Poeaim N, Hiran-Us S, Tantilertanant Y. Effect of irrigation protocols for post space preparation on the bond of the resin luting agent and post to a hydraulic calcium silicate filled root: An in vitro study. J Prosthet Dent 2025:S0022-3913(25)00064-2. [PMID: 39922747 DOI: 10.1016/j.prosdent.2025.01.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2024] [Revised: 01/22/2025] [Accepted: 01/24/2025] [Indexed: 02/10/2025]
Abstract
STATEMENT OF PROBLEM The hydraulic calcium silicate-based sealers (HCSSs) used in endodontic treatments have been reported to interfere with the bond of the post to root canal dentin. Post space irrigation plays a significant role in optimizing the bond, but which protocol is effective for cleaning HCSS-smeared intraradicular dentin is unclear. PURPOSE The purpose of this in vitro study was to evaluate the effect of passive ultrasonic irrigation (PUI) as an adjunct to different irrigation protocols, including with ethylenediaminetetraacetic acid (EDTA), chlorhexidine (CHX), and sodium hypochlorite (NaOCl), and root regions on the push-out bond strength of a self-etch primer-assisted resin luting agent adhered a post to root canal obturated with hydraulic calcium silicate sealer. MATERIAL AND METHODS The palatal root of 60 human maxillary premolars were shaped and obturated with gutta-percha and HCSS (iRoot SP). The post space was prepared using a peeso reamer and double taper drill, and the specimens were divided into 6 groups (n=10) according to the following irrigation protocols: distilled water with conventional syringe, distilled water with PUI, 17% EDTA with PUI, 2% CHX with PUI, 17% EDTA + 2.5% NaOCl with PUI, and 17% EDTA + 2% CHX with PUI. Fiber-reinforced posts (DT Light-Post) were cemented with dual-polymerizing resin luting agent with self-etching primer (Panavia V5). Specimens underwent 6000 thermocycles, were sectioned into 3 slices, and were tested for push-out bond strength and failure mode. The 2-way mixed ANOVA, Kruskal-Wallis H, Dunn post hoc, and chi-squared tests were used for statistical analysis (α=.05). RESULTS The PUI/EDTA/NaOCl group exhibited significantly higher push-out bond strength than irrigation with distilled water, whether incorporated with PUI or not (P=.001 and P=.007, respectively). The root region showed no statistical effects on bond strength (P>.05). The irrigation protocol was significantly associated with failure mode (P=.049). CONCLUSIONS PUI with EDTA/NaOCl followed by distilled water improved the bond strength of self-etch primer-assisted resin luting agent and fiber-reinforced post to an HCSS-obturated tooth. Alternative irrigation protocols did not significantly enhance bond strength.
Collapse
Affiliation(s)
- Nuttanun Poeaim
- Graduate student, Graduate operative, Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Sirawut Hiran-Us
- Assistant Professor, Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Yanee Tantilertanant
- Assistant Professor, Oral biology, Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
| |
Collapse
|
2
|
Rauber BF, De Carli JP, Dallepiane FG, Dogenski LC, Goedel F, Cecchin D, Palhano HS, Corazza PH, Collares KF, Souza MA, Farina AP. Aspects of glass and hybridization protocols for bonding of fiber posts to root dentine. Eur J Oral Sci 2024; 132:e13002. [PMID: 38938069 DOI: 10.1111/eos.13002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 06/03/2024] [Accepted: 06/06/2024] [Indexed: 06/29/2024]
Abstract
This study evaluated bond strength of glass fiber posts to root dentin using push-out (PO) and diametral compression (DC), testing glycolic acid as a conditioner and varying dentin moisture. An additional aim was to test whether DC can be an alternative test to PO for bond strength assessment. Eighty bovine teeth were divided into eight groups (n = 10) defined by the use of either 37% glycolic acid or 37% phosphoric acid (PA) on moist or wet dentin before bonding with either Adapter SingleBond/RelyX ARC or One Step Plus/Duo-Link Bisco. Each tooth provided discs with an internal diameter of 2 mm, external diameter of 5 mm, and height of 2 mm, which underwent PO and DC. Finite element analysis (FEA) was carried out on 3D models. When analyzing PO results through linear regression, the highest values of bond strength were observed using glycolic acid on wet dentin in the cervical and middle thirds of the teeth. Analyzing DC results, the only statistical influence on values was the dental thirds. The scatterplot of the DC results and the PO bond strength values indicated no relationship between the results of the two tests (r = 0.03; p = 0.64). PO test detected more sensitive changes in bond strength values than DC.
Collapse
Affiliation(s)
| | | | | | | | - Fábio Goedel
- School of Engineering, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Doglas Cecchin
- School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | | | | | | | | | - Ana Paula Farina
- School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| |
Collapse
|
3
|
Maluly-Proni AT, Queiroz ME, Gomes MH, Suzuki TYU, Reis BDO, dos Santos PH. Relined fiberglass posts: influence of resin opacity on the bond strength to intraradicular dentin. Braz Dent J 2024; 35:5746. [PMID: 39045986 PMCID: PMC11262759 DOI: 10.1590/0103-6440202405746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Accepted: 02/23/2024] [Indexed: 07/25/2024] Open
Abstract
This study aimed to evaluate the bond strength between relined fiberglass posts with different composite resin opacities in different thirds of the intraradicular dentin. Thirty single-rooted premolars were endodontically treated and divided into three groups (n=10): fiberglass posts relined with translucent composite resin, fiberglass posts relined with opaque composite resin, and fiberglass posts without relining. After cementation of the posts, the specimens were cut perpendicular to the long axis of the tooth in slices of approximately 1.3 mm of each third to be analyzed (cervical, middle, and apical) and then subjected to the push-out test. The bond strength (MPa) data were subjected to Shapiro-Wilk normality tests and two-way repeated measures analysis of variance, considering the experimental groups and different regions as study factors. Tukey's post-hoc test (p<.05) was applied for comparisons between the groups. In the cervical third, higher values of bond strength were found for the group relined with translucent resin, with a statistically significant difference for the other groups. In the other regions, both opaque and translucent resins showed similar results, but both showed higher values of bond strength compared to fiberglass posts without relining. The bond strength of fiberglass posts to different thirds of intraradicular dentin is influenced by composite resin relining as well as the opacity of the resin. The use of translucent composite resin is a more effective alternative for fiberglass posts relining.
Collapse
Affiliation(s)
- Ana Teresa Maluly-Proni
- Department of Preventive and Restorative Dentistry, Araçatuba School of Dentistry, São Paulo State University, UNESP, Araçatuba, São Paulo, Brazil
| | - Mariana Elias Queiroz
- Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University, UNESP, Araçatuba, São Paulo, Brazil
| | - Matheus Henrique Gomes
- Department of Preventive and Restorative Dentistry, Araçatuba School of Dentistry, São Paulo State University, UNESP, Araçatuba, São Paulo, Brazil
| | - Thaís Yumi Umeda Suzuki
- Department of Restorative Dentistry, Federal University of Minas Gerais, UFMG, Belo Horizonte, MG, Brazil
| | - Bruna de Oliveira Reis
- Department of Preventive and Restorative Dentistry, Araçatuba School of Dentistry, São Paulo State University, UNESP, Araçatuba, São Paulo, Brazil
| | - Paulo Henrique dos Santos
- Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University, UNESP, Araçatuba, São Paulo, Brazil
- Dental Research Institute, University of Toronto, Faculty of Dentistry - UofT, Toronto, ON, Canada
| |
Collapse
|
4
|
Souza MA, Zanella ML, Vanin GN, Dallepiane FG, Pizzi CYM, Ferreira ER, Fuhr MCS, Piccolo NM, Palhano HS, da Silva Koch J, Souza KR, da Costa UM, Dos Santos VV, Steier L, Bertol CD, Figueiredo JAPD. Antimicrobial action and cytotoxicity of hypochlorous acid obtained from an innovative electrolytic device - An in vitro study. Arch Oral Biol 2024; 163:105966. [PMID: 38657440 DOI: 10.1016/j.archoralbio.2024.105966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 04/01/2024] [Accepted: 04/06/2024] [Indexed: 04/26/2024]
Abstract
OBJECTIVE This study evaluated the antimicrobial effect and cytotoxicity of hypochlorous acid(HClO) obtained from an innovative electrolytic device. DESIGN The root canals of fifty extracted human teeth were inoculated with Enterococcus faecalis and divided into 5 groups (n = 10): DW (control); 2% chlorhexidine gel(CHX); 2.5% sodium hypochlorite(NaOCl); 250 ppm HClO and 500 ppm HClO. The counting of colony forming units evaluated the decontamination potential of each group. Cytotoxicity was evaluated after inoculation of tested protocols in fibroblastic cells for 3 min, calculating the cell viability. Specific statistical analysis was performed (α = 5%). RESULTS The highest bacterial reduction was observed in experimental groups, with no statistical differences from each other (p > 0.05). The highest number of viable cells was observed in control group, followed by 250 ppm HClO and 500 ppm HClO groups, with statistical differences from each other (p < 0.05). CONCLUSIONS It could be concluded that HClO presented high antimicrobial activity and low cytotoxicity at both tested concentrations.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | - Jordana da Silva Koch
- School of Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - Kellyn Rocca Souza
- School of Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | | | | | - Liviu Steier
- School of Dental Medicine, University of Pennsylvania, Philadelphia, PA, USA; Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, India
| | | | | |
Collapse
|
5
|
Lima RO, Barros APO, Alencar CDM, Pereira KDF, Galvani LD, Vaz LG, Campos EAD, Kuga MC. Influence of using different translucent composite resins for customizing fiber post on the bond strength of self-adhesive cement to root dentin. Dent Mater J 2024; 43:112-118. [PMID: 38072411 DOI: 10.4012/dmj.2023-184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
This study evaluated the influence of different translucent resins (Z350 and Opallis) for customizing fiber posts and light-curing the cementation system using different LED equipment (V, Valo or R, Radii-Cal) on the bond strength and adhesive failure pattern at 24 h and 6 months. Eighty roots were prepared and divided into 4 groups (n=20): ZV (Z350 resin and LED Valo), ZR (Z350 resin and LED Radii-Cal), OV (Opallis resin and LED Valo), OR (Opallis resin and LED Radii-Cal). After post space preparation, the fiber post was customized and cemented with self-adhesive cement and light-curing using V or R LED equipment. Bond strength values were submitted to 2-way ANOVA test. ZV and ZR showed higher bond strength values than the other groups at 6 months of evaluation (p<0.05). The Z350 resin has a favorable influence on the bond strength of self-adhesive cement to root dentin, regardless of the LED polymerization equipment used.
Collapse
Affiliation(s)
- Reinaldo Oliveira Lima
- Department of Operative Dentistry, Araraquara Dental School, São Paulo State University (UNESP)
| | | | - Cristiane De Melo Alencar
- Department of Restorative Dentistry, School of Dentistry, University Center of the State of Pará (CESUPA)
| | | | - Lucas David Galvani
- Department of Operative Dentistry, Araraquara Dental School, São Paulo State University (UNESP)
| | - Luís Geraldo Vaz
- Department of Dental Materials and Prosthetics Araraquara Dental School, São Paulo State University (UNESP)
| | - Edson Alves De Campos
- Department of Operative Dentistry, Araraquara Dental School, São Paulo State University (UNESP)
| | - Milton Carlos Kuga
- Department of Operative Dentistry, Araraquara Dental School, São Paulo State University (UNESP)
| |
Collapse
|
6
|
Nozari A, Rasoolzade B, Jowkar Z, Hamidi SA, Jowkar M. Evaluation of the Effects of Different Types of Resin Cement Systems on the Push-Out Bond Strength of the Fiber Post to Intracanal Dentin in Anterior Primary Teeth. Int J Dent 2023; 2023:8645083. [PMID: 38021345 PMCID: PMC10661842 DOI: 10.1155/2023/8645083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 09/15/2023] [Accepted: 10/20/2023] [Indexed: 12/01/2023] Open
Abstract
Background This study aimed to evaluate the effects of using three different resin cements on push-out bond strength (PBS) of fiber posts to root canal dentin of primary teeth. Methods Fifty primary canines were randomly divided into five experimental groups according to the type of the luting agent used for fiber post cementation after endodontic treatment and post space preparation as the following: Group 1: glass ionomer cement (GIC), Group 2: flowable resin composite, Group 3: etch and rinse (E&R) resin cement, Group 4: self-etch (SE) resin cement, Group 5: self-adhesive (SA) resin cement. The PBS values of the cemented fiber posts to root canals were measured. The data were statistically analyzed using a one-way analysis of variance, followed by Tukey's post hoc test. Results The highest mean PBS value was observed in Group 4 (SE resin cement), followed by Group 3 (E&R resin cement), and the lowest PBS value belonged to Group 1 (GIC), followed by Group 5 (p-values < 0.05). The mean PBS of Group 3 (E&R resin cement) was significantly higher than those of Groups 1 (GIC), 2 (flowable resin composite), and 5 (SA resin cement) (p-values < 0.05). However, no significant difference was found between the mean PBS of GIC and SA resin cement (p-value >0/05). Conclusion Using SE resin cement for fiber post cementation in primary anterior teeth showed the best results, followed by E&R resin cement. The lowest PBS was observed for GIC, followed by SA resin cement.
Collapse
Affiliation(s)
- Ali Nozari
- Department of Pediatric Dentistry, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Boshra Rasoolzade
- Department of Pediatric Dentistry, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Zahra Jowkar
- Oral and Dental Disease Research Center, Department of Operative Dentistry, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Seyed Ahmadreza Hamidi
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Jowkar
- Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
7
|
Hazar A, Akgül S, Hazar E. Effect of chlorhexidine and benzalkonium chloride on the long-term push-out bond strength of fiber posts. Niger J Clin Pract 2023; 26:1242-1248. [PMID: 37794535 DOI: 10.4103/njcp.njcp_434_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/06/2023]
Abstract
Background and Aim Fiber posts are widely used in endodontically treated teeth with extensive loss of coronal structure. The purpose of this study was to investigate immediate and the long-term effects of chlorhexidine (CHX) and benzalkonium chloride (BAC) application, on the push-out bond strength of fiber posts. Material and Methods Sixty mandibular premolars were decoronated, and root canal treatment was performed. After post space preparation, the specimens were divided into three groups according to the post space-surface pretreatment (n = 20); no surface treatment (control group-Group 1), 2% CHX application (Group 2), and 1% BAC application (Group 3). A self-curing adhesive cement and an etch and rinse adhesive were used for the cementation of posts. Three sections (one cervical, one middle, and one apical) of 1 mm thickness were prepared from each specimen. A push-out test was performed immediately on the half of the specimen sections (n = 10). The other half of the specimen sections were subjected to 20.000 thermal cycles before applying the push-out test (n = 10). The failure mode of each specimen was observed under a stereomicroscope at ×40 magnification. Results The data were analyzed by one-way analysis of variance (ANOVA), Tukey Honestly significant difference (HSD), and Tamhane tests (P = 0.05). The cervical thirds displayed the highest, and the apical thirds showed the lowest values in all groups (P < 0.05), except the control-aged group (P = 0.554). The aged control groups' values were found to be significantly lower than the aged CHX and BAC groups (P < 0.001). Aging significantly reduced the bond strength values of specimens in control groups (P < 0.001). However, aging did not significantly affect the push-out bond strength values of CHX and BAC groups (P > 0.050). The failure types were adhesive between the post and cement (type 1) in all groups, except control-aged group (type 2). Conclusion The application of 2% chlorhexidine or 1% BAC may be an essential step that can be taken to preserve the bond strength of fiber posts.
Collapse
Affiliation(s)
- A Hazar
- Faculty of Dentistry, Department of Restorative Dentistry, Zonguldak Bülent Ecevit University, Faculty of Dentistry, Ankara, Turkey
| | - S Akgül
- Department of Restorative Dentistry, Gazi University, Faculty of Dentistry, Ankara, Turkey
| | - E Hazar
- Department of Endodontics, Zonguldak Bülent Ecevit University, Zonguldak, Turkey
| |
Collapse
|
8
|
Khanum Hm K, Abdulmajeed Barakat A, Qamar Z, Reddy RN, Vempalli S, Ramadan AH, Niazi F, Noushad M. Glass fiber post resistance to dislodgement from radicular dentin after using contemporary and conventional methods of disinfection. Photodiagnosis Photodyn Ther 2022; 40:103026. [PMID: 35872354 DOI: 10.1016/j.pdpdt.2022.103026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 07/17/2022] [Accepted: 07/20/2022] [Indexed: 12/14/2022]
Abstract
AIM The present study aimed to assess the bond integrity of curcumin photosensitizer (CPS) Photodynamic therapy (PDT) on fiber post disinfection bonded to radicular dentin in comparison to the conventional fiber post sterilant used. MATERIALS AND METHODS Fifty human permanent single-rooted premolars were utilized with the crown part sectioned using up to the cementoenamel junction. Root canal preparation was performed followed by canal obturation with gutta-percha (GP) and resin-based sealer. The post space was prepared using peso reamers leaving 4 mm at the apical part of the post space. Fifty glass fiber posts (GFP) were divided into five groups based on the surface disinfectant (n = 10). group 1: Autoclave sterilization (AS) group 2: chlorhexidine digluconate (CHX dig), group 3: CPS solution, group 4: 35% phosphoric acid (PA) gel, and group 5: No disinfection. Cementation was performed using dual-cure self-etch resin cement. Each tooth was sectioned and placed on the universal testing machine. Failure mode was analyzed using a stereomicroscope at 40x magnification. Statistical analysis was performed using one-way analysis of variance (ANOVA) and Tukey multiple comparison tests. (p = 0.05). RESULTS Intragroup comparison analysis demonstrated that group 2 in which 2% CHX dig was used as a post-surface disinfectant revealed the highest bond integrity at all three levels. Group 5 where no disinfectant was used to decontaminate the post surface exhibited the lowest bond values. In all the investigated groups, PBS values showed a downward trend from coronal to the apical third of the post space. Group 1 in which AS was used to sterilize the fiber post and group 3 in which CPS was smeared to decontaminate the GFPs surface-displayed comparable outcomes of PBS to group 5 specimens at all three levels. (p > 0.05). CONCLUSION CHX dig and PA post-surface disinfection displayed a positive impact on bond strength with the radicular dentin. However, CPS and AS do not reveal any effect on the PBS when used for post-decontamination.
Collapse
Affiliation(s)
- Khuthija Khanum Hm
- Department of Restorative and Prosthetic Dentistry, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia.
| | - Ali Abdulmajeed Barakat
- Department of Restorative and Prosthetic Dentistry, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia.
| | - Zeeshan Qamar
- Department of OMFS and Diagnostic Sciences, Faculty of Dentistry, Riyadh Elm University, Riyadh, Saudi Arabia.
| | - R Naveen Reddy
- Department of Prosthodontics, Faculty of Dentistry, Jazan University, Jazan, Saudi Arabia.
| | - Swetha Vempalli
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Jazan University, Jazan, Saudi Arabia.
| | - Anas Hussam Ramadan
- Department of OMFS and Diagnostic Sciences, Faculty of Dentistry, Riyadh Elm University, Riyadh, Saudi Arabia.
| | - Fayez Niazi
- Department of Restorative and Prosthetic Dentistry, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia.
| | - Mohammed Noushad
- Department of Restorative and Prosthetic Dentistry, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia.
| |
Collapse
|
9
|
Maso PC, Souza MA, Borba M, Goedel F, Farina AP, Cecchin D, Maso DC, Dogenski LC, Corazza PH, Palhano HS, Rauber BF, De Carli JP. Influence of photodynamic therapy, different final irrigants, and ultrasonic activation on the bond strength of glass fiber posts to root dentin. Photodiagnosis Photodyn Ther 2022; 40:103180. [PMID: 36323366 DOI: 10.1016/j.pdpdt.2022.103180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/15/2022] [Accepted: 10/27/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE To evaluate the influence of photodynamic therapy (PDT), different final irrigants, and ultrasonic activation (US) on the bond strength of glass fiber posts (GFP) to root dentin. METHODS One hundred twenty bovine roots were divided into 12 groups according to PDT application, the type of final endodontic irrigant, and US. The samples were divided into 12 groups (n = 10): G1-DW(distilled water); G2-DW+US; G3-17% EDTA; G4-17% EDTA+US; G5-17% GA (glycolic acid); G6-17% GA+US; G7-PDT+DW; G8-PDT+DW+US; G9-PDT+17% EDTA; G10-PDT+17% EDTA+US; G11-PDT+17% GA; G12-PDT+17% GA+US. After cementing the glass fiber posts with resin cement, roots were sectioned into 2-mm-thick slices. One slice from the cervical third and another from the middle third were used for the push out test (PO), and the other two for the diametral compression test (DC). Thus, 10 samples were obtained per third for each mechanical test (n = 10). Kruskal-Wallis and Student-Newman-Keuls tests were used to analyze PO and DC data, and Pearson's correlation test was used to verify the relationship between the variables. Failure patterns were analyzed with chi-square test. RESULTS Significant differences were found in the PO test among the experimental groups (p < 0.001; power=1.00). PDT improved bond strength when using EDTA. PDT and US increased bond strength when using GA. Favorable failure patterns occurred more frequently in Group GA+US. There was no correlation between data obtained with PO and DC tests (r = 0.112; p = 0.729). CONCLUSION PDT provided the highest bond strength values of GFP to root dentin when associated with GA and US or when associated only with EDTA.
Collapse
Affiliation(s)
| | | | - Márcia Borba
- School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Fábio Goedel
- School of Engineering, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Ana Paula Farina
- School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Doglas Cecchin
- School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | | | | | | | | | | | | |
Collapse
|
10
|
Paixão FCDO, Rodrigues VP, George R, Souza SDFC, Paiva AEM, Pereira ADFV. Compressive strength of premolars restored with ceramic crowns and supported with a glass fiber post using different luting agents. Saudi Dent J 2022; 34:617-622. [PMID: 36267533 PMCID: PMC9577347 DOI: 10.1016/j.sdentj.2022.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Revised: 07/20/2022] [Accepted: 07/25/2022] [Indexed: 11/15/2022] Open
Abstract
Objective The retention of glass fiber post (GFP) is considered a key factor for the long-term success of restorations of endodontically treated teeth. This study aimed to compare the compressive strength of a ceramic crown supported by a GFP using different luting agents. Methods Forty single-rooted premolars were randomly divided into four groups (n = 10 each): control group (teeth without a GFP), Ketac Cem group (glass ionomer), RelyX ARC group (conventional dual-curing resin), and RelyX U200 group (self-adhesive dual-curing resin). After luting of the posts and placement of all-ceramic crowns made using feldspathic porcelain (Noritake EX-3), they were exposed to thermocycling for 1000 cycles and compressive strength tests. Statistical analysis included Kruskal–Wallis test with Dunn’s multi-comparison test. Results The Ketac Cem group and RelyX U200 group showed significantly greater fracture resistance to compressive loading than the control group. Conclusion This study indicates a possible role of the luting agent used with the GFP in influencing the compressive strength of the restored teeth. In this study, the self-adhesive dual-curing resin and glass ionomer both offered resistance to fractures.
Collapse
|
11
|
Radicular canal disinfection by photosensitizers activated by photodynamic therapy and Er, Cr: YSGG laser bonded to glass fibre post using different cement types. An Invitro study. Photodiagnosis Photodyn Ther 2022; 37:102730. [DOI: 10.1016/j.pdpdt.2022.102730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2021] [Revised: 01/13/2022] [Accepted: 01/18/2022] [Indexed: 11/17/2022]
|
12
|
Surface modification of glass fiber-reinforced composite posts to enhance their bond strength to resin-matrix cements: an integrative review. Clin Oral Investig 2021; 26:95-107. [PMID: 34713360 DOI: 10.1007/s00784-021-04221-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 10/05/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Endodontically treated teeth usually can reveal an extensive loss of dental structure and require the use of intraradicular posts to provide adequate support and retention. Retention of the post depends on the surface treatment of the endodontic post itself and on the root canal dentin as well as on the type of resin-matrix cement. PURPOSE The main aim of this study was to conduct an integrative review on the influence of different surface treatment methods of glass fiber-reinfored resin composite (GFRC) posts on their push-out bond strength to resin-matrix cements in endodontically treated teeth rehabiliation. METHOD A literature search was performed on PubMed (via National Library of Medicine) regarding articles published within the last 10 years, using the following combination of search terms: "intracanal post" OR "endodontic post" OR "root canal post" OR "intraradicular post" OR "glass fiber" AND "resin cement" AND "adhesion" OR "bond strength" OR "shear bond strength" OR "push out". RESULTS Results from the selected studies recorded the highest push-out bond strength around 22.5 MPa) on GFRC posts to resin-matrix cements when the surfaces were pre-treated by grit-blasting with silicate followed by silane conditioning. However, high values of push-out bond strength (21.5 MPa) were also noticed for GFRC posts after etching with hydrogen peroxide followed by silance conditioning. Thus, the highest values of bond strength of endodontic posts to the resin-matrix cements were recorded when a combined physico-chemical approach was assessed. Non-treated surfaces showed the lowest bond strength values between 5 to and 9 MPa. Surface analyses of GFRC posts showed an increased roughness after grit-blasting or etching that promoted a mechanical interlocking of the adhesive and resin-matrix cements. CONCLUSION The combined treatment of glass fiber-reinforced resin composite post surfaces by physical and chemical methods can promote the increase in roughness and chemical functionalization of the surfaces prior to cementation., That results in a high mechanical interlocking of the resin-matrix cements and a stable retention of the teeth root intracanal posts. CLINICAL RELEVANCE Combining chemical and physical modification methods of surfaces can provide the most promising adhesion-enhancing pathways of GFRC posts to resin-matrix cements, that can decrease the risk of clinical failures by fracture and detachment of endodontic posts.
Collapse
|
13
|
Zamanian AH, Hakimaneh SMR, Mojahedi SM, Taghavi Damghani F, Shayegh F, Shayegh SS. Efficiency of Erbium-Doped Yttrium Aluminum Garnet Laser in Debonding Cemented Glass Fiber Posts: an in vitro Study. JOURNAL OF DENTISTRY (SHIRAZ, IRAN) 2021; 22:1-7. [PMID: 33681416 PMCID: PMC7921767 DOI: 10.30476/dentjods.2020.83933.1062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Statement of the Problem: The efficacy of erbium-doped yttrium aluminum garnet (Er; YAG) laser on the debonding properties of certain post materials has remained largely unexplored. Purpose: This study aimed to investigate the effect of Er; YAG laser irradiation on debonding of cemented glass fiber posts in root canal treated teeth. Materials and Method: In this in vitro study, forty root canal treated mandibular premolar teeth were used in this study. Glass fiber posts were bonded using Panavia F 2.0 cement in the root canal space, and samples were divided into two groups. In the test group, samples were exposed to laser radiation of 7W, 350mJ, frequency of 20Hz and discontinued washing spray. In the control group, samples were left untouched. In each group, samples were sectioned into 1.5mm thick slices from the coronal, middle, and apical thirds of the root (N=120). Tensile bond strengths were evaluated using the push-out test and the failure patterns were evaluated using scanning electron microscopy (SEM). To compare the laser and non-laser groups at each location, independent sample t test was applied, and to compare bond strength between the locations in each group, one-way ANOVA and Tukey’s HSD post hoc was applied. Results: A significant difference in tensile strength was observed between the laser-irradiated group and control group; tensile bond strength was much higher in the control group (p<0.001). The highest frequency of fractures was observed at the cement-dentin interface. Given the used parameters, complete debonding was not achieved in the laser-irradiated group. Conclusion: Laser radiation reduced the bond strength of glass fiber posts to resin cement without complete debonding.
Collapse
Affiliation(s)
- Amir Hossein Zamanian
- Postgraduate Student, Dept. of Prosthodontics, Faculty of Dentistry, Shahed University, Tehran, Iran
| | | | - Seyed Masoud Mojahedi
- Laser Application in Medical Sciences Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Farnaz Taghavi Damghani
- Postgraduate Student, Dept. of Prosthodontics, Faculty of Dentistry, Shahed University, Tehran, Iran
| | | | | |
Collapse
|
14
|
Singh N, Garg A, Mittal R. Comparative evaluation of pull-out bond strength of fiber post using different luting cements in endodontically treated teeth: An in-vitro study. ENDODONTOLOGY 2021. [DOI: 10.4103/endo.endo_7_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
15
|
Irie M, Maruo Y, Nishigawa G, Yoshihara K, Matsumoto T. Flexural Strength of Resin Core Build-Up Materials: Correlation to Root Dentin Shear Bond Strength and Pull-Out Force. Polymers (Basel) 2020; 12:polym12122947. [PMID: 33317215 PMCID: PMC7763007 DOI: 10.3390/polym12122947] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 12/02/2020] [Accepted: 12/08/2020] [Indexed: 11/16/2022] Open
Abstract
The aims of this study were to investigate the effects of root dentin shear bond strength and pull-out force of resin core build-up materials on flexural strength immediately after setting, after one-day water storage, and after 20,000 thermocycles. Eight core build-up and three luting materials were investigated, using 10 specimens (n = 10) per subgroup. At three time periods-immediately after setting, after one-day water storage, and after 20,000 thermocycles, shear bond strengths to root dentin and pull-out forces were measured. Flexural strengths were measured using a 3-point bending test. For all core build-up and luting materials, the mean data of flexural strength, shear bond strength and pull-out force were the lowest immediately after setting. After one-day storage, almost all the materials yielded their highest results. A weak, but statistically significant, correlation was found between flexural strength and shear bond strength (r = 0.508, p = 0.0026, n = 33). As the pull-out force increased, the flexural strength of core build-up materials also increased (r = 0.398, p = 0.0218, n = 33). Multiple linear regression analyses were conducted using these three independent factors of flexural strength, pull-out force and root dentin shear bond strength, which showed this relationship: Flexural strength = 3.264 × Shear bond strength + 1.533 × Pull out force + 10.870, p = 0.002). For all the 11 core build-up and luting materials investigated immediately after setting, after one-day storage and after 20,000 thermocycles, their shear bond strengths to root dentin and pull-out forces were correlated to the flexural strength in core build-up materials. It was concluded that the flexural strength results of the core build-up material be used in research and quality control for the predictor of the shear bond strength to the root dentin and the retentive force of the post.
Collapse
Affiliation(s)
- Masao Irie
- Department of Biomaterials, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1, Shikata-cho, Kita-ku, Okayama 700-8525, Japan;
- Correspondence: ; Tel.: +81-86-235-6668
| | - Yukinori Maruo
- Department of Occlusion and Removable Prosthodontics, Okayama University, 2-5-1, Shikata-cho, Kita-ku, Okayama 700-8558, Japan; (Y.M.); (G.N.)
| | - Goro Nishigawa
- Department of Occlusion and Removable Prosthodontics, Okayama University, 2-5-1, Shikata-cho, Kita-ku, Okayama 700-8558, Japan; (Y.M.); (G.N.)
| | - Kumiko Yoshihara
- National Institute of Advanced Industrial Science and Technology (AIST), Health and Medical Research Institute2217-14 Hayashi-cho, Takamatsu, Kagawa 761-0395, Japan;
| | - Takuya Matsumoto
- Department of Biomaterials, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1, Shikata-cho, Kita-ku, Okayama 700-8525, Japan;
| |
Collapse
|
16
|
Pereira R, Lins RBE, Rodrigues VC, Lima DANL, Martins LRM, Aguiar FHB. Glass fiber posts. BRAZILIAN JOURNAL OF ORAL SCIENCES 2020. [DOI: 10.20396/bjos.v19i0.8657508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
Aim: Glass fiber posts are indicated in the rehabilitation of extensively damaged teeth; their cementation represents a critical step in restorative dentistry. The aim of this study was to quantify and compare the push-out bond strength of glass fiber posts cemented by conventional technique, two-step technique with luting agent and two-step technique associating bulk-fill composite and luting agent. Methods: Eighty maxillary bovine incisors were endodontically treated and divided into eight groups (n = 10) according to the luting agent (Rely X ARC and Duo-link) and cementation technique (conventional technique; two-step technique with luting agent; and two-step technique associating bulk-fill composite – Filtek Bulk-fill flow or Surefil SDR flow – and luting agent). Samples were submitted to pushout bond strength test, and the fracture pattern was evaluated through scanning electron microscope. Data were submitted to two-way ANOVA and Tukey’s test (α = 0.05). Results: When Rely X ARC was used, the conventional cementation technique obtained higher bond strength values than the twostep technique associated with Filtek Bulk-fill flow. When Duolink was used, the two-step technique associated with Filtek Bulk-fill flow presented higher bond strength values than the conventional technique. The most prevalent fracture patterns were adhesive between luting agent and dentin, and adhesive between bulk-fill composite and dentin. Conclusion: Two-step cementation technique associated with bulk-fill composite may be promising depending on the luting agent used.
Collapse
|
17
|
Vicentin M, Portella FF, Reston EG, Braga C, Bianchi AL, Arossi GA. Evaluation of Tensile Bond Strength of Metallic Prefabricated Posts Cemented with Different Luting Agents. PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLÍNICA INTEGRADA 2020. [DOI: 10.1590/pboci.2020.089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
18
|
Belizário LG, Kuga MC, Hungaro Duarte MA, Só MVR, Keine KC, Pereira JR. Effect of fiber post space irrigation with different peracetic acid formulations on the bond strength and penetration into the dentinal tubules of self-etching resin cement. J Prosthet Dent 2019; 122:46.e1-46.e7. [PMID: 31182239 DOI: 10.1016/j.prosdent.2019.03.020] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 03/28/2019] [Accepted: 03/28/2019] [Indexed: 11/15/2022]
Abstract
STATEMENT OF PROBLEM The post space must be irrigated with solutions that do not interfere with the bond strength and enhance penetration into the dentinal tubules of self-etching resin cement. Which solution is best is unclear. Peracetic acid with different formulations appears to be a good option. PURPOSE The purpose of this in vitro study was to evaluate the effect of irrigating the fiber post space by using 1% peracetic acid (PA) at low (LH) or high (HH) hydrogen peroxide concentration on the bond strength and penetration into the dentinal tubules of RelyX U200 self-etching resin cement. MATERIAL AND METHODS After intraroot preparation for fiber posts in 60 endodontically treated teeth, the specimens were divided into 4 groups (n=15) according to the irrigation protocol: CG (control), distilled water; NA (NaOCl), 2.5% sodium hypochlorite; LHPA, PA with a low concentration of hydrogen peroxide; and HHPA, PA with a high concentration of hydrogen peroxide. The fiber posts were then cemented with self-etching resin cement labeled with rhodamine. Cross sections of the thirds were obtained by confocal scanning microscopy and submitted to the push-out and cement penetration tests. The data obtained in the push-out tests were evaluated by using ANOVA and the Tukey post hoc test, and those data obtained in the confocal screening were evaluated by using the Kruskal-Wallis and Dunn (Bonferroni correction) tests (α=.05). RESULTS Bond strength values in the cervical third of the CG were higher than those in NA (P=.035) but similar to those of the other groups (P=.05). In the other thirds, CG and LHPA values were similar to one another (P=.05) but higher than those of NA and HHPA (P<.001). The penetration rate assessed by confocal scanning microscopy revealed similar results in the cervical third for all groups (P=.075), except for NA which provided the lowest penetration. In the remaining thirds, CG and LHPA provided the highest penetration rate (P=.015). CONCLUSIONS The LHPA group had no negative effects on the bond strength and penetration into the dentinal tubules of the self-etching resin cement.
Collapse
Affiliation(s)
- Lauriê Garcia Belizário
- Doctoral student, Restorative Dentistry Department, Araraquara Dental School, São Paulo State University (UNESP), Araraquara, Brazil
| | - Milton Carlos Kuga
- Associate Professor, Restorative Dentistry Department, Araraquara Dental School, São Paulo State University (UNESP), Araraquara, Brazil
| | - Marco Antônio Hungaro Duarte
- Associate Professor, Department of Dentistry, Endodontic and Dental Materials, Bauru Dental School, São Paulo University (USP), Bauru, Brazil
| | - Marcus Vinicius Reis Só
- Associate Professor, Restorative Dentistry Department, Dental School, Rio Grande do Sul Federal University (UFRGS), Rio Grande do Sul, Brazil
| | - Kátia Cristina Keine
- Doctoral student, Restorative Dentistry Department, Araraquara Dental School, São Paulo State University (UNESP), Araraquara, Brazil
| | - Jefferson Ricardo Pereira
- Associate Professor, Postgraduate Program in Health Sciences, University of Southern Santa Catarina (UNISUL), Santa Catarina, Brazil.
| |
Collapse
|
19
|
Pang NS, Jung BY, Roh BD, Shin Y. Comparison of Self-Etching Ceramic Primer and Conventional Silanization to Bond Strength in Cementation of Fiber Reinforced Composite Post. MATERIALS 2019; 12:ma12101585. [PMID: 31096562 PMCID: PMC6567077 DOI: 10.3390/ma12101585] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 05/14/2019] [Accepted: 05/14/2019] [Indexed: 11/23/2022]
Abstract
Various mechanical and chemical surface treatments have been proposed to improve the retention of fiber-reinforced composite post (FRCP), but the results are still controversial. The bond strength and durability of a self-etching ceramic primer, which was recently released as an alternative to etching and silane, are not yet known. This study aimed to compare and evaluate the push-out bond strength of different surface treatments of FRCPs after an artificial aging procedure. Four groups (n = 10) were established to evaluated FRCP surface treatments (dentin adhesive bonding; silane and adhesive bonding; hydrofluoric acid, silane and adhesive bonding; and a self-etching ceramic primer). They were bonded with dual-curing rein cement (Multilink N) and stored in distilled water at 37 °C for 30 days, then thermal cycled for 7500 cycles. After being sectioned into 1 mm thickness, each coronal and apical part was evaluated for its the push-out bond strength by a universal testing machine. Each debonded specimen was observed by an optical microscope and divided according to the failure modes. The results showed that silane treatment significantly improved push-out bond strength, but the self-etching ceramic primer did not do so. Additional hydrofluoric acid treatment or the adhesive bonding agent alone did not significantly improve the retention of FRCPs. Cohesive failure of the luting material was found most frequently in all groups.
Collapse
Affiliation(s)
- Nan-Sim Pang
- Department of Advanced General Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Korea.
| | - Bock-Young Jung
- Department of Advanced General Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Korea.
| | - Byoung-Duck Roh
- Department of Conservative Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Korea.
| | - Yooseok Shin
- Department of Conservative Dentistry, Oral Science Research Center and Microscope center, College of Dentistry, Yonsei University, Seoul 03722, Korea.
| |
Collapse
|
20
|
Suzuki TYU, Pereira MA, Gomes-Filho JE, Wang L, Assunção WG, Santos PHD. Do Irrigation Solutions Influence the Bond Interface Between Glass Fiber Posts and Dentin? Braz Dent J 2019; 30:106-116. [DOI: 10.1590/0103-6440201901963] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Accepted: 06/12/2018] [Indexed: 11/22/2022] Open
Abstract
Abstract The aim of this study was to evaluate the push-out bond strength and interface permeability of glass-fiber posts in different regions of post space (cervical, middle, and apical) submitted to different irrigation solutions. Ninety single-rooted human teeth were submitted to endodontic treatment and divided into five groups, according to irrigation solutions: distilled water, 5.25% NaOCl, 25% polyacrylic acid, 2% chlorhexidine, and 23 ppm Ag NP dispersion. Each group was divided in 3 subgroups (n=6) according to cementation: SBU: Adper Scotchbond Universal + RelyX ARC; U200: RelyX U200; MCE: MaxCem Elite. Bond strength and sealing ability were measured in different areas of post space. The data was subjected to ANOVA and Fisher’s test (a=0,05). The silver nanoparticle solution showed highest bond strength values and lowest interface permeability in all thirds analyzed for SBU group. In the U200 group, the highest bond strength values were found for sodium hypochlorite solution, with significant difference between this solution and polyacrylic acid. A decrease in bond strength values in cervical to apical direction was found for MCE group and the same behavior were found for others groups. Regarding interface permeability, use of silver nanoparticle solution resulted in lower values in cervical and apical thirds. There was a decrease in bond strength in cervical to apical direction. Different irrigation solutions and intraradicular depth influenced the bond strength and interface permeability of adhesive material to dentin substrate. Silver nanoparticle solution can effectively be used as an irrigation agent in post space prior to fiber post cementation process.
Collapse
|
21
|
Webber MBF, Bernardon P, França FM, Amaral FL, Basting RT, Turssi CP. Oval Versus Circular-Shaped Root Canals: Bond Strength Reached with Varying Post Techniques. Braz Dent J 2018; 29:335-341. [DOI: 10.1590/0103-6440201801937] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Accepted: 04/13/2018] [Indexed: 11/22/2022] Open
Abstract
Abstract The aim of this study was to compare the bond strength (BS) of glass fiber posts (GFP) luted to oval and circular-shaped root canals rehabilitated using varying post techniques, at different intraradicular levels. Ninety 16-mm-long roots of human mandibular premolars, classified either as having oval or circular-shaped canals, were endodontically treated and prepared for restoration using one of three different post techniques (n=15): 1) single GFP; 2) resin-relined GFP; 3) main GFP associated with accessory posts. GFPs were luted with a dual polymerizing resin cement (RelyX ARC) after the canal had been treated with a 3-step etch-and-rinse adhesive system (Adper Scothbond Multipurpose). The samples were sectioned into three 1-mm-thick sections, which were differentiated by the root level (cervical, middle and apical) and tested for push-out BS. Assessment of failure mode was made under a stereomicroscope. Data were analyzed using repeated measures three-way ANOVA and Tukey’s test. The root canal cross-section had a significant influence on BS (p<0.001), with the lowest values being observed in oval-shaped canals. The post technique also significantly affected the BS (p=0.018), with the resin-relined GFPs providing the highest BS values in both oval and circular-shaped canals. Irrespective of the cross-section of the root canal and post technique, there was no significant difference in BS in the cervical, middle and apical third of the root canal (p=0.084). In oval-shaped canals, the BS to intraradicular dentin at cervical, middle or apical level could be increased when the GFPs posts were relined.
Collapse
|
22
|
Belizário LG, Kuga MC, Castro-Núñez GM, Escalante-Otárola WG, Só MVR, Pereira JR. Effects of different peracetic acid formulations on post space radicular dentin. J Prosthet Dent 2018; 120:92-98. [PMID: 29310877 DOI: 10.1016/j.prosdent.2017.08.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Revised: 08/01/2017] [Accepted: 08/02/2017] [Indexed: 10/18/2022]
Abstract
STATEMENT OF PROBLEM The optimal irrigating solution with antimicrobial and dentin cleansing properties for post space preparation for fiber posts is unclear. Peracetic acid is one option but is available in various chemical formulations that require evaluation. PURPOSE The purpose of this in vitro study was to evaluate dentin surface cleanliness based on the presence of a smear layer and the number of open dentin tubules. It also investigates the chemical composition of residues after canal irrigation with a 1% peracetic acid solution (PA) at low or high concentration of hydrogen peroxide during the preparation of intracanal fiber posts. MATERIAL AND METHODS After filling the root canals of 40 mandibular incisors, a rotary instrument was used for intracanal preparation to place fiber posts. The teeth were divided into 4 groups (n=10) according to the post space irrigation protocol as follows: CG (control): distilled water; NA (NaOCl): 2.5% sodium hypochlorite; LH: PA with low concentration of hydrogen peroxide; and HH: PA with high concentrations of hydrogen peroxide. After irrigation, the teeth were sectioned, and the intracanal dentin surface was subjected to analysis using energy dispersive spectroscopy to evaluate chemical composition and to scanning electron microscopy (×500) to evaluate the presence of the smear layer. The number of open dentin tubules was measured by scanning electron microscopy analysis (×2000) using photo-editing software. ANOVA and the Tukey test (α=.05) were used to evaluate the data, except for the presence of a smear layer, for which the Kruskal-Wallis and Dunn tests were used (α=.05). RESULTS The highest concentrations of oxygen in the dentin residues were detected in LH and HH (P<.05); CG and NA showed similar oxygen concentrations (P>.05). NA had a higher concentration of chlorine (P<.05), whereas LH had a lower amount of smear layer and a larger number of open dentin tubules than the other groups (P<.05). These were equivalent to each other (P>.05), except for HH, which also had a larger number of open dentin tubules than CG and NA (P<.05). CONCLUSIONS PA 1% with a low concentration of hydrogen peroxide yielded a lower amount of smear layer and a larger number of open dentin tubules in the dentin of the post space when compared with PA 1% with a high concentration of hydrogen peroxide, despite maintaining a similar oxygen concentration in these dentin residues.
Collapse
Affiliation(s)
- Lauriê Garcia Belizário
- Doctoral student, Restorative Dentistry Department, Araraquara Dental School, São Paulo State University, São Paulo, Brazil
| | - Milton Carlos Kuga
- Associate Professor, Restorative Dentistry Department, Araraquara Dental School, São Paulo State University, São Paulo, Brazil
| | - Gabriela Mariana Castro-Núñez
- Doctoral student, Restorative Dentistry Department, Araraquara Dental School, São Paulo State University, São Paulo, Brazil
| | | | - Marcus Vinicius Reis Só
- Associate Professor, Restorative Dentistry Department, Dental School, Rio Grande do Sul Federal University, Rio Grande do Sul, Brazil
| | - Jefferson Ricardo Pereira
- Associate Professor, Postgraduate Program in Health Sciences, University of Southern Santa Catarina, Santa Catarina, Brazil.
| |
Collapse
|
23
|
Knight B, Love RM, George R. Evaluation of the influence of time and concentration of sodium hypochlorite on the bond strength of glass fibre post. AUST ENDOD J 2017; 44:267-272. [PMID: 29064132 DOI: 10.1111/aej.12239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/13/2017] [Indexed: 11/30/2022]
Abstract
This study evaluated the effect of time and concentrations of sodium hypochlorite on the bond strength of a glass fibre post cemented in a root canal with resin cement. A total of 45 single-rooted extracted human teeth were prepared with Protaper® universal files, randomly allocated into nine groups and then subjected to 1% or 4% NaOCl for a period of 1 min or 2 min. Fibre posts were then bonded into the root canal, sectioned and the bond strength tested using a push-out test. A longer irrigation time resulted in a significant reduction (P < 0.05) in bond strength, while a final additional irrigation with distilled water significantly reduced bond strength. The concentration of NaOCl did not significantly affect bond strength. Within the limitations of this study, it was observed that regardless of the concentration of NaOCl used, shorter irrigation times favoured better fibre post bonding.
Collapse
Affiliation(s)
- Beau Knight
- School of Dentistry and Oral Health, Griffith University, Gold Coast, Queensland, Australia
| | - Robert M Love
- School of Dentistry and Oral Health, Griffith University, Gold Coast, Queensland, Australia
| | - Roy George
- School of Dentistry and Oral Health, Griffith University, Gold Coast, Queensland, Australia
| |
Collapse
|
24
|
Wagner MH, da Rosa RA, de Figueiredo JAP, Duarte MAH, Pereira JR, Só MVR. Final irrigation protocols may affect intraradicular dentin ultrastructure. Clin Oral Investig 2017; 21:2173-2182. [PMID: 27888349 DOI: 10.1007/s00784-016-2006-x] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2015] [Accepted: 11/01/2016] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate the effect of different irrigation protocols on the root dentin structure using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). MATERIALS AND METHODS Thirty-nine lower bovine incisors were hemisected longitudinally and randomly divided into 13 groups (n = 3). After the root halves were reassembled, it was applied a specific irrigation protocol for each group, as following: G1, distilled water (control); G2, 0.9% saline; G3, saline + 17% EDTA; G4, saline + PUI; G5, saline + PUI + EDTA; G6 to G9 received the same protocol as above replacing 0.9% saline by 2.5% NaOCl; and G10 to G13 by 2% CHX. One-half of each sample was prepared and evaluated using SEM and the other one by TEM observations. RESULTS TEM descriptive analysis showed modifications in dentin organic ultrastructure, characterized by the thinning of dentin collagen fibrils, caused by NaOCl, enhanced by EDTA and/or PUI. SEM analysis showed that NaOCl with PUI caused significantly larger erosion of the peritubular dentin than in all the other groups (P < 0.05), followed by NaOCl + EDTA and NaOCl + EDTA + PUI. CONCLUSIONS NaOCl caused ultrastructural alterations in the dentin collagen, and enhanced by EDTA and/or PUI, promoted peritubular and intertubular erosion. CLINICAL RELEVANCE The effect of irrigating solutions on dentin ultrastructure was still unclear. The acknowledgment about the kind of solution, concentrations, application time, and sequence of use was important to achieve the right sanitization without jeopardizing the dentin ultrastructure quality.
Collapse
Affiliation(s)
- Márcia Helena Wagner
- Department of Conservative Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - Ricardo Abreu da Rosa
- Department of Conservative Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | | | | | | | - Marcus Vinicius Reis Só
- Department of Conservative Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| |
Collapse
|
25
|
Effect of Anatomical Customization of the Fiber Post on the Bond Strength of a Self-Adhesive Resin Cement. Int J Dent 2017; 2017:5010712. [PMID: 28785281 PMCID: PMC5530420 DOI: 10.1155/2017/5010712] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2017] [Accepted: 06/08/2017] [Indexed: 11/18/2022] Open
Abstract
AIM The aim of the study was to evaluate, by means of the push-out test, the effect of the anatomical customization of the fiber post on the bond strength of a self-adhesive resin cement. METHODS Twelve endodontically treated, human, upper central incisors were randomly divided into two groups (n = 6): control (glass fiber posts cemented with Relyx® U200) and customized (glass fiber posts anatomically customized with translucent composite resin cemented with Relyx U200). The roots were sectioned into three slices, cervical, middle, and apical, and photographed with a digital camera attached to a stereomicroscopic loupe. The images were analyzed by software, for evaluation of the cement line. The slices were subsequently submitted to the push-out test until the post had completely extruded, and the fracture mode was analyzed with a stereomicroscopic loupe. RESULTS The results showed significant differences between the groups in the different root thirds in relation to the area occupied by air bubbles (p < 0.05). Bond strength, when all the thirds are considered, was 8.77 ± 4.89 MPa for the control group and 16.96 ± 4.85 MPa for the customized group. CONCLUSION The customized group showed greater bond resistance than the control group and a more uniform cement layer.
