1
|
Preparation and characterization of novel as-cast Ti-Mo-Nb alloys for biomedical applications. Sci Rep 2022; 12:11874. [PMID: 35831317 PMCID: PMC9279454 DOI: 10.1038/s41598-022-14820-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 06/13/2022] [Indexed: 11/08/2022] Open
Abstract
Ti and its alloys are the most used metallic biomaterials devices due to their excellent combination of chemical and mechanical properties, biocompatibility, and non-toxicity to the human body. However, the current alloys available still have several issues, such as cytotoxicity of Al and V and high elastic modulus values, compared to human bone. β-type alloys, compared to α-type and (α + β)-type Ti alloys, have lower elastic modulus and higher mechanical strength. Then, new biomedical β-type alloys are being developed with non-cytotoxic alloying elements, such as Mo and Nb. Therefore, Ti-5Mo-xNb system alloys were prepared by argon arc melting. Chemical composition was evaluated by EDS analysis, and the density measurements were performed by Archimedes' method. The structure and microstructure of the alloys were obtained by X-ray diffraction and optical and scanning electron microscopy. Microhardness values were analyzed, and MTT and crystal violet tests were performed to assess their cytotoxicity. As the Nb concentration increases, the presence of the β-Ti phase also grows, with the Ti-5Mo-30Nb alloy presenting a single β-Ti phase. In contrast, the microhardness of the alloys decreases with the addition of Nb, except the Ti-5Mo-10Nb alloy, which has its microhardness increased probably due to the ω phase precipitation. Biological in-vitro tests showed that the alloys are not cytotoxic.
Collapse
|
2
|
Effect of Thermomechanical Treatments on Microstructure, Phase Composition, Vickers Microhardness, and Young’s Modulus of Ti-xNb-5Mo Alloys for Biomedical Applications. METALS 2022. [DOI: 10.3390/met12050788] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The development of new β-Ti alloys has been extensively studied in the medical field in recent times due to their more suitable mechanical properties, such as a relatively low Young’s modulus. This paper analyzes the influence of heat treatments (homogenization and annealing) and hot rolling on the microstructure, phase composition, and some mechanical properties of ternary alloys of the Ti-xNb-5Mo system, with an amount of Nb varying between 0 and 30 wt%. The samples are produced by argon arc melting. After melting, the samples are homogenized at 1000 °C for 24 h and are hot rolled and annealed at 1000 °C for 6 h with slow cooling. Structural and microstructural analyses are made using X-ray diffraction and optical and scanning electron microscopy. Mechanical properties are evaluated by Vickers microhardness and Young’s modulus. The amount of β phase increases after heat treatment and reduces after hot rolling. The microhardness and Young’s modulus of all heat-treated samples decrease when compared with the hot rolled ones. Some samples exhibit atypical Young’s modulus and microhardness values, such as 515 HV for the as-cast Ti-10Nb-5Mo sample, indicating the possible presence of ω phase in the microstructure. The Ti-30Nb-5Mo sample suffers less variation in its phase composition with thermomechanical treatments due to the β-stabilizing effect of the alloying elements. The studied mechanical properties indicate that the annealed Ti-30Nb-5Mo sample has potential for biomedical applications, exhibiting a Young’s modulus value of 69 GPa and a microhardness of 236 HV.
Collapse
|
3
|
Kong W, Cox SC, Lu Y, Villapun V, Xiao X, Ma W, Liu M, Attallah MM. The influence of zirconium content on the microstructure, mechanical properties, and biocompatibility of in-situ alloying Ti-Nb-Ta based β alloys processed by selective laser melting. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 131:112486. [PMID: 34857272 DOI: 10.1016/j.msec.2021.112486] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 09/24/2021] [Accepted: 10/09/2021] [Indexed: 01/16/2023]
Abstract
This study investigates Ti-Nb-Ta based β alloys with different zirconium additions (0, 5, 9 wt%) manufactured by SLM. A low level of as-fabricated defects is obtained: the relative density of TNT (Z) alloys is >99.97% with the keyhole size in a range of 3-20 μm. BF TEM images combining SAD patterns of TNT(Z) alloys show single β phase obtained inside the beta matrix; BF-STEM images reveal potential nano-scale grain boundary alpha phase precipitation. Zirconium functions as a neutral element in these high β-stabilized Ti-Nb-Ta based alloys. An increase in Vickers hardness and UTS caused by zirconium additions is observed, which is explained by beta grain refinement because higher degree of undercooling occurs. Corrosion ions of TNT(Z) alloys released from immersion testing at each time intervals show extremely small concentrations (<10 μg/L). It indicated that good biocompatibility during culture with the negligible corrosion ions. High strength-to-modulus ratio β Ti alloys together with excellent biological response show their prospect for biomedical applications.
Collapse
Affiliation(s)
- Weihuan Kong
- School of Materials and Metallurgy, University of Birmingham, Edgbaston B15 2TT, UK
| | - Sophie C Cox
- School of Chemical Engineering, University of Birmingham, Edgbaston B15 2TT, UK
| | - Yu Lu
- School of Materials and Metallurgy, University of Birmingham, Edgbaston B15 2TT, UK
| | - Victor Villapun
- School of Chemical Engineering, University of Birmingham, Edgbaston B15 2TT, UK
| | - Xiaoling Xiao
- Guangdong Institute of Analysis, Guangzhou 510651, PR China
| | - Wenyou Ma
- National Engineering Laboratory for Modern Materials Surface Engineering Technology, The Key Lab of Guangdong for Modern Surface Engineering Technology, Guangdong Institute of New Materials, Guangzhou 510651, PR China
| | - Min Liu
- National Engineering Laboratory for Modern Materials Surface Engineering Technology, The Key Lab of Guangdong for Modern Surface Engineering Technology, Guangdong Institute of New Materials, Guangzhou 510651, PR China.
