and procedural success. The distal embolization risk is lower during angioplasty of in-stent restenosis lesions of SVGs compared to de novo SVG lesions.
Collapse
Affiliation(s)
- Dilek Cicek
- Cardiology Department, Medical Faculty, Mersin University, Turkey
| | | | | | | | | | | | | | | |
Collapse
|
32
|
Costa MA, Gigliotti OS, Zenni MM, Gilmore PS, Bass TA. Synergistic use of sirolimus-eluting stents and intravascular ultrasound for the treatment of unprotected left main and vein graft disease. Catheter Cardiovasc Interv 2004; 61:368-75. [PMID: 14988898 DOI: 10.1002/ccd.10782] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Treating unprotected left main disease and degenerated saphenous vein grafts by percutaneous intervention remains one of the more challenging situations facing interventional cardiologists. We present two cases showing how the use of sirolimus-eluting stents in combination with other novel techniques might alter treatment paradigms in the future.
Collapse
Affiliation(s)
- Marco A Costa
- Division of Cardiology, Shands Hospital, University of Florida Health Science Center, Jacksonville, Florida 32209, USA
| | | | | | | | | |
Collapse
|
33
|
Rogers C, Huynh R, Seifert PA, Chevalier B, Schofer J, Edelman ER, Toegel G, Kuchela A, Woupio A, Kuntz RE, Macon ND. Embolic Protection With Filtering or Occlusion Balloons During Saphenous Vein Graft Stenting Retrieves Identical Volumes and Sizes of Particulate Debris. Circulation 2004; 109:1735-40. [PMID: 15066954 DOI: 10.1161/01.cir.0000124724.14491.6f] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background—
Distal embolization of plaque particulate liberated during stenting may cause periprocedural complications. The number, size, and volume of debris released during stenting, however, have not been quantified, rendering embolic protection approaches empiric. We used a novel method of microparticle size assessment to measure volume and characterize individual sizes of particles captured by the PercuSurge GuardWire balloon or a vascular filter during saphenous vein graft stenting.
Methods and Results—
Braided nitinol filters (average distal pore size 100 μm) were used in 47 saphenous vein grafts in 44 patients. The PercuSurge GuardWire was used in 17 saphenous vein grafts in 16 patients. Particulate debris was subjected to microparticle size analysis (RapidVue, Beckman Coulter). All samples contained particulate debris. For both filter and GuardWire populations, most particles were <100 μm in longest dimension (87% and 90% of particles, respectively), and the distribution of particle sizes was identical. Total embolic load per lesion for both filters and GuardWire aspirates was also similar: median embolic load per filter was 16 mm
3
(range 2 to 84 mm
3
). Median embolic load per GuardWire was also 16 mm
3
(range 7 to 42 mm
3
). Histopathologic analysis demonstrated that most samples contained plaque elements and platelet-rich thrombus.
Conclusions—
During saphenous vein graft interventions, particulate retrieved with a vascular filtering device or an occlusion balloon was similar in amount and character. This supports the notion that unless soluble mediators play an important role in adverse acute clinical events after stenting, the clinical efficacy of filtering devices may be equal to that of occlusion devices.
Collapse
Affiliation(s)
- Campbell Rogers
- Cardiovascular Division, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St, Boston, Mass 02115, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Li SSL, Lam CW, So YC, Wong CH, Yiu SF, Ho D, Chan KW, Chan KT. The use of a distal occlusion balloon protection device in acute coronary syndrome. Int J Cardiol 2003; 92:281-4. [PMID: 14659866 DOI: 10.1016/s0167-5273(03)00097-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
We report our early experience in using the PercuSurge GuardWire Plus system as a distal protection device in patients with acute coronary syndrome and acute myocardial infarction. Forty-three patients received percutaneous coronary intervention with the GuardWire Plus system. Thirteen had unstable angina, five had non-Q myocardial infarction and 25 had ST segment elevation myocardial infarction. Forty-one target lesions were in native coronary vessels and two were in saphenous vein grafts. Total occlusion occurred in 18 patients. The mean occlusion time by the distal protective balloon was 262.8 +/- 114.1 s. Preoperatively, TIMI 0 flow was present in 18, TIMI II flow in two and TIMI III flow in 23 patients. Post-operatively, TIMI II and TIMI III flow were established in two and 41 patients, respectively. All procedures were successful and the GuardWire Plus system was successfully deployed in all but two patients. There was no procedure-related major adverse clinical event. There was no major adverse clinical event at 30 days. There was no device-related complication. We believe that the GuardWire Plus system is safe and feasible in patients with acute coronary syndrome and acute myocardial infarction.
