1
|
Liang C, Yan H. Methods of Corneal Vertex Centration and Evaluation of Effective Optical Zone in Small Incision Lenticule Extraction. Ophthalmic Res 2023; 66:717-726. [PMID: 36917962 DOI: 10.1159/000529922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 02/20/2023] [Indexed: 03/16/2023]
Abstract
Inappropriate small incision lenticule extraction (SMILE) centration methods can affect the decentration of the effective optical zone (EOZ) after operation, which can subsequently lead to the decline of postoperative visual quality. We aimed to provide an overview of corneal vertex (CV) centration methods and an evaluation of the size and decentration of the EOZ in SMILE. We described the CV centration methods for patients with myopia, myopic astigmatism, hyperopia, and large kappa angle. The measurement methods of the EOZ were evaluated from the aspects of corneal morphology and corneal refractive power. Additionally, we summarized the advantages and disadvantages of measuring decentration based on topographic mapping and intraoperative video-captured images. Finally, we discussed the relationship between the EOZ and visual quality. Based on our review, clinicians should consider the following when choosing CV centration methods and evaluating EOZ postoperatively. First, the tear film mark center or topographic map comparison method is preferred for the correction of myopia, low myopic astigmatism, hyperopia, and large kappa angle (>0.2 mm). Triple marking centration is recommended for high myopic astigmatism (-3.5 diopters). Second, the total corneal power better reflects the change in refractive power than the topographic method. The measurement of the area rather than the diameter of the total corneal refractive power is more suitable for the evaluation of noncircular EOZs after high myopia astigmatism (<-2.0 diopters). Third, for the evaluation of decentration, the tangential curvature difference map method is preferred as it is not influenced by offset pupils. Finally, a large EOZ after SMILE may improve patient tolerance to decentration.
Collapse
Affiliation(s)
- Chen Liang
- Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Xi'an, China,
- Department of Ophthalmology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China,
| | - Hong Yan
- Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Xi'an, China
| |
Collapse
|
2
|
Keller PR, van Saarloos PP. Perspectives on corneal topography: a review of videokeratoscopy. Clin Exp Optom 2021. [DOI: 10.1111/j.1444-0938.1997.tb04843.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Affiliation(s)
- Peter R Keller
- Centre for Ophthalmology and Visual Science, Lions Eye Institute
| | | |
Collapse
|
3
|
Liu S, Zhang X, You Z, Zhou X. Comparison of the Distribution of Lenticule Decentration Following SMILE by Pupil Center or Tear Film Mark Centration. J Refract Surg 2021; 36:239-246. [PMID: 32267954 DOI: 10.3928/1081597x-20200310-01] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Accepted: 03/10/2020] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate lenticule decentration following small incision lenticule extraction (SMILE) via the pupil center or tear film mark centration method and compare induction of corneal higher order aberrations (HOAs) between the two methods. METHODS This study analyzed decentration values obtained from tangential topography difference maps of 100 eyes (100 patients) undergoing SMILE with the pupil center (n = 50) or tear film mark (n = 50) centration method. Total HOAs and component aberrations were measured preoperatively and 6 months postoperatively. Relationships between the magnitudes of decentration and induced corneal HOAs were assessed. RESULTS Both vertical and total decentered displacement were significantly different (P < .001) between the two centration groups. A significant relationship between the preoperative pupillary offset and decentration was noted in the pupil center group (P < .001), but not in the tear film mark group (P = .530). Significantly greater induction of total HOAs, coma, and vertical coma (all P < .001), as well as horizontal coma (P = .001) and spherical aberration (P = .023), were observed in the pupil center group. Association between the total decentered displacement and induced total HOAs (P < .001), as well as all other significantly increased phenomena, was also significant in the pupil center group. Differences in decentered displacement and induced corneal HOAs were significant for preoperative pupillary offset (angle kappa) greater than 200 µm, but not for angle kappa less than 200 µm. CONCLUSIONS SMILE with tear film mark centration can yield improved treatment centration and less induction of total HOAs, coma, and spherical aberrations. [J Refract Surg. 2020;36(4):239-246.].
Collapse
|
4
|
Abstract
To evaluate intraoperative decentration from pupil center and kappa intercept during small incision lenticule extraction (SMILE) and its impact on visual outcomes.This was a retrospective noncomparative case series. A total of 164 eyes that underwent SMILE at the Singapore National Eye Center were included. Screen captures of intraoperative videos were analyzed. Preoperative and 3 month postoperative vision and refractive data were analyzed against decentration.The mean preoperative spherical equivalent (SE) was -5.84 ± 1.77. The mean decentration from the pupil center and from kappa intercept were 0.13 ± 0.06 mm and 0.47mm ± 0.25 mm, respectively. For efficacy and predictability, 69.6% and 95.0% of eyes achieved a visual acuity (VA) of 20/20 and 20/30, respectively, while 83.8% and 97.2% of eyes were within ±0.5D and ±1.0D of the targeted SE. When analyzed across 3 groups of decentration from the pupil center (<0.1 mm, 0.1-0.2 mm, and >0.2 mm), there was no statistically significant association between decentration, safety, efficacy, and predictability. When analyzed across 4 groups of decentration from kappa intercept (<0.2 mm, 0.2-<0.4 mm, 0.4-<0.6 mm, and ≥0.6 mm), there was a trend toward higher efficacy for eyes with decentration of kappa intercept between 0.4 and <0.6 mm (P = .097). A total of 85.4% of eyes in the 0.4 to <0.6 mm group had unaided distance VA of 20/20 or better, as compared to only 57.8% of eyes in ≥0.6 mm group.Decentration of 0.13 mm from the pupil center does not result in compromised visual outcomes. Decentration of greater than 0.6 mm from the kappa intercept may result in compromised visual outcomes. There was a trend toward better efficacy in eyes which had decentered treatment from 0.4 to <0.6 mm from the kappa intercept. Patients with a large kappa intercept (>0.6 mm) should have their lenticule created 0.4 to 0.6 mm from the kappa intercept and not close to the pupil.
