• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4604951)   Today's Articles (270)   Subscriber (49373)
For: Jeppesen MT, Hansen EH. Flow-injection fluorimetric assay of nitrogen-containing substrates by on-line enzymatic generation of ammonia. Anal Chim Acta 1991. [DOI: 10.1016/s0003-2670(00)80206-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Number Cited by Other Article(s)
1
Zuman P. Reactions of Orthophthalaldehyde and Related Compounds with Amino Acids. ANAL LETT 2005. [DOI: 10.1081/al-200060857] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
2
Zuman P. Reactions of orthophthalaldehyde with nucleophiles. Chem Rev 2004;104:3217-38. [PMID: 15250740 DOI: 10.1021/cr0304424] [Citation(s) in RCA: 88] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
3
Magalhães JMCS, Machado AASC. Array of potentiometric sensors for the analysis of creatinine in urine samples. Analyst 2002;127:1069-75. [PMID: 12195948 DOI: 10.1039/b201173e] [Citation(s) in RCA: 56] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
4
He ZK, Fuhrmann B, Spohn U. Calibrationless determination of creatinine and ammonia by coulometric flow titration. Anal Biochem 2000;283:166-74. [PMID: 10906237 DOI: 10.1006/abio.2000.4627] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
5
Hansen EH. Principles and applications of flow injection analysis in biosensors. J Mol Recognit 1996;9:316-25. [PMID: 9174905 DOI: 10.1002/(sici)1099-1352(199634/12)9:5/6<316::aid-jmr276>3.0.co;2-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
6
Selective flow injection procedures for the determination of nitrogen containing analytes by gasdialytic-fluorimetric detection of enzymatically generated ammonia. Anal Chim Acta 1996. [DOI: 10.1016/0003-2670(96)00004-9] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
7
Schneiderka P, Pacáková V, Stulík K, Kloudová M, Jelínková K. High-performance liquid chromatographic determination of creatinine in serum, and a correlation of the results with those of the Jaffé and enzymic methods. JOURNAL OF CHROMATOGRAPHY 1993;614:221-6. [PMID: 8314933 DOI: 10.1016/0378-4347(93)80312-r] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
8
Matuszewski W, Trojanowicz M, Meyerhoff ME, Moszczyńska A, Lange-Moroz E. Flow-injection potentiometric determination of creatinine in urine using sub-Nernstian linear response range. ELECTROANAL 1993. [DOI: 10.1002/elan.1140050204] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA