Effects of Daily Activities and Position on Kinematics and Contact Mechanics of Dual Mobility Hip Implant. JOURNAL OF HEALTHCARE ENGINEERING 2020; 2020:8103523. [PMID: 32257086 PMCID: PMC7097768 DOI: 10.1155/2020/8103523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Revised: 02/10/2020] [Accepted: 02/18/2020] [Indexed: 11/21/2022]
Abstract
Dual mobility hip implants have been widely introduced to overcome dislocation in recent years. However, the potential influence of different gaits on kinematics and contact mechanics for dual mobility hip implants is still unclear. Furthermore, a large range of motion coupling with the implant position, especially high inclination or anteversion angle, may result in poor kinematics and contact mechanics. A previously developed dynamic finite element method was adopted in this study to examine the kinematics and corresponding stability of dual mobility hip implants under different gaits coupling with different inclinations or anteversion angles. The results showed only inner relative sliding under knee-bending for dual mobility hip implants under moderate inclination and anteversion angles, whereas an anteversion angle of 25° induced both impingement and consequent relative sliding of the outer articulation. However, the impingement (between the stem neck and the liner inner rim) indeed happened under stair-climbing and sitting-down/stand-up as well as combined movements when inclination and anteversion angles were set as 45° and 0°, respectively, and this finally led to relative sliding at the outer articulation. A high inclination angle did not worsen both the impingement and related outer sliding compared to modest inclination and anteversion angles of the liner, but a high anteversion angle prolonged the period of both the impingement and the outer relative sliding. The extreme motions and high anteversion angles are hardly inevitable, and they indeed lead to motions at both articulations for dual mobility hip implants.
Collapse
|
2
|
Schmidt A, Batailler C, Fary C, Servien E, Lustig S. Dual Mobility Cups in Revision Total Hip Arthroplasty: Efficient Strategy to Decrease Dislocation Risk. J Arthroplasty 2020; 35:500-507. [PMID: 31563399 DOI: 10.1016/j.arth.2019.08.060] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 08/11/2019] [Accepted: 08/27/2019] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Revision total hip arthroplasty (rTHA) is a challenging surgery with a higher rate of complications than primary arthroplasty, particularly instability and aseptic loosening. The purpose of this study is to compare dual mobility cup (DMC) and standard mobility cup (SMC) in all rTHAs performed at our institution over a decade with a 1 year minimum follow-up. METHODS Two hundred ninety-five rTHAs (acetabular only and bipolar revisions) between 2006 and 2016 were retrospectively reviewed. These were divided into those with a DMC (184 revisions) or SMC (111 revisions). Dislocation and complications requiring re-revision were reported. RESULTS The rTHA mean age was 69 years ± 13.9 (19-92) and the mean follow-up was 2.3 years. Dislocation risk was statistically lower (P = .01) with a DMC (3.8%; 7/184) than with an SMC (13.5%; 15/111). DMC required re-rTHA in 24/184 (13%) for any reason compared to SMC in 19/111 (17.1%) (P = .34). There was no significant difference in early aseptic loosening (P = .28) between the 2 groups. For young patients (≤55 years), results were similar with a lower dislocation rate in the DMC group (P = .24) and no increased risk of early aseptic loosening (P = .49). CONCLUSION This study demonstrates that for all rTHA indications DMC compared to SMC has a significantly decreased risk of postoperative dislocation without risk of early aseptic loosening at medium term follow-up. The use of DMC in rTHA is an important consideration particularly with the predicted increased incidence of both primary and revision THA globally.
Collapse
Affiliation(s)
- Axel Schmidt
- Orthopaedic Department, Lyon North University Hospital, Lyon, France
| | - Cécile Batailler
- Orthopaedic Department, Lyon North University Hospital, Lyon, France
| | - Camdon Fary
- Department of Orthopaedic Surgery, Western Health, Melbourne, Australia; Department of Surgery, The University of Melbourne, Victoria, Australia
| | - Elvire Servien
- Orthopaedic Department, Lyon North University Hospital, Lyon, France
| | - Sébastien Lustig
- Orthopaedic Department, Lyon North University Hospital, Lyon, France
| |
Collapse
|
3
|
Abstract
Hip instability following total hip arthroplasty (THA) remains a major challenge and is one of the main causes of revision surgery. Dual mobility (DM) implants have been introduced to try to overcome this problem. The DM design consists of a small femoral head captive and mobile within a polyethylene liner. Numerous studies have shown that DM implants reduce the rate of dislocation compared to fixed-bearing inserts. Early designs for DM implants had problems with wear and intra-prosthetic dislocations, so their use was restricted to limited indications. The results of the latest generation of DM prostheses demonstrate that these problems have been overcome. Given the results of these studies presented in this review, surgeons may now consider DM THA for a wider patient selection.
Cite this article: EFORT Open Rev 2019;4:541-547. DOI: 10.1302/2058-5241.4.180045
Collapse
Affiliation(s)
- William G Blakeney
- Department of Surgery, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hôpital Maisonneuve Rosemont, Montréal, Québec, Canada.,Department of Surgery, Albany Health Campus, Albany, Australia
| | | | - Pascal-André Vendittoli
- Department of Surgery, Albany Health Campus, Albany, Australia.,Department of Surgery, Université de Montréal, Montréal, Québec, Canada
| |
Collapse
|
4
|
Boyer B, Neri T, Geringer J, Lamotte A, Philippot R, Farizon F. Letter to the Editor on "Contemporary Dual Mobility Head Penetration at Five Years: Concern for the Additional Convex Bearing Surface?". J Arthroplasty 2018; 33:3363-3365. [PMID: 29980420 DOI: 10.1016/j.arth.2018.06.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Accepted: 06/05/2018] [Indexed: 02/01/2023] Open
Affiliation(s)
- Bertrand Boyer
- INSERM, U1059, Saint Etienne, France; Université de Lyon, Saint Etienne, France; CHU Saint Etienne, Hôpital Nord, Service d'Orthopédie, Saint Etienne, France
| | - Thomas Neri
- Université de Lyon, Saint Etienne, France; CHU Saint Etienne, Hôpital Nord, Service d'Orthopédie, Saint Etienne, France; EA 7424 Inter-University Laboratory of Human Movement Science, University of Lyon, University Jean Monnet, Saint Etienne, France
| | | | - Antoine Lamotte
- Université de Lyon, Saint Etienne, France; CHU Saint Etienne, Hôpital Nord, Service d'Orthopédie, Saint Etienne, France
| | - Remi Philippot
- Université de Lyon, Saint Etienne, France; CHU Saint Etienne, Hôpital Nord, Service d'Orthopédie, Saint Etienne, France; EA 7424 Inter-University Laboratory of Human Movement Science, University of Lyon, University Jean Monnet, Saint Etienne, France
| | - Frederic Farizon
- INSERM, U1059, Saint Etienne, France; Université de Lyon, Saint Etienne, France; CHU Saint Etienne, Hôpital Nord, Service d'Orthopédie, Saint Etienne, France
| |
Collapse
|
5
|
Abstract
Hip instability after total joint arthroplasty is a devastating complication. Appropriate management of instability is a challenge. Three components that are commonly used in these challenging scenarios are constrained liners, constrained tripolar components, and nonconstrained tripolar components. The biomaterials and biomechanics of these devices vary. Surgeons must take into account the risks associated with each of these components and some surgical pearls for their use. A thorough review of the recent literature allows comparison of results addressing the short-, medium-, and long-term survival of each component. Constraining devices are a good option when used in salvage procedures in elderly and/or low-demand patients with hip instability. However, constraining devices should not be used to correct deficiencies in surgical technique or implant placement.
