1
|
Delaunay N, Combès A, Pichon V. Immunoaffinity Extraction and Alternative Approaches for the Analysis of Toxins in Environmental, Food or Biological Matrices. Toxins (Basel) 2020; 12:toxins12120795. [PMID: 33322240 PMCID: PMC7764248 DOI: 10.3390/toxins12120795] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 12/09/2020] [Accepted: 12/11/2020] [Indexed: 12/12/2022] Open
Abstract
The evolution of instrumentation in terms of separation and detection allowed a real improvement of the sensitivity and analysis time. However, the analysis of ultra-traces of toxins in complex samples requires often a step of purification and even preconcentration before their chromatographic analysis. Therefore, immunoaffinity sorbents based on specific antibodies thus providing a molecular recognition mechanism appear as powerful tools for the selective extraction of a target molecule and its structural analogs to obtain more reliable and sensitive quantitative analysis in environmental, food or biological matrices. This review focuses on immunosorbents that have proven their efficiency in selectively extracting various types of toxins of various sizes (from small mycotoxins to large proteins) and physicochemical properties. Immunosorbents are now commercially available, and their use has been validated for numerous applications. The wide variety of samples to be analyzed, as well as extraction conditions and their impact on extraction yields, is discussed. In addition, their potential for purification and thus suppression of matrix effects, responsible for quantification problems especially in mass spectrometry, is presented. Due to their similar properties, molecularly imprinted polymers and aptamer-based sorbents that appear to be an interesting alternative to antibodies are also briefly addressed by comparing their potential with that of immunosorbents.
Collapse
Affiliation(s)
- Nathalie Delaunay
- Department of Analytical, Bioanalytical Sciences and Miniaturization (LSABM), CBI ESPCI Paris, PSL University, CNRS, 75005 Paris, France; (N.D.); (A.C.)
| | - Audrey Combès
- Department of Analytical, Bioanalytical Sciences and Miniaturization (LSABM), CBI ESPCI Paris, PSL University, CNRS, 75005 Paris, France; (N.D.); (A.C.)
| | - Valérie Pichon
- Department of Analytical, Bioanalytical Sciences and Miniaturization (LSABM), CBI ESPCI Paris, PSL University, CNRS, 75005 Paris, France; (N.D.); (A.C.)
- Department of Chemistry, Sorbonne University, 75005 Paris, France
- Correspondence:
| |
Collapse
|
2
|
Aly AA, Górecki T. Green Approaches to Sample Preparation Based on Extraction Techniques. Molecules 2020; 25:E1719. [PMID: 32283595 PMCID: PMC7180442 DOI: 10.3390/molecules25071719] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 03/25/2020] [Accepted: 03/29/2020] [Indexed: 12/11/2022] Open
Abstract
Preparing a sample for analysis is a crucial step of many analytical procedures. The goal of sample preparation is to provide a representative, homogenous sample that is free of interferences and compatible with the intended analytical method. Green approaches to sample preparation require that the consumption of hazardous organic solvents and energy be minimized or even eliminated in the analytical process. While no sample preparation is clearly the most environmentally friendly approach, complete elimination of this step is not always practical. In such cases, the extraction techniques which use low amounts of solvents or no solvents are considered ideal alternatives. This paper presents an overview of green extraction procedures and sample preparation methodologies, briefly introduces their theoretical principles, and describes the recent developments in food, pharmaceutical, environmental and bioanalytical chemistry applications.
