Varma PK, Vijayakumar M, Bhuvaneshwar GS, Kumar AS, Krishna N. Long-term evaluation of TTK Chitra™ heart valve prosthesis - a retrospective-prospective cohort study. Indian J Thorac Cardiovasc Surg 2023; 39:14-26. [PMID: 36531667 PMCID: PMC9735205 DOI: 10.1007/s12055-022-01437-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 10/25/2022] [Accepted: 10/28/2022] [Indexed: 12/04/2022] Open
Abstract
Purpose The TTK Chitra™ heart valve has more than 1,40,000 implantations so far, but no long-term data has been published. This study aims to provide long-term results of the valve. Methodology A cohort of 476 patients with implantations from January 2006 to December 2018 were followed up prospectively consisting of 104 aortic valve replacement (AVR), 87 double valve replacement (DVR), and 285 mitral valve replacement (MVR) patients. Total follow-up was 4079 patient-years (py) (AVR = 983, MVR = 2392, DVR = 704), being 96% complete. Results The results showed that actuarial survival at 15 years was 82.3% for AVR, 60.7% for MVR, and 52.2% for DVR. Freedom from all valve-related mortality and morbidity at 15 years was 73.8%, 64.8%, and 61.9% for AVR, MVR, and DVR, respectively. There was one instance of structural failure of valve disc leading to severe valvar regurgitation. Valve thrombosis incidence was 1 in AVR (0.1%/py), 6 in MVR (0.25%/py), and 1 in DVR (0.14%/py). Thrombo-embolic episodes occurred in 50 patients (AVR = 7 patients at 0.7%/py; MVR = 36 patients at 1.5%/py; DVR = 7 patients at 0.99%/py) and major hemorrhage (bleeding) in 24 patients (AVR = 0.61%/py; MVR = 0.5%/py; and DVR = 0.85%/py). The linearized rates of adverse events in this study were found to be lower than earlier published results. Conclusion The results highlight the continued safety and performance of the TTK Chitra™ heart valve (TTKCHV) in the long term at 15 years. Supplementary Information The online version contains supplementary material available at 10.1007/s12055-022-01437-9.
Collapse
Affiliation(s)
- Praveen Kerala Varma
- Department of Cardiovascular and Thoracic Surgery, Amrita Institute of Medical Sciences and Research Centre, Amrita Vishwa Vidyapeetham (Amrita University), Kochi, India
| | - Maniyal Vijayakumar
- Department of Cardiology, Amrita Institute of Medical Sciences and Research Centre, Amrita Vishwa Vidyapeetham (Amrita University), Kochi, India
| | | | - Adarsh Syla Kumar
- Department of Cardiovascular and Thoracic Surgery, Amrita Institute of Medical Sciences and Research Centre, Amrita Vishwa Vidyapeetham (Amrita University), Kochi, India
| | - Neethu Krishna
- Department of Cardiovascular and Thoracic Surgery, Amrita Institute of Medical Sciences and Research Centre, Amrita Vishwa Vidyapeetham (Amrita University), Kochi, India
| |
Collapse
|
2
|
Jamieson WRE, Ely JL, Brink J, Pennel T, Bannon P, Patel J, Gupta RK, Mohan Rao PS, Agrawal D, Wiklund L, Kappetein AP, Haaverstad R, Geisner T, Doenst T, Schlensak C, Nair S, Brown C, Siepe M, Damiano RJ, Langlois Y, Cherian KM, Azar H, Chen JC, Bavaria JE, Fedoruk LM, Munfakh NA, Sridhar V, Scholz PM, Pfeffer TA, Ye J. PROSE: Prospective Randomized Trial of the On-X Mechanical Prosthesis and the St Jude Medical Mechanical Prosthesis Evaluation: Part 2: Study results-prostheses, positions, and economic development. JTCVS OPEN 2022; 12:51-70. [PMID: 36590733 PMCID: PMC9801238 DOI: 10.1016/j.xjon.2022.07.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Revised: 06/04/2022] [Accepted: 06/23/2022] [Indexed: 01/04/2023]
Abstract
Objectives The Prospective Randomized On-X Mechanical Prosthesis Versus St Jude Medical Mechanical Prosthesis Evaluation (PROSE) trial purpose was to investigate whether a current-generation mechanical prosthesis (On-X; On-X Life Technologies/Artivion Inc) reduced the incidence of thromboembolic-related complications compared with a previous-generation mechanical prosthesis (St Jude Medical Mechanical Prosthesis; Abbott/St Jude Medical). This second report documents the valve-related complications by individual prostheses and by Western and Developing populations. Methods The PROSE trial study was conducted in 28 worldwide centers and incorporated 855 subjects randomized between 2003 and 2016. The study enrollment was discontinued on August 31, 2016. The study protocol, and analyses of 10 demographic variables and 24 risk factors were published in detail in 2021. Results The total patient population (N = 855) included patients receiving an On-X valve (n = 462) and a St Jude Medical valve (n = 393). The overall freedom evaluation showed no differences at 5 years between the prostheses for thromboembolism or for valve thrombosis. There were also no differences in mortality. There were several differences between Developing and Western populations. The freedom relations at 5 years for mortality favored Western over Developing populations. Valve thrombosis was differentiated by position and site: aortic < mitral (P = .007) and Western < Developing (P = .005). In the mitral position there were no cases in Western populations, whereas there were 8 in Developing populations (P = .217). Conclusions The On-X valve and St Jude Medical valve performed equally well in the study with no differences found. The only differentiation occurred with valve thrombosis in the mitral position more than the aortic position and occurring in Developing more than Western populations. The occurrence of valve thrombosis was also related to a younger population possibly due to anticoagulation compliance based on record review.
Collapse
Affiliation(s)
- W. R. Eric Jamieson
- Vancouver Coastal Health Research Institute, Vancouver General Hospital and St. Paul's Hospital, University of British Columbia, Vancouver, British Colombia, Canada,Address for reprints: W. R. Eric Jamieson, MD, Vancouver Coastal Health Research Institute, University of British Columbia, 272 Waterleigh Dr, Vancouver, British Columbia V5X 4T2, Canada.
| | - John L. Ely
- Heart of the Matter Clinical Consultants, Austin, Tex
| | - Johan Brink
- Division of Cardiothoracic Surgery, University of Cape Town, Cape Town, South Africa
| | - Timothy Pennel
- Division of Cardiothoracic Surgery, University of Cape Town, Cape Town, South Africa
| | - Paul Bannon
- Department of Cardiovascular Surgery, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| | - Jashvant Patel
- Department of Cardiac Surgery, B. D. Mehta Mahavir Heart Institute, Surat, India
| | - Rajiv Kumar Gupta
- Department of Cardiovascular and Thoracic Surgery, Dayanand Medical College, Ludhiana, India
| | - Prasanna Simha Mohan Rao
- Department of Cardiothoracic Surgery, Shri Jaya Deva Institute of Cardiovascular Sciences, Bangalore, India
| | - Damyanti Agrawal
- Department of Cardiovascular Surgery, Banaras Hindu University, Varanasi, India
| | - Lars Wiklund
- Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Gothenberg, Sweden
| | | | - Rune Haaverstad
- Department of Cardiothoracic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Thomas Geisner
- Department of Cardiothoracic Surgery, Universitats Klinik Jena, Jena, Germany
| | - Torsten Doenst
- Department of Cardiovascular and Thoracic Surgery, Universitats Klinik Tuebingen, Tuebingen, Germany
| | - Christian Schlensak
- Department of Cardiothoracic Surgery, Apollo Multispecialty Hospital, Chennai, India
| | - Salgunan Nair
- Department of Cardiovascular Surgery, Horizon New Brunswick Heart Center, Saint John, New Brunswich, Canada
| | - Craig Brown
- Department of Cardiovascular Surgery, Universitats Herzzentrum, Freiburg, Germany
| | - Matthias Siepe
- Department of Surgery, Washington University School of Medicine, St Louis, Mo
| | - Ralph J. Damiano
- Division of Cardiac Surgery, Jewish General Hospital, Montreal, Québec, Canada
| | - Yves Langlois
- Department of Cardiovascular Surgery, Frontier Lifeline Hospital, Chennai, India
| | | | - Hormoz Azar
- Department of Thoracic Surgery, Kaiser-Permanente Hospital, Honolulu, Hawaii
| | - John C. Chen
- Department of Surgery, Christian Hospital Northeast, St Louis, Mo
| | - Joseph E. Bavaria
- Division of Cardiovascular Surgery, University of Pennsylvania, Philadelphia, Pa
| | - Lynn M. Fedoruk
- Division of Cardiac Surgery, Victoria Heart Institute, Victoria, British Columbia, Canada
| | - Nabil A. Munfakh
- Department of Cardiothoracic and Vascular Surgery, Apollo Multispecialty Hospital, Madurai, India
| | - V. Sridhar
- Department of Surgery, Robert Wood Johnson Medical School, New Brunswick, NJ
| | - Peter M. Scholz
- Department of Surgery, Robert Wood Johnson Medical School, New Brunswick, NJ
| | - Thomas A. Pfeffer
- Department of Thoracic Surgery, Kaiser-Permanente Hospital, Los Angeles, Calif
| | - Jian Ye
- Division of Cardiovascular Surgery, St Paul's Hospital, Vancouver, British Columbia, Canada
| |
Collapse
|
3
|
Jamieson WRE, Ely JL, Brink J, Pennel T, Bannon P, Patel J, Kumar Gupta R, Mohan Rao PS, Agrawal D, Wiklund L, Kappetein AP, Haaverstad R, Geisner T, Doenst T, Schlensak C, Nair S, Brown C, Siepe M, Damiano RJ, Langlois Y, Cherian KM, Azar H, Chen JC, Bavaria JE, Fedoruk LM, Munfakh NA, Sridhar V, Scholz PM, Pfeffer TA, Ye J. PROSE: Prospective Randomized Trial of the On-X Mechanical Prosthesis and the St Jude Medical Mechanical Prosthesis Evaluation : Part 1(Patient Dynamics): Preoperative demographics and preoperative and operative risk factors. J Cardiothorac Surg 2021; 16:323. [PMID: 34732197 PMCID: PMC8565024 DOI: 10.1186/s13019-021-01632-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Accepted: 08/05/2021] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVES The PROSE trial purpose is to investigate whether the incidence of thromboembolic-related complications is reduced with a current generation mechanical prosthesis (On-X Life Technologies/CryoLife Inc.-On-X) compared with a previous generation mechanical prosthesis (St Jude Medical-SJM). The primary purpose of the initial report is to document the preoperative demographics, and the preoperative and operative risk factors by individual prosthesis and by Western and Developing populations. METHODS The PROSE study was conducted in 28 worldwide centres and incorporated 855 subjects randomized between 2003 and 2016. The study enrollment was discontinued on August 31, 2016. The preoperative demographics incorporated age, gender, functional class, etiology, prosthetic degeneration, primary rhythm, primary valve lesion, weight, height, BSA and BMI. The preoperative and operative evaluation incorporated 24 risk factors. RESULTS The total patient population (855) incorporated On-X population (462) and the St Jude Medical population (393). There was no significant difference of any of the preoperative demographics between the On-X and SJM groups. The preoperative and operative risk factors evaluation showed there was no significant difference between the On-X and St Jude Medical populations. The preoperative and operative risk factors by valve position (aortic and mitral) also documented no differentiation. The dominant preoperative demographics of the Western world population were older age, male gender, sinus rhythm, aortic stenosis, congenital aortic lesion, and mitral regurgitation. The dominant demographics of the Developing world population were rheumatic etiology, atrial fibrillation, aortic regurgitation, mixed aortic lesions, mitral stenosis and mixed mitral lesions. The Developing world group had only one significant risk factor, congestive heart failure. The majority of the preoperative and operative risk factors were significant in the Western world population. CONCLUSIONS The preoperative demographics do not differentiate the prostheses but do differentiate the Western and Developing world populations. The preoperative and operative risk factors do not differentiate the prostheses BUT do differentiate the Western and Developing world populations.
