1
|
Rawala MS, Badami V, Rizvi SB, Nanjundappa A. Aortoesophageal Fistula: A Fatal Complication of Thoracic Endovascular Aortic Stent-Graft Placement. AMERICAN JOURNAL OF CASE REPORTS 2018; 19:1258-1261. [PMID: 30348937 PMCID: PMC6206620 DOI: 10.12659/ajcr.911441] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Patient: Female, 80 Final Diagnosis: Aortoesophageal fistula Symptoms: Hematemesis Medication: — Clinical Procedure: Thoracic endovascular aortic repair Specialty: General and Internal Medicine
Collapse
Affiliation(s)
- Muhammad Shabbir Rawala
- Department of Internal Medicine, West Virginia University (WVU) - Charleston Division, Charleston, WV, USA
| | - Varun Badami
- Department of Internal Medicine, West Virginia University (WVU) - Morgantown Division, Morgantown, WV, USA
| | - Syed Bilal Rizvi
- Department of Cardiology, Rapides Regional Medical Center, Alexandria, LA, USA
| | - Aravinda Nanjundappa
- Department of Cardiology and Vascular Surgery, West Virginia University (WVU) - Charleston Division, Charleston, WV, USA
| |
Collapse
|
2
|
Thompson CS, Rodriguez JA, Ramaiah VG, Olsen D, Diethrich EB. Pseudoaneurysm of the Aortic Arch After Aortosubclavian Bypass Treated with Endoluminal Stent Grafting. Vasc Endovascular Surg 2016; 37:375-9. [PMID: 14528385 DOI: 10.1177/153857440303700511] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This paper describes a case of aortic arch pseudoaneurysm treated with stent graft 2 years after aortosubclavian bypass repair of a subclavian artery aneurysm. An 84-year-old man presented with back pain. Two years before, he had had a left subclavian artery aneurysm repaired with aortosubclavian bypass. Upon examination by computed tomography (CT) scan and angiography he was found to have a bovine arch configuration, a 7-centimeter pseudoaneurysm arising from the stump of the native subclavian artery, a patent aortosubclavian bypass, and a left hemothorax. A 37 mm by 10 mm Gore Excluder thoracic graft was introduced into the right femoral artery cutdown and deployed across the arch, excluding the pseudoaneurysm and preserving the brachiocephalic vessels. Follow up CT scan at 1 year shows exclusion of the pseudoaneurysm. The patient continues to do well 1 year after implantation without evidence of endoleak. In the presence of unusual anatomical characteristics, endoluminal stent graft repair can be successfully performed across the aortic arch.
Collapse
Affiliation(s)
- Charles S Thompson
- Department of Vascular Surgery, Orlando Regional Medical Center, Orlando, FL, USA
| | | | | | | | | |
Collapse
|
3
|
Haji Zeinali AM, Marzban M, Zafarghandi M, Shirzad M, Shirani S, Mahmoodian R, Sheikhvatan M, Lotfi-Tokaldany M. Endovascular Aortic Aneurysm and Dissection Repair (EVAR) in Iran: Descriptive Midterm Follow-up Results. IRANIAN JOURNAL OF RADIOLOGY 2016; 13:e16021. [PMID: 27110330 PMCID: PMC4836048 DOI: 10.5812/iranjradiol.16021] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2013] [Revised: 07/12/2014] [Accepted: 08/25/2014] [Indexed: 11/16/2022]
Abstract
Background: Endovascular repair of aorta in comparison to open surgery has a low early operative mortality rate, but its long-term results are uncertain. Objectives: The current study describes for the first time our initial four-year experience of elective endovascular aortic repair (EVAR) at Tehran heart center, the first and a major referral heart center in Iran, as a pioneer of EVAR in Iran. Patients and Methods: A total of 51 patients (46 men) who had the diagnosis of either an abdominal aortic aneurysm (AAA) (n = 36), thoracic aortic aneurysm (TAA) (n = 7), or thoracic aortic dissection (TAD) (n = 8) who had undergone EVAR by Medtronic stent grafts by our team between December 2006 and June 2009 were reviewed. Results: The rate of in-hospital aneurysm-related deaths in the group with AAA stood at 2.8% (one case), while there was no in-hospital mortality in the other groups. All patients were followed up for 13-18 months. The cumulative death rate in follow-up was nine cases from the total 51 cases (18%), out of which six cases were in the AAA group (four patients due to non-cardiac causes and two patients due to aneurysm-related causes), one case in the TAA group (following a severe hemoptysis), and two cases in the TAD group (following an expansion of dissection from re-entrance). The major event-free survival rate was 80.7% for endovascular repair of AAA, 85.7% for endovascular repair of TAA, and 65.6% for endovascular repair of TAD. Conclusion: The endovascular stent-graft repair of the abdominal and thoracic aortic aneurysm and aortic dissection had high technical success rates in tandem with low-rate early mortality and morbidity, short hospital stay, and acceptable mid-term free symptom survival among Iranian patients.
Collapse
Affiliation(s)
- Ali Mohammad Haji Zeinali
- Department of Interventional Cardiology, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
- Corresponding author: Ali Mohammad Haji Zeinali, Department of Interventional Cardiology, Tehran Heart Center, Tehran University of Medical Sciences, P. O. Box: 1411713138, Tehran, Iran. Tel: +98-218802960060, Fax: +98-2188029731, E-mail:
| | - Mehrab Marzban
- Department of Cardiac Surgery, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammadreza Zafarghandi
- Department of Vascular Surgery, Sina Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Mahmood Shirzad
- Department of Cardiac Surgery, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Shapour Shirani
- Department of Radiology, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Roshanak Mahmoodian
- Department of Research, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Mehrdad Sheikhvatan
- Department of Research, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Masoumeh Lotfi-Tokaldany
- Department of Research, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Lee M, Lee DY, Kim MD, Won JY, Yune YN, Lee TY, Choi D, Ko YG. Selective coverage of the left subclavian artery without revascularization in patients with bilateral patent vertebrobasilar junctions during thoracic endovascular aortic repair. J Vasc Surg 2013; 57:1311-6. [DOI: 10.1016/j.jvs.2012.10.110] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2012] [Revised: 10/24/2012] [Accepted: 10/25/2012] [Indexed: 10/27/2022]
|
5
|
|
6
|
Rousseau H, Cosin O, Marcheix B, Chabbert V, Midulla M, Dambrin C, Cron C, Leobon B, Conil C, Massabuau P, Otal P, Joffre F. Endovascular treatment of thoracic dissection. Semin Intervent Radiol 2011; 24:167-79. [PMID: 21326794 DOI: 10.1055/s-2007-980041] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Type A aortic dissection remains fatal if untreated. Although classical medical therapy for type B dissection is considered the therapy of choice in uncomplicated cases, the paradigm is changing as greater experience is accrued with endovascular treatments and technical advances improve the long-term outlook. Diagnosis is also becoming more sophisticated, allowing greater appreciation of the anatomy of dissections and improving the knowledge base as their natural history is assessed.
Collapse
Affiliation(s)
- H Rousseau
- Department of Radiology, Cardio-Vascular Surgery and Cardiology, Hôpital Rangueil, Toulouse, France
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Hornez E, Bourgouin S, Baudoin Y, Prunet B, Monchal T, Schlienger G, Meyrat L, Thouard H. [Management of seat-belt aorta in severe polytrauma: a review]. JOURNAL DES MALADIES VASCULAIRES 2011; 36:237-242. [PMID: 21684701 DOI: 10.1016/j.jmv.2011.05.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2010] [Accepted: 05/05/2011] [Indexed: 05/30/2023]
Abstract
Blunt trauma of the abdominal aorta is rare. Secondary to high-energy trauma, it is observed mainly in association with complex lesions. Evaluation of injury to the aorta must be a priority due to the risk of life-threatening massive hemorrhage. The clinical presentation can be quite obvious but also variable and often misleading. If in doubt, a systematic injected whole body scan is essential to diagnose aortic lesions. Hemorrhage or ischemia dictates emergency laparotomy. Opening the retroperitoneum increases the risk of infection if there is an associated gastrointestinal tract injury and may contraindicate use of arterial prostheses. Endovascular treatment can be proposed for less symptomatic lesions, including intimal dissection. Stents can be inserted via a femoral approach. In the event of juxtarenal dissection, there is a risk of renal artery thrombosis. Endovascular treatment is currently not recommended. This treatment can be delayed for a few days if necessary. Morbidity is low and long-term results are good.
Collapse
Affiliation(s)
- E Hornez
- Service de chirurgie digestive et vasculaire, département d'anesthésie réanimation, hôpital d'Instruction des Armées, boulevard Sainte-Anne, Toulon, France.
