1
|
Li H, Anjani QK, McGuckin MB, Himawan A, Li M, Donnelly RF. Development of a HPLC fluorometric method for the quantification of enfuvirtide following in vitro releasing studies on thermosensitive in situ forming gel. Drug Deliv Transl Res 2023:10.1007/s13346-023-01344-5. [PMID: 37120679 DOI: 10.1007/s13346-023-01344-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/30/2023] [Indexed: 05/01/2023]
Abstract
Due to the presence of peptidase and protease in the gastrointestinal tract, peptides are subjected to digestion and inactivation when administrated orally. To avoid degradation and maintain the desired efficacy of peptide drugs, there is a demand to develop transdermal and intradermal delivery systems. This requires efficient and specific analytical methods to separate and quantify the peptide drugs from the formulation and the skin matrix in the early stages of pharmaceutical development. A high-performance liquid chromatography (HPLC) system equipped with a fluorometric detector was used to quantify enfuvirtide, which is the first fusion inhibitor for HIV treatment. The HPLC method was developed and validated according to the ICH Q2(R1) guidelines. The viability of the method was demonstrated during in vitro studies, where samples were analysed following intradermal administration of a thermosensitive in situ forming gel. Compared with previously reported methods, this assay proved efficient, sensitive and accurate, with a detection limit of 0.74 μg/mL and a run time of 9 min, mitigating the use of any internal standards and detergents. The addition of an organic solvent to the samples successfully solved the problem of low recovery caused by the adsorption of the drug to the plastic consumables in the sample treatment process. The amount of enfuvirtide releasing from the in situ gel through skin after 7 hours was 16.25 ± 7.08 μg, which was significantly lower than the reconstituted FUZEON® itself (26.68 ± 10.45 μg), showing a longer release profile. The results may be beneficial as a constructive input for future enfuvirtide quantification within a preclinical setting through in vitro release studies across the skin.
Collapse
Affiliation(s)
- Huanhuan Li
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Qonita Kurnia Anjani
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK
- Fakultas Farmasi, Universitas Megarezky, Jl. Antang Raya No. 43, Makassar, 90234, Indonesia
| | - Mary B McGuckin
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Achmad Himawan
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK
- Department of Pharmaceutical Science and Technology, Faculty of Pharmacy, Universitas Hasanuddin, Makassar, 90245, Indonesia
| | - Mingshan Li
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK.
| |
Collapse
|
2
|
Kovacs JM, Mant CT, Kwok SC, Osguthorpe DJ, Hodges RS. Quantitation of the nearest-neighbour effects of amino acid side-chains that restrict conformational freedom of the polypeptide chain using reversed-phase liquid chromatography of synthetic model peptides with L- and D-amino acid substitutions. J Chromatogr A 2006; 1123:212-24. [PMID: 16712857 PMCID: PMC1976429 DOI: 10.1016/j.chroma.2006.04.092] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2005] [Revised: 04/18/2006] [Accepted: 04/28/2006] [Indexed: 10/24/2022]
Abstract
Side-chain backbone interactions (or "effects") between nearest neighbours may severely restrict the conformations accessible to a polypeptide chain and thus represent the first step in protein folding. We have quantified nearest-neighbour effects (i to i+1) in peptides through reversed-phase liquid chromatography (RP-HPLC) of model synthetic peptides, where L- and D-amino acids were substituted at the N-terminal end of the peptide sequence, adjacent to a L-Leu residue. These nearest-neighbour effects (expressed as the difference in retention times of L- and D-peptide diastereomers at pHs 2 and 7) were frequently dramatic, depending on the type of side-chain adjacent to the L-Leu residue, albeit such effects were independent of mobile phase conditions. No nearest-neighbour effects were observed when residue i is adjacent to a Gly residue. Calculation of minimum energy conformations of selected peptides supported the view that, whether a L- or D-amino acid is substituted adjacent to L-Leu, its orientation relative to this bulky Leu side-chain represents the most energetically favourable configuration. We believe that such energetically favourable, and different, configurations of L- and D-peptide diastereomers affect their respective interactions with a hydrophobic stationary phase, which are thus quantified by different RP-HPLC retention times. Side-chain hydrophilicity/hydrophobicity coefficients were generated in the presence of these nearest-neighbour effects and, despite the relative difference in such coefficients generated from peptides substituted with L- or D-amino acids, the relative difference in hydrophilicity/hydrophobicity between different amino acids in the L- or D-series is maintained. Overall, our results demonstrate that such nearest-neighbour effects can clearly restrict conformational space of an amino acid side-chain in a polypeptide chain.
