1
|
Potential and Scale-Up of Pore-Through-Flow Membrane Reactors for the Production of Prebiotic Galacto-Oligosaccharides with Immobilized β-Galactosidase. Catalysts 2021. [DOI: 10.3390/catal12010007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The production of prebiotics like galacto-oligosaccharides (GOS) on industrial scale is becoming more important due to increased demand. GOS are synthesized in batch reactors from bovine lactose using the cost intensive enzyme β-galactosidase (β-gal). Thus, the development of sustainable and more efficient production strategies, like enzyme immobilization in membrane reactors are a promising option. Activated methacrylatic monoliths were characterized as support for covalent immobilized β-gal to produce GOS. The macroporous monoliths act as immobilized pore-through-flow membrane reactors (PTFR) and reduce the influence of mass-transfer limitations by a dominating convective pore flow. Monolithic designs in the form of disks (0.34 mL) and for scale-up cylindric columns (1, 8 and 80 mL) in three different reactor operation configurations (semi-continuous, continuous and continuous with recirculation) were studied experimentally and compared to the free enzyme system. Kinetic data, immobilization efficiency, space-time-yield and long-term stability were determined for the immobilized enzyme. Furthermore, simulation studies were conducted to identify optimal operation conditions for further scale-up. Thus, the GOS yield could be increased by up to 60% in the immobilized PTFRs in semi-continuous operation compared to the free enzyme system. The enzyme activity and long-time stability was studied for more than nine months of intensive use.
Collapse
|
2
|
Staniak M, Wójciak M, Sowa I, Tyszczuk-Rotko K, Strzemski M, Dresler S, Myśliński W. Silica-Based Monolithic Columns as a Tool in HPLC-An Overview of Application in Analysis of Active Compounds in Biological Samples. Molecules 2020; 25:molecules25143149. [PMID: 32660127 PMCID: PMC7397265 DOI: 10.3390/molecules25143149] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 07/02/2020] [Accepted: 07/06/2020] [Indexed: 01/08/2023] Open
Abstract
Monolithic fillings used in chromatography are of great interest among scientists since the first reports of their synthesis and use were published. In the 20 years since silica-based monolithic columns were introduced into the commercial market, numerous papers describing their chromatographical properties and utility in various branches of industry and scientific investigations were presented. This review is focused on possible applications of commercially available silica-based HPLC monolithic columns in the analysis of biological samples.
Collapse
Affiliation(s)
- Michał Staniak
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
- Correspondence: (M.S.); (M.W.)
| | - Magdalena Wójciak
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
- Correspondence: (M.S.); (M.W.)
| | - Ireneusz Sowa
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
| | - Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University Lublin, 20-031 Lublin, Poland;
| | - Maciej Strzemski
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
| | - Sławomir Dresler
- Department of Plant Physiology and Biophysics, Maria Curie-Skłodowska University, 20-033 Lublin, Poland;
| | - Wojciech Myśliński
- Chair and Department of Internal Diseases, Medical University of Lublin, 20-081 Lublin, Poland;
| |
Collapse
|
3
|
Vlakh EG, Korzhikov VA, Hubina AV, Tennikova TB. Molecular imprinting: a tool of modern chemistry for the preparation of highly selective monolithic sorbents. RUSSIAN CHEMICAL REVIEWS 2015. [DOI: 10.1070/rcr4501] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
4
|
Jespersen GR, Nielsen AL, Matthiesen F, Andersen HS, Kirsebom H. Dual application of cryogel as solid support in peptide synthesis and subsequent protein-capture. J Appl Polym Sci 2013. [DOI: 10.1002/app.39727] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
| | - Anders Laerke Nielsen
- Novo Nordisk A/S; Department of Biopharm Chemistry; Novo Nordisk Park; DK-2760; Måløv; Denmark
| | - Finn Matthiesen
- Novo Nordisk A/S; Department of Protein Purification Technology; Novo Nordisk Park; DK-2760; Måløv; Denmark
| | - Henrik Sune Andersen
- Novo Nordisk A/S; Department of Biopharm Chemistry; Novo Nordisk Park; DK-2760; Måløv; Denmark
| | - Harald Kirsebom
- Department of Biotechnology; Lund University; 221 00; Lund; Sweden
| |
Collapse
|
5
|
Sousa Â, Sousa F, Queiroz JA. Advances in chromatographic supports for pharmaceutical-grade plasmid DNA purification. J Sep Sci 2012; 35:3046-58. [DOI: 10.1002/jssc.201200307] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2012] [Revised: 05/28/2012] [Accepted: 06/02/2012] [Indexed: 01/04/2023]
Affiliation(s)
- Ângela Sousa
- CICS-UBI - Centro de Investigação em Ciências da Saúde; Universidade da Beira Interior; Covilhã Portugal
| | - Fani Sousa
- CICS-UBI - Centro de Investigação em Ciências da Saúde; Universidade da Beira Interior; Covilhã Portugal
| | - João A. Queiroz
- CICS-UBI - Centro de Investigação em Ciências da Saúde; Universidade da Beira Interior; Covilhã Portugal
| |
Collapse
|
6
|
Smrekar F, Ciringer M, Jančar J, Raspor P, Štrancar A, Podgornik A. Optimization of lytic phage manufacturing in bioreactor using monolithic supports. J Sep Sci 2011; 34:2152-8. [DOI: 10.1002/jssc.201100182] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2011] [Revised: 04/17/2011] [Accepted: 04/18/2011] [Indexed: 12/12/2022]
|
7
|
Brgles M, Clifton J, Walsh R, Huang F, Rucevic M, Cao L, Hixson D, Müller E, Josic D. Selectivity of monolithic supports under overloading conditions and their use for separation of human plasma and isolation of low abundance proteins. J Chromatogr A 2010; 1218:2389-95. [PMID: 21186030 DOI: 10.1016/j.chroma.2010.11.059] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2010] [Revised: 10/19/2010] [Accepted: 11/25/2010] [Indexed: 01/06/2023]
Abstract
Human serum albumin (HSA) and immunoglobulin G (IgG) represent over 75% of all proteins present in human plasma. These two proteins frequently interfere with detection, determination and purification of low abundance proteins that can be potential biomarkers and biomarker candidates for various diseases. Some low abundance plasma proteins such as clotting factors and inhibitors are also important therapeutic agents. In this paper, the characterization of ion-exchange monolithic supports under overloading conditions was performed by use of sample displacement chromatography (SDC). If these supports were used for separation of human plasma, the composition of bound and eluted proteins in both anion- and cation-exchange mode is dependent on column loading. Under overloading conditions, the weakly bound proteins such as HSA in anion-exchange and IgG in cation-exchange mode are displaced by stronger binding proteins, and this phenomenon was not dependent on column size. Consequently, small monolithic columns with a column volume of 100 and 200 μL are ideal supports for high-throughput screening in order to develop new methods for separation of complex mixtures, and for sample preparation in proteomic technology.
Collapse
|
8
|
Applications of polymethacrylate-based monoliths in high-performance liquid chromatography. J Chromatogr A 2008; 1216:2637-50. [PMID: 18929365 DOI: 10.1016/j.chroma.2008.09.090] [Citation(s) in RCA: 103] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2008] [Revised: 09/22/2008] [Accepted: 09/25/2008] [Indexed: 11/23/2022]
Abstract
Monolithic columns were introduced in the early 1990s and have become increasingly popular as efficient stationary phases for most of the important chromatographic separation modes. Monoliths are functionally distinct from porous particle-based media in their reliance on convective mass transport. This makes resolution and capacity independent of flow rate. Monoliths also lack a void volume. This eliminates eddy dispersion and permits high-resolution separations with extremely short flow paths. The analytical value of these features is the subject of recent reviews. Nowadays, among other types of rigid macroporous monoliths, the polymethacrylate-based materials are the largest and most examined class of these sorbents. In this review, the applications of polymethacrylate-based monolithic columns are summarized for the separation, purification and analysis of low and high molecular mass compounds in the different HPLC formats, including micro- and large-scale HPLC modes.
Collapse
|
9
|
Barut M, Podgornik A, Urbas L, Gabor B, Brne P, Vidic J, Plevcak S, Strancar A. Methacrylate-based short monolithic columns: enabling tools for rapid and efficient analyses of biomolecules and nanoparticles. J Sep Sci 2008; 31:1867-80. [PMID: 18615813 DOI: 10.1002/jssc.200800189] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
This review describes the novel chromatography stationary phase--a porous monolithic methacrylate-based polymer--in terms of the design of the columns and some of the features that make these columns attractive for the purification of large biomolecules. We first start with a brief summary of the characteristics of these large molecules (more precisely large proteins like immunoglobulins G and M, plasmid deoxyribonucleic acid (DNA), and viral particles), and a list of some of the problems that were encountered during the development of efficient purification processes. We then briefly describe the structure of the methacrylate-based monolith and emphasize the features which make them more than suitable for dealing with large entities. The highly efficient structure on a small scale can be transferred to a large scale without the need of making column modifications, and the various approaches of how this is accomplished are briefly presented in this paper. This is followed by presenting some of the examples from the bioprocess development schemes, where the implementation of the methacrylate-based monolithic columns has resulted in a very efficient and productive process. Following this, we move back to the analytical scale and demonstrate the efficiency of the monolithic column--where the mass transfer between the stationary and mobile phase is greatly enhanced--for the in-process and final control of the new therapeutics. The combination of an efficient structure and the appropriate hardware results in separations of proteins with residence time less than 0.1 s.
Collapse
Affiliation(s)
- Milos Barut
- BIA Separations, Teslova 30, Ljubljana, Slovenia.
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Kovac S, Yang X, Huang F, Hixson D, Josic D. Proteomics as a tool for optimization of human plasma protein separation. J Chromatogr A 2008; 1194:38-47. [PMID: 18486944 DOI: 10.1016/j.chroma.2008.04.026] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2007] [Revised: 04/08/2008] [Accepted: 04/10/2008] [Indexed: 01/05/2023]
Abstract
The application of proteomics technology in purification of proteins from human plasma and for characterization of plasma-derived therapeutics has been recently discussed. However, until now, the impact of this technology on the plasma protein fractionation and analysis of the final product has not been realized. In the present work, we demonstrate the use of proteomic techniques the monitoring of the first step of the plasma fractionation by use of anion-exchange chromatography. This chromatographic method is frequently used in the purification scheme for isolation of vitamin K dependent clotting factors II, VII, IX and X, and clotting inhibitors protein C and protein S, as well as inter-alpha inhibitor proteins (IaIp). After the removal of immunoglobulin G and non-binding proteins in the flow-through fraction, albumin and weakly bound proteins were eluted with low concentration of sodium chloride. The proteins that strongly bind to the anion-exchange column were eluted by higher salt concentrations. The fractions of interest were analyzed, and proteins were identified by LC-ESI-MS/MS. By use of this method, not only candidates for therapeutic concentrates, but also some potentially harmful components were identified. This strategy was very helpful for further process optimization, fast identification of target proteins with relatively low abundance, and for the design of subsequent steps in their removal or purification.
Collapse
Affiliation(s)
- Spomenka Kovac
- J.J. Strossmayer University of Osijek, Department of Chemistry, HR-31000 Osijek, Croatia
| | | | | | | | | |
Collapse
|
11
|
Jungbauer A, Hahn R. Polymethacrylate monoliths for preparative and industrial separation of biomolecular assemblies. J Chromatogr A 2008; 1184:62-79. [DOI: 10.1016/j.chroma.2007.12.087] [Citation(s) in RCA: 182] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2007] [Revised: 12/04/2007] [Accepted: 12/19/2007] [Indexed: 11/28/2022]
|
12
|
Danquah MK, Ho J, Forde GM. A thermal expulsion approach to homogeneous large-volume methacrylate monolith preparation; Enabling large-scale rapid purification of biomolecules. J Appl Polym Sci 2008. [DOI: 10.1002/app.28346] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
13
|
Bencina K, Bencina M, Podgornik A, Strancar A. Influence of the methacrylate monolith structure on genomic DNA mechanical degradation, enzymes activity and clogging. J Chromatogr A 2007; 1160:176-83. [PMID: 17540390 DOI: 10.1016/j.chroma.2007.05.034] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2006] [Revised: 04/12/2007] [Accepted: 05/10/2007] [Indexed: 10/23/2022]
Abstract
The chromatography of mechanically sensitive macromolecules still represents a challenge. While larger pores can reduce the mechanically induced cleavage of large macromolecules and column clogging, the column performance inevitably decreases. To investigate the effect of pore size on the mechanical degradation of DNA, column permeability and enzyme biological activity, methacrylate monoliths with different pore sizes were tested. Monolith with a 143 nm pore radius mechanically damaged the DNA and was clogged at flow rates above 0.5 ml min(-1) (26 cm h(-1)). For monoliths with a pore radius of 634 nm and 2900 nm, no mechanical degradation of DNA was observed up to 5 ml min(-1) (265 cm h(-1)) above which the HPLC itself became the main source of damage. A decrease of a permeability appeared at flow rate 1.8 ml min(-1) (95 cm h(-1)) and 2.3 ml min(-1) (122 cm h(-1)), respectively. The effect of the pore size on enzyme biological activity was tested with immobilized DNase and trypsin on all three monoliths. Although the highest amount of enzyme was immobilized on the monolith with the smallest pores, monolith with the pore radius 634 nm exhibited the highest DNase biological activity probably due to restricted access for DNA molecules into the small pores. Interestingly, specific biological activity was increasing with a pore size decrease. This was attributed to higher number of contacts between a substrate and immobilized ligand.
Collapse
Affiliation(s)
- Katja Bencina
- BIA separations d.o.o., Teslova 30, SI-1001 Ljubljana, Slovenia
| | | | | | | |
Collapse
|
14
|
|
15
|
Merhar M, Podgornik A, Barut M, Jakša S, Zigon M, Štrancar A. HIGH PERFORMANCE REVERSED-PHASE LIQUID CHROMATOGRAPHY USING NOVEL CIM RP-SDVB MONOLITHIC SUPPORTS. J LIQ CHROMATOGR R T 2006. [DOI: 10.1081/jlc-100105949] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
| | | | | | - S. Jakša
- a National Institute of Chemistry , Hajdrihova 19, Ljubljana, Slovenia, SI-1000
| | - M. Zigon
- a National Institute of Chemistry , Hajdrihova 19, Ljubljana, Slovenia, SI-1000
| | | |
Collapse
|
16
|
Barut M, Podgornik A, Brne P, Strancar A. Convective interaction media short monolithic columns: enabling chromatographic supports for the separation and purification of large biomolecules. J Sep Sci 2006; 28:1876-92. [PMID: 16276780 DOI: 10.1002/jssc.200500246] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
New therapeutics that are being developed rely more and more on large and complex biomacromolecules like proteins, DNA, and viral particles. Manufacturing processes are being redesigned and optimized both upstream and downstream to cope with the ever-increasing demand for the above target molecules. In downstream processing, LC still represents the most powerful technique for achieving high yield and high purities of these molecules. In most cases, however, the separation technology relies on conventional particle-based technology, which has been optimized for the purification of smaller molecules. New technologies are, therefore, needed in order to push the downstream processing ahead and into the direction that will provide robust, productive, and easy to implement methods for the production of novel therapeutics. New technologies include the renaissance of membranes, various improvements of existing technologies, but also the introduction of a novel concept--the continuous bed or monolithic stationary phases. Among different introduced products, Convective Interaction Media short monolithic columns (SMC) that are based on methacrylate monoliths exhibit some interesting features that make them attractive for these tasks. SMC can be initially used for fast method development on the laboratory scale and subsequently efficiently transferred to preparative and even more importantly to industrial scale. A brief historical overview of methacrylate monoliths is presented, followed by a short presentation of theoretical considerations that had led to the development of SMC. The design of these columns, as well as their scale-up to large units, together with the methods for transferring gradient separations from one scale to another are addressed. Noninvasive methods that have been developed for the physical characterization of various batches of SMC, which fulfill the regulatory requirements for cGMP production, are discussed. The applications of SMC for the separation and purification of large biomolecules, which demonstrate the full potential of this novel technology for an efficient downstream processing of biomolecules, are also presented.
Collapse
|
17
|
Arrua RD, Serrano D, Pastrana G, Strumia M, Igarzabal CIA. Synthesis of macroporous polymer rods based on an acrylamide derivative monomer. ACTA ACUST UNITED AC 2006. [DOI: 10.1002/pola.21768] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
18
|
Podgornik A, Vidič J, Jančar J, Lendero N, Frankovič V, Štrancar A. Noninvasive Methods for Characterization of Large-Volume Monolithic Chromatographic Columns. Chem Eng Technol 2005. [DOI: 10.1002/ceat.200500170] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
19
|
Abstract
The history of the development of short monolithic beds is described.
Collapse
Affiliation(s)
- Tatiana B Tennikova
- Institute of Macromolecular Compounds, Russian Academy of Sciences, St Petersburg 199004, Russia.
| | | |
Collapse
|
20
|
Podgornik A, Strancar A. Convective Interaction Media (CIM)--short layer monolithic chromatographic stationary phases. BIOTECHNOLOGY ANNUAL REVIEW 2005; 11:281-333. [PMID: 16216781 DOI: 10.1016/s1387-2656(05)11009-6] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Modern downstream processing requires fast and highly effective methods to obtain large quantities of highly pure substances. Commonly applied method for this purpose is chromatography. However, its main drawback is its throughput since purification, especially of large molecules, requires long process time. To overcome this problem several new stationary phases were introduced, among which short layer monoliths show superior properties for many applications. The purpose of this review is to give an overview about short methacrylate monolithic columns commercialised under the trademark Convective Interaction Media (CIM). Their unique properties are described from different perspectives, explaining reasons for their application on various areas. Approaches to prepare large volume methacrylate monolithic column are discussed and optimal solutions are given. Different examples of CIM monolithic column implementation are summarised in the last part of the article to give the reader an idea about their advantages.
Collapse
Affiliation(s)
- Ales Podgornik
- BIA Separations d.o.o., Teslova 30, SI-1000 Ljubljana, Slovenia.
| | | |
Collapse
|
21
|
Zöchling A, Hahn R, Ahrer K, Urthaler J, Jungbauer A. Mass transfer characteristics of plasmids in monoliths. J Sep Sci 2004; 27:819-27. [PMID: 15354559 DOI: 10.1002/jssc.200401777] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The hydrodynamic properties and pore-structure of monoliths based on functionalized poly(glycidyl methacrylate-ethylene dimethacrylate) were characterised by pulse response experiments using different probes representing a wide range of molecular mass. On a small scale, band spreading was found to be caused to the extent of more than 90% by extra-column effects. These monoliths have large channel diameters, providing a suitable chromatography adsorbent for processing of large molecules. Dynamic and static binding capacity for plasmid DNA was investigated. For our model plasmid, consisting of 4.9 kbp, a capacity of 7 mg/mL was observed in comparison to 0.3 mg/mL for a conventional medium designed for protein separation. When plasmids were loaded on the monolith a gradual increase in pressure drop was observed. The channels filled up and the cross-sectional area available for liquid flow decreased. Therefore, a higher pressure drop was observed during elution. This is caused by (i) shrinking of the channels as effect of the high salt concentration, (ii) high viscosity of the mobile phase due to high concentration of plasmids, and (iii) an increase of the hydrodynamic radius of the plasmid with salt concentration from 45 nm at 150 mM to 70 nm at 2 M NaCl, as measured by dynamic light scattering. These types of monoliths are considered to be the preferred adsorbents for plasmid separation.
Collapse
Affiliation(s)
- Alfred Zöchling
- Institute of Applied Microbiology, University of Natural Resources and Applied Life Sciences, Muthgasse 18, A-1190 Vienna, Austria
| | | | | | | | | |
Collapse
|
22
|
Branovic K, Forcic D, Ivancic J, Strancar A, Barut M, Kosutic Gulija T, Zgorelec R, Mazuran R. Application of short monolithic columns for fast purification of plasmid DNA. J Chromatogr B Analyt Technol Biomed Life Sci 2004; 801:331-7. [PMID: 14751803 DOI: 10.1016/j.jchromb.2003.11.035] [Citation(s) in RCA: 56] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Anion-exchange chromatography is one of the most important methods in downstream processing of plasmid DNA, both as a process and as an analytical technique. Separation of plasmid DNA on traditional particle-based anion-exchange supports is usually slow. Moreover, such supports have a low capacity for plasmid DNA due to the steric exclusion effects. In this work, the separation of plasmid DNA using short monolithic columns, Convective Interaction Media, will be presented. It will be demonstrated that plasmid DNA can be purified from bacterial cells using alkaline lysis followed by chromatography on a very short weak anion-exchange chromatographic columns-disks-with good purity and quality within a short time. Furthermore, the separation of plasmid DNA from cell RNA can be carried out without the need of adding RNAse. Fast and efficient method for in-process control of the purified plasmid will be described as well.
Collapse
Affiliation(s)
- Karmen Branovic
- Institute of Immunology Inc., Rockefeller Street 2, 10000 Zagreb, Croatia.
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Milavec Zmak P, Podgornik H, Jancar J, Podgornik A, Strancar A. Transfer of gradient chromatographic methods for protein separation to Convective Interaction Media monolithic columns. J Chromatogr A 2003; 1006:195-205. [PMID: 12938886 DOI: 10.1016/s0021-9673(03)00950-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Convective Interaction Media (CIM) columns are monolithic columns optimized for the separation of macromolecules. Some of them operate in the axial mode while others operate in the radial mode depending on the column size. In this work we tested the approach suggested by Yamamoto [Biotechnol. Bioeng., 48 (1995) 444] for transfer of gradient methods between columns of different size. A simplified equation for transfer was derived together with a criterion for its application. Separation was evaluated for a standard protein mixture and peroxidase enzymes present in fermentation broth. Salt and pH gradients were applied. Similar resolutions were obtained for each sample on all columns which demonstrates that the proposed approach can be successfully used for method scale-up on this type of column.
Collapse
|
24
|
Branovic K, Forcic D, Ivancic J, Strancar A, Barut M, Kosutic-Gulija T, Zgorelec R, Mazuran R. Application of short monolithic columns for improved detection of viruses. J Virol Methods 2003; 110:163-71. [PMID: 12798244 DOI: 10.1016/s0166-0934(03)00125-3] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Monolithic chromatography media represent a novel generation of stationary phases introduced in the last 10-15 years providing a chromatography matrix with enhanced mass transfer and hydrodynamic properties. These features allow for an efficient and fast separation of especially large biomolecules like e.g., DNA and viruses. In this study, the enrichment of virus RNA on short monolithic columns prior to molecular detection of viruses is described. Measles and mumps viruses were chosen as model viruses. The results show that it is possible to bind viral RNA on monoliths and concentrate viral nucleic acids from a fairly dilute sample. Consequently, a potential application of short monolithic columns is the concentration of virus RNA to improve the sensitivity and selectivity of viral detection with the possibility of isolating viral RNA from cell-free biological fluids.