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Weigang E, Parker JA, Czerny M, Lonn L, Bonser RS, Carrel TP, Mestres CA, Di Bartolomeo R, Schepens MA, Bachet JE, Vahl CF, Grabenwoger M. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation? Eur J Cardiothorac Surg 2011; 40:858-68. [DOI: 10.1016/j.ejcts.2011.01.046] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2010] [Revised: 01/18/2011] [Accepted: 01/20/2011] [Indexed: 11/16/2022] Open
|
9
|
Akın I, Kische S, Schneider H, Ince H, Nienaber C. Das thorakale Aortenaneurysma. Internist (Berl) 2009; 50:964-71. [DOI: 10.1007/s00108-009-2361-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
10
|
Lin PH, Huynh TT, Kougias P, Huh J, LeMaire SA, Coselli JS. Descending Thoracic Aortic Dissection: Evaluation and Management in the Era of Endovascular Technology. Vasc Endovascular Surg 2008; 43:5-24. [DOI: 10.1177/1538574408318475] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Acute aortic dissection is a relatively uncommon but highly lethal condition. Without proper treatment, devastating consequences can occur due to aortic rupture, cardiac tamponade, or irreversible ischemia involving the spinal cord or the visceral organs. The treatment strategy of this condition is in part influenced by the location and the severity of aortic dissection as immediate surgical intervention is necessary in acute ascending aortic dissection, whereas medical therapy is the initial treatment approach in uncomplicated descending aortic dissection. Recent advances of endovascular technology have broadened the potential application of this catheter-based therapy in aortic pathologies, including descending thoracic aortic dissection. In this article, the etiology, pathogenesis, and classification of this condition are discussed. The diagnostic benefits of various imaging modalities for descending aortic dissection are also discussed. Current treatment strategies, including medical, surgical, and catheter-based interventions, are reviewed. Lastly, clinical experiences of endovascular treatment for descending aortic dissection and various endovascular devices potentially applicable for this condition are discussed.
Collapse
Affiliation(s)
- Peter H. Lin
- Michael E. DeBakey Department of Surgery, Division of Vascular Surgery and Endovascular Therapy, Baylor College of Medicine, and Michael E. DeBakey VA Medical Center,
| | - Tam T. Huynh
- Michael E. DeBakey Department of Surgery, Division of Vascular Surgery and Endovascular Therapy, Baylor College of Medicine, and Michael E. DeBakey VA Medical Center
| | - Panagiotis Kougias
- Michael E. DeBakey Department of Surgery, Division of Vascular Surgery and Endovascular Therapy, Baylor College of Medicine, and Michael E. DeBakey VA Medical Center
| | - Joseph Huh
- Michael E. DeBakey Department of Surgery, Division of Cardiothoracic Surgery, Baylor College of Medicine, and Texas Heart Institute at St. Luke's Episcopal Hospital Houston, Texas
| | - Scott A. LeMaire
- Michael E. DeBakey Department of Surgery, Division of Cardiothoracic Surgery, Baylor College of Medicine, and Texas Heart Institute at St. Luke's Episcopal Hospital Houston, Texas
| | - Joseph S. Coselli
- Michael E. DeBakey Department of Surgery, Division of Cardiothoracic Surgery, Baylor College of Medicine, and Texas Heart Institute at St. Luke's Episcopal Hospital Houston, Texas
| |
Collapse
|
11
|
Wang S, Chang G, Li X, Hu Z, Li S, Yang J, Chen W, Li J. Endovascular treatment of arch and proximal thoracic aortic lesions. J Vasc Surg 2008; 48:64-8. [DOI: 10.1016/j.jvs.2008.02.010] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2007] [Revised: 02/08/2008] [Accepted: 02/08/2008] [Indexed: 11/16/2022]
|
12
|
Moon MC, Dowdall JF, Roselli EE. The use of right ventricular pacing to facilitate stent graft deployment in the distal aortic arch: A case report. J Vasc Surg 2008; 47:629-31. [DOI: 10.1016/j.jvs.2007.08.055] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2007] [Revised: 08/15/2007] [Accepted: 08/17/2007] [Indexed: 12/01/2022]
|
13
|
Piscione F, Sarno G, Iannelli G, Di Tommaso L, Furbatto F, D'Andrea C, Accardo D, Chiariello M. Acute aortic syndromes at high surgical risk: the endovascular approach. EUROINTERVENTION 2008; 3:499-505. [DOI: 10.4244/eijv3i4a88] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
14
|
Daniel JC, Huynh TT, Zhou W, Kougias P, El Sayed HF, Huh J, Coselli JS, Lin PH, LeMaire SA. Acute aortic dissection associated with use of cocaine. J Vasc Surg 2007; 46:427-33. [PMID: 17826227 DOI: 10.1016/j.jvs.2007.05.040] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2007] [Accepted: 05/15/2007] [Indexed: 11/29/2022]
Abstract
PURPOSE Cocaine use can result in a variety of cardiovascular complications, including myocardial infarction, arterial thrombosis, coronary dissection, and cardiomyopathy. Cocaine-induced aortic dissection is uncommon and has been described largely in case reports. The purpose of this study was to review our experience with aortic dissection associated with cocaine abuse. METHODS A retrospective chart review was performed of all hospital records during a 15-year period in patients diagnosed with aortic dissection. Among the 164 cases of acute aortic dissection, 16 patients (9.8%) had used cocaine or its derivative, crack cocaine, within 24 hours prior to the onset of symptoms. The remaining 148 patients (90.2%) had no history of cocaine usage. Clinical features, management, and outcome in these two groups were compared. RESULTS In the cocaine group, powder cocaine was inhaled intranasally in 11 patients (69%) and crack cocaine was smoked in five cases (31%). The mean duration between cocaine use and the onset of aortic dissection was 12.8 hours (range, 4 to 24 hours). Patients in the cocaine group were younger in age and more likely to have a history of polysubstance abuse than the non-cocaine cohort. In the cocaine group, the incidence of DeBakey dissection type I, II, IIIa, and IIIb was 19%, 25%, 38%, and 19%, respectively. In the group without cocaine use, the incidence of DeBakey dissection type I, II, IIIa, and IIIb was 18%, 23%, 39%, and 20%, respectively. Surgical intervention for aortic dissection was performed in 50% of the cocaine group and 45% of the non-cocaine group. In patients who underwent surgical repair, greater pulmonary complications occurred in the cocaine group than the non-cocaine group (n = 0.02). No difference was noted in the hospital length of stay or 30-day operative mortality among the two groups. CONCLUSIONS Cocaine-associated aortic dissection occurs in predominantly male patients with illicit drug abuse who were younger than patients with aortic dissection without cocaine use. Greater pulmonary complications can occur in patients with cocaine-related aortic dissection following surgical interventions.
Collapse
Affiliation(s)
- Jonathan C Daniel
- Division of Vascular Surgery and Endovascular Therapy, Michael E. DeBakey Department of Surgery, Baylor College of Medicine, and the Michael E. DeBakey VA Medical Center, Houston, TX 77030, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Zierer A, Melby SJ, Lubahn JG, Sicard GA, Damiano RJ, Moon MR. Elective Surgery for Thoracic Aortic Aneurysms: Late Functional Status and Quality of Life. Ann Thorac Surg 2006; 82:573-8. [PMID: 16863767 DOI: 10.1016/j.athoracsur.2006.03.042] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2006] [Revised: 03/08/2006] [Accepted: 03/14/2006] [Indexed: 11/16/2022]
Abstract
BACKGROUND Elective surgical treatment for thoracic aortic aneurysms is unique in that it is often performed on asymptomatic patients. Although it has been found to improve survival, the impact of elective surgery on late functional status and quality of life have yet to be examined. METHODS Over a 5-year period, 110 asymptomatic patients underwent elective thoracic aortic replacement for ascending, descending, or thoracoabdominal aneurysms. Mean age was 67 +/- 9 years (53 > or = 70 years). Functional status, physical and psychological quality of life (Medical Outcome Study 36-Item Short Form Health Survey, in which 50 represents normalized age-matched US population), and survival (Kaplan-Meier) were assessed. RESULTS Return to normal activity level was independent of age (p > 0.59) and procedure (p > 0.18). At 35 +/- 20 months, psychological quality of life was similar between surgical groups (p > 0.71), but physical quality of life was lower after thoracoabdominal versus ascending or descending aneurysms (p < 0.02). Age did not impact physical quality of life (40 +/- 13 > or = 70 years versus 42 +/- 11 < 70 years, p > 0.58), but older patients had improved psychological quality of life (52 +/- 9 > or = 70 years versus 47 +/- 8 < 70 years, p > 0.03). Overall survival was 79% +/- 4% at 2 years and 70% +/- 5% at 4 years, but was lower with thoracoabdominal versus ascending or descending aneurysms (p < 0.002). Multivariate analysis identified thoracoabdominal (p < 0.004), advanced age (p < 0.03), chronic renal failure (p < 0.03), and congestive heart failure (p < 0.001) as predictors of late death. CONCLUSIONS Advanced age did not impair return to normal functional status, and older patients had improved psychological quality of life. Survival and physical quality of life were lowest with thoracoabdominal versus ascending or descending aneurysms. Thus, patients with asymptomatic thoracic aneurysms should not be denied elective replacement based on age alone, as functional recovery was not significantly impaired.