Collapse
Affiliation(s)
- John X. Wong
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute
| | - Elizabeth P. Wong
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute
| | | | - Jodhbir S. Mehta
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute
- Singapore National Eye Centre, Singapore
- Department of Clinical Sciences, Duke-NUS Graduate Medical School
- School of Material Science and Engineering and School of Mechanical and Aerospace Engineering, Nanyang Technological University
| |
Collapse
|
5
|
Khakshoor H, McCaughey MV, Vejdani AH, Daneshvar R, Moshirfar M. Use of angle kappa in myopic photorefractive keratectomy. Clin Ophthalmol 2015; 9:193-5. [PMID: 25678767 PMCID: PMC4322872 DOI: 10.2147/opth.s70690] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To explore utilization of the coaxially sighted corneal light reflex (CSCLR) for centration during myopic photorefractive keratectomy (PRK) for patients with relatively high angle kappa (κ) values. METHODS Patients were stratified into two groups preoperatively, on the basis of angle κ values. Group A was composed of 166 eyes with an angle κ value <5°. Group B consisted of 182 eyes with an angle κ value >5°. Intraoperative centering of ablation was performed within group A by utilizing the pupillary center, and within group B by using the CSCLR. Visual acuities were evaluated and compared at 6 months and 12 months postoperatively between groups. RESULTS Mean uncorrected visual acuities (UCVA) for all patients at 6 months and 12 months were -0.073 logMAR and -0.080 logMAR, respectively. A total of 98.9% of patients had a UCVA of 0.00 logMAR (≈20/20 Snellen) 12 months postoperatively. There was not a significant between-group difference in regard to residual refractive error at 6 months or 12 months (P=0.53 and P=0.97), or in UCVA at 6 months and 12 months (P=0.76 and P=0.17). There were no subjective complaints of monocular diplopia, glare, or haloes within either group at any time during follow-up. CONCLUSION Availing use of the CSCLR for centration of ablation within myopic patients with high angle κ values may aid in providing better refractive outcomes after performance of PRK.
Collapse
Affiliation(s)
- Hamid Khakshoor
- Department of Ophthalmology, The University of Mashhad, Mashhad, Iran
| | - Michael V McCaughey
- Department of Ophthalmology, The University of New Mexico, School of Medicine, Albuquerque, NM, USA
| | | | - Ramin Daneshvar
- Department of Ophthalmology, The University of Mashhad, Mashhad, Iran
| | - Majid Moshirfar
- Department of Ophthalmology, Francis I Proctor Foundation, University of California San Francisco, CA, USA
| |
Collapse
|
6
|
Lazaridis A, Droutsas K, Sekundo W. Topographic analysis of the centration of the treatment zone after SMILE for myopia and comparison to FS-LASIK: subjective versus objective alignment. J Refract Surg 2014; 30:680-6. [PMID: 25291751 DOI: 10.3928/1081597x-20140903-04] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2014] [Accepted: 06/25/2014] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the centration of the treatment zone after small incision lenticule extraction (SMILE) and compare it to femtosecond laser-assisted LASIK (FS-LASIK). METHODS Sixty-nine myopic eyes of 36 patients who underwent SMILE were compared to 69 myopic eyes of 36 patients treated with FS-LASIK. All procedures were performed by a single surgeon using the VisuMax platform (Carl Zeiss Meditec, Jena, Germany). The Pentacam (Oculus Optikgeräte GmbH, Wetzlar, Germany) was used for preoperative and postoperative topography and pachymetry. The centration of the treatment zone was estimated pachymetrically by the distance of the thickest point on the corneal thickness differential map from the topographical center of the entrance pupil and the coaxial corneal light reflex. RESULTS In SMILE cases, the mean decentration of the lenticule from the center of the entrance pupil was 0.326 ± 0.196 mm (range: 0.014 to 1.062 mm), whereas the distribution of the lenticule centers demonstrated a nasalization pattern. In FS-LASIK cases, this value was 0.452 ± 0.224 mm (range: 0.02 to 1.040 mm), whereas the ablation centers were distributed randomly. In relation to the coaxial corneal light reflex, the decentration in SMILE was 0.315 ± 0.211 mm (range: 0.0 to 1.131 mm), whereas FS-LASIK eyes demonstrated a mean decentration of 0.516 ± 0.254 mm (range: 0.103 to 1.265 mm). The decentration from the reference point of its technique (coaxial corneal light reflex in SMILE, the entrance pupil center in FS-LASIK) was significantly more extended in the FS-LASIK group (P < .001). CONCLUSIONS The centration of the treatment zone as measured by the Pentacam was better for patient-controlled fixation during SMILE than active eye tracker-assisted FS-LASIK.
