1
|
Sahadi BO, Sebold M, André CB, Nima G, Dos Santos A, Chiari MDESDC, Nascimento FD, Tersariol ILDS, Giannini M. Effect of experimental dentin etchants on dentin bond strength, metalloproteinase inhibition, and antibiofilm activity. Dent Mater 2024; 40:e12-e23. [PMID: 38368137 DOI: 10.1016/j.dental.2024.02.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 02/12/2024] [Accepted: 02/12/2024] [Indexed: 02/19/2024]
Abstract
OBJECTIVE this study evaluated dentin microtensile bond strength (µTBS) and failure modes (at 24 h and one year), bonding interface regarding hybridization, surface morphology regarding demineralization, in situ metalloproteinase (MMP) activity, and antibacterial effect of three dentin etchants compared to 35% phosphoric acid (PA). MATERIALS AND METHODS The Adper Single Bond 2 adhesive (3 M Oral Care) was applied on moist dentin etched with PA (control) or on air-dried dentin etched with 3% aluminum nitrate + 2% oxalic acid (AN), 6.8% ferric oxalate + 10% citric acid (FO), or 10% citric acid (CA). The µTBS test used 40 human teeth (n = 10). Failure modes and surface morphology were analyzed by scanning electron microscopy (n = 3), while bonding interface morphology and MMP activity were evaluated by laser scanning confocal microscopy (n = 3). Antibacterial activity was evaluated against S. Mutans biofilm by means of viable cells count (CFU/mL). RESULTS PA presented the highest bond strengths regardless of aging time. PA, AN, and CA showed stable bond strengths after one year of storage. Adhesive and mixed failures were predominant in all groups. Thin hybrid layers with short resin tags were observed for the experimental etchants. The AN-based etchant was able to inhibit MMP activity. All tested etchants presented antibacterial activity against S. Mutans biofilm. SIGNIFICANCE This study suggests different dentin etchants capable of inhibiting MMP activity while also acting as cavity disinfectants.
Collapse
Affiliation(s)
- Beatriz Ometto Sahadi
- Department of Restorative Dentistry, Operative Dentistry Division, University of Campinas, Piracicaba Dental School, Avenida Limeira 901, Areião, 13414-903 Piracicaba, SP, Brazil.
| | - Maicon Sebold
- Department of Restorative Dentistry, Operative Dentistry Division, University of Campinas, Piracicaba Dental School, Avenida Limeira 901, Areião, 13414-903 Piracicaba, SP, Brazil.
| | - Carolina Bosso André
- Department of Restorative Dentistry, Operative Dentistry Division, Federal University of Minas Gerais, School of Dentistry, Avenida Presidente Antonio Carlos 6627, Pampulha, 31270-901 Belo Horizonte, MG, Brazil.
| | - Gabriel Nima
- Department of Biomedical Sciences, Ethics, Research and Education, Universidad de los Andes, School of Dentistry, Monseñor Álvaro del Portillo 12455, Las Condes 12455, Santiago, Chile.
| | - Andressa Dos Santos
- Applied Chemistry Graduate Program, Midwest State University UNICENTRO, Alameda Élio Antônio Dalla Vechhia 838, Vila Carli, 85040-167 Guarapuava, PR, Brazil.
| | | | - Fábio Dupart Nascimento
- Department of Molecular Biology, Federal University of São Paulo, São Paulo 04021-001, SP, Brazil.
| | | | - Marcelo Giannini
- Department of Restorative Dentistry, Operative Dentistry Division, University of Campinas, Piracicaba Dental School, Avenida Limeira 901, Areião, 13414-903 Piracicaba, SP, Brazil.
| |
Collapse
|
2
|
Fan-Chiang YS, Chou PC, Hsiao YW, Cheng YH, Huang Y, Chiu YC, Lin YJ, Mine Y, Feng SW, Lee IT, Peng TY. Optimizing Dental Bond Strength: Insights from Comprehensive Literature Review and Future Implications for Clinical Practice. Biomedicines 2023; 11:2995. [PMID: 38001996 PMCID: PMC10669570 DOI: 10.3390/biomedicines11112995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 10/26/2023] [Accepted: 11/06/2023] [Indexed: 11/26/2023] Open
Abstract
This review examines the modifying factors affecting bond strength in various bonding scenarios, particularly their relevance to the longevity of dental restorations. Understanding these factors is crucial for improving clinical outcomes in dentistry. Data were gathered from the PubMed database, ResearchGate, and Google Scholar resources, covering studies from 1992 to 2022. The findings suggest that for dentin-resin bonds, minimizing smear layers and utilizing MMP inhibitors to prevent hybrid layer degradation are essential. In the case of resin-resin bonds, reversing blood contamination is possible, but preventing saliva contamination is more challenging, underscoring its critical importance during clinical procedures. Additionally, while pretreatment on ceramics has minimal impact on bond strength, the influence of specific colorings should be carefully considered in treatment planning. This comprehensive review highlights that although established practices recognize significant bond strength factors, ongoing research provides valuable insights to enhance the clinical experience for patients. Once confirmed through rigorous experimentation, these emerging findings should be swiftly integrated into dental practice to improve patient outcomes.
Collapse
Affiliation(s)
- Yung-Shin Fan-Chiang
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan; (Y.-S.F.-C.); (S.-W.F.)
| | - Peng-Chen Chou
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan; (Y.-S.F.-C.); (S.-W.F.)
| | - Yu-Wen Hsiao
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan; (Y.-S.F.-C.); (S.-W.F.)
| | - Yu-Hsuan Cheng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan; (Y.-S.F.-C.); (S.-W.F.)
| | - Yi Huang
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan; (Y.-S.F.-C.); (S.-W.F.)
| | - Yu-Chieh Chiu
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan; (Y.-S.F.-C.); (S.-W.F.)
| | - Yu-Ju Lin
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan; (Y.-S.F.-C.); (S.-W.F.)
| | - Yuichi Mine
- Department of Medical Systems Engineering, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima 734-8553, Japan
- Project Research Center for Integrating Digital Dentistry, Hiroshima University, Hiroshima 734-8553, Japan
| | - Sheng-Wei Feng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan; (Y.-S.F.-C.); (S.-W.F.)
| | - I-Ta Lee
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan; (Y.-S.F.-C.); (S.-W.F.)
| | - Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan; (Y.-S.F.-C.); (S.-W.F.)
| |
Collapse
|
3
|
Karadas M, Bedir F. Does extended air-drying time improve bond strength of universal adhesives to enamel? J ESTHET RESTOR DENT 2023; 35:1113-1120. [PMID: 37039512 DOI: 10.1111/jerd.13050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 03/29/2023] [Accepted: 03/30/2023] [Indexed: 04/12/2023]
Abstract
OBJECTIVE To investigate the effect of extended air-drying time on the microshear bond strength (MSBS) of universal adhesives to enamel. MATERIALS AND METHODS The distal and mesial specimens from third molars were wet-ground and randomly assigned to three groups according to adhesives tested (n = 60): Clearfil Bond Universal, Gluma Bond Universal, and G-Premio Bond. The adhesives were applied in etch-and-rinse or self-etch modes, followed by air-drying for 5, 15, or 25 s. Composite buildups were constructed and subjected to the MSBS test after 24-h or thermocycling. MSBS results were evaluated using a four-way ANOVA. The thickness of the adhesive layer and the degree of solvent evaporation were further evaluated. RESULTS At 24-h, MSBS of G-Premio Bond significantly improved with the 25 s air-drying in both of the etching modes when compared to the 5 s air-drying. After thermocycling, the extended air-drying did not produce a significant difference on the MSBS, regardless of the application strategy. Extended air-drying (25 s) evaporated almost all of the volatile part of Gluma Bond Universal and G-Premio Bond. CONCLUSIONS Extended air-drying times increased solvent evaporation but did not contribute to the bonding effectiveness of the adhesives, regardless of the etching mode. CLINICAL SIGNIFICANCE Air-drying applications for more than 5 s had no significant effect on enamel bonding performance of universal adhesives.
Collapse
Affiliation(s)
- Muhammet Karadas
- Department of Restorative Dentistry, Recep Tayyip Erdogan University, Faculty of Dentistry, Rize, Turkey
| | - Fatih Bedir
- Department of Restorative Dentistry, Recep Tayyip Erdogan University, Faculty of Dentistry, Rize, Turkey
| |
Collapse
|
4
|
Piemjai M, Waleepitackdej O, Garcia-Godoy F. Marginal Micro-Seal and Tensile Bond Strength of a Biopolymer Hybrid Layer Coupled with Dental Prosthesis Using a Primerless-Wet System. Polymers (Basel) 2023; 15:polym15020283. [PMID: 36679164 PMCID: PMC9862600 DOI: 10.3390/polym15020283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 12/23/2022] [Accepted: 12/25/2022] [Indexed: 01/09/2023] Open
Abstract
The aim of this study is to compare the marginal seal and tensile bond strength (TBS) of prostheses fixed to enamel-dentin using different adhesive systems. Resin-composite inlays directly fabricated from Class V cavities of extracted human molars/premolars and mini-dumbbell-shaped specimens of bonded enamel-dentin were prepared for microleakage and tensile tests, respectively. Four adhesive systems were used: primerless-wet (1-1 etching for 10-, 30-, or 60-s, and 4-META/MMA-TBB), primer-moist (All-Bond2 + Duolink or Single-Bond2 + RelyX ARC), self-etch (AQ-Bond + Metafil FLO), and dry (Super-Bond C&B) bonding. Dye penetration distance and TBS data were recorded. Failure modes and characteristics of the tooth-resin interface were examined on the fractured specimens. All specimens in 10-, 30-, and 60-s etching primerless-wet, Super-Bond, and AQ-Bond had a microleakage-free tooth-resin interface. Primer-moist groups showed microleakage at the cementum/dentin-resin margin/interface. Significantly higher TBSs (p < 0.05) were recorded in primer-less-wet and Super-Bond groups with the consistent hybridized biopolymer layer after the chemical challenge and mixed failure in tooth structure, luting-resin, and at the PMMA-rod interface. There was no correlation between microleakage and TBS data (p = −0.148). A 1−3 µm hybrid layer created in the 10−60 s primerless-wet technique, producing complete micro-seal and higher tensile strength than enamel and cured 4-META/MMA-TBB, may enhance clinical performances like Super-Bond C&B, the sustainable luting resin.
Collapse
Affiliation(s)
- Morakot Piemjai
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
- Correspondence:
| | - Onusa Waleepitackdej
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
| | - Franklin Garcia-Godoy
- Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN 38163, USA
- Adjunct Faculty, The Forsyth Institute, Cambridge, MA 02142, USA
| |
Collapse
|
5
|
Degradation and Stabilization of Resin-Dentine Interfaces in Polymeric Dental Adhesives: An Updated Review. COATINGS 2022. [DOI: 10.3390/coatings12081094] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Instability of the dentine-resin interface is owed to the partial/incomplete penetration of the resin adhesives in the collagen fibrils. However, interfacial hydrolysis of the resin-matrix hybrid layer complex activates the collagenolytic and esterase enzymes that cause the degradation of the hybrid layer. Adequate hybridization is often prevented due to the water trapped between the interfibrillar spaces of the collagen network. Cyclic fatigue rupture and denaturation of the exposed collagen fibrils have been observed on repeated application of masticatory forces. To prevent interfacial microstructure, various approaches have been explored. Techniques that stabilize the resin–dentine bond have utilized endogenous proteases inhibitors, cross linking agents’ incorporation in the exposed collagen fibrils, an adhesive system free of water, and methods to increase the monomer penetration into the adhesives interface. Therefore, it is important to discover and analyze the causes of interfacial degradation and discover methods to stabilize the hybrid layer to execute new technique and materials. To achieve a predictable and durable adhesive resin, restoration is a solution to the many clinical problems arising due to microleakage, loss of integrity of the restoration, secondary caries, and postoperative sensitivity. To enhance the longevity of the resin-dentine bond strength, several experimental strategies have been carried out to improve the resistance to enzymatic degradation by inhibiting intrinsic collagenolytic activity. In addition, biomimetic remineralization research has advanced considerably to contemporary approaches of both intrafibrillar and extrafibrillar remineralization of dental hard tissues. Thus, in the presence of biomimetic analog complete remineralization of collagen, fibers are identified.