Collapse
Affiliation(s)
- Alshymaa A. Aly
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada;
- Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Menia Governorate 61519, Egypt
| | - Tadeusz Górecki
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada;
| |
Collapse
|
3
|
Yu H, Clark KD, Anderson JL. Rapid and sensitive analysis of microcystins using ionic liquid-based in situ dispersive liquid–liquid microextraction. J Chromatogr A 2015; 1406:10-8. [DOI: 10.1016/j.chroma.2015.05.075] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Revised: 05/22/2015] [Accepted: 05/30/2015] [Indexed: 11/25/2022]
|
4
|
Kaloudis T, Zervou SK, Tsimeli K, Triantis TM, Fotiou T, Hiskia A. Determination of microcystins and nodularin (cyanobacterial toxins) in water by LC-MS/MS. Monitoring of Lake Marathonas, a water reservoir of Athens, Greece. JOURNAL OF HAZARDOUS MATERIALS 2013; 263 Pt 1:105-115. [PMID: 23958137 DOI: 10.1016/j.jhazmat.2013.07.036] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Revised: 07/04/2013] [Accepted: 07/17/2013] [Indexed: 06/02/2023]
Abstract
A method for the determination of the hepatotoxic cyanotoxins microcystins (MCs, i.e. MC-LR, MC-RR, MC-YR, MC-LA) and nodularin (NOD) in water was developed using liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (LC-ESI-MS/MS) after solid phase extraction (SPE). New patterns of fragmentation of MC-LA were observed under the experimental conditions used. The method was fully validated to meet accreditation criteria. Mean recoveries at three concentration levels (0.006, 0.1 and 1 μg L(-1)) ranged between 70 and 114% with %RSD values generally below 20%. Detection limits were 2 ng L(-1) for all hepatotoxins. The method was applied to study the occurrence of MCs and NOD in Lake Marathonas, a water reservoir of Athens, over a period from July 2007 to December 2010. The protein phosphatase inhibition assay (PPIA) was additionally used for fast screening of samples. MC-YR, MC-LR and MC-RR were detected and found to vary seasonally with consistent peaks during early autumn, having maximum concentrations of 717, 451 and 174 ng L(-1), respectively. The results of this study constitute the first report on the presence, concentration levels and seasonal variations of MCs in Lake Marathonas. None of the target cyanotoxins were detected in treated drinking water samples during the period of the study.
Collapse
Affiliation(s)
- Triantafyllos Kaloudis
- Quality Control Department, Athens Water Supply and Sewerage Company (EYDAP SA), Oropou 156, 11146 Galatsi, Athens, Greece
| | | | | | | | | | | |
Collapse
|
5
|
Determination of 7 microcystins in Spirulina health food products by ultra performance liquid chromatography-tandem mass spectrometry. Se Pu 2013; 30:584-9. [DOI: 10.3724/sp.j.1123.2012.01018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
6
|
Gomes LNL, Oliveira SMAC, Giani A, von Sperling E. Association between biotic and abiotic parameters and the occurrence of cyanobacteria in a Brazilian reservoir. ENVIRONMENTAL MONITORING AND ASSESSMENT 2012; 184:4635-4645. [PMID: 21887480 DOI: 10.1007/s10661-011-2291-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2011] [Accepted: 08/15/2011] [Indexed: 05/31/2023]
Abstract
The water reservoir of Vargem das Flores, Brazil, has been subject to eutrophication problems. The occurrence of cyanobacterial blooms in this water body has raised concerns regarding the presence of toxic metabolites. In order to understand the factors that promote the proliferation and distribution of cyanobacteria in the reservoir, physicochemical parameters, species composition, and toxicity of the reservoir water column were analyzed at monthly intervals over a 3-year period (2004-2007) using a range of analytical techniques. The results showed that cyanobacteria were absent in the dry period, returning after the onset of stratification. A succession pattern was observed within this group. The Aphanocapsa genus was dominant in the last rainy period of the study (October 2006 to March 2007). However toxicity was only detected when the genera Microcystis and Sphaerocavum were present (October 2005). The principal components analysis showed negative correlation between cyanobacteria and orthophosphate. The change of dominant cyanobacteria along the 3 years of study and the final prevalence of nontoxic genera in the reservoir is an evidence of water quality improvement in response to the management techniques implemented in the reservoir basin.