Collapse
|
7
|
Park DY, Lee SB. Influences of Cylindrical Correction Amount of PRK on Accuracy of Geometric Corneal Center-Adjusted Ablation Centration. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2012. [DOI: 10.3341/jkos.2012.53.1.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Dae-Young Park
- Department of Ophthalmology, Yeungnam University College of Medicine, Daegu, Korea
| | - Sang-Bumm Lee
- Department of Ophthalmology, Yeungnam University College of Medicine, Daegu, Korea
| |
Collapse
|
8
|
Hashemi H, KhabazKhoob M, Yazdani K, Mehravaran S, Jafarzadehpur E, Fotouhi A. Distribution of angle kappa measurements with Orbscan II in a population-based survey. J Refract Surg 2010; 26:966-71. [PMID: 20128530 DOI: 10.3928/1081597x-20100114-06] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2009] [Accepted: 12/08/2009] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine the mean angle kappa and its determinants in the population of Tehran, Iran. METHODS In a cross-sectional survey with random cluster sampling, a total of 442 participants aged >14 years were selected from 4 municipality districts of Tehran for Orbscan acquisitions. Exclusion criteria were history of eye surgery for refractive errors, cataract or glaucoma, and use of topical medication or any type of contact lens at the time of the study. Mean angle kappa in different age and gender groups and its association with other factors was assessed. Considering the high correlation between the right and left eyes, only results of the right eyes are presented. RESULTS After applying exclusion criteria, 800 eyes (399 right eyes and 401 left eyes) were examined. Mean participant age was 40.6±16.8 years (range: 14 to 81 years), and 38.8% of eyes were from men. Mean angle kappa was 5.46±1.33° in total; 5.41±1.32° in men and 5.49±1.34° in women (P=.558). It decreased significantly with age; 0.015°/year (P<.001). In individuals with myopia, emmetropia, and hypermetropia, the mean value was 5.13±1.50°, 5.72±1.10°, and 5.52±1.19°, respectively (P=.025); the post-hoc test indicated this was due to the difference between emmetropes and myopes. CONCLUSIONS According to our results, angle kappa reduces with age, and the inter-gender difference is not significant. Largest angle kappas were seen among individuals with emmetropia. Angle kappas were larger in the hypermetropic population compared to the myopic population.
Collapse
Affiliation(s)
- Hassan Hashemi
- Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | | | | | | | | | | |
Collapse
|
9
|
Lee SB, Hwang BS, Lee J. Effects of decentration of photorefractive keratectomy on the induction of higher order wavefront aberrations. J Refract Surg 2009; 26:731-43. [PMID: 20027991 DOI: 10.3928/1081597x-20091209-01] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2008] [Accepted: 10/27/2009] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the effects of ablation decentration on the induction of higher order wavefront aberrations (HOAs) in active eye-tracker-assisted myopic photorefractive keratectomy (PRK) using the VISX STAR S4 laser with ActiveTrak (Abbott Medical Optics [AMO]). METHODS Ninety-four myopic eyes (53 patients) were divided into three groups according to ablation decentration (group 1, ≤0.15 mm, 20 eyes; group 2, >0.15 to ≤0.30 mm, 54 eyes; and group 3, >0.30 mm, 20 eyes). The distances of ablation centers from the centers of the entrance pupils were analyzed using corneal topography. Wavefront errors were measured preoperatively and at 6 months after PRK using a VISX WaveScan aberrometer (AMO). Statistical analysis was performed to assess the influence of ablation decentration on PRK-induced HOAs. RESULTS The mean decentration was 0.23±0.10 mm (range: 0.04 to 0.52 7 mm). The magnitude of all HOAs was significantly increased at 6 months postoperatively (P<.05). Increases in PRK-induced HOAs including total HOA, coma, and spherical aberration were significantly different among the three groups (P<.05). Statistically significant differences were noted between pairs of data in group 1 versus group 3 for total HOA (P=.015), coma (P=.038), and spherical aberration (P=.038), and group 2 versus group 3 for coma (P=.049). CONCLUSIONS Ablation decentration >0.30 mm from the center of the entrance pupil was associated with greater induction of total HOA, coma, and spherical aberration after PRK, as compared with ablation decentration <0.15 mm. In addition, ablation decentration has a more significant influence on coma-inducing effects.