Collapse
Affiliation(s)
- Karmen Branovic
- Institute of Immunology, Rockefeller Street 2, 10000, Zagreb, Croatia.
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Branović K, Buchacher A, Barut M, Strancar A, Josic D. Application of semi-industrial monolithic columns for downstream processing of clotting factor IX. J Chromatogr B Analyt Technol Biomed Life Sci 2003; 790:175-82. [PMID: 12767330 DOI: 10.1016/s1570-0232(03)00095-3] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
It has been shown in a previous study that monolithic columns can be used for downstream processing of different concentrates of clotting factor IX [K. Branović et al., J. Chromatogr. A 903 (2000) 21]. This paper demonstrates that such supports are useful tools also at an early stage of the purification process of factor IX from human plasma. Starting with the eluate after solid-phase extraction with DEAE-Sephadex, the use of monolithic columns has allowed much better purification than that achieved with conventional anion-exchange supports. The period of time required for separation is also much reduced. In up-scaling experiments, separations are carried out with 8, 80 and 500 ml columns. A volume of 1830 ml of DEAE-Sephadex eluate, containing a total of 27.6 g of protein and 48500 IU of factor IX is applied to the 500 ml monolithic column. This corresponds to a separation on a pilot scale. The results of this separation after up-scaling are comparable to those obtained with the 8 ml column on a laboratory scale.
Collapse
Affiliation(s)
- K Branović
- Institute of Immunology, Rockefellerova 2, 10000, Zagreb, Croatia
| | | | | | | | | |
Collapse
|
26
|
Miheli? I, Koloini T, Podgornik A. Temperature distribution effects during polymerization of methacrylate-based monoliths. J Appl Polym Sci 2003. [DOI: 10.1002/app.11913] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
27
|
Short Monolithic Columns Rigid Disks. ACTA ACUST UNITED AC 2003. [DOI: 10.1016/s0301-4770(03)80019-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
28
|
|
29
|
Pflegerl K, Podgornik A, Berger E, Jungbauer A. Screening for peptide affinity ligands on CIM monoliths. Biotechnol Bioeng 2002; 79:733-40. [PMID: 12209796 DOI: 10.1002/bit.10330] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Screening of peptide ligands for affinity chromatography usually involves incubation with the target protein in a batch system. In an additional step, peptides with fast binding kinetics have to be selected in respect to satisfactory performance under flow conditions on a support ensuring optimal three-dimensional presentation of the peptide. We have developed a rapid screening system based on peptide synthesis and screening on CIM((R)) disks. The disk size was minimized to fit into microplates usually applied for solid-phase extraction. In combination with a vacuum manifold, semi-automated peptide synthesis and screening for binding to a target protein under simulated chromatography conditions are possible. Various analytical methods can be applied for parallel and automated determination of the quantity, integrity, or activity of the target protein in the flow through or bound to the affinity support. This system also allows parallel screening for suitable chromatographic conditions like running buffer, washing, and elution conditions.
Collapse
Affiliation(s)
- K Pflegerl
- Institute of Applied Microbiology, University of Agricultural Sciences, Muthgasse 18, Vienna, Austria
| | | | | | | |
Collapse
|
30
|
Podgornik A, Tennikova TB. Chromatographic reactors based on biological activity. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2002; 76:165-210. [PMID: 12126268 DOI: 10.1007/3-540-45345-8_5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
Abstract
In the last decade there were many papers published on the study of enzyme catalyzed reactions performed in so-called chromatographic reactors. The attractive feature of such systems is that during the course of the reaction the compounds are already separated, which can drive the reaction beyond the thermodynamic equilibrium as well as remove putative inhibitors. In this chapter, an overview of such chromatographic bioreactor systems is given. Besides, some immobilization techniques to improve enzyme activity are discussed together with modern chromatographic supports with improved hydrodynamic characteristics to be used in this context.
Collapse
|
31
|
Strancar A, Podgornik A, Barut M, Necina R. Short monolithic columns as stationary phases for biochromatography. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2002; 76:49-85. [PMID: 12126271 DOI: 10.1007/3-540-45345-8_2] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
Monolithic supports represent a novel type of stationary phases for liquid and gas chromatography, for capillary electrochromatography, and as supports for bioconversion and solid phase synthesis. As opposed to individual particles packed into chromatographic columns, monolithic supports are cast as continuous homogeneous phases. They represent an approach that provides high rates of mass transfer at lower pressure drops as well as high efficiencies even at elevated flow rates. Therefore, much faster separations are possible and the productivity of chromatographic processes can be increased by at least one order of magnitude as compared to traditional chromatographic columns packed with porous particles. Besides the speed, the nature of the pores allows easy access even in the case of large molecules, which make monolithic supports a method of choice for the separation of nanoparticles like pDNA and viruses. Finally, for the optimal purification of larger biomolecules, the chromatographic column needs to be short. This enhances the speed of the separation process and reduces backpressure, unspecific binding, product degradation and minor changes in the structure of the biomolecule, without sacrificing resolution. Short Monolithic Columns (SMC) were engineered to combine both features and have the potential of becoming the method of choice for the purification of larger biomolecules and nanopartides on the semi-preparative scale.
Collapse
|
32
|
Gupalova TV, Lojkina OV, Pàlàgnuk VG, Totolian AA, Tennikov TB. Quantitative investigation of the affinity properties of different recombinant forms of protein G by means of high-performance monolithic chromatography. J Chromatogr A 2002; 949:185-93. [PMID: 11999734 DOI: 10.1016/s0021-9673(02)00032-8] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The recombinantly produced different forms of protein G, namely monofunctional immunoglobulin G (IgG) binding, monofunctional serum albumin (SA) binding and bifunctional IgG/SA binding proteins G, are compared with respect to their specific affinities to blood IgG and SA. The affinity mode of the recently developed high-performance monolithic disk chromatography has been used for fast quantitative investigations. Using single affinity disks as well as two discs stacked into one separation unit, one order of magnitude in adsorption capacities for IgG and SA were found both for monofunctional and bifunctional protein G forms used as specific affinity ligands. However, despite the adsorption difference observed, the measured dissociation constants of the affinity complexes seemed to be very close. The analytical procedure developed can be realized within a couple of minutes. Up-scaling of the developed technology was carried out using another type of monolithic materials, i.e. CIM affinity tubes.