Collapse
|
6
|
Murphy EP, Fenelon C, Russell S, Condon F. Cause of irreducible dislocation of a re-revision THR. BMJ Case Rep 2018; 2018:bcr-2017-223072. [PMID: 29866666 DOI: 10.1136/bcr-2017-223072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Instability or recurrent dislocations are a common reason for revision of total hip replacements (THRs). Dual-mobility constructs can help improve stability by increasing the femoral head jump distance. These constructs are used to decrease the risk of re-revision in the setting of recurrent dislocation. This case describes an unusual case of irreducible dislocation of a re-revision THR due to intraprosthetic dislocation. The patient required open reduction and revision of this construct to a tripolar implant. This is important to appreciate from an emergency medicine point of view as repeated attempts at reduction will be fruitless and may result in a femur fracture. This particular type of dislocation is very rare. Perioperative considerations should include early referral to the orthopaedic team for reduction in theatre, and having a low threshold for open reduction. Revision options should be available when bringing a case like this to the operating theatre.
Collapse
Affiliation(s)
| | | | - Shane Russell
- Department of Trauma and Orthopaedics, Limerick University Hospital, Limerick, Ireland
| | - Finbarr Condon
- Department of Trauma and Orthopaedics, Limerick University Hospital, Limerick, Ireland
| |
Collapse
|
7
|
Dual mobility canine total hip prosthesis: Implant characteristics and surgical procedure. Vet Comp Orthop Traumatol 2017; 25:506-10. [DOI: 10.3415/vcot-11-11-0157] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2011] [Accepted: 08/22/2012] [Indexed: 11/17/2022]
Abstract
SummaryProsthetic dislocation is one of the most common complications after canine hip replacement. The use of dual mobility acetabular components has been shown to reduce the rate of dislocation in first intent hip replacement in human patients who are at high risk for dislocation. In such implants, a mobile polyethylene liner articulates on one side with a metallic acetabular component and on the other side with a metallic prosthetic head. A dual mobility cemented acetabular component has been designed for use in dogs, and is available for use in association with a previously designed modular femoral component. This report describes the characteristics and the procedure for implantation of this implant combination.
Collapse
|
8
|
Abstract
Dislocation remains a common cause of failure after total hip arthroplasty. The limitations of existing approaches to address instability have led to the development of powerfull options: constrained liners, dual mobility and large heads. These implant-related options have proven to be very efficient, but have raised concerns.With constrained liners, restricted range of motion (ROM) is responsible for impingement leading to high likelihood of failure, depending on the design, with various failure modes.Improvements of the bearing materials have addressed some of the concerns about increased volumetric wear of conventional polyethylene and offer an option to reduce instability: large diameter heads have the advantage of increased ROM before impingement, increased head-neck ratio, and jump distance. Highly cross-linked polyethylene helps address the risk for increased wear, and also large heads provide improved stability without the risk of mechanical failures observed with constrained liners. However, the increase of the head size remains limited as reducing the thickness of the liner may lead to fractures. In addition, the jump distance decreases as the cup abduction increases.The dual mobility concept simultaneously attempts to address head-neck ratio, constraint, and jump distance. Despite the need for longer follow-up, concerns raised about potential increased wear and intra-prosthetic dislocation with first generation implants have been addressed with modern designs.With a dramatic increase of the head-neck ratio whilst reducing the risk of mechanical failure or excessive wear, dual mobility THA outperforms large diameter heads and constrained liners at 10 years follow-up. For these reasons, dual mobility continues to gain interest worldwide and is becoming the most popular option to manage instability. Cite this article: Guyen O. Constrained liners, dual mobility or large diameter heads to avoid dislocation in THA. EFORT Open Rev 2016;1:197-204. DOI: 10.1302/2058-5241.1.000054.
Collapse
Affiliation(s)
- Olivier Guyen
- Department of Orthopaedic Surgery, Lausanne University Hospital, Lausanne, Switzerland
| |
Collapse
|
9
|
Gonzalez AI, Bartolone P, Lubbeke A, Dupuis Lozeron E, Peter R, Hoffmeyer P, Christofilopoulos P. Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty. Acta Orthop 2017; 88:18-23. [PMID: 27841712 PMCID: PMC5251258 DOI: 10.1080/17453674.2016.1255482] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period using either the dual-mobility cup or the unipolar cup. Methods - We used a prospective hospital registry-based cohort including all total and cup-only revision THAs performed between 2003 and 2013. The cups used were either dual-mobility or unipolar; the choice was made according to the preference of the surgeon. 316 revision THAs were included. The mean age of the cohort was 69 (25-98) years and 160 THAs (51%) were performed in women. The dual-mobility group (group 1) included 150 THAs (48%) and the mean length of follow-up was 31 (0-128) months. The unipolar group (group 2) included 166 THAs (53%) and the mean length of follow-up was 52 (0-136) months. Results - The incidence of dislocation within 6 months was significantly lower with the dual-mobility cup than with the unipolar cup (2.7% vs. 7.8%). The unadjusted risk ratio (RR) was 0.34 (95% CI: 0.11-1.02) and the adjusted RR was 0.28 (95% CI: 0.09-0.87). The number of patients needed to treat with a dual-mobility cup in order to prevent 1 case of dislocation was 19. The unadjusted incidence rate ratio for all-cause re-revision in the dual-mobility group compared to the unipolar group was 0.6 (95% CI: 0.3-1.4). Interpretation - Use of a dual-mobility rather than a unipolar cup in revision THA reduced the risk of dislocation within 6 months.