Collapse
Affiliation(s)
- Andreas Zierer
- Division of Cardiothoracic Surgery, Washington University School of Medicine, St. Louis, Missouri 63110-1013, USA
| | | | | | | | | | | |
Collapse
|
16
|
Carr JA. The results of catheter-based therapy compared with surgical repair of adult aortic coarctation. J Am Coll Cardiol 2006; 47:1101-7. [PMID: 16545637 DOI: 10.1016/j.jacc.2005.10.063] [Citation(s) in RCA: 102] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2005] [Revised: 10/02/2005] [Accepted: 10/12/2005] [Indexed: 02/07/2023]
Abstract
A review was performed to compare the results of endovascular therapy (stenting and angioplasty) with surgical techniques to repair adult aortic coarctation. The immediate improvement in hypertension and the morbidity were similar across all groups. Surgical therapy was associated with a very low risk of restenosis and recurrence, whereas endovascular therapy had a much higher incidence of restenosis and the need for repeat interventions. The long-term outcome of endovascular approaches will need to be assessed in the future.
Collapse
Affiliation(s)
- John Alfred Carr
- Department of Cardiovascular and Thoracic Surgery, University of Chicago, Chicago, Illinois 60637, USA.
| |
Collapse
|
17
|
Kwolek CJ, Fairman R. Update on Thoracic Aortic Endovascular Grafting Using the Medtronic Talent Device. Semin Vasc Surg 2006; 19:25-31. [PMID: 16533689 DOI: 10.1053/j.semvascsurg.2005.11.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This article provides a brief update on the current status of the treatment of thoracic aortic pathology using the Medtronic Talent device. Preoperative evaluation and selection criterion along with study design are described for the recently completed Phase II VALOR Trial (Evaluation of the Medtronic AVE Talent Thoracic Stent Graft System for the Treatment of Thoracic Aneurysms). In addition, the results of several recent series for the treatment of degenerative aneurysm and more complex aortic pathology such as transection, rupture and acute and chronic dissection are reviewed.
Collapse
Affiliation(s)
- Christopher J Kwolek
- Department of Surgery, Division of Vascular and Endovascular Surgery, Harvard Medical School, Massachusetts General Hospital, Boston, MA 02114, USA.
| | | |
Collapse
|
18
|
Garzón G, Fernández-Velilla M, Martí M, Acitores I, Ybáñez F, Riera L. Endovascular Stent-Graft Treatment of Thoracic Aortic Disease. Radiographics 2005; 25 Suppl 1:S229-44. [PMID: 16227493 DOI: 10.1148/rg.25si055513] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Aneurysmal diseases of the thoracic aorta are life-threatening conditions. In such cases, stent-graft treatment has been proposed as an alternative to surgery. The morbidity and mortality associated with endovascular repair are significantly lower than those associated with open surgery. In the largest surgical series, the mortality ranged from 5% to 20%. In studies of endovascular repair, the 30-day mortality was 0%-20% and the periprocedural stroke rate was 0%-7%. Often, open surgery is prohibited in patients with these high-risk lesions; thus, in many cases endovascular treatment is the only alternative. Thoracic aortic diseases that can be treated with endovascular stent-graft placement include aneurysms, dissection, traumatic rupture, traumatic pseudoaneurysms, intramural hematoma, penetrating atherosclerotic ulcers, and aortic rupture. Thorough preprocedure imaging is essential for selecting patients, choosing the stent-graft devices, and planning the intervention. Prerequisites for endovascular stent-graft placement are an adequate neck for graft attachment and adequate vascular access. When the ascending aorta or aortic arch is involved, surgical and endovascular procedures can be combined and performed simultaneously, allowing treatment of a wider range of cases. An experienced interdisciplinary team is needed to manage such cases.
Collapse
Affiliation(s)
- Gonzalo Garzón
- Department of Radiology, Hospital Universitario La Paz, Paseo de la Castellana 261, 28046 Madrid, Spain
| | | | | | | | | | | |
Collapse
|
19
|
Criado FJ, Abul-Khoudoud OR, Domer GS, McKendrick C, Zuzga M, Clark NS, Monaghan K, Barnatan MF. Endovascular Repair of the Thoracic Aorta: Lessons Learned. Ann Thorac Surg 2005; 80:857-63; discussion 863. [PMID: 16122443 DOI: 10.1016/j.athoracsur.2005.03.110] [Citation(s) in RCA: 110] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2004] [Revised: 03/06/2005] [Accepted: 03/16/2005] [Indexed: 11/15/2022]
Abstract
BACKGROUND Available information on outcome and best strategies for thoracic endovascular repair is somewhat limited and unclear. We sought to gain a better understanding of these issues through a retrospective review of our 8-year clinical experience in the treatment of thoracic aortic aneurysms and dissections. METHODS A retrospective chart review of 186 patients undergoing stent-graft repair of thoracic aortic lesions at our institution during the 92-month period ending on December 31, 2004 was performed. Patients were divided into two groups based on the indication for treatment; group A had thoracic aortic aneurysms (TAA) and group B had type B aortic dissections (TBAD). Both groups were analyzed for outcome variables including technical success, mortality, major morbidity, endoleak rate and type, secondary endovascular interventions, and long-term survival. Mean follow-up was 40 months (range, 1 to 92 months). RESULTS Compared to group B, group A patients were older and had a higher incidence of peripheral vascular disease and chronic obstructive pulmonary disease. Sixty percent of all patients were American Society of Anesthesiologists class III and the remainder were class IV (38.3%) and V (1.7%). The procedure was completed in 180 patients (96.7%), with all 6 failures being access-related. The average procedure time was 149 minutes (range, 72 to 405). The 30-day mortality was 4.7% (9 patients), and serious morbidity was 19.9% (37 patients). Eight patients (4.3%) developed spinal cord ischemia, 4 immediately after the procedure and 4 delayed (1 to 3 days). Total hospital length of stay averaged 6.7 days. Secondary endovascular interventions were successful in 17 patients with angiographically confirmed endoleaks (type I and III). At an average follow-up of 40 months, freedom from all-cause mortality was 62.5% in group A and 58.1% in group B. CONCLUSIONS Stent-graft repair for TAA and TBAD can be achieved with high technical success and comparatively low rates of morbidity and mortality. Midterm survival appears to be favorable. Further refinements in device technology and procedural techniques are needed.
Collapse
Affiliation(s)
- Frank J Criado
- Center for Vascular Intervention, Division of Vascular Surgery, Union Memorial Hospital, MedStar Health, Baltimore, Maryland, USA.
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Moura MRL, Melissano G, Maisano F, Marone EM, Civilini E, Alfieri O, Chiesa R. Combined endovascular treatment of a descending thoracic aortic aneurysm and off-pump myocardial revascularization-a case report. Vasc Endovascular Surg 2004; 36:305-9. [PMID: 15599482 DOI: 10.1177/153857440203600409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Endovascular intervention is an alternative form of treatment for patients with thoracic aortic aneurysms. Coexistent cardiovascular diseases may adversely influence the postoperative course and affect the long-term prognosis. The case of a 76-year-old man with severe coronary artery disease and a thoracic aortic aneurysm is reported. A single-stage procedure of off-pump coronary artery revascularization and endoluminal exclusion of the descending thoracic aortic aneurysm was performed. The patient was treated first with off-pump coronary artery bypass graft (left internal mammary artery on the left anterior descending coronary artery and two single venous grafts from ascending aorta to obtuse marginal artery and posterior descending artery). After heart revascularization, two Thoracic Excluder endovascular grafts (34 x 100 and 37 x 100 mm) were implanted to treat the descending thoracic aortic aneurysm. Follow-up with computed tomography angiography showed successful exclusion of the thoracic aneurysm 12 months after the procedure. The patient is well and free of symptoms 18 months later.
