1
|
Takami Y, Tajima K, Kato W, Fujii K, Hibino M, Munakata H, Sakai Y. Clinical validation of coronary artery flow through an intracoronary shunt during off-pump coronary artery bypass grafting. J Thorac Cardiovasc Surg 2012; 147:259-63. [PMID: 23141031 DOI: 10.1016/j.jtcvs.2012.10.026] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2012] [Revised: 09/19/2012] [Accepted: 10/16/2012] [Indexed: 11/30/2022]
Abstract
OBJECTIVES Intracoronary shunts have been developed for a bloodless field and preserved forward flow preventing ischemia during off-pump coronary artery bypass (OPCAB) surgery. However, reports directly measuring the forward flow through the shunt in clinical settings are lacking. METHODS Using a 7.5-MHz Doppler probe, we investigated the coronary flow through a 1.5-mm shunt inserted into the left anterior descending artery (LAD) for anastomosis with the internal thoracic artery during OPCAB in 30 consecutive patients. The following Doppler flow parameters were obtained before and after shunting: peak velocity, mean velocity, time-velocity integral, and flow. RESULTS No patients developed significant electrocardiographic changes and the peak value of postoperative myocardial band of creatine kinase was 17 ± 16 IU/L. All Doppler flow parameters of the LAD decreased significantly after shunting; peal velocity: 71.3 ± 34.6 cm/second to 54.5 ± 25.3 cm/second (-24% ± 27%), mean velocity: 33.3 ± 18.3 cm/second to 26.3 ± 14.0 cm/second (-21% ± 23%), and time-velocity integral: 28.7 ± 12.1 cm to 19.0 ± 7.1 cm (-28% ± 14%), and flow: 38.7 ± 16.8 mL/minute to 25.0 ± 9.5 mL/minute (-31% ± 13%) (P < .01). CONCLUSIONS The LAD flow is preserved at least 50% through a 1.5-mm intracoronary shunt, although the flow pattern was attenuated, during OPCAB anastomosis. The Doppler evaluation of the coronary artery flow before and after shunting is useful to justify the protective use of the shunt on myocardial perfusion during OPCAB.
Collapse
Affiliation(s)
- Yoshiyuki Takami
- Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan.
| | - Kazuyoshi Tajima
- Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
| | - Wataru Kato
- Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
| | - Kei Fujii
- Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
| | - Makoto Hibino
- Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
| | - Hisaaki Munakata
- Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
| | - Yoshimasa Sakai
- Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
| |
Collapse
|
2
|
Abstract
Myocardial protection aims to prevent reversible post-ischemic cardiac dysfunction (myocardial stunning) and irreversible myocardial cell death (myocardial infarction) that occur as a consequence of myocardial ischemia and/or ischemic-reperfusion injury. Although the mortality rate for isolated coronary artery bypass grafting has been markedly reduced during the past decade, myocardial death, as evidenced by elevation in creatine kinase-myocardial band and/or cardiac troponin, is common. This is ascribed to suboptimal myocardial protection during cardiopulmonary bypass or with off-pump technique, early graft failure, distal embolization, and regional or global myocardial ischemia during surgery. An unmet need in contemporary coronary bypass surgery is to find more effective cardioprotective strategies that have the potential for decreasing the morbidity and mortality associated with suboptimal cardioprotection. In the present review article on myocardial protection in contemporary coronary artery bypass surgery, we attempt to elucidate the clinical problems, summarize the outcomes of selected phase III trials, and introduce new perspectives.