Collapse
|
6
|
Stape THS, Viita-aho T, Sezinando A, Seseogullari-Dirihan R, Eleftheriadi E, Mutluay M, Tezvergil-Mutluay A. To etch or not to etch, Part II: On the hydrophobic-rich content and fatigue strength of universal adhesives. Dent Mater 2022; 38:1419-1431. [DOI: 10.1016/j.dental.2022.06.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 06/09/2022] [Accepted: 06/22/2022] [Indexed: 11/03/2022]
|
7
|
The effect of diabetes mellitus on the shear bond strength of composite resin to dentin and enamel. Odontology 2021; 110:92-98. [PMID: 34318336 DOI: 10.1007/s10266-021-00641-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 07/13/2021] [Indexed: 10/20/2022]
Abstract
Diabetes mellitus might be linked to the deterioration of certain physical properties of dentin and enamel. This study aimed to determine the effect of two types of diabetes on the shear bond strength of enamel and dentin, by using the single bond universal bonding system. Sixty specimens [from 15 teeth; 5 from each group-non-diabetic (ND), Diabetic type I (D1), and Diabetic type II (D2)], were prepared with equal amounts of dentin (n = 5) and enamel (n = 5). Enamel specimens (E20) were etched with 37% phosphoric acid, for 20 s, and dentin specimens (D15) were etched for 15 s. A standard shear bond strength test was performed on all specimens. Their failure modes were also studied under a scanning electron microscope, and the data were analyzed by using ANOVA and Post Hoc Tukey's test (a = 0.050). For the enamel groups, significant differences were only noticed between the ND and D1 (P < 0.050) groups, and between the ND and D2 (P < 0.050) groups. In the dentin groups, there was a significant difference only between the ND and D1 (P < 0.050) groups. The micrographs showed that the ND group had the highest number of specimens with cohesive failure and D1 had the highest number of specimens with adhesive failure. It can be concluded that both types of diabetes reduce the shear bond strength of composite resin on dentin and enamel. However, it seems that the negative effect of diabetes on shear bond strength of dental composite resin is more drastic in individuals with type I diabetes as compared with type II.
Collapse
|
8
|
Bahari M, Savadi Oskoee S, Ebrahimi Chaharom ME, Molayi N. The effects of different surface contaminators on the shear bond strength of a universal adhesive system to dentin: an experimental study. J Dent Res Dent Clin Dent Prospects 2021; 15:82-86. [PMID: 34386177 PMCID: PMC8346715 DOI: 10.34172/joddd.2021.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Accepted: 08/03/2020] [Indexed: 11/28/2022] Open
Abstract
Background. Contamination of dentin surface is one of the common problems in restorative dentistry. The aim was to investigate the effects of different surface contaminators on the dentin shear bond strength (SBS) of universal adhesive system (UAS) applied in etch-and-rinse (ER) and self-etch (SE) strategies. Methods. One hundred forty-four maxillary anterior sound human teeth were divided into six groups based on the types of surface contaminators: no surface contaminator (control) and experimental groups contaminated with blood, saliva, aluminium chloride (ALC), ferric sulphate (FS), and caries disclosing agent (CDA). Then, each group was further subdivided into two, based on the application strategy of UAS (ER and SE). After applying the adhesive according to the manufacturer’s instructions, and bonding cylindrical composite samples, the SBS was measured. The data were analysed using two-way ANOVA, Tukey’s HSD test and t test (P < 0.05). Results. The SBS in all contaminated groups, except for CDA, was significantly lower in both ER and SE strategies compared to control group (P < 0.05). A comparison between the application strategies revealed that ER and SE were only significantly different in the FS contaminated group (P < 0.05). Conclusion. All tested contaminators, except CDA, significantly decreased SBS of UAS in both ER and SE strategies.
Collapse
Affiliation(s)
- Mahmoud Bahari
- Department of Operative Dentistry, Dental Faculty, Tabriz University of Medical Sciences, Tabriz, Iran.,Dental and Periodontal Research Center, Dental Faculty, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Siavash Savadi Oskoee
- Department of Operative Dentistry, Dental Faculty, Tabriz University of Medical Sciences, Tabriz, Iran.,Dental and Periodontal Research Center, Dental Faculty, Tabriz University of Medical Sciences, Tabriz, Iran
| | | | - Nasim Molayi
- Department of Operative Dentistry, Dental Faculty, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
9
|
Seitoku E, Hoshika S, Ikeda T, Abe S, Tanaka T, Sano H. Bonding Performance of a Hydrophilic Amide Monomer Containing Adhesive to Occlusal and Cervical Dentin. MATERIALS 2020; 13:ma13214727. [PMID: 33113885 PMCID: PMC7660189 DOI: 10.3390/ma13214727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Revised: 10/12/2020] [Accepted: 10/19/2020] [Indexed: 11/21/2022]
Abstract
This study aimed to evaluate the bonding performance of a new one-step self-etching adhesive system containing a novel hydrophilic amide monomer. Clearfil Universal Bond Quick (CUB) and Clearfil Megabond 2 (CMB) were used as the one-step and two-step adhesive systems, respectively. Flat dentin surfaces of human premolars were exposed using #600 SiC (silicon carbide) and bonded with the respective adhesives of each system. The teeth were sectioned to obtain beams (1 mm × 1 mm) after 24 h of water storage. The mean bond strength and standard deviations (MPa) on an occlusal surface were as follows: CUB: 45.9 ± 19.7 and CMB: 67.9 ± 25.3. The values for cervical ones were CUB: 56.0 ± 20.3 and CMB: 67.6 ± 16.0, respectively. In both conditions, the microtensile bond strength (μTBS) value was lower than that of CMB. As seen during the microscopic observation, no adhesive failure was observed after μTBS testing because CUB formed a firm and tight adhesive interface.
Collapse
Affiliation(s)
- Eri Seitoku
- Faculty of Dental Medicine, Hokkaido University, Sapporo 060-8586, Japan; (E.S.); (S.H.); (T.I.); (T.T.); (H.S.)
| | - Shuhei Hoshika
- Faculty of Dental Medicine, Hokkaido University, Sapporo 060-8586, Japan; (E.S.); (S.H.); (T.I.); (T.T.); (H.S.)
| | - Takatsumi Ikeda
- Faculty of Dental Medicine, Hokkaido University, Sapporo 060-8586, Japan; (E.S.); (S.H.); (T.I.); (T.T.); (H.S.)
| | - Shigeaki Abe
- Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki 852-8102, Japan
- Correspondence: ; Tel.: +81-95-819-7659
| | - Toru Tanaka
- Faculty of Dental Medicine, Hokkaido University, Sapporo 060-8586, Japan; (E.S.); (S.H.); (T.I.); (T.T.); (H.S.)
| | - Hidehiko Sano
- Faculty of Dental Medicine, Hokkaido University, Sapporo 060-8586, Japan; (E.S.); (S.H.); (T.I.); (T.T.); (H.S.)
| |
Collapse
|
10
|
Evaluation of Caries-Free Restorations Bonded with Various Adhesive Systems: In Vitro Study. Int J Dent 2020; 2020:5859835. [PMID: 32774375 PMCID: PMC7395994 DOI: 10.1155/2020/5859835] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 05/15/2020] [Accepted: 05/23/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose. Secondary caries originate from a leakage pathway where oral acids can penetrate faster and demineralize the tooth substrate deeper which can be visualized by dye penetration. The ability to prevent secondary caries by contemporary adhesive systems was evaluated in this study. Dye penetration distance through leakage and into the tooth substrate adjacent to Class V restorations after artificial caries exposure was compared. Materials and Methods. Previously frozen extracted human molars were used to prepare the Class V cavities at the CEJ on axial surfaces. All cavities were restored with either the resin-composite or amalgam with or without resin adhesives: dry bonding: Super-Bond D-Liner II Plus; moist bonding: All-Bond 2; and self-etch bonding: AQ Bond and Clearfil Protect Bond. Two subgroups of Super-Bond D-Liner II Plus were immersed for 14 days at 37°C either in artificial saliva (negative control) or the artificial caries solution. The other groups were soaked in the artificial caries solution. The distance of dye penetration into the adjacent enamel, cementum/dentin, and tooth-resin interfaces was measured after immersion in 0.5% basic fuchsin dye for 24 h. The tooth-resin interfacial layer was investigated using SEM. Results. No dye penetration into the tooth-resin interface was found in Super-Bond D-Liner II Plus and AQ Bond groups which demonstrated a constant hybrid layer after a chemical challenge. The leakage distance at the cementum/dentin-resin interface of All-Bond 2, Clearfil Protect Bond, and non-adhesive amalgam (positive control) groups was significantly higher than the distance of dye penetration into the adjacent demineralized root surface (p<0.05). Conclusion. Caries associated with either amalgam or resin-composite restorations can be prevented using resin adhesives which can penetrate into the intact tooth substrate to form a stable hybrid layer. With caries-free restorations, tooth vitality may be conserved lifelong.
Collapse
|
11
|
Ustun S, Ayaz EA. Effect of different cement systems and aging on the bond strength of chairside CAD-CAM ceramics. J Prosthet Dent 2020; 125:334-339. [PMID: 32122650 DOI: 10.1016/j.prosdent.2019.11.025] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Revised: 11/18/2019] [Accepted: 11/18/2019] [Indexed: 11/19/2022]
Abstract
STATEMENT OF PROBLEM The bond strength of different chairside computer-aided design and computer-aided manufacturing (CAD-CAM) restorative materials to dentin with different resin cements needs to be evaluated. PURPOSE The purpose of this in vitro study was to investigate the effect of 3 different cementation systems after thermal aging on the shear bond strength of different CAD-CAM materials. MATERIAL AND METHODS The occlusal surfaces of 63 molar teeth of similar size were removed, and 21 zirconia-reinforced lithium disilicate (Vita Suprinity-VS), 21 polymer infiltrated ceramic (Vita Enamic-VE), and 21 resin nanoceramic (GC Cerasmart-GC) rectangular specimens of 2.5 mm in thickness were obtained. The ceramics were cemented using total etch (TE), self-etch (SE), and self-adhesive (SA) cement systems. Half of the specimens were subjected to thermal aging with 5000 cycles. The shear bond strength test of all the specimens was measured. Fractured ceramic surfaces were examined by scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDX) analysis. The Shapiro-Wilk test, 3-way analysis of variance (ANOVA), and Fisher Least Significant Difference (LSD) tests were used to analyze the shear bond strength test data (α=.05). RESULTS The highest bond strength value was found in the nonthermal aged VS-TE and the lowest in the thermal aged VE-TE. Significant interaction was found between TE and SE cemented ceramics (P<.001). For specimens cemented with the SA system, significant interaction was found among ceramics with thermal aged specimens (P<.001). Thermal aging significantly decreased the mean bond strength (P<.05). CONCLUSIONS Differences in bond strength were observed in chairside CAD-CAM ceramics when cemented with TE, SE, and SA systems. Additionally, thermal aging significantly reduced the bond strength values of all the ceramic materials, regardless of the cementation procedure. Clinicians should consider these variables and choose the most suitable cementation systems for the material used.