Collapse
|
10
|
Zagra L, Caboni E. Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options. INTERNATIONAL ORTHOPAEDICS 2017; 41:661-668. [DOI: 10.1007/s00264-016-3383-0] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2016] [Accepted: 12/19/2016] [Indexed: 01/02/2023]
|
11
|
Dual-mobility arthroplasty failure: a rationale review of causes and technical considerations for revision. INTERNATIONAL ORTHOPAEDICS 2016; 41:481-490. [PMID: 27872981 DOI: 10.1007/s00264-016-3328-7] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2016] [Accepted: 10/17/2016] [Indexed: 12/26/2022]
Abstract
PURPOSE Dual-mobility arthroplasty is an alternative to conventional total hip arthroplasty (THA) in appropriately selected, active adults with degenerative, necrotic or post-traumatic hip disease or with revision hip arthroplasty. Numerous papers have been published with results of dual-mobility arthroplasty, but there have been no comprehensive literature reviews that summarise the most recent findings and help the orthopaedic surgeon facing different scenarios in which revision of one or both components of a dual-mobility arthroplasty is indicated. METHODS We performed a PubMed search for papers published on dual-mobility arthroplasty that provided data on revision and add our experience in order to describe different revision scenarios. We collected data on revision for any reason, for aseptic loosening, for infection, or for dislocation. For each complication, we summarise causes and diagnosis of this complication and describe the direction of possible therapeutic options. RESULTS The dual-mobility arthroplasty offers the benefit of increased stability without compromising clinical outcomes and implant longevity. However, as with conventional arthroplasties, complications are also reported, with the most frequent being cup loosening, dislocation, accelerated wear and infection. Dual-mobility implants also have some specific complications secondary to their specific design, with the presence of a third joint. For example, intraprosthetic dislocation due to retentive failure of the polyethylene (PE) liner on the femoral head is a complication observed exclusively with this type of implant and involves articulation failure between the femoral head and the PE liner. Mechanical conflict with the iliopsoas tendon has also been reported, probably due to femoral head size, cup design, and/or a dysplastic hip. This systematic review of the literature identified several options for treating each complication, and in particular, options regarding conserving or not of one the two articulating devices. CONCLUSIONS These findings can inform discussions relating to risks and benefits of different therapeutic options when performing revision of a dual-mobility arthroplasty.
Collapse
|
12
|
In total hip arthroplasty via the direct anterior approach, a dual-mobility cup prevents dislocation as effectively in hip fracture as in osteoarthritis. INTERNATIONAL ORTHOPAEDICS 2016; 41:491-497. [PMID: 27837328 DOI: 10.1007/s00264-016-3332-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2016] [Accepted: 10/31/2016] [Indexed: 01/24/2023]
Abstract
PURPOSE The main purpose of this study was to compare the outcome of total hip arthroplasty (THA) via the direct anterior approach (DAA) using a dual-mobility cup (DMC) in patients with femoral neck fracture to those in patients undergoing elective THA for osteoarthritis. PATIENTS AND METHODS We retrospectively investigated 40 hips with femoral neck fracture (group A), and 81 hips with osteoarthritis (group B). THA via the DAA using the DMC was performed in both groups. A primary/secondary outcome variable were the presence of dislocation/operative time, intra- and/or peri-operative complication, and mortality. RESULTS Dislocation did not occur in either group. The complication rate was slightly higher in group A than in group B, but not statistically significant. CONCLUSION THA with the DMC using the DAA was as effective for femoral neck facture as it was for elective THA in patients with osteoarthritis.
Collapse
|
13
|
Figueras G, Planell RV, Fernàndez RS, Biayna JC. Revision of Metal-on-metal Hip Arthroplasty with Well Fixed and Positioned Acetabular Component Using a Dual-mobility Head and Review of Literature. Open Orthop J 2016; 10:512-521. [PMID: 27857822 PMCID: PMC5093867 DOI: 10.2174/1874325001610010512] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2016] [Revised: 09/20/2016] [Accepted: 10/05/2016] [Indexed: 02/08/2023] Open
Abstract
Background: As a consequence of use of metal-on-metal hip arthroplasties some patients have precised revision for pain or metal hipersensivity reactions among other causes. We propose to salvage monoblock acetabular component and femoral component using a dual-mobility head and perform a lower morbidity operation in young patients preserving host bone stock in cases with well fixed and positioned components. Objective: (1) What clinical problems have been reported in patients with Metal-on-metal hip arthroplasties? (2) Could the tribocorrosion potentially cause a fracture of neck femoral component? (3) Can be the dual-mobility head a recourse in metal-on-metal hip revision? Methods: Ten patients were revised for pain or/and raised Cobalt/Chromium levels between August 2012 and December 2015. In three cases femoral neck component was fractured and femoral revision was necessary. In four hips, acetabular and femoral components could be maintained. Age, body index mass, ion levels, acetabular position, size of acetabular component and femoral head, approach, blood transfunsion and time of hospitalization were analized. Results: At a mean follow-up of 25,6 months (6 to 45) the mean postoperative HHS was 92. It was not statistically significant because several patients were low sintomatic before surgery, but had raised Cobalt/Chromium levels in the blood. All patients had near-normal levels of Cobalt/Chromium during the first 6 months after revision surgery. No relevant complications were reported. Conclusion: The use of dual-mobility head can be an acceptable option to revise metal-on-metal arthroplasties correctly oriented with abscence of loosening or infection signs and keeping bone stock in young patients.
Collapse
Affiliation(s)
- Guillem Figueras
- Fundació Althaia, Xarxa Assistencial Universitària de Manresa, Traumatology and Orthopedic Surgery Department, C/Dr Joan Soler S/N 08243 Manresa, (93-8759300), Spain
| | - Ramón Vives Planell
- Fundació Althaia, Xarxa Assistencial Universitària de Manresa, Traumatology and Orthopedic Surgery Department, C/Dr Joan Soler S/N 08243 Manresa, (93-8759300), Spain
| | - Ramón Serra Fernàndez
- Fundació Althaia, Xarxa Assistencial Universitària de Manresa, Traumatology and Orthopedic Surgery Department, C/Dr Joan Soler S/N 08243 Manresa, (93-8759300), Spain
| | - Joan Camí Biayna
- Fundació Althaia, Xarxa Assistencial Universitària de Manresa, Traumatology and Orthopedic Surgery Department, C/Dr Joan Soler S/N 08243 Manresa, (93-8759300), Spain
| |
Collapse
|
14
|
Abstract
Dual mobility cups have two points of articulation, one between the shell and the polyethylene (external bearing) and one between the polyethylene and the femoral head (internal bearing). Movement occurs at the inner bearing; the outer bearing only moves at extremes of movement. Dislocation after total hip arthroplasty (THA) is a cause of much morbidity and its treatment has significant cost implications. Dual mobility cups provide an increased range of movement and a may reduce the risk of dislocation. This paper reviews the use of these cups in THA, particularly where stability is an issue. Dual mobility cups may be of benefit in primary THA in patients at a high risk of dislocation, such as those who are older with increased comorbidities and a higher American Association of Anesthesiology grade and those with a neuromuscular disease. They may be used at revision surgery where the risk of dislocation is high, such as in patients with many prior dislocations, or those with abductor deficiency. They may also be used in THA for displaced fractures of the femoral neck, which has a notoriously high rate of dislocation.
Collapse
Affiliation(s)
- L Matsen Ko
- Rothman Institute Orthopaedics, Egg Harbor Township, New Jersey, 08234, USA
| | - W J Hozack
- Rothman Institute Orthopaedics, Egg Harbor Township, New Jersey, 08234, USA
| |
Collapse
|
15
|
Gao Y, Chai W, Wang L, Wang M, Jin Z. Effect of friction and clearance on kinematics and contact mechanics of dual mobility hip implant. Proc Inst Mech Eng H 2015; 230:39-49. [PMID: 26586527 DOI: 10.1177/0954411915617198] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2015] [Accepted: 10/20/2015] [Indexed: 11/15/2022]
Abstract
The dual mobility hip implant has been introduced recently and increasingly used in total hip replacement to maintain the stability and reduce the risk of post-surgery dislocation. However, the kinematics and contact mechanisms of dual mobility hip implants have not been investigated in detail in the literature. Therefore, finite element method was adopted in this study to investigate dynamics and contact mechanics of a typical metal-on-polymer dual mobility hip implant under different friction coefficient ratios between the inner and the outer articulations and clearances/interferences between the ultra-high-molecular-weight polyethylene liner and the metal back shell. A critical ratio of friction coefficients between the two pairs of contact interfaces was found to mainly determine the rotating surfaces. Furthermore, an initial clearance between the liner and the back shell facilitated the rotation of the liner while an initial interference prevented such a motion at the outer articulating interface. In addition, the contact area and the sliding distance at the outer articulating surface were markedly greater than those at the inner cup-head interface, potentially leading to extensive wear at the outer surface of the liner.
Collapse
Affiliation(s)
- Yongchang Gao
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Wei Chai
- Department of Orthopaedics, General Hospital of Chinese People's Liberation Army, Beijing, China
| | - Ling Wang
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Manyi Wang
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Zhongmin Jin
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| |
Collapse
|
16
|
Vasukutty NL, Middleton RG, Young P, Uzoigwe C, Barkham B, Yusoff S, Minhas THA. A double mobility acetabular implant for primary hip arthroplasty in patients at high risk of dislocation. Ann R Coll Surg Engl 2015; 96:597-601. [PMID: 25350182 DOI: 10.1308/003588414x14055925058391] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
INTRODUCTION Dislocation following total hip replacement continues to be a problem for which no completely satisfactory solution has been found. Several methods have been proposed to reduce the incidence of hip dislocations with varying degrees of success, including elevated rim liners, constrained liners and large diameter bearings. We present our experience with the double mobility acetabular component in patients at high risk of instability. METHODS This was a retrospective review of 65 primary total hip arthroplasties in 55 patients (15 men, 40 women), performed between October 2005 and November 2009. The majority (80%) of patients had at least two and 26% had at least three risk factors for instability. The mean age was 76 years (range: 44-92 years). The patients were followed up for a mean duration of 60 months (range: 36-85 months). RESULTS Fourteen patients died and one was lost to follow-up, leaving fifty hips for final assessment. Until the final follow-up appointment, no patients had dislocation and none required revision surgery. The mean Oxford hip score improved from 45.0 to 26.5 (p<0.0001). The mean Merle d'Aubigné pain score improved from 1.4 to 4.9 (p<0.0001), the walking score from 2.3 to 3.1 (p<0.07) and the absolute hip function score from 5.4 to 10.8 (p<0.0001). There were no clinical or radiographic signs of loosening. CONCLUSIONS The double mobility acetabular component was successful at preventing dislocation during early to medium-term follow-up. However, as data are still lacking with regard to polyethylene wear rates at the additional bearing surface, it would be prudent to restrict the use of this implant to selected patients at high risk of instability.
Collapse
Affiliation(s)
- N L Vasukutty
- Pilgrim Hospital, Boston, Lincolnshire NHS Trust, UK
| | | | | | | | | | | | | |
Collapse
|
17
|
Obesity is no longer a risk factor for dislocation after total hip arthroplasty with a double-mobility cup. INTERNATIONAL ORTHOPAEDICS 2014; 39:1251-8. [DOI: 10.1007/s00264-014-2612-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2014] [Accepted: 11/21/2014] [Indexed: 12/19/2022]
|
18
|
Epinette JA, Béracassat R, Tracol P, Pagazani G, Vandenbussche E. Are modern dual mobility cups a valuable option in reducing instability after primary hip arthroplasty, even in younger patients? J Arthroplasty 2014; 29:1323-8. [PMID: 24444567 DOI: 10.1016/j.arth.2013.12.011] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2013] [Revised: 10/16/2013] [Accepted: 12/07/2013] [Indexed: 02/01/2023] Open
Abstract
Hip instability after total hip replacement has been shown to be a critical cause of failure. The use of dual mobility has been classically restricted to patients "at risk", over 70 years of age. The question rises up about extended indications of so-called "modern" second generation dual mobility cups. This prospective multicenter study reports on first results at 2-5 years of the HA anatomical ADM cup upon two comparative groups of patients under 70 years (112 hips) vs. over 70 years of age (325 hips). No dislocation, migration, tilting, wear, or intra-prosthetic dislocation was recorded within each of the two cohorts. Survivorship for cup failures at this 4-year period was ideal at 100% in the younger patients, and 99.7% in the older group of patients.
Collapse
Affiliation(s)
- Jean-Alain Epinette
- Orthopaedic Research and Imaging Center in Arthroplasty Clinique Médico-Chirurgicale 200 rue d'Auvergne, Bruay-Labuissière, France
| | | | - Philippe Tracol
- Clinique Saint-Roch 235, route des Gordes, Cavaillon, France
| | - Gérard Pagazani
- Clinique du Docteur Montagard 23 boulevard Gambetta, Avignon, France
| | - Eric Vandenbussche
- Department of Orthopaedic Surgery, Hôpital Européen George Pompidou 20 rue Leblanc, Paris, France
| |
Collapse
|
19
|
Fabry C, Woernle C, Bader R. Self-centering dual-mobility total hip systems: Prediction of relative movements and realignment of different intermediate components. Proc Inst Mech Eng H 2014; 228:477-485. [PMID: 24718864 DOI: 10.1177/0954411914531116] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The increased jump distance against dislocation and the large range of motion due to the enlarged effective head diameter substantiate the use of dual-mobility systems in cases of total hip joint instability. For this type of total hip endoprostheses, an eccentric design of the outer bearing is assumed in order to provide a force-dependent self-centering mechanism and an improved joint stability against dislocation. The purpose of this study was to determine the relative movements and realignment of different intermediate components during various motion cycles as a result of the eccentric design. We established a validated mathematical model for eccentric dual-mobility systems, which allowed a comparison of relative movements, self-centering torque and overall frictional torque during four different activities in order to analyze their motion behavior in everyday life. In addition, the impact of different radial clearances on the dynamic performance of the self-centering mechanism was investigated. According to torque patterns and the validation experiment, the main articulation of eccentric dual-mobility systems was limited to the smaller inner bearing for the most daily life activities, i.e. the eccentric intermediate component remained in its current position and only with changing activity did the intermediate component realign clearly. However, an inappropriate dimensioning of the radial clearance could lead to a permanent realignment of the intermediate component during the motion cycles. In general, the self-centering mechanism of the intermediate component seems to have no negative influence on relative movements and wear propagation of dual-mobility cup systems if the clearance and eccentricity are appropriately dimensioned.
Collapse
Affiliation(s)
- Christian Fabry
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, University Medicine Rostock, Rostock, Germany
| | - Christoph Woernle
- Chair of Technical Dynamics, Faculty of Mechanical Engineering and Marine Technology, University Rostock, Rostock, Germany
| | - Rainer Bader
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, University Medicine Rostock, Rostock, Germany
| |
Collapse
|
20
|
Combes A, Migaud H, Girard J, Duhamel A, Fessy MH. Low rate of dislocation of dual-mobility cups in primary total hip arthroplasty. Clin Orthop Relat Res 2013; 471:3891-900. [PMID: 23516032 PMCID: PMC3825881 DOI: 10.1007/s11999-013-2929-3] [Citation(s) in RCA: 118] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Dual-mobility (DM) cups were introduced to minimize the risk of THA dislocation. The overall rate of dislocation of DM cups (including both large and small articulations) is controversial and ranges from 0% to 5% in previous studies. QUESTIONS/PURPOSES We therefore recorded (1) the dislocation rate, (2) loosening and osteolysis, and (3) subsequent related revisions with DM cups. METHODS Between 1998 and 2003, 2480 primary THAs with DM cups were undertaken in 2179 patients. The mean age was 69 years (range, 19-94 years). This group underwent specific clinical and radiographic evaluation at a minimum followup of 0.17 years (mean, 7 years; range, 0.17-11 years) to assess dislocation, reoperation, osteolysis, and cup fixation. RESULTS There were 22 dislocations (0.88%): 15 dislocations of large articulations (0.6%), with two (0.08%) recurring but only one requiring revision (0.04%), and seven intraprosthetic small articulation dislocations (0.28%), all needing revision surgery. At last followup, mean Harris hip score was 91 (range, 60-100); 2439 cups (98%) showed no signs of loosening; and 141 patients (145 hips) had osteolysis (6%). Osteolysis and cup loosening were more frequent in patients younger than 50 years at the time of surgery. The 10-year survivorship considering revision for any reason was 93% (95% CI, 91%-95%). CONCLUSIONS DM cups had a low dislocation rate in primary THA, with a limited frequency of adverse effects. We recommend DM cups to minimize dislocation in populations at high risk for instability, but they should be avoided in younger, active patients at higher risk for osteolysis.
Collapse
Affiliation(s)
- Antoine Combes
- />Roger Salengro Hospital, Centre Hospitalier Régional Universitaire de Lille, 2 Avenue, Oscar Lambret, 59037 Lille Cedex, France
| | - Henri Migaud
- />Roger Salengro Hospital, Centre Hospitalier Régional Universitaire de Lille, 2 Avenue, Oscar Lambret, 59037 Lille Cedex, France
| | - Julien Girard
- />Roger Salengro Hospital, Centre Hospitalier Régional Universitaire de Lille, 2 Avenue, Oscar Lambret, 59037 Lille Cedex, France
| | - Alain Duhamel
- />Centre d’Etudes et de Recherche en Informatique Médicale, Faculté Médecine, Université de Lille 2, Lille, France
| | - Michel Henri Fessy
- />Department of Orthopaedics, Traumatology and Sports Medicine, Centre Hospitalier Lyon Sud, Pierre Bénite, France
| |
Collapse
|
21
|
Mukka SS, Mahmood SS, Sjödén GO, Sayed-Noor AS. Dual mobility cups for preventing early hip arthroplasty dislocation in patients at risk: experience in a county hospital. Orthop Rev (Pavia) 2013; 5:48-51. [PMID: 23888200 PMCID: PMC3718234 DOI: 10.4081/or.2013.e10] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Revised: 04/19/2013] [Accepted: 04/21/2013] [Indexed: 11/25/2022] Open
Abstract
Dislocation remains a major concern after hip arthroplasty. We asked whether dual mobility cups (DMC) would improve early hip stability in patients with high risk of dislocation. We followed 34 patients (21 females, 13 males) treated between 2009 and 2012 with cemented DMC for hip revisions caused recurrent hip prosthetic dislocation or as a primary procedure in patients with high risk of instability. Functional outcome and quality of life were evaluated using Harris Hip Score and EQ-5D respectively. We found that the cemented DMC gave stability in 94%. Seven patients (20%) were re-operated due to infection. One patient sustained a periprosthetic fracture. At follow-up (6 to 36 months, mean 18), the mean Harris hip score was 67 (standard deviation: 14) and mean EQ-5D was 0.76 (standard deviation: 0.12). We concluded that treating patients with high risk of dislocation with DMC can give good stability. However, complications such as postoperative infection can be frequent and should be managed carefully.
Collapse
Affiliation(s)
- Sebastian S Mukka
- Department of Orthopaedics, Sundsvall Teaching Hospital; Department of Surgical and Perioperative Science, Umeå University , Sweden
| | | | | | | |
Collapse
|
22
|
Wegrzyn J, Thoreson AR, Guyen O, Lewallen DG, An KN. Cementation of a dual-mobility acetabular component into a well-fixed metal shell during revision total hip arthroplasty: a biomechanical validation. J Orthop Res 2013; 31:991-7. [PMID: 23335343 DOI: 10.1002/jor.22314] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2012] [Accepted: 12/20/2012] [Indexed: 02/04/2023]
Abstract
Cementation of polyethylene (PE) liners into well-fixed metal shells has become a popular option during revision total hip arthroplasty (THA) particularly for older and frail patients. Although dramatic results were reported with dual-mobility acetabular components to manage hip instability during revision THA, no study evaluated the fixation strength of the cementation of dual-mobility components into well-fixed metal shells. Eight dual-mobility and eight all-PE components were cemented into a metal shell with a uniform 2- to 3-mm cement mantle. The cemented fixation strength was evaluated using lever-out and torsion testing. The interface at which failure occurred was determined. Lever-out testing showed that dual-mobility components failed at significantly higher maximum moment than the all-PE components. No direct comparison could be performed with torsion testing due to early failure of the all-PE component itself before failure of the cement fixation. However, the maximum moments measured were dramatically higher than the in vivo frictional moments classically reported in THA. In addition, failure was always observed at the metal shell/cement interface whenever it did occur. In conclusion, a dual-mobility acetabular component cemented into a well-fixed metal shell could constitute a biomechanically acceptable alternative to acetabular shell removal or PE liner cementation while simultaneously preventing instability of the THA revision. Clinical studies are warranted.
Collapse
Affiliation(s)
- Julien Wegrzyn
- Biomechanics Laboratory, Mayo Clinic, Rochester, Minnesota, USA
| | | | | | | | | |
Collapse
|
23
|
Philippot R, Boyer B, Farizon F. Intraprosthetic dislocation: a specific complication of the dual-mobility system. Clin Orthop Relat Res 2013; 471:965-70. [PMID: 23054529 PMCID: PMC3563829 DOI: 10.1007/s11999-012-2639-2] [Citation(s) in RCA: 137] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2012] [Accepted: 09/26/2012] [Indexed: 01/31/2023]
Abstract
BACKGROUND The dual-mobility concept was proposed as an alternative to prevent postoperative dislocation events. However, intraprosthetic dislocation (IPD) is a troublesome and specific complication induced by the loss of the polyethylene retentive rim and escape of the femoral head from the polyethylene liner. The factors associated with IPD are unknown as only isolated cases have been reported and do not provide a clear understanding of the mechanisms of failure. QUESTIONS/PURPOSES We therefore (1) identified features related to different types of IPD and (2) determined factors related to the timing of IPD. METHODS We identified 81 cases (80 patients) with IPD from among 1960 primary THAs performed between January 1985 and December 1998. To classify the types of IPD we considered perioperative (presence of arthrofibrosis, cup loosening, and type of liner wear) and radiographic (radiographic cup loosening or migration, and ossification) features. RESULTS We identified three types of IPD with the following causal mechanisms: Type 1 was pure IPD without arthrofibrosis and without cup loosening (n = 26), Type 2 was IPD secondary to blocking of the liner (n = 41), and Type 3 was IPD associated with a cup loosening (n = 14). The mean times of onset were, 11, 8, and 9 years after THA, respectively. We found no difference according to the stem design regarding timing of the IPD. CONCLUSIONS This new IPD classification allows clinicians to anticipate the possible conditions they will encounter with revision surgery and plan surgery (cup removal, liner exchange, synovectomy). The implant characteristics and this new classification accounted for the differences in the timing of occurrence. LEVEL OF EVIDENCE Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Remi Philippot
- Department of Orthopaedic Surgery, University Hospital Center of Saint Etienne,
Saint Étienne Cedex 2, 42055 France
| | - Bertrand Boyer
- Department of Orthopaedic Surgery, University Hospital Center of Saint Etienne,
Saint Étienne Cedex 2, 42055 France ,Laboratoire de Physiologie de l’Exercice, EA 4338, Saint Étienne, France
| | - Frederic Farizon
- Department of Orthopaedic Surgery, University Hospital Center of Saint Etienne,
Saint Étienne Cedex 2, 42055 France ,Laboratoire de Physiologie de l’Exercice, EA 4338, Saint Étienne, France
| |
Collapse
|
24
|
Abstract
BACKGROUND Dislocation after THA continues to be relatively common. Dual mobility sockets have been associated with low dislocation rates, but it remains unclear whether their use in primary THA would not introduce additional complications. QUESTIONS/PURPOSES We therefore asked whether a current cementless dual mobility socket (1) reduced the dislocation rate after primary THA, (2) provided a pain-free and mobile hip, and (3) provided durable radiographic fixation of the acetabular component without any unique modes of failure. METHODS We retrospectively reviewed 168 patients who underwent primary THA using a dual mobility socket between January 2000 and June 2002. The average age at surgery was 67 years. We assessed the rate of dislocation, hip function, and acetabular fixation on serial radiographs. Of the 168 patients, 119 (71%) had clinical and radiographic evaluation at a minimum of 5 years (mean, 6 years; range, 5-8 years). RESULTS A long-neck option left the base of the Morse taper uncovered in 53 hips. Four patients underwent revision for dislocation between the femoral head and the mobile insert (intraprosthetic dislocation) at a mean 6 years; all four revisions occurred among the 53 hips with an incompletely covered Morse taper. CONCLUSIONS A current cementless dual mobility socket was associated with a pain-free and mobile hip and durable acetabular fixation without dislocations if the long-neck option was not used. However, intraprosthetic dislocation related to contact at the femoral neck to mobile insert articulation required revision in four hips. Surgeons should be aware of this specific complication. LEVEL OF EVIDENCE Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
25
|
Grazioli A, Ek ETH, Rüdiger HA. Biomechanical concept and clinical outcome of dual mobility cups. INTERNATIONAL ORTHOPAEDICS 2012; 36:2411-8. [PMID: 23073926 DOI: 10.1007/s00264-012-1678-3] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2012] [Accepted: 10/01/2012] [Indexed: 12/23/2022]
Abstract
Dual mobility cup systems in total hip arthroplasty consist of a metal back with a non-constrained liner, in which a constrained standard head articulates. While superior stability of such implants in comparison with standard total hip replacements is assumed, it is the purpose of this study to outline the biomechanical concept of dual mobility cups and to describe implant survival and dislocation rate based on the series published in the English-speaking and Francophone literature. A growing body of evidence indicates reduced dislocation rates in primary and revision total hip arthroplasty and in selected tumour cases. The limited availability of studies evaluating long-term implant survival and existing concerns with regard to increased wear rates and aseptic loosening, leads to the conclusion that such implants have to be used with prudence, particularly in standard primary hip arthroplasty and in young patients.
Collapse
Affiliation(s)
- Aron Grazioli
- Department of Orthopaedics and Traumatology, Centre Hospitalier Universitaire Vaudois CHUV, Av Pierre Decker 4, 1011, Lausanne, Switzerland
| | | | | |
Collapse
|
26
|
Stroh A, Naziri Q, Johnson AJ, Mont MA. Dual-mobility bearings: a review of the literature. Expert Rev Med Devices 2012; 9:23-31. [PMID: 22145838 DOI: 10.1586/erd.11.57] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Dislocation after total hip arthroplasty remains a major problem and hip instability is the most common reason for revision. These complications are costly to both patients and the healthcare system, and efforts to reduce them have had varied degrees of success. Although there are well documented patient and surgical risk factors for dislocation, the typical surgical solutions offered (constrained liners, large femoral heads) have the drawbacks of reduced range-of-motion and high rates of revision. Dual-mobility prostheses (unconstrained tripolar prostheses) are hip design solutions to dislocation that aim to provide a greater stability with an increased range-of-motion, along with potentially reduced wear. The mean overall dislocation rate from multiple combined studies using dual-mobility prostheses was 0.1% for primary total hip arthroplasty and 3.5% for revisions, compared with 2-7% for standard primary total hip arthroplasties and up to 16% for revisions. Dual-mobility prostheses offer a viable option for treating recurrent dislocation as well as for primary and revision arthroplasty.
Collapse
Affiliation(s)
- Alex Stroh
- Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, MD, USA
| | | | | | | |
Collapse
|
27
|
Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements. Clin Orthop Relat Res 2012; 470:1932-40. [PMID: 22161085 PMCID: PMC3369083 DOI: 10.1007/s11999-011-2213-3] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2011] [Accepted: 11/28/2011] [Indexed: 01/31/2023]
Abstract
BACKGROUND The use of dual-mobility cups has increased because of a low rate of dislocations combined with a 96% 15-year survival rate. However, late cup migrations have been attributed to their fixation (tripod - exact fit with two pegs and one extraacetabular screw) and the absence of porous coating. In a second-generation device, the designs were modified to achieve press-fit fixation and a layer of titanium beads was sintered on stainless steel cups. QUESTIONS/PURPOSES We therefore (1) determined the midterm survival of press-fit, grit-blasted, second-generation cups with or without additional screws, compared with original tripod and (2) compared survival of grit-blasted dual-mobility cups with bimetallic porous-coated cups. METHODS From a multiinstitutional trial, we reviewed 2408 patients with osteoarthritis implanted with 2601 prostheses of seven designs of a second-generation dual-mobility cup. The criteria for failure were migration, widening radiolucencies in any zone of the interface, or revision for cup loosening. The minimum followup was 5 years (mean, 7.7 years; range, 5-11 years). RESULTS The 8-year survival rate of press-fit, grit-blasted cups was lower than that for press-fit, grit-blasted cups fixed with screws (91% versus 100%) and for tripod fixation (98%). The 8-year survival rate of press-fit, grit-blasted cups was less than that for press-fit, porous-coated cups made of the same alloy (91% versus 95%). CONCLUSIONS The data suggested primary fixation of grit-blasted dual-mobility cups should be secured with screws. Porous coating sintered on the convex side improved midterm survivorship. No deleterious effect of metallosis resulted from sintered titanium beads on stainless steel. Long-term followup is required to confirm these findings.
Collapse
|
28
|
Vasukutty NL, Middleton RG, Matthews EC, Young PS, Uzoigwe CE, Minhas THA. The double-mobility acetabular component in revision total hip replacement. ACTA ACUST UNITED AC 2012; 94:603-8. [DOI: 10.1302/0301-620x.94b5.27876] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
We present our experience with a double-mobility acetabular component in 155 consecutive revision total hip replacements in 149 patients undertaken between 2005 and 2009, with particular emphasis on the incidence of further dislocation. The mean age of the patients was 77 years (42 to 89) with 59 males and 90 females. In all, five patients died and seven were lost to follow-up. Indications for revision were aseptic loosening in 113 hips, recurrent instability in 29, peri-prosthetic fracture in 11 and sepsis in two. The mean follow-up was 42 months (18 to 68). Three hips (2%) in three patients dislocated within six weeks of surgery; one of these dislocated again after one year. All three were managed successfully with closed reduction. Two of the three dislocations occurred in patients who had undergone revision for recurrent dislocation. All three were found at revision to have abductor deficiency. There were no dislocations in those revised for either aseptic loosening or sepsis. These results demonstrate a good mid-term outcome for this component. In the 29 patients revised for instability, only two had a further dislocation, both of which were managed by closed reduction.
Collapse
Affiliation(s)
- N. L. Vasukutty
- Pilgrim Hospital, Department
of Trauma and Orthopaedics, Sibsey Road, Boston, Lincolnshire
PE21 9QS, UK
| | - R. G. Middleton
- Cheltenham General Hospital, Department
of Trauma and Orthopaedics, Sandford Road, Cheltenham, Gloucestershire
GL53 7AN, UK
| | - E. C. Matthews
- Pilgrim Hospital, Department
of Trauma and Orthopaedics, Sibsey Road, Boston, Lincolnshire
PE21 9QS, UK
| | - P. S. Young
- Southern General Hospital, Department
of Orthopaedics, 1345 Govan Road, Glasgow G51
4TF, UK
| | - C. E. Uzoigwe
- Leicester Royal Infirmary, Department
of Orthopaedics, Infirmary Square, Leicester LE1
5WW, UK
| | - T. H. A. Minhas
- Pilgrim Hospital, Department
of Trauma and Orthopaedics, Sibsey Road, Boston, Lincolnshire
PE21 9QS, UK
| |
Collapse
|
29
|
Abstract
Total hip arthroplasty (THA) is an effective intervention for the treatment of arthrosis with excellent survivorship. Nonetheless, dislocation and osteolysis remain significant complications. A dual-mobility acetabular component has been advocated to improve stability and wear. Stability is imparted by increasing the effective femoral head size, which allows a larger range of motion (ROM) before neck-socket impingement occurs. Increasing ROM, however, introduces an additional problem of bony impingement of the trochanter against the pelvis. Consequently, there is little improvement in ROM for heads >36 to 40 mm. A 0.4% incidence of instability at the larger articulation has been reported in primary THA using the dual-mobility liner, which is equivalent to reports for conventional THA. The dual-mobility liner has introduced the unique complication of intraprosthetic dislocation, where the femoral head dissociates at the smaller articulation as a result of polyethylene wear. An incidence of intraprosthetic dislocation of 3.6% has been reported, which far exceeds dislocation of conventional arthroplasty. The dual-mobility liner is a monoblock acetabular component without the capacity for augmented bony fixation. Inability to achieve primary stability has been reported as high as 18% and therefore its usefulness in revision THA is questionable. Proponents of the dual-mobility liner cite improved wear characteristics over conventional THA; however, few studies support this proposition. Retrieval studies have reported that the dual-mobility liner does not avoid wear or osteolysis. Theoretically, it is inconceivable that wear would be diminished with an additional articulation with a huge surface area, where the differential hardness has been reversed to a soft-on-hard bearing.
Collapse
Affiliation(s)
- Matthew C Lyons
- Division of Orthopedic Surgery, University of Western Ontario & London Health Sciences Centre, London, Ontario, Canada
| | | |
Collapse
|
30
|
Vielpeau C, Lebel B, Ardouin L, Burdin G, Lautridou C. The dual mobility socket concept: experience with 668 cases. INTERNATIONAL ORTHOPAEDICS 2010; 35:225-30. [PMID: 21184223 DOI: 10.1007/s00264-010-1156-8] [Citation(s) in RCA: 126] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2010] [Revised: 10/25/2010] [Accepted: 10/26/2010] [Indexed: 12/24/2022]
Abstract
Long-term results of a retrospective series of primary arthroplasty with the original cementless dual mobility socket (A) and the midterm results with the second generation (B) are reported. In series A (follow-up 16.5 years) 437 total hip arthroplasties (THA) were included and in series B (follow-up five years) 231 hips. The 15-year survival rate was 84.4 ± 4.5% (revision for any reason as endpoint); 30 hips (6.8%) were revised for aseptic loosening. Five THA were revised for dislocation: two early and three after ten years or more. With the second generation socket neither dislocation nor revision for mechanical reasons were observed. The survival rate was 99.6 ± 0.4% (revision for any reason). The prevalence of revision for dislocation was very low in our series. This concept does not avoid wear and aseptic loosening, especially in young active patients, but the long-term stability has been confirmed. Dual mobility can be recommended for patients over 70 years of age and for younger patients with high risk of dislocation.