Collapse
Affiliation(s)
- Lenora Nunes Ludolf Gomes
- Department of Civil and Environmental Engineering, University of Brasília, Brasília 70910-900, Brazil.
| | | | | | | |
Collapse
|
7
|
Cruz AADL, Lynch TJ, Dionysiou DD. The Effects of Sample Matrices on Immunoassays to Detect Microcystin-LR in Water. ACTA ACUST UNITED AC 2012. [DOI: 10.4236/jep.2012.310145] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
8
|
Kyprianou D, Guerreiro AR, Chianella I, Piletska EV, Fowler SA, Karim K, Whitcombe MJ, Turner AP, Piletsky SA. New reactive polymer for protein immobilisation on sensor surfaces. Biosens Bioelectron 2009; 24:1365-71. [DOI: 10.1016/j.bios.2008.07.070] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2008] [Revised: 07/23/2008] [Accepted: 07/31/2008] [Indexed: 11/25/2022]
|
9
|
Cyanotoxins: sampling, sample processing and toxin uptake. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2008; 619:483-99. [PMID: 18461780 DOI: 10.1007/978-0-387-75865-7_21] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
|
10
|
Sheng J, He M, Yu S, Shi H, Qian Y. Microcystin-LR detection based on indirect competitive enzyme-linked immunosorbent assay. ACTA ACUST UNITED AC 2007. [DOI: 10.1007/s11783-007-0056-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
Nelson MA, Papastavros E, Dodlinger M, Hage DS. Environmental analysis by on-line immunoextraction and reversed-phase liquid chromatography: optimization of the immunoextraction/RPLC interface. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2007; 55:3788-97. [PMID: 17455948 PMCID: PMC2658880 DOI: 10.1021/jf063286l] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The use of antibodies in HPLC columns for on-line immunoextraction combined with reversed-phase liquid chromatography (RPLC) is of growing interest in environmental and agricultural analysis. This technique is typically performed by using a small RPLC precolumn to capture and concentrate analytes as they elute from the immunoextraction column; however, there is little information on the conditions required for optimizing this interface. This study examined the behavior of this interface by using 2,4-dichlorophenoxyacetic acid (2,4-D) and related herbicides as model analytes. It was found that analyte dissociation from immunoextraction columns followed first-order decay and that the elution of these analytes through the immunoextraction/RPLC interface gave an exponentially modified Gaussian profile. Computer simulations were used to see how analyte elution through the interface changed with different dissociation and retention conditions. Several guidelines were developed from this work that could be used for developing and optimizing on-line immunoextraction/RPLC systems for other chemicals of environmental or agricultural interest.
Collapse
Affiliation(s)
| | | | | | - David S. Hage
- Author to whom correspondence should be addressed: Email, ; Phone, 1−(402)−472−2744; FAX, 1−(402)−472−9402
| |
Collapse
|
12
|
Allis O, Dauphard J, Hamilton B, Shuilleabhain AN, Lehane M, James KJ, Furey A. Liquid Chromatography−Tandem Mass Spectrometry Application, for the Determination of Extracellular Hepatotoxins in Irish Lake and Drinking Waters. Anal Chem 2007; 79:3436-47. [PMID: 17402708 DOI: 10.1021/ac062088q] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A novel method for the determination of hepatotoxins; microcystins (MCs), and nodularin (Nod) in lake water and domestic chlorinated tap water has been developed using liquid chromatography hyphenated with electrospray ionization triple quadrupole mass spectrometry (LC-ESI-MS/MS). Optimization of the mass spectrometer parameters and mobile-phase composition was performed to maximize the sensitivity and reproducibility of the method. Detection of the hepatotoxins was carried out using multiple reaction monitoring experiments, thus improving the selectivity of the method. A total ion chromatogram and a precursor ion scan on ion m/z 135 was also applied to all samples to detect unknown microcystins or microcystins for which there are no standards available. A comprehensive validation of the LC-ESI-MS/MS method was completed that took into account matrix effects, specificity, linearity, accuracy, and precision. Good linear calibrations were obtained for MC-LR (1-200 microg/L; R2=0.9994) in spiked lake and tap water samples (1-50 microg/L; R2=0.9974). Acceptable interday repeatability was achieved for MC-LR in lake water with RSD values (n=9) ranging from 9.9 (10 microg/L) to 5.1% (100 microg/L). Excellent limits of detection (LOD) and limits of quantitation (LOQ) were achieved with spiked MCs and Nod samples; LOD=0.27 microg/L and LOQ=0.90 microg/L for MC-LR in the "normal linear range" and LOD=0.08 microg/L and LOQ=0.25 microg/L in the "low linear range" in both lake and chlorinated tap water. Similar results were obtained for a suite of microcystins and nodularin. This sensitive and rapid method does not require any sample preconcentration, including the elimination of solid-phase extraction (SPE) for the effective screening of hepatotoxins in water below the 1 microg/L WHO provisional guideline limit for MC-LR. Furthermore, SPE techniques are time-consuming, nonreproducible at trace levels, and offer poor recoveries with chlorinated water. The application of this LC-ESI-MS/MS method for routine screening of hepatotoxins in lake and chlorinated tap water (average Cl2=0.23 mg/L) is achieved and this study represents the first direct method for the screening of hepatotoxins in chlorinated tap water.
