1
|
Khan AM, Ullah Z, Ilyas S, Wazir HD, Rehman Y, Hussain I, Sadia H. The Outcome of Trans-catheter Closure of Patent Ductus Arteriosus: A Single-Center Experience. Cureus 2022; 14:e21577. [PMID: 35228936 PMCID: PMC8867018 DOI: 10.7759/cureus.21577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/24/2022] [Indexed: 11/05/2022] Open
Abstract
Objective The objective is to share our experience of trans-catheter device closure of patent ductus arteriosus (PDA) and review its efficacy and immediate complications. Methodology This cross-sectional observational study was done in the Department of Pediatric cardiology, Lady Reading Hospital, Peshawar from January 2020 to December 2020. A total of 51 patients with isolated PDA, who underwent PDA device closure, were enlisted in this study through consecutive sampling methods, irrespective of their age and gender. Data of the patients were collected on preformed pro forma. Data was entered in SPSS 20 (SPSS Inc., Chicago, IL, USA). Descriptive statistics like mean ± SD for numerical data (age, weight, and hospital stay), while frequency and percentage for categorical variables (Device type, complication, hospital stay, and type of anesthesia given) were calculated. Results Among total 51 patients (33 [64.7%] females and 18 [35.3%] males) with mean age 8.19 ± 6.96 years underwent attempted trans-catheter PDA device closure. In all cases PDA was successfully occluded with appropriate size devices. General anesthesia was given in 38 (74.5%) patients. Complications occurred in only four (7.8%) patients in the form of hemolysis followed by acute kidney injury in one patient, another had device embolization to descending aorta, which was retrieved in cath lab, one had device embolization to the right pulmonary artery, which was retrieved in cath lab and one had mild left ventricular systolic dysfunction. The mean duration of hospital stay was 22.0 ± 10.2 h. Conclusion Trans-catheter PDA device closure is a safe procedure with a high success rate and little morbidity.
Collapse
|
2
|
Lee SJ, Yoo SM, Son MJ, White CS. The Patent Ductus Arteriosus in Adults with Special Focus on Role of CT. Diagnostics (Basel) 2021; 11:diagnostics11122394. [PMID: 34943630 PMCID: PMC8699958 DOI: 10.3390/diagnostics11122394] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 12/17/2021] [Accepted: 12/17/2021] [Indexed: 11/16/2022] Open
Abstract
The primary imaging modality for the diagnosis of patent ductus arteriosus (PDA) is echocardiography. However, CT may be the technique on which an incidental PDA is first recognized because of the increasing number of chest CT scans performed for a variety of causes. Identification of PDA on CT may lead to earlier closure using a PDA occluder device. Immediate identification of incidental PDA is important, but a high rate of missed diagnosis of PDA has been reported due to its small size and anatomic location. In addition, echocardiography may overlook the presence of even a large PDA due to decrease in the amount of shunting through the PDA caused by high pulmonary artery pressures. This review provides the basic CT anatomy and clinical perspective of PDA, and discusses the role of CT in the evaluation of PDA as well as methods to avoid overlooking a small PDA on CT.
Collapse
Affiliation(s)
- Soo Jeong Lee
- Department of Radiology, CHA University Kangnam Medical Ceneter, Seoul 06135, Korea;
| | - Seung Min Yoo
- Department of Radiology, CHA University Bundang Medical Ceneter, Seongnam 13497, Korea;
- Correspondence: (S.M.Y.); (C.S.W.); Tel.: +82-3-780-5423 (S.M.Y.); 410-328-0641 (C.S.W.)
| | - Min Ji Son
- Department of Radiology, CHA University Bundang Medical Ceneter, Seongnam 13497, Korea;
| | - Charles S. White
- Department of Radiology, University of Maryland, Baltimore, MD 21201, USA
- Correspondence: (S.M.Y.); (C.S.W.); Tel.: +82-3-780-5423 (S.M.Y.); 410-328-0641 (C.S.W.)