Collapse
|
31
|
Hamadouche M, Biau DJ, Huten D, Musset T, Gaucher F. The use of a cemented dual mobility socket to treat recurrent dislocation. Clin Orthop Relat Res 2010; 468:3248-54. [PMID: 20532718 PMCID: PMC2974879 DOI: 10.1007/s11999-010-1404-7] [Citation(s) in RCA: 99] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The treatment of recurrent dislocation after total hip arthroplasty remains challenging. Dual mobility sockets have been associated with a low rate of dislocation but it is not known whether they are useful for treating recurrent dislocation. QUESTIONS/PURPOSES We therefore asked whether a cemented dual mobility socket would (1) restore hip stability following recurrent dislocation; (2) provide a pain-free and mobile hip; and (3) show durable radiographic fixation. METHODS We retrospectively reviewed 51 patients treated with a cemented dual mobility socket for recurrent dislocation after total hip arthroplasty between August 2002 and June 2005. The mean age at the time of the index procedure of was 71.3 years. Of the 51 patients, 47 have had complete clinical and radiographic evaluation data at a mean followup of 51.4 months (range, 25-76.3 months). RESULTS The cemented dual mobility socket restored complete stability of the hip in 45 of the 47 patients (96%). The mean Merle d'Aubigné hip score was 16 ± 2 at the latest followup. Radiographic analysis revealed no or radiolucent lines less than 1 mm thick located in a single acetabular zone in 43 of 47 hips (91.5%). The cumulative survival rate of the acetabular component at 72 months using revision for dislocation and/or mechanical failure as the end point was 96% ± 4% (95% confidence interval, 90%-100%). CONCLUSIONS A cemented dual mobility socket was able to restore hip stability in 96% of recurrent dislocating hips. However, longer-term followup is needed to ensure that dislocation and loosening rates will not increase.
Collapse
Affiliation(s)
- Moussa Hamadouche
- The Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Service A, Centre Hospitalo-Universitaire Cochin-Port Royal, Université René Descartes, Hôpital Cochin (AP-HP), 75014, Paris, France.
| | | | | | | | | |
Collapse
|
32
|
Use of a dual mobility socket to manage total hip arthroplasty instability. Clin Orthop Relat Res 2009; 467:465-72. [PMID: 18780135 PMCID: PMC2628522 DOI: 10.1007/s11999-008-0476-0] [Citation(s) in RCA: 139] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2007] [Accepted: 08/08/2008] [Indexed: 01/31/2023]
Abstract
UNLABELLED Unconstrained tripolar hip implants provide an additional bearing using a mobile polyethylene component between the prosthetic head and the outer metal shell. Such a design increases the effective head diameter and therefore is an attractive option in challenging situations of unstable total hip arthroplasties. We report our experience with 54 patients treated using this dual mobility implant in such situations. We ascertained its ability to restore and maintain stability, and examined component loosening and component failure. At a minimum followup of 2.2 years (mean, 4 years; range, 2.2-6.8 years), one hip had redislocated 2 months postoperatively and was managed successfully without reoperation by closed reduction with no additional dislocation. Two patients required revision of the implant because of dislocation at the inner bearing. Technical errors were responsible for these failures. Three patients had reoperations for deep infections. The postoperative radiographs at latest followup showed very satisfactory osseointegration of the acetabular component because no radiolucent line or osteolysis was reported. Use of this unconstrained tripolar design was successful in restoring and maintaining hip stability. We observed encouraging results at short-term followup regarding potential for loosening or mechanical failures. LEVEL OF EVIDENCE Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
|
33
|
The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. INTERNATIONAL ORTHOPAEDICS 2008; 33:927-32. [PMID: 18521598 DOI: 10.1007/s00264-008-0589-9] [Citation(s) in RCA: 155] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2008] [Revised: 04/07/2008] [Accepted: 04/08/2008] [Indexed: 01/30/2023]
Abstract
The concept of a dual articulation acetabular cup was developed by Prof. Bousquet in 1974. This concept has been shown to provide high stability after revision and primary total hip arthroplasty. The aim of our study was to evaluate the incidence of prosthetic instability in a consecutive homogeneous series of 384 primary dual mobility cups. Incidence of instability and implant survival were evaluated. Mean follow-up was 15.3 years (range, 12-20). There was no early or late instability. On the acetabular side there were 13 aseptic loosenings, 14 intraprosthetic dislocations, and seven polyethylene wear cases that required replacement of the liner. The cumulative survival rate of the dual-articulation acetabular cup using surgical revision for aseptic loosening as the endpoint was 95.9% +/- 4.1% at 18 years postoperatively. Our series proves the good long term behaviour of dual-articulation acetabular components in primary arthroplasty. Their excellent survivorship rate and the absence of episodes of prosthetic instability increase our confidence in this concept.
Collapse
|
34
|
Langlais FL, Ropars M, Gaucher F, Musset T, Chaix O. Dual mobility cemented cups have low dislocation rates in THA revisions. Clin Orthop Relat Res 2008; 466:389-95. [PMID: 18196422 PMCID: PMC2505133 DOI: 10.1007/s11999-007-0047-9] [Citation(s) in RCA: 136] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2007] [Accepted: 11/01/2007] [Indexed: 01/31/2023]
Abstract
UNLABELLED THA revisions using standard cups are at risk of dislocation (5.1% to 14.4% incidence), especially in patients over 70 years of age. Constrained tripolar cups have reduced this risk (6% incidence) but are associated with substantial loosening rates (9%). The nonconstrained dual mobility cup was designed to improve prosthetic stability (polyethylene head >or= 40 mm diameter) without increasing loosening rates by reducing wear and limiting impingement (rotation range of 108 degrees). We implanted 88 cemented dual mobility cups for THA revisions in 82 patients at high risk of dislocation. Average patient age was 72 years (range, 65-86 years). Eighty-five of the 88 hips were reviewed at 2 to 5 years followup. One patient (1.1%) had a traumatic dislocation at 2 years postoperatively. Two patients (2.3%) had asymptomatic early loosening and three patients (3.5%) had localized radiographic lucencies. These results confirm those with press-fit dual mobility cups suggesting a low dislocation rate at 5 years and a cup survival of 94.6%. At middle term followup, cemented dual mobility cup achieved better results than constrained cups in cases at risk of dislocation and recurrent loosening. LEVEL OF EVIDENCE Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
| | - Mickaël Ropars
- University Hospital, 16 boulevard de Bulgarie, 35203 Rennes, France
| | - François Gaucher
- University Hospital, 16 boulevard de Bulgarie, 35203 Rennes, France
| | - Thierry Musset
- University Hospital, 16 boulevard de Bulgarie, 35203 Rennes, France
| | - Olivier Chaix
- University Hospital, 16 boulevard de Bulgarie, 35203 Rennes, France
| |
Collapse
|