Collapse
Affiliation(s)
- Orla Allis
- PROTEOBIO, Mass Spectrometry Centre for Proteomics and Biotoxin Research, Cork Institute of Technology, Bishopstown, Cork, Ireland
| | | | | | | | | | | | | |
Collapse
|
13
|
Sheng JW, He M, Shi HC, Qian Y. A comprehensive immunoassay for the detection of microcystins in waters based on polyclonal antibodies. Anal Chim Acta 2006; 572:309-15. [PMID: 17723494 DOI: 10.1016/j.aca.2006.05.040] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2006] [Revised: 05/11/2006] [Accepted: 05/12/2006] [Indexed: 11/22/2022]
Abstract
Microcystins (MCs) are a group of closely related toxic cyclic heptapeptides produced by common cyanobacteria (blue-green algae), and microcystin-leucine-arginine (MC-LR) is among the most frequent and most toxic microcystin congeners. In this study, a free amino group was introduced to MC-LR at its seventh amino acid residue with 2-mercaptoethylamine, and the product aminoethyl-MC-LR was coupled to bovine serum albumin (BSA) and horseradish peroxidise (HRP) by glutaraldehyde to be complete antigen (MC-LR-BSA) and labelled hapten (MC-LR-HRP), respectively. Polyclonal antibodies against MC-LR were generated by immunization with MC-LR-BSA. A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was established to detect the MCs in waters, which showed a good cross-reactivity with MC-LR, MC-RR, MC-YR, MC-LF, MC-LW and nodularin, and have a detection limit for MC-LR 0.12 microg L(-1), the 50% inhibition concentration (IC50) for MC-LR was 0.63+/-0.06 microg L(-1) and the quantitative detection range was from 0.17 to 2.32 microg L(-1), the analysis result of water samples showed good recovery and reliability. So the comprehensive and reliable dc-ELISA will well potentially suit for sensitive analysis for total MCs in drinking as well as resource water samples.
Collapse
Affiliation(s)
- Jian-Wu Sheng
- Environmental Simulation and Pollution Control, State Key Joint Laboratory, Department of Environmental Science and Engineering, Tsinghua University, Beijing 100084, China
| | | | | | | |
Collapse
|
14
|
Hauserová E, Swaczynová J, Dolezal K, Lenobel R, Popa I, Hajdúch M, Vydra D, Fuksová K, Strnad M. Batch immunoextraction method for efficient purification of aromatic cytokinins. J Chromatogr A 2005; 1100:116-25. [PMID: 16191431 DOI: 10.1016/j.chroma.2005.09.020] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2005] [Revised: 09/08/2005] [Accepted: 09/09/2005] [Indexed: 11/29/2022]
Abstract
A range of benzylaminopurines naturally occur in plants and exhibit high biological activity. Others have been synthesized, such as 6-(2-hydroxy-3-methoxybenzylamino)purine riboside (2OH3MeOBAPR), which has shown interesting anti-cancer activity under in vitro conditions. In order to study the biological activity of this interesting compound in more detail, a rapid and highly efficient method for its purification from complex samples (e.g. blood and plant extracts) is needed. Therefore, we prepared monoclonal antibodies against 2OH3MeOBAPR. The antibody had undetectable cross-reactivity with all natural isoprenoid cytokinins, but relatively high cross-reactivity with aromatic cytokinins as well as some synthetic di- and tri-substituted 6-benzylaminopurines and the corresponding ribosides. The antibody also showed strong responses and specificity in enzyme-linked immunoassays (ELISAs). In addition, it was used to prepare, for the first time, an immunoaffinity sorbent with high specificity and capacity for aromatic cytokinins. A batch immunoextraction method was then developed and optimized for the purification of 2OH3MeOBAPR from murine blood samples. The high efficacy and simplicity of this method (in off-line combination with HPLC-MS) for the isolation of target analytes from biological material is demonstrated in this study.