| |
Collapse
|
3
|
Arévalo Salas LA, Solano Fiesco L, Villatoro Fernández JL. [Percutaneous closure of ductus arteriosus through an arteriovenous loop in a patient with scimitar syndrome]. BOLETIN MEDICO DEL HOSPITAL INFANTIL DE MEXICO 2018; 74:55-59. [PMID: 29364815 DOI: 10.1016/j.bmhimx.2016.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2014] [Accepted: 07/25/2016] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND Scimitar syndrome consists in a rare malformation characterized by a partial abnormal connection in one or both right pulmonary veins to the inferior vena cava, right lung hypoplasia and systemic circulation from the descending aorta. Scimitar syndrome is occasionally associated to other congenital malformations, such as patent ductus arteriosus (PDA). CASE REPORT We report a 4-year-old patient with "adult" variety of scimitar syndrome associated to symptomatic PDA, which was successfully occluded using retrograde guidewire-established femoral arteriovenous loop with an Amplatzer® PDA occluder, without complications. CONCLUSIONS Scimitar syndrome is complex and requires a complete hemodynamic study for the determination of the appropriate treatment. Pulmonary arterial hypertension is a factor associated with poor prognosis.
Collapse
Affiliation(s)
| | - Liborio Solano Fiesco
- Departamento de Cardiología, Hospital Infantil de México Federico Gómez, Ciudad de México, México
| | | |
Collapse
|
4
|
Wen B, Yang J, Liu H, Jiao Z, Zhao W. Pulmonary artery closure in combination with patch technique for treating congenital heart disease combined with large patent ductus arteriosus: A clinical study of 9 cases. Pak J Med Sci 2016; 32:539-44. [PMID: 27375685 PMCID: PMC4928394 DOI: 10.12669/pjms.323.9872] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Objective: To document clinical experience of treating congenital heart disease combined with large patent ductus arteriosus with pulmonary artery closure in combination with patch technique. Methods: Thirty-six patients (8 males and 28 females) who suffered from congenital heart disease and underwent hybrid surgery in the First Affiliated Hospital of Zhengzhou University from October 2010 to February 2014 were selected for this study. They aged 14 to 39 years and weighed 32.20 to 61.50 kg. Diameter of arterial duct was between 10 mm and 13 mm; 28 cases were tube type, 4 cases were funnel type and four cases were window type. All patients had moderate or severe pulmonary arterial hypertension; besides, there were 28 cases of ventricular septal defect, 16 cases of atrial septal defect, eight cases of aortic insufficiency, four cases of mitral stenosis and insufficiency and four cases of infectious endocarditis. Cardz Pulmonary Bypass (CPB) was established after chest was opened along the middle line. With the help of Transesophageal echocardiography, large patent ductus arteriosus was blocked off through pulmonary artery. Pulmonary artery was cut apart after blocking of heart. Large patent ductus arteriosus on the side of pulmonary artery was strengthened with autologous pericardial patch. Results: Of 36 patients, 32 patients had patent ductus arteriosus closure device and four patients had atrial septal defect closure device. Pulmonary arteries of 36 cases were all successfully closed. Systolic pressure declined after closure ((54.86±19.23) mmHg vs (96.05±23.07) mmHg, p<0.05); average pulmonary arterial pressure also declined after closure ((39.15±14.83) mmHg vs (72.88±15.76) mmHg, p<0.05). The patients were followed up for one to fifty one months (average 11.5 months). Compared to before surgery, left atrial diameter, left ventricular diameter and pulmonary artery diameter all narrowed after surgery. Besides, clinical symptoms were relieved and cardiac function of the patients also improved. Conclusion: Hybrid surgery is feasible and safe in treating patients with large patent ductus arteriosus and congenital heart disease, which decreases surgical problems, shortens surgical time and lowers the incidence of complications.