Collapse
Affiliation(s)
- Sang-Bumm Lee
- Department of Ophthalmology, Yeungnam University College of Medicine, Daegu, Korea.
| | | | | |
Collapse
|
10
|
Carr JD, Hersh PS. Excimer Laser Technology: Key Concepts for the Ophthalmologist. Semin Ophthalmol 2009. [DOI: 10.3109/08820539609063814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
11
|
McDonald M, Wyse T. Photorefractive Keratectomy Complications and Their Management. Semin Ophthalmol 2009. [DOI: 10.3109/08820539609063820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
12
|
Novel Objective Method for Comparing Ablation Centration With and Without Pupil Tracking Following Myopic Laser In Situ Keratomileusis Using the Bausch & Lomb Technolas 217A. Cornea 2009; 28:616-25. [DOI: 10.1097/ico.0b013e31819ba450] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
13
|
Padmanabhan P, Mrochen M, Viswanathan D, Basuthkar S. Wavefront aberrations in eyes with decentered ablations. J Cataract Refract Surg 2009; 35:695-702. [PMID: 19304091 DOI: 10.1016/j.jcrs.2008.12.022] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2008] [Revised: 12/16/2008] [Accepted: 12/16/2008] [Indexed: 10/21/2022]
Abstract
PURPOSE To compare the refractive and functional outcomes and wavefront profiles in eyes with decentered ablations and eyes with well-centered ablations. SETTING Medical Research Foundation, Chennai, Tamil Nadu, India. METHODS This retrospective analysis comprised eyes with topographically diagnosed decentered ablations after laser in situ keratomileusis (LASIK). Refraction, contrast sensitivity, and ocular wavefront aberrations were measured preoperatively and 1 month postoperatively. The induced aberrations in these eyes were compared with those in eyes with well-centered ablations. RESULTS Forty-six eyes (38 patients) had decentered ablations and 60 eyes (32 patients), well-centered ablations. The mean decentration in the study group was 0.86 mm +/- 0.29 (SD) (range 0.35 to 1.61 mm). There was no significant correlation between decentration and attempted refractive correction. There was, however, a statistically significant (P<.05) linear correlation between the distance of decentration and the magnitude of induced tilt (r = -0.31), coma (r = -0.41), and secondary astigmatism (r = 0.36). The induced changes in tilt, oblique astigmatism, vertical coma, and spherical aberration were statistically significantly higher in eyes with decentered ablations than in eyes with well-centered ablations. A statistically significantly higher percentage of eyes (87%) with well-centered ablations than eyes with decentered ablations (70%) had a postoperative uncorrected visual acuity (UCVA) of 20/20 or better. There was no significant difference in contrast sensitivity between groups. CONCLUSION Eyes with decentered ablations had a significantly higher magnitude of induced aberrations and lower UCVA than eyes with well-centered ablations.
Collapse
|
14
|
Maldonado MJ, Nieto JC, Piñero DP. Advances in technologies for laser-assisted in situ keratomileusis (LASIK) surgery. Expert Rev Med Devices 2008; 5:209-29. [PMID: 18331182 DOI: 10.1586/17434440.5.2.209] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Laser-assisted in situ keratomileusis (LASIK) has become the most widely used form of refractive surgery today. The objective of this surgical technique is to modify the anterior corneal shape by ablating tissue from the stroma by means of the excimer laser after creating a hinged corneal flap. This way, we are able to change the refractive status of the patient, providing better unaided vision. Continuous improvements in the original technique have made the surgical procedure safer, more accurate and repeatable. These progressions are due to the development of novel technologies that are the responsible for new surgical instrumentation, which makes the surgical procedure easier for the surgeon, and better excimer laser ablation algorithms, which increase the optical quality of the ablation and thus the safety of the vision correction procedure. This article aims to describe the more relevant advances in LASIK that have played an important role in the spread and popularity of this technique.
Collapse
Affiliation(s)
- Miguel J Maldonado
- Department of Ophthalmology, Clínica Universitaria, University of Navarra, Avda Pio XII, 36, 31080, Pamplona, Spain.
| | | | | |
Collapse
|
15
|
Ablation Centration After Active Eye Tracker-assisted LASIK and Comparison of Flying-spot and Broad-beam Laser. J Refract Surg 2008; 24:371-6. [DOI: 10.3928/1081597x-20080401-10] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
16
|
Basmak H, Sahin A, Yildirim N, Papakostas TD, Kanellopoulos AJ. Measurement of Angle Kappa With Synoptophore and Orbscan II in a Normal Population. J Refract Surg 2007; 23:456-60. [PMID: 17523505 DOI: 10.3928/1081-597x-20070501-06] [Citation(s) in RCA: 96] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To obtain normative values of angle kappa in a normal population by synoptophore and Orbscan II and to compare the reliability of these devices. METHODS Three hundred consecutive healthy individuals were enrolled in the study. A complete orthoptic and ophthalmologic examination was performed. Synoptophore and Orbscan II corneal topography were used to measure angle kappa. To evaluate the association of the angle kappa and refraction measures, individuals were further classified according to the degree of myopia and hyperopia. The spherical equivalent error measures were grouped into six categories: > or = -3.00 diopters (D); -2.75 to -1.50 D; -1.25 to -0.50 D; +0.50 to +1.25 D; +1.50 to +2.75 D; and > or = +3.00 D. Paired t test and Pearson's correlation test were used for statistical analysis. RESULTS The mean age of the individuals was 28.74 +/- 1.63 years (range: 20 to 40 years). The angle kappa values obtained by synoptophore and Orbscan II were normally distributed. In the myopic group, angle kappa values decreased significantly towards negative refractive errors. In contrast, a correlation existed between large positive angles and positive refractive errors in the hyperopic group. Angle kappa values obtained by Orbscan II were significantly higher in all groups when compared to synoptophore (P < .0001). A significant correlation was noted between synoptophore and Orbscan II measurements (r = 0.932, P < .0001). CONCLUSIONS A significant correlation exists between positive refractive errors and large positive angle kappa values. Refractive surgeons must take into account angle kappa, especially in hyperopic patients, to avoid complications related to decentration of the ablation zone.