Collapse
Affiliation(s)
- Eva Hauserová
- Laboratory of Growth Regulators, Palacký University and Institute of Experimental Botany ASCR, Olomouc, Czech Republic
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Lei LM, Wu YS, Gan NQ, Song LR. An ELISA-like time-resolved fluorescence immunoassay for microcystin detection. Clin Chim Acta 2004; 348:177-80. [PMID: 15369752 DOI: 10.1016/j.cccn.2004.05.019] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2004] [Revised: 05/20/2004] [Accepted: 05/21/2004] [Indexed: 10/26/2022]
Abstract
BACKGROUND A time-resolved fluorescence immunoassay (TRFIA), based on anti-microcystin-LR (MCLR) monoclonal antibodies (MAbs) and europium-labeled antimouse IgG conjugate, was first developed for microcystin detection. METHODS Anti-MCLR MAbs were prepared by a standard method, and the attained MAbs showed a good cross reactivity with MCLR, MCRR and MCYR. The TRFIA was performed in an indirect competitive mode. The detection method of TRFIA was compared with indirect competitive enzyme-linked immunosorbent assay (ELISA) and high-performance liquid chromatography (HPLC). RESULTS The TRFIA exhibited a typical sigmoidal response for MCLR at concentrations of 0.005-50 ng/ml, with a wide quantitative range between 0.01 and 10 ng/ml, indicating the broadest detective range and the most sensitive of all the methods for microcystins (MCs) detection. Additionally, the TRFIA maintained good reliability through its quantitative range, as evidenced by low coefficients of variation (1.6-12.2%). The toxin data of algal samples assayed from TRFIA were in the same range as those with ELISA and HPLC, implying that the method was reliable and practical for the detection of MCs. CONCLUSIONS The TRFIA may offer a valuable alternative or a substitute for conventional ELISA for microcystin detection.
Collapse
Affiliation(s)
- La-Mei Lei
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, CAS, Donghu Nanlu No. 7, Wuchang, Wuhan 430072, PR China
| | | | | | | |
Collapse
|
16
|
Kubo T, Hosoya K, Watabe Y, Tanaka N, Sano T, Kaya K. Toxicity recognition of hepatotoxin, homologues of microcystin with artificial trapping devices. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART A, TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING 2004; 39:2597-2614. [PMID: 15509011 DOI: 10.1081/ese-200027015] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
A hepatotoxin produced by cyanobacteria, microcystin (MC), was chromatographically discriminated with newly prepared artificial trapping devices. MC involves up to 70 kinds of homologues, and because homologues have similar toxicity, effective removal and analysis methods have been required. As a trapping device to discriminate MC, we have developed a novel technique for preparation of the "imprinted recognition site" into the crosslinked nano-scale structure, namely "Fragment Imprinting Effect." This technique is simple, and its possible application fields are relatively broad. We have demonstrated the recognition for MC homologues through the combination of two different artificial molecular recognition devices prepared through fragment imprinting technique.