Collapse
Affiliation(s)
- Bing Wen
- Bing Wen, Department of Cardiovascular Surgery, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Junya Yang
- Junya Yang, Department of Dermatological, the Fifth Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Huiruo Liu
- Huiruo Liu, Department of Cardiovascular Surgery, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Zhouyang Jiao
- Zhouyang Jiao, Department of Cardiovascular Surgery, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Wenzeng Zhao
- Wenzeng Zhao, Department of Cardiovascular Surgery, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| |
Collapse
|
5
|
Rangel A, Pérez-Redondo H, Farell J, Basave MN, Zamora C. Division or Occlusion of Patent Ductus Arteriosus? Angiology 2016; 54:695-700. [PMID: 14666958 DOI: 10.1177/000331970305400609] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The traditional and most effective form of treatment of persistent ductus arteriosus is surgical ductal division. New therapeutic techniques such as intraluminal ductal occlusion are currently recommended to replace the traditional treatment procedure. The purpose of this paper is to analyze the state of the art of these new therapeutic modalities. From reports in the medical literature, the authors analyzed the indications, results, and complications of the intraluminal ductal occlusion procedures. They applied the Student's t test for independent samples to evaluate the results of intraluminal patent ductus arteriosus occlusion by means of umbrellas, buttons, coils, and Gianturco-Grifka and Amplatzer occluders, respectively, in 2,691 patients collected from the medical literature. According to their analysis the results of intraluminal ductal occlusion with coils were as follows: success 83.7 ±12.2%, failure 3.9 ±2.8%, incom plete ductal occlusion 17.5 ±15.3%, need for surgery 2.8 ±3.8%, need for a second intraluminal procedure 5.8 ±9.9%, and device embolization 6.2 ±7.2%. The use of the Gianturco-Grifka device showed the following results: success 96.0 ±5.6%, failure 4.0 ±5.6%, incomplete ductal occlusion 4.0 ±5.6%, need for surgery 0%, need for a second intraluminal procedure 4.0 ±5.6%, and device embolization 4.0 ±5.6%. The Amplatzer occluder showed the following results: success 92.8 ±6.1%, failure 7.2 ±6.1%, incomplete ductal occlusion 2.0 ±4.3%, need for surgery 0%, need for a second intraluminal procedure 0.8 ±1.7%, and device embolization 0.5 ±1.3%. According to the state of the art, intraluminal ductal occlusion with Gianturco-Grifka device and Amplatzer occluder reduces the proportion of incomplete obstructions and need for surgery. Additionally, the use of the Amplatzer occluder reduces need for a second procedure and the embolization rate. Although the results obtained with the new procedures are better than those obtained previously, they are still not totally satisfactory.
Collapse
Affiliation(s)
- Alberto Rangel
- Departamento de Hemodinamia, Hospital de Especialidades, Centro Médico Nacional La Raza, IMSS, México, DF, México.
| | | | | | | | | |
Collapse
|
6
|
Baruteau AE, Hascoët S, Baruteau J, Boudjemline Y, Lambert V, Angel CY, Belli E, Petit J, Pass R. Transcatheter closure of patent ductus arteriosus: past, present and future. Arch Cardiovasc Dis 2014; 107:122-32. [PMID: 24560920 DOI: 10.1016/j.acvd.2014.01.008] [Citation(s) in RCA: 88] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2013] [Revised: 01/15/2014] [Accepted: 01/20/2014] [Indexed: 11/29/2022]
Abstract
This review aims to describe the past history, present techniques and future directions in transcatheter treatment of patent ductus arteriosus (PDA). Transcatheter PDA closure is the standard of care in most cases and PDA closure is indicated in any patient with signs of left ventricular volume overload due to a ductus. In cases of left-to-right PDA with severe pulmonary arterial hypertension, closure may be performed under specific conditions. The management of clinically silent or very tiny PDAs remains highly controversial. Techniques have evolved and the transcatheter approach to PDA closure is now feasible and safe with current devices. Coils and the Amplatzer Duct Occluder are used most frequently for PDA closure worldwide, with a high occlusion rate and few complications. Transcatheter PDA closure in preterm or low-bodyweight infants remains a highly challenging procedure and further device and catheter design development is indicated before transcatheter closure is the treatment of choice in this delicate patient population. The evolution of transcatheter PDA closure from just 40 years ago with 18F sheaths to device delivery via a 3F sheath is remarkable and it is anticipated that further improvements will result in better safety and efficacy of transcatheter PDA closure techniques.
Collapse
Affiliation(s)
- Alban-Elouen Baruteau
- M3C Marie-Lannelongue Hospital, Paediatric and Congenital Cardiac Surgery, Paris Sud University, Paris, France; Inserm UMR 1087, CNRS UMR 6291, l'Institut du Thorax, Nantes University, Nantes, France.