Collapse
Affiliation(s)
- Hikmet Basmak
- Eskisehir Osmangazi University Hospitals, Department of Ophthalmology, Eskisehir, Turkey
| | | | | | | | | |
Collapse
|
17
|
Ou JI, Manche EE. Topographic Centration of Ablation After LASIK for Myopia Using the CustomVue VISX S4 Excimer Laser. J Refract Surg 2007; 23:193-7. [PMID: 17326359 DOI: 10.3928/1081-597x-20070201-12] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine the ablation centration, efficacy, predictability, and safety of CustomVue LASIK using the VISX S4 excimer laser for the treatment of myopia and myopic astigmatism. METHODS A retrospective review of 20 myopic eyes of 12 patients treated with LASIK CustomVue VISX S4 was conducted. Corneal topography was used to determine ablation centration. Primary outcome variables including manifest refraction, best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA), and complications were evaluated at 3 months postoperatively. RESULTS Mean decentration (from ablation zone to entrance pupil) was 0.23 +/- 0.08 mm at 3 months postoperatively. No eyes were decentered > 0.5 mm. Preoperatively, the mean spherical equivalent refraction was -4.81 +/- 11.39 diopters (D) (range: -6.75 to -2.25 D). At 3 months postoperatively, mean spherical equivalent refraction was -0.63 +/- 0.25 D (range: -2.00 to 0.25 D). Nineteen (95%) of 20 eyes had UCVA of 20/40 and 16 (80%) of 20 eyes had UCVA of 20/20 at 3 months postoperatively. Fourteen (70%) eyes were within +/- 0.50 D and 18 (90%) eyes were within +/- 1.00 D of emmetropia. No eye lost > 1 line of BSCVA. CONCLUSIONS Wavefront-guided LASIK using the CustomVue VISX S4 for myopic eyes results in minimal decentration ablation and effective, predictable, and safe visual outcomes.
Collapse
Affiliation(s)
- Judy I Ou
- Stanford University School of Medicine, Stanford, CA 94305, USA
| | | |
Collapse
|
18
|
Tsai YY, Tseng SH, Lin JM. Comparison of ablation centration in initial and retreatment active eye-tracker-assisted laser in situ keratomileusis and the effect on visual outcome. J Cataract Refract Surg 2004; 30:1521-5. [PMID: 15210232 DOI: 10.1016/j.jcrs.2003.11.039] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/10/2003] [Indexed: 10/26/2022]
Abstract
PURPOSE To evaluate the relationship between initial and retreatment ablation centers in active eye-tracker-assisted myopic laser in situ keratomileusis (LASIK) and determine whether the relationship between the 2 ablation centers influences the visual outcome after retreatment. SETTING Department of Ophthalmology, China Medical University Hospital, Taichung, Taiwan. METHODS This retrospective study comprised 21 eyes of 15 patients who had retreatment at least 3 months after primary myopic LASIK by lifting the initial flap. Corneal topography and best corrected visual acuity (BCVA) were evaluated preoperatively and 3 months postoperatively. The ablation centration was analyzed by corneal topography preoperatively and at 3 months. RESULTS The mean decentration of the primary treatment was 0.43 mm +/- 0.21 (SD) and of the retreatment, 0.34 +/- 0.15 mm. There was no significant difference between them (P =.07). The 2 ablation centers were close each other. The mean distance between the 2 ablation centers was 0.29 +/- 0.18 mm and the mean angle between them, 39.7 +/- 46.2 degrees. The BCVA was unchanged after retreatment regardless of the relationship between the 2 ablation centers. CONCLUSIONS With an active eye-tracking system, the retreatment center was not only close to the pupil center but also close to the primary ablation center. Regardless of the relationship between the 2 ablation centers, the BCVA did not change if the retreatment ablation was well centered.
Collapse
Affiliation(s)
- Yi-Yu Tsai
- Department of Ophthalmology, China Medical University Hospital, 2 Yuh-Der Road, Taichung, Taiwan.