Collapse
Affiliation(s)
- Takuya Kubo
- Department of Polymer Science, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto, Japan
| | | | | | | | | | | |
Collapse
|
17
|
Tudorache M, Rak M, Wieczorek PP, Jönsson JA, Emnéus J. Immuno-SLM—a combined sample handling and analytical technique. J Immunol Methods 2004; 284:107-18. [PMID: 14736421 DOI: 10.1016/j.jim.2003.10.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Immuno-supported liquid membrane (immuno-SLM) extraction is a new technique that makes use of antibody (Ab)-antigen interactions as the "extraction force" to drive the mass transfer in a selective way. In immuno-SLM, anti-analyte (Ag) Abs are introduced into the acceptor phase of the SLM unit to trap the Ag that passes from the flowing donor through the SLM into the stagnant acceptor. The amount of immuno-extracted analyte (AbAg) is quantified by connecting the immuno-SLM unit on-line with a non-competitive heterogeneous fluorescence flow immunoassay (FFIA) that makes use of a fluorescein-labeled analyte tracer that titrates the residual excess of Ab present in the acceptor. A restricted access (RA) column is used for the separation of the two tracer fractions (Ag* and AbAg*) formed, and the eluted AbAg* fraction is measured downstream by a fluorescence detector. Factors influencing the optimum immuno-SLM extraction parameters, i.e., donor flow rate, extraction time and type of Ab, were investigated for immuno extraction of the model analyte atrazine. Immuno-SLM coupled to FFIA (immuno-SLM-FFIA) and FFIA alone were compared in terms of the assay sensitivities obtained and the sample matrix influence. The concentration at the mid-point of the calibration curve (IC(50)) was 16.0+/-1.4 and 36+/-16 microg/l, the limit of detection (LOD) was 2.0+/-1.1 and 20+/-10 microg/l, and the dynamic range was 2-100 and 20-500 microg/l atrazine for immuno-SLM-FFIA and FFIA, respectively. The matrix influence on the FFIA was significant in orange juice and surface water, whereas the influence was minor for immuno-SLM-FFIA with recoveries between 104% and 115% for 5 microg/l atrazine in tap water, orange juice and river water.
Collapse
Affiliation(s)
- Madalina Tudorache
- Department of Analytical Chemistry, Lund University, P.O. Box 124, 221 00 Lund, Sweden
| | | | | | | | | |
Collapse
|
18
|
Aranda-Rodriguez R, Kubwabo C, Benoit FM. Extraction of 15 microcystins and nodularin using immunoaffinity columns. Toxicon 2003; 42:587-99. [PMID: 14602114 DOI: 10.1016/j.toxicon.2003.08.001] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Microcystins (MCYSTs) were isolated from surface water using reusable immunoaffinity columns. Individual MCYST were determined by high performance liquid chromatography equipped with a photo-diode array detector (HPLC-PDA, 200-300 nm). Subsequent analysis of the samples by liquid chromatography-electrospray ionization mass spectrometry (LC-ESMS) provided molecular weight information, which was used to tentatively identify individual MCYST variants for which standards were not available. Results obtained using immunoaffinity columns (IAC)-HPLC-PDA were compared to those obtained using solid phase extraction (SPE) Oasis HLB-HPLC-PDA. This is the first report of the extraction of 15 microcystins and nodularin using immunoaffinity columns. Whereas previous reports demonstrates the use of IAC for four microcystins, we found that IAC selectively extracted the following microcystins: MCYST-RR, [D-Asp3]MCYST-RR, MCYST-YR, MCYST-LR, 3 MCYST-LR variants, MCYST-AR, MCYST-FR, MCYST-WR, MCYST-LA, MCYST-LA variant, the less polar microcystins such as MCYST-LF, MCYST-LW and nodularin. The IAC extracts were free of interferences which enabled better detection and identification of MCYSTs. Based on the amount loaded to the cartridges, the method detection limit was 10-14 ng when using IAC and 25 ng for SPE of each MCYST-RR, MCYST-YR and MCYST-LR. Reproducibilities expressed as relative standard deviation were 6-10% for SPE and 4-17% for IAC.