| | - Moataz M Attallah
- School of Materials and Metallurgy, University of Birmingham, Edgbaston B15 2TT, UK.
| |
Collapse
|
4
|
Ion R, Cabon G, Gordin DM, Ionica E, Gloriant T, Cimpean A. Endothelial Cell Responses to a Highly Deformable Titanium Alloy Designed for Vascular Stent Applications. J Funct Biomater 2021; 12:33. [PMID: 34068852 PMCID: PMC8162573 DOI: 10.3390/jfb12020033] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 05/10/2021] [Accepted: 05/11/2021] [Indexed: 11/25/2022] Open
Abstract
Titanium alloys are widely used for biomedical applications due to their good biocompatibility. Nevertheless, they cannot be used for balloon expandable stents due to a lack of ductility compared to cobalt-chromium (Co-Cr) alloys and stainless steels. In this study, a new highly deformable Ti-16Nb-8Mo alloy was designed for such an application. However, the biological performance of a stent material is strongly influenced by the effect exerted on the behavior of endothelial cells. Therefore, the cellular responses of human umbilical vein endothelial cells (HUVECs), including morphological characteristics, cell viability and proliferation, and functional markers expression, were investigated to evaluate the biocompatibility of the alloy in the present study. The in vitro results demonstrated the suitability of this alloy for use as endovascular stents.
Collapse
Affiliation(s)
- Raluca Ion
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania; (R.I.); (E.I.)
| | - Gaëtan Cabon
- University of Rennes, INSA Rennes, CNRS, Institut des Sciences Chimiques de Rennes—UMR 6226, F-35000 Rennes, France; (G.C.); (D.-M.G.); (T.G.)
| | - Doina-Margareta Gordin
- University of Rennes, INSA Rennes, CNRS, Institut des Sciences Chimiques de Rennes—UMR 6226, F-35000 Rennes, France; (G.C.); (D.-M.G.); (T.G.)
| | - Elena Ionica
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania; (R.I.); (E.I.)
| | - Thierry Gloriant
- University of Rennes, INSA Rennes, CNRS, Institut des Sciences Chimiques de Rennes—UMR 6226, F-35000 Rennes, France; (G.C.); (D.-M.G.); (T.G.)
| | - Anisoara Cimpean
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania; (R.I.); (E.I.)
| |
Collapse
|
5
|
KARIM WO, JUMA JA, OMER KM, SALIH YM, HAMA AZIZ KH, AZIZ SB. Electropolishing and Mirror-like Preparation of Titanium in Choline Chloride-Ethylene Glycol Mixture Liquid. ELECTROCHEMISTRY 2020. [DOI: 10.5796/electrochemistry.20-00038] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Wrya O. KARIM
- Chemistry Department, College of Science, University of Sulaimani
| | - Jamil A. JUMA
- Department of Chemistry, Faculty of Science and Health, Koya University
| | - Khalid M. OMER
- Chemistry Department, College of Science, University of Sulaimani
- Department of Civil Engineering, College of Engineering, Komar University of Science and Technology
| | - Yousif M. SALIH
- Chemistry Department, College of Science, University of Sulaimani
| | | | - Shujahadeen B. AZIZ
- Advanced Polymeric Materials Research Lab., Department of Physics, College of Science, University of Sulaimani
| |
Collapse
|
6
|
Fabrication of high strength, antibacterial and biocompatible Ti-5Mo-5Ag alloy for medical and surgical implant applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 106:110165. [DOI: 10.1016/j.msec.2019.110165] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 01/22/2019] [Accepted: 09/05/2019] [Indexed: 01/11/2023]
|
7
|
Synthesis, characterization, in vitro biocompatibility and antibacterial properties study of nanocomposite materials based on hydroxyapatite-biphasic ZnO micro- and nanoparticles embedded in Alginate matrix. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 104:109965. [PMID: 31499965 DOI: 10.1016/j.msec.2019.109965] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Revised: 07/08/2019] [Accepted: 07/08/2019] [Indexed: 01/28/2023]
Abstract
The paper presents the results of studies of biocompatibility and antibacterial properties of multiphase nanocomposite materials based on HA-Alg-ZnO (hydroxyapatite‑sodium alginate-biphasic zinc oxide) and HA-ZnO (hydroxyapatite‑zinc oxide), which were synthesized from the analytically pure calcium nitrate tetrahydrate, ammonium hydrophosphate, hydrous ammonia, zinc nitrate hexahydrate and calcium chloride. The samples' antimicrobial activity assessment was carried out on Gram-negative (E. coli, P. aeruginosa) and Gram-positive bacteria (S. aureus and S. epidermidis) test cultures by the co-incubation and modified "agar diffusion" methods. The murine fibroblast cells were used for the biocompatibility tests and cytotoxicity evaluation. It was shown that synthesized nanocomposite material has a multiphase nanoscale architecture, where ZnO nanocrystals are represented by two lattices: cubic and hexagonal. The possible explanation of ZnO nanocrystals' phase transition is given. At the same time, a partial replacement of Ca2+ ions by Zn2+ ions in the HA lattice possibly occurs due to processing of composite by US radiation. The replacement was evidenced by the non-stoichiometric Ca/P ratio < 2.16, OPO lines' shifting on FTIR spectrum and TEM analysis. The studied composite demonstrate a pronounced antibacterial activity due to the incorporation of ZnO particles into sodium alginate and moistened powder of hydroxyapatite. Both forms of HA-ZnO (suspension) and HA-Alg-ZnO (beads) are biocompatible. An interpretation of the process of Zn ions' embedding into hydroxyapatite and alginate matrix is given, as well as their influence on the biomimetic composite properties is discussed in details. STATEMENT OF SIGNIFICANCE: A number of studies have shown that Zn effectively inhibits the growth and development of bacteria and yeast fungi. Zinc plays an important role in the creation of new antimicrobial agents, and zinc-doped hydroxyapatite will find further application in biomedicine. In this regard, the phase states of zinc oxide, as well as the processes of calcium replacement by zinc in calcium apatite and in alginate should be explored fully. Nowadays we have lack of information and the study's results about those interactions. The present study provides data of the multiphase morphology, antimicrobial activity, biocompatibility and cytotoxicity of the biomimetic nanostructured composite materials, such as sodium alginate/hydroxyapatite/ZnO based granules and hydroxyapatite/ZnO based hydrogel, and the establishing Zn ions' behavior patterns with another composite components.