Collapse
Affiliation(s)
- Steven S L Li
- Division of Cardiology, Department of Medicine, Queen Elizabeth Hospital, Kowloon, Hong Kong.
| | | | | | | | | | | | | | | |
Collapse
|
35
|
Huang Z, Katoh O, Nakamura S, Negoro S, Kobayashi T, Tanigawa J. Evaluation of the percusurge guardwire plus temporary occlusion and aspiration system during primary angioplasty in acute myocardial infarction. Catheter Cardiovasc Interv 2003; 60:443-51. [PMID: 14624419 DOI: 10.1002/ccd.10691] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Thirty patients with acute myocardial infarction (AMI) underwent primary angioplasty under distal protection of PercuSurge GuardWire Plus Temporary Occlusion and Aspiration System. Before angioplasty, protection of the distal circulation was achieved with the system, followed by balloon angioplasty and/or stenting and debris aspiration. Technical device success was 100%. Distal occlusion was well tolerated in all patients. Mean total distal occlusion time was 7.3 +/- 5.4 min. Macroscopically visible debris was aspirated from 29 cases (96.7%). Postprocedural Thrombolysis in Myocardial Infarction flow grade 3 was achieved in all cases (100%, vs. 16.7% at baseline). Myocardial blush flow grade 3 was achieved in 26 cases (86.7%). Regression of ST segment elevation >/= 50% was shown in 23 cases (76.7%). No patient developed angiographic evidence of no-reflow or distal embolization. Both angiographic and procedural success were 100%. The system is feasible, safe, and effective for distal protection against embolism during primary angioplasty in AMI.
Collapse
Affiliation(s)
- Zheng Huang
- Cardiovascular Center, Kyoto Katsura Hospital, Japan.
| | | | | | | | | | | |
Collapse
|
36
|
Wolfram R, Leborgne L, Cheneau E, Pichard A, Satler L, Kent K, Waksman R. Comparison of creatine kinase elevation and outcome of comparison of percutaneous coronary intervention for saphenous vein graft in-stent restenosis versus de novo stenosis. Am J Cardiol 2003; 92:980-3. [PMID: 14556879 DOI: 10.1016/s0002-9149(03)00984-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Percutaneous coronary intervention of saphenous vein grafts is associated with distal embolization. We aimed to compare potential differences in patients undergoing percutaneous coronary intervention for in-stent restenosis with de novo saphenous vein graft lesions. Myocardial necrosis was associated with higher mortality regardless of lesion type.
Collapse
|
37
|
Gaitonde RS, Sharma N, von der Lohe E, Kalaria VG. Combined distal embolization protection and rheolytic thrombectomy to facilitate percutaneous revascularization of totally occluded saphenous vein grafts. Catheter Cardiovasc Interv 2003; 60:212-7. [PMID: 14517927 DOI: 10.1002/ccd.10609] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Totally occluded saphenous vein grafts are difficult to treat percutaneously with a higher likelihood of distal embolization and slow-flow or no-reflow during percutaneous interventions. The PercuSurge system, which utilizes a distal balloon occlusive device, has been shown to improve clinical outcomes during saphenous vein graft (SVG) interventions. This device may not be optimal in the setting of heavy thrombus or debris burden, a situation frequently encountered in totally occluded SVGs. Rheolytic thrombectomy facilitates percutaneous interventions by effectively removing intraluminal thrombus and debris but lacks distal embolization protection. We report our experience with the synergistic use of balloon-based distal embolization protection (PercuSurge) and rheolytic thrombectomy (AngioJet) to optimize percutaneous revascularization of totally occluded SVGs.
Collapse
Affiliation(s)
- Rajdeep S Gaitonde
- Krannert Institute of Cardiology, Clarian Cardiovascular Center, Department of Medicine, Indiana University School of Medicine, Indianapolis, Indiana 46202, USA
| | | | | | | |
Collapse
|
38
|
Orrego PS, Delgado A, Piccalò G, Salvadè P, Bonacina E, Klugmann S. Distal protection in native coronary arteries during primary angioplasty in acute myocardial infarction: Single-center experience. Catheter Cardiovasc Interv 2003; 60:152-8. [PMID: 14517917 DOI: 10.1002/ccd.10638] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Distal embolization of plaque or thrombotic debris is one of the mechanisms involved in the ischemia/reperfusion injury during primary percutaneous intervention for acute occlusion of a native coronary artery. We tested the clinical application of maximal antiplatelet therapy with abciximab combined with one of two different systems of mechanical distal protection: balloon occlusion and aspiration (PercuSurge) in 24 cases and a distal filter (FilterWire Ex) in 10 cases. Feasibility, technical limitations, and pitfalls are described.