Collapse
Affiliation(s)
- Rocio Aranda-Rodriguez
- Health Canada, Health Environments and Consumer Safety Branch, Safe Environments Programme, Chemistry Research Division, Tunney's Pasture, Ottawa, Ont. KIA OL2, Canada.
| | | | | |
Collapse
|
19
|
Abstract
Immuno-based sample preparation techniques are based upon molecular recognition. Thanks to the high affinity and high selectivity of the antigen-antibody interaction, they have been shown to be a unique tool in the sampling area. Immuno-based sample preparation methods include the widely encountered immunoaffinity extraction sorbents, so-called immunosorbents, as well as membrane-baed or ultrafiltration techniques. This review describes the new developments and applications that have occurred in recent years with emphasis on (i) the antigen-antibody interactions, (ii) and their importance for the properties and use of immunosorbents, (iii) multiresidue extractions, (iv) the on-line coupling to chromatographic or electrophoretic separations, and (v) the high potential for improving MS detection. The recent use of artificial antibodies for sample pretreatment, so-called molecularly imprinted polymers, is also described.
Collapse
Affiliation(s)
- Marie-Claire Hennion
- Laboratoire Environnement et Chimie Analytique (UMR CNRS 7121) Ecole Supérieure de Physique et de Chimie Industrielles, 10 rue Vauquelin, 75231 Paris 05, France.
| | | |
Collapse
|
20
|
Affiliation(s)
- J S Metcalf
- Division of Environmental and Applied Biology, School of Life Sciences, University of Dundee, Dundee, DD1 4HN, United Kingdom
| | | |
Collapse
|
21
|
Chianella I, Lotierzo M, Piletsky SA, Tothill IE, Chen B, Karim K, Turner APF. Rational design of a polymer specific for microcystin-LR using a computational approach. Anal Chem 2002; 74:1288-93. [PMID: 11924591 DOI: 10.1021/ac010840b] [Citation(s) in RCA: 193] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A computational approach for the design of a molecularly imprinted polymer (MIP) specific for Cyanobacterial toxin microcystin-LR is presented. By using molecular modeling software, a virtual library of functional monomers was designed and screened against the target toxin, employed as a template. The monomers giving the highest binding energy were selected and used in a simulated annealing (molecular dynamics) process to investigate their interaction with the template. The stoichiometric ratio observed from the simulated annealing study was used in MIP preparation for microcystin-LR. The monomers were copolymerized with a cross-linker in the presence of the template. A control (blank) polymer was prepared under the same conditions but in the absence of template. A competitive assay with microcystin-horseradish peroxidase conjugate was optimized and used to evaluate the affinity and cross-reactivity of the polymer. The performance of the artificial receptor was compared to the performance of monoclonal and polyclonal antibodies raised against the toxin. The results indicate that imprinted polymer has affinity and sensitivity comparable to those of polyclonal antibodies (the detection limit for microcystin-LR using the MIP-based assay was found to be 0.1 microg L-1), while superior chemical and thermal stabilities were obtained. Moreover, cross-reactivity to other toxin analogues was very low for the imprinted polymer, in contrast to the results achieved for antibodies. It is anticipated that the polymer designed could be used in assays, sensors, and solid-phase extraction.
Collapse
Affiliation(s)
- Iva Chianella
- Institute of BioScience and Technology, Cranfield University, Silsoe, Bedfordshire, UK.
| | | | | | | | | | | | | |
Collapse
|
22
|
Zeck A, Weller MG, Niessner R. Multidimensional biochemical detection of microcystins in liquid chromatography. Anal Chem 2001; 73:5509-17. [PMID: 11816581 DOI: 10.1021/ac015511y] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The coupling of antibody-, receptor-, or enzyme-based inhibition assays postcolumn to chromatographic systems provides biological detectors with extraordinary high sensitivity and specificity. Three monoclonal antibodies (MC10E7, AD4G2, M8H5) directed against microcystins and protein phosphatase 1 (PP1) were used as off-line detectors for the HPLC separation of microcystins and nodularin in comparison to UV detection. For HPLC/ELISA coupling using antibody MC10E7, a detection limit of 0.04 ng microcystin-LR was achieved. The provisional guideline value for microcystin-LR (1 microg/L, WHO) could be monitored without prior sample concentration, in contrast to UV detection. Quantification of microcystin-LR and two cross-reactants was demonstrated. Furthermore, cross-reactivity or enzyme inhibition of new microcystins, only available in small amounts, can be determined by this method. Using a cyanobacterial extract, HPLC/ELISA coupling was compared to HPLC/UV and electrospray ionization mass spectrometry (ESI-TOFMS).