Collapse
Affiliation(s)
- Seda Ustun
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Karadeniz Technical University, Trabzon, Turkey
| | - Elif Aydogan Ayaz
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Karadeniz Technical University, Trabzon, Turkey.
| |
Collapse
|
12
|
Nakatani H, Mine A, Matsumoto M, Tajiri Y, Hagino R, Yumitate M, Ban S, Miura J, Minamino T, Yatani H. Effectiveness of pretreatment with phosphoric acid, sodium hypochlorite and sulfinic acid sodium salt on root canal dentin resin bonding. J Prosthodont Res 2020; 64:272-280. [PMID: 31952931 DOI: 10.1016/j.jpor.2019.08.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 07/16/2019] [Accepted: 08/15/2019] [Indexed: 10/25/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the effect of pretreatment using phosphoric acid, sodium hypochlorite and sulfinic acid sodium salt on the bonding of one-step self-etching adhesives to root canal dentin. METHODS Thirty-six single-rooted sound human premolars were randomly assigned into three groups before applying the one-step self-etching adhesive. These comprised a control group with no pretreatment, an NC group that received phosphoric acid and subsequent sodium hypochlorite gel pretreatments, and an NC+AC group that received an additional treatment with sulfinic acid sodium salt following the same pretreatment applied to the NC group. Microtensile bond strength measurements, bonding interface observations by scanning electron microscopy (SEM), elemental analyses by X-ray photoelectron spectroscopy (XPS) and degree of polymerization (DOP) analyses by Raman spectroscopy were subsequently performed. RESULTS The bond strength was significantly higher in the NC+AC group than in the other two groups (Control: P=000.1 and NC: P=0.004). SEM observations showed that resin tags were present in the dentinal tubules in the NC and NC+AC groups. Compared to the control group, the adhesive resin layer had a lower DOP in the NC group, while the DOP for the NC+AC group was higher than that of the NC specimens. CONCLUSIONS Bonding to root canal dentin was improved by applying sulfinic acid sodium salt in addition to treatment with phosphoric acid followed by sodium hypochlorite. The DOP of the adhesive resin was reduced by sodium hypochlorite and subsequently restored by applying sulfinic acid sodium salt.
Collapse
Affiliation(s)
- Hayaki Nakatani
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Atsushi Mine
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan.
| | - Mariko Matsumoto
- Department of Restorative Dentistry, Hokkaido University Graduate School of Dental Medicine, Japan
| | - Yuko Tajiri
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Ryosuke Hagino
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Masahiro Yumitate
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Shintaro Ban
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Jiro Miura
- Division for Interdisciplinary Dentistry, Osaka University Dental Hospital, Japan
| | - Takuya Minamino
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Hirofumi Yatani
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| |
Collapse
|
13
|
Li M, Xu J, Zhang L, Wang C, Jin X, Hong Y, Fu B, Hannig M. Effect of a novel prime‐and‐rinse approach on short‐ and long‐term dentin bond strength of self‐etch adhesives. Eur J Oral Sci 2019; 127:547-555. [PMID: 31670441 DOI: 10.1111/eos.12660] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Mingxing Li
- Hospital of Stomatology Affiliated to Zhejiang University School of Medicine Hangzhou China
- Key Laboratory for Oral Biomedical Research of Zhejiang Province Hangzhou China
| | - Jingqiu Xu
- Hospital of Stomatology Affiliated to Zhejiang University School of Medicine Hangzhou China
- Key Laboratory for Oral Biomedical Research of Zhejiang Province Hangzhou China
| | - Ling Zhang
- Hospital of Stomatology Affiliated to Zhejiang University School of Medicine Hangzhou China
- Key Laboratory for Oral Biomedical Research of Zhejiang Province Hangzhou China
| | - Chaoyang Wang
- Hospital of Stomatology Affiliated to Zhejiang University School of Medicine Hangzhou China
- Key Laboratory for Oral Biomedical Research of Zhejiang Province Hangzhou China
| | - Xiaoting Jin
- Hospital of Stomatology Affiliated to Zhejiang University School of Medicine Hangzhou China
- Key Laboratory for Oral Biomedical Research of Zhejiang Province Hangzhou China
| | - Yan Hong
- Hospital of Stomatology Affiliated to Zhejiang University School of Medicine Hangzhou China
- Key Laboratory for Oral Biomedical Research of Zhejiang Province Hangzhou China
| | - Baiping Fu
- Hospital of Stomatology Affiliated to Zhejiang University School of Medicine Hangzhou China
- Key Laboratory for Oral Biomedical Research of Zhejiang Province Hangzhou China
| | - Matthias Hannig
- Clinic of Operative Dentistry, Periodontology and Preventive Dentistry University of Saarland Homburg Germany
| |
Collapse
|
14
|
Chowdhury AFMA, Islam R, Alam A, Matsumoto M, Yamauti M, Carvalho RM, Sano H. Variable Smear Layer and Adhesive Application: The Pursuit of Clinical Relevance in Bond Strength Testing. Int J Mol Sci 2019; 20:ijms20215381. [PMID: 31671751 PMCID: PMC6861976 DOI: 10.3390/ijms20215381] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 10/25/2019] [Accepted: 10/25/2019] [Indexed: 11/20/2022] Open
Abstract
The removal or modification of smear layers that cover the dentin is critical to allow the penetration of adhesive molecules and to ensure a strong bond between resin and dentin. Aiming to establish a model for clinically-relevant dentin-bond testing, we evaluated the effects of smear layers created by abrasives having similar coarseness (180-grit SiC paper; fine-grit diamond bur) and application modes (single application; double application) on the microtensile bond strengths (µTBS) of two currently available universal adhesives (G-Premio Bond; Scotchbond Universal Adhesive) and a two-step self-etch adhesive (Clearfil Megabond 2). Sixty extracted human third molars were used for the μTBS test. Data were analyzed by three-way ANOVA and Tukey’s test (α = 0.05). Fracture modes were determined using stereomicroscopy. An additional 24 third molars were prepared for observation of the resin–dentin interface by TEM and adhesive-smear layer interaction by SEM. μTBS was significantly affected by the adhesives and their application modes (p < 0.001), implying that the double application of universal adhesives should be recommended to improve their performance. The effect of smear layers was not significant (p > 0.05), indicating that 180-grit SiC papers could be used to prepare dentin as a substitute for fine-grit diamond burs for dentin-bond testing in laboratory settings.
Collapse
Affiliation(s)
- Abu Faem Mohammad Almas Chowdhury
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo 060-8586, Japan.
| | - Rafiqul Islam
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo 060-8586, Japan.
| | - Arefin Alam
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo 060-8586, Japan.
| | - Mariko Matsumoto
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo 060-8586, Japan.
| | - Monica Yamauti
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo 060-8586, Japan.
| | - Ricardo Marins Carvalho
- Department of Oral Biological and Medical Sciences, Division of Biomaterials, Faculty of Dentistry, University of British Columbia, 2199 Wesbrook Mall, Vancouver, BC V6T 1Z3, Canada.
| | - Hidehiko Sano
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo 060-8586, Japan.
| |
Collapse
|
15
|
Huang Z, Qi Y, Zhang K, Gu L, Guo J, Wang R, Mai S. Use of experimental-resin-based materials doped with carboxymethyl chitosan and calcium phosphate microfillers to induce biomimetic remineralization of caries-affected dentin. J Mech Behav Biomed Mater 2019; 89:81-88. [DOI: 10.1016/j.jmbbm.2018.09.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2018] [Revised: 09/03/2018] [Accepted: 09/06/2018] [Indexed: 10/28/2022]
|
16
|
SAIKAEW P, SENAWONGSE P, CHOWDHURY AFMA, SANO H, HARNIRATTISAI C. Effect of smear layer and surface roughness on resin-dentin bond strength of self-etching adhesives. Dent Mater J 2018; 37:973-980. [DOI: 10.4012/dmj.2017-349] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Pipop SAIKAEW
- Department of Operative and Endodontics, Faculty of Dentistry, Mahidol University
| | - Pisol SENAWONGSE
- Department of Operative and Endodontics, Faculty of Dentistry, Mahidol University
| | - AFM Almas CHOWDHURY
- Department of Restorative Dentistry, Division of Oral Health Science, Hokkaido University Graduate School of Dental Medicine
| | - Hidehiko SANO
- Department of Restorative Dentistry, Division of Oral Health Science, Hokkaido University Graduate School of Dental Medicine
| | | |
Collapse
|
17
|
Toledano M, Osorio R, Pérez-Álvarez MC, Osorio E, Lynch CD, Toledano-Osorio M. A zinc-doped endodontic cement facilitates functional mineralization and stress dissipation at the dentin surface. Med Oral Patol Oral Cir Bucal 2018; 23:e646-e655. [PMID: 30341273 PMCID: PMC6260998 DOI: 10.4317/medoral.22751] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Accepted: 09/07/2018] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND The purpose of this study was to evaluate nanohardness and viscoelastic behavior of dentin surfaces treated with two canal sealer cements for dentin remineralization. MATERIAL AND METHODS Dentin surfaces were subjected to: i) 37% phosphoric acid (PA) or ii) 0.5 M ethylenediaminetetraacetic acid (EDTA) conditioning prior to the application of two experimental hydroxyapatite-based cements, containing sodium hydroxide (calcypatite) or zinc oxide (oxipatite), respectively. Samples were stored in simulated body fluid during 24 h or 21 d. The intertubular and peritubular dentin were evaluated using a nanoindenter to assess nanohardness (Hi). The load/displacement responses were used for the nano-dynamic mechanical analysis to estimate complex modulus (E*) and tan delta (δ). The modulus mapping was obtained by imposing a quasistatic force setpoint to which a sinusoidal force was superimposed. AFM imaging and FESEM analysis were performed. RESULTS After 21 d of storage, dentin surfaces treated with EDTA+calcypatite, PA+calcypatite and EDTA+oxipatite showed viscoelastic discrepancies between peritubular and intertubular dentin, meaning a risk for cracking and breakdown of the surface. At both 24 h and 21 d, tan δ values at intertubular dentin treated with the four treatments performed similar. At 21 d time point, intertubular dentin treated with PA+oxipatite achieved the highest complex modulus and nanohardness, i.e., highest resistance to deformation and functional mineralization, among groups. CONCLUSIONS Intertubular and peritubular dentin treated with PA+oxipatite showed similar values of tan δ after 21 d of storage. This produced a favorable dissipation of energy with minimal energy concentration, preserving the structural integrity at the dentin surface.
Collapse
Affiliation(s)
- M Toledano
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071 - Granada - Spain,
| | | | | | | | | | | |
Collapse
|
18
|
Stape THS, Wik P, Mutluay MM, Al-Ani AAS, Tezvergil-Mutluay A. Selective dentin etching: A potential method to improve bonding effectiveness of universal adhesives. J Mech Behav Biomed Mater 2018; 86:14-22. [PMID: 29913306 DOI: 10.1016/j.jmbbm.2018.06.015] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Revised: 06/06/2018] [Accepted: 06/08/2018] [Indexed: 11/18/2022]
Abstract
OBJECTIVES To evaluate whether selective dentin etching protocols using reduced phosphoric acid (H3PO4) etching-times would affect the resin-dentin interaction of a universal adhesive to improve long-term bonding effectiveness. METHODS Mid-coronal flat dentin surfaces were produced on sound third molars, selectively etched with 32% H3PO4 for 3, 5, 10 or 15 s and bonded with a universal adhesive (Scotchbond Universal, 3 M ESPE: SU). SU in self-etch mode and a three-step etch-and-rinse adhesive were used as control groups. Bonded specimens were stored in deionized water for 24 h and sectioned into beams (cross sectional area of 0.7 mm2). Micro-tensile bond strength test (n = 6) and nanoleakage evaluation were performed immediately, after thermocycling or 6-month storage in artificial saliva. Energy dispersive X-ray analysis (n = 6) was performed to determine the residual Ca-content ratio at the hybrid layers and scanning electron microscopy (SEM) was used to observe the micromorphology of the etched dentin surfaces before and after SU application. Data were analyzed by ANOVA and Tukey test (α = 0.05). RESULTS Selective dentin etching for 3 s improved the interaction depth of the tested universal adhesive without overexposing demineralized collagen or reducing Ca-content availability at the bonded interface. The improved immediate bond strengths of the selective etching protocol remained significantly higher (p < 0.05) after long-term aging producing hybrid layers without significant differences (p > 0.05) in silver uptake levels compared to those produced on non-etched dentin. CONCLUSIONS Despite the adjunctive conclusion that universal adhesives used in self-etch mode produce superior long-term dentin bonding compared to the etch-and-rinse mode, selective etching for 3 s with conventionally used H3PO4 improves dentin bonding effectiveness; nonetheless, longer etching times should be strictly avoided.