Collapse
Affiliation(s)
- Marcelo R L Moura
- Department of Vascular Surgery, Università Vita-Salute, IRCCS H. San Raffaele, Milan, Italy
| | | | | | | | | | | | | |
Collapse
|
21
|
Tse LW, MacKenzie KS, Montreuil B, Obrand DI, Steinmetz OK. The proximal landing zone in endovascular repair of the thoracic aorta. Ann Vasc Surg 2004; 18:178-85. [PMID: 15253253 DOI: 10.1007/s10016-004-0008-7] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
In this study we evaluated the relationship between the site of the proximal landing zone during endovascular repair of thoracic aortic pathology and treatment outcomes. We reviewed all cases of endovascular repair of thoracic aortic lesions at our institution in the past 42 months. Thirty-seven Talent thoracic endografts were used to treat 20 thoracic aneurysms, 8 intramural hematomas, 6 aortic dissections, and 3 post-traumatic aneurysms. The proximal edge of the covered endograft was situated proximal to the left common carotid artery (zone 1) in 3 patients, between the left common carotid and subclavian arteries (zone 2) in 4 patients, <2 cm distal to the left subclavian artery (zone 3) in 9 patients, and >2 cm distal to the left subclavian (zone 4) in 21 patients. Five patients had extraanatomic bypass to revascularize one or more covered aortic branches. For zones 1, 2, 3, and 4 the endoleak rates were 100%, 0%, 11%, and 0%, respectively; the secondary procedure rates were 33%, 0%, 11%, and 5% respectively; and the treatment failure rates were 67%, 0%, 11%, and 0%, respectively (p < 0.05, for endoleak rates, using Fisher's exact test to compare zone 1 to zones 2, 3, and 4 individually, and as a group). All three endovascular failures were due to proximal type 1 endoleaks. In conclusion, despite the use of great-vessel ligation and extraanatomic bypass to extend the proximal landing zone into the aortic arch, we have been unable to reliably exclude thoracic aortic pathology through use of endografts when the proximal landing zone is proximal to the left common carotid artery.
Collapse
MESH Headings
- Aged
- Aged, 80 and over
- Aortic Dissection/diagnostic imaging
- Aortic Dissection/mortality
- Aortic Dissection/therapy
- Aneurysm, Ruptured/diagnostic imaging
- Aneurysm, Ruptured/mortality
- Aneurysm, Ruptured/therapy
- Aorta, Thoracic/diagnostic imaging
- Aorta, Thoracic/pathology
- Aorta, Thoracic/surgery
- Aortic Aneurysm, Thoracic/diagnostic imaging
- Aortic Aneurysm, Thoracic/mortality
- Aortic Aneurysm, Thoracic/therapy
- Canada
- Embolization, Therapeutic
- Female
- Follow-Up Studies
- Heart Arrest, Induced
- Humans
- Hypothermia, Induced
- Male
- Middle Aged
- Postoperative Complications/diagnostic imaging
- Postoperative Complications/etiology
- Postoperative Complications/mortality
- Survival Analysis
- Tomography, X-Ray Computed
- Treatment Outcome
- Vascular Surgical Procedures
Collapse
Affiliation(s)
- Leonard W Tse
- Division of Vascular Surgery, McGill University, Royal Victoria Hospital, Montreal, Quebec, Canada
| | | | | | | | | |
Collapse
|
22
|
Czermak BV, Fraedrich G, Perkmann R, Mallouhi A, Steingruber IE, Waldenberger P, Neuhauser B, Jung T, Jaschke WR. Endovascular repair of thoracic aortic disease: What we have learned. Curr Probl Diagn Radiol 2004; 33:269-82. [PMID: 15549052 DOI: 10.1067/j.cpradiol.2004.08.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
- Benedikt V Czermak
- Department of Radiology, Kurt Amplatz Center, University Hospital of Innsbruck, Austria.
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Abstract
The advent and success of endovascular repair of abdominal aneurysms had led to the development of catheter-based techniques to treat thoracic aortic pathology. Such diseases, including thoracic aortic aneurysms, acute and chronic type B dissections,penetrating aortic ulcers, and traumatic aortic transection, challenge surgeons to perform complex operative repairs in high-risk patients. The minimally invasive nature of thoracic endografting may provide an attractive alternative therapy especially in patients deemed unfit for thoracotomy. A worldwide review of thoracic endografting demonstrates encouraging short- and midterm outcomes with significant reductions in morbidity and early mortality.Long-term surveillance will be crucial to discover complications unique to thoracic endovascular interventions and to determine which patients are appropriate candidates for stent-graft therapy.
Collapse
Affiliation(s)
- Jason T Lee
- Division of Vascular Surgery H3600, Stanford University Medical Center, 300 Pasteur Drive, Stanford, CA 94305-5642, USA.
| | | |
Collapse
|
24
|
Goldstein B, Carroccio A, Ellozy SH, Spielvogel D, Morrissey N, Teodorescu V, Hollier LH, Marin ML. Combined open and endovascular repair of a syphilitic aortic aneurysm. J Vasc Surg 2004; 38:1422-5. [PMID: 14681652 DOI: 10.1016/s0741-5214(03)00943-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The use of endovascular stent grafts in the repair of thoracic aortic aneurysms has provided an alternative means of treatment, particularly in the high-risk patient who may not tolerate conventional open repair. The combination of conventional surgery and endovascular repair may allow for successful treatment in patients with anatomy unsuitable for repair entirely by endovascular means alone. We present the case of a patient with a syphilitic thoracic aortic aneurysm involving the aortic arch and descending thoracic aorta. He underwent a staged repair with an elephant trunk reconstruction of the aortic arch followed by endovascular repair of the descending thoracic aorta. This is the first reported case of the repair of a syphilitic aneurysm by means of endovascular techniques.
Collapse
Affiliation(s)
- Bethany Goldstein
- Department of Surgery, Mount Sinai Medical Center, 5 East 98th Street, 4th Floor, Box 1259, New York, NY 10029, USA.
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Lonn L, Delle M, Falkenberg M, Lepore V, Klingenstierna H, Radberg G, Risberg B. Endovascular Treatment of Type B Thoracic Aortic Dissections. J Card Surg 2003; 18:539-44. [PMID: 14992106 DOI: 10.1046/j.0886-0440.2003.00404.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the initial experience of endovascular repair of aortic dissections from a single center. MATERIALS AND METHODS From June 1999 to March 2002, endovascular stent grafting was performed in 20 high-risk patients (16 to 80 years). Eighteen patients had a type B dissection (14 acute and 4 chronic). Two patients had chronic type A dissection. Preoperative work-up included CT and MRI to evaluate the extent of the dissection, the relation to the left subclavian artery, the size of false and true lumen, and branch complications. RESULTS Stent-graft deployment was technically successful in all cases. None was converted to open repair. Three patients died within 30 days, i.e., a 15% mortality rate. Four patients (20%) had a perioperative stroke. Paraplegia was observed in one case. No migration of the stent grafts or endoleaks was observed during the mean follow-up period of 13 months. In all but two patient thrombosis of the false lumen was noted. CONCLUSIONS Endovascular treatment of thoracic dissections is feasible. Early results are encouraging. While endovascular repair with stent-grafts is progressing rapidly as a viable strategy for aortic dissections in selected patients careful investigations must continue to focus on its safety. Randomized controlled trials are urgently needed.
Collapse
Affiliation(s)
- Lars Lonn
- Department of Interventional Radiology, Sahlgrenska University Hospital, SE 413 45, Göteborg, Sweden.
| | | | | | | | | | | | | |
Collapse
|
26
|
Berthet JP, Marty-Ané CH, Veerapen R, Picard E, Mary H, Alric P. Dissection of the abdominal aorta in blunt trauma: endovascular or conventional surgical management? J Vasc Surg 2003; 38:997-1003; discussion 1004. [PMID: 14603206 DOI: 10.1016/s0741-5214(03)00613-x] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND Dissection of the abdominal aorta caused by blunt trauma is a rare injury, often complicated by thrombosis within the true and false lumens and sometimes aortic rupture. The mortality rate with conservative medical management is approximately 75%, whereas it ranges from 18% to 37% with surgical treatment. METHODS At our institution, 7 of the 87 patients admitted because of blunt aortic trauma, between January 1995 and January 2002, had abdominal aortic dissection. RESULTS Four patients were treated using endovascular techniques by percutaneous stent placement. The indications for endovascular management were lower limb ischemia in one case and extension of the dissection in two; one patient was asymptomatic. Aortic dissection was complicated by ischemic paraplegia in two patients, and both were treated by conventional operative repair. One patient was managed medically because of a minimal intimal disruption. No deaths were related to the aortic dissection or its treatment. Angiographic and computed tomographic (CT) studies showed thrombosis of the false lumen and complete obliteration of the dissection in the endovascular group. The neurologic condition of the two paraplegic patients either cleared completely or partially improved. CONCLUSION In the absence of ischemic paraplegia or other injuries that require emergency surgery, endovascular treatment is a safe and efficient method for treating traumatic infrarenal aortic dissection.
Collapse
|
27
|
Lepore V, Lönn L, Delle M, Mellander S, Rådberg G, Risberg B. Treatment of descending thoracic aneurysms by endovascular stent grafting. J Card Surg 2003; 18:436-43. [PMID: 12974934 DOI: 10.1046/j.1540-8191.2003.02079.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE Endovascular stent-graft treatment for true aneurysms of the descending thoracic aorta is a valid and effective alternative to conventional surgery. A review of our experience with 21 consecutive patients is reported and technical considerations are discussed. METHODS Twenty-one patients (mean age 73 years) with true aneurysms of the descending thoracic aorta (n = 14) or contained rupture (n = 7) were treated between October 1999 and July 2001. Seven patients (33%) underwent emergency endovascular procedure. Postoperatively, the patients were followed with CT scans at 1, 3, 6, and 12 months. Follow-up, which averaged 17 months, was 100% complete. THIRTY-DAY RESULTS: No conversions to open repair were necessary. Two patients died (10%), one of acute intestinal ischemia and the other because of multiorgan failure. Four patients showed endoleaks immediately after stenting. Two patients required new endovascular stentgrafts, while the remaining two were treated conservatively. Besides endoleaks, eight major complications occurred in six patients (two stroke, two paraplegia, two respiratory insufficiency, and one renal failure). MID-TERM RESULTS: Three more patients died during the follow-up period. One patient died of heart failure after a complicated postoperative course, 91 days after stenting. The second patient died because of aortic rupture, 139 days after stenting. The third patient died of heart failure, 15 months after the endovascular procedure. The remaining 16 patients are alive and have been regularly controlled by CT scans. No late migration or endoleaks have been detected. In all the survivors, the size of the aneurysm was unchanged or diminished. CONCLUSIONS Treatment of descending thoracic aortic aneurysms by endovascular stentgraft devices has good early and mid-term results. More accurate selection of patients may further reduce mortality and morbidity.
Collapse
Affiliation(s)
- V Lepore
- Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, University of Göteborg, SE 413-45 Göteborg, Sweden.
| | | | | | | | | | | |
Collapse
|
28
|
Abstract
BACKGROUND Thoracic aortic dissections, ruptures, fistulae, and aneurysms pose a unique surgical challenge. Traditional repair of thoracic aortic aneurysms involves thoracotomy with graft interposition. Despite advances in perioperative care and both total and partial cardiopulmonary bypass, conventional surgery carries a significant morbidity and mortality. Principal complications include bleeding, paraplegia, stroke, cardiac events, pulmonary insufficiency, and renal failure. Recent enthusiasm for innovative endovascular therapies to treat aortic disease has spurred many centers to investigate endoluminal grafting of the thoracic aorta. Early reports on endovascular repair using custom made "first generation devices" demonstrated the technique to be feasible with a mortality and morbidity comparable to open repair. METHODS AND RESULTS From February 2000 to February 2001, endovascular stent graft repair of the thoracic aorta was performed in 46 patients (mean age 70; 29 male and 17 female) using the Gore Excluder. Twenty-three patients (50%) had atherosclerotic aneurysms, fourteen patients (30%) had dissections, three patients (7%) had aortobronochial fistulas, three patients (7%) had pseudoaneurysms, two patients (4%) had traumatic ruptures, and one patient (2%) had a ruptured aortic ulcer. Patient characteristics, procedural variables, outcomes, and complications were recorded. All patients were followed with chest CT scans at 1, 3, 6, and 12 months. Mean follow up was 9 months ranging from 1 to 15 months. All procedures were technically successful. There were no conversions. Average duration of the procedure was 120 minutes. Average length of stay was 6 days, but most patients left the hospital within 4 days (64%) after endoluminal grafting. Overall morbidity was 23%. Two patients (4%) had endoleaks that required a second procedure for successful repair. Two patients (4%) died in the immediate postoperative period. There were no cases of paraplegia. At follow-up, one patient had an endoleak found the day after the procedure and another patient had an endoleak 6 moths post procedure. Both were treated successfully with additional stent grafts. There were no cases of migration. One patient died of a myocardial infarction 6 months after graft placement. The Gore Excluder device was voluntarily recalled on February 26, 2001. Therefore, from June 2000 to January 2001, 37 patients underwent endovascular stent graft repair of the thoracic aorta for various disease entities using our customized thoracic graft (Endomed). Twenty-seven patients (73%) had aneurysms, six (16%) had dissections, two (5%) had pseudoaneurysms, one (2%) had a traumatic transection, and one patient (2%) had an embolizing ulcer. Patients were followed with CT scans at 1, 3, 6, and 12 months. All procedures were technically successful. There were no conversions. The average age was 68 years.(17-87). And the male and female ratio was 24/13. One patient died in the operating room from iliac rupture and one died from embolization/stroke in the immediate postoperative period. Two patients died within 30 days from comorbid factors. The total 30-day mortality was 10%. Two patients had endoleaks. One returned to the operating room and needed an additional cuff. The other had a small leak in a proximal dissection that is being followed. There were no cases of paraplegia. CONCLUSION Thoracic endoluminal grafting is a safe and feasible alternative to open graft repair and can be performed successfully with good results. Early data suggest that an endoluminal approach to these disease entities maybe favorable to open resection and graft replacement. Technical details of Endoluminal stent grafting of the thoracic aorta for different disease entities have been discussed at length.
Collapse
Affiliation(s)
- Venkatesh Ramaiah
- Department of Cardiovascular and Endovascular Surgery, Arizona Heart Institute, 2632 N. 20th Street, Phoenix, AZ 85006, USA.
| | | | | |
Collapse
|
29
|
O'Neill-Kerr D, Brew M, Shaw D, Buckenham T. Endoluminal stent graft placement for acute traumatic injury of the thoracic aorta in a patient with multiple coexisting injuries. ANZ J Surg 2003; 73:776-8. [PMID: 12956802 DOI: 10.1046/j.1445-2197.2003.02736.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
- David O'Neill-Kerr
- Department of Radiology, Christchurch Public Hospital, Christchurch, New Zealand.
| | | | | | | |
Collapse
|
30
|
Gowda RM, Misra D, Tranbaugh RF, Ohki T, Khan IA. Endovascular stent grafting of descending thoracic aortic aneurysms. Chest 2003; 124:714-9. [PMID: 12907563 DOI: 10.1378/chest.124.2.714] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
The treatment of descending thoracic aortic aneurysms using endovascular stents is one of the more recent advances in treatment and is receiving increasing attention as it is a less invasive alternative to open surgical repair. Although the technology is still primitive, significant improvements have lately been made in the design and deployment of the endovascular stent-grafts. Aortic stent-grafts were used initially to exclude abdominal, and later thoracic, aortic true and false aneurysms. These prostheses have been increasingly used to treat aneurysms, dissections, and traumatic ruptures of the descending thoracic aorta with good early and mid-term outcomes. Although the long-term outcome of patients with aneurysms of the descending thoracic aorta after stent graft implantation has not been investigated, continued refinement of the endovascular approaches has decreased the need for conventional open thoracic aortic aneurysm repair, especially in patients who are at a high risk for standard surgery because of advanced age or the presence of comorbid diseases. The placement of endoluminal stent-grafts to exclude the dissected or ruptured site of thoracic aortic aneurysms is a technically feasible and relatively safe procedure. With the rapid development of endovascular approaches, the treatment of the descending thoracic aortic aneurysms might alter even more, but an extended follow-up is necessary to determine the longer term outcome. Historical perspectives, advantages, device considerations, complications, and current perspectives of the endovascular stent grafting of the descending thoracic aortic aneurysms are elaborated on.
Collapse
Affiliation(s)
- Ramesh M Gowda
- Division of Cardiology, Beth Israel Medical Center, New York, NY, USA
| | | | | | | | | |
Collapse
|
31
|
Hance KA, Hsu J, Eskew T, Hermreck AS. Secondary aortoesophageal fistula after endoluminal exclusion because of thoracic aortic transection. J Vasc Surg 2003; 37:886-8. [PMID: 12663993 DOI: 10.1067/mva.2003.159] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Secondary aortoesophageal fistula (AEF) is a rare but catastrophic complication that occurs after thoracic aortic reconstruction. Recently endoluminal stent grafts have been used in selected patients with a thoracic aortic aneurysm, dissection, or traumatic aortic transection. A 24-year-old woman had massive upper gastrointestinal tract bleeding 15 months after endoluminal stent graft placement because of traumatic descending thoracic aortic transection. Evaluation demonstrated an AEF from the mid-esophagus to the endoluminal stent graft. The endoluminal graft was explanted, with primary repair of the thoracic aortic defect and simultaneous primary repair of the esophageal injury. The patient is well 15 months after open repair of the AEF.