Collapse
Affiliation(s)
- A Zeck
- Institute of Hydrochemistry, Technical University of Munich, München, Germany
| | | | | |
Collapse
|
23
|
Cichna M, Markl P, Knopp D, Niessner R. On-line coupling of sol-gel-generated immunoaffinity columns with high-performance liquid chromatography. J Chromatogr A 2001; 919:51-8. [PMID: 11459311 DOI: 10.1016/s0021-9673(01)00798-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The paper demonstrates the possibility to use sol-gel-generated immunoaffinity columns as selective sample preparation step in on-line combination with HPLC. In the past sol-gel-generated immunoaffinity columns have only been included in off-line sample preparation schemes. Compared with conventional RP-materials on-line coupling of sol-gel-generated silica matrices with a pore structure designed to retain antibodies poses additional problems caused by their lower pressure tolerance and by the necessity to match the mobile phases not only to take into account the chromatographic properties but also the conformational stability of the antibodies. These problems have been overcome by an on-line system which can be regarded as a prototype for similar systems which exploit the selectivity of sol-gel immunoaffinity columns. The system consists of a sol-gel-generated immunoaffinity column coupled to an RP enrichment column and an analytical column. The practicality of such systems is demonstrated using the example of anti-pyrene immunoaffinity columns applied for the determination of pyrene in aqueous solutions.
Collapse
Affiliation(s)
- M Cichna
- Institute of Analytical Chemistry, University of Vienna, Austria.
| | | | | | | |
Collapse
|
24
|
Delaunay N, Pichon V, Hennion MC. Immunoaffinity solid-phase extraction for the trace-analysis of low-molecular-mass analytes in complex sample matrices. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2000; 745:15-37. [PMID: 10997702 DOI: 10.1016/s0378-4347(00)00116-x] [Citation(s) in RCA: 113] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Immunoaffinity solid-phase extraction (SPE) sorbents, so-called immunosorbents (ISs), are based upon molecular recognition using antibodies. Thanks to the high affinity and high selectivity of the antigen-antibody interaction, they allow a high degree of molecular selectivity and have shown to be a unique tool in the sample preparation area these last few years. Extraction and clean-up of complex biological and environmental aqueous samples are achieved in the same step and from large volumes when required. Their application to extracts from solid matrixes is solvent-free and more simple than any other clean-up procedure. Single analytes can be targeted, but since an antibody can also bind one or more analytes having structure similar to the one used for its preparation, ISs have been developed for targeting a single analyte and its metabolites. The cross-reactivity was also exploited for developing ISs that could selectively extract a whole class of structurally related compounds. This review describes the current technology used for the synthesis of the ISs, their properties and their field of application. The different parameters governing the antigen-antibody interactions and the solid-phase extraction process are discussed. Emphasis is given to the optimisation of the SPE sequence, especially to the desorption and regeneration steps. The importance of the capacity and its relationship with the analytes recovery and breakthrough volumes is highlighted for class-specific ISs. Multi-class-selective ISs are also presented. Validation studies are reviewed using various certified reference materials. Relevant examples, involving combination with chromatography in both off-line and on-line mode, illustrate the high selectivity provided in various complex matrixes. Miniaturisation is also described, since it allows high throughput of samples.
Collapse
Affiliation(s)
- N Delaunay
- Laboratoire Environnement et Chimie Analytique CNRS 657, Ecole Supérieure de Physique et de Chimie Industrielles, Paris, France
| | | | | |
Collapse
|