Collapse
Affiliation(s)
- Thiago Henrique Scarabello Stape
- Department of Restorative Dentistry and Cariology, Institute of Dentistry, University of Turku, Turku, Finland; Turku University Hospital, Turku, Finland; Adhesive Dentistry Research Group, Biomaterials and Medical Device Research Programme, Biocity, Turku, Finland.
| | - Patrik Wik
- Department of Restorative Dentistry and Cariology, Institute of Dentistry, University of Turku, Turku, Finland; Turku University Hospital, Turku, Finland; Adhesive Dentistry Research Group, Biomaterials and Medical Device Research Programme, Biocity, Turku, Finland.
| | - Mustafa Murat Mutluay
- Department of Restorative Dentistry and Cariology, Institute of Dentistry, University of Turku, Turku, Finland; Department of Prosthetic Dentistry, Institute of Dentistry, University of Eastern Finland, Kuopio, Finland; Adhesive Dentistry Research Group, Biomaterials and Medical Device Research Programme, Biocity, Turku, Finland.
| | - Anas Aaqel Salim Al-Ani
- Department of Restorative Dentistry and Cariology, Institute of Dentistry, University of Turku, Turku, Finland; Turku University Hospital, Turku, Finland; Adhesive Dentistry Research Group, Biomaterials and Medical Device Research Programme, Biocity, Turku, Finland.
| | - Arzu Tezvergil-Mutluay
- Department of Restorative Dentistry and Cariology, Institute of Dentistry, University of Turku, Turku, Finland; Turku University Hospital, Turku, Finland; Adhesive Dentistry Research Group, Biomaterials and Medical Device Research Programme, Biocity, Turku, Finland.
| |
Collapse
|
19
|
Strefezza C, Amaral MM, Quinto J, Gouw-Soares SC, Zamataro CB, Zezell DM. Effect of 830 nm Diode Laser Irradiation of Root Canal on Bond Strength of Metal and Fiber Post. Photomed Laser Surg 2018; 36:439-444. [PMID: 29768091 DOI: 10.1089/pho.2017.4378] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVE AND BACKGROUND The correct selections of the cementing agent, the endodontic post material and placement protocol are critical to provide an increased longevity of the teeth that went through endodontic treatment. The irradiation with diode laser before post cementation, can promote an antimicrobial effect. However, there is a lack of information about the effect of 830 nm diode laser on the post bond strength. This study analyzed the effect of dentin root canal irradiation with high-intensity diode laser, at 830 nm, operating in continuous or pulsed mode, on the retention of metal or fiber posts, cemented with self-etching resinous composite (Panavia F) and zinc phosphate cement (ZnPO4). MATERIALS AND METHODS Human roots were irradiated with diode laser (continuous and pulsed mode). The fiber posts were luted with Panavia F and the metal posts with Panavia F or ZnPO4 cement. Specimens were sectioned into three sections (cervical, middle, and apical). The bond strength was measured by a push-out mechanical analysis. For the statistical analysis, a three-way ANOVA test was applied following a Tukey's pairwise comparison with a significance level of p = 0.05. RESULTS The irradiated groups presented higher bond strength compared with nonirradiated group (p < 0.05), and the cervical and middle thirds presented higher on bond strength than the apical. The association of metal post and Panavia F presented higher bond strength when irradiated on continuous mode (p < 0.05). Fiber post and Panavia F presented higher bond strength associated to pulsed mode. The mode seems not to make a significant difference. CONCLUSIONS These results corroborate the importance of the post bond to dentin and root canal debris removal to increase the tooth longevity. It was shown that the dentin to post bond strength were enhanced by the diode laser irradiation either on continuous or pulsed modes.
Collapse
Affiliation(s)
- Claudia Strefezza
- 1 Laboratory of Biophotonics, Center for Lasers and Applications , IPEN - CNEN/SP, São Paulo, Brazil
| | | | - José Quinto
- 1 Laboratory of Biophotonics, Center for Lasers and Applications , IPEN - CNEN/SP, São Paulo, Brazil
| | | | - Claudia Bianchi Zamataro
- 1 Laboratory of Biophotonics, Center for Lasers and Applications , IPEN - CNEN/SP, São Paulo, Brazil
| | - Denise Maria Zezell
- 1 Laboratory of Biophotonics, Center for Lasers and Applications , IPEN - CNEN/SP, São Paulo, Brazil
| |
Collapse
|
20
|
Ebrahimi M, Janani A, Majidinia S, Sadeghi R, Shirazi AS. Are self-etch adhesives reliable for primary tooth dentin? A systematic review and meta-analysis. J Conserv Dent 2018; 21:243-250. [PMID: 29899624 PMCID: PMC5977770 DOI: 10.4103/jcd.jcd_287_17] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Revised: 01/26/2018] [Accepted: 02/22/2018] [Indexed: 11/04/2022] Open
Abstract
The purpose of this study was to systematically evaluate the dentin bond strength of etch-and-rinse and self-etch adhesives to primary teeth. In this study, PubMed, ISI (all databases), Scopus, and Cochrane Database were searched according to the selected keywords up to May 11, 2016. The full texts of published articles that appeared to meet the primary criteria for inclusion in this study were obtained. Due to the variation in the methods used, the studies were divided into 2 groups: Group 1 - studies that evaluated the micro-tensile bond strengths (MTBSs) of two-step etch-and-rinse adhesives and two-step self-etch adhesives and Group 2 - studies that evaluated the MTBSs of two-step etch-and-rinse adhesives and one-step self-etch adhesives. The initial search yielded 1447 publications. After a methodological assessment, 8 publications were selected. The results of this study showed that the MTBS of the etch-and-rinse adhesives and the two-step self-etch adhesives were similar (P = 0.34), and both were significantly higher than that of the one-step self-etch adhesive (P = 0.001). This meta-analysis showed that the application of two-step self-etch adhesives performs well when used for primary dentin and can be used to save time in pediatric dentistry.
Collapse
Affiliation(s)
- Masoumeh Ebrahimi
- Department of Pediatric Dentistry, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
- Dental Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Anoosheh Janani
- Department of Pediatric Dentistry, School of Dentistry, Gilan University of Medical Sciences, Rasht, Iran
| | - Sara Majidinia
- Department of Restorative Dentistry, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
- Dental Materials Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Ramin Sadeghi
- Nuclear Medicine research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Alireza Sarraf Shirazi
- Department of Pediatric Dentistry, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
- Dental Materials Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
21
|
Influence of Polishing Methods on the Bonding Effectiveness and Durability of Different Resin Cements to Dentin. BIOMED RESEARCH INTERNATIONAL 2018; 2018:9189354. [PMID: 29682570 PMCID: PMC5851321 DOI: 10.1155/2018/9189354] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 11/14/2017] [Accepted: 12/04/2017] [Indexed: 11/25/2022]
Abstract
The purpose of this study was to investigate the impact of polishing methods on the bonding effectiveness and durability of different resin cements to dentin. The dentin surfaces were either treated with a fine-grit diamond bur (polishing A) or further polished by polishing disks (polishing B), and then they were bonded with any one of the three resin cements, namely, etch-and-rinse, self-etch, and self-adhesive resin cements. After 24-hour or 2-year water storage, a microtensile bond strength (μTBS) test was performed. A scanning electron microscope (SEM) was used to observe the morphology of the smear layer as well as the resin-dentin bonding interface. The results indicated that a thinner smear layer thickness was created by polishing B compared with polishing A. Although self-etch and self-adhesive resin cements achieved a relatively high primary bond strength before water degradation, etch-and-rinse resin cement obtained a stable bond strength during water degradation. The application of an additional polishing procedure could improve the bond strength of self-etch and self-adhesive resin cements.
Collapse
|
22
|
Toledano M, Osorio R, Osorio E, Cabello I, Toledano-Osorio M, Aguilera FS. In vitro mechanical stimulation facilitates stress dissipation and sealing ability at the conventional glass ionomer cement-dentin interface. J Dent 2018; 73:61-69. [PMID: 29653140 DOI: 10.1016/j.jdent.2018.04.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Revised: 04/06/2018] [Accepted: 04/08/2018] [Indexed: 10/17/2022] Open
Abstract
OBJECTIVE The aim of this study was to evaluate the induced changes in the chemical and mechanical performance at the glass-ionomer cement-dentin interface after mechanical load application. METHODS A conventional glass-ionomer cement (GIC) (Ketac Bond), and a resin-modified glass-ionomer cement (RMGIC) (Vitrebond Plus) were used. Bonded interfaces were stored in simulated body fluid, and then tested or submitted to the mechanical loading challenge. Different loading waveforms were applied: No cycling, 24 h cycled in sine or loaded in sustained hold waveforms. The cement-dentin interface was evaluated using a nano-dynamic mechanical analysis, estimating the complex modulus and tan δ. Atomic Force Microscopy (AFM) imaging, Raman analysis and dye assisted confocal microscopy evaluation (CLSM) were also performed. RESULTS The complex modulus was lower and tan delta was higher at interfaces promoted with the GIC if compared to the RMGIC unloaded. The conventional GIC attained evident reduction of nanoleakage. Mechanical loading favored remineralization and promoted higher complex modulus and lower tan delta values at interfaces with RMGIC, where porosity, micropermeability and nanoleakage were more abundant. CONCLUSIONS Mechanical stimuli diminished the resistance to deformation and increased the stored energy at the GIC-dentin interface. The conventional GIC induced less porosity and nanoleakage than RMGIC. The RMGIC increased nanoleakage at the porous interface, and dye sorption appeared within the cement. Both cements created amorphous and crystalline apatites at the interface depending on the type of mechanical loading. CLINICAL SIGNIFICANCE Remineralization, lower stress concentration and resistance to deformation after mechanical loading improved the sealing of the GIC-dentin interface. In vitro oral function will favor high levels of accumulated energy and permits micropermeability at the RMGIC-dentin interface which will become remineralized.