Collapse
Affiliation(s)
- Pedro Silva Orrego
- Department of Cardiology, "A De Gasperis," Niguarda Hospital, Milan, Italy.
| | | | | | | | | | | |
Collapse
|
39
|
Stone GW, Rogers C, Hermiller J, Feldman R, Hall P, Haber R, Masud A, Cambier P, Caputo RP, Turco M, Kovach R, Brodie B, Herrmann HC, Kuntz RE, Popma JJ, Ramee S, Cox DA. Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts. Circulation 2003; 108:548-53. [PMID: 12874191 DOI: 10.1161/01.cir.0000080894.51311.0a] [Citation(s) in RCA: 320] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND The high rate of periprocedural complications resulting from atherothrombotic embolization after percutaneous intervention in diseased saphenous vein grafts is reduced by distal microcirculatory protection using a balloon occlusion and aspiration system. Whether filter-based catheters, which offer the inherent advantages of maintained perfusion and ease of use, are as effective for this purpose has not been established. METHODS AND RESULTS A total of 651 patients undergoing percutaneous intervention of 682 saphenous vein graft lesions were prospectively randomized to distal protection with the filter-based FilterWire EX versus the GuardWire balloon occlusion and aspiration system. Device success was 95.5% and 97.2% with the FilterWire EX and GuardWire, respectively (P=0.25). Postprocedural measures of epicardial flow and angiographic complications were similar between the 2 groups, although bailout IIb/IIIa inhibitors were required slightly less frequently in the FilterWire EX group (0% versus 1.5%, P=0.03). The primary end point, the composite incidence of death, myocardial infarction, or target vessel revascularization at 30 days, occurred in 9.9% of FilterWire EX patients and 11.6% of GuardWire patients (difference [95% CI]=-1.7% [-6.4%, 3.1%]; P for superiority=0.53, P for noninferiority=0.0008). CONCLUSIONS Distal protection with the FilterWire EX may be safely used as an adjunct to percutaneous intervention of diseased saphenous vein grafts and, compared with distal protection with the GuardWire balloon occlusion and aspiration system, results in similar rates of major adverse cardiac events at 30 days.
Collapse
Affiliation(s)
- Gregg W Stone
- Cardiovascular Research Foundation and Lenox Hill Heart and Vascular Institute, 55 E 59th St, 6th Floor, New York, NY 10022, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Abstract
Atherosclerotic plaque rupture is a key event in the pathogenesis of acute coronary syndromes and during coronary interventions. However, it does not always result in complete thrombotic occlusion of the entire epicardial coronary artery with subsequent acute myocardial infarction; in milder forms the result can be embolization of atherosclerotic and thrombotic debris into the coronary microcirculation. This review summarizes the available morphological evidence for coronary microembolization in patients who died from coronary artery disease, most notably from sudden death, and then goes on to address the experimental pathophysiology of coronary microembolization in animal models of acute coronary syndromes and heart failure. Finally, the review presents the available clinical evidence for coronary microembolization in patients, highlights its key features (ie, arrhythmias, contractile dysfunction, infarctlets and reduced coronary reserve) and addresses its prevention by mechanical protection devices and glycoprotein IIb/IIIa antagonism.
Collapse
Affiliation(s)
- Andreas Skyschally
- Institut für Pathophysiologie, Zentrum für Innere Medizin, Universitätsklinikum Essen, Germany
| | | | | |
Collapse
|
41
|
Kornowski R, Assali A. Use of filterwire EX for distal embolic protection during complex percutaneous coronary interventions: four case studies. Catheter Cardiovasc Interv 2003; 58:364-9. [PMID: 12594704 DOI: 10.1002/ccd.10447] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We describe four successful cases demonstrating the use of a novel filter-guidewire (FilterWire EX) during complex percutaneous coronary interventions in saphenous vein grafts (n = 3) and native coronary artery (n = 1) for prevention of distal embolization and consequently myonecrosis.
Collapse
Affiliation(s)
- Ran Kornowski
- Cardiac Catheterization Laboratories, Rabin Medical Center, Petach Tikva, Israel.
| | | |
Collapse
|
42
|
Kereiakes DJ. Platelet glycoprotein IIb/IIIa inhibition and atheroembolism during bypass graft angioplasty: a cup half full. Circulation 2002; 106:2994-6. [PMID: 12473539 DOI: 10.1161/01.cir.0000041222.31560.65] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|