Collapse
|
26
|
Park JS, Lee JS, Park JW, Chung WG, Choi EH, Lee Y. Comparison of push-out bond strength of fiber-reinforced composite resin posts according to cement thickness. J Prosthet Dent 2017; 118:372-378. [PMID: 28222875 DOI: 10.1016/j.prosdent.2016.11.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Revised: 11/03/2016] [Accepted: 11/03/2016] [Indexed: 11/30/2022]
Abstract
STATEMENT OF PROBLEM Post space size and cement thickness can differ because of variations in root canal morphology, such as an oval shape, and because the entire canal space cannot be included in the post space preparation. As a result, increased cement thickness around the post may affect the bond strength between the post and the dentin. PURPOSE The purpose of this in vitro study was to evaluate the push-out bond strength of fiber-reinforced composite resin posts to root dentin with cement layers of varying thickness. MATERIAL AND METHODS Thirty human premolars were endodontically treated and restored with fiber-reinforced composite resin posts. Post space was prepared using a drill with a 1.5-mm diameter and diameters of 1.25 mm (small [S] group), 1.375 mm (medium [M] group), and 1.5 mm (large [L] group) were cemented. The specimens were sectioned horizontally into 1-mm-thick slices, and the push-out bond strengths of the apical and coronal fragments were evaluated. Bond strength was compared using analysis of variance and 2-sample t tests (α=.05). RESULTS No significant differences were found in the debonding force and push-out bond strength among fiber-reinforced composite posts of different sizes (P>.05). The mean debonding force and standard deviation of the posts were 25.05 ±9.52 N for the S group, 28.17 ±11.38 N for the M group, and 33.78 ±12.47 N for the L group. The corresponding push-out bond strength values were 3.11 ±1.54 MPa, 3.39 ±1.4 MPa, and 4.15 ±1.75 MPa. The differences in debonding force between the apical (26.43 ±10.72 N) and coronal (31.57 ±12.03 N) areas were not significant (P>.05). However, the differences in push-out bond strength between the apical (4.27 ±1.73 MPa) and coronal areas (2.83 ±1.08 MPa) were significant (P<.05). CONCLUSIONS The widening of post spaces and, consequently, the increased cement thickness do not significantly affect the bond strength of fiber-reinforced composite resin posts to root dentin.
Collapse
Affiliation(s)
- Jun-Seong Park
- Resident, Department of Conservative Dentistry, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University, Wonju, Republic of Korea
| | - Jeong-Sub Lee
- Assistant Professor, Department of Orthodontics, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University, Wonju, Republic of Korea
| | - Jeong-Won Park
- Professor, Department of Conservative Dentistry, Gangnam Severance Hospital, College of Dentistry, Yonsei University, Seoul, Republic of Korea
| | - Won-Gyun Chung
- Professor, Department of Conservative Dentistry, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University, Wonju, Republic of Korea
| | - Eun-Hee Choi
- Research Professor, Institute of Lifestyle Medicine, Wonju College of Medicine, Yonsei University, Wonju, Republic of Korea
| | - Yoon Lee
- Associate Professor, Department of Conservative Dentistry, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University, Wonju, Republic of Korea.
| |
Collapse
|
27
|
Pasdar N, Seraj B, Fatemi M, Taravati S. Push-out bond strength of different intracanal posts in the anterior primary teeth according to root canal filling materials. Dent Res J (Isfahan) 2017; 14:336-343. [PMID: 29109749 PMCID: PMC5654229 DOI: 10.4103/1735-3327.215959] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Background: This study was carried out to evaluate the effect of root canal filling on the bond strength of three intracanal posts in the primary incisors. Materials and Methods: Sixty primary incisors were prepared and then divided into two groups (n = 30). The first group canals obturated with zinc oxide eugenol (ZOE) and Group 2 canals obturated with Metapex. Further, the two group categories were divided into three subgroups (n = 10): (1) short composite post (SCP), (2) glass fiber posts (GFPs) cemented with flowable composite, and (3) GFP with glass ionomer cement (GFP + GIC). The push-out test was performed with a universal testing machine. The results were statistically analyzed with two-way analysis of variance.(α = 0.05). Results: The mean bond strength of the first group obturated with ZOE was lower than that of the second group obturated with Metapex (P = 0.046). Moreover, from a statistical point of view, in all three subgroups, the correlation of mean push-out bond strength between SCP and GFP coated with flowable composite was not substantial at P = 0.97. However, the mean bond strength of SCP was in fact significantly greater than that of the GFP coated with GIC since P = 0.034. Conclusion: Using ZOE resulted in the significant reduction of the mean bond strength of the intracanal posts when utilized in the primary anterior teeth. Likewise, SCP and GFP coated with flowable composite showed higher push-out bond strengths for restoring primary anterior teeth.
Collapse
Affiliation(s)
- Nilgoon Pasdar
- Department of Pediatric Dentistry, Babol University of Medical Sciences, Babol, Iran
| | - Bahman Seraj
- Department of Pediatric Dentistry, Dental Research Center, Dentistry Research Institute, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Mostafa Fatemi
- Department of Dental Materials, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Medical Laser Research Center, ACECR, Tehran, Iran
| | - Shirin Taravati
- Department of Pediatric Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| |
Collapse
|
28
|
Influence of root dentin treatment on the push-out bond strength of fiber posts. Odontology 2016; 105:170-177. [PMID: 27206914 DOI: 10.1007/s10266-016-0252-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Accepted: 04/30/2016] [Indexed: 10/21/2022]
Abstract
The aim of the present study was to assess whether different dentin conditioning protocols with different acids [phosphoric acid, ethylene diamine tetra acetic acid (EDTA), and polyacrylic acid (PAA)] influence the bond strength of fiber posts along the radicular depth when luted with self-adhesive resin cement. Twenty single-rooted teeth were randomly divided into four experimental groups (n = 5) according to dentin treatment: Group 1: no treatment; Group 2: etching with 35 % phosphoric acid for 10 s; Group 3: 17 % EDTA application for 60 s; and Group 4: conditioning with 25 % PAA for 30 s. RelyX Fiber Posts were luted with the self-adhesive resin cement RelyX Unicem 2 Automix (3M ESPE). Roots were transversally sectioned into nine 1-mm thick specimens, three corresponding to each root third and a push-out test was performed. Data were analyzed by two-way ANOVA and Tukey test (p < 0.05). Failure mode was determined and specimens with representative failures for each group were observed under scanning electron microscopy. According to the results, dentin treatment influenced the bond strength (p < 0.001), whereas the root third did not (p > 0.05). Fiber posts luted after treating dentin with phosphoric acid, and PAA exhibited the highest push-out bond strength values, while the lowest were obtained after EDTA application. Intermediate results were obtained when dentin was not conditioned. In conclusion, the bond strength of the self-adhesive resin cement RelyX Unicem 2 improves when root dentin is treated with 35 % phosphoric acid or 25 % PAA, before fiber posts luting irrespective of the root depth.
Collapse
|
29
|
Uzun İH, Malkoç MA, Keleş A, Öğreten AT. 3D micro-CT analysis of void formations and push-out bonding strength of resin cements used for fiber post cementation. J Adv Prosthodont 2016; 8:101-9. [PMID: 27141253 PMCID: PMC4852261 DOI: 10.4047/jap.2016.8.2.101] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2015] [Revised: 11/09/2015] [Accepted: 11/23/2015] [Indexed: 12/02/2022] Open
Abstract
PURPOSE To investigate the void parameters within the resin cements used for fiber post cementation by micro-CT (µCT) and regional push-out bonding strength. MATERIALS AND METHODS Twenty-one, single and round shaped roots were enlarged with a low-speed drill following by endodontic treatment. The roots were divided into three groups (n=7) and fiber posts were cemented with Maxcem Elite, Multilink N and Superbond C&B resin cements. Specimens were scanned using µCT scanner at resolution of 13.7 µm. The number, area, and volume of voids between dentin and post were evaluated. A method of analysis based on the post segmentation was used, and coronal, middle and apical thirds considered separately. After the µCT analysis, roots were embedded in epoxy resin and sectioned into 2 mm thick slices (63 sections in total). Push-out testing was performed with universal testing device at 0.5 mm/min cross-head speed. Data were analyzed with Kruskal–Wallis and Mann–Whitney U tests (α=.05). RESULTS Overall, significant differences between the resin cements and the post level were observed in the void number, area, and volume (P<.05). Super-Bond C&B showed the most void formation (44.86 ± 22.71). Multilink N showed the least void surface (3.51 ± 2.24 mm2) and volume (0.01 ± 0.01 mm3). Regional push-out bond strength of the cements was not different (P>.05). CONCLUSION µCT proved to be a powerful non-destructive 3D analysis tool for visualizing the void parameters. Multilink N had the lowest void parameters. When efficiency of all cements was evaluated, direct relationship between the post region and push-out bonding strength was not observed.
Collapse
Affiliation(s)
- İsmail Hakkı Uzun
- Department of Prosthodontics, Inonu University Faculty of Dentistry, Malatya, Turkey
| | - Meral Arslan Malkoç
- Department of Prosthodontics, Inonu University Faculty of Dentistry, Malatya, Turkey
| | - Ali Keleş
- Department of Endodontics, 19 Mayıs University Faculty of Dentistry, Samsun, Turkey
| | | |
Collapse
|
30
|
Victorino KR, Kuga MC, Duarte MAH, Cavenago BC, Só MVR, Pereira JR. The effects of chlorhexidine and ethanol on push-out bond strength of fiber posts. J Conserv Dent 2016; 19:96-100. [PMID: 26957803 PMCID: PMC4760025 DOI: 10.4103/0972-0707.173210] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
CONTEXT Irrigation of root canals with chlorhexidine (CHX) and ethanol is common practice to prevent root canal infection during postplacement. However, pretreatment with these solvents may interfere with the bond strength of posts. AIMS This study aimed to evaluate if root dentin pretreatment using CHX and/or ethanol influences the push-out bond strength of fiber-reinforced composite resin (FRCR) posts. MATERIALS AND METHODS Fifty space posts prepared in endodontically treated extracted human canine roots were randomly divided into five groups (n = 10) according to the dentin pretreatment: Distilled water (W); 1% CHX diacetate solution (1C); CHX diacetate + 99% ethanol (1CE); 99% ethanol (E); and 2% CHX digluconate solution (2C). After pretreatment, the adhesive system (Peak Universal Bond; Ultradent, South Jordan, UT, USA) was applied in the root dentin and the FRCR was cemented with resin cement. Then, horizontal slices of 2 mm were obtained from each root third and the push-out bond strength was assessed. Statistical analysis was done using analysis of variance (ANOVA) and Tukey's tests (P = 0.05). RESULTS At all thirds, 1CE and E groups presented similar push-out bond strength values (P > 0.05), which were higher than the other groups (P < 0.05). W, 1C, and 2C groups were similar (P > 0.05). CONCLUSION The root dentin pretreatment with ethanol, alone or mixed with CHX diacetate increased the bond strength of FRCR luted with resin cement.
Collapse
Affiliation(s)
- Keli Regina Victorino
- Department of Endodontics, Araraquara Dental School, São Paulo State University, Araraquara, Brazil
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, Araraquara Dental School, São Paulo State University, Araraquara, Brazil
| | | | - Bruno Cavalini Cavenago
- Department of Endodontics, Bauru Dental School, University of São Paulo, Bauru, São Paulo, Brazil
| | - Marcus Vinicius Reis Só
- Department of Conservative Dentistry, Federal University of Rio Grande do Sul, Rio Grande do Sul, Brazil
| | - Jefferson Ricardo Pereira
- Department of Prosthodontics, Dental School, University of Southern Santa Catarina, Tubarão, Santa Catarina, Brazil
| |
Collapse
|
31
|
Conde DM, Rodrigues VP, Carvalho Souza SDF, Bauer JRO, Bramante FDS, Linares Lima SN, Filho EMM, Bandeca MC, de Mendonça AAM, Lima DM. Influence of Relining Post on the Bond Strength of Resin Cements. J Contemp Dent Pract 2015; 16:559-564. [PMID: 26329411 DOI: 10.5005/jp-journals-10024-1722] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This study evaluated the influence of relining fiber posts on the bond strength (BS) of resin cements in the root canal. Forty bovine teeth were divided in four groups (n = 10): G1 (ARC)-fiber post cemented with resin cement RelyX ARC; G2 (ARC+Z350)-relined fiber post cemented with RelyX ARC; G3 (U200)-fiber post cemented with self-adhesive cement RelyX U200; G4 (U200+Z350)-relined fiber post cemented with RelyX U200. The roots were sectioned in six 1.2-mm slices and the push-out test was performed. Data were analyzed by three-way analysis of variance (ANOVA), and Tukey's test (a = 0.05). For the conventional resin cement, there was no significant difference between groups G1-ARC (15.5 ± 3.8) and G2-ARC+Z350 (16.1 ± 4.5). For the self-adhesive cement, the results revealed higher BS values for relined posts G4-U200 + Z350 (19.9 ± 7.9) as compared to non-relined posts G3-U200 (14.4 ± 4.5). For both cements, in groups of relined posts, the apical and the cervical thirds presented similar BS. Relining enhances the performance of the self-adhesive resin cement, and the interaction between relining and root third influences the BS to the conventional resin cement.
Collapse
Affiliation(s)
- Daniele Meira Conde
- Department of Dentistry, Federal University of Maranhao Avenida dos Portugueses, Bacanga, Sao Luis, Maranhao Brazil
| | - Vandilson Pinheiro Rodrigues
- Department of Dentistry, Federal University of Maranhao Avenida dos Portugueses, Bacanga, Sao Luis, Maranhao Brazil
| | | | - José Roberto Oliveira Bauer
- Department of Dentistry, Federal University of Maranhao Avenida dos Portugueses, Bacanga, Sao Luis, Maranhao Brazil
| | | | | | | | | | | | - Darlon Martins Lima
- Professor, Department of Dentistry, Federal University of Maranhao Avenida dos Portugueses, 1966, Bacanga, Sao Luis, Maranhao Brazil, CEP 65080-805, Phone: +55 98 3272-8577, e-mail:
| |
Collapse
|
32
|
Skupien JA, Sarkis-Onofre R, Cenci MS, Moraes RRD, Pereira-Cenci T. A systematic review of factors associated with the retention of glass fiber posts. Braz Oral Res 2015; 29:S1806-83242015000100401. [PMID: 26083089 DOI: 10.1590/1807-3107bor-2015.vol29.0074] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2014] [Accepted: 02/18/2015] [Indexed: 11/22/2022] Open
Abstract
This study aimed to identify factors that can affect the retention of glass fiber posts to intra-radicular dentin based on in vitro studies that compared the bond strength (BS) of GFPs cemented with resin cements. Searches were carried out in PubMed and Scopus until December 2013. Bond strength values and variables as type of tooth, presence of endodontic treatment, pretreatment of the post, type of bonding agent (if present), type of cement and mode of cement application were extracted from the 34 included studies. A linear regression model was used to evaluate the influence of these parameters on BS. The presence of endodontic treatment decreased the BS values in 22.7% considering the pooled data (p = 0.013). For regular cement, cleaning the post increased BS when compared to silane application without cleaning (p = 0.032), considering cleaning as ethanol, air abrasion, or phosphoric acid application. Applying the cement around the post and into root canal decreased the resistance compared to only around the post (p = 0.02) or only into root canal (p = 0.041), on the other hand, no difference was found for self-adhesive resin cement for the same comparisons (p = 0.858 and p = 0.067). Endodontic treatment, method of cement application, and post pretreatment are factors that might significantly affect the retention of glass-fiber posts into root canals mainly when cemented with regular resin cement. Self-adhesive resin cements were found to be less technique-sensitive to luting procedures as compared with regular resin cements.
Collapse
Affiliation(s)
| | | | - Maximiliano Sérgio Cenci
- Department of Restorative Dentistry, Dental School, Universidade Federal de Pelotas, Pelotas, RS, Brazil
| | - Rafael Ratto de Moraes
- Department of Restorative Dentistry, Dental School, Universidade Federal de Pelotas, Pelotas, RS, Brazil
| | - Tatiana Pereira-Cenci
- Department of Prosthodontics, Dental School, Universidade Federal de Pelotas, Pelotas, RS, Brazil
| |
Collapse
|
33
|
Parisi C, Valandro LF, Ciocca L, Gatto MRA, Baldissara P. Clinical outcomes and success rates of quartz fiber post restorations: A retrospective study. J Prosthet Dent 2015; 114:367-72. [PMID: 26013066 DOI: 10.1016/j.prosdent.2015.03.011] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Revised: 03/07/2015] [Accepted: 03/09/2015] [Indexed: 10/23/2022]
Abstract
STATEMENT OF PROBLEM Cast metal posts and dowels are inherently dark and, when metal-free restorations are used, could impair the definitive esthetic appearance. Quartz fiber posts could represent a reliable choice for restoring abutment teeth. PURPOSE The purpose of this study was to evaluate the long-term success rate of teeth restored with quartz fiber posts and fixed dental prostheses (FDPs). MATERIAL AND METHODS Ninety-nine teeth restored with 114 quartz fiber posts and FDPs were evaluated. The evaluation time ranged from 7 months to 9.25 years. The Kaplan-Meier method was used to obtain success curves. The influence of the tooth location, definitive restoration, and failure pattern upon the success function was analyzed with the log-rank test. The Cox regression test was used to evaluate possible predictors among the interactions of the observed parameters. RESULTS The success rate of the restorations was 85.86% in a mean period of 5.88 ±1.37 years, with an estimated success probability of 85% at 6.17 years. The statistical analysis identified the factors related to the arch (P=.045) and type of definitive restoration (P=.021) as significantly associated with success. Post debonding was the most frequent failure mode, followed by endodontic failure, with the latter not necessarily being related to the post itself. No root fractures were recorded. Twelve teeth out of the 14 that failed were restored again, bringing the overall survival rate of the teeth to 98%. CONCLUSIONS The rehabilitation of abutment teeth with quartz fiber posts can be considered a reliable procedure; however, adhesive techniques and luting materials require improvement.