Collapse
Affiliation(s)
- W R Eric Jamieson
- Vancouver Coastal Health Research Institute, University of British Columbia, Vancouver, Canada.
| | - John L Ely
- Heart of the Matter CV Consulting, Austin, USA
| | - Johan Brink
- University of Cape Town, Cape Town, South Africa
| | | | | | | | | | | | | | - Lars Wiklund
- Sahlgrenska University Hospital, Gothenburg, Sweden
| | | | | | | | | | | | | | - Craig Brown
- Horizon New Brunswick Heart Center, St. John, Canada
| | | | | | | | | | - Hormoz Azar
- Sentara Norfolk General Hospital, Norfolk, UK
| | | | | | | | | | - V Sridhar
- Apollo Mulitspecialty Hospitals, Madurai, India
| | - Peter M Scholz
- Robert Wood Johnson School of Medicine, New Brunswick, USA
| | | | - Jian Ye
- Vancouver Coastal Health Research Institute, University of British Columbia, Vancouver, Canada
| |
Collapse
|
4
|
Bozso SJ, Kang JJH, Basu R, Adam B, Dyck JRB, Oudit GY, Moon MC, Freed DH, Nagendran J, Nagendran J. Structural Valve Deterioration Is Linked to Increased Immune Infiltrate and Chemokine Expression. J Cardiovasc Transl Res 2020; 14:503-512. [PMID: 33089488 DOI: 10.1007/s12265-020-10080-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 10/15/2020] [Indexed: 01/04/2023]
Abstract
We aim to investigate whether structural valve deterioration (SVD) of bioprosthetic xenogenic tissue heart valves (XTHVs) is associated with increased immune cell infiltration and whether co-expression of several chemokines correlates with this increase in immune infiltrate. Explanted XTHVs from patients undergoing redo valve replacement for SVD were obtained. Immunohistochemical, microscopic, and gene expression analysis approaches were used. XTHVs (n = 37) were obtained from 32 patients (mean 67.7 years) after a mean time of 11.6 years post-implantation. Significantly increased immune cellular infiltration was observed in the explanted SVD valves for all immune cell types examined, including T cells, macrophages, B cells, neutrophils, and plasma cells, compared to non-SVD controls. Furthermore, a significantly increased chemokine gradient in explanted SVD valves accompanied immune cell infiltration. These data suggest the development of SVD is associated with a significantly increased burden of immune cellular infiltrate correlated to the induction of a chemokine gradient around the XHTV, representing chronic immune rejection.Graphical abstract Proposed interaction between innate and adaptive immunity leading to the development of structural valve deterioration in xenogenic tissue heart valves.
Collapse
Affiliation(s)
- Sabin J Bozso
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB, T6G 2R3, Canada
| | - Jimmy J H Kang
- Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, T6G 2R3, Canada
| | - Ratnadeep Basu
- Division of Cardiology, Department of Medicine, University of Alberta, Edmonton, AB, T6G 2R3, Canada
| | - Benjamin Adam
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, AB, T6G 2R3, Canada
| | - Jason R B Dyck
- Cardiovascular Research Centre, Division of Pediatrics, University of Alberta, Edmonton, AB, T6G 2R3, Canada
| | - Gavin Y Oudit
- Cardiovascular Research Centre, Division of Cardiology, University of Alberta, Edmonton, AB, T6G 2R3, Canada
| | - Michael C Moon
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB, T6G 2R3, Canada
| | - Darren H Freed
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB, T6G 2R3, Canada
| | - Jayan Nagendran
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB, T6G 2R3, Canada
| | - Jeevan Nagendran
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB, T6G 2R3, Canada.
| |
Collapse
|
5
|
Bozso SJ, White A, Kang JJH, Hong Y, Norris CM, Lakey O, MacArthur RGG, Nagendran J, Nagendran J, Moon MC. Long-term Outcomes Following Mechanical or Bioprosthetic Aortic Valve Replacement in Young Women. CJC Open 2020; 2:514-521. [PMID: 33305211 PMCID: PMC7711020 DOI: 10.1016/j.cjco.2020.06.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Accepted: 06/23/2020] [Indexed: 01/01/2023] Open
Abstract
Background Studies performed to date reporting outcomes after mechanical or bioprosthetic aortic valve replacement (AVR) have largely neglected the young female population. This study compares long-term outcomes in female patients aged < 50 years undergoing AVR with either a mechanical or bioprosthetic valve. Methods In this propensity-matched study, we compared outcomes after mechanical AVR (n = 57) and bioprosthetic AVR (n = 57) between 2004 and 2018. The primary outcome of this study is survival. Secondary outcomes include the rate of reoperation, stroke, myocardial infarction, rehospitalization for heart failure, and incidence of serious adverse events. Outcomes were measured over 15 years, with a median follow-up of 7.8 years. Results In patients receiving a mechanical AVR vs a bioprosthetic AVR, overall survival at median follow-up was equivalent, at 93%. There is a lower rate of reoperation in patients receiving a mechanical AVR vs a bioprosthetic AVR (1.8% vs 8.8%). The rate of new-onset atrial fibrillation was significantly higher in the mechanical AVR group vs the bioprosthetic AVR group (18.2% vs 7.3%). No significant difference was seen in the rate of serious adverse events. Conclusions These results provide contemporary data demonstrating equivalent long-term survival between mechanical and bioprosthetic AVR, with higher rates of new atrial fibrillation after mechanical AVR, and higher rates of reoperation after bioprosthetic AVR. These results suggest that either valve type is safe, and that preoperative assessment and counselling, as well as the follow-up, medical treatment and indications for intervention, must be a collaborative decision-making process between the clinician and the patient.
Collapse
Affiliation(s)
- Sabin J Bozso
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
| | - Abigail White
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
| | - Jimmy J H Kang
- Faculty of Medicine, University of Alberta, Edmonton, Alberta, Canada
| | - Yongzhe Hong
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
| | - Colleen M Norris
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
| | - Olivia Lakey
- Faculty of Nursing, University of Alberta, Edmonton, Alberta, Canada
| | - Roderick G G MacArthur
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
| | - Jayan Nagendran
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
| | - Jeevan Nagendran
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
| | - Michael C Moon
- Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
6
|
Bozso SJ, Kang JJH, Al‐Adra D, Hong Y, Moon MC, Freed DH, Nagendran J, Nagendran J. Outcomes following bioprosthetic valve replacement in prior non‐cardiac transplant recipients. Clin Transplant 2019; 33:e13720. [DOI: 10.1111/ctr.13720] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2019] [Revised: 08/27/2019] [Accepted: 09/18/2019] [Indexed: 01/30/2023]
Affiliation(s)
- Sabin J. Bozso
- Division of Cardiac Surgery Department of Surgery University of Alberta Edmonton Alberta Canada
| | - Jimmy J. H. Kang
- Faculty of Medicine and Dentistry University of Alberta Edmonton Alberta Canada
| | - David Al‐Adra
- Department of Surgery Division of Transplantation School of Medicine and Public Health University of Wisconsin Madison WI USA
| | - Yongzhe Hong
- Division of Cardiac Surgery Department of Surgery University of Alberta Edmonton Alberta Canada
| | - Michael C. Moon
- Division of Cardiac Surgery Department of Surgery University of Alberta Edmonton Alberta Canada
| | - Darren H. Freed
- Division of Cardiac Surgery Department of Surgery University of Alberta Edmonton Alberta Canada
- Alberta Transplant Institute Edmonton Alberta Canada
- Canadian Transplant Research Program Edmonton Alberta Canada
| | - Jayan Nagendran
- Division of Cardiac Surgery Department of Surgery University of Alberta Edmonton Alberta Canada
- Alberta Transplant Institute Edmonton Alberta Canada
- Canadian Transplant Research Program Edmonton Alberta Canada
| | - Jeevan Nagendran
- Division of Cardiac Surgery Department of Surgery University of Alberta Edmonton Alberta Canada
| |
Collapse
|
7
|
Bonetti A, Marchini M, Ortolani F. Ectopic mineralization in heart valves: new insights from in vivo and in vitro procalcific models and promising perspectives on noncalcifiable bioengineered valves. J Thorac Dis 2019; 11:2126-2143. [PMID: 31285908 DOI: 10.21037/jtd.2019.04.78] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Ectopic calcification of native and bioprosthetic heart valves represents a major public health problem causing severe morbidity and mortality worldwide. Valve procalcific degeneration is known to be caused mainly by calcium salt precipitation onto membranes of suffering non-scavenged cells and dead-cell-derived products acting as major hydroxyapatite nucleators. Although etiopathogenesis of calcification in native valves is still far from being exhaustively elucidated, it is well known that bioprosthesis mineralization may be primed by glutaraldehyde-mediated toxicity for xenografts, cryopreservation-related damage for allografts and graft immune rejection for both. Instead, mechanical valves, which are free from calcification, are extremely thrombogenic, requiring chronic anticoagulation therapies for transplanted patients. Since surgical substitution of failed valves is still the leading therapeutic option, progressive improvements in tissue engineering techniques are crucial to attain readily available valve implants with good biocompatibility, proper functionality and long-term durability in order to meet the considerable clinical demand for valve substitutes. Bioengineered valves obtained from acellular non-valvular scaffolds or decellularized native valves are proving to be a compelling alternative to mechanical and bioprosthetic valve implants, as they appear to permit repopulation by the host's own cells with associated tissue remodelling, growth and repair, besides showing less propensity to calcification and adequate hemodynamic performances. In this review, insights into valve calcification onset as revealed by in vivo and in vitro procalcific models are updated as well as advances in the field of valve bioengineering.
Collapse
|
8
|
Johnson S, Stroud MR, Kratz JM, Bradley SM, Crawford FA, Ikonomidis JS. Thirty-year experience with a bileaflet mechanical valve prosthesis. J Thorac Cardiovasc Surg 2018; 157:213-222. [PMID: 30342758 DOI: 10.1016/j.jtcvs.2018.09.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 08/30/2018] [Accepted: 09/04/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND The objective was to evaluate the long-term outcomes of the St Jude Medical (Saint Paul, Minn) mechanical valve prosthesis implantation. METHODS Since 1979, every patient receiving this prosthesis has been followed annually. RESULTS From January 1979 to December 2014, 1023 patients were accrued. Patients' ages ranged from 18 to 85 years. Aortic valve replacement was performed in 584 patients, and mitral valve replacement was performed in 439 patients. Follow-up was 95% complete. Operative mortality was 3% (17/584, aortic valve replacement) and 4% (18/439, mitral valve replacement). In patients undergoing aortic valve replacement, late actuarial survival was 62% ± 2%, 32% ± 2%, and 14% ± 3% at 10, 20, and 30 years, respectively. Thirty-year freedom from reoperation, thromboembolism, valve thrombosis, bleeding, and endocarditis was 92% ± 2%, 79% ± 3%, 96% ± 1%, 56% ± 5%, and 92% ± 2%, respectively. In patients undergoing mitral valve replacement, late actuarial survival was 64% ± 3%, 28% ± 3%, and 14% ± 3% at 10, 20, and 30 years, respectively. Thirty-year freedom from reoperation, thromboembolism, valve thrombosis, bleeding, and endocarditis was 85% ± 5%, 55% ± 6%, 99% ± 1%, 57% ± 6%, and 95% ± 2%, respectively. The incidence of bleeding was 2.5% and 2.0% per patient-year for aortic valve replacement and mitral valve replacement, respectively. The incidence of thromboembolism was 1.6% and 2.9% per patient-year for aortic valve replacement and mitral valve replacement, respectively. CONCLUSIONS Annual follow-up of all of our patients receiving a St Jude Medical mechanical valves prosthesis has allowed better identification valve-related issues and events. After 3 decades of observation with close follow-up, the St Jude Medical mechanical valve continues to be a reliable prosthesis.