| | | | | |
Collapse
|
19
|
Giaconi JA, Manche EE. Ablation Centration in Laser in situ Keratomileusis for Hyperopia: Comparison of VISX S3 ActiveTrak and VISX S2. J Refract Surg 2003; 19:629-35. [PMID: 14640427 DOI: 10.3928/1081-597x-20031101-04] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare ablation centration and outcome measurements in laser in situ keratomileusis (LASIK) for hyperopia using the pupil-tracking VISX S3 ActiveTrak or the nontracking VISX S2 excimer laser. METHODS In a retrospective study, 49 consecutively treated hyperopic eyes (32 patients) that had LASIK by the VISX StarS3 ActiveTrak were compared to 49 control-matched eyes treated with the VISX StarS2 without pupil-tracking. Primary outcome variables including ablation centration, uncorrected visual acuity, best spectacle-corrected visual acuity, manifest refraction, complications, and induced cylinder analyzed by vector analysis were evaluated 3 months postoperatively. RESULTS Hyperopic sphere ranged between plano and +5.50 D and cylinder between 0 and +2.75 D. Ninety-five of 98 eyes (96.9%) were available for analysis at 3 months. Of these 95, 52 eyes could be used for analysis of ablation centration. Mean decentration of the ablation zone from the entrance pupil was 0.30 +/- 0.20 mm in tracked eyes (n=31) and 0.41 +/- 0.39 mm in nontracked eyes (n=21), P=.17. Two eyes (6.5%) in the tracked group were significantly decentered between 0.5 and 1 mm from the pupil center. In the nontracked group, decentration was between 0.5 and 1 mm in one eye (4.8%) and greater than 1 mm in two eyes (9.5%). CONCLUSIONS Comparable ablation centration in LASIK for hyperopia was achieved between actively-tracked and nontracked eyes. Decentrations (greater than 1 mm) were not seen with a tracking system in this study. Visual and refractive results were similar between the VISX StarS3 ActiveTrak and VISX StarS2 laser systems.
Collapse
Affiliation(s)
- JoAnn A Giaconi
- Department of Ophthalmology, Stanford University, Stanford, CA 94305, USA
| | | |
Collapse
|
20
|
Abstract
PURPOSE OF REVIEW This article reviews the literature on pediatric refractive surgery from 1995 to 2003 and discusses the practical issues surrounding the application of modern refractive surgery to children. RECENT FINDINGS Preliminary data show that refractive surgery can be successfully performed in children and that the short term complication rate seems to be similar to that reported in adults. SUMMARY Refractive surgery may hold promise for cases in which traditional treatment methods have failed. Additional study is needed to define the role of refractive surgery in children and in the treatment of amblyopia and strabismus.
Collapse
Affiliation(s)
- Amy K Hutchinson
- Department of Ophthalmology, Emory University School of Medicine, Atlanta, Georgia, USA.
| |
Collapse
|
21
|
Giaconi JA, Manche EE. Ablation centration in myopic laser in situ keratomileusis. comparing the Visx S3 ActiveTrak and the Visx S2. J Cataract Refract Surg 2003; 29:1522-9. [PMID: 12954299 DOI: 10.1016/s0886-3350(03)00222-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
PURPOSE To compare ablation centration and outcome measurements in myopic laser in situ keratomileusis (LASIK) using the eye-tracking Visx S3 ActiveTrak and the nontracking Visx S2 excimer lasers. SETTING University-based refractive surgery practice. METHODS In a retrospective study, 71 consecutively treated myopic eyes that had LASIK with the Visx Star S3 ActiveTrak were compared to 71 control-matched eyes treated with the Visx Star S2 without pupil tracking. Primary outcome variables including ablation centration, uncorrected visual acuity, best spectacle-corrected visual acuity, manifest refraction, complications, and induced cylinder analyzed by vector analysis were evaluated 3 months postoperatively. RESULTS The myopia ranged from -1.50 to -11.25 diopters (D) and the cylinder, from +0.25 to +2.75 D. Ninety-four of 142 eyes (66%) were available for analysis at 3 months; 50 eyes could be used to analyze ablation centration. At 3 months, the mean decentration of the ablation zone from the entrance pupil was 0.22 mm +/- 0.20 (SD) in tracked eyes (n = 25) and 0.21 +/- 0.26 mm in nontracked eyes (n = 25) (P =.88). Three eyes (12%) in the tracked group were decentered 0.5 to 1.0 mm, and 1 eye (4%) in the nontracked group was decentered more than 1.0 mm. All other eyes were decentered less than 0.5 mm. There was an association in the tracked group between greater decentrations and higher levels of myopia (r = 0.67), but this association did not exist in the nontracked group (r = -0.03). CONCLUSION Comparable ablation centration as well as visual and refractive outcomes can be achieved with and without active eye tracking during myopic and astigmatic myopic LASIK.