Collapse
Affiliation(s)
- Manuel Toledano
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071, Granada, Spain.
| | - Raquel Osorio
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071, Granada, Spain
| | - Estrella Osorio
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071, Granada, Spain
| | - Inmaculada Cabello
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071, Granada, Spain
| | - Manuel Toledano-Osorio
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071, Granada, Spain
| | - Fátima S Aguilera
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071, Granada, Spain
| |
Collapse
|
23
|
Thanatvarakorn O, Prasansuttiporn T, Thittaweerat S, Foxton RM, Ichinose S, Tagami J, Hosaka K, Nakajima M. Smear layer-deproteinizing improves bonding of one-step self-etch adhesives to dentin. Dent Mater 2018; 34:434-441. [DOI: 10.1016/j.dental.2017.11.023] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2017] [Revised: 10/08/2017] [Accepted: 11/24/2017] [Indexed: 11/28/2022]
|
24
|
Toledano M, Pérez-Álvarez MC, Aguilera FS, Osorio E, Cabello I, Toledano-Osorio M, Osorio R. A zinc oxide-modified hydroxyapatite-based cement facilitated new crystalline-stoichiometric and amorphous apatite precipitation on dentine. Int Endod J 2017; 50 Suppl 2:e109-e119. [DOI: 10.1111/iej.12807] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 06/23/2017] [Indexed: 11/26/2022]
Affiliation(s)
- M. Toledano
- Department of Stomatology; Dental Materials Section; Faculty of Dentistry; University of Granada; Granada Spain
| | | | - F. S. Aguilera
- Department of Stomatology; Dental Materials Section; Faculty of Dentistry; University of Granada; Granada Spain
| | - E. Osorio
- Department of Stomatology; Dental Materials Section; Faculty of Dentistry; University of Granada; Granada Spain
| | - I. Cabello
- Department of Stomatology; Dental Materials Section; Faculty of Dentistry; University of Granada; Granada Spain
| | - M. Toledano-Osorio
- Department of Stomatology; Dental Materials Section; Faculty of Dentistry; University of Granada; Granada Spain
| | - R. Osorio
- Department of Stomatology; Dental Materials Section; Faculty of Dentistry; University of Granada; Granada Spain
| |
Collapse
|
25
|
Toledano M, Osorio R, Osorio E, Cabello I, Toledano-Osorio M, Aguilera FS. A zinc chloride-doped adhesive facilitates sealing at the dentin interface: A confocal laser microscopy study. J Mech Behav Biomed Mater 2017; 74:35-42. [PMID: 28535395 DOI: 10.1016/j.jmbbm.2017.04.030] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Revised: 03/06/2017] [Accepted: 04/17/2017] [Indexed: 10/19/2022]
Abstract
The aim of this study was to ascertain the effect of Zn-doping of dental adhesives and mechanical load cycling on the micromorphology of the resin-dentin interdiffusion zone (of sound and caries affected dentin). The investigation considered two different Zn-doped adhesive approaches and evaluated the interface using a doubled dye fluorescent technique and a calcium chelator fluorophore under a confocal laser scanning microscopy. Sound and carious dentin-resin interfaces of unloaded specimens were deficiently resin-hybridized, in general. These samples showed a rhodamine B-labeled hybrid layer and adhesive layer completely affected by fluorescein penetration (nanoleakage) through the porous resin-dentin interface. It was thicker after phosphoric acid-etching and more extended in carious dentin. Zn-doping promoted an improved sealing of the resin-dentin interface, a decrease of the hybrid layer porosity, and an increment of dentin mineralization. Load cycling augmented the sealing of the Zn-doped resin-dentin interfaces, as porosity and nanoleakage diminished, and even disappeared in caries-affected dentin substrata conditioned with EDTA. Sound and carious dentin specimens analyzed with the xylenol orange technique produced a clearly outlined fluorescence when resins were Zn-doped, due to a consistent Ca-mineral deposition within the bonding interface and inside the dentinal tubules. It was more evident when load cycling was applied on specimens treated with self-etching adhesives that were Zn-doped. Micropermeability at the resin-dentin interface diminished after combining EDTA pretreatment, ZnCl2-doping and mechanical loading stimuli on restorations. It is clearly preferable to include the zinc compounds into the bonding constituents of the self-etching adhesives, instead of into the primer ingredients. The promoted new mineral segments contributed to reduce or avoid both porosity and nanoleakage from the load cycled Zn-doped resin dentin interfaces. EDTA+SB-ZnCl2 or SEB·Bd-Zn doping are preferred to treat caries-affected dentin surfaces. ZnO-doping encouraged for etch-and-rinse adhesives.
Collapse
Affiliation(s)
- Manuel Toledano
- University of Granada, Faculty of Dentistry, Dental Materials Section Colegio Máximo de Cartuja s/n, 18071 Granada, Spain.
| | - Raquel Osorio
- University of Granada, Faculty of Dentistry, Dental Materials Section Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| | - Estrella Osorio
- University of Granada, Faculty of Dentistry, Dental Materials Section Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| | - Inmaculada Cabello
- University of Granada, Faculty of Dentistry, Dental Materials Section Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| | - Manuel Toledano-Osorio
- University of Granada, Faculty of Dentistry, Dental Materials Section Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| | - Fátima S Aguilera
- University of Granada, Faculty of Dentistry, Dental Materials Section Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| |
Collapse
|
26
|
Mechanical loading influences the viscoelastic performance of the resin-carious dentin complex. Biointerphases 2017; 12:021001. [PMID: 28376622 DOI: 10.1116/1.4979633] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The aim of this study was to evaluate the changes in the mechanical behavior and bonding capability of Zn-doped resin-infiltrated caries-affected dentin interfaces. Dentin surfaces were treated with 37% phosphoric acid (PA) followed by application of a dentin adhesive, single bond (SB) (PA+SB) or by 0.5 M ethylenediaminetetraacetic acid (EDTA) followed by SB (EDTA+SB). ZnO microparticles of 10 wt. % or 2 wt. % ZnCl2 was added into SB, resulting in the following groups: PA+SB, PA+SB-ZnO, PA+SB-ZnCl2, EDTA+SB, EDTA+SB-ZnO, EDTA+SB-ZnCl2. Bonded interfaces were stored for 24 h, and tested or submitted to mechanical loading. Microtensile bond strength was assessed. Debonded surfaces were evaluated by scanning electron microscopy and elemental analysis. The hybrid layer, bottom of the hybrid layer, and peritubular and intertubular dentin were evaluated using a nanoindenter. The load/displacement responses were used for the nanodynamic mechanical analysis III to estimate complex modulus, tan delta, loss modulus, and storage modulus. The modulus mapping was obtained by imposing a quasistatic force setpoint to which a sinusoidal force was superimposed. Atomic force microscopy imaging was performed. Load cycling decreased the tan delta at the PA+SB-ZnCl2 and EDTA+SB-ZnO interfaces. Tan delta was also diminished at peritubular dentin when PA+SB-ZnO was used, hindering the dissipation of energy throughout these structures. Tan delta increased at the interface after using EDTA+SB-ZnCl2, lowering the energy for recoil or failure. After load cycling, loss moduli at the interface decreased when using ZnCl2 as doping agent, increasing the risk of fracture; but when using ZnO, loss moduli was dissimilarly affected if dentin was EDTA-treated. The border between intertubular and peritubular dentin attained the highest discrepancy in values of viscoelastic properties, meaning a risk for cracking and breakdown of the resin-dentin interface. PA used on dentin provoked differences in complex and storage modulus values at the intertubular and peritubular structures, and these differences were higher than when EDTA was employed. In these cases, the long-term performance of the restorative interface will be impaired.
Collapse
|
27
|
Abreu JLBD, Prado M, Simão RA, Silva EMD, Dias KRHC. Effect of Non-Thermal Argon Plasma on Bond Strength of a Self-Etch Adhesive System to NaOCl-Treated Dentin. Braz Dent J 2017; 27:446-51. [PMID: 27652709 DOI: 10.1590/0103-6440201600914] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Accepted: 05/20/2016] [Indexed: 11/22/2022] Open
Abstract
Studies have been showing a decrease of bond strength in dentin treated with sodium hypochlorite (NaOCl). The aim of this study was to evaluate the effect of non-thermal argon plasma on the bond strength of a self-etch adhesive system to dentin exposed to NaOCl. Thirty-two flat dentin surfaces of bovine incisors were immersed in 2.5% NaOCl for 30 min to simulate the irrigation step during endodontic treatment. The specimens were divided into four groups (n=8), according to the surface treatment: Control (without plasma treatment), AR15 (argon plasma for 15 s), AR30 (argon plasma for 30 s) and AR45 (argon plasma for 45 s). For microtensile bond strength test, 5 specimens were used per group. In each group, the specimens were hybridized with a self-etch adhesive system (Clearfil SE Bond) and resin composite buildups were constructed. After 48 h of water storage, specimens were sectioned into sticks (5 per tooth, 25 per group) and subjected to microtensile bond strength test (μTBS) until failure, evaluating failure mode. Three specimens per group were analyzed under FTIR spectroscopy to verify the chemical modifications produced in dentin. μTBS data were analyzed using ANOVA and Tamhane tests (p<0.05). AR30 showed the highest μTBS (20.86±9.0). AR15 (13.81±6.4) and AR45 (11.51±6.8) were statistically similar to control (13.67±8.1). FTIR spectroscopy showed that argon plasma treatment produced chemical modifications in dentin. In conclusion, non-thermal argon plasma treatment for 30 s produced chemical changes in dentin and improved the μTBs of Clearfil SE Bond to NaOCl-treated dentin.
Collapse
Affiliation(s)
| | - Maíra Prado
- Department of Dental Clinic, Dental School, UFRJ - Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brazil.,Department of Dental Clinic, Dental School, UFRJ - Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - Renata Antoun Simão
- Laboratory of Polymer and Asphalt Surfaces, School of Metallurgical and Materials Engineering, UFRJ - Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - Eduardo Moreira da Silva
- Analytical Laboratory of Restorative Biomaterials, Dental School, UFF - Universidade Federal Fluminense, Niterói, RJ, Brazil
| | | |
Collapse
|
28
|
Toledano M, Osorio R, Cabello I, Osorio E, Toledano-Osorio M, Aguilera FS. Oral Function Improves Interfacial Integrity and Sealing Ability Between Conventional Glass Ionomer Cements and Dentin. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2017; 23:131-144. [PMID: 28148310 DOI: 10.1017/s1431927617000010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The aim of this study was to investigate if load cycling affects interfacial integrity of glass ionomer cements bonded to sound- or caries-affected dentin. A conventional glass ionomer, Ketac Bond, and a resin-modified glass ionomer (Vitrebond Plus), were applied to dentin. Half of the specimens were load cycled. The interfaces were submitted to dye-assisted confocal microscopy evaluation. The unloaded specimens of sound and carious dentin were deficiently hybridized when Ketac Bond was used. Ketac Bond samples showed an absorption layer and an adhesive layer that were scarcely affected by fluorescein penetration (nanoleakage), in sound dentin. Nevertheless, a higher degree of micropermeability was found in carious dentin. In Ketac Bond specimens, load cycling improves the sealing capability and remineralization at the cement-dentin interface as porosity and nanoleakage was reduced. In contrast, samples treated with Vitrebond Plus exhibited a Rhodamine B-labeled absorption layer with scarce nanoleakage in both sound and carious unloaded dentin. The adhesive layer was affected by dye sorption throughout the porous cement-dentin interface. Samples treated with Vitrebond Plus had significant increases in nanoleakage and cement-dye sorption after load cycling. Within the limitations of an in vitro study, it is expected that conventional glass ionomers will provide major clinical efficacy when applied to carious-affected or sound dentin.