Collapse
Affiliation(s)
- Scott Johnson
- Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, SC
| | - Martha R Stroud
- Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, SC
| | - John M Kratz
- Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, SC
| | - Scott M Bradley
- Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, SC
| | - Fred A Crawford
- Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, SC
| | - John S Ikonomidis
- Division of Cardiothoracic Surgery, University of North Carolina at Chapel Hill, Chapel Hill, NC.
| |
Collapse
|
9
|
Early and Mid-term Outcome of the St. Jude Medical Regent 19-mm Aortic Valve Mechanical Prosthesis. Functional and Haemodynamic Evaluation. Heart Lung Circ 2017; 27:235-247. [PMID: 28400190 DOI: 10.1016/j.hlc.2017.02.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Revised: 01/23/2017] [Accepted: 02/14/2017] [Indexed: 11/21/2022]
Abstract
BACKGROUND AND OBJECTIVES The aim of the present study is to report the early and mid-term clinical and haemodynamic results of the St Jude Medical Regent 19-mm aortic mechanical prothesis (SJMR-19). MATERIALS AND METHODS Between January 2002 and January 2012, 265 patients with aortic valve disease underwent AVR (Aortic Valve Replacement) with a SJMR-19 (St Jude Medical Regent Nr.19). There were 51 males. Mean age was 67.5±12.72years and mean body surface area (BSA) was 1.67±0.14m2. Thirty-six patients required annulus enlargement. The mean follow-up was 34.5±18.8months (range 6-60 months). All patients underwent echocardiographic examination at discharge and within 1 year after surgery. RESULTS There were 14 (5.3%) hospital deaths. Six of the hospital deaths were identified in patients undergoing reoperation, significantly higher than patients undergoing first time operation (p=0.0001). Also the postoperative mortality was significantly higher in patients undergoing annulus enlargement versus patients not requiring annulus enlargement (p=0.02). The mean transprosthesis gradient at discharge was 19±9mmHg. At 6 months follow-up the mean NYHA FC class was 1.6±0.5 significantly lower than preoperatively 2.4±0.75 (p <0.0001). The M-TPG was 15.2±6.5mmHg within 1 year after surgery. Left ventricular mass (LVM) and indexed left ventricular mass (LVMi) were significantly lower than preoperatively The actuarial survival and cumulative freedom from reoperation at 1, 2 and 3 years follow-up were 99.5%, 97.5%, 96.7% and 99.2%, 96.5%, 94.5% respectively. The cumulative actuarial free-events survival at 4 years was 92%. The Cox model identified age (p=0.015), LVEF≤35% (p=0.043), reoperation (p=0.031), combined surgery (p=0.00002), and annulus enlargement (p=0.015) as strong predictors for poor actuarial free-major events survival. CONCLUSIONS The SJMR-19 offers excellent postoperative clinical, haemodynamic outcome and LVMi reduction in patients with small aortic annulus. These data demonstrate that the modern St Jude small mechanical protheses do not influence the intermediate free-reoperation survival.
Collapse
|
10
|
Thudt M, Papadopoulos N, Monsefi N, Miskovic A, Karimian-Tabrizi A, Zierer A, Moritz A. Long-Term Results Following Pericardial Patch Augmentation for Incompetent Bicuspid Aortic Valves: A Single Center Experience. Ann Thorac Surg 2017; 103:1186-1192. [DOI: 10.1016/j.athoracsur.2016.08.082] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/15/2016] [Indexed: 11/28/2022]
|
11
|
Prifti E, Bonacchi M, Ademaj F, Giunti G, Esposito G, Baboci A, Bajraktari G, Veshti A, Demiraj A, Vanini V. Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis. J Cardiothorac Surg 2015; 10:154. [PMID: 26541289 PMCID: PMC4635601 DOI: 10.1186/s13019-015-0361-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2015] [Accepted: 10/28/2015] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND The aim of the present study is to compare the early and mid-term clinical and hemodynamic results of the aortic valve replacement (AVR) with a St Jude Medical Regent 19-mm prosthesis (SJMR-19) versus Carpentied-Edwars bovine pericardial 19-mm valve (CE-19). METHODS Between January 2002 and January 2012, 265 patients (Group I) and 58 patients (Group II) with underwent AVR with a SJMR-19 and CE-19 respectively. There were no significant differences between groups regarding the demographic and preoperative echocardiographic data. Thirty-six patients in Group I and 4 in Group II required annulus enlargement in association or not with septal myectomy. The mean follow-up was 34 ± 18.5 months (range 5-60 months). RESULTS There were 14 (5.3 %) hospital deaths in Group I versus 4 (6.8 %) in Group II (p = 0.86). The multivariate logistic regression analysis identified the LVEF ≤ 35 % (p = 0.001), combined operation (p = 0.0005), CPB (p = 0.033), age (p = 0.011), annulus enlargement (p = 0.0009), reoperation (p = 0.039) and chronic renal failure (p = 0.011) as strong predictors for early postoperative death. Within 1 year after surgery peak pulmonary artery pressure, interventricular septal and left ventricular posterior wall thickness decreased significantly in both groups. The M-TPG was 15.7 ± 6.5 mmHg in Group I versus 17 ± 7 mmHg in Group II (p = 0.19). The multivariate regression analysis revealed the annulus enlargement (p = 0.018), small EOAi (p = 0.00004), postoperative LVMi (p = 0.0001) and BSA (p = 0.019) as strong predictors for higher M-TPG. The postoperative LVMi was 119 ± 22.5 gm/m(2) in Group I and 122 ± 22 gm/m(2) in Group II (p = 0.37), significantly lower than the respective preoperative values 162.5 ± 34 gm/m(2) (Group I) and 168 ± 30 gm/m(2) (Group II). The actuarial survival and cumulative free-reoperation actuarial survival at 5 years follow-up were 96.7 and 94.5 % respectively in Group I and 97 and 91 % in Group II.. There were non significant differences between groups regarding the actuarial survival and cumulative free-reoperation survival. The Cox model identified the older age (p = 0.022), LVEF ≤ 35 % (p = 0.009), reoperation (p = 0.018), combined surgery (p = 0.00075) and annulus enlargement (p = 0.033) as strong predictors for poor actuarial free-reoperation survival. CONCLUSIONS Both the SJMR-19 and CE-19 offers excellent postoperative clinical and hemodynamic outcome in patients with small aortic annulus. The LV hypertrophy and transvalvular gradients are reduced significantly indenpendently of the employed SJMR-19 or CE-19 prosthesis. Our data support recent suggestions that small valve size does not influence intermediate free-reoperation survival. The CE-19 is an excellent alternative to SJMR-19 in old patients.
Collapse
Affiliation(s)
- Edvin Prifti
- Division of Cardiac Surgery, University Hospital Center of Tirana, Tirana, Albania
| | - Massimo Bonacchi
- Department of Cardiovascular Sciences, Policlinico Careggy, University of Florence, Florence, Italy
| | - Fadil Ademaj
- University Hospital Center of Pristina, Pristina, Kosovo.
| | - Gabriele Giunti
- Department of Cardiovascular Sciences, Policlinico Careggy, University of Florence, Florence, Italy
| | | | - Arben Baboci
- Division of Cardiac Surgery, University Hospital Center of Tirana, Tirana, Albania
| | | | - Altin Veshti
- Division of Cardiac Surgery, University Hospital Center of Tirana, Tirana, Albania
| | - Aurel Demiraj
- Division of Cardiac Surgery, University Hospital Center of Tirana, Tirana, Albania
| | - Vittorio Vanini
- Division of Cardac Surgery, Humanitas Gavazzeni Clinic, Bergamo, Italy
| |
Collapse
|
12
|
Prifti E, Bonacchi M, Baboci A, Giunti G, Esposito G, Kajo E, Nuellari E, Vanini V. Does the St. Jude Regent 17-mm Offer Better Outcomes Than the Hemodynamic Plus 17-mm Aortic Valve Mechanical Prothesis? J Card Surg 2015; 30:787-95. [PMID: 26447362 DOI: 10.1111/jocs.12637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE The aim of the present study is to report the early and mid-term clinical and hemodynamic results of a prospective trial investigating the clinical performance of the St. Jude Medical Regent 17 mm (SJMR-17) versus St. Jude Medical Hemodynamic Plus 17 mm (SJMHP-17). MATERIALS AND METHODS Between January 2000 and August 2013, 20 patients (Group I) with aortic valve (AV) stenosis underwent first time AV replacement with a SJMR-17 and nine patients (Group II) underwent AV replacement with a SJMHP-17. The mean follow-up was 58 ± 31 months. RESULTS There was one death in Group I. The end-diastolic IVS thickness and end-systolic posterior left ventricle (LV) wall thickness was reduced significantly in boths groups (p = 0.001 and p = 0.006 in Group I and p = 0.007 and p = 0.011 in Group II). The peak and mean transprosthesis gradients (P-TPG and M-TPG) were 29 ± 6.8 mmHg and 17.5 ± 4.5 mmHg in Group I, significantly lower than in Group II (55.2 ± 19.7 mmHg and 28.8 ± 7.7 mmHg). The postoperative left ventricular mass (LVM) and indexed left ventricular mass (LVMi) were reduced significantly in both groups versus the preoperative values. The postoperative LVMi was 114.5 ± 10.6 g/m(2) in Group I versus 127 ± 8 g/m(2) in Group II (p = 0.01). With dobutamine, heart rate, left ventricular ejection fraction, cardiac output, transprosthesis peak, and mean gradients increased significantly in both groups, however, the P-TPG and M-TPG were significantly higher in Group II (p = 0.026 and p = 0.022) despite a non-significant increase of the indexed effective orifice area. CONCLUSIONS The SJMR-17 can be employed with satisfactory postoperative clinical and hemodynamic outcomes in patients with small aortic annulus, especially in elderly patients offering better outcome than SJMHP-17.
