• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4607196)   Today's Articles (7809)   Subscriber (49373)
For: Tucker RD, Silvis SE. Induced current on the guide wire during sphincterotomy. Gastrointest Endosc 1989;35:45-7. [PMID: 2920884 DOI: 10.1016/s0016-5107(89)72685-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Number Cited by Other Article(s)
1
Kobayashi M, Katsuda H, Ohtsuka K, Okamoto R. Comparison of guidewires for successful cannulation of biliary stenosis and targeting of biliary branches in ERCP. Endosc Int Open 2023;11:E805-E810. [PMID: 37664788 PMCID: PMC10473887 DOI: 10.1055/a-2131-5145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 07/10/2023] [Indexed: 09/05/2023]  Open
2
Somogyi L, Chuttani R, Croffie J, Disario J, Liu J, Mishkin D, Shah R, Tierney W, Wong Kee Song LM, Petersen BT. Guidewires for use in GI endoscopy. Gastrointest Endosc 2007;65:571-6. [PMID: 17383455 DOI: 10.1016/j.gie.2006.10.003] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
3
Ratani RS, Mills TN, Ainley CC, Swain CP. Electrophysical factors influencing endoscopic sphincterotomy. Gastrointest Endosc 1999;49:43-52. [PMID: 9869722 DOI: 10.1016/s0016-5107(99)70444-x] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
4
O'Brien JW, Chen SL, Connolly R, Libby ED. Current induction in a fiberglass guidewire compared to conventional wires during simulated papillotomy. Gastrointest Endosc 1997;45:493-7. [PMID: 9199907 DOI: 10.1016/s0016-5107(97)70200-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
5
Jacob L, Geenen JE. ERCP guide wires. Gastrointest Endosc 1996;43:57-60. [PMID: 8903820 DOI: 10.1016/s0016-5107(96)70262-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
6
Sisken RB, Fearnot NE, Smith HJ. Electrosurgical safety of guide wires during endoscopic sphincterotomy. Gastrointest Endosc 1993;39:770-3. [PMID: 8293899 DOI: 10.1016/s0016-5107(93)70262-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
7
Johlin FC, Tucker RD, Ferguson S. The effect of guidewires during electrosurgical sphincterotomy. Gastrointest Endosc 1992;38:536-40. [PMID: 1397906 DOI: 10.1016/s0016-5107(92)70511-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
8
Subei IN, Bassiony H. A combined percutaneous endoscopic placement of biliary stent for malignant obstructive jaundice: "A few practical hints make it safe". Ann Saudi Med 1991;11:707-11. [PMID: 17590829 DOI: 10.5144/0256-4947.1991.707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]  Open
9
Sherman S, Hawes RH, Lehman GA. A new approach to performing endoscopic sphincterotomy in the setting of a juxtapapillary duodenal diverticulum. Gastrointest Endosc 1991;37:353-5. [PMID: 1906414 DOI: 10.1016/s0016-5107(91)70730-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
10
Schoenfeld PS, Jones DM, Lawson JM. Conducted current on guidewires in single lumen papillotomes. Gastrointest Endosc 1991;37:344-6. [PMID: 2070986 DOI: 10.1016/s0016-5107(91)70728-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
11
Tucker RD, Sievert CE, Vennes JA, Silvis SE. Endoscopic radio frequency electrosurgery. Gastrointest Endosc 1990;36:412-3. [PMID: 2210292 DOI: 10.1016/s0016-5107(90)71082-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA