Tawes RL, Sydorak GR, Duvall TB, Scribner RG, Rosenman JE, Beare JP, Harris EJ. Avoiding coagulopathy in vascular surgery.
Am J Surg 1990;
160:212-6. [PMID:
2382776 DOI:
10.1016/s0002-9610(05)80309-5]
[Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The possibility of coagulopathy can be minimized by attending to certain general perioperative details to avoid hypothermia, hypotension-shock, and multiple transfusions. In this paper, we present our protocol for avoiding coagulopathy in vascular surgery. In the past 1 1/2 years, we have used perioperative plasmapheresis in 204 patients undergoing cardiac or aortic peripheral vascular surgery. Autologous platelet-rich plasma is transfused at the completion of the operation after heparin reversal. Our data show an approximate 50% reduction in homologous blood product requirement. Seventy-five percent of patients having aortic surgery received no homologous blood products during their hospital stay. For those undergoing cardiac surgery, there has been about a 45% reduction in the use of homologous blood products. In our experience, autologous platelet-rich plasma not only decreases the risk of transmittable disease, but promotes hemostasis.
Collapse