Collapse
Affiliation(s)
- Manuel Toledano
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Raquel Osorio
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Inmaculada Cabello
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Estrella Osorio
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Manuel Toledano-Osorio
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Fátima S Aguilera
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| |
Collapse
|
29
|
Toledano M, Osorio R, Osorio E, García-Godoy F, Toledano-Osorio M, Aguilera FS. Advanced zinc-doped adhesives for high performance at the resin-carious dentin interface. J Mech Behav Biomed Mater 2016; 62:247-267. [DOI: 10.1016/j.jmbbm.2016.05.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2016] [Revised: 05/04/2016] [Accepted: 05/09/2016] [Indexed: 01/22/2023]
|
30
|
Cross-linked dry bonding: A new etch-and-rinse technique. Dent Mater 2016; 32:1124-32. [PMID: 27431091 DOI: 10.1016/j.dental.2016.06.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2015] [Revised: 03/16/2016] [Accepted: 06/22/2016] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To determine if acid-etched, cross-linked dentin can be dehydrated without lowering bond strength below that of cross-linked wet-bonded dentin in vitro. METHODS Using extracted human third molars, control acid-etched dentin was bonded with Single Bond Plus, using either the wet- or dry-bonding technique. Experimental acid-etched dentin was treated with 5mass% grape seed extract (GSE) in different solvents for 1min before undergoing wet vs dry resin-dentin bonding with Single Bond Plus. Completely demineralized dentin beams were treated with 5% GSE for 0, 1 or 10min, before measuring stiffness by 3-point flexure. Other completely demineralized beams were treated similarly and then incubated in buffer for 1 week to measure the collagen solubilization by endogenous dentin proteases. RESULTS 24h microtensile bond strengths (μTBS) in wet and dry controls were 53.5±3.6 and 9.4±1.8MPa, respectively (p<0.05). 5% GSE in water gave μTBS of 53.7±3.4 and 39.1±9.7MPa (p<0.05), respectively, while 5% GSE in ethanol gave μTBS of 51.2±2.3 and 35.3±2.0MPa (p<0.05). 5% GSE in 5% EtOH/95% water gave wet and dry μTBS of 53.0±2.3 and 55.7±5.1MPa (p>0.05). Cross-linking demineralized dentin with 5% GSE increased stiffness of dentin and decreased collagen degradation (p<0.05). SIGNIFICANCE 5% GSE pretreatment of acid-etched dentin for 1min permits the dentin to be completely air-dried without lowering bond strength.
Collapse
|
31
|
Sekhri S, Mittal S, Garg S. Tensile Bond Strength of Self Adhesive Resin Cement After Various Surface Treatment of Enamel. J Clin Diagn Res 2016; 10:ZC01-4. [PMID: 26894165 DOI: 10.7860/jcdr/2016/13409.7026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2015] [Accepted: 10/15/2015] [Indexed: 11/24/2022]
Abstract
INTRODUCTION In self adhesive resin cements adhesion is achieved to dental surface without surface pre-treatment, and requires only single step application. This makes the luting procedure less technique-sensitive and decreases postoperative sensitivity. AIM The purpose of this study was to evaluate bond strength of self adhesive resin after surface treatment of enamel for bonding base metal alloy. MATERIALS AND METHODS On the labial surface of 64 central incisor rectangular base metal block of dimension 6 mm length, 5mm width and 1 mm height was cemented with RelyX U200 and Maxcem Elite self adhesive cements with and without surface treatment of enamel. Surface treatment of enamel was application of etchant, one step bonding agent and both. Tensile bond strength of specimen was measured with universal testing machine at a cross head speed of 1mm/min. RESULTS Least tensile bond strength (MPa) was in control group i.e. 1.33 (0.32) & 1.59 (0.299), Highest bond strength observed when enamel treated with both etchant and bonding agent i.e. 2.72 (0.43) & 2.97 (0.19) for Relyx U200 and Elite cement. When alone etchant and bonding agent were applied alone bond strength is 2.19 (0.18) & 2.24 (0.47) for Relyx U200, and 2.38 (0.27) 2.49 (0.16) for Max-cem elite. Mean bond strength was higher in case of Max-cem Elite as compared to RelyX U200 resin cement, although differences were non-significant (p > 0.05). CONCLUSION Surface treatment of enamel increases the bond strength of self adhesive resin cement.
Collapse
Affiliation(s)
- Sahil Sekhri
- PG Student, Department of Prosthodontics, Maharishi Markandey College of Dental Sciences and Research , Ambala, Haryana, India
| | - Sanjeev Mittal
- Professor, Department of Prosthodontics, Maharishi Markandey College of Dental sciences and Research , Ambala, Haryana, India
| | - Sandeep Garg
- Professor and Head, Department of Prosthodontics, Maharishi Markandey College of Dental Sciences and Research , Ambala, Haryana, India
| |
Collapse
|
32
|
Toledano M, Cabello I, Aguilera FS, Osorio E, Toledano-Osorio M, Osorio R. Improved Sealing and Remineralization at the Resin-Dentin Interface After Phosphoric Acid Etching and Load Cycling. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2015; 21:1530-1548. [PMID: 26471836 DOI: 10.1017/s1431927615015317] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The purpose of this study was to investigate micro-morphology of the resin-dentin inter-diffusion zone using two different single-bottle self-etching dentin adhesives with and without previous acid-etching, after in vitro mechanical loading stimuli. Extracted human third molars were sectioned to obtain dentin surfaces. Two different single-bottle self-etching dentin adhesives, Futurabond U and Experimental both from VOCO, were applied following the manufacturer's instructions or after 37% phosphoric acid application. Resin-dentin interfaces were analyzed with dye assisted confocal microscopy evaluation (CLSM), including the calcium-chelation technique, xylenol orange (CLSM-XO). CLSM revealed that resin-dentin interfaces of unloaded specimens were deficiently resin-hybridized, in general. These samples showed a Rhodamine B-labeled hybrid complex and adhesive layer completely affected by fluorescein penetration (nanoleakage) through the porous resin-dentin interface, but thicker after PA-etching. Load cycling promoted an improved sealing of the resin-dentin interface at dentin, a decrease of the hybrid complex porosity, and an increment of dentin mineralization. Load cycled specimens treated with the XO technique produced a clearly outlined fluorescence due to consistent Ca-mineral deposits within the bonding interface and inside the dentinal tubules, especially when the experimental adhesive was applied.
Collapse
Affiliation(s)
- Manuel Toledano
- Faculty of Dentistry,University of Granada,Dental Materials Section,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Inmaculada Cabello
- Faculty of Dentistry,University of Granada,Dental Materials Section,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Fátima S Aguilera
- Faculty of Dentistry,University of Granada,Dental Materials Section,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Estrella Osorio
- Faculty of Dentistry,University of Granada,Dental Materials Section,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Manuel Toledano-Osorio
- Faculty of Dentistry,University of Granada,Dental Materials Section,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Raquel Osorio
- Faculty of Dentistry,University of Granada,Dental Materials Section,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| |
Collapse
|
33
|
Direct Tensile Strength and Characteristics of Dentin Restored with All-Ceramic, Resin-Composite, and Cast Metal Prostheses Cemented with Resin Adhesives. BIOMED RESEARCH INTERNATIONAL 2015; 2015:656948. [PMID: 26539520 PMCID: PMC4619853 DOI: 10.1155/2015/656948] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2014] [Accepted: 12/12/2014] [Indexed: 11/17/2022]
Abstract
A dentin-cement-prosthesis complex restored with either all-porcelain, cured resin-composite, or cast base metal alloy and cemented with either of the different resin cements was trimmed into a mini-dumbbell shape for tensile testing. The fractured surfaces and characterization of the dentin-cement interface of bonded specimens were investigated using a Scanning Electron Microscope. A significantly higher tensile strength of all-porcelain (12.5 ± 2.2 MPa) than that of cast metal (9.2 ± 3.5 MPa) restorations was revealed with cohesive failure in the cement and failure at the prosthesis-cement interface in Super-Bond C&B group. No significant difference in tensile strength was found among the types of restorations using the other three cements with adhesive failure on the dentin side and cohesive failure in the cured resin. SEM micrographs demonstrated the consistent hybridized dentin in Super-Bond C&B specimens that could resist degradation when immersed in hydrochloric acid followed by NaOCl solutions whereas a detached and degraded interfacial layer was found for the other cements. The results suggest that when complete hybridization of resin into dentin occurs tensile strength at the dentin-cement is higher than at the cement-prosthesis interfaces. The impermeable hybridized dentin can protect the underlying dentin and pulp from acid demineralization, even if detachment of the prosthesis has occurred.
Collapse
|
34
|
Effect of EDTA Conditioning and Carbodiimide Pretreatment on the Bonding Performance of All-in-One Self-Etch Adhesives. Int J Dent 2015; 2015:141890. [PMID: 26557850 PMCID: PMC4629033 DOI: 10.1155/2015/141890] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2015] [Revised: 09/26/2015] [Accepted: 09/29/2015] [Indexed: 11/17/2022] Open
Abstract
Objective. This study evaluated the effect of ethylenediaminetetraacetic acid (EDTA) conditioning and carbodiimide (EDC) pretreatment on the shear bond strength of two all-in-one self-etch adhesives to dentin. Methods. Flat coronal dentin surfaces were prepared on one hundred and sixty extracted human molars. Teeth were randomly divided into eight groups according to two different self-etch adhesives used [G-Bond and OptiBond-All-In-One] and four different surface pretreatments: (a) adhesive applied following manufacturer's instructions; (b) dentin conditioning with 24% EDTA gel prior to application of adhesive; (c) EDC pretreatment followed by application of adhesive; (d) application of EDC on EDTA conditioned dentin surface followed by application of adhesive. Composite restorations were placed in all the samples. Ten samples from each group were subjected to immediate and delayed (6-month storage in artificial saliva) shear bond strength evaluation. Data collected was subjected to statistical analysis using three-way ANOVA and post hoc Tukey's test at a significance level of p < 0.05. Results and Conclusion. EDTA preconditioning as well as EDC pretreatment alone had no significant effect on the immediate and delayed bond strengths of either of the adhesives. However, EDC pretreatment on EDTA conditioned dentin surface resulted in preservation of resin-dentin bond strength of both adhesives with no significant fall over six months.
Collapse
|
35
|
Mallick R, Sarangi P, Mohanty S, Behera S, Nanda S, Satapathy SK. Micro-tensile bond strength of different adhesive systems on sound dentin and resin-based composite: An in-vitro study. J Conserv Dent 2015; 18:379-83. [PMID: 26430301 PMCID: PMC4578182 DOI: 10.4103/0972-0707.164036] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Aim: To analyze the difference in the micro-tensile bond strength of specimens made with two different adhesive systems and compare them with two homogenous substrates. Materials and Methods: Sixty permanent mandibular molars were mounted in acrylic blocks and sectioned with exposed dentin surfaces. Samples were then divided into four groups. To Group-I Adper Single Bond 2 and to Group-II Adper Self-Etch plus bonding agents were applied. For Group-I and Group-II beams consisted of resin composite in the upper half and dentin in the lower half. In Group-III beams were made of only dentin. In Group-IV beams were made of only composite. Fifteen specimens of each group were taken for the micro-tensile bond strength test. Statistical Analysis: The results are analyzed using one-way analysis of variance and Critical Difference test. Results: The interface bonded with the two adhesive systems had lower micro-tensile bond strength than those of dentin and resin composite and the self-etching adhesive Adper Self-Etch plus had comparable bond strength with total-etch adhesive Adper Single Bond 2. Conclusion: The bond strength values for current adhesive systems cannot be compared to the micro-tensile bond strength of dentin and resin composite, and self-etching adhesives have comparable bond strength with total-etch adhesives.