Collapse
Affiliation(s)
- Takeshi Kinoshita
- Division of Cardiovascular Surgery, Shiga University of Medical Science, Setatsukinowa, Otsu, Japan.
| | | |
Collapse
|
3
|
Sorm Z, Vojacek J, Cermakova E, Pudil R, Stock UA, Harrer J. Elective minimally invasive coronary artery bypass: shunt or tournique occlusion? Assessment of a protective role of perioperative left anterior descending shunting on myocardial damage. A prospective randomized study. J Cardiothorac Surg 2012; 7:69. [PMID: 22809563 PMCID: PMC3487851 DOI: 10.1186/1749-8090-7-69] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2012] [Accepted: 06/16/2012] [Indexed: 11/16/2022] Open
Abstract
Background To determine impact of intraluminal-left anterior descending shunt to prevent myocardial damage in minimally invasive coronary artery bypass. Methods 38 patients were randomly assigned to external tournique occlusion (n = 19) or intraluminal-left anterior descending shunt group (n = 19). Blood samples for cardiac troponin T were collected at 30 minutes prior to, 6 and 24 hours after surgery. Results One patient in external tournique occlusion and two patients in intraluminal-left anterior descending shunt group were excluded from futher analysis due to preoperative cardiac troponin T level above the 99th-percentile. Postoperatively, each six patients in external tournique occlusion (33.3%) and intraluminal-left anterior descending shunt (35.3%) group were above the 99th-percentile. Two patients from each group (external tournique occlusion group 11.1% vs. intraluminal-left anterior descending shunt group 11.8%) had peak values above 10-% coeficient of variation cutoff (p = 1). There were no significant differences in between both groups at all studied timepoints. Conclusion There was no protective effect of intraluminal shunting on myocardial damage compared to short-term tournique occlusion. It is upon the surgeon's discretion which method may preferrably be used to achieve a bloodless field in grafting of the non-occluded left anterior descending in minimally invasive coronary artery bypass.
Collapse
Affiliation(s)
- Zdenek Sorm
- Department of Cardiac Surgery, Charles University in Prague, Faculty of Medicine in Hradec Kralove, University Hospital Hradec Kralove, Sokolska 581, 50005, Hradec Kralove, Czech Republic
| | | | | | | | | | | |
Collapse
|
4
|
Bergsland J. Safe introduction and quality control of new methods in coronary surgery. Acta Inform Med 2011; 19:203-15. [PMID: 23408734 PMCID: PMC3564183 DOI: 10.5455/aim.2011.19.203-215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2011] [Accepted: 12/25/2011] [Indexed: 11/04/2022] Open
Abstract
Introduction: The first part of the paper analyses off pump coronary bypass surgery (OPCAB), which is compared with traditional on-pump procedures (ONCAB). Furthermore ,the paper evaluates the use of a new automatic device for performance of the proximal anastomosis and finally the effect of intracoronary shunt on myocardial ischemia during OPCAB. The main goal of the paper is to demonstrate the importance of careful clinical studies during introduction of the new techniques in cardiac surgery. Methods: Statistical analysis was performed on a large clinical database from Buffalo, NY, USA comparing OPCAB and ONCAB. Subsequently, a sequential controlled clinical study compared patients operated with a new automatic connector device to patients operated with classic suture technique. Finally a randomized study was performed to evaluate the effect of the use of an intracoronary shunt during construction of distal anastomosis. Results: The studies from Buffalo demonstrated reduced complications rates in high risk patients when OPCAB techniques were used. The use of connector devices in saphenous venous anastomosis was clearly inferior to standard technique. Intracoronary shunt was found to be beneficial by preventing ischemia. Discussion: Numerous studies have studied the results of OPCAB vs ONCAB and although results are variable it seems that OPCAB is advantageous in high risk patients, while in low risk patients there are much less if any benefit. The results of the studies of connector devices caused the product to be taken off the market. The value of shunt in OPCAB was clearly demonstrated by the randomized studies. Conclusion: The investigations presented in this paper clearly demonstrates the importance of well-designed studies when new surgical methods are introduced. In the present period of rapid technological development, carefully controlled, un-biased clinical trials are crucial to preserve patient safety and avoid unjustified societal cost.