Collapse
Affiliation(s)
- Kirk A Hance
- Department of Surgery, Section of Vascular Surgery, University of Kansas Medical Center, Kansas City, 66160, USA.
| | | | | | | |
Collapse
|
32
|
Lopera J, Patiño JH, Urbina C, García G, Alvarez LG, Upegui L, Jhanchai A, Qian Z, Castañeda-Zuñiga W. Endovascular treatment of complicated type-B aortic dissection with stent-grafts:: midterm results. J Vasc Interv Radiol 2003; 14:195-203. [PMID: 12582187 DOI: 10.1097/01.rvi.0000058321.82956.76] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To report the midterm results of the endovascular treatment of complicated type-B aortic dissection with use of stent-grafts. MATERIALS AND METHODS Ten patients with acute (n = 4) or chronic (n = 6) complicated type-B dissection were treated with custom-made stent-grafts. Indications for treatment included uncontrollable hypertension with dissection extension (n = 3), renal ischemia (n = 1), and false lumen aneurysm (n = 6). Stainless-steel Z-stents covered with polyester grafts were placed in the initial six patients. Nitinol stents covered with ultrathin polytetrafluoroethylene were used in the remaining four patients. The patients were followed-up with helical computed tomography for a maximum of 30 months (mean, 20 mo). RESULTS There was one technical failure related to the access site. Early complications included deep venous thrombosis (n = 1) and embolic stroke (n = 1). Complete thrombosis of the thoracic false lumen was achieved in six patients and partial thrombosis was achieved in three. Aneurysms developed at the ends of the stainless-steel stents in two patients, requiring additional stent-graft placement. Despite successful remodeling of the thoracic aorta, three of four patients with distal reentry into the abdominal aorta experienced progressive abdominal aortic aneurysm (AAA). AAA rupture developed in two patients; one rupture was fatal and the other was treated with emergency surgery. CONCLUSIONS Endovascular treatment of complicated type-B aortic dissection is technically feasible and effective. Closely monitoring the treated aorta is essential to detect early aneurysm formation at the ends of rigid stents. Despite adequate sealing of the tears in the thoracic aorta, dissection with distal reentry phenomenon into the abdominal aorta may evolve into AAA with late rupture.
Collapse
Affiliation(s)
- Jorge Lopera
- Department of Radiology, Louisiana State University at New Orleans, 1542 Tulane Avenue, New Orleans, Louisiana 70112,
| | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Orend KH, Scharrer-Pamler R, Kapfer X, Kotsis T, Görich J, Sunder-Plassmann L. Endovascular treatment in diseases of the descending thoracic aorta: 6-year results of a single center. J Vasc Surg 2003; 37:91-9. [PMID: 12514583 DOI: 10.1067/mva.2003.69] [Citation(s) in RCA: 134] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate endovascular treatment in diseases of the descending thoracic aorta. MATERIAL AND METHODS This study was designed as a single center's (university hospital) experience. Over a 6-year period (1995 to 2001), thoracic endografts were placed in 74 patients with a diseased descending thoracic aorta who were at high risk for conventional open surgical repair: 34 had atherosclerotic aneurysms, six had posttraumatic aneurysms, 14 had type B dissection with aneurysmal dilatation of the false lumen, 12 had isthmic transections from blunt trauma, five had thoracoabdominal aneurysms (treated with a combined procedure), two had aortic coarctation, and one had an aortobronchial fistula. Twenty-six procedures (35.1%) were conducted as emergencies, and 48 (64.9%) were elective. The feasibility of endovascular treatment and sizing of stent grafts were determined with preoperative spiral computed tomography and intraoperative angiography. RESULTS Endovascular operations were completed successfully in all 74 patients; postprocedural conversion to open repair was necessary in three cases. The overall 30-day mortality rate was 9.5% (seven deaths). Temporary neurologic deficits developed in two patients; not one patient had permanent paraplegia. The primary endoleak rate was 20.3% (15 patients). The mean follow-up period was 22 months (range, 3 to 72 months). Five deaths occurred in the follow-up period, and three patients needed secondary conversion to open repair 2, 3, and 14 months after initial endografting. CONCLUSION Endoluminal treatment in diseases of the thoracic descending aorta is feasible and may offer results as good as the open method.
Collapse
Affiliation(s)
- K H Orend
- Department of Thoracic and Vascular Surgery, University of Ulm, Ulm, Germany.
| | | | | | | | | | | |
Collapse
|
34
|
Pamler RS, Kotsis T, Görich J, Kapfer X, Orend KH, Sunder-Plassmann L. Complications After Endovascular Repair of Type B Aortic Dissection. J Endovasc Ther 2002. [DOI: 10.1583/1545-1550(2002)009<0822:caerot>2.0.co;2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
35
|
Lepore V, Lönn L, Delle M, Bugge M, Jeppsson A, Kjellman U, Rådberg G, Risberg B. Endograft therapy for diseases of the descending thoracic aorta: results in 43 high-risk patients. J Endovasc Ther 2002; 9:829-37. [PMID: 12546585 DOI: 10.1177/152660280200900617] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To report an initial experience with endovascular stent-graft implantation for diseases of the descending thoracic aorta in high-risk patients. METHODS Forty-three patients (28 men; mean age 67 years, range 17-82) with 16 descending thoracic aortic dissections, 14 aneurysms, 7 contained ruptures, 3 mycotic aneurysms, 2 posttraumatic pseudoaneurysms, and an aneurysm of an anomalous right subclavian artery were treated between June 1999 and July 2001. Twenty-three (53%) patients were treated emergently. RESULTS There were no conversions to open repair, but 3 (7%) patients died during the first 30 days (pneumonia, multiorgan failure, and acute bowel ischemia). Thirteen (30%) patients suffered 18 major complications (8 strokes, paraplegia in 3, respiratory insufficiency in 6, and 1 renal failure). Of 7 (16%) endoleaks detected in the early postoperative period, 3 required additional stents, while the other 4 were treated conservatively. Follow-up, which averaged 19 +/- 6 months (median: 13; range 0-34), was 100% complete. Five (12%) patients died: 3 of aortic rupture at 34, 47, and 139 days, respectively, and 2 from heart failure at 3 and 15 months, respectively. No late migration or endoleaks have been detected in the remaining 35 patients; however, 1 (2%) patient showed progressive aortic dissection proximal to the stent-graft. In all other cases, the size of the aneurysm or the false lumen was unchanged or diminished. CONCLUSIONS Treatment of descending thoracic aortic diseases with an endovascular approach has acceptable early mortality and morbidity in high-risk patients. In selected cases, stent-grafts may afford the best therapy.
Collapse
Affiliation(s)
- Vincenzo Lepore
- Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Göteborg, Sweden.
| | | | | | | | | | | | | | | |
Collapse
|
36
|
Pamler RS, Kotsis T, Görich J, Kapfer X, Orend KH, Sunder-Plassmann L. Complications after endovascular repair of type B aortic dissection. J Endovasc Ther 2002; 9:822-8. [PMID: 12546584 DOI: 10.1177/152660280200900616] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To outline the complications encountered after endoluminal treatment in patients with type B aortic dissection. METHODS Between 1999 and 2001, 14 patients (12 men; mean age 60.3 years, range 39-79) with isolated type B aortic dissection (13 chronic, 1 acute) underwent aortic stent-grafting. Three patients with chronic dissection presented an acute clinical picture and were managed emergently. The left subclavian artery was intentionally covered by the prosthesis in 9 patients. Follow-up studies were performed at 6-month intervals. RESULTS Stent-graft implantation was technically successful in all patients, but incomplete sealing (endoleak) of the entry site required additional proximal stent-graft implantation in 4. The left subclavian artery remained patent in 5 patients. Secondary conversion was required in 3 patients: 2 for acute type A dissection resulting from injury to the aortic arch by Talent endografts and a sustained hemorrhage (left hemothorax). In another patient, a secondary intramural hematoma subsided spontaneously. Anterior spinal artery syndrome in 1 patient persisted at 1 month. No bypass was necessary for the 9 patients with the covered left subclavian arteries. Mean follow-up was 14 months (range 1-23). CONCLUSIONS Stent-grafting is feasible in patients with type B aortic dissection, although it is associated with a considerable rate of complications. Frank reporting of these sequelae for a variety of stent-grafts is of paramount importance to clarifying the limitations of the method.
Collapse
Affiliation(s)
- Reinhard S Pamler
- Department of Thoracic and Vascular Surgery, University of Ulm, Germany.
| | | | | | | | | | | |
Collapse
|
37
|
Lepore V, Lönn L, Delle M, Bugge M, Jeppsson A, Kjellman U, Rådberg G, Risberg B. Endograft Therapy for Diseases of the Descending Thoracic Aorta:Results in 43 High-Risk Patients. J Endovasc Ther 2002. [DOI: 10.1583/1545-1550(2002)009<0829:etfdot>2.0.co;2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
38
|
Buffolo E, da Fonseca JHP, de Souza JAM, Alves CMR. Revolutionary treatment of aneurysms and dissections of descending aorta: the endovascular approach. Ann Thorac Surg 2002; 74:S1815-7; discussion S1825-32. [PMID: 12440672 DOI: 10.1016/s0003-4975(02)04138-3] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND Acute aortic dissection is a life-threatening medical condition. It is associated with high morbidity and mortality. Type B dissections are usually managed clinically during the acute phase. Conventional surgery carries high mortality rates due to the presence of serious complications. We herein present treatment of this condition with a less invasive endovascular approach. Other clinical situations such as penetrating ulcers, intramural hematomas, and true aneurysms of descending aorta were similarly treated. METHODS From December 1996 to March 2002, 191 patients with type B dissections were treated with self-expandable, polyester-covered stents. There were 120 patients (62.8%) with type B dissections, 61 patients (31.9%) with true aneurysms, 6 patients (3.1%) with penetrating ulcers or intramural hematomas, and 4 patients (2.1%) with trauma. Patients with abdominal aneurysms (44) and stents introduced under direct vision through the aortic arch (70) were excluded. The stent graft was delivered in the catheterization laboratory under general anesthesia, with induced hypotension and heparinization. All stents used were made in Brazil (Braile Biomedics, Sao Jose do Rio Preto, SP). RESULTS The procedure was performed in 191 consecutive cases. The success rate was 91.1% (174/191). Success was defined as occlusion of the thoracic intimal tear, or exclusion of the aneurysm without leaks. Hospital mortality was 10.4% (20/191 patients), due to preoperative comorbidities. Six patients required conversion to surgery. No case of paraplegia was observed. An actuarial survival curve showed 87.4% +/- 29% survival in the late follow-up period. CONCLUSIONS Stent grafts are an important development in the treatment of descending aortic aneurysms or dissections. This novel approach may replace conventional surgical treatment of these conditions, with earlier intervention and less morbidity.