Collapse
Affiliation(s)
- T V Gupalova
- Institute of Experimental Medicine, Russian Academy of Medical Sciences, St. Petersburg
| | | | | | | | | |
Collapse
|
33
|
Pflegerl K, Podgornik A, Berger E, Jungbauer A. Direct synthesis of peptides on convective interaction media monolithic columns for affinity chromatography. JOURNAL OF COMBINATORIAL CHEMISTRY 2002; 4:33-7. [PMID: 11790136 DOI: 10.1021/cc0100060] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Solid-phase peptide synthesis was performed on glycidyle methacrylate-co-ethylene dimethacrylate monoliths using Fmoc chemistry. The native epoxy groups were amino-functionalized by reaction with ethylenediamine or ammonia ions. A peptide directed against human blood coagulation factor VIII was synthesized as a model peptide. Amino acid analysis revealed the correct amino acid ratio as present in the sequence. The ligand density of 5 micromol/mL was equal to that achieved with conventional peptide immobilization via epoxy groups. These supports were directly used as peptide affinity chromatography matrixes. The functionality of the CIM monolithic supports was proven by affinity chromatography of factor VIII. The ammonia-functionalized support performed with low hydrophobicity and did not show unspecific adsorption of proteins.
Collapse
Affiliation(s)
- Karin Pflegerl
- Institute of Applied Microbiology, University of Agricultural Sciences, Muthgasse 18, A-1190 Vienna, Austria
| | | | | | | |
Collapse
|
34
|
Josić D, Buchacher A. Application of monoliths as supports for affinity chromatography and fast enzymatic conversion. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS 2001; 49:153-74. [PMID: 11694278 DOI: 10.1016/s0165-022x(01)00195-6] [Citation(s) in RCA: 98] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Monoliths are useful chromatographic supports, as their structure allows improved mass transport. This results in fast separation. Once the ligand of interest has been immobilized, chromatographic separation can also be accomplished in affinity mode. Ligands with low molecular mass have been shown to be the easiest to immobilize. Nowadays, ligands with low molecular mass are often designed by combinatorial chemical techniques. In addition, many applications have been described where ligands with high molecular mass, such as Proteins A and G, antibodies, lectins and receptors are used. The immobilization of an enzyme on the monolithic support creates a flow-through reactor. Small proteins, such as carbonic anhydrase, can be directly immobilized on the support. However, in the case of large molecules, the active center of the enzyme is no longer accessible at all or only to a limited degree. An improvement can be achieved by introducing a spacer, which allows maximum enzymatic conversion. Fast conversion of substrates with high molecular mass has been investigated with immobilized trypsin. It was shown that in case of high-molecular-mass substrates, the conversion rate depends very much on the flow-rate. Most applications described have been performed on an analytical or semi-preparative scale. However, the technical problems of up-scaling are close to being definitely solved, enabling enzymatic conversion on a preparative scale in the future.
Collapse
Affiliation(s)
- D Josić
- Research and Development, Octapharma Pharmazeutika Produktions Ges.m.b.H., Oberlaaerstrasse 235, A-1100 Vienna, Austria.
| | | |
Collapse
|
35
|
Zou H, Luo Q, Zhou D. Affinity membrane chromatography for the analysis and purification of proteins. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS 2001; 49:199-240. [PMID: 11694281 DOI: 10.1016/s0165-022x(01)00200-7] [Citation(s) in RCA: 187] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Affinity chromatography is unique among separation methods as it is the only technique that permits the purification of proteins based on biological functions rather than individual physical or chemical properties. The high specificity of affinity chromatography is due to the strong interaction between the ligand and the proteins of interest. Membrane separation allows the processing of a large amount of sample in a relatively short time owing to its structure, which provides a system with rapid reaction kinetics. The integration of membrane and affinity chromatography provides a number of advantages over traditional affinity chromatography with porous-bead packed columns, especially with regard to time and recovery of activity. This review gives detailed descriptions of materials used as membrane substrates, preparation of basic membranes, coupling of affinity ligands to membrane supports, and categories of affinity membrane cartridges. It also summarizes the applications of cellulose/glycidyl methacrylate composite membranes for proteins separation developed in our laboratory.
Collapse
Affiliation(s)
- H Zou
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116011, China.
| | | | | |
Collapse
|
36
|
Zorec M, Cepeljnik T, Nekrep FV, Logar RM. Multiple endoxylanases of Butyrivibrio sp. Folia Microbiol (Praha) 2001; 46:94-6. [PMID: 11501489 DOI: 10.1007/bf02825897] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Butyrivibrio sp. Mz 5 with a high xylanolytic activity was isolated. Four major xylanases were detected in the cell-associated fraction using the zymogram technique. The xylanolytic activity was inducible with the oat spelts xylan; two endoxylanases (51 and 145 kDa) were formed constitutively. The bulk of the xylanolytic activity was cell-bound and growth-phase dependent; the maximum activity in the cell-associated fraction was achieved after 16 h of incubation. The highest xylanolytic activity was determined in a medium with 0.5% oat spelts xylan. Under optimum conditions (the highest xylanolytic activity produced), the two cell-bound xylanases (51 and 58 kDa) were isolated by anion exchange chromatography on CIM DEAE 8 tubes attached to a MPLC system, and gel filtration.