| | - Sébastien Hascoët
- M3C CHU Toulouse, Children's Hospital, Paediatric Cardiology, Paul-Sabatier University, Toulouse, France
| | - Julien Baruteau
- Great Ormond Street Hospital for Children, Metabolic Medicine Department, University College London, Institute for Women's Health, Gene Therapy Transfer Group, London, UK
| | - Younes Boudjemline
- M3C Necker Hospital for Sick Children, Paediatric Cardiology, Paris Descartes University, Paris, France; M3C Georges-Pompidou European Hospital, Adult Congenital Cardiology, Paris, France
| | - Virginie Lambert
- M3C Marie-Lannelongue Hospital, Paediatric and Congenital Cardiac Surgery, Paris Sud University, Paris, France; Inserm UMR 999, Marie-Lannelongue Hospital, Paris, France
| | - Claude-Yves Angel
- M3C Marie-Lannelongue Hospital, Paediatric and Congenital Cardiac Surgery, Paris Sud University, Paris, France
| | - Emre Belli
- M3C Marie-Lannelongue Hospital, Paediatric and Congenital Cardiac Surgery, Paris Sud University, Paris, France
| | - Jérôme Petit
- M3C Marie-Lannelongue Hospital, Paediatric and Congenital Cardiac Surgery, Paris Sud University, Paris, France
| | - Robert Pass
- Children's Hospital at Montefiore, Pediatric Cardiology, Albert Einstein College of Medicine, Yeshiva University, Bronx, NY, USA
| |
Collapse
|
7
|
Abstract
Patent ductus arteriosus (PDA) is one of the most common congenital heart defects. Although surgery is still required in symptomatic neonates, the majority of older infants and children can undergo safe and effective transcatheter device closure on an out-patient basis. First described in 1967, over the past four decades, numerous devices have been specifically developed for this purpose. This article will review the current status of transcatheter therapy. The experience with each device is detailed and issues and controversies are reviewed.
Collapse
Affiliation(s)
- Jennifer M Rutledge
- Division of Pediatric Cardiology, Stollery Children's Hospital, University of Alberta, Edmonton, Alberta, Canada.
| |
Collapse
|
8
|
El-Said HG, Bratincsak A, Foerster SR, Murphy JJ, Vincent J, Holzer R, Porras D, Moore J, Bergersen L. Safety of percutaneous patent ductus arteriosus closure: an unselected multicenter population experience. J Am Heart Assoc 2013; 2:e000424. [PMID: 24284214 PMCID: PMC3886754 DOI: 10.1161/jaha.113.000424] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background The technique and safety of transcatheter patent ductus arteriosus (PDA) closure have evolved during the past 20 years. We sought to report a multicenter experience of PDA closure with a focus on the rate of adverse events (AE) and a review of institutional practice differences. Methods and Results Outcome data on transcatheter PDA closure were collected at 8 centers prospectively using a multicenter registry (Congenital Cardiac Catheterization Project on Outcome Registry). Between February 2007 and June 2010, 496 PDA closures were recorded using a device in 338 (68%) or coils in 158 (32%). Most patients had an isolated PDA (90%). Fifty percent of patients were between 6 months and 3 years old, with only 40 patients (8%) <6 months old. Median minimum PDA diameter was 2.5 mm (range 1 to 12 mm; IQR 2 to 3 mm) for device closure and 1 mm (range 0.5 to 6 mm; IQR 1 to 2 mm) for coil closure (P<0.001). A device rather than coil was used in patients <3 years, weight <11 kg, and with a PDA minimum diameter >2 mm (all P<0.001). Three of 8 centers exclusively used a device for PDAs with a diameter >1.5 mm. In 9% of cases (n=46), an AE occurred; however, only 11 (2%) were classified as high severity. Younger age was associated with a higher AE rate. Coil‐related AEs were more common than device‐related AEs (10% versus 2%, P<0.001). Conclusions PDA closure in the present era has a very low rate of complications, although these are higher in younger children. Technical intervention‐related events were more common in coil procedures compared with device procedures. For PDAs ≤2.5 mm in diameter, institutional differences in preference for device versus coil exist.
Collapse
|
9
|
Abstract
During fetal life, the ductus arteriosus is a normal and essential structure that connects the pulmonary artery to the distal aortic arch, permitting right ventricular ejection into the aorta. After birth, with commencement of pulmonary blood flow and a 2-ventricle circulation, a variety of physiological and biochemical signals normally result in complete closure of the ductus. Persistent patency of the ductus arteriosus may impair systemic cardiac output and result in deleterious effects on the cardiovascular system and lungs. Although surgery is still the treatment of choice for most premature infants with patent ductus arteriosus (PDA), transcatheter techniques have largely supplanted surgery for closure of PDA in children and adults. This article is a review of the PDA in term infants, children, and adults, with focus on the clinical manifestations and management.