Collapse
Affiliation(s)
- Rashmirekha Mallick
- Department of Conservative Dentistry and Endodontics, SCB Dental College and Hospital, Cuttack, Odisha, India
| | - Priyanka Sarangi
- Department of Conservative Dentistry and Endodontics, SCB Dental College and Hospital, Cuttack, Odisha, India
| | - Sandhyarani Mohanty
- Department of Conservative Dentistry and Endodontics, SCB Dental College and Hospital, Cuttack, Odisha, India
| | - Subasish Behera
- Department of Conservative Dentistry and Endodontics, SCB Dental College and Hospital, Cuttack, Odisha, India
| | - Soumyaranjan Nanda
- Department of Conservative Dentistry and Endodontics, SCB Dental College and Hospital, Cuttack, Odisha, India
| | | |
Collapse
|
36
|
Toledano M, Aguilera FS, Osorio E, Cabello I, Toledano-Osorio M, Osorio R. Functional and molecular structural analysis of dentine interfaces promoted by a Zn-doped self-etching adhesive and an in vitro load cycling model. J Mech Behav Biomed Mater 2015; 50:131-49. [DOI: 10.1016/j.jmbbm.2015.05.026] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Revised: 05/20/2015] [Accepted: 05/22/2015] [Indexed: 01/22/2023]
|
37
|
Nanoscopic dynamic mechanical analysis of resin-infiltrated dentine, under in vitro chewing and bruxism events. J Mech Behav Biomed Mater 2015; 54:33-47. [PMID: 26414515 DOI: 10.1016/j.jmbbm.2015.09.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Revised: 09/01/2015] [Accepted: 09/04/2015] [Indexed: 11/23/2022]
Abstract
The aim of this study was to evaluate the induced changes in mechanical behavior and bonding capability of resin-infiltrated dentine interfaces, after application of mechanical stimuli. Dentine surfaces were subjected to partial demineralization through 37% phosphoric acid etching followed by the application of an etch-and-rinse dentine adhesive, Single Bond (3M/ESPE). Bonded interfaces were stored in simulated body fluid during 24h, and then tested or submitted to the mechanical loading challenge. Different loading waveforms were applied: No cycling (I), 24h cycled in sine (II) or square (III) waves, sustained loading held for 24h (IV) or sustained loading held for 72h (V). Microtensile bond strength (MTBS) was assessed for the different groups. Debonded dentine surfaces were studied by field emission scanning electron microscopy (FESEM). At the resin-dentine interface, both the hybrid layer (HL) and the bottom of the hybrid layer (BHL), and both peritubular and intertubular were evaluated using a nanoindenter in scanning mode. The load and displacement responses were used to perform the nano-Dynamic Mechanical analysis and to estimate the complex and storage modulus. Dye assisted Confocal Microscopy Evaluation was used to assess sealing ability. Load cycling increased the percentage of adhesive failures in all groups. Specimens load cycled in held 24h attained the highest complex and storage moduli at HL and BHL. The storage modulus was maximum in specimens load cycled in held 24h at peritubular dentine, and the lowest values were attained at intertubular dentine. The storage modulus increased in all mechanical tests, at peritubular dentine. An absence of micropermeability and nanoleakage after loading in sine and square waveforms were encountered. Porosity of the resin-dentine interface was observed when specimens were load cycled in held 72h. Areas of combined sealing and permeability were discovered at the interface of specimens load cycled in held 24h. Crack-bridging images appeared in samples load cycled with sine waveform, after FESEM examination.
Collapse
|
38
|
Self-etching zinc-doped adhesives improve the potential of caries-affected dentin to be functionally remineralized. Biointerphases 2015; 10:031002. [DOI: 10.1116/1.4926442] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
39
|
Pinna R, Maioli M, Eramo S, Mura I, Milia E. Carious affected dentine: its behaviour in adhesive bonding. Aust Dent J 2015; 60:276-93. [DOI: 10.1111/adj.12309] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/14/2015] [Indexed: 01/31/2023]
Affiliation(s)
- R Pinna
- Department of Biomedical Science; University of Sassari; Sassari Italy
| | - M Maioli
- Department of Biomedical Science; University of Sassari; Sassari Italy
- National Institute of Biostructures and Biosystems; Italy
| | - S Eramo
- Department of Surgery and Biomedical Science; University of Perugia; Perugia Italy
| | - I Mura
- Department of Biomedical Science; University of Sassari; Sassari Italy
| | - E Milia
- Department of Biomedical Science; University of Sassari; Sassari Italy
| |
Collapse
|
40
|
Al Baker AMA, El Araby A, Al Amri MD, Sukumaran A. The Impact of Expasyl® Gingival Retraction Paste on the Bond Strength of Self-etch and Total-etch Systems. J Contemp Dent Pract 2015; 16:335-339. [PMID: 26162250 DOI: 10.5005/jp-journals-10024-1686] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
OBJECTIVE To evaluate the influence of Expasyl® gingival retraction paste on the shear bond strength of self-etch and total-etch adhesive systems. MATERIALS AND METHODS Twenty-four specimens of extracted, caries-free, sound human molars were used in this study. The molars were then cut vertically into halves through the buccal and lingual cusps. Forty-eight specimens were divided into four groups (total-etch, total-etch with Expasyl application, self-etch, self-etch with Expasyl application) and the shear bond strength was tested. RESULTS Expasyl significantly reduced the shear bond strength of the self-etch and total-etch adhesive systems. The self-etch system showed relatively lower performance compared with the total-etch adhesive system. The shear bond strength values of the total-etch adhesive without Expasyl showed the highest bond strength (21.48 ± 2.89), while the self-etching group adhesive treated with Expasyl showed the lowest shear bond strength value (14.89 ± 1.81). CONCLUSION From the observations of this in vitro study, it can be concluded that the use of Expasyl® gingival retraction system can negatively affect bond strength of adhesives. The total-etch system showed better compatibility to the Expasyl gingival retraction system than the self-etch.
Collapse
Affiliation(s)
- Abdulaziz M A Al Baker
- Associate Professor, Department of Prosthetic Dental Sciences College of Dentistry, King Saud University, Post Box: 60169 Riyadh-11545, Saudi Arabia, Fax: +9661-467-9017, e-mail:
| | - Alaa El Araby
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Mohammad D Al Amri
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Anil Sukumaran
- Department of Periodontics and Community Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
41
|
Halloysite nanotube incorporation into adhesive systems—effect on bond strength to human dentin. Clin Oral Investig 2015; 19:1905-12. [DOI: 10.1007/s00784-015-1413-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2014] [Accepted: 01/21/2015] [Indexed: 11/26/2022]
|
42
|
Toledano M, Aguilera FS, Osorio E, Cabello I, Toledano-Osorio M, Osorio R. Bond strength and bioactivity of Zn-doped dental adhesives promoted by load cycling. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2015; 21:214-230. [PMID: 25499741 DOI: 10.1017/s1431927614013658] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The purpose of this study was to evaluate if mechanical loading influences bioactivity and bond strength at the resin-dentin interface after bonding with Zn-doped etch-and-rinse adhesives. Dentin surfaces were subjected to demineralization by 37% phosphoric acid (PA) or 0.5 M ethylenediaminetetraacetic acid (EDTA). Single bond (SB) adhesive—3M ESPE—SB+ZnO particles 20 wt% and SB+ZnCl2 2 wt% were applied on treated dentin to create the groups PA+SB, SB+ZnO, SB+ZnCl2, EDTA+SB, EDTA+ZnO, and EDTA+ZnCl2. Bonded interfaces were stored in simulated body fluid for 24 h and tested or submitted to mechanical loading. Microtensile bond strength (MTBS) was assessed. Debonded dentin surfaces were studied by high-resolution scanning electron microscopy. Remineralization of the bonded interfaces was assessed by atomic force microscope imaging/nanoindentation, Raman spectroscopy/cluster analysis, and Masson's trichrome staining. Load cycling (LC) produced reduction in MTBS in all PA+SB, and no change was encountered in EDTA+SB specimens, regardless of zinc doping. LC increased the mineralization and crystallographic maturity at the interface; a higher effect was noticed when using ZnO. Trichrome staining reflected a narrow demineralized dentin matrix after loading of dentin surfaces that were treated with SB-doped adhesives. This correlates with an increase in mineral platforms or plate-like multilayered crystals in PA or EDTA-treated dentin surfaces, respectively.
Collapse
Affiliation(s)
- Manuel Toledano
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Fátima S Aguilera
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Estrella Osorio
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Inmaculada Cabello
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Manuel Toledano-Osorio
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Raquel Osorio
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| |
Collapse
|
43
|
Toledano M, Cabello I, Aguilera FS, Osorio E, Osorio R. Effect of in vitro chewing and bruxism events on remineralization, at the resin-dentin interface. J Biomech 2014; 48:14-21. [PMID: 25443879 DOI: 10.1016/j.jbiomech.2014.11.014] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Revised: 11/07/2014] [Accepted: 11/11/2014] [Indexed: 12/11/2022]
Abstract
The purpose of this study was to evaluate if different in vitro functional and parafunctional habits promote mineralization at the resin-dentin interface after bonding with three different adhesive approaches. Dentin surfaces were subjected to distinct treatments: demineralization by (1) 37% phosphoric acid (PA) followed by application of an etch-and-rinse dentin adhesive, Single Bond (SB) (PA+SB); (2) 0.5 M ethylenediaminetetraacetic acid (EDTA) followed by SB (EDTA+SB); (3) application of a self-etch dentin adhesive, Clearfil SE Bond (SEB). Different loading waveforms were applied: No cycling (I), cycled in sine (II) or square (III) waves, sustained loading hold for 24 h (IV) or sustained loading hold for 72 h (V). Remineralization at the bonded interfaces was assessed by AFM imaging/nano-indentation, Raman spectroscopy and Masson's trichrome staining. In general, in vitro chewing and parafunctional habits, promoted an increase of nano-mechanical properties at the resin-dentin interface. Raman spectroscopy through cluster analysis demonstrated an augmentation of the mineral-matrix ratio in loaded specimens. Trichrome staining reflected a narrow demineralized dentin matrix after loading in all groups except in PA+SB and EDTA+SB samples after sustained loading hold for 72 h, which exhibited a strong degree of mineralization. In vitro mechanical loading, produced during chewing and bruxism (square or hold 24 and 72 h waveforms), induced remineralization at the resin-dentin bonded interface.
Collapse
Affiliation(s)
- Manuel Toledano
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain.
| | - Inmaculada Cabello
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| | - Fátima S Aguilera
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| | - Estrella Osorio
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| | - Raquel Osorio
- University of Granada, Faculty of Dentistry, Dental Materials Section, Colegio Máximo de Cartuja s/n, 18071 Granada, Spain
| |
Collapse
|
44
|
Toledano M, Aguilera FS, Cabello I, Osorio R. Masticatory function induced changes, at subnanostructural level, in proteins and mineral at the resin-dentine interface. J Mech Behav Biomed Mater 2014; 39:197-209. [PMID: 25146674 DOI: 10.1016/j.jmbbm.2014.07.025] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2014] [Revised: 07/23/2014] [Accepted: 07/27/2014] [Indexed: 01/22/2023]
Abstract
OBJECTIVE This study evaluated the ability of different in vitro mechanical loading tests to promote new mineral formation at the bonded dentine interfaces created with a two-step self-etching resin adhesive. METHODOLOGY Restored teeth were divided in the following groups: (1) unloaded, load cycling with (2) sine waveform, (3) square waveform, and hold waveform for (4) 24h, and (5) 72 h. Raman spectroscopy and cluster analysis were used to assess the resin-dentine interface. RESULTS Mechanical loading in CSEB-treated samples promoted a generalized increase of relative presence of minerals and ratio of phosphate peaks, except in square waveform, where the nature of collagen resulted damaged. Crystallinity of carbonate was higher than phosphate. The organic component showed, in general terms, an increase in crosslinking. Molecular orientation (α-helices) peaks augmented in all tests. Pentosidine vibration increases in all tests, except in hold 72 h. Ratios amide I and II/CH2 incremented, in general. Non uniform parameters of Bis-GMA and adhesive penetration were encountered, as both increased at the bottom of the hybrid layer when loading square and hold 72 h were applied. SIGNIFICANCE Functional remineralisation at the resin-dentine interface was attained after in vitro mechanical stimuli application. When loading in square waveform, the lowest vibrations to favor remineralisation were attained.