Collapse
Affiliation(s)
- M Zorec
- Zootechnical Department, Biotechnical Faculty, University of Ljubljana, 1230 Domzale, Slovenia
| | | | | | | |
Collapse
|
37
|
Mihelič I, Krajnc M, Koloini T, Podgornik A. Kinetic Model of a Methacrylate-Based Monolith Polymerization. Ind Eng Chem Res 2001. [DOI: 10.1021/ie010146m] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Igor Mihelič
- Faculty of Chemistry and Chemical Technology, University of Ljubljana, Aškerčeva 5, SI-1000 Ljubljana, Slovenia
| | - Matjaž Krajnc
- Faculty of Chemistry and Chemical Technology, University of Ljubljana, Aškerčeva 5, SI-1000 Ljubljana, Slovenia
| | - Tine Koloini
- Faculty of Chemistry and Chemical Technology, University of Ljubljana, Aškerčeva 5, SI-1000 Ljubljana, Slovenia
| | - Aleš Podgornik
- Bia Separations d.o.o., Teslova 30, SI-1000 Ljubljana, Slovenia
| |
Collapse
|
38
|
Josic D, Buchacher A, Jungbauer A. Monoliths as stationary phases for separation of proteins and polynucleotides and enzymatic conversion. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 752:191-205. [PMID: 11270861 DOI: 10.1016/s0378-4347(00)00499-0] [Citation(s) in RCA: 182] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Monoliths are considered as a novel generation of stationary phases. They were applied for capillary electrochromatography and liquid chromatography exploiting every action principle such as ion-exchange, affinity recognition, reversed-phase, and hydrophobic interaction. The fast separation was explained by convective transport of the solutes through the bed. The contribution of this mode of transport is similarly explained as done for the beds packed with particles with gigapores. For monolithic beds, the concept of an ultrashort bed was frequently used. This mode of operation allows very short separation time. In many cases a gradient elution is necessary to achieve separation. Examples of applications for protein and polynucleotide separation performed on monoliths are given. Enzymatic conversion was described showing the examples of several immobilzed enzymes.
Collapse
Affiliation(s)
- D Josic
- Octapharma Pharmazeutika Produktions Ges.m.b.H., Vienna, Austria
| | | | | |
Collapse
|
39
|
Josić D, Hoffer L, Buchacher A, Schwinn H, Frenzel W, Biesert L, Klöcking HP, Hellstern P, Rokicka-Milewska R, Klukowska A. Manufacturing of a prothrombin complex concentrate aiming at low thrombogenicity. Thromb Res 2000; 100:433-41. [PMID: 11150587 DOI: 10.1016/s0049-3848(00)00339-x] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The paper describes the production of a prothrombin complex concentrate (PCC) with high virus safety and a well-balanced content of vitamin K-dependent clotting factors and inhibitors. Solid-phase extraction is followed in a second step by optimized anion exchange chromatography using a radial column. A step for virus removal by nanofiltration is introduced in addition to the solvent/detergent step. By speeding up the chromatographic step, the period of time required for production is reduced considerably. The activities of the four vitamin K-dependent clotting factors II, VII, IX and X are in ratios of about 1:1:1:1. Protein C, Protein S, and Protein Z are also present in therapeutically effective concentrations. The product shows no thrombogenicity, in either in vivo nor in vitro models. Clinical investigations show that the PCC is a safe and efficient preparation for the substitutive treatment of FIX or FVII in patients suffering from the respective deficiencies. All bleeding episodes have been efficiently controlled with relatively low doses of the concentrate. The surgical procedures have been conducted without any problems in severely FIX and FVIII deficient patients.
Collapse
Affiliation(s)
- D Josić
- Octapharma Pharmazeutika Produktionsges.m.b.H., Oberlaaer Str. 235, A-1100, Vienna, Austria.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Branović K, Buchacher A, Barut M, Strancar A, Josić D. Application of monoliths for downstream processing of clotting factor IX. J Chromatogr A 2000; 903:21-32. [PMID: 11153943 DOI: 10.1016/s0021-9673(00)00899-2] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
In this paper, the application of monolithic columns for downstream processing of different clotting factor IX concentrates is shown. Determination of basic chromatographic conditions as well as investigations on the regeneration of disk- and tube-shaped monolithic columns using human serum albumin as a model protein, were performed. Separation of factor IX and vitronectin, a possible impurity in commercial factor IX concentrates was accomplished using disk-shaped monolithic columns. These same applications were also carried out with identical results on up-scaled tube-shaped monolithic columns. Since these media allow very fast separations, this method can be successfully applied not only to an in-process control of the purification of factor IX but also to other biopolymers from human plasma. Besides, the same application on the up-scaled tube-shaped monolithic column was successfully carried out.
Collapse
Affiliation(s)
- K Branović
- Institute of Immunology, Zagreb, Croatia
| | | | | | | | | |
Collapse
|
41
|
Podgornik A, Barut M, Strancar A, Josić D, Koloini T. Construction of large-volume monolithic columns. Anal Chem 2000; 72:5693-9. [PMID: 11101250 DOI: 10.1021/ac000680o] [Citation(s) in RCA: 143] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Monolithic supports have become the subject of extensive study in the past years. Despite their advantageous features and many successful chromatographic applications in the analytical scale, only a very few examples of larger volume monoliths were described. In the case of GMA-EDMA monoliths, this can be attributed to the fact that due to the exothermic polymerization a pronounced temperature increase inside the monolith significantly affects the structure. The temperature increase depends on the thickness of the monolith, and consequently, there is an upper limit that allows the preparation of a unit with a uniform structure. In the present work, we have analyzed a heat release during the polymerization and have derived a mathematical model for the prediction of the maximal thickness of the monolithic annulus having a uniform structure. On the basis of the calculations, two annuluses of different diameters were polymerized and merged into a single monolithic unit with a volume of 80 mL. In addition, a special housing was designed to provide a uniform flow distribution in the radial direction over the entire monolith bed. It was shown that such a monolithic column exhibits flow-independent separation efficiency and dynamic binding capacity up to flow rates higher than 100 mL/min. The separation and loading times are in the range of a few minutes. The pressure drop on the column is linearly dependent on the flow rate and does not exceed 2.5 MPa at a flow rate of 250 ml/min.