Collapse
|
8
|
Bai W, Xu G, Tan M, Yang Z, Zeng L, Wu D, Liu L, Zhang L. Diffusivities and Atomic Mobilities in bcc Ti-Mo-Zr Alloys. MATERIALS (BASEL, SWITZERLAND) 2018; 11:E1909. [PMID: 30297670 PMCID: PMC6212804 DOI: 10.3390/ma11101909] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 10/03/2018] [Accepted: 10/05/2018] [Indexed: 11/16/2022]
Abstract
β-type (with bcc structure) titanium alloys have been widely used as artificial implants in the medical field due to their favorable properties. Among them, Ti-Mo alloy attracted numerous interests as metallic biomaterials. Understanding of kinetic characteristics of Ti alloys is critical to understand and manipulate the phase transformation and microstructure evolution during homogenization and precipitation. In this work, diffusion couple technique was employed to investigate the diffusion behaviors in bcc Ti-Mo-Zr alloys. The diffusion couples were prepared and annealed at 1373 K for 72 h and 1473 K for 48 h, respectively. The composition-distance profiles were obtained via electron probe micro-analysis (EPMA). The chemical diffusion coefficients and impurity diffusion coefficients were extracted via the Whittle-Green method and Hall method. The obtained diffusion coefficients were assessed to develop a self-consistent atomic mobility database of bcc phase in Ti-Mo-Zr system. The calculated diffusion coefficients were compared with the experimental results. They showed good agreement. Simulations were implemented by Dictra Module in Thermo-Calc software. The predicted composition-distance profiles, inter-diffusion flux, and diffusion paths are consistent with experimental data, confirming the accuracy of the database.
Collapse
Affiliation(s)
- Weimin Bai
- School of Material Science and Engineering, Central South University, Changsha 410083, China.
| | - Guanglong Xu
- Tech Institute for Advanced Materials & School of Materials Science and Engineering, Nanjing Tech University, Nanjing 211800, China.
| | - Mingyue Tan
- School of Material Science and Engineering, Central South University, Changsha 410083, China.
| | - Zhijie Yang
- School of Material Science and Engineering, Central South University, Changsha 410083, China.
| | - Lijun Zeng
- School of Material Science and Engineering, Central South University, Changsha 410083, China.
| | - Di Wu
- School of Material Science and Engineering, Central South University, Changsha 410083, China.
| | - Libin Liu
- School of Material Science and Engineering, Central South University, Changsha 410083, China.
| | - Ligang Zhang
- School of Material Science and Engineering, Central South University, Changsha 410083, China.
| |
Collapse
|
9
|
|
10
|
Buente D, Bryant M, Ward M, Neville A, Morlock M, Huber G. The taper corrosion pattern observed for one bi-modular stem design is related to geometry-determined taper mechanics. Med Eng Phys 2017. [PMID: 28647286 DOI: 10.1016/j.medengphy.2017.06.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Bi-modular primary hip stems exhibit high revision rates owing to corrosion at the stem-neck taper, and are associated with local adverse tissue reactions. The aim of this study was to relate the wear patterns observed for one bi-modular design to its design-specific stem-neck taper geometry. Wear patterns and initial geometry of the taper junctions were determined for 27 retrieved bi-modular primary hip arthroplasty stems (Rejuvenate, Stryker Orthopaedics) using a tactile coordinate-measuring device. Regions of high-gradient wear patterns were additionally analyzed via optical and electron microscopy. The determined geometry of the taper junction revealed design-related engagement at its opening (angle mismatch), concentrated at the medial and lateral apexes (axes mismatch). A patch of retained topography on the proximal medial neck-piece taper apex was observed, surrounded by regions of high wear. On the patch, a deposit from the opposing female stem taper-containing Ti, Mo, Zr, and O-was observed. High stress concentrations were focused at the taper apexes owing to the specific geometry. A medial canting of the components may have augmented the inhomogeneous stress distributions in vivo. In the regions with high normal loads interfacial slip and consequently fretting was inhibited, which explains the observed pattern of wear.