Collapse
Affiliation(s)
- JoAnn A Giaconi
- Department of Ophthalmology, Stanford University, Stanford, California 94305, USA
| | | |
Collapse
|
22
|
Affiliation(s)
- J D Primack
- Massachusetts Eye and Ear Infirmary, Boston 02114, USA
| | | | | |
Collapse
|
23
|
Keskinbora HK. Long-term results of multizone photorefractive keratectomy for myopia of -6.0 to -10.0 diopters. J Cataract Refract Surg 2000; 26:1484-91. [PMID: 11033395 DOI: 10.1016/s0886-3350(00)00563-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the 4 year refractive outcome of multizone photorefractive keratectomy (PRK) in eyes with high myopia. SETTING ++SSK Okmeydani Education Hospital, Eye Clinic, Türkiye Hospital, Okmeydani, Istanbul. METHODS Three ablation zones were used in 92 eyes of 48 patients whose refractive errors were between -6.0 and -10.0 diopters (D) (mean spherical equivalent -7.42 D +/- 1.25 [SD]). The zones were between 4.5 and 6.0 mm based on the thickness of the cornea and the refractive correction. After the epithelium healed, dexamethasone was applied 4 times a day during the first postoperative week and then fluorometholone was applied 4 times a day for a minimum of 4 weeks. If hyperopia was found post-PRK, the steroid dose was gradually tapered. The patients were examined 1 and 3 days postoperatively, 1, 2, and 4 weeks, every 3 months for the first year, and then every 6 months. RESULTS All patients were overcorrected in the first postoperative week. At 2 and 3 weeks, the mean manifest refraction was closer to emmetropia. At 6 months, the refraction was stable. The mean spherical equivalent was -0.10 D at the end of the first year, and stabilization continued for 4 years. After the third month, the haze regressed gradually without requiring treatment. In 1 patient, herpes simplex keratitis developed and healed in a short time with topical antiviral therapy. Nineteen eyes regressed more than -1.0 D, 4 eyes were overcorrected, 4 eyes had central islands (at 6 months), and 2 eyes were undercorrected. Two eyes were retreated for regression; 1 eye was retreated for undercorrection and 1 eye, for central island. An uncorrected visual acuity of 20/40 or better was achieved in 79.2% of eyes, and 73.9% were within +/-1. 0 D of the intended correction. CONCLUSION ++Photorefractive keratectomy was effective in treating high myopia between -6.0 and -10.0 D. The induced refractive changes stabilized between 6 and 9 months. In most patients, no significant regression was found after this period.
Collapse
Affiliation(s)
- H K Keskinbora
- SSK Okmeydani Education Hospital, Eye Clinic, Istanbul Türkiye Hospital, Okmeydani, Istanbul, Turkey.
| |
Collapse
|
24
|
Tsai YY, Lin JM. Ablation centration after active eye-tracker-assisted photorefractive keratectomy and laser in situ keratomileusis. J Cataract Refract Surg 2000; 26:28-34. [PMID: 10646143 DOI: 10.1016/s0886-3350(99)00328-4] [Citation(s) in RCA: 65] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
PURPOSE To evaluate the ablation centration after active eye-tracker-assisted photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) and to investigate the effect of surgery, patient, and surgeon on the centration. SETTING Department of Ophthalmology, China Medical College Hospital, Taichung, Taiwan, Republic of China. METHODS This retrospective study comprised 177 eyes of 101 patients: 16 eyes had PRK and 161, LASIK. All laser treatments were performed with the aid of an eye tracker. The amount of decentration was analyzed by corneal topography. The factors influencing centration were divided into surgery related (PRK/LASIK), patient related (low/high myopia and effect of learning), and surgeon related (learning curve). RESULTS The mean decentration was 0.33 mm in PRK eyes and 0.35 mm in LASIK eyes. For the surgery-related factor, there was no significant difference between the PRK and LASIK eyes. For the patient-related factors, centration was better in the second eye (effect of learning) and decentration was more severe in eyes with high myopia (low/high myopia). For the surgeon-related factor, there was no significant difference between eyes that had the first 50 LASIK procedures and those that had the last 50 procedures. CONCLUSIONS An eye tracker, which makes the laser beam follow the eye's movements, helps to avoid severe decentration. This study showed, however, that an active eye-tracking system alone cannot ensure good centration. Patient cooperation and fixation are important.
Collapse
Affiliation(s)
- Y Y Tsai
- Department of Ophthalmology, China Medical College Hospital, Taichung, Republic of China
| | | |
Collapse
|
25
|
Haw WW, Alcorn DM, Manche EE. Excimer laser refractive surgery in the pediatric population. J Pediatr Ophthalmol Strabismus 1999; 36:173-7; quiz 206-7. [PMID: 10442722 DOI: 10.3928/0191-3913-19990701-04] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
- W W Haw
- Department of Ophthalmology, Stanford University School of Medicine, Calif 94305-5308, USA
| | | | | |
Collapse
|
26
|
Smolek MK, Oshika T, Klyce SD, Maeda N, Haight DH, McDonald MB. Topographic assessment of irregular astigmatism after photorefractive keratectomy. J Cataract Refract Surg 1998; 24:1079-86. [PMID: 9719967 DOI: 10.1016/s0886-3350(98)80101-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
OBJECTIVE To correlate new quantitative topographic indexes of corneal irregular astigmatism to best spectacle-corrected visual acuity (BSCVA) following excimer laser photorefractive keratectomy (PRK). SETTING Department of Ophthalmology, LSU Eye Center, and Refractive Surgery Center of the South, Ear, Nose & Throat Hospital, New Orleans, Louisiana; Manhattan Eye, Ear and Throat Hospital, New York, New York, USA. METHODS Videokeratography data (TMS-1) were obtained preoperatively and 1, 3, 6, 12, 18, and 24 months postoperatively from 100 eyes having PRK for low to mild myopia. Algorithms measured fine local irregularity with the surface regularity index (SRIp), varifocality with the coefficient of variation of corneal power (CVPp), and central islands with the elevation/depression magnitude (EDM). RESULTS The SRIp and CVPp increased after surgery and remained significantly higher than the preoperative levels throughout the 24 month follow-up (P < .05). The increase in EDM was significant from 1 to 6 months (P < .05) but not thereafter. Multiple regression analysis revealed that variables having a statistically significant relationship with postoperative BSCVA were CVPp and EDM at 1 month, CVPp at 3 months, and CVPp, haze, and age at 6 months. No statistically significant correlation between any measures of irregular astigmatism and BSCVA was found after 1 year of follow-up. CONCLUSION The quantitative measures used in this study are sensitive methods by which irregular astigmatism after keratorefractive procedures can be classified, evaluated, and compared.