Collapse
Affiliation(s)
- Jacob Bergsland
- The Interventional Centre, Oslo University Hospital, Oslo, Norway ; BH Heart Centre, Tuzla, Bosnia and Herzegovina
| |
Collapse
|
5
|
Mukherjee D, Ahmed K, Baig K, Patel VM, Darzi A, Athanasiou T. Conversion and Safety in Off-Pump Coronary Artery Bypass: A System Failure That Needs Re-Emphasis. Ann Thorac Surg 2011; 91:630-9. [PMID: 21256340 DOI: 10.1016/j.athoracsur.2010.10.031] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2010] [Revised: 10/12/2010] [Accepted: 11/02/2010] [Indexed: 10/18/2022]
|
6
|
Abstract
Ultrasound applications in perioperative medicine have expanded enormously over the past decade. Transoesophageal echocardiography has been performed by anaesthetists during cardiac surgery for over 20 years. With the increasing availability of portable ultrasound systems, the use of ultrasound to assist in vascular cannulation and regional anaesthesia has been well described. Portable ultrasound systems come with a range of probes for different applications, including transthoracic echocardiography. While transthoracic echocardiography has traditionally been the domain of cardiologists, its use has been increasing in critical care, the emergency room and, recently, by anaesthetists in the perioperative period. Unlike formal cardiology-based transthoracic echocardiography, focused, goal-directed transthoracic echocardiography is often more appropriate in the perioperative period to address a particular question and can be performed in just a few minutes. Transthoracic echocardiography allows rapid, noninvasive, point-of-care assessment of ventricular function, valvular integrity, volume status and fluid responsiveness. It can help distinguish undifferentiated systolic murmurs preoperatively, give valuable information on the aetiology of unexplained hypotension and cardiovascular collapse and assess response to therapeutic interventions such as vasoactive drugs and volume resuscitation. Focused transthoracic echocardiography should include qualitative assessment of left and right ventricular function, an estimate of aortic valve gradient, right ventricular systolic pressure and intravascular volume status as minimum requirements. Transthoracic echocardiography is a valuable tool in the perioperative period and ideally the equipment and expertise should be available in all operating rooms.
Collapse
Affiliation(s)
- B. S. Cowie
- Department of Anaesthesia, St. Vincent's Hospital, Melbourne, Victoria, Australia
| |
Collapse
|
7
|
Letsou GV, Grunkemeier GL, Salaskar AL, Bavare C, Wu Y, Rampurwala MM. Selective Left Anterior Descending Shunting Provides Effective Off-pump Myocardial Protection. Ann Thorac Surg 2010; 89:24-9. [DOI: 10.1016/j.athoracsur.2009.09.031] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2009] [Revised: 09/14/2009] [Accepted: 09/15/2009] [Indexed: 10/20/2022]
|
8
|
Sasaki H. Coronary artery bypass grafting without full sternotomy. Surg Today 2009; 39:929-37. [PMID: 19882313 DOI: 10.1007/s00595-009-3976-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2008] [Accepted: 04/05/2009] [Indexed: 10/20/2022]
Abstract
Coronary artery bypass grafting is performed without full sternotomy in selected patients because it is less invasive. Left internal thoracic artery-left anterior descending artery bypass (LITA-LAD bypass) via a small left anterior thoracotomy is a well established procedure, which achieves good graft patency with low mortality and morbidity rates. Multiple revascularization is possible with a limited lateral thoracotomy or L-figure approach. Axillary-coronary bypass and right gastroepiploic artery-right coronary artery bypass (RGEA-RCA bypass) are alternative methods, especially for redo surgery, in selected patients.