Collapse
Affiliation(s)
- Manuel Toledano
- University of Granada, Faculty of Dentistry, Dental Materials Section Colegio Máximo de Cartuja s/n 18071, Granada, Spain.
| | - Fátima S Aguilera
- University of Granada, Faculty of Dentistry, Dental Materials Section Colegio Máximo de Cartuja s/n 18071, Granada, Spain
| | - Inmaculada Cabello
- University of Granada, Faculty of Dentistry, Dental Materials Section Colegio Máximo de Cartuja s/n 18071, Granada, Spain
| | - Raquel Osorio
- University of Granada, Faculty of Dentistry, Dental Materials Section Colegio Máximo de Cartuja s/n 18071, Granada, Spain
| |
Collapse
|
45
|
Sirisha K, Rambabu T, Shankar YR, Ravikumar P. Validity of bond strength tests: A critical review: Part I. J Conserv Dent 2014; 17:305-11. [PMID: 25125840 PMCID: PMC4127686 DOI: 10.4103/0972-0707.136340] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2014] [Revised: 03/20/2014] [Accepted: 05/04/2014] [Indexed: 11/04/2022] Open
Abstract
Adhesive systems are selected based on their bond strengths achieved while testing in laboratories. These bond strengths can predict the longevity of a restoration to some extent. There were several discrepancies in the reported bond strengths. To critically review the reliability of macro-bond strength tests used to evaluate resin-tooth interface. Relevant literature published between January 1983 and May 2013 was collected from PubMed database, Google scholar, and hand-searched journals of Conservative Dentistry, Endodontics and Dental materials. Variables that influence the test outcome are categorized into substrate-related factors, factors related to specimen properties, preparation of specimens, and test methodology. Impact of these variables on the test outcome is critically analyzed. There is lack of a standard format for reporting the bond strength tests, which could lead to misinterpretation of the data and bonding abilities of adhesives.
Collapse
Affiliation(s)
- Kantheti Sirisha
- Department of Conservative Dentistry and Endodontics, GITAM Dental College and Hospital, Visakhapatnam, Andhra Pradesh, India
| | - Tankonda Rambabu
- Departments of Conservative Dentistry and Endodontics, Vishnu Dental College and Hospital, Bhimavaram, Andhra Pradesh, India
| | - Yalavarthi Ravi Shankar
- Department of Prosthodontics, GITAM Dental College and Hospital, Visakhapatnam, Andhra Pradesh, India
| | - Pabbati Ravikumar
- Department of Conservative Dentistry and Endodontics, SIBAR Institute of Dental Sciences, Guntur, Andhra Pradesh, India
| |
Collapse
|
46
|
Toledano M, Aguilera FS, Osorio E, Cabello I, Osorio R. Microanalysis of thermal-induced changes at the resin-dentin interface. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2014; 20:1218-1233. [PMID: 24905087 DOI: 10.1017/s1431927614000944] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The purpose of this study was to evaluate the ability of two dentin adhesive systems to induce remineralization in the bonded dentin interface after in vitro thermo-cycling. Dentin surfaces were treated with two different adhesive approaches: (1) 37% phosphoric acid (PA) plus an "etch-and-rinse" dentin adhesive (single bond, SB) (PA+SB) or (2) application of a "self-etch" dentin adhesive (Clearfil SE bond, SEB). Three groups were established: (i) 24 h or (ii) 3 m storage, and (iii) specimens submitted to thermal cycling (100,000 cy/5 and 55ºC). Atomic force microscopy imaging/nanoindentation, Raman spectroscopy/cluster analysis with dye-assisted confocal laser scanning microscopy (CLSM) evaluation and Masson's trichrome staining assessments were implemented for characterization. Thermo-cycling increased nanohardness in PA+SB at the hybrid layer (HL) and in SEB at the bottom of the HL (BHL). Young's modulus increased at both the HL and BHL in SEB and at the HL in PA+SB, after thermal stress. Cluster analysis demonstrated an augmentation of the mineral-matrix ratio in thermo-cycled specimens. CLSM showed a decrease of both micropermeability and nanoleakage after thermo-cycling in PA+SB, and were completely absent in SEB. Trichrome staining reflected a scarce demineralized front in PA+SB after thermo-cycling and total remineralization in SEB.
Collapse
Affiliation(s)
- Manuel Toledano
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Fátima S Aguilera
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Estrella Osorio
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Inmaculada Cabello
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| | - Raquel Osorio
- Faculty of Dentistry,Dental Materials Section,University of Granada,Colegio Máximo de Cartuja s/n,18071 Granada,Spain
| |
Collapse
|
47
|
Lin J, Zheng WY, Liu PRF, Zhang N, Lin HP, Fan YJ, Gu XH, Vollrath O, Mehl C. Influence of casein phosphopeptide-amorphous calcium phosphate application, smear layer removal, and storage time on resin-dentin bonding. J Zhejiang Univ Sci B 2014; 15:649-60. [PMID: 25001224 DOI: 10.1631/jzus.b1300216] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The aim of this study is to evaluate the influence of Tooth Mousse (TM) application, smear layer removal, and storage time on resin-dentin microtensile bond strength (µTBS). Dentin specimens were divided into two groups: (1) smear layer covered; (2) smear layer removed using 15% EDTA for 90 s. In each group, half the specimens were treated once with TM for 60 min. After bonding procedures using a two-step self-etching adhesive (Clearfil SE Bond (CSE); Kuraray Medical, Tokyo, Japan), an all-in-one adhesive (G-Bond (GB); GC Corp, Tokyo, Japan), and a total-etch adhesive (Adper Single Bond 2 (SB); 3M ESPE, St. Paul, MN, USA), the specimens were stored for 3 d or 6 months in deionized water at 37 °C, and µTBS was tested and analyzed. With the exception of SB (no TM application) and GB, the μTBS was significantly increased for CSE and SB using EDTA pre-conditioning and 3 d of storage (P≤0.001). Bond strength of GB decreased significantly when using EDTA (3 d storage, P<0.05). TM application only increased the μTBS of GB (no EDTA) and SB (with EDTA) after 3 d (P≤0.02). Comparing the adhesives after 3 d of storage, CSE exhibited the greatest μTBS values followed by GB and SB (P≤0.02). The factors of adhesive, EDTA, and TM did not show any significant impact on μTBS when specimens were stored for 6 months (P>0.05). The additional application of TM and EDTA for cavity preparation seems only to have a short-term effect, and no influence on µTBS of dentin bonds after a period of 6 months.
Collapse
Affiliation(s)
- Jun Lin
- Department of Stomatology, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310003, China; Institute of Medical Informatics and Statistics, University Hospital Schleswig-Holstein, Campus Kiel, 24105 Kiel, Germany; Department of Prosthodontics, Propaedeutics and Dental Materials, Christian-Albrechts University at Kiel, Arnold-Heller-Straße 16, 24105 Kiel, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Taschner M, Kümmerling M, Lohbauer U, Breschi L, Petschelt A, Frankenberger R. Effect of Double-layer Application on Dentin Bond Durability of One-step Self-etch Adhesives. Oper Dent 2014; 39:416-26. [DOI: 10.2341/13-168-l] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Purpose
The aim of this in vitro study was 1) to analyze the influence of a double-layer application technique of four one-step self-etch adhesive systems on dentin and 2) to determine its effect on the stability of the adhesive interfaces stored under different conditions.
Materials and Methods
Four different one-step self-etch adhesives were selected for the study (iBondSE, Clearfil S3 Bond, XenoV+, and Scotchbond Universal). Adhesives were applied according to manufacturers' instructions or with a double-layer application technique (without light curing of the first layer). After bonding, resin-dentin specimens were sectioned for microtensile bond strength testing in accordance with the nontrimming technique and divided into 3 subgroups of storage: a) 24 hours (immediate bond strength, T0), b) six months (T6) in artificial saliva at 37°C, or c) five hours in 10 % NaOCl at room temperature. After storage, specimens were stressed to failure. Fracture mode was assessed under a light microscope.
Results
At T0, iBond SE showed a significant increase in microtensile bond strength when the double-application technique was applied. All adhesive systems showed reduced bond strengths after six months of storage in artificial saliva and after storage in 10% NaOCl for five hours; however at T6, iBond SE, Clearfil S3 Bond, and XenoV+ showed significantly higher microtensile bond strength results for the double-application technique compared with the single-application technique. Scotchbond Universal showed no difference between single- or double-application, irrespective of the storage conditions.
Conclusion
The results of this study show that improvements in bond strength of one-step self-etch adhesives by using the double-application technique are adhesive dependent.
Collapse
Affiliation(s)
- M Taschner
- Michael Taschner, DMD, assistant professor, University Hospital of Erlangen, Dental Clinic 1, Erlangen, Germany
| | - M Kümmerling
- Maria Kümmerling, post graduate student, University Hospital of Erlangen, Dental Clinic 1, Erlangen, Germany
| | - U Lohbauer
- Ulrich Lohbauer, MSc, PhD, FADM, Dental Clinic 1, Dental Materials Lab, Erlangen, Germany
| | - L Breschi
- Lorenzo Breschi, DDS, PhD, professor, Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Bologna, Italy
| | - A Petschelt
- Anselm Petschelt, DMD, PhD, professor and chair, University Hospital of Erlangen, Dental Clinic 1, Erlangen, Germany
| | - R Frankenberger
- Roland Frankenberger, DMD, PhD, professor and chair, Department of Operative Dentistry and Endodontology, University of Marburg, Marburg, Germany
| |
Collapse
|
49
|
Toledano M, Aguilera FS, Sauro S, Cabello I, Osorio E, Osorio R. Load cycling enhances bioactivity at the resin–dentin interface. Dent Mater 2014; 30:e169-88. [DOI: 10.1016/j.dental.2014.02.009] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2013] [Revised: 10/22/2013] [Accepted: 02/12/2014] [Indexed: 11/24/2022]
|
50
|
Zorba YO, Ilday NO, Bayındır YZ, Demirbuga S. Comparing the shear bond strength of direct and indirect composite inlays in relation to different surface conditioning and curing techniques. Eur J Dent 2014; 7:436-441. [PMID: 24932118 PMCID: PMC4053668 DOI: 10.4103/1305-7456.120679] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Objective: The aim of this study was to test the null hypothesis that different surface conditioning (etch and rinse and self-etch) and curing techniques (light cure/dual cure) had no effect on the shear bond strength of direct and indirect composite inlays. Materials and Methods: A total of 112 extracted human molar teeth were horizontally sectioned and randomly divided into two groups according to restoration technique (direct and indirect restorations). Each group was further subdivided into seven subgroups (n = 8) according to bonding agent (etch and rinse adhesives Scotchbond multi-purpose plus, All-Bond 3, Adper Single Bond and Prime Bond NT; and self-etch adhesives Clearfil Liner Bond, Futurabond DC and G bond). Indirect composites were cemented to dentin surfaces using dual-curing luting cement. Shear bond strength of specimens was tested using a Universal Testing Machine. Two samples from each subgroup were evaluated under Scanning electron microscopy to see the failing modes. Data was analyzed using independent sample t-tests and Tukey's tests. Results: Surface conditioning and curing of bonding agents were all found to have significant effects on shear bond strength (P < 0.05) of both direct and indirect composite inlays. With direct restoration, etch and rinse systems and dual-cured bonding agents yielded higher bond strengths than indirect restoration, self-etch systems and light-cured bonding agents. Conclusions: The results of the present study indicated that direct restoration to be a more reliable method than indirect restoration. Although etch and rinse bonding systems showed higher shear bond strength to dentin than self-etch systems, both systems can be safely used for the adhesion of direct as well as indirect restorations.
Collapse
Affiliation(s)
- Yahya Orcun Zorba
- Department of Restorative Dentistry, Faculty of Dentistry, Erciyes University, Kayseri, Turkiye
| | - Nurcan Ozakar Ilday
- Department of Restorative Dentistry, Faculty of Dentistry, Atatürk University, Erzurum, Turkiye
| | - Yusuf Ziya Bayındır
- Department of Restorative Dentistry, Faculty of Dentistry, Atatürk University, Erzurum, Turkiye
| | - Sezer Demirbuga
- Department of Restorative Dentistry, Faculty of Dentistry, Erciyes University, Kayseri, Turkiye
| |
Collapse
|