Collapse
Affiliation(s)
- Enio Buffolo
- Federal University of São Paulo, Paulista School of Medicine and Affiliated Hospitals, SP, Brazil.
| | | | | | | |
Collapse
|
39
|
Latessa V. Endovascular stent-graft repair of descending thoracic aortic aneurysms: the nursing implications for care. JOURNAL OF VASCULAR NURSING 2002; 20:86-93. [PMID: 12370690 DOI: 10.1067/mvn.2002.127736] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Endovascular repair of descending thoracic aortic aneurysms is a minimally invasive procedure performed with the patient under epidural or spinal anesthesia as an alternative to the conventional left thoracotomy repair. A Dacron graft, similar to the one used in the conventional repair, is placed in the thoracic aorta with fluoroscopic guidance via the femoral or iliac artery. Once the graft is in place, the aneurysm is excluded from the general circulation, thereby preventing rupture. Endovascular repair is currently being offered at selected sites to patients who otherwise would not be candidates for surgical repair due to severe comorbidities such as cardiac, pulmonary, or renal disease. As both the technique and the devices become perfected, endovascular stent-graft repair of descending thoracic aortic aneurysms will most likely be offered as a method of treatment in both high- and low-risk patients who are anatomic candidates for the procedure. This article describes the conventional repair and the endovascular repair of descending thoracic aneurysms. It discusses the implications for nursing care in the preoperative and postoperative settings and defines guidelines for the long-term follow-up of patients who undergo endovascular repair.
Collapse
|
40
|
Czermak BV, Waldenberger P, Perkmann R, Rieger M, Steingruber IE, Mallouhi A, Fraedrich G, Jaschke WR. Placement of endovascular stent-grafts for emergency treatment of acute disease of the descending thoracic aorta. AJR Am J Roentgenol 2002; 179:337-45. [PMID: 12130430 DOI: 10.2214/ajr.179.2.1790337] [Citation(s) in RCA: 78] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the feasibility, safety, and effectiveness of endovascular stent-graft placement for the emergency treatment of acute descending thoracic aortic disease. MATERIALS AND METHODS From January 1996 through November 2001, 18 patients underwent emergency endovascular stent-graft placement for various types of acute descending thoracic aortic disease. Five patients had Stanford type B aortic dissection, six had traumatic ruptures of the thoracic aorta, five had ruptured aortic aneurysms, and two had penetrating atherosclerotic aortic ulcers. All patients presented with life-threatening symptoms requiring treatment with stent-grafts from the emergency kit. All were at high surgical risk due to serious comorbidities. The efficacy of the procedure was assessed at follow-up studies before discharge and at 3, 6, and 12 months after intervention and yearly thereafter. RESULTS The primary technical success rate was 78%. Four patients had primary perigraft leaks. The secondary technical success rate was 83%. One patient died 20 hr after intervention from stent-graft-related causes. Follow-up studies revealed stent-graft migration in one patient. Progression of disease was observed in one patient treated for dissection and in both patients treated for penetrating ulcers. One patient died 7 months after intervention of unknown reasons; all other patients are alive. The mean follow-up time was 17.4 months (range, 0-38 months). CONCLUSION Emergency repair of acute descending thoracic aortic disease with stent-graft placement can be successfully accomplished and may be a promising alternative to open-chest surgery, especially in patients at high risk.
Collapse
Affiliation(s)
- Benedikt V Czermak
- Department of Radiology, Kurt Amplatz Center, Leopold-Franzens Medical School and University Hospital Innsbruck, Anichstr. 35, 6020 Innsbruck, Austria
| | | | | | | | | | | | | | | |
Collapse
|
41
|
Abstract
The incidence of aortic dissection ranges from 5 to 30 cases per million people per year, depending on the prevalence of risk factors in the study population. Although the disease is uncommon, its outcome is frequently fatal, and many patients with aortic dissection die before presentation to the hospital or prior to diagnosis. While pain is the most common symptom of aortic dissection, more than one-third of patients may develop a myriad of symptoms secondary to the involvement of the organ systems. Physical findings may be absent or, if present, could be suggestive of a diverse range of other conditions. Keeping a high clinical index of suspicion is mandatory for the accurate and rapid diagnosis of aortic dissection. CT scanning, MRI, and transesophageal echocardiography are all fairly accurate modalities that are used to diagnose aortic dissection, but each is fraught with certain limitations. The choice of the diagnostic modality depends, to a great extent, on the availability and expertise at the given institution. The management of aortic dissection has consisted of aggressive antihypertensive treatment, when associated with systemic hypertension, and surgery. Recently, endovascular stent placement has been used for the treatment of aortic dissection in select patient populations, but the experience is limited. The technique could be an option for patients who are poor surgical candidates, or in whom the risk of complications is gravely high, especially so in the patients with distal dissections. The clinical, diagnostic, and management perspectives on aortic dissection and its variants, aortic intramural hematoma and atherosclerotic aortic ulcer, are reviewed.
Collapse
Affiliation(s)
- Ijaz A Khan
- Division of Cardiology, Department of Medicine, Creighton University School of Medicine, Omaha, NB, USA.
| | | |
Collapse
|
42
|
Thompson CS, Gaxotte VD, Rodriguez JA, Ramaiah VG, Vranic M, Ravi R, DiMugno L, Shafique S, Olsen D, Diethrich EB. Endoluminal stent grafting of the thoracic aorta: initial experience with the Gore Excluder. J Vasc Surg 2002; 35:1163-70. [PMID: 12042726 DOI: 10.1067/mva.2002.122885] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE The purpose of this study was to describe our experience with endoluminal graft repair of a variety of thoracic aorta pathologies with a commercially developed device currently under investigation. Our patient population included patients eligible for open surgical repair and those with prohibitive surgical risk. METHODS From February 2000 to February 2001, endovascular stent-graft repair of the thoracic aorta was performed in 46 patients (mean age, 70 years; 29 male and 17 female patients) with the Gore Excluder. Twenty-three patients (50%) had atherosclerotic aneurysms, 14 patients (30%) had dissections, three patients (7%) had aortobronchial fistulas, three patients (7%) had pseudoaneurysms, two patients (4%) had traumatic ruptures, and one patient (2%) had a ruptured aortic ulcer. Patient characteristics, procedural variables, outcome, and complications were recorded. All patients were followed with chest computed tomographic scans at 1, 3, 6, and 12 months. Follow-up period ranged from 1 month to 15 months, with a mean of 8.5 months. RESULTS All the procedures were technically successful. There were no conversions. Average duration of the procedure was 120 minutes. Average length of stay was 6 days, but most patients (64%) left the hospital within 4 days after endoluminal grafting. The overall morbidity rate was 23%. Two patients (4%) had endoleaks that necessitated a second procedure for successful repair. Two patients (4%) died in the immediate postoperative period. There were no cases of paraplegia. At follow-up examination, one patient had an endoleak found the day after the procedure and another patient had an endoleak 6 months after the procedure. Both cases were treated successfully with additional stent-grafts. There were no cases of migration. One patient died of a myocardial infarction 6 months after graft placement. In patients treated for aneurysm (n = 23), the aneurysm diameter ranged from 5.0 to 9.5 cm (mean, 6.8 cm). Residual sac measurements were obtained at 1, 6, and 12 months, with mean sac reductions of 0.59 cm, 0.77 cm, and 0.85 cm, respectively. In three cases, the sac remained unchanged, without evidence of endoleak. CONCLUSION Thoracic endoluminal grafting with the Gore Excluder is a safe and feasible alternative to open graft repair and can be performed successfully with good results. Early data suggest an endoluminal approach to these disease entities may be favorable over classical resection and graft replacement.