Collapse
Affiliation(s)
- James M Kovacs
- Department of Biochemistry and Molecular Genetics, University of Colorado at Denver and Health Sciences Center, Aurora, CO 80045, USA
| | | | | | | | | |
Collapse
|
3
|
D'Avolio A, Sciandra M, de Requena DG, Ibañez A, Bonora S, Di Perri G. An Improved HPLC Fluorimetric Method for the Determination of Enfuvirtide Plasma Levels in HIV-Infected Patients. Ther Drug Monit 2006; 28:110-5. [PMID: 16418704 DOI: 10.1097/01.ftd.0000179421.25337.62] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
An improved HPLC fluorimetric method for the quantification of enfuvirtide in plasma of HIV-infected subjects was described and validated. The use of an internal standard improved the reproducibility and precision of the analysis. Our method showed lower limits of detection and quantification (LOD = 32 ng/mL, LOQ = 78 ng/mL), lower intraday (RSD% 1.25-2.95) and interday (RSD% 1.75-4.69) coefficients of variation, greater recovery (>100%), lower duration (16 minutes) and lower cost than previously described fluorimetric methods. Therefore, this method can be used as a reliable tool for pharmacokinetic studies of enfuvirtide.
Collapse
Affiliation(s)
- Antonio D'Avolio
- Department of Infectious Diseases, University of Torino, Amedeo di Savoia Hospital, Turin, Italy.
| | | | | | | | | | | |
Collapse
|
4
|
Shibue M, Mant C, Hodges R. The perchlorate anion is more effective than the trifluoroacetate anion as an ion-pairing reagent for reversed-phase chromatography of peptides. J Chromatogr A 2005; 1080:49-57. [PMID: 16013614 PMCID: PMC2722116 DOI: 10.1016/j.chroma.2005.02.063] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The addition of salts, specifically sodium perchlorate (NaClO4), to mobile phases at acidic pH as ion-pairing reagents for reversed-phase high-performance liquid chromatography (RP-HPLC) has been generally overlooked. To demonstrate the potential of NaClO4 as an effective anionic ion-pairing reagent, we applied RP-HPLC in the presence of 0-100 mM sodium chloride (NaCl), sodium trifluoroacetate (NaTFA) or NaClO4 to two mixtures of synthetic 18-residue peptides: a mixture of peptides with the same net positive charge (+4) and a mixture of four peptides of +1, +2, +3 and +4 net charge. Interestingly, the effect of increasing NaClO4 concentration on increasing peptide retention times and selectivity changes was more dramatic than that of either NaCl or NaTFA, with the order of increasing anion effectiveness being Cl- << TFA- < C104-. Such effects were more marked when salt addition was applied to eluents containing 10 mM phosphoric acid (H3PO4) compared to 10 mM trifluoroacetic acid (TFA) due to the lesser starting anion hydrophobicity of the former mobile phase (containing the phosphate ion) compared to the latter (containing the TFA- ion).