Collapse
Affiliation(s)
- Hideki Sasaki
- Department of Cardiothoracic Surgery, The University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390, USA
| |
Collapse
|
9
|
Bergsland J, Lingaas PS, Skulstad H, Hol PK, Halvorsen PS, Andersen R, Småstuen M, Lundblad R, Svennevig J, Andersen K, Fosse E. Intracoronary Shunt Prevents Ischemia in Off-Pump Coronary Artery Bypass Surgery. Ann Thorac Surg 2009; 87:54-60. [PMID: 19101268 DOI: 10.1016/j.athoracsur.2008.08.032] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2008] [Revised: 08/12/2008] [Accepted: 08/13/2008] [Indexed: 10/21/2022]
|
10
|
Hangler H, Mueller L, Ruttmann E, Antretter H, Pfaller K. Shunt or Snare: Coronary Endothelial Damage due to Hemostatic Devices for Beating Heart Coronary Surgery. Ann Thorac Surg 2008; 86:1873-7. [PMID: 19022000 DOI: 10.1016/j.athoracsur.2008.06.047] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2008] [Revised: 06/04/2008] [Accepted: 06/09/2008] [Indexed: 11/27/2022]
|
11
|
Vural AH, Yalcinkaya S, Türk T, Yümün G, Gül N, Yalcinkaya U, Kaya M, Ozyazicioğlu A. Intracoronary shunt versus bulldog clamp in off-pump bypass surgery. Endothelial trauma: shunt versus clamp. J Surg Res 2008; 150:261-5. [PMID: 18262555 DOI: 10.1016/j.jss.2007.12.774] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2007] [Revised: 10/25/2007] [Accepted: 12/06/2007] [Indexed: 11/24/2022]
Abstract
BACKGROUND During off-pump coronary bypass grafting, local vascular control of the target vessel and a bloodless field are crucial. The aim of this study is to asses the histopathological outcomes of intracoronary shunts and bulldog clamping on the beating heart in a canine model. METHODS Twelve healthy adult mongrel dogs weighing between 15 to 25 kg were included in the study. Following left thoracotomy, proximal left anterior descending artery segment 1 cm to distal of diagonal branch was marked. Arteriotomy at this site was performed and a shunt was inserted for 10 min in the shunt group. The bulldog clamp was applied 3 cm distal to the mark for 10 min after heparinization in the bulldog group. Thirty days after the procedure, the specimens of left anterior descending artery from both regions were collected and were examined. Vascular damage, presence of intimal hyperplasia, and denudation were noted. RESULTS Only intimal denudation was found significantly higher in the shunt group (P < 0.05). In this group, only one case had grade 0 endothelial damage. In the bulldog group, all cases had endothelial damage of various grades. CONCLUSION The proven advantages of temporary intracoronary shunts are well-known, e.g., preserving the ventricular functions. Despite these advantages, our study revealed an ultimate bad result for an off-pump coronary by pass patient: intimal denudation. We conclude that further studies with a larger number of subjects are needed to decide whether routine shunt insertion into coronary arteries during off-pump coronary bypass surgery is appropriate or not.
Collapse
Affiliation(s)
- A Hakan Vural
- Department of Cardiovascular Surgery, Bursa Yüksek Ihtisas Education and Research Hospital, Bursa, Turkey.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Kim HK, Kim HJ, Kim JW, Sohn YS, Choi YH. Changes in N-terminal pro B-type natriuretic peptide concentration: comparative study of percutaneous transluminal coronary angioplasty and off-pump coronary artery bypass graft. J Korean Med Sci 2007; 22:16-9. [PMID: 17297245 PMCID: PMC2693558 DOI: 10.3346/jkms.2007.22.1.16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
The goal of this study was to compare the effects of different reperfusion methods on N-terminal B-type natriuretic peptide (NT-proBNP) in percutaneous transluminal coronary angioplasty (PTCA) or off-pump coronary artery bypass (OPCAB) patients. Fifty subjects were enrolled in the study, 32 patients received PTCA and 18 OPCAB. An NT-proBNP measurement was performed before intervention and at 1, 3, and 7 days after the procedures. NT-proBNP levels were not significantly different before intervention (PTCA group 297+/-147.3 vs. OPCAB group 235+/-167.8 pg/mL, p>0.05). However, 1 day after the procedures, NT-proBNP levels were higher in the OPCAB group (PTCA 375+/-256.4 vs. OPCAB 1,415+/-737.6 pg/mL, p<0.05), after 3 days NT-proBNP reached peak levels (PTCA 480+/-363.0 vs. OPCAB 2,119+/-818.4 pg/mL, p<0.05), and levels were reduced after 7 days (PTCA 292+/-243.7 vs. OPCAB 522+/-334.0 pg/mL, p>0.05). PTCA induced a mild and transient increase in NT-proBNP concentration, but OPCAB caused sustained high NT-proBNP levels during the 7 day postoperatively. However, differences between NT-proBNP levels associated with these two modalities showed a tendency to decrease rapidly postoperatively.