Collapse
Affiliation(s)
- Dennis Buente
- TUHH Hamburg University of Technology, Institute of Biomechanics, Denickestrasse 15, 21073 Hamburg, Germany.
| | - Michael Bryant
- University of Leeds, Faculty of Engineering Institute of Materials and Research/Functional Surfaces, Leeds LS2 9JT, UK.
| | - Michael Ward
- University of Leeds, Faculty of Engineering Institute of Materials and Research/Functional Surfaces, Leeds LS2 9JT, UK.
| | - Anne Neville
- University of Leeds, Faculty of Engineering Institute of Materials and Research/Functional Surfaces, Leeds LS2 9JT, UK.
| | - Michael Morlock
- TUHH Hamburg University of Technology, Institute of Biomechanics, Denickestrasse 15, 21073 Hamburg, Germany.
| | - Gerd Huber
- TUHH Hamburg University of Technology, Institute of Biomechanics, Denickestrasse 15, 21073 Hamburg, Germany.
| |
Collapse
|
11
|
A Comparison of Blood Metal Ions in Total Hip Arthroplasty Using Metal and Ceramic Heads. J Arthroplasty 2016; 31:2215-20. [PMID: 27108055 DOI: 10.1016/j.arth.2016.03.024] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2015] [Revised: 02/29/2016] [Accepted: 03/11/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND In recent time, metal ion debris and adverse local tissue reaction have reemerged as an area of clinical concern with the use of large femoral heads after total hip arthroplasty (THA). METHODS Between June 2014 and January 2015, 60 patients with a noncemented THA using a titanium (titanium, molybdenum, zirconium, and iron alloy) femoral stem and a V40 trunnion were identified with a minimum 5-year follow-up. All THAs had a 32- or 36-mm metal (n = 30) or ceramic (n = 30) femoral head coupled with highly cross-linked polyethylene. Cobalt, chromium, and nickel ions were measured. RESULTS Patients with metal heads had detectable cobalt and chromium levels. Cobalt levels were detectable in 17 (56.7%) patients with a mean of 2.0 μg/L (range: <1.0-10.8 μg/L). Chromium levels were detectable in 5 (16.7%) patients with a mean of 0.3 μg/L (range: <1.0-2.2 μg/L). All patients with a ceramic head had nondetectable cobalt and chromium levels. Cobalt and chromium levels were significantly higher with metal heads compared to ceramic heads (P < .01). Cobalt levels were significantly higher with 36-mm metal heads compared with 32-mm heads (P < .01). Seven patients with metal femoral heads had mild hip symptoms, 4 of whom had positive findings of early adverse local tissue reaction on magnetic resonance imaging. All ceramic THA was asymptomatic. CONCLUSION The incidence and magnitude of cobalt and chromium levels is higher in metal heads compared to ceramic heads with this implant system (P < .01). Thirty-six millimeter metal femoral heads result in larger levels of cobalt compared with 32-mm metal heads.
Collapse
|
12
|
Mechanical and electrochemical characterisation of new Ti–Mo–Nb–Zr alloys for biomedical applications. J Mech Behav Biomed Mater 2016; 60:68-77. [DOI: 10.1016/j.jmbbm.2015.12.023] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Revised: 12/15/2015] [Accepted: 12/18/2015] [Indexed: 11/22/2022]
|
13
|
Miyatake K, Jinno T, Koga D, Yamauchi Y, Muneta T, Okawa A. Comparison of Different Materials and Proximal Coatings Used for Femoral Components in One-Stage Bilateral Total Hip Arthroplasty. J Arthroplasty 2015; 30:2237-41. [PMID: 26190568 DOI: 10.1016/j.arth.2015.06.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2015] [Revised: 05/15/2015] [Accepted: 06/10/2015] [Indexed: 02/01/2023] Open
Abstract
To evaluate the mid-term effects of different materials and coatings used for femoral components, we prospectively performed 21 one-stage bilateral total hip arthroplasties using 2 anatomical stems which have identical geometries, randomized to side. One stem was made of Ti6Al4V alloy and had a hydroxyapatite coating on grit-blasted surface proximally, and the other was made of TMZF™ alloy and had a proximal coating of hydroxyapatite in addition to an arc-deposited titanium surface coating. Although we found extensions of radiopaque lines to the surface of coatings of seven grit-blasted stems whereas we found none in the case of the arc-deposited titanium stems, all hips showed excellent clinical and radiological outcomes as shown by radiographs and bone mineral density at the final follow-up, average 5.5 years postoperatively.
Collapse
Affiliation(s)
- Kazumasa Miyatake
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tetsuya Jinno
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| | - Daisuke Koga
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yuki Yamauchi
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| | - Takeshi Muneta
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| | - Atsushi Okawa
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
14
|
Kiran M, Boscainos PJ. Adverse reactions to metal debris in metal-on-polyethylene total hip arthroplasty using a titanium-molybdenum-zirconium-iron alloy stem. J Arthroplasty 2015; 30:277-81. [PMID: 25466166 DOI: 10.1016/j.arth.2014.06.030] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Revised: 04/28/2014] [Accepted: 06/24/2014] [Indexed: 02/01/2023] Open
Abstract
We report a series of three patients who underwent uncemented total hip arthroplasty with a modular titanium-molybdenum-zirconium-iron stem and a cobalt-chrome-molybdenum head on an ultra-high molecular weight highly cross-linked polyethylene liner bearing. All three cases subsequently developed pain and adverse reaction to metal debris, leading to revision of the implants within thirty-six months. They were subsequently found to have hypersensitivity to cobalt or chromium. However where tested, blood metal ion levels were within MHRA guideline limits. Corrosion was noted at the taper-trunnion junction. It is possible, that the multi alloy head-neck combination may lead to corrosion. Hypersensitivity to metal ions may result to ARMD at lower metal ion levels. The use of ceramic heads may help avoid this risk.