Collapse
|
42
|
|
43
|
Application of Convective Interaction Media disks with immobilised glucose oxidase for on-line glucose measurements. Anal Chim Acta 2000. [DOI: 10.1016/s0003-2670(99)00817-x] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
44
|
|
45
|
Pock K, Rizzi A, Josic D. Use of high-resolution techniques for the characterization of clotting factor VIII. J Chromatogr A 1999; 852:175-88. [PMID: 10480242 DOI: 10.1016/s0021-9673(99)00620-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Dealing with the structural characterization of clotting factor VIII (FVIII) requires the application of several high-resolution analytical techniques. Besides the analytical point of view, a detailed knowledge of FVIII structure, production and therapeutic application is necessary. This review gives an overview of most of the currently applied analytical methods and how they deal with the complex analytical problem, investigating FVIII in a sample matrix containing large amounts of accompanying plasma proteins.
Collapse
Affiliation(s)
- K Pock
- Octapharma Pharmazeutika Produktionsges.m.b.H., Vienna, Austria.
| | | | | |
Collapse
|
46
|
Josić D, Štrancar A. Application of Membranes and Compact, Porous Units for the Separation of Biopolymers. Ind Eng Chem Res 1998. [DOI: 10.1021/ie970600f] [Citation(s) in RCA: 79] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Djuro Josić
- Octapharma Produktionsges m.b.H., Oberlaaer Strasse 235, A-1100 Wien, Austria
| | | |
Collapse
|
47
|
Giovannini R, Freitag R, Tennikova TB. High-performance membrane chromatography of supercoiled plasmid DNA. Anal Chem 1998; 70:3348-54. [PMID: 9726161 DOI: 10.1021/ac980390w] [Citation(s) in RCA: 87] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Membrane adsorbers are well established in protein chromatography. The present paper investigated for the first time the behavior of polynucleotides on these stationary phases, taking a 7.2-kb predominantly supercoiled plasmid as example. Gradient and isocratic elution was studied. In contrast to protein high-performance membrane chromatography (HPMC), isocratic elution is possible in DNA chromatography. In the case of gradient elution, much higher salt concentrations can be used in the starting buffer. Under optimized conditions, both approaches led to a splitting of the single plasmid peak into three maximums, which corresponded to the three-albeit isolated-bands in the agarose gel. Presumably the three fractions were supercoiled, nicked, and open circular plasmid DNA. Linearization of the plasmid lowered the adsorption energy, and the linearized plasmid eluted earlier than the nonlinearized one. The HPMC experiments were compared to similar ones performed using a conventional packed-bed anion-exchange column (BioScale Q2, 7 x 52 mm, 10-micron porous particles) and a novel monolithic-type anion-exchange column (UNO Q1, 7 x 35 mm). The results and characteristic differences observed in these experiments were interpreted in the light of the newly developed theory of HPMC.
Collapse
Affiliation(s)
- R Giovannini
- Laboratoire de Biotechnologie Cellulaire, Ecole Polytechnique Federale de Lausanne, Switzerland
| | | | | |
Collapse
|
48
|
Josić D, Schwinn H, Strancar A, Podgornik A, Barut M, Lim YP, Vodopivec M. Use of compact, porous units with immobilized ligands with high molecular masses in affinity chromatography and enzymatic conversion of substrates with high and low molecular masses. J Chromatogr A 1998; 803:61-71. [PMID: 9604327 DOI: 10.1016/s0021-9673(97)01282-x] [Citation(s) in RCA: 69] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Different ligands with high molecular masses are immobilized on compact, porous separation units and used for affinity chromatography. In subsequent experiments different enzymes are immobilized and used for converting substrates with low and high molecular masses. Disk or tube with immobilized concanavalin A (ConA) are used as model systems for lectin affinity chromatography. The enzyme glucose oxidase is used as a standard protein to test the ConA units. Subsequently glycoproteins from plasma membranes of rat liver are separated, using units with immobilized ConA. The enzyme dipeptidyl peptidase i.v., which is used as a model protein in the experiments, is enriched about 40-fold in a single step, with a yield of over 90%. The results are only slightly better than those obtained with ConA when it is immobilized on bulk supports. The important improvement lies in the reduction of separation time to only 1 h. Experiments concerning the isolation of monoclonal antibodies against clotting factor VIII (FVIII) are carried out on disks, combining anion-exchange chromatography and protein A affinity chromatography as a model for multidimensional chromatography. Both IgG (bound to the protein A disk) and accompanying proteins (bound to the anion-exchange disk) from mouse ascites fluid are retarded and eluted separately. With the immobilized enzymes invertase and glucose oxidase (GOX) the corresponding substrates with low molecular masses, saccharose and glucose, are converted. It is shown that the amount of immobilized enzyme and the concentration of the substrate are responsible for the extent of the conversion, whereas the flow-rates used in the experiments have no effect at all. The influence of immobilization chemistry was investigated with GOX. Indirect immobilization with ConA as spacer proved to be the best alternative. With trypsin, immobilized on a disk, substrates with high molecular masses are digested in flow-through. For optimal digestion the proteins have to be denatured in the buffer for sodium dodecyl sulfate-polyacrlyamide gel electrophoresis prior to application. In contrast to the conversion of substrates with low molecular masses, flow-rates play an important part in conversion of substrates with high molecular masses. With lower flow-rates a higher degree of digestion is achieved.
Collapse
Affiliation(s)
- D Josić
- Octapharma Pharmazeutika Produktionsges, mbH, Wien, Austria
| | | | | | | | | | | | | |
Collapse
|