Collapse
Affiliation(s)
- Hyun Koo Kim
- Department of Thoracic and Cardiovascular Surgery, Korea University Medical Center, Seoul, Korea
| | - Hark Jei Kim
- Department of Thoracic and Cardiovascular Surgery, Korea University Medical Center, Seoul, Korea
| | - Jin Won Kim
- Department of Cardiology, Korea University Medical Center, Seoul, Korea
| | - Young-sang Sohn
- Department of Thoracic and Cardiovascular Surgery, Korea University Medical Center, Seoul, Korea
| | - Young Ho Choi
- Department of Thoracic and Cardiovascular Surgery, Korea University Medical Center, Seoul, Korea
| |
Collapse
|
13
|
Collison SP, Agarwal A, Trehan N. Controversies in the Use of Intraluminal Shunts During Off-Pump Coronary Artery Bypass Grafting Surgery. Ann Thorac Surg 2006; 82:1559-66. [PMID: 16996987 DOI: 10.1016/j.athoracsur.2006.05.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2006] [Revised: 05/03/2006] [Accepted: 05/04/2006] [Indexed: 10/24/2022]
Abstract
Technical advances have made the performance of multivessel off-pump coronary artery bypass feasible. Snaring and intraluminal shunts are the techniques used for vascular control. Snaring provides a bloodless surgical field, is usually well tolerated by the patient, and is supported by years of clinical experience. Intraluminal shunts aim to achieve hemostasis at the arteriotomy site and to allow antegrade flow to provide myocardial protection. There are unresolved issues regarding whether shunts have a clinical benefit, do provide adequate flow to provide myocardial protection, and whether they cause significant endothelial damage. In this article, we have reviewed the literature to lend perspective to these issues.
Collapse
|
14
|
Achurin R, Lepilin M, Bajalieva A, Torshin S, Lepilin P. Peculiarities of Hemodynamic Changes During High Thoracic Epidural Anesthesia in Beating Heart Surgery. ELECTRONIC JOURNAL OF GENERAL MEDICINE 2005. [DOI: 10.29333/ejgm/82330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
15
|
Arai H, Kozakai A, Manabe S, Kawaguchi S, Shimizu M, Egi K, Tabuchi N, Tanaka H, Sunamori M. Perfusion Flow Assessment of Coronary Shunt during Off-Pump Coronary Artery Bypass Grafting. Heart Surg Forum 2005; 7:E136-40. [PMID: 15138091 DOI: 10.1532/hsf98.200371320] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Coronary shunts are widely used to prevent myocardial ischemia during off-pump coronary artery bypass graft (OPCAB) procedures. Although clinical effectiveness has been reported, actual perfusion flow has not been well assessed. The purpose of this study was to evaluate actual shunt flow and its pattern during passive coronary perfusion in clinical OPCAB. METHODS In 15 OPCAB cases, the coronary perfusion flow of the external shunt (1.7 or 2.0 mm) during anastomosis and the free flow of the shunt were measured with an in-line electromagnetic or ultrasonic flow probe. The perfused coronary blood vessel was either the left anterior descending coronary artery or the right coronary artery. The inflow vessel of the external shunt was either the femoral artery (FA) or the ascending aorta (AA). RESULTS Free flow values of a 1.7-mm FA shunt, 1.7-mm AA shunt, and 2.0-mm FA shunt were 34+/- 7, 39 +/- 3, and 44 +/- 7 mL/min. Perfusion flows were 13 +/- 4, 14 +/- 3, and 22 +/- 4 mL/min, respectively. Perfusion flow was significantly lower than free flow and correlated well with coronary resistance. Although inflow site did not influence net perfusion flow, diastolic/systolic flow fraction ratio was significantly greater when the shunt was perfused from the FA. CONCLUSIONS External shunt from FA would provide limited but effective perfusion flow with a physiological pattern, which is passively regulated by coronary resistance.