Collapse
Affiliation(s)
- Douglas J Schneider
- Division of Pediatric Cardiology, Department of Pediatrics, University of Kentucky, Lexington, KY 40536, USA.
| |
Collapse
|
10
|
Roushdy A, Fiky AE, Din DEE. Visualization of patent ductus arteriosus using real-time three-dimensional echocardiogram: Comparative study with 2D echocardiogram and angiography. J Saudi Heart Assoc 2012; 24:177-86. [PMID: 23960692 DOI: 10.1016/j.jsha.2012.02.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2011] [Revised: 01/27/2012] [Accepted: 02/04/2012] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To determine the feasibility and accuracy of real time 3D echocardiography (RT3DE) in determining the dimensions and anatomical type of the patent ductus arteriosus (PDA). METHODS The study included 42 pediatric patients with a mean age of 3.6 years (ranging from 2 months to 14 years) who were referred for elective percutaneous PDA closure. All patients underwent full 2D echocardiogram as well as RT3DE with off line analysis using Q lab software within 6 h from their angiograms. The PDA was studied as regard the anatomical type, length of the duct as well as the ampulla and the pulmonary end of the PDA. Data obtained by RT3DE was compared against 2D echocardiogram and the gold standard angiography. RESULTS Offline analysis of the PDA was feasible in 97.6% of the cases while determination of the anatomical type using gated color flow 3D acquisitions was achieved in 78.5% of the cases. The pulmonary end of the duct was rather elliptical using 3D echocardiogram. There was significant difference between the pulmonary end measured by 3D echocardiogram and angiography (P < 0.001). There was no significant difference between either the length or the ampulla of the PDA measured by 3D echocardiogram and that measured by angiography (P value = 0.325 and 0.611, respectively). There was a good agreement between both 2D or 3D echocardiogram and angiography in determining the anatomical type of the PDA (K = 0.744 and 0.773, respectively). However 3D echocardiogram could more accurately determine type A and type E ductus compared to 2D echocardiogram. CONCLUSION 3D echocardiogram was more accurate than 2D echocardiogram in determining the length and the ampulla of the PDA. The morphologic assessment of the PDA using gated 3D color flow was achieved in 78.5% of the patients. Nevertheless the use of 3D echocardiogram in assessment of small vascular structures like PDA in children with rapid heart rates is still of limited clinical value.
Collapse
Affiliation(s)
- Alaa Roushdy
- Cardiology Department, Ain Shams University Hospital, Cairo
| | | | | |
Collapse
|
11
|
Galal MO, Hussain A, Arfi AM. Do we still need the surgeon to close the persistently patent arterial duct? Cardiol Young 2006; 16:522-36. [PMID: 17116265 DOI: 10.1017/s1047951106001314] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/15/2006] [Indexed: 11/06/2022]
Affiliation(s)
- Mohammed O Galal
- King Faisal Specialist Hospital and Research Centre, Jeddah, Saudi Arabia.
| | | | | |
Collapse
|
12
|
MESH Headings
- Abnormalities, Multiple
- Adult
- Aneurysm/etiology
- Child
- Diagnostic Techniques, Cardiovascular
- Dinoprostone/physiology
- Ductus Arteriosus/embryology
- Ductus Arteriosus/physiology
- Ductus Arteriosus, Patent/diagnosis
- Ductus Arteriosus, Patent/embryology
- Ductus Arteriosus, Patent/epidemiology
- Ductus Arteriosus, Patent/physiopathology
- Ductus Arteriosus, Patent/surgery
- Ductus Arteriosus, Patent/therapy
- Eisenmenger Complex/etiology
- Eisenmenger Complex/physiopathology
- Epoprostenol/physiology
- Heart Failure/etiology
- Humans
- Hypertension, Pulmonary/etiology
- Incidence
- Infant
- Infant, Newborn
- Oxygen/blood
Collapse
Affiliation(s)
- Douglas J Schneider
- University of Illinois College of Medicine at Peoria, and Cardiac Catheterization Laboratory, Children's Hospital of Illinois, 420 NE Glen Oak Ave, Suite 304, Peoria, IL 61603, USA.
| | | |
Collapse
|
13
|
Abstract
While describing the circulatory system in De Moto Cordis, in 1628, William Harvey developed precepts for investigation, which could be modified slightly to guide the adoption of new technology and technique in the twenty-first century. Harvey might suggest (1) careful and accurate observation and description of a new technique, (2) a tentative explanation of how the technique improves on existing techniques, (3) a controlled testing of the hypothesis, and (4) conclusions based on the results of the experiments. Also, he might admonish surgery today, with its massively enhanced capabilities for information management, to rigorously test the validity of these conclusions with quantitative reasoning. In the future, precise measurement of the "trauma" of surgery, or even an individual surgeon, may be possible, and the long-term impact of a chest wall incision on a patient's self-esteem may be predictable. Absent such objective measures, justifications for "minimally invasive" deviations from conventional technique in surgery for CHD lack substance. Morbidity, mortality, and physiological endpoints will continue to form the foundation for therapeutic plans; however, the potential for emerging technology to reduce the trauma of these plans remains tantalizing.