Collapse
Affiliation(s)
- Candida Parisi
- Tutor, Department of Biomedical Sciences and neuromotor (DIBINEM), School of Dentistry, Unit of Odontostomatological Sciences, Division of Prosthodontics, Alma Mater Studiorum, University of Bologna, Bologna, Italy.
| | - Luiz F Valandro
- Professor, Faculty of Dentistry, Federal University of Santa Maria, Rio Grande do Sul, Brazil
| | - Leonardo Ciocca
- Researcher, Department of Biomedical Sciences and neuromotor (DIBINEM), School of Dentistry, Unit of Odontostomatological Sciences - Division of Prosthodontics, Alma Mater Studiorum, University of Bologna, Bologna, Italy
| | - Maria R A Gatto
- Aggregate Professor, Medical Statistics Course, Department of Biomedical Sciences and neuromotor (DIBINEM), Unit of Odontostomatological Sciences, Division of Orthodontics and Gnathology, Alma Mater Studiorum, University of Bologna, Bologna, Italy
| | - Paolo Baldissara
- Aggregate Professor, Dental Materials Course; Department of Biomedical Sciences and neuromotor (DIBINEM), Unit of Odontostomatological Sciences, Division of Prosthodontics, Alma Mater Studiorum, University of Bologna, Bologna, Italy
| |
Collapse
|
34
|
Khoroushi M, Mazaheri H, Tarighi P, Samimi P, Khalighinejad N. Effect of antioxidants on push-out bond strength of hydrogen peroxide treated glass fiber posts bonded with two types of resin cement. Restor Dent Endod 2014; 39:303-9. [PMID: 25383350 PMCID: PMC4223101 DOI: 10.5395/rde.2014.39.4.303] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2014] [Accepted: 07/27/2014] [Indexed: 12/02/2022] Open
Abstract
Objectives Hydrogen peroxide (H2O2) surface treatment of fiber posts has been reported to increase bond strength of fiber posts to resin cements. However, residual oxygen radicals might jeopardize the bonding procedure. This study examined the effect of three antioxidant agents on the bond strength of fiber posts to conventional and self-adhesive resin cements. Materials and Methods Post spaces were prepared in forty human maxillary second premolars. Posts were divided into five groups of 8 each: G1 (control), no pre-treatment; G2, 10% H2O2 pre-treatment; G3, G4 and G5. After H2O2 application, Hesperidin (HES), Sodium Ascorbate (SA) or Rosmarinic acid (RA) was applied on each group respectively. In each group four posts were cemented with Duo-Link conventional resin cement and the others with self-adhesive BisCem cement. Push-out test was performed and data were analyzed using 2-way ANOVA and tukey's post-hoc test (α = 0.05). Results There was a statistically significant interaction between the cement type and post surface treatment on push-out bond strength of fiber posts (p < 0.001, F = 16). Also it was shown that different posts' surface treatments significantly affect the push-out bond strength of fiber posts (p = 0.001). H2O2 treated posts (G2) and control posts (G1) cemented with Duo-link showed the highest (15.96 ± 5.07MPa) and lowest bond strengths (6.79 ± 3.94) respectively. Conclusions It was concluded that H2O2 surface treatment might enhance the bond strength of fiber posts cemented with conventional resin cements. The effect of antioxidants as post's surface treatment agents depends on the characteristics of resin cements used for bonding procedure.
Collapse
Affiliation(s)
- Maryam Khoroushi
- Department of Operative Dentistry, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran. ; Dental Materials Research Center, Isfahan University of Medical Science, Isfahan, Iran
| | - Hamid Mazaheri
- Dental Materials Research Center, Isfahan University of Medical Science, Isfahan, Iran
| | - Pardis Tarighi
- Department of Operative Dentistry, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran. ; Department of Operative Dentistry and Torabinejad Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Pouran Samimi
- Department of Operative Dentistry, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Navid Khalighinejad
- Dental Materials Research Center, Isfahan University of Medical Science, Isfahan, Iran
| |
Collapse
|
35
|
Pereira JR, Rosa RAD, Só MVR, Afonso D, Kuga MC, Honório HM, Valle ALD, Vidotti HA. Push-out bond strength of fiber posts to root dentin using glass ionomer and resin modified glass ionomer cements. J Appl Oral Sci 2014; 22:390-6. [PMID: 25004052 PMCID: PMC4245750 DOI: 10.1590/1678-775720130466] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Accepted: 03/31/2014] [Indexed: 11/22/2022] Open
Abstract
Objective The purpose of this study was to assess the push-out bond strength of glass fiber
posts to root dentin after cementation with glass ionomer (GICs) and
resin-modified glass ionomer cements (RMGICs). Material and Methods Fifty human maxillary canines were transversally sectioned at 15 mm from the apex.
Canals were prepared with a step back technique until the application of a #55
K-file and filled. Post spaces were prepared and specimens were divided into five
groups according to the cement used for post cementation: Luting & Lining
Cement; Fuji II LC Improved; RelyX Luting; Ketac Cem; and Ionoseal. After
cementation of the glass fiber posts, all roots were stored at 100% humidity until
testing. For push-out test, 1-mm thick slices were produced. The push-out test was
performed in a universal testing machine at a crosshead speed of 0.5 mm/minute and
the values (MPa) were analyzed by Kolmogorov-Smirnov and Levene's tests and by
two-way ANOVA and Tukey's post hoc test at a significance level
of 5%. Results Fiber posts cemented using Luting & Lining Cement, Fuji II LC Improved, and
Ketac Cem presented the highest bond strength to root dentin, followed by RelyX
Luting. Ionoseal presented the lowest bond strength values (P>0.05). The post
level did not influence the bond strength of fiber posts to root dentin (P=0.148).
The major cause of failure was cohesive at the cement for all GICs and RMGICs. Conclusions Except for Ionoseal, all cements provided satisfactory bond strength values.
Collapse
Affiliation(s)
| | - Ricardo Abreu da Rosa
- Department of Conservative Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - Marcus Vinícius Reis Só
- Department of Conservative Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - Daniele Afonso
- University of Southern Santa Catarina, Tubarão, SC, Brazil
| | - Milton Carlos Kuga
- Department of Endodontics, School of Dentistry, Univ. Estadual Paulista, Araraquara, SP, Brazil
| | - Heitor Marques Honório
- Department of Pediatric Dentistry, Orthodontics and Community Health, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - Accácio Lins do Valle
- Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - Hugo Alberto Vidotti
- Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| |
Collapse
|
36
|
de Araújo DFG, Chaves LP, Bim Júnior O, Pimentel Garcia FC, Ishikiriama SK, Honório HM, Wang L. Influence of 2% chlorhexidine digluconate on bond strength of a glass-fibre post luted with resin or glass-ionomer based cement. J Dent 2014; 42:735-41. [DOI: 10.1016/j.jdent.2014.02.019] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2013] [Revised: 02/19/2014] [Accepted: 02/21/2014] [Indexed: 11/30/2022] Open
|
37
|
Pereira JR, do Valle AL, Shiratori FK, Ghizoni JS, Bonfante EA. The effect of post material on the characteristic strength of fatigued endodontically treated teeth. J Prosthet Dent 2014; 112:1225-30. [PMID: 24836285 DOI: 10.1016/j.prosdent.2014.03.014] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2013] [Revised: 03/25/2014] [Accepted: 03/26/2014] [Indexed: 10/25/2022]
Abstract
STATEMENT OF PROBLEM The biomechanical properties of post systems may become more important as the amount of remaining tooth structure decreases, thus different materials may influence the characteristic strength of fatigued endodontically treated teeth. PURPOSE The purpose of this study was to assess the characteristic strength and probability of survival of endodontically treated teeth restored with different intraradicular post systems. MATERIAL AND METHODS Forty human maxillary canines with similar root lengths were randomly divided into 4 groups (n=10): cast post and core, stainless-steel prefabricated post, carbon-fiber post, and glass-fiber post. Cores and metallic crowns were fabricated for all specimens. Restored teeth were exposed to mechanical fatigue (250,000 cycles) in a controlled chewing simulator. Each intact specimen was mounted in a special device and aligned at a 45-degree angle to the long axis of the tooth. A universal testing machine was used to apply a static load at a crosshead speed of 0.5 mm/min until specimen failure. The maximum value was recorded in newtons (N). Probability Weibull curves (2-sided 90% confidence bounds) were calculated for each group, and a probability of survival as a function of load at failure was plotted for the groups. RESULTS A significantly higher characteristic strength was observed for groups carbon-fiber post (755.82 N) and cast post and core (750.6 N) (P<.05) compared with glass-fiber post (461.35 N) and stainless-steel prefabricated post (524.78 N) groups. All the roots in the cast post and core group demonstrated catastrophic fracture, whereas the remaining groups had no root fractures. CONCLUSIONS Prefabricated posts made of glass fiber and stainless steel showed significantly lower characteristic strength and probability of survival than cast post and core, whereas crowns with carbon-fiber posts presented a single load similar to the fracture values of cast posts.
Collapse
Affiliation(s)
- Jefferson Ricardo Pereira
- Associate Clinical Professor and Researcher Coordinator, Department of Prosthodontics, Dental School, University of Southern Santa Catarina, Tubarão, Brazil.
| | - Accácio Lins do Valle
- Associated Clinical Professor, Department of Prosthodontics, Bauru Dental School, University of São Paulo, São Paulo, Brazil
| | | | - Janaina Salomon Ghizoni
- Associate Clinical Professor and Researcher Coordinator, Department of Prosthodontics, Dental School, University of Southern Santa Catarina, Tubarão, Brazil
| | - Estevam Augusto Bonfante
- Associate Clinical Professor, Department of Prosthodontics, Bauru Dental School, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
38
|
The influence of different cements on the pull-out bond strength of fiber posts. J Prosthet Dent 2014; 112:59-63. [PMID: 24423461 DOI: 10.1016/j.prosdent.2013.10.009] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Revised: 10/01/2013] [Accepted: 10/05/2013] [Indexed: 11/20/2022]
Abstract
STATEMENT OF PROBLEM Glass fiber posts are commonly used to provide adequate support and retention for the restoration of endodontically treated teeth, but their resistance to dislodgement depends on their adhesion to root dentin. PURPOSE The purpose of this study was to assess the effect of cement type on the pull-out bond strength of fiber posts. MATERIAL AND METHODS Seventy maxillary canines were endodontically treated and then divided into 7 groups according to the cement used for fiber post cementation as follows (n = 10): RelyX Unicem, BisCem, RelyX Luting 2, RelyX ARC, Panavia F, Enforce, and Allcem. The specimens were subjected to a pull-out bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. The results, in newtons, were analyzed with 1-way ANOVA and the Tukey post hoc test (α = .05). RESULTS RelyX Unicem (472.3 ± 8.9 N), BisCem (506.6 ± 9.2 N), RelyX ARC (498.0 ± 8.2 N), Panavia F (502.3 ± 7.0 N), and Allcem (470.0 ± 11.3 N) presented significantly higher bond strength than RelyX Luting 2 (241.8 ± 9.70 N) and Enforce (309.5 ± 6.3 N) cements (mean ± SD; P < .05). CONCLUSIONS Except for Enforce, all resin cements produced pull-out bond strength values twice that of resin modified glass ionomer cement. However, all cements promoted adequate retention to fiber posts to withstand functional loads.
Collapse
|