Collapse
Affiliation(s)
- Edvin Prifti
- Division of Cardiac Surgery, University Hospital Center of Tirana, Albania
| | - Massimo Bonacchi
- Division of Cardiac Surgery, Policlinicco Careggi, Florence, Italy
| | - Arben Baboci
- Division of Cardiac Surgery, University Hospital Center of Tirana, Albania
| | - Gabriele Giunti
- Division of Cardiac Surgery, Policlinicco Careggi, Florence, Italy
| | | | - Efrosina Kajo
- Division of Cardiac Surgery, University Hospital Center of Tirana, Albania
| | - Edmond Nuellari
- Division of Cardiac Surgery, University Hospital Center of Tirana, Albania
| | - Vittorio Vanini
- Division of Cardiac Surgery, Humanitas Gavazzeni Clinic, Bergamo, Italy
| |
Collapse
|
13
|
Misawa Y, Muraoka A, Ohki SI, Aizawa K, Kawahito K, Saito T, Sato H, Takazawa I, Kurumisawa S, Akutsu H, Sugaya A. Fifteen-year experience with the Bicarbon heart valve prosthesis in a single center. J Cardiothorac Surg 2015; 10:89. [PMID: 26123076 PMCID: PMC4486119 DOI: 10.1186/s13019-015-0294-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2015] [Accepted: 06/19/2015] [Indexed: 11/10/2022] Open
Abstract
Background The purpose of this study was to evaluate retrospectively the clinical performance of the Bicarbon valve (Sorin Biomedica Cardio, Saluggia, Italy) implanted at our center in Japan. Methods Between January 1997 and December 2011, 415 patients in our institution were implanted with the Bicarbon valve. Nine of these recipients were excluded from the study because they had already undergone valve implantation and received a Bicarbon valve in a different position. The remaining patients were analyzed for evaluation of the postoperative clinical outcomes. Of the 406 patients (mean age 60.2 ± 11.7 years), 179 underwent aortic valve replacement (AVR), 149 mitral valve replacement (MVR), and 78 both aortic and mitral valve replacement (DVR). Results There were 10 early deaths (2.5 %: 4 in the AVR group and 6 in the MVR group). Three hundred eighty-nine patients were followed up (95.8 % completeness of follow-up) with a mean follow-up of 6.6 ± 4.2 years overall (AVR 6.8 ± 4.2, MVR, 6.7 ± 4.4, and DVR 5.7 ± 3.4 years) and a cumulative follow-up of 2661 patient-years (1214, 1001, and 446 patient-years for AVR, MVR, and DVR, respectively). Ninety-nine patients died (3.7 % per patient-year: 22 valve-related and 77 valve-unrelated deaths). Survival at 10 years was 74.1 ± 4.0 % in the AVR group, 73.7 ± 4.2 % in the MVR group, and 61.0 ± 7.9 % in the DVR group. The linearized incidence of thromboembolic complications, bleeding complications, prosthetic valve endocarditis, paravalvular leaks, and sudden death in all patients was 0.5 %, 0.5 %, 0.2 %, 0.2 %, and 0.4 % per patient-year, respectively. The incidence of valve-related complications and reoperation was 1.6 % and 0.4 %, respectively. No other valve-related complications were observed. Conclusions The Bicarbon prosthetic heart valve has shown excellent clinical results and is associated with a low incidence of valve-related complications.
Collapse
Affiliation(s)
- Yoshio Misawa
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Arata Muraoka
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Shin-ichi Ohki
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Kei Aizawa
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Koji Kawahito
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Tsutomu Saito
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Hirotaka Sato
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Ippei Takazawa
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Soki Kurumisawa
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Hirohiko Akutsu
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Akira Sugaya
- Division of Cardiovascular Surgery, Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| |
Collapse
|
14
|
Prifti E, Bonacchi M, Baboci A, Giunti G, Esposito G, Krakulli K, Ademaj F, Kajo E, Vanini V. Hemodynamics of 17-mm vs. 19-mm St. Jude Medical Regent and annulus enlargement. Asian Cardiovasc Thorac Ann 2015; 23:670-83. [PMID: 25931567 DOI: 10.1177/0218492315581574] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE We aimed to compare early and midterm clinical and hemodynamic outcomes of 17-mm vs. 19-mm St. Jude Medical Regent valves with concomitant aortic annulus enlargement. METHODS Between 1999 and 2012, 20 patients (group 1) underwent first-time aortic valve replacement with a 17-mm St. Jude Medical Regent valve, and 35 patients (group 2) had a 19-mm valve and concomitant aortic annulus enlargement. The mean follow-up was 81 ± 37 months (range 20-110 months). RESULTS There was one death in group 1 vs. 4 in group 2 (p > 0.05). The mean postoperative transprosthetic gradient was 17.5 ± 4.5 in group 1 and 17 ± 6.4 mm Hg in group 2 (p = 0.83), and 37 ± 10.7 and 32 ± 13 mm Hg, respectively, under stress (p = 0.17). Left ventricular mass and left ventricular mass index were reduced and similar in both groups. Postoperative effective orifice area index was higher in group 2 (0.85 ± 0.17 cm(2 )m(-2)) than group 1 (0.76 ± 0.2 cm(2 )m(-2); p > 0.05). A multivariate Cox model identified a 19-mm valve with aortic annulus enlargement (p = 0.032), functional class (p = 0.025), reoperation (p = 0.04), ejection fraction < 35% (p = 0.042), and combined surgery (p = 0.04) as strong predictors of poorer overall event-free survival. CONCLUSIONS The 17-mm St. Jude Medical Regent valve may be employed with satisfactory postoperative clinical and hemodynamic outcomes in patients with a small aortic annulus, as an alternative to a larger prothesis with aortic annulus enlargement.
Collapse
Affiliation(s)
- Edvin Prifti
- Division of Cardiac Surgery, University Hospital Center of Tirana, Albania
| | - Massimo Bonacchi
- Division of Cardiac Surgery, Policlinicco Careggi, Florence, Italy
| | - Arben Baboci
- Division of Cardiac Surgery, University Hospital Center of Tirana, Albania
| | - Gabriele Giunti
- Division of Cardiac Surgery, Policlinicco Careggi, Florence, Italy
| | | | - Klodian Krakulli
- Division of Cardiac Surgery, University Hospital Center of Tirana, Albania
| | - Fadil Ademaj
- Division of Cardiac Surgery, University Hospital Center of Tirana, Albania
| | - Efrosina Kajo
- Division of Cardiac Surgery, University Hospital Center of Tirana, Albania
| | - Vitttorio Vanini
- Division of Cardiac Surgery, Humanitas Gavazzeni Clinic, Bergamo, Italy
| |
Collapse
|
15
|
Holst T, Reichert J, Haldenwang P, Moustafine V, Bechtel M, Strauch J, Knipp S. Special report: 26-year durability of a bioprosthesis implanted in a 21-year-old patient. Thorac Cardiovasc Surg Rep 2015; 3:3-5. [PMID: 25798348 PMCID: PMC4360689 DOI: 10.1055/s-0034-1364323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2013] [Accepted: 12/06/2013] [Indexed: 11/17/2022] Open
Abstract
The choice of prosthetic heart valve type is largely dependent upon patient's age at implantation and on what, in his eyes, seems more pertinent: avoidance of complications associated with anticoagulation of mechanical valves or structural valve deterioration of bioprosthetic valves. Long lasting and new promising concepts such as transcatheter aortic valve implantation are promoting the use of bioprosthesis even in younger patients. However, it is up to the individual patient to decide.
Collapse
Affiliation(s)
- Torulv Holst
- Department of Thoracic and Cardiovascular Surgery, West German Heart Center Essen, University Hospital, Essen, Germany
| | - Josef Reichert
- Department of Cardiothoracic Surgery, Ruhr-University of Bochum, Bochum, Germany
| | - Peter Haldenwang
- Department of Cardiothoracic Surgery, Ruhr-University of Bochum, Bochum, Germany
| | - Vadim Moustafine
- Department of Cardiothoracic Surgery, Ruhr-University of Bochum, Bochum, Germany
| | - Matthias Bechtel
- Department of Cardiothoracic Surgery, Ruhr-University of Bochum, Bochum, Germany
| | - Justus Strauch
- Department of Cardiothoracic Surgery, Ruhr-University of Bochum, Bochum, Germany
| | - Stephan Knipp
- Department of Thoracic and Cardiovascular Surgery, West German Heart Center Essen, University Hospital, Essen, Germany
| |
Collapse
|
16
|
Wu Y, Butchart EG, Borer JS, Yoganathan A, Grunkemeier GL. Clinical evaluation of new heart valve prostheses: update of objective performance criteria. Ann Thorac Surg 2014; 98:1865-74. [PMID: 25258160 DOI: 10.1016/j.athoracsur.2014.05.006] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Revised: 05/01/2014] [Accepted: 05/05/2014] [Indexed: 11/24/2022]
Abstract
This article summarizes the long-term clinical results of the Food and Drug Administration-approved heart valves, provides current updates to the objective performance criteria (OPC) used to evaluate new heart valve prostheses, and documents the steps that the International Organization for Standardization Committee used to arrive at the updated OPC. Data were extracted from 19 Food and Drug Administration summaries of safety and effectiveness data reports (31 series) and 56 literature articles (85 series) published from 1999 to 2012. The OPC were calculated for five valve-related complications by valve type (mechanical and bioprosthetic) and valve position (aortic and mitral).
Collapse
Affiliation(s)
- YingXing Wu
- Medical Data Research Center, Providence Health and Services, Portland, Oregon.
| | - Eric G Butchart
- Department of Cardiothoracic Surgery, University Hospital of Wales, Heath Park, Cardiff, United Kingdom
| | - Jeffrey S Borer
- Division of Cardiovascular Medicine and the Howard Gilman Institute for Heart Valve Diseases, State University of New York Downstate Medical Center, Brooklyn, New York
| | - Ajit Yoganathan
- School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Gary L Grunkemeier
- Medical Data Research Center, Providence Health and Services, Portland, Oregon
| |
Collapse
|
17
|
Bouchard D, Mazine A, Stevens LM, Pellerin M, Cartier R, Demers P, Hébert Y, Perrault LP, Carrier M, Lambert J. Twenty-Year Experience With the CarboMedics Mechanical Valve Prosthesis. Ann Thorac Surg 2014; 97:816-23. [DOI: 10.1016/j.athoracsur.2013.09.098] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2013] [Revised: 09/25/2013] [Accepted: 09/30/2013] [Indexed: 10/26/2022]
|
18
|
Twenty-Year Analysis of Autologous Support of the Pulmonary Autograft in the Ross Procedure. Ann Thorac Surg 2013; 96:823-9. [DOI: 10.1016/j.athoracsur.2013.04.019] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2013] [Revised: 04/06/2013] [Accepted: 04/10/2013] [Indexed: 10/26/2022]
|
19
|
Misfeld M, Akhyari P. Chirurgischer Aortenklappenersatz. ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE 2013. [DOI: 10.1007/s00398-012-0988-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
20
|
Skillington PD, Mokhles MM, Wilson W, Grigg L, Larobina M, O'Keefe M, Takkenberg J. Inclusion cylinder method for aortic valve replacement utilising the Ross operation in adults with predominant aortic stenosis - 99% freedom from re-operation on the aortic valve at 15 years. Glob Cardiol Sci Pract 2013; 2013:383-94. [PMID: 24749112 PMCID: PMC3991211 DOI: 10.5339/gcsp.2013.46] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2013] [Accepted: 12/07/2013] [Indexed: 11/03/2022] Open
Abstract
BACKGROUND To report our experience with the Ross operation in patients with predominant aortic stenosis (AS) using an inclusion cylinder (IC) method. METHODS Out of 324 adults undergoing a Ross operation, 204 patients of mean age of 41.3 years (limits 16-62) underwent this procedure for either AS or mixed AS and regurgitation (AS/AR) between October, 1992 and February, 2012, implanting the PA with an IC method. Clinical follow up and serial echo data for this group is 97% complete with late mortality follow up 99% complete. RESULTS There has been zero (0%) early mortality, and late survival at 15 years is 98% (96%, 100%). Only one re-operation on the aortic valve for progressive aortic regurgitation (AR) has been required with freedom from re-operation on the aortic valve at 15 years being 99% (96%, 100%). The freedom from all re-operations on the aortic and pulmonary valves at 15 years is 97% (94%, 100%). Echo analysis at the most recent study shows that 98% have nil, trivial or mild AR. Aortic root size has remained stable, shown by long-term (15 year) echo follow up. CONCLUSIONS In an experience spanning 19 years, the Ross operation used for predominant AS using the IC method described, results in 99% freedom from re-operation on the aortic valve at 15 years, better than any other tissue or mechanical valve. For adults under 65 years without significant co-morbidities who present with predominant AS, the pulmonary autograft inserted with this technique gives excellent results.