Collapse
Affiliation(s)
- Manish Kiran
- Department of Trauma and Orthopaedic Surgery, NHS Tayside, Scotland, UK; Department of Trauma and Orthopaedic Surgery, School of Medicine, University of Dundee, Scotland, UK
| | - Petros J Boscainos
- Department of Trauma and Orthopaedic Surgery, NHS Tayside, Scotland, UK; Department of Trauma and Orthopaedic Surgery, School of Medicine, University of Dundee, Scotland, UK
| |
Collapse
|
15
|
Abstract
Stainless steel, titanium alloys and cobalt chromium molybdenum alloys are classified under the metallic biomaterials whereby various surgical implants, prosthesis and medical devices are manufactured to replace missing body parts which may be lost through accident, trauma, disease, or congenital conditions. Among these materials, cobalt chromium molybdenum alloys are the common cobalt base alloy used for orthopedic implants due their excellence properties which include high corrosion resistance, high strength, high hardness, high creep resistance, biocompatibility and greater wear resistance. This paper summarises the various aspects and characteristic of metallic biomaterials such as stainless steel, titanium and cobalt chromium alloys for medical applications especially for orthopedic implant. These include material properties, biocompatibility, advantages and limitations for medical implants applications.
Collapse
|
16
|
Neacsu P, Gordin DM, Mitran V, Gloriant T, Costache M, Cimpean A. In vitro performance assessment of new beta Ti-Mo-Nb alloy compositions. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 47:105-13. [PMID: 25492178 DOI: 10.1016/j.msec.2014.11.023] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Revised: 10/08/2014] [Accepted: 11/06/2014] [Indexed: 10/24/2022]
Abstract
New β-titanium based alloys with low Young's modulus are currently required for the next generation of metallic implant materials to ensure good mechanical compatibility with bone. Several of these are representatives of the ternary Ti-Mo-Nb system. The aim of this paper is to assess the in vitro biological performance of five new low modulus alloy compositions, namely Ti12Mo, Ti4Mo32Nb, Ti6Mo24Nb, Ti8Mo16Nb and Ti10Mo8Nb. Commercially pure titanium (cpTi) was used as a reference material. Comparative studies of cell activity exhibited by MC3T3-E1 pre-osteoblasts over short- and long-term culture periods demonstrated that these newly-developed metallic substrates exhibited an increased biocompatibility in terms of osteoblast proliferation, collagen production and extracellular matrix mineralization. Furthermore, all analyzed biomaterials elicited an almost identical cell response. Considering that macrophages play a pivotal role in bone remodeling, the behavior of a monocyte-macrophage cell line, RAW 264.7, was also investigated showing a slightly lower inflammatory response to Ti-Mo-Nb biomaterials as compared with cpTi. Thus, the biological performances together with the superior mechanical properties recommend these alloys for bone implant applications.
Collapse
Affiliation(s)
- Patricia Neacsu
- University of Bucharest, Department of Biochemistry and Molecular Biology, 91-95 Spl. Independentei, 050095 Bucharest, Romania
| | - Doina-Margareta Gordin
- INSA Rennes, UMR CNRS 6226 ISCR/Chimie-Métallurgie, 20 avenue des Buttes de Coësmes, F-35043 Rennes, Cedex, France
| | - Valentina Mitran
- University of Bucharest, Department of Biochemistry and Molecular Biology, 91-95 Spl. Independentei, 050095 Bucharest, Romania
| | - Thierry Gloriant
- INSA Rennes, UMR CNRS 6226 ISCR/Chimie-Métallurgie, 20 avenue des Buttes de Coësmes, F-35043 Rennes, Cedex, France
| | - Marieta Costache
- University of Bucharest, Department of Biochemistry and Molecular Biology, 91-95 Spl. Independentei, 050095 Bucharest, Romania
| | - Anisoara Cimpean
- University of Bucharest, Department of Biochemistry and Molecular Biology, 91-95 Spl. Independentei, 050095 Bucharest, Romania.
| |
Collapse
|
17
|
|
18
|
Firouzi D, Youssef A, Amer M, Srouji R, Amleh A, Foucher DA, Bougherara H. A new technique to improve the mechanical and biological performance of ultra high molecular weight polyethylene using a nylon coating. J Mech Behav Biomed Mater 2014; 32:198-209. [DOI: 10.1016/j.jmbbm.2014.01.001] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2013] [Revised: 12/30/2013] [Accepted: 01/06/2014] [Indexed: 01/26/2023]
|
19
|
MITRA TAPAS, SAILAKSHMI G, GNANAMANI A. Could glutaric acid (GA) replace glutaraldehyde in the preparation of biocompatible biopolymers with high mechanical and thermal properties? J CHEM SCI 2014. [DOI: 10.1007/s12039-013-0543-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
20
|
Corrosion Behavior of a New Ti–3Mo Alloy in Simulated Body Fluid for Biomedical Applications. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING 2013. [DOI: 10.1007/s13369-013-0873-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
21
|
Lass R, Kolb A, Skrbensky G, Reinisch G, Kubista B, Giurea A, Windhager R, Kotz R. A cementless hip system with a new surface for osseous integration. INTERNATIONAL ORTHOPAEDICS 2013; 38:703-9. [PMID: 24114250 DOI: 10.1007/s00264-013-2135-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2013] [Accepted: 09/17/2013] [Indexed: 11/25/2022]
Abstract
PURPOSE The failure of total hip systems caused by wear-particle-induced loosening has focused interest on factors potentially affecting wear rate. Remnants of the blasting material were reported on grit-blasted surfaces for cementless fixation. These particles are believed to cause third-body wear and implant loosening. The purpose of this study was to evaluate the early clinical and radiological outcomes of a cementless hip system with a new, contamination-free, roughened surface with regard to prosthesis-related failures. METHODS Between May 2004 and March 2009, 202 consecutive primary total hip arthroplasties (THAs) (192 patients with a mean age of 62.6 years) were performed using a cementless stem (Hipstar®) and a hemispherical acetabular cup (Trident®). RESULTS At a minimum follow-up of two years, five revisions (2.5%) due to aseptic loosening of the stem and three (1.5%) of the cup were necessary. The cumulative rate of prostheses survival, counting revision of both components and with aseptic failure as end point, was 92.9% at 8.8 years. Radiolucent lines up to three millimetres were evaluated in the proximal part of the femur in 61% of cases. CONCLUSIONS Although the incidence of radiolucent lines was decreased, the revision rate was considerably increased compared to other uncemented hip implants with grit-blasted surfaces in the short- to mid-term follow-up of our study. Subsequent studies are needed to confirm whether these changes in implant material and surface affect the radiological and clinical outcome in the long term.