Collapse
Affiliation(s)
| | | | - R.S. Hodges
- Corresponding author. Tel.: +1 303 724 3253; fax: +1 303 724 3249., E-mail address: (R.S. Hodges)
| |
Collapse
|
5
|
Sereda TJ, Mant CT, Hodges RS. Use of sodium perchlorate at low pH for peptide separations by reversed-phase liquid chromatography. Influence of perchlorate ion on apparent hydrophilicity of positively charged amino acid side-chains. J Chromatogr A 1997; 776:153-65. [PMID: 9286089 DOI: 10.1016/s0021-9673(97)00150-7] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The reversed-phase liquid chromatography (RPLC) behavior of synthetic model peptides containing positively charged amino acid residues was studied in the presence or absence of 100 mM sodium perchlorate in order to determine the effect on apparent side-chain hydrophilicity of a charged residue at low pH. The peptides used in this study were either non-helical peptides or amphipathic alpha-helical peptides, where the effect of the negatively charged perchlorate ion on a charged residue in either the hydrophobic face or hydrophilic face of the helix was monitored. We have shown that the addition of 100 mM perchlorate to RPLC separations of positively charged peptides performed in a 20 mM aqueous phosphoric acid-acetonitrile system resulted in an increase in retention time of a peptide relative to the same peptide in the absence of perchlorate. This effect occurred independent of conformation, i.e., whether comparing the effect of positively charged residue substitutions in the hydrophobic or hydrophilic face of an amphipathic alpha-helix or in a peptide with negligible secondary structure. From these results, suggesting that positively charged side-chain hydrophilicity is decreased by ion-pairing with the perchlorate ion, we have shown practical examples where mixtures of non-helical and amphipathic alpha-helical peptides showed enhanced resolution in the presence of perchlorate at pH 2, compared to in its absence. In addition, it was shown that an aqueous phosphoric acid-perchlorate-acetonitrile mobile phase may show markedly different selectivity for peptide separations at low pH compared to the more traditional aqueous trifluoroacetic acid-acetonitrile system.
Collapse
Affiliation(s)
- T J Sereda
- Department of Biochemistry, University of Alberta, Edmonton, Canada
| | | | | |
Collapse
|
6
|
Linde S, Welinder BS, Nielsen JH. Analysis of proinsulin and its conversion products by reversed-phase high-performance liquid chromatography. JOURNAL OF CHROMATOGRAPHY 1993; 614:185-204. [PMID: 8314931 DOI: 10.1016/0378-4347(93)80309-r] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Proinsulin is synthesized in the beta-cells of the endocrine pancreas, one of the four cell types found in the islets of Langerhans. Specific enzymatic cleavage of proinsulin results in the formation of equimolar amounts of insulin and C-peptide, via several intermediate split-proinsulin forms. Most mammals produce a single insulin, but in rodents two non-allelic insulin genes are expressed. There is an inverse ratio between the two insulins in rats and mice, the reason for this being unknown. It has been suggested that differences in transcription, translation (biosynthesis) and/or posttranslational processes (enzymatic conversion, intracellular degradation) could be possible explanations. Elevated amounts of proinsulin-immunoreactive material (PIM) have been described to occur in various conditions/diseases, suggesting alterations in beta-cell function, but the composition of the secreted PIM (intact proinsulin or its intermediates) has been incompletely determined. Studies of the biosynthesis of proinsulins and their conversion with the purpose of revealing some of these points depend on accessible reversed-phase high-performance liquid chromatographic (RP-HPLC) analyses capable of separating all the relevant, closely related polypeptides involved. This review will deal with the optimization of the RP-HPLC separations as well as sample preparation and recovery. Applications of the selected methods in the study of proinsulin biosynthesis and its conversion will also be presented.
Collapse
Affiliation(s)
- S Linde
- Immunochemical Department, Novo Nordisk A/S, Bagsvaerd, Denmark
| | | | | |
Collapse
|
7
|
de Frutos M, Cifuentes A, Amigo L, Ramos M, Diez-Masa JC. Rapid analysis of whey proteins from different animal species by reversed-phase high-performance liquid chromatography. ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND -FORSCHUNG 1992; 195:326-31. [PMID: 1441761 DOI: 10.1007/bf01187908] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
This paper explores the possibilities of reversed-phase high performance liquid chromatography (RP-HPLC) for analysing whey proteins from the milk of cows and other animal species. An RP-HPLC method is proposed to separate and quantify bovine whey proteins. Using this method, bovine serum albumin, alpha-lactalbumin, beta-lactoglobulin A and beta-lactoglobulin B were separated in less than 7 min. It is demonstrated that irreversible adsorption of bovine whey proteins occurs on unused columns (i.e. those not previously used to separate proteins). Therefore, prior conditioning of the column with whey proteins is required for valid protein quantification. Conditioning can be achieved by eluting a large amount of at least one of the bovine whey proteins through the unused column. The calibration curve (peak area vs. protein concentration) for the main bovine whey proteins was linear. This method also allowed good separation of caprine and ovine whey proteins and separation of some homologous whey proteins of different animal species. Detection of milk mixtures from different animal species was carried out using this method.