Collapse
Affiliation(s)
| | - M Mostafa Mokhles
- Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
| | - William Wilson
- Department of Cardiology Royal Melbourne Hospital, Melbourne, Australia
| | - Leeanne Grigg
- Department of Cardiology Royal Melbourne Hospital, Melbourne, Australia
| | - Marco Larobina
- Department of Cardiothoracic Surgery, Royal Melbourne Hospital, Australia
| | - Michael O'Keefe
- Department of Cardiothoracic Surgery, Royal Melbourne Hospital, Australia
| | - Johanna Takkenberg
- Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
| |
Collapse
|
21
|
Mizoguchi H, Sakaki M, Inoue K, Iwata T, Tei K, Miura T. Mid-term results of small-sized St. Jude Medical Regent prosthetic valves (21 mm or less) for small aortic annulus. Heart Vessels 2012; 28:769-74. [DOI: 10.1007/s00380-012-0306-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2012] [Accepted: 10/26/2012] [Indexed: 11/30/2022]
|
22
|
Is transthoracic minimally invasive aortic valve replacement too time-consuming for the busy cardiac surgeon? INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2012; 6:10-4. [PMID: 22437795 DOI: 10.1097/imi.0b013e31820bc462] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE : Transthoracic minimally invasive aortic valve replacement (TMI-AVR) is gaining popularity despite criticism that time from incision to the initiation of cardiopulmonary bypass (exposure time, ET), cardiopulmonary bypass time (CPBT), and cross-clamp time (XCT) is excessive. Database analysis was used to characterize these parameters and their associated learning curves. METHODS : From 2004 to 2008, 101 patients underwent TMI-AVR at a single institution. Of them, 54 were men (53%) and 47 were women (47%). Mean age was 70 years (range, 24-90 years). ET includes 6-cm incision, second intercostals anterior thoracotomy, medial transection of the third rib, opening pericardial sac, retracing pericardium with stay sutures, placing aortic arterial, and right arterial venous bypass cannulae. ET, CPBT, XCT, and operating room times were calculated. Logarithmic trend analysis established associated learning curves. RESULTS : ET steadily improved over time. ET decreased from an average of 51 minutes for the first 25 patients to 39 minutes for the most recent 25 patients. When surgeon experience reached 10 procedures, the ET trend line began to decline steadily and plateaued by 55 cases. Cross-clamp (55 ± 21 minutes), cardiopulmonary bypass (77 ± 31 minutes), and operating room times (304 ± 67 minutes) all remained constant. There were no early deaths or conversions to sternotomy. CONCLUSIONS : ET learning curve for TMI-AVR was reflected after 10 procedures with continued gradual improvement. Reliability of TMI-AVR was observed in the absence of a learning curve for XCT, CPBT, and operating room times. A sternal-sparing transthoracic approach for AVR can be performed safely, with expected operative times equivalent to sternotomy.
Collapse
|
23
|
Pathogenesis of paravalvular leakage as a complication occurring in the late phase after surgery. J Artif Organs 2011; 14:201-8. [DOI: 10.1007/s10047-011-0563-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2010] [Accepted: 03/17/2011] [Indexed: 10/18/2022]
|
24
|
Cunningham MJ, Berberian CE, Starnes VA. Is Transthoracic Minimally Invasive Aortic Valve Replacement Too Time-Consuming for the Busy Cardiac Surgeon? INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2011. [DOI: 10.1177/155698451100600102] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Mark J. Cunningham
- Department of Cardiothoracic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA USA
| | - Christopher E. Berberian
- Department of Cardiothoracic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA USA
| | - Vaughn A. Starnes
- Department of Cardiothoracic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA USA
| |
Collapse
|
25
|
Toole JM, Stroud MR, Kratz JM, Crumbley AJ, Bradley SM, Crawford FA, Ikonomidis JS. Twenty-Five Year Experience With the St. Jude Medical Mechanical Valve Prosthesis. Ann Thorac Surg 2010; 89:1402-9. [DOI: 10.1016/j.athoracsur.2010.01.045] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2009] [Revised: 01/18/2010] [Accepted: 01/20/2010] [Indexed: 10/19/2022]
|
26
|
Svennevig JL, Abdelnoor M, Nitter-Hauge S. Twenty-Five–Year Experience With the Medtronic-Hall Valve Prosthesis in the Aortic Position. Circulation 2007; 116:1795-800. [PMID: 17893279 DOI: 10.1161/circulationaha.106.677773] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background—
The Medtronic-Hall valve was developed and for the first time implanted in Oslo, Norway, in 1977. A total of 1104 patients received this valve at Rikshospitalet from 1977 to 1987. In the present study, we followed up on all 816 patients undergoing aortic valve replacement over a 25-year period.
Methods and Results—
This is a retrospective cohort analysis of 816 consecutive patients undergoing aortic valve replacement with the Medtronic-Hall valve at Rikshospitalet, Oslo, Norway, from 1977 to 1987. All patients were contacted by means of questionnaires or telephone. Data were checked against hospital databases and medical records. Date of death was verified by the Norwegian civil registry. Follow-up was 99.6% complete. Survival analysis included operative deaths as well as late deaths. Survival at 25 years was 24.9%. No mechanical failures were found. Valve thrombosis was seen in 4 patients, in 1 case combined with pannus formation. Small valves (20 mm to 21 mm) were associated with reduced survival; however, when controlled for the confounding effects of age and gender, valve size did not remain a significant risk factor. Patient-related factors were important: Older age, female gender, and the need for concomitant coronary artery bypass surgery significantly reduced survival, whereas surgery of the ascending aorta did not. Linearized rates of thromboembolic complications, warfarin-related bleeding, and endocarditis were 1.5%, 0.7%, and 0.16%/patient-year, respectively. At follow-up, 79% of the patients were in New York Heart Association classes I to II.
Conclusions—
This study confirms the excellent long-term outcome for patients with Medtronic-Hall valves in the aortic position.
Collapse
Affiliation(s)
- Jan L Svennevig
- Department of Thoracic and Cardiovascular Surgery, Rikshospitalet-Radiumhospitalet Medical Center, University of Oslo, 0027 Oslo, Norway.
| | | | | |
Collapse
|
27
|
Lehr EJ, Hermary S, McKay RT, Webb DNH, Abazari A, McGann LE, Coe JY, Korbutt GS, Ross DB. NMR Assessment of Me2SO in Decellularized Cryopreserved Aortic Valve Conduits. J Surg Res 2007; 141:60-7. [PMID: 17512545 DOI: 10.1016/j.jss.2007.03.082] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2007] [Revised: 03/13/2007] [Accepted: 03/22/2007] [Indexed: 11/22/2022]
Abstract
INTRODUCTION Decellularized cryopreserved allograft vascular tissue may provide a nonimmunogenic scaffold that is suitable for repopulation by cells from a variety of sources, conferring the potential for growth and repair. Although dimethyl sulfoxide (Me(2)SO) is generally regarded as a safe cryoprotectant, even low levels may alter function of repopulating cells. We investigated the residual concentration of Me(2)SO in the aqueous compartment of cryopreserved ovine aortic valve conduits following decellularization. MATERIALS AND METHODS Aortic valve conduits from Suffolk sheep were cryopreserved in 1.1 M (7.5% vol/vol) Me(2)SO according to the protocol of our local tissue bank. Three aortic valve conduits were decellularized in a series of hypotonic and hypertonic Tris buffers. Tissue samples were taken at regular time intervals throughout the decellularization process and equilibrated in double distilled, deionized H(2)O for 28 days. Quantitative proton nuclear magnetic resonance spectroscopy was used to determine the residual Me(2)SO concentration in the equilibration solutions from which Me(2)SO tissue concentrations were calculated. RESULTS After thawing, the mean Me(2)SO concentration in the valve conduit was 0.302 +/- 0.081 M. The decellularization process resulted in a stepwise reduction in the Me(2)SO concentration to less than 8.56 x 10(-5) +/- 9 x 10(-5) M (P = 0.02). The diffusion coefficient was 2.5 x 10(-6) cm(2)/s. CONCLUSIONS Our study demonstrates that Me(2)SO is effectively washed out of the aortic valve conduit during decellularization, resulting in a final concentration that is several orders of magnitude less than Me(2)SO concentrations reported to alter cell function.
Collapse
Affiliation(s)
- Eric J Lehr
- Department of Surgery, University of Alberta, Edmonton, Alberta, Canada.
| | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Misawa Y, Saito T, Konishi H, Oki SI, Kaminishi Y, Sakano Y, Morita H, Aizawa K. Clinical experience with the Bicarbon heart valve prosthesis. J Cardiothorac Surg 2007; 2:8. [PMID: 17254363 PMCID: PMC1794238 DOI: 10.1186/1749-8090-2-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2006] [Accepted: 01/25/2007] [Indexed: 12/14/2022] Open
Abstract
Bacground We have previously reported mid-term results of a study, which ended in January 2000, on the Bicarbon valve. The study concluded that the valve showed excellent clinical results, associated with a low incidence of valve-related complications. In the present study, the same patients were prospectively followed for an additional 5 years. Methods Forty-four patients had aortic valve replacement (AVR), 48 had mitral valve replacement (MVR), and 13 had both aortic and mitral valve replacement (DVR). The mean age of the 105 patients was 61.2 ± 11.3 years. The mean follow-up was 6.1 ± 1.9 years with a cumulative follow-up of 616 patient-years. Results There were 5 early deaths (4.7%: 4 in the AVR group and 1 in the MVR group) and 21 late deaths (3.4%/patient-year: 5 valve related deaths and 16 valve unrelated deaths). Survival at 8 years was 75.2 ± 7.0% in the AVR group, 76.6 ± 6.2% in the MVR group, and 55.4 ± 16.1% in the DVR group. The linearized incidence of thrombo-embolic complications, hemorrhagic complications, and paravalvular leaks in all patients was 0.65 ± 1.48%, 0.81 ± 1.69%, and 0.16 ± 0.54%/patient-year respectively. No other complications were observed. Conclusion The Bicarbon prosthetic heart valve has shown excellent long-term clinical results, associated with a low incidence of valve-related complications.
Collapse
Affiliation(s)
- Yoshio Misawa
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Tsutomu Saito
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Hiroaki Konishi
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Shin-ichi Oki
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Yuichiro Kaminishi
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Yasuhito Sakano
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Hideki Morita
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Kei Aizawa
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| |
Collapse
|
29
|
Baykut D, Grize L, Schindler C, Keil AS, Bernet F, Zerkowski HR. Eleven-Year Single-Center Experience with the ATS Open Pivot Bileaflet Heart Valve. Ann Thorac Surg 2006; 82:847-52. [PMID: 16928496 DOI: 10.1016/j.athoracsur.2006.04.042] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2005] [Revised: 04/10/2006] [Accepted: 04/18/2006] [Indexed: 11/26/2022]
Abstract
BACKGROUND The ATS Open Pivot Heart Valve was first introduced in 1992 and has been implanted routinely at our institution since 1993. Valve selection was based on surgeon preference. The objective of this study is to retrospectively analyze our 11-year clinical results with ATS prostheses. METHODS Between January 1993 and December 2003, 601 ATS valves (393 aortic valve replacement [AVR], 168 mitral valve replacement [MVR], 20 aortic plus mitral valve replacement [DVR]) were implanted in 581 patients (377 male, 204 female; mean age, 63.7 years; range 18 to 89). Preoperatively, 47 (8%) were New York Heart Association class I, 212 (36.5%) were class II, 267 (46%) were class III, and 55 (9.5%) were class IV. Preoperative comorbidities were coronary artery disease, 167 (29%); diabetes mellitus, 72 (12%); cerebrovascular disease, 2 (0.3%); endocarditis, 53 (9%); and atrial fibrillation, 115 (20%). RESULTS Follow-up is 99% complete. Data represent 2,500 cumulative patient-years. Mean follow-up is 4.3 +/- 2.6 years (range, 0.1 to 11.6). Overall hospital mortality is as follows: AVR, 3.8% (15 patients); MVR, 1.8% (3 patients); DVR, 10% (2 patients). Structural valve failure was not encountered. Overall survival at 10 years is AVR, 84.7% +/- 3.1%, AVR plus coronary artery bypass, 67.5% +/- 8.2%; MVR, 59.8% +/- 7.1%, MVR plus coronary artery bypass, 39% +/- 27.8%; and DVR, 74.3% +/- 10%. Freedom from valve-related death at 10 years is AVR, 99.2%; MVR, 94.6%; and DVR, 100%. Linearized rates for postoperative complications are paravalvular leak, 0.6% per patient-year; valve thrombosis, 0.04% per patient-year; thromboembolism, 1.1% per patient-year; major bleeding, 0.5% per patient-year; and de novo prosthesis endocarditis, 0.1% per patient-year. Postoperative mortality risk was significantly elevated by diabetes (p < 0.01), but not by other comorbidities. CONCLUSIONS Our 11-year experience demonstrates low rates of adverse events and valve-related complications with the ATS Open Pivot heart valve.