Collapse
Affiliation(s)
- Richard Lass
- Department of Orthopaedics and Orthopaedic Surgery, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria,
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Mitra T, Sailakshmi G, Gnanamani A, Mandal AB. The Effect of Pimelic Acid Interaction on the Mechanical and Thermal Properties of Chitosan and Collagen. INT J POLYM MATER PO 2013. [DOI: 10.1080/00914037.2013.769161] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
23
|
Li J, Shi LL, Zhu ZD, He Q, Ai HJ, Xu J. Zr61Ti2Cu25Al12 metallic glass for potential use in dental implants: Biocompatibility assessment by in vitro cellular responses. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 33:2113-21. [DOI: 10.1016/j.msec.2013.01.033] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2012] [Accepted: 01/15/2013] [Indexed: 12/01/2022]
|
24
|
Sailakshmi G, Mitra T, Sinha S, Chatterjee S, Gnanamani A, Mandal AB. Suberic Acid Acts as a Dissolving Agent as Well as a Crosslinker for Natural Polymers (Carbohydrate and Protein): A Detailed Discussion on the Chemistry Behind the Interaction. JOURNAL OF MACROMOLECULAR SCIENCE PART A-PURE AND APPLIED CHEMISTRY 2012. [DOI: 10.1080/10601325.2012.696994] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
25
|
Mitra T, Sailakshmi G, Gnanamani A, Mandal AB. Preparation and characterization of malonic acid cross-linked chitosan and collagen 3D scaffolds: an approach on non-covalent interactions. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2012; 23:1309-1321. [PMID: 22367159 DOI: 10.1007/s10856-012-4586-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2011] [Accepted: 02/11/2012] [Indexed: 05/31/2023]
Abstract
The present study emphasizes the influence of non-covalent interactions on the mechanical and thermal properties of the scaffolds of chitosan/collagen origin. Malonic acid (MA), a bifuncitonal diacid was chosen to offer non-covalent cross-linking. Three dimensional scaffolds was prepared using chitosan at 1.0% (w/v) and MA at 0.2% (w/v), similarly collagen 0.5% (w/v) and MA 0.2% (w/v) and characterized. Results on FT-IR, TGA, DSC, SEM and mechanical properties (tensile strength, stiffness, Young's modulus, etc.) assessment demonstrated the existence of non-covalent interaction between MA and chitosan/collagen, which offered flexibility and high strength to the scaffolds suitable for tissue engineering research. Studies using NIH 3T3 fibroblast cells suggested biocompatibility nature of the scaffolds. Docking simulation study further supports the intermolecular hydrogen bonding interactions between MA and chitosan/collagen.
Collapse
Affiliation(s)
- Tapas Mitra
- Microbiology Division, Central Leather Research Institute (CSIR, New Delhi), Adyar, Chennai 600020, Tamil Nadu, India
| | | | | | | |
Collapse
|
26
|
Zhao X, Niinomi M, Nakai M, Hieda J. Beta type Ti-Mo alloys with changeable Young's modulus for spinal fixation applications. Acta Biomater 2012; 8:1990-7. [PMID: 22326686 DOI: 10.1016/j.actbio.2012.02.004] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2011] [Revised: 01/18/2012] [Accepted: 02/02/2012] [Indexed: 11/26/2022]
Abstract
To develop a novel biomedical titanium alloy with a changeable Young's modulus via deformation-induced ω phase transformation for the spinal rods in spinal fixation devices, a series of metastable β type binary Ti-(15-18)Mo alloys were prepared. In this study, the microstructures, Young's moduli and tensile properties of the alloys were systemically examined to investigate the effects of deformation-induced ω phase transformation on their mechanical properties. The springback of the optimal alloy was also examined. Ti-(15-18)Mo alloys subjected to solution treatment comprise a β phase and a small amount of athermal ω phase, and they have low Young's moduli. All the alloys investigated in this study show an increase in the Young's modulus owing to deformation-induced ω phase transformation during cold rolling. The deformation-induced ω phase transformation is accompanied with {332}(β) mechanical twinning. This resulted in the maintenance of acceptable ductility with relatively high strength. Among the examined alloys, the Ti-17Mo alloy shows the lowest Young's modulus and the largest increase in the Young's modulus. This alloy exhibits small springback and could be easily bent to the required shape during operation. Thus, Ti-17Mo alloy is considered to be a potential candidate for the spinal rods in spinal fixation devices.