Collapse
Affiliation(s)
- M de Frutos
- Instituto de Química Orgánica General, Consejo Superior de Investigaciones Científicas, Juan de la Cierva, Madrid, Spain
| | | | | | | | | |
Collapse
|
8
|
Welinder BS. Use of polymeric reversed-phase columns for the characterization of polypeptides extracted from human pancreata. II. Effect of the stationary phase. J Chromatogr A 1991; 542:83-99. [PMID: 1874841 DOI: 10.1016/s0021-9673(01)88750-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The potential value of eight commercial available polymer-based reversed-phase (RP) columns for peptide and protein separations was evaluated using crude acetic acid extracts of normal and diabetic human pancreata and mixtures of pure polypeptides as samples. All columns were characterized with acetic acid gradients in water as mobile phase, and different chromatographic profiles were obtained depending on the type of polymer column (bare or derivatized) and the type of ligand. Some of the columns were virtually free from effects related to the polymer skeleton whereas in others the separation was influenced by both the ligand and the polymeric backbone. Two selected polymeric RP columns were, together with a silica-based C4 column, further characterized with acetonitrile gradients in trifluoroacetic acid (TFA), and the separation temperature was found to have a drastic effect on the separation efficiency for proteins with mol. wt. greater than 6000 dalton. No such effect was seen for polypeptides with mol. wt. less than 6000 dalton. Mixtures of pure peptides and proteins were separated using acetic acid gradients in water, acetonitrile or isopropanol, and normally the highest efficiency was found with the use of acetonitrile as mobile phase modifier. Isopropanol was less suitable as an organic modifier. The separation of the beta-lactoglobulin A- and B-chains may be used to give a rapid estimate of the chromatographic usability of polymer-based RP-columns for peptide and protein separations in acetic acid gradients in water and in acetonitrile gradients. Recoveries for insulin, proinsulin, growth hormone, ovalbumin and human serum albumin were measured for several polymer-based RP columns eluted with acetic acid gradients in water and with acetonitrile-based mobile phases. The highest recoveries of serum albumin and ovalbumin were found after elution with acetic acid gradients in water.
Collapse
|
9
|
Larsson K, Hermann W, Möller P, Sanchez D. Preparative high-performance liquid chromatography of peptides on a new reversed-phase packing material, Kromasil C18. J Chromatogr A 1988; 450:71-80. [PMID: 2906065 DOI: 10.1016/s0021-9673(00)90716-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Preparative reversed-phase high-performance liquid chromatography has found wide use in the production of peptides for pharmaceutical formulations. Purity of the substance and overall economy of the chromatographic system are the most important criterias. In this sense optimized, silica particles and production process with capability to separately control parameters important to chromatography, are essential to high-performance chromatography. Kromasil C18 packing material was tested and evaluated in respect of its selectivity, flow and pressure properties, resolution, load capacity, recovery, adsorption effects, mechanical strength and chemical degradation.
Collapse
Affiliation(s)
- K Larsson
- Ferring Pharmaceuticals, Malmö, Sweden
| | | | | | | |
Collapse
|
10
|
Foucault A, Nakanishi K. Study of AcOH/HCOOH/H2O/CHCL3Solvent System Application to the Separation of Two Large and Hydrophobic Fragments of Bacteriorhodopsin Membrane Protein by Centrifugal Partition Chromatography. ACTA ACUST UNITED AC 1988. [DOI: 10.1080/01483918808076740] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|