Collapse
Affiliation(s)
- Doan Baykut
- Division of Cardio-Thoracic Surgery, University Hospital Basel, Basel, Switzerland.
| | | | | | | | | | | |
Collapse
|
30
|
Lund O, Bland M. Risk-corrected impact of mechanical versus bioprosthetic valves on long-term mortality after aortic valve replacement. J Thorac Cardiovasc Surg 2006; 132:20-6. [PMID: 16798297 DOI: 10.1016/j.jtcvs.2006.01.043] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2005] [Revised: 01/10/2006] [Accepted: 01/13/2006] [Indexed: 11/19/2022]
Abstract
OBJECTIVE Choice of a mechanical or biologic valve in aortic valve replacement remains controversial and rotates around different complications with different time-related incidence rates. Because serious complications will always "spill over" into mortality, our aim was to perform a meta-analysis on overall mortality after aortic valve replacement from series with a maximum follow-up of at least 10 years to determine the age- and risk factor-corrected impact of currently available mechanical versus stented bioprosthetic valves. METHODS Following a formal study protocol, we performed a dedicated literature search of publications during 1989 to 2004 and included articles on adult aortic valve replacement with a mechanical or stented bioprosthetic valve if age, mortality statistics, and prevalences of well-known risk factors could be extracted. We used standard and robust regression analyses of the case series data with valve type as a fixed variable. RESULTS We could include 32 articles with 15 mechanical and 23 biologic valve series totaling 17,439 patients and 101,819 patient-years. The mechanical and biologic valve series differed in regard to mean age (58 vs 69 years), mean follow-up (6.4 vs 5.3 years), coronary artery bypass grafting (16% vs 34%), endocarditis (7% vs 2%), and overall death rate (3.99 vs 6.33 %/patient-year). Mean age of the valve series was directly related to death rate with no interaction with valve type. Death rate corrected for age, New York Heart Association classes III and IV, aortic regurgitation, and coronary artery bypass grafting left valve type with no effect. Included articles that abided by current guidelines and compared a mechanical and biologic valve found no differences in rates of thromboembolism. CONCLUSION There was no difference in risk factor-corrected overall death rate between mechanical or bioprosthetic aortic valves irrespective of age. Choice of prosthetic valve should therefore not be rigorously based on age alone. Risk of bioprosthetic valve degeneration in young and middle-aged patients and in the elderly and old with a long life expectancy would be an important factor because risk of stroke may primarily be related to patient factors.
Collapse
Affiliation(s)
- Ole Lund
- Department of Health Sciences, University of York, York, United Kingdom.
| | | |
Collapse
|
31
|
Bakhtiary F, Schiemann M, Dzemali O, Wittlinger T, Doss M, Ackermann H, Moritz A, Kleine P. Stentless bioprostheses improve postoperative coronary flow more than stented prostheses after valve replacement for aortic stenosis. J Thorac Cardiovasc Surg 2006; 131:883-8. [PMID: 16580448 DOI: 10.1016/j.jtcvs.2005.10.055] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2005] [Revised: 10/07/2005] [Accepted: 10/20/2005] [Indexed: 10/24/2022]
Abstract
OBJECTIVE In some randomized studies, stentless aortic valves have demonstrated hemodynamic advantages in comparison with stented prostheses. The effect of more physiologic flow dynamics on coronary artery flow has not been investigated yet. This study compares coronary perfusion after aortic valve replacement with stented or stentless porcine bioprostheses in a prospective randomized study. METHODS A total of 24 patients (73 +/- 6 years) referred for treatment of aortic stenosis were randomized to aortic valve replacement with stented (Medtronic Mosaic; (Medtronic Inc, Minneapolis, Minn) or stentless (Medtronic Freestyle; Medtronic Inc) prostheses. Coronary flow was measured by means of magnetic resonance imaging preoperatively, 5 days after the operation, and 6 months postoperatively, then with evaluation of coronary flow reserve. Echocardiography was performed to quantify transvalvular gradients and left ventricular mass regression. RESULTS Coronary flow increased in both groups significantly (P < .001) after aortic valve replacement. This increase was higher in the stentless group compared with that seen in the stented group (343 +/- 137 vs 221 +/- 66 mL/min). Also, coronary flow reserve was higher for stentless valves (3.4 +/- 0.3 for stentless valves and 2.3 +/- 0.1 for stented valves). Mean pressure gradients for Freestyle valves were lower (10 +/- 4 and 8 +/- 3 mm Hg, respectively, vs 19 +/- 6 postoperatively and 15 +/- 4 mm Hg at follow-up for Mosaic valves, P < .05). Left ventricular mass regression was similar in both groups. CONCLUSIONS Normalization of coronary artery flow after aortic valve replacement for aortic stenosis was more pronounced for stentless valves compared with stented valves. The fact that the stentless design also demonstrated a superior hemodynamic performance with lower pressure gradients might be explained by the design being closer to physiologic anatomy and thus the presence of lower turbulence levels in the sinuses of Valsalva.
Collapse
Affiliation(s)
- Farhad Bakhtiary
- Department of Thoracic and Cardiovascular Surgery, Johann Wolfgang Goethe University Hospital, Frankfurt/Main, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
32
|
Josa M, Castellá M, Paré C, Bedini JL, Cartañá R, Mestres CA, Pomar JL, Mulet J. Hemolysis in Mechanical Bileaflet Prostheses: Experience With the Bicarbon Valve. Ann Thorac Surg 2006; 81:1291-6. [PMID: 16564260 DOI: 10.1016/j.athoracsur.2005.09.045] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2005] [Revised: 09/16/2005] [Accepted: 09/21/2005] [Indexed: 10/24/2022]
Abstract
BACKGROUND Normal functioning mechanical heart valve prostheses are designed to have a certain degree of intrinsic structural regurgitation as a washout mechanism to avoid prosthetic thrombosis. However, intrinsic regurgitation leads to blood cell trauma and hemolysis. Information on hemolysis associated with mechanical bileaflet prostheses is scarce. This study evaluated factors influencing hemolysis in 197 Bicarbon mechanical bileaflet prostheses implanted in 164 patients. METHODS Serial office interviews, laboratory studies, and echocardiography evaluations were done in the surviving patients. An assay for measuring lactate dehydrogenase activity was developed, and the presence and severity of subclinical hemolysis was determined using reported criteria and analyzed at 1 and 2 years. RESULTS Hospital mortality was 5.5%. Follow-up was 98.1% complete. No patient had clinically significant or severe subclinical hemolysis. Serum lactate dehydrogenase levels were significantly higher when a paravalvular leak was documented (282 +/- 85 U/L versus 242 +/- 64 U/L; p = 0.0026). Subclinical hemolysis was significantly more frequent after mitral valve (p = 0.001) and double valve replacement (p = 0.001) than after aortic valve replacement, and was unrelated to prosthetic size or to geometric area index, even in those cases with effective orifice area index equal to or less than 0.85 cm2/m2 (p = 0.298). CONCLUSIONS Mild subclinical hemolysis is frequently associated with normal functioning Bicarbon heart valves. Subclinical hemolysis was significantly influenced by valve position but not by valve size or effective orifice area index and remained stable through time. The magnitude of hemolysis in Bicarbon prostheses compared favorably with that reported for other bileaflet heart valve prostheses.
Collapse
Affiliation(s)
- Miguel Josa
- Cardiovascular Service, Hospital Clinic and University of Barcelona, Barcelona, Spain.
| | | | | | | | | | | | | | | |
Collapse
|
33
|
Lund O, Dørup I, Emmertsen K, Jensen FT, Flø C. Hemodynamic function of the standard St. Jude bileaflet disc valve has no clinical impact 10 years after aortic valve replacement. SCAND CARDIOVASC J 2005; 39:237-43. [PMID: 16118072 DOI: 10.1080/14017430510035880] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
OBJECTIVES Size mismatch and impaired left ventricular function have been shown to determine the hemodynamic function of the standard St. Jude bileaflet disc valve early after aortic valve replacement (AVR). We aimed to analyse St. Jude valve hemodynamic function and its clinical impact in the survivors of a prospective series 10 years after AVR for aortic stenosis. DESIGN Forty-three survivors aged 32-90 years from a prospective series attended a follow-up study with Doppler echo and radionuclide cardiography 10 years after AVR for aortic stenosis. Six patients with significant left sided valve regurgitation were excluded from further analysis: they had significantly lower St. Jude valve gradient and left ventricular ejection fraction (LVEF) and larger mass index (LVMi) than 37 without. RESULTS In the 37 patients without left sided valve regurgitation peak and mean gradients were inversely related to St. Jude valve geometric orifice area (GOA) indexed for either body surface area or left ventricular end-diastolic dimension (LVEDD). The gradients correlated directly with LVEDD but not with LVEF or LVMi. Eleven patients with hypertension had higher peak gradients (31+/-13 versus 22+/-8 mmHg, p<0.05), lower LVEF, and higher LVEDD and LVMi than 26 without. Peak gradient was greater than 35 mmHg in five hypertensive patients with normal LVEF but lesser than 30 mmHg in six with impaired LVEF. Supranormal LVEF and severe size mismatch identified the remaining patients (N=3) with peak gradient above 35 mmHg. In a multilinear regression analysis GOA indexed for LVEDD, hypertension, and LVEF were independently related to peak gradient. CONCLUSION High gradients of the standard St. Jude bileaflet disc valve 10 years after AVR was primarily related to systemic hypertension and mismatch between valve and left ventricular cavity size. Hypertension and left sided valve regurgitation, but not St. Jude valve gradient or size mismatch, were the dominant determinants of left ventricular hypertrophy and impaired function.
Collapse
Affiliation(s)
- Ole Lund
- Department of Cardiothoracic Surgery, Aarhus University Hospital in Skejby, Aarhus, Denmark.
| | | | | | | | | |
Collapse
|
34
|
Emery RW, Krogh CC, Arom KV, Emery AM, Benyo-Albrecht K, Joyce LD, Nicoloff DM. The St. Jude Medical Cardiac Valve Prosthesis: A 25-Year Experience With Single Valve Replacement. Ann Thorac Surg 2005; 79:776-82; discussion 782-3. [PMID: 15734375 DOI: 10.1016/j.athoracsur.2004.08.047] [Citation(s) in RCA: 114] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/23/2004] [Indexed: 11/16/2022]
Abstract
BACKGROUND From October 1977 to October 2002, 4,480 patients (age range, 17 to 94 years; average, 64 +/- 13 years) underwent single valve replacement with the St. Jude Medical heart valve. Of 2,982 aortic (AVR) and 1,498 mitral valve replacements (MVR), concomitant coronary artery bypass grafting was performed on 42% and 33%, respectively. METHODS Cardiac Surgical Associates has maintained an independent database of patients having valve replacement with the St. Jude Medical prosthesis since the world's first implant. Patients were contacted by questionnaire or phone from November 2002 through June 2003. Hospital course and valve-related events were verified by patient chart review or physician contact. RESULTS Follow-up was 95% complete. Operative mortality was 4% with AVR and 9% with MVR. Total follow-up was 32,190 patient-years (range, 1 month to 24.8 years; average, 7 +/- 5 years). During the study period, patient freedom from late mortality was 61% (AVR, 61%; MVR, 63%), and from valve-related mortality 92% (AVR, 93%; MVR, 91%). Freedom from thromboembolic events was 85% (86% AVR, 81% MVR), from bleeding events, 81% (81% AVR, 81% MVR), from reoperation, 98% (99% AVR, 97% MVR), from endocarditis, 98% (99% AVR, 98% MVR), and from valve thrombosis, 99% (99% AVR, 98% MVR). There was one MVR structural failure (0.06%). CONCLUSIONS The St. Jude Medical valve has proven to be an effective and durable valve prosthesis with a low event rate during the long term.