Collapse
Affiliation(s)
- Charles S Thompson
- Department of Cardiovascular and Endovascular Surgery, Arizona Heart Institute and Hospital, 2632 N 20th Street, Phoenix, AZ 85006, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Affiliation(s)
- Juan P Umana
- Stanford University School of Medicine, California 94305-5407, USA
| | | |
Collapse
|
44
|
Rodrigues Alves CM, da Fonseca JHP, de Souza JAM, Camargo Carvalho AC, Buffolo E. Endovascular treatment of thoracic disease: patient selection and a proposal of a risk score. Ann Thorac Surg 2002; 73:1143-8. [PMID: 11996255 DOI: 10.1016/s0003-4975(02)03386-6] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Although selection criteria and subgroup analysis are still in the early developmental stages, endovascular treatment of aortic disease has become an alternative to surgery for many patients. METHODS From November 1996 to November 1999, 49 patients were treated with a self-expandable endoprosthesis at our institution. Most patients had acute aortic dissections. Thirteen of these patients did not follow the anatomic selection protocol. We retrospectively analyzed these patients to compare our numerical risk score (which includes clinical and anatomic criteria) between groups with or without success and between groups that followed the anatomic protocol (P) or did not follow the anatomic protocol (E [exception]). RESULTS Success rates were similar in groups P and E, although mortality rates were higher in group E. Patients from group E had longer procedures and required multiple stents more frequently. The proposed risk score was able to differentiate between groups with or without success, as well as between groups P and E. CONCLUSIONS In order to reduce mortality and morbidity rates, careful selection criteria must be followed when treating patients endovascularly. Although it is time-consuming, using objective criteria can help select patients for endovascular treatment. We propose that patients with a risk score higher than 11 should only undergo percutaneous treatment when they have an unacceptably high surgical risk, and even so only after a detailed discussion of the risks.
Collapse
|
45
|
Thompson CS, Ramaiah VG, Rodriquez-Lopez JA, Vranic M, Ravi R, DiMugno L, Shafique S, Olsen D, Diethrich EB. Endoluminal stent graft repair of aortobronchial fistulas. J Vasc Surg 2002; 35:387-91. [PMID: 11854740 DOI: 10.1067/mva.2002.118583] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To describe our experience with endoluminal stent graft repair of aortobronchial fistulas. METHODS We reviewed the records of patients treated with endoluminal stent grafting of aortobronchial fistulas at a private teaching hospital. All patients underwent the following diagnostic studies: computed tomography, angiography, bronchoscopy, and transesophageal echocardiography. With standard endovascular techniques, two different devices were implanted. RESULTS Between March 1997 and October 2000, we treated four patients with postsurgical fistulas. The patients were diagnosed with hemoptysis between 3 and 23 years after aortic replacement grafting for thoracic aneurysms. Diagnostic studies varied in their ability to find the fistula. Transesophageal echocardiography most reliably demonstrated the fistula in the patients. All were successfully treated by exclusion with endoluminal stent grafting. The patients had no complications and no further episodes of hemoptysis. CONCLUSION Endoluminal stent grafting of aortobronchial fistulas is feasible and may become the preferred method of management in patients at high risk.
Collapse
Affiliation(s)
- Charles S Thompson
- Department of Cardiovascular Surgery, Arizona Heart Institute and Arizona Heart Hospital, Phoenix 85016, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Milner R, Bavaria JE, Baum RA, Carpenter JP, Velazquez OC, Brinster D, Fairman RM. Thoracic aortic stent grafts. Semin Roentgenol 2001; 36:340-50. [PMID: 11715329 DOI: 10.1053/sroe.2001.29163] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- R Milner
- Department of Surgery, Division of Vascular Surgery, University of Pennsylvania Medical Center, 3400 Spruce St, 4 Silverstein Pavilion, Philadelphia, PA 19104, USA
| | | | | | | | | | | | | |
Collapse
|
47
|
Czermak BV, Fraedrich G, Schocke MF, Steingruber IE, Waldenberger P, Perkmann R, Rieger M, Jaschke WR. Serial CT Volume Measurements After Endovascular Aortic Aneurysm Repair. J Endovasc Ther 2001. [DOI: 10.1583/1545-1550(2001)008<0380:scvmae>2.0.co;2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
48
|
Singh MJ, Rohrer MJ, Ghaleb M, Kim D. Endoluminal stent-graft repair of a thoracic aortic transection in a trauma patient with multiple injuries: case report. THE JOURNAL OF TRAUMA 2001; 51:376-81. [PMID: 11493803 DOI: 10.1097/00005373-200108000-00026] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Affiliation(s)
- M J Singh
- Divisions of Vascular Surgery, University of Massachusetts Medical School, Worcester, Massachusetts 01655, USA.
| | | | | | | |
Collapse
|
49
|
Czermak BV, Fraedrich G, Schocke MF, Steingruber IE, Waldenberger P, Perkmann R, Rieger M, Jaschke WR. Serial CT volume measurements after endovascular aortic aneurysm repair. J Endovasc Ther 2001; 8:380-9. [PMID: 11552730 DOI: 10.1177/152660280100800407] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the efficacy of transluminal stent-graft placement in aortic aneurysms using postoperative enhanced spiral computed tomographic (CT) volumetric measurements of the aneurysm sac, the intra-aneurysmal vascular channel (IAVC), the thrombus, and the stent-graft. METHODS Among 53 patients (45 men; mean age 74 years, range 59-85) who underwent elective endovascular aortic aneurysm repair, 37 patients with 27 abdominal and 10 thoracic aortic aneurysms completed at least a 6-month follow-up that included computerized CT volumetric analysis prior to discharge and at 3, 6, 12, 24, and 36 months. A variety of bifurcated (n = 23) and tube (n = 14) stent-grafts were observed for signs of endoleak and aneurysm enlargement. RESULTS Mean follow-up was 16 months (range 6-48). Total aneurysm volumes and thrombus volumes decreased, whereas IAVC and stent-graft volumes increased over time. Between the postoperative and 12-month imaging studies, reductions in total aneurysm (p 0.011) and thrombus (p < 0.001) volumes were significant. No statistically significant difference in volume changes for the aneurysm sac (p = 0.555) or the thrombus (p = 0.920) was found when comparing the 24 patients without primary leak to the 12 with primary type-II leak. In all 5 cases with secondary leak, the volume of the aneurysm sac increased after initial shrinkage. CONCLUSIONS Postoperative CT volumetric analysis is an effective tool for evaluating the outcome of endovascular aortic aneurysm repair. Thrombus volume measurements are more accurate than total aneurysm volumes. In patients in whom contrast agents are contraindicated, volume measurements can also be obtained without the use of contrast.
Collapse
Affiliation(s)
- B V Czermak
- Department of Radiology, Leopold-Franzens Medical School and University Hospital, Innsbruck, Austria.
| | | | | | | | | | | | | | | |
Collapse
|
50
|
Resch T, Koul B, Dias NV, Lindblad B, Ivancev K. Changes in aneurysm morphology and stent-graft configuration after endovascular repair of aneurysms of the descending thoracic aorta. J Thorac Cardiovasc Surg 2001; 122:47-52. [PMID: 11436036 DOI: 10.1067/mtc.2001.113025] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVE We sought to study changes in morphology and stent-graft configuration of descending thoracic aortic aneurysms after endovascular repair. METHODS Twenty-three patients treated with custom-made stent-grafts were studied. The stent-graft consisted of continuous, stainless-steel Z stents mounted within a polyester graft. In the last 11 cases the stents were interconnected with 3 longitudinal wires. Contrast-enhanced spiral computed tomography was performed preoperatively and at 1, 3, and every 6 months postoperatively. Angiography was used preoperatively and at 1-year follow-up. Proximal and distal necks were assessed for diameter and length. Aneurysm diameter, endoleaks, stent-graft migration, and changes in stent-graft configuration were evaluated. RESULTS During follow-up (median, 18 months; range, 1-48 months), excluded aneurysms decreased in diameter by 4 mm (0.5-10 mm, P =.0018). Endoleaks prevented size decrease. Five patients displayed neck dilatation, 4 at both the proximal and distal fixation sites and 1 only distally. In 7 (30%) patients there was proximal migration of the distal end of the stent-graft. Three (13%) patients displayed both distal migration of the proximal end of the stent-graft and proximal migration of the distal end of the stent-graft. There was a significant correlation between stent-graft kinking and appearance of proximal or distal stent-graft migration (P =.05 and P =.0007, respectively). In no case did the migration lead to appearance of an endoleak before intervention was performed. CONCLUSION Excluded descending thoracic aortic aneurysms decrease in size on midterm follow-up. A subgroup of patients prone to neck dilatation might exist. A combination of neck dilatation and vector forces acting on stent-grafts in the tortuous thoracic aorta might lead to stent-graft migration.
Collapse
Affiliation(s)
- T Resch
- Department of Surgery, Malmö University Hospital, Malmö, Sweden
| | | | | | | | | |
Collapse
|