Collapse
Affiliation(s)
- M K Smolek
- LSU Eye Center, New Orleans, Louisiana 70112, USA
| | | | | | | | | | | |
Collapse
|
27
|
Piovella M, Camesasca FI, Fattori C. Excimer laser photorefractive keratectomy for high myopia: four-year experience with a multiple zone technique. Ophthalmology 1997; 104:1554-65. [PMID: 9331191 DOI: 10.1016/s0161-6420(97)30096-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
PURPOSE The purpose of the study is to evaluate the results of the authors' 4-year experience with excimer laser photorefractive keratectomy (PRK) and multiple optical zone corneal ablation in highly myopic eyes. METHODS The authors retrospectively evaluated 56 eyes of 44 patients (mean refraction, -11.3 diopters [D]; range, -5.75 to -24.5 D) who underwent PRK with a Visx Model 20/20 laser (Visx, Santa Clara, CA). Preoperative visual acuity of 20/40 or better was present in 46 eyes. Corneal ablation was divided into concentric optical zones (4, 5, and 6 mm), allowing corrections of up to 18 D, with a refractive goal of within -1 D from emmetropia in 49 eyes. A hand-held fixation system was always used, and a nitrogen-blowing system (NBS) was used in the first 21 eyes only. RESULTS Before retreatment, the range of final cycloplegic refraction from emmetropia in eyes treated with NBS versus not was within +/-1 D in 6 (28.6%) and 15 eyes (44.1%), between -1.25 and -3 D in 5 (23.8%) and 14 eyes (41.1%), and more than -3 D in 10 (47.6%) and 5 eyes (14.7%), respectively. No lines of visual acuity were lost in 37 eyes (80.4%) with 20/40 or better visual acuity before surgery. Three eyes showed vision loss due to worsening of myopic maculopathy and one due to corneal haze. Correction stabilized within 9 months, and at a mean time of 25.6 months, the correction attained was of -8.5 +/- 3.6 D, achieving 90.3% of attempted correction. Eyes with preoperative myopia less than -10 D (n = 27) showed regression less than -1 D in 8 eyes (29.6%), between -1.25 and -3.00 D in 5 eyes (18.5%), and greater than -3.00 D in 1 eye (3.7%); eyes with more than -10 D (n = 29) regressed in 3 (10.3%), 6 (20.7%), and 1 eye (3.4%), respectively. Severe haze was observed in 11 eyes (19.6%) 3 months after surgery. Two eyes showed decentration greater than 1.5 mm. At last examination, night driving problems were reported by 12 (41.4%) of 29 patients evaluated who drive. CONCLUSIONS After the NBS was eliminated, the multiple-zone technique achieved a long-term, stable 83.1% reduction of preoperative myopia. Patients with severe myopia appreciated reduction of most of the refractive defect, although perception of halos was noted by 16 patients.
Collapse
Affiliation(s)
- M Piovella
- Centro di Microchirurgia Ambulatoriale, Monza, Italy
| | | | | |
Collapse
|
28
|
Mulhern MG, Foley-Nolan A, O'Keefe M, Condon PI. Topographical analysis of ablation centration after excimer laser photorefractive keratectomy and laser in situ keratomileusis for high myopia. J Cataract Refract Surg 1997; 23:488-94. [PMID: 9209982 DOI: 10.1016/s0886-3350(97)80204-0] [Citation(s) in RCA: 62] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE To evaluate the ablation centration after photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) for high myopia and to assess the association between decentration and best corrected visual acuity (BCVA), glare, monocular diplopia, and halo phenomenon. SETTING Mater Private Hospital, Dublin, Ireland. METHODS Corneal topography was used to analyze centration in two groups of patients with myopia of more than 6.0 diopters: 18 had PRK and 18, LASIK. A standardized questionnaire assessed the preoperative and postoperative prevalence of glare, monocular diplopia, and halo phenomenon. RESULTS "Significant" ablation decentration (0.5 mm) in the LASIK group (1.33 mm) was almost twice that in the PRK group (0.75 mm). Glare increased from 27% preoperatively to 42% in the PRK group; monocular diplopia increased in the LASIK group. Halo phenomenon decreased after both procedures. CONCLUSION Laser in situ keratomileusis represents a step forward in the surgical correction of high myopia, but the accuracy of the corneal ablation location must be improved. Suction ring fixation of the globe or real time tracking systems may help improve centration.
Collapse
|
29
|
|
30
|
Letters to the editor. Clin Exp Optom 1996. [DOI: 10.1111/j.1444-0938.1996.tb04965.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
31
|
Author's reply. Ophthalmology 1995. [DOI: 10.1016/s0161-6420(95)30877-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|