Collapse
Affiliation(s)
- Robert W Emery
- Cardiac Surgical Associates, PA, St. Paul, Minnesota 55114, USA.
| | | | | | | | | | | | | |
Collapse
|
35
|
Misawa Y, Taguchi M, Aizawa K, Takahashi H, Sakano Y, Kaminishi Y, Oki SI, Konishi H, Saito T, Kato M. Twenty-Two Year Experience with the Omniscience Prosthetic Heart Valve. ASAIO J 2004; 50:606-10. [PMID: 15672796 DOI: 10.1097/01.mat.0000144366.11737.f0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
This study was designed to evaluate the long-term clinical results of the Omniscience tilting disc valve. Omniscience valves were implanted in 51 patients (mean age, 50 +/- 10 years); 18 had aortic valve, 24 had mitral valve, and 9 had both aortic and mitral valve replacements. Oral warfarin potassium and dipyridamole were prescribed as our anticoagulant therapy. Preoperatively, 42 patients were in New York Heart Association class III or IV, and 23 of 25 surviving patients were in class I or II after operation. There were 2 (3.9%) early deaths and 23 late deaths (3.5 +/- 0.7% per patient-year). Cardiac related mortality including congestive heart failure, sudden death, and thromboembolism, and hemorrhagic complications were seen in 16 patients. Overall survival at 10, 15, and 20 years was 77 +/- 6%, 62 +/- 7%, and 46 +/- 7%, respectively. Thromboembolic complications were seen in 5 patients, for a rate of 0.8 +/- 0.3% per patient-year; similarly, hemorrhagic complications were also seen in 5 patients. Nonstructural prosthetic valve dysfunction was seen in 4 patients, for a rate of 0.6 +/- 0.3% per patient-year, and sudden death was seen in 2, a rate of 0.3 +/- 0.2% per patient-year. The Omniscience prosthesis demonstrated excellent postoperative clinical status with low rates of valve related complications.
Collapse
Affiliation(s)
- Yoshio Misawa
- Division of Cardiovascular Surgery, Jichi Medical School, Tochigi, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Puvimanasinghe JPA, Takkenberg JJM, Edwards MB, Eijkemans MJC, Steyerberg EW, Van Herwerden LA, Taylor KM, Grunkemeier GL, Habbema JDF, Bogers AJJC. Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation. Heart 2004; 90:1172-8. [PMID: 15367517 PMCID: PMC1768482 DOI: 10.1136/hrt.2003.013102] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND Mechanical valves and bioprostheses are widely used for aortic valve replacement. Though previous randomised studies indicate that there is no important difference in outcome after implantation with either type of valve, knowledge of outcomes after aortic valve replacement is incomplete. OBJECTIVE To predict age and sex specific outcomes of patients after aortic valve replacement with bileaflet mechanical valves and stented porcine bioprostheses, and to provide evidence based support for the choice of prosthesis. METHODS Meta-analysis of published results of primary aortic valve replacement with bileaflet mechanical prostheses (nine reports, 4274 patients, and 25,726 patient-years) and stented porcine bioprostheses (13 reports, 9007 patients, and 54,151 patient-years) was used to estimate the annual risks of postoperative valve related events and their outcomes. These estimates were entered into a microsimulation model, which was employed to calculate age and sex specific outcomes after aortic valve replacement. RESULTS Life expectancy (LE) and event-free life expectancy (EFLE) for a 65 year old man after implantation with a mechanical valve or a bioprosthesis were 10.4 and 10.7 years and 7.7 and 8.4 years, respectively. The lifetime risk of at least one valve related event for a mechanical valve was 48%, and for a bioprosthesis, 44%. For LE and EFLE, the age crossover point between the two valve types was 59 and 60 years, respectively. CONCLUSIONS Meta-analysis based microsimulation provides insight into the long term outcome after aortic valve replacement and suggests that the currently recommended age threshold for implanting a bioprosthesis could be lowered further.
Collapse
Affiliation(s)
- J P A Puvimanasinghe
- Department of Cardiothoracic Surgery, Room Bd 162a, Erasmus MC, Rotterdam, Netherlands.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
|
38
|
Ikonomidis JS, Kratz JM, Crumbley AJ, Stroud MR, Bradley SM, Sade RM, Crawford FA. Twenty-year experience with the St Jude Medical mechanical valve prosthesis. J Thorac Cardiovasc Surg 2004; 126:2022-31. [PMID: 14688722 DOI: 10.1016/j.jtcvs.2003.07.005] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND We have prospectively followed all adult St Jude Medical mechanical valve recipients at the Medical University of South Carolina since the initial implant in January 1979 and now present our 20-year experience. METHODS We prospectively followed 837 valve recipients (aortic valve replacement; n = 478; mitral valve replacement; n = 359) from January 1979 to December 2000 at 12-month intervals. RESULTS Ages ranged from 19 to 84 years. Follow-up averaged (mean +/- standard deviation) 7 +/- 5 years (98% complete). Patients were in New York Heart Association class III or IV in 77% (aortic valve replacement) and 89% (mitral valve replacement) preoperatively. A 19-mm valve was implanted in 15.5% of aortic valve replacement patients. Coronary bypass was required in 31% of aortic valve replacements and 20% of mitral valve replacements. Operative mortality was 17/478 (3.6%) in aortic valve replacement and 19/359 (5.3%) in mitral valve replacement, and multivariable predictors were 19-mm valve size, 3 or more coronary bypass grafts, and New York Heart Association class IV for aortic valve replacement and New York Heart Association class IV and age for mitral valve replacement. Actuarial survivorship at 10 and 20 years was 57% +/- 3% and 26% +/- 5% for aortic valve replacement and 61% +/- 3% and 39% +/- 4% for mitral valve replacement. Multivariable predictors of late death were African-American ethnicity, New York Heart Association class III or IV, coronary bypass, and age for aortic valve replacement and New York Heart Association class III or IV, coronary bypass, and age for mitral valve replacement. For aortic valve replacement, effective orifice area was univariately (P =.002) but not multivariately (P =.378) predictive of late death. Structural valve deterioration was not observed. For aortic valve replacement, actuarial freedom (at 10 and 20 years) from reoperation was 93% +/- 1% and 90% +/- 2%; thromboembolism, 82% +/- 3% and 68% +/- 8%; bleeding events, 77% +/- 3% and 66% +/- 6%; prosthetic valve endocarditis, 94% +/- 1% and 94% +/- 1%; valve-related mortality, 94% +/- 2% and 86% +/- 4%; and valve-related mortality or morbidity, 58% +/- 3% and 32% +/- 8%. For mitral valve replacement, actuarial freedom (at 10 and 20 years) from reoperation was 96% +/- 1% and 90% +/- 3%; thromboembolism, 77% +/- 3% and 59% +/- 7%; bleeding events, 86% +/- 2% and 65% +/- 8%; prosthetic valve endocarditis, 98% +/- 1% and 96% +/- 2%; valve-related mortality, 89% +/- 0.2% and 74% +/- 8%; and valve-related mortality or morbidity, 63% +/- 3% and 29% +/- 7%. CONCLUSIONS After 2 decades of observation with close follow-up, the St Jude Medical mechanical valve continues to be a reliable prosthesis.
Collapse
Affiliation(s)
- John S Ikonomidis
- Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston 29464, USA.
| | | | | | | | | | | | | |
Collapse
|
39
|
Misawa Y, Saito T, Konishi H, Oki SI, Kaminishi Y, Takahashi H, Aizawa K, Kamisawa O, Kato M, Fuse K. When and how does nonstructural mechanical prosthetic heart valve dysfunction occur? Gen Thorac Cardiovasc Surg 2003; 51:355-60. [PMID: 12962412 DOI: 10.1007/bf02719467] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVE We discuss the clinical aspects related to mechanical valve dysfunction based upon 20 years' experience of our cases. METHODS Between January 1982 and December 2001, 21 patients underwent surgical interventions because of mechanical valve dysfunction. Thirteen men and 8 women (mean age 47 +/- 20, range 3-75 years-old), were included. RESULTS Mitral valve dysfunction was observed in 12 patients. Prosthetic valve stenosis occurred in 6 patients between 2 and 224 months, and paravalvular leaks in 4 between 1 and 71 months after surgery. The other 2 patients suffered from hemolytic anemia with mild paravalvular leaks between 102 and 104 months after surgery. Aortic valve dysfunction was observed in 8 patients including 3 stenotic lesions between 48 and 97 months and 5 paravalvular leaks between 3 and 150 months after surgery. Tricuspid regurgitation was seen in 1 patient with a huge right atrium at 42 months after surgery. Early death was seen in 1 patient. Late death occurred in 1 patient, 17 years after operation. Survival, including early death, was 95.2%, at 10 and 15 years. One valve-related complication of bioprosthetic valve endocarditis at the mitral and tricuspid positions occurred 12 years after a reoperation. The freedom from complications was 95.2% at 10 years, and 76.2% at 15 years. CONCLUSIONS Paravalvular leaks without overt endocarditis had latency periods of up to 12 years, and pannus formation was observed 20 years after surgery. Early and late clinical results after surgery for mechanical valve dysfunction were excellent.
Collapse
Affiliation(s)
- Yoshio Misawa
- Division of Cardiovascular Surgery, Jichi Medical School, Minami-kawachi, Tochigi, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Abstract
This review summarizes the major long-term (> or =10 to 15 years) patient outcomes after insertion of many Food and Drug Administration approved prosthetic heart valves (PHV). Mechanical PHV was associated with a better survival (p < 0.02) at 15 years after aortic valve replacement (AVR) than with a bioprosthesis in the Department of Veterans Affairs (DVA) trial. In both the DVA and the Edinburgh Heart Valve trials, bioprosthesis were associated with structural valve deterioration (SVD) (mitral valve replacement [MVR] > AVR) and, therefore, for replacement of the PHV. Thromboembolism and bleeding rate were higher with mechanical PHV. Mortality after AVR and MVR is high at 10 to 15 years because of the associated comorbid conditions and older age of patients. Outcomes with "new" good valves are similar to that with "older" good valves. Complication rates of thromboembolism, bleeding, endocarditis, and leak vary widely; the rates of these complications are not different among different mechanical PHV and among different bioprosthetic PHV. Structural valve deterioration is rare with mechanical PHV. Structural valve deterioration of bioprosthesis after MVR is higher than after AVR; after AVR, homografts and bioprosthesis have similar rates of SVD. The exact rate of SVD of the pulmonary autograft is uncertain. Valve prosthesis-patient mismatch is clinically important when it is severe and in selected patients when it is moderate. Bioprosthesis have a low rate of SVD in the older patient and, thus, are the PHV of choice for AVR in patients > or =60 to 65 years of age and for MVR in patients > or =65 to 70 years of age; in younger patients mechanical valves are the PHV of choice. In individual patients there may be exceptions to these general rules.