Collapse
Affiliation(s)
- R P Burke
- Division of Cardiovascular Surgery, Miami Children's Hospital, FL 33155-4069, USA.
| | | |
Collapse
|
14
|
Slim R, Forichon J, Boulez J, Mion F. Laparoscopic fundoplication for gastroesophageal reflux: effects on esophageal motility. Surg Laparosc Endosc Percutan Tech 2000; 10:115-9. [PMID: 10872971 DOI: 10.1097/00019509-200006000-00001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Laparoscopic Nissen-Rossetti fundoplication is now recognized as a valid therapy for the treatment of gastroesophageal reflux disease. This retrospective study evaluates the effects of laparoscopic fundoplication on esophageal motility and correlates these effects to postsurgical symptoms. A total of 123 patients underwent laparoscopic fundoplication at our institution. Pre- and postoperative esophageal manometric data were analyzed with regard to the effect of surgery and postsurgical outcome. Postoperative lower esophageal sphincter pressure was significantly increased compared wtih preoperative values (1.7 +/- 0.8 kPa vs 0.9 +/- 0.7 kPa). Duration and amplitude of esophageal body contractions were not modified. The percentage of deglutition-induced complete peristaltic waves and the velocity of propagation were significantly decreased after surgery (P < 0.05). Postoperative symptoms were significantly correlated with postoperative lower esophageal sphincter pressure only. Laparoscopic fundoplication significantly increases lower esophageal sphincter pressure. It significantly decreases esophageal body peristaltic efficiency, a decrease that is most likely of minor clinical significance.
Collapse
Affiliation(s)
- R Slim
- Fédération des Spécialités Digestives, Hôpital E. Herriot, Lyon, France
| | | | | | | |
Collapse
|
15
|
Laparoscopic Fundoplication for Gastroesophageal Reflux: Effects on Esophageal Motility. Surg Laparosc Endosc Percutan Tech 2000. [DOI: 10.1097/00129689-200006000-00001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
16
|
|
17
|
Janorkar S, Goh T, Wilkinson J. Transcatheter closure of patent ductus arteriosus with the use of Rashkind occluders and/or Gianturco coils: long-term follow-up in 123 patients and special reference to comparison, residual shunts, complications, and technique. Am Heart J 1999; 138:1176-83. [PMID: 10577450 DOI: 10.1016/s0002-8703(99)70085-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND This report describes the long-term follow-up of transcatheter closure of patent ductus arteriosus (PDA) with 2 different modalities in 123 patients of diverse ages. METHODS AND RESULTS Between October 1990 and August 1997, 123 patients underwent transcatheter PDA (1.9 to 7.5 mm) closure at a mean age of 6.8 +/- 8.9 years (range 0.06 to 52) and mean weight of 20.9 +/- 17. 6 kg (range 2.7 to 83). In the initial procedure, the Rashkind device was used in 60, the Gianturco coil(s) in 60, and the Rashkind device with a coil in 3 patients. Six-month closure rate for the Rashkind group was 77% versus 90% for the coil group. The second procedure was carried out for residual shunt in 19 (14 in the Rashkind group and 5 in the coil group) and a third procedure in 1 patient from the Rashkind group. A balloon wedge catheter was used in 50 of 78 coil procedures to prevent coil embolization. One device and 11 coils (8 without balloon aid) embolized to the pulmonary arteries. The device and all coils except 2 were retrieved successfully. Overall, 122 (99%) patients showed complete PDA closure. The mean uneventful follow-up period was 44.11 +/- 23.77 months (range 8.7 to 90.28). CONCLUSIONS Transcatheter closure of PDA is feasible in infants as well as in patients >50 years of age without significant complications. The coils are easy to implant, less expensive, and multiple coils may be used in moderately large (>3.5 mm) ducts more effectively than with the Rashkind device. The use of a balloon wedge catheter prevents immediate coil embolization. Multiple procedures are feasible and safe to achieve complete closure.
Collapse
Affiliation(s)
- S Janorkar
- Department of Cardiology, Royal Children's Hospital, Melbourne, Victoria, Australia
| | | | | |
Collapse
|