Collapse
|
27
|
Mitra T, Sailakshmi G, Gnanamani A, Mandal AB. Adipic acid interaction enhances the mechanical and thermal stability of natural polymers. J Appl Polym Sci 2012. [DOI: 10.1002/app.36957] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
28
|
Effects of molybdenum content on the structure and mechanical properties of as-cast Ti–10Zr-based alloys for biomedical applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2012. [DOI: 10.1016/j.msec.2011.12.003] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
29
|
Lindgren JU, Brismar BH, Wikstrom AC. Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis. ACTA ACUST UNITED AC 2011; 93:1427-30. [DOI: 10.1302/0301-620x.93b10.27645] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A 70-year-old man with an uncemented metal-on-polyethylene total hip prosthesis underwent revision arthroplasty 33 months later because of pain, swelling and recurrent dislocation. There appeared to be corrosion and metal release from the prosthetic head, resulting in pseudotumour formation and severe local soft-tissue destruction. The corrosion occurred at the junction between the titanium-molybdenum-zirconium-iron taper and the cobalt-chrome-molybdenum head, but the mechanism was unproven.
Collapse
Affiliation(s)
- J. U. Lindgren
- Karolinska University Hospital, Department
of Orthopaedics K54, Huddinge, S14186
Stockholm, Sweden
| | - B. H. Brismar
- Karolinska University Hospital, Department
of Orthopaedics K54, Huddinge, S14186
Stockholm, Sweden
| | - A. C. Wikstrom
- Karolinska University Hospital, Clinical
Immunology and Transfusion Medicine F79, Huddinge, SE-14186
Stockholm, Sweden
| |
Collapse
|
30
|
O'Flynn KP, Stanton KT. Optimisation of the enamelling of an apatite-mullite glass-ceramic coating on Ti6Al4V. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2011; 22:2035-2044. [PMID: 21773840 DOI: 10.1007/s10856-011-4392-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2011] [Accepted: 07/09/2011] [Indexed: 05/31/2023]
Abstract
Apatite-mullite glass-ceramics (AMGCs) are under investigation as a potential alternative to hydroxyapatite (HA) as a coating for cementless fixation of orthopaedic implants. These materials have tailorable mechanical and chemical properties that make them attractive for use as bioactive coatings. Here, AMGC coatings on Ti(6)Al(4)V were investigated to determine an improved heat treatment regime using a systematic examination of the different inputs: composition of glass, nucleation hold and crystallisation hold. An upper limit to the heat treatment temperature was determined by the α + β --> β of Ti(6)Al(4)V at 970°C. The glass composition was modified to produce different crystallisation temperatures and sintering characteristics. A glass was found that is fully crystalline below 970°C and has good sinterability. The effects of different heat treatment time and temperature combinations on the coating and substrate morphologies were examined and the most suitable combination determined. This sample was further investigated and was found to have qualitatively good adhesion and evidence of an interfacial reaction region between the coating and substrate indicating that a chemical reaction had occurred. Oxygen infiltration into the substrate was quantified and the new route was shown to result in a 63% reduction in penetration depth.
Collapse
Affiliation(s)
- Kevin P O'Flynn
- School of Mechanical and Materials Engineering, University College Dublin, Belfield, Dublin 4, Ireland
| | | |
Collapse
|
31
|
Ho WF, Wu SC, Chang HH, Hsu HC. Structure and mechanical properties of Ti–5Cr based alloy with Mo addition. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2010. [DOI: 10.1016/j.msec.2010.04.006] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
32
|
Vasilescu E, Drob P, Raducanu D, Cojocaru VD, Cinca I, Iordachescu D, Ion R, Popa M, Vasilescu C. In vitro biocompatibility and corrosion resistance of a new implant titanium base alloy. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2010; 21:1959-1968. [PMID: 20336353 DOI: 10.1007/s10856-010-4057-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2009] [Accepted: 03/11/2010] [Indexed: 05/29/2023]
Abstract
One objective of this work was to study the corrosion resistance of the new implant Ti-10Zr-5Ta-5Nb alloy in physiological fluids of different pH values, simulating the extreme functional conditions. Another objective was in vitro biocompatibility evaluation of the new alloy using human fetal osteoblast cell line hFOB 1.19. Cytocompatibility was assessed by determination of possible material cytotoxic effects, cell morphology and cell adhesion. The thermo-mechanical processing of the new implant alloy consisted in plastic deformation (almost 90%) performed by hot rolling accompanied by an initial and final heat treatment. The new Ti-10Zr-5Ta-5Nb alloy presented self-passivation, with a large passive potential range and low passive current densities, namely, a very good anticorrosive resistance in Ringer solution of acid, neutral and alkaline pH values. Cell viability was not affected by the alloy substrate presence and a very good compatibility was noticed.
Collapse
Affiliation(s)
- E Vasilescu
- Institute of Physical Chemistry "Ilie Murgulescu", Spl. Independentei 202, Bucharest 060021, Romania.
| | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Ho WF, Lai CH, Hsu HC, Wu SC. Surface modification of a Ti-7.5Mo alloy using NaOH treatment and Bioglass coating. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2010; 21:1479-1488. [PMID: 20069344 DOI: 10.1007/s10856-010-3990-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2009] [Accepted: 01/04/2010] [Indexed: 05/28/2023]
Abstract
The objective of this study was to propose a surface modification for a low-modulus Ti-7.5Mo alloy to initiate the formation of hydroxyapatite (HA) during in vitro bioactivity tests in simulated body fluid (SBF). Specimens of commercially pure titanium (c.p. Ti) and Ti-7.5Mo were initially immersed in a 15 M NaOH solution at 60 degrees C for 24 h, resulting in the formation of a porous network structure composed of sodium titanate (Na(2)Ti(5)O(11)). Afterwards, bioactive Bioglass particles were deposited on the surface of NaOH-treated c.p. Ti and Ti-7.5Mo. The specimens were then immersed in SBF at 37 degrees C for 1, 7 and 28 days, respectively. The apatite-forming ability of the NaOH-treated and Bioglass-coated Ti-7.5Mo was higher than that of the c.p. Ti under the same condition. The X-ray diffraction (XRD) and energy-dispersive X-ray spectroscopy (EDS) results indicated that the deposited amounts of calcium phosphate were much greater for the surface-treated Ti-7.5Mo than for the c.p. Ti, a finding attributable to or correlated with the higher pH value of the SBF containing surface-treated Ti-7.5Mo. Moreover, in the surface-treated Ti-7.5Mo, the pH value of the SBF approached a peak of 7.66 on the first day. A combination of NaOH treatment and subsequent Bioglass coating was successfully used to initiate in vitro HA formation in the surface of the Ti-7.5Mo alloy.