Collapse
Affiliation(s)
- Shahbudin H Rahimtoola
- Griffith Center, Division of Cardiovascular Medicine, Department of Medicine, LAC + USC Medical Center, Keck School of Medicine at the University of Southern California, 2025 Zonal Avenue, Los Angeles, CA 90033, USA
| |
Collapse
|
41
|
Gelsomino S, Morocutti G, Da Col P, Masullo G, Carella R, Guzzi G, Spedicato L, Livi U. Early in vivo hemodynamic results after aortic valve replacement with the St Jude Medical Regent mechanical heart valve in patients with pure aortic stenosis. J Card Surg 2003; 18:125-32. [PMID: 12757339 DOI: 10.1046/j.1540-8191.2003.02003.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND The St Jude Medical Regent is a new-generation mechanical heart valve that represents a design evolution of the St Jude Hemodynamic Plus Series (HP). The purpose of this study was to evaluate early "in vivo" hemodynamic performance of the Regent valve in patients with aortic stenosis. METHODS Between March 2000 and December 2001, 32 patients (mean age 59.9 +/- 5.9,56.3% male) with pure aortic stenosis received a Regent mechanical prosthesis in the aortic position. Hemodynamic performance was assessed by Doppler echocardiography at discharge, two months, six months, and one year by calculating peak transprosthetic velocity (Vmax), mean (MG) and peak (PG) transprosthetic gradients, effective orifice area index (EOAI), left ventricular mass index (LVMI), and degree of aortic regurgitation. RESULTS A significant reduction in mean and peak transaortic gradients (p < 0.001) and a significant increase in EOAI (p < 0.001) over time followed valve replacement, and a bivariate analysis of variance (ANOVA) failed to demonstrate statistical differences by valve size over time (p = ns). A significant reduction in left ventricular hypertrophy occurred over time (p < 0.001) in all valve sizes (p = ns between groups): baseline LVMI was 221 +/- 57 g/cm2; it decreased by 30 g/cm2 (p < 0.001) at discharge. LVMI decreased from 191 +/- 54 g/cm2 to 161 +/- 41 g/cm2 (p < 0.001) from discharge to two months. Further reductions were not significant. At the six-month follow-up no patient in our cohort exhibited moderate or severe aortic regurgitation at Doppler echocardiography. CONCLUSIONS Early results with the St Jude Medical Regent valve have been satisfactory. Further assessments are necessary to confirm these results.
Collapse
Affiliation(s)
- Sandro Gelsomino
- Department of Cardiovascular Sciences, General Hospital S. Maria Della Misericordia, Udine, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
42
|
Grunkemeier GL, Wu Y. "Our complication rates are lower than theirs": statistical critique of heart valve comparisons. J Thorac Cardiovasc Surg 2003; 125:290-300. [PMID: 12579097 DOI: 10.1067/mtc.2003.53] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVES From the widely differing complication rates published for every heart valve, is it possible to determine a true rate for each valve and to compare the rates of two different valves? We investigated this question for the two most popular bileaflet valves. METHODS Aortic valve data were abstracted from 14 St Jude Medical (St Jude Medical Inc, Minneapolis, Minn; 33,125 patient-y) and 11 Carbomedics (Sulzer Carbomedics Inc, Austin, Tex; 19,141 patient-y) series, and mitral valve data were abstracted from 11 St Jude Medical (21,553 patient-y) and 8 Carbomedics (8368 patient-y) series. Regression analysis was used to accommodate heterogeneity among rates with the same valve model, to estimate hazard ratios and 95% confidence intervals for the valve model effect, and to incorporate other series-level risk factors. RESULTS Most of the complication rates with both valve models exhibited significant heterogeneity. For thromboembolism and bleeding, the relative risks for valve model were not significantly different from unity. Valve thrombosis rates exhibited less heterogeneity: the Carbomedics valve had a lower rate in the aortic position (hazard ratio 0.2, 95% confidence interval 0.1-0.6) and a higher rate in the mitral position (hazard ratio 1.9, 95% confidence interval 1.0-3.8). CONCLUSIONS Unlike simple weighted averages of valve complication rates, regression methods can incorporate heterogeneity related to center effects and allow for inclusion of other risk factors. Thromboembolism and bleeding rates were not significantly different with St Jude Medical and Carbomedics valves. Valve thrombosis appeared to differ between the two valves, but the absolute differences in rates were small. Because of the variability among rates with the same valve, statistical comparisons must be interpreted cautiously.
Collapse
|
43
|
Misawa Y, Saito T, Konishi H, Oki SI, Kaminishi Y, Tezuka Y, Aizawa K, Takahashi H, Hasegawa N, Kamisawa O, Kato M, Fuse K. Single-center experience with the bicarbon bileaflet prosthetic heart valve in Japan. Artif Organs 2002; 26:856-61. [PMID: 12296925 DOI: 10.1046/j.1525-1594.2002.06987.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
We analyzed midterm results using the Bicarbon valve in a single center. Forty-four patients had aortic valve replacement (AVR), 48 had mitral valve replacement (MVR), and 13 had both aortic and mitral valve replacement (DVR). The mean age of the 105 patients was 61.2 +/- 11.3 years. The mean follow-up was 1.8 +/- 1.1 years with a cumulative follow-up of 188 patient-years. There were 5 early deaths (4.7%: 4 in the AVR group and 1 in the MVR group) and 5 late deaths (2.7% per patient-year: 3 malignancy, 1 cerebral hemorrhage, 1 myocardial infarction). Survival at 3 years was 91 +/- 4% in the AVR group, 92 +/- 5% in the MVR group, and 66 +/- 23% in the DVR group. The linearized incidence of thromboembolic complications, hemorrhagic complications, and paravalvular leaks in all patients was 1.06 +/- 2.34%, 1.60 +/- 2.53%, and 0.53 +/- 2.22% per patient-year, respectively. No other complications were observed. In conclusion, the Bicarbon prosthetic heart valve has shown excellent clinical results associated with a low incidence of valve-related complications.
Collapse
Affiliation(s)
- Yoshio Misawa
- Division of Cardiovascular Surgery, Jichi Medical School, Tochigi, Japan.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Misawa Y, Konishi H, Saito T, Fuse K. Paravalvular leakage causing hemolytic anemia at 8-9 years after mitral valve replacement. THE JAPANESE JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY : OFFICIAL PUBLICATION OF THE JAPANESE ASSOCIATION FOR THORACIC SURGERY = NIHON KYOBU GEKA GAKKAI ZASSHI 2002; 50:530-2. [PMID: 12561097 DOI: 10.1007/bf02913169] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We report two similar cases of women, aged 52 and 71 years, who developed shortness of breath or easy fatigability at 8-9 years after mitral valve replacement of the mitral valve in each patient, the echocardiographic study revealed paravalvular leakage. Previous examination before the appearance of symptoms had revealed a well-functioned prosthetic valve, and no hematological abnormality had been detected. The hemoglobin levels at admission were 6.4 and 6.6 g/dl, and their serum lactate dehydrogenase levels were 5218 and 4608 mU/ml. Each successfully underwent another valve replacement, and after surgery, the hemolytic anemia and the symptoms disappeared.
Collapse
Affiliation(s)
- Yoshio Misawa
- Division of Cardiovascular Surgery, Jichi Medical School, 3311-1 Yakushiji, Minami-Kawachi, Tochigi 329-0498, Japan
| | | | | | | |
Collapse
|
45
|
Affiliation(s)
- David R Clarke
- Children's Hospital and University of Colorado Health Sciences Center, Denver, 80218, USA.
| |
Collapse
|
46
|
Gelsomino S, Morocutti G, Da Col P, Frassani R, Carella R, Minen G, Livi U. Preliminary experience with the St. Jude Medical Regent mechanical heart valve in the aortic position: early in vivo hemodynamic results. Ann Thorac Surg 2002; 73:1830-6; discussion 1836. [PMID: 12078777 DOI: 10.1016/s0003-4975(01)03603-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND The St. Jude Medical Regent is a new generation mechanical aortic valve. METHODS Between March 2000 and July 2001, this valve was implanted in the aortic position in 40 patients (21 men; mean age 59.1 +/- 9.0 years). Preoperatively, 24 patients (60%) were in New York Heart Association functional class III or IV. Eighteen patients (45%) underwent associated procedures. Mean valve size was 21.4 +/- 2.4 mm. The mean duration of follow-up was 8.5 +/- 4.5 months (range, 1 to 16 months). RESULTS There were no operative deaths. Early complications included one reoperation for bleeding and one transient low output syndrome. Valve replacement was followed by a significant reduction in mean and peak transaortic gradients over time (p < 0.001) and analysis of variance failed to demonstrate statistical differences between valve size over time (p = not significant). A significant reduction in left ventricular hypertrophy occurred over time (p = 0.01) in all valve sizes (p = not significant between groups): baseline left ventricular mass index was 194 g/cm2; it reduced by 22 g/cm2 (p = 0.006) at discharge. Left ventricular mass index decreased from 172 +/- 55 g/cm2 to 156 +/- 44 g/cm2 (p = 0.03) from discharge to 2 months. Further reductions were not significant. Relative wall thickness decreased from 0.57 +/- 0.13 preoperatively to 0.42 +/- 0.06 at discharge (p = 0.001), and again at 2 months (-0.2; p = not significant), and at 1 year (-0.02; p = not significant). CONCLUSIONS The early experience with the St. Jude Medical Regent valve has been satisfactory.
Collapse
Affiliation(s)
- Sandro Gelsomino
- Department of Cardiovascular Sciences, General Hospital S. Maria Della Misericordia, Udine, Italy.
| | | | | | | | | | | | | |
Collapse
|
47
|
Anttila V, Heikkinen J, Biancari F, Oikari K, Pokela R, Lepojärvi M, Salmela E, Juvonen T. A retrospective comparative study of aortic valve replacement with St. Jude medical and medtronic-hall prostheses: a 20-year follow-up study. SCAND CARDIOVASC J 2002; 36:53-9. [PMID: 12018768 DOI: 10.1080/140174302317282393] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
OBJECTIVE To compare the long-term clinical outcome of patients who underwent aortic valve replacement with St. Jude Medical and Medtronic-Hall mechanical prostheses. DESIGN From June 1978 to June 1982, 43 Medtronic-Hall and 48 St. Jude Medical mechanical valves were implanted in 90 consecutive patients with aortic valve disease, and their clinical outcome was retrospectively assessed. RESULTS At 20 years in the St. Jude Medical group and in the Medtronic-Hall group the actuarial rates of overall survival were 50 and 49% (p = NS), of cardiovascular survival 66 and 63% (p = NS), of valve-related survival 95 and 91% (p = NS), of freedom from major valve-related complications 83 and 45% (p = 0.005), from major cerebrovascular events 93 and 71% (p =0.06), from valve thrombosis 97 and 89% (p = NS), from aortic valve reoperation 93 and 88% (p = NS), from major bleeding 96 and 82% (p = 0.04), and from endocarditis 93 and 82% (p = NS), respectively. The linearized rate of overall major aortic valve prosthesis-related complications was 3.47%/year in the Medtronic-Hall valve group and 1.53%/year in the St. Jude Medical valve group (p = 0.003). Multivariate analysis showed that the type of prosthesis was predictive of freedom from valve-related complications (p = 0.01; 2.849; C.I. 95%: 1.246-6.516). CONCLUSION The aortic St. Jude Medical mechanical valve seems to be associated with a slightly lower rate of long-term valve-related morbidity than the aortic Medtronic-Hall mechanical valve. Because of the small patient population and the retrospective nature of the study, the choice between these two prostheses should not be made only on the basis of these findings. However, these results suggest a reappraisal for further comparative studies with such an extended follow-up.
Collapse
Affiliation(s)
- Vesa Anttila
- Department of Cardio-thoracic and Vascular Surgery, University of Oulu, Finland
| | | | | | | | | | | | | | | |
Collapse
|