Collapse
Affiliation(s)
- Hirokuni Arai
- Department of Cardiothoracic Surgery, Tokyo Medical and Dental University Graduate School of Medicine, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Wippermann J, Albes JM, Bruhin R, Hartrumpf M, Vollandt R, Kosmehl H, Wahlers T. Chronic ultrastructural effects of temporary intraluminal shunts in a porcine off-pump model. Ann Thorac Surg 2004; 78:543-8. [PMID: 15276516 DOI: 10.1016/j.athoracsur.2004.02.099] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/18/2004] [Indexed: 10/26/2022]
Abstract
BACKGROUND Temporary intraluminal shunts (TILS) are routinely used in off-pump revascularization to facilitate the anastomosis while maintaining myocardial blood supply. Whereas tourniquet-occlusion can cause vessel wall trauma, potentially adverse chronic effects of TILS on the coronary intima have not been evaluated yet. This chronic large animal study investigated ultrastructural effects of TILS on the vessel wall. METHODS Four groups of acute and chronic pigs with either tourniquet-occlusion (TOUR) or TILS (40 kg; acute, n = 12; chronic, n = 20) were analyzed. Animals underwent median sternotomy, heparin (150 U/kg) administration, and left anterior descending coronary artery exposure. In groups with TOUR the left anterior descending coronary artery was temporarily occluded (10 minutes) with a tourniquet. In groups with TILS a silicone shunt (1.5 mm diameter, 12 mm length) was placed in the left anterior descending coronary artery more than 10 minutes and then removed, and the insertion was repaired. Thirty minutes after reperfusion all acute animals were sacrificed whereas chronic animals were extubated, maintained for 3 months, and then sacrificed. The left anterior descending coronary artery regions of occlusion or placement of the TILS silicone bulbs were examined histopathologically by scanning and transmission electron microscopy by a blinded pathologist. RESULTS In both acute and chronic investigations animals in the TILS group exhibited significantly less morphologic damage than animals in the TOUR group. In the acute phase significantly more loss of cell junction (p = 0.037), loss of endothelium (p = 0.032), and intimal edema (p = 0.037) in the TOUR group than in the TILS group was observed. Three months later, characteristic features with a changed pattern were detected: vacuolization of the cell (p = 0.03), loss of cell junction (p = 0.042), and removal of basal membrane (p = 0.046) as well as extensive loss of endothelium (p = 0.003) in the TOUR group compared with the TILS group. CONCLUSIONS Intimal lesions occur with both maneuvers early and late. However, animals in the TOUR group exhibited injuries significantly more often and more severely. Therefore, acute and chronic intimal integrity of the coronary vessel may be better preserved using TILS and may thus have a positive impact on the extent of de novo stenosis and long-term prognosis of the revascularized region.
Collapse
Affiliation(s)
- Jens Wippermann
- Department of Cardiothoracic and Vascular Surgery, University Hospital Jena, Erlanger Allee 101, 07747 Jena-Lobeda, Germany.
| | | | | | | | | | | | | |
Collapse
|
17
|
Zimarino M, Gallina S, Di Fulvio M, Di Mauro M, Di Giammarco G, De Caterina R, Calafiore AM. Intraoperative ischemia and long-term events after minimally invasive coronary surgery. Ann Thorac Surg 2004; 78:135-41. [PMID: 15223418 DOI: 10.1016/j.athoracsur.2003.12.030] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/02/2003] [Indexed: 10/26/2022]
Abstract
BACKGROUND Concern has been raised about the effects of prolonged left anterior descending (LAD) artery occlusion during minimally invasive direct coronary artery bypass graft surgery (MIDCABG). We sought to assess the impact of myocardial dysfunction during MIDCABG on long-term outcome and the protective role of collateral circulation on myocardial ischemia. METHODS Myocardial function was evaluated in 92 patients by intraoperative transesophageal echocardiography during MIDCABG. RESULTS Wall motion score index increased during LAD occlusion (p < 0.00l) and reverted after LAD reopening (p < 0.001 versus occlusion and p = not significant versus baseline). The change in wall motion score index (occlusion versus baseline) was higher in patients with multivessel disease (p < 0.05) and in patients with LAD Thrombolysis in Myocardial Infarction study classification flow grade 2 or less without collateral circulation (p < 0.05). Myocardial stunning was documented in 12 patients (13%). The 5-year adverse event rate (including death, myocardial infarction, and revascularization) was 12%. By multivariate Cox regression analysis, multivessel disease, but not perioperative ischemia or stunning, was the only predictor of event-free survival. CONCLUSIONS During MIDCABG anterior wall dysfunction is transient, with prompt recovery after completion of the anastamosis in most cases; myocardial stunning can be documented in a minority of patients. Flow either antegrade or retrograde in the LAD territory plays a protective role against the development of ischemia. Multivessel disease, but not perioperative ischemia or stunning, predicts long-term event-free survival.