Collapse
Affiliation(s)
- Wen-Fu Ho
- Department of Materials Science and Engineering, Da-Yeh University, 168 University Road, Dacun, Changhua, 51591, Taiwan, ROC.
| | | | | | | |
Collapse
|
34
|
Stanton KT, O'Flynn KP, Nakahara S, Vanhumbeeck JF, Delucca JM, Hooghan B. Study of the interfacial reactions between a bioactive apatite-mullite glass-ceramic coating and titanium substrates using high angle annular dark field transmission electron microscopy. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2009; 20:851-857. [PMID: 19034617 DOI: 10.1007/s10856-008-3650-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2008] [Accepted: 11/03/2008] [Indexed: 05/27/2023]
Abstract
Glass of generic composition SiO(2) . Al(2)O(3) . P(2)O(5) . CaO . CaF(2) will crystallise predominantly to apatite and mullite upon heat-treatment. Such ceramics are bioactive, osseoconductive, and have a high resistance to fracture. As a result, they are under investigation for use as biomedical device coatings, and in particular for orthopaedic implants. Previous work has shown that the material can be successfully enamelled to titanium with an interfacial reaction zone produced during heat treatment. The present study uses high angle annular dark field transmission electron microscopy (HAADF-TEM) to conduct a detailed examination of this region. Results show evidence of complex interfacial reactions following the diffusion of titanium into an intermediate layer and the production of titanium silicides and titanium phosphides. These results confirm previously hypothesised mechanisms for the bonding of silicate bioceramics with titanium alloys.
Collapse
Affiliation(s)
- Kenneth T Stanton
- School of Electrical, Electronic and Mechanical Engineering, University College Dublin, Belfield, Dublin 4, Ireland.
| | | | | | | | | | | |
Collapse
|
35
|
Cáceres D, Munuera C, Ocal C, Jiménez J, Gutiérrez A, López M. Nanomechanical properties of surface-modified titanium alloys for biomedical applications. Acta Biomater 2008; 4:1545-52. [PMID: 18499544 DOI: 10.1016/j.actbio.2008.04.009] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2007] [Revised: 04/09/2008] [Accepted: 04/16/2008] [Indexed: 10/22/2022]
Abstract
The mechanical properties of the oxide layers developed at elevated temperature on three vanadium-free titanium alloys of interest for biomedical applications were investigated by means of the nanoindentation technique. The as-received alloys (Ti-13Nb-13Zr, Ti-15Zr-4Nb and Ti-7Nb-6Al) and their oxide scales formed by reaction with air at 750 degrees C for several oxidation times were analysed comparatively. In particular, the hardness and the Young's modulus exhibit larger values for the thermally oxidized alloys than for the untreated specimens. However, the Ti-7Nb-6Al alloy shows a different tendency to that of the TiNbZr alloys, which seems to be related to a different oxide layer growth as a function of the oxidation time.
Collapse
|
36
|
Delvat E, Gordin DM, Gloriant T, Duval JL, Nagel MD. Microstructure, mechanical properties and cytocompatibility of stable beta Ti-Mo-Ta sintered alloys. J Mech Behav Biomed Mater 2008; 1:345-51. [PMID: 19627799 DOI: 10.1016/j.jmbbm.2008.01.006] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2007] [Revised: 01/28/2008] [Accepted: 01/29/2008] [Indexed: 11/16/2022]
Abstract
We have synthesized titanium-based alloys containing molybdenum and tantalum elements by powder metallurgy. The microstructure, the residual porosity and the mechanical properties of the sintered Ti-Mo and Ti-Ta-Mo alloys were investigated by using optical and electronic microscopy, X-ray diffraction, microhardness and compression tests. The cytocompatibility of the different alloys was evaluated by the assessment of bone cell density, migration and adhesion after 14 days incubation. All the alloys present a high ductility and an excellent cytocompatibility, which make these materials useful for medical implants.
Collapse
Affiliation(s)
- E Delvat
- INSA Rennes, UMR CNRS 6226 Sciences Chimiques de Rennes/Chimie-Métallurgie, 20 avenue des Buttes de Coësmes, F-35043 Rennes cedex, France
| | | | | | | | | |
Collapse
|
37
|
Eisenbarth E, Velten D, Müller M, Thull R, Breme J. Biocompatibility of β-stabilizing elements of titanium alloys. Biomaterials 2004; 25:5705-13. [PMID: 15147816 DOI: 10.1016/j.biomaterials.2004.01.021] [Citation(s) in RCA: 239] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2003] [Accepted: 01/17/2004] [Indexed: 11/19/2022]
Abstract
In comparison to the presently used alpha + beta titanium alloys for biomedical applications, beta-titanium alloys have many advantageous mechanical properties, such as an improved wear resistance, a high elasticity and an