Collapse
Affiliation(s)
- Marco Zimarino
- Department of Cardiology and Cardiac Surgery, G. D'Annunzio University of Chieti, Italy.
| | | | | | | | | | | | | |
Collapse
|
18
|
Hangler HB, Pfaller K, Ruttmann E, Hoefer D, Schachner T, Laufer G, Antretter H. Effects of intracoronary shunts on coronary endothelial coating in the human beating heart. Ann Thorac Surg 2004; 77:776-80. [PMID: 14992870 DOI: 10.1016/j.athoracsur.2003.08.052] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/19/2003] [Indexed: 10/26/2022]
Abstract
BACKGROUND Local occlusion of coronary arteries during beating heart revascularization leads to injury of the arterial wall especially disturbing the integrity of the endothelium. The aim of this study was to elucidate the effects of intracoronary shunts versus local occlusion with elastic silicone loops on the beating heart in human coronary arteries by scanning electron microscopy. METHODS Coronary arteries of patients with dilated cardiomyopathy (n = 4) or ischemic heart disease (n = 8) undergoing heart transplantation were locally occluded either with a silicone loop or with a shunt inserted after arteriotomy. Unmanipulated segments of the coronary arteries served as controls. Integrity of the endothelial lining was observed with scanning electron microscopy. RESULTS Scanning electron microscopy revealed a statistically significant higher injury after shunting compared with controls (p < 0.001) and vessel loop occlusion (p < 0.001). There was no difference between both patient groups according to control specimens or after manipulation. CONCLUSIONS From this investigation we conclude that insertion of intracoronary shunts during beating heart surgery leads to severe endothelial denudation in human coronary arteries. Therefore, at present we recommend using intracoronary shunts selectively in cases in which critical ischemia or technical difficulties as a result of anatomic conditions are expected during anastomosis and avoiding routine shunt insertion into coronary arteries during beating heart revascularization.
Collapse
Affiliation(s)
- Herbert B Hangler
- Department of Cardiac Surgery, Institute of Anatomy Histology and Embryology, Leopold-Franzens-University, Innsbruck, Austria.
| | | | | | | | | | | | | |
Collapse
|
19
|
Abstract
Over the past 5 years, many coronary artery surgeons have embraced technology and advanced the field of beating heart surgery to the point where off-pump coronary artery bypass (OPCAB) is becoming a mature procedure. Enabling technologies are now available for all stages of the procedure, including cardiac positioning, coronary artery stabilization, coronary artery visualization, and performance of the proximal and distal anastomoses. Despite these successes, only a minority of cardiac surgeons performs this procedure routinely. Proponents of OPCAB and the medical device industry will need to continue to develop new technologies to make OPCAB less technically challenging and more widely accepted. Progress towards routine single-vessel off-pump totally endoscopic coronary artery bypass has been slow. Translating the benefits of multivessel OPCAB to an endoscopic setting remains a formidable challenge that will require further technologic breakthroughs.
Collapse
Affiliation(s)
- Lishan Aklog
- Department of Cardiothoracic Surgery Mount Sinai Medical Center New York, NY 10029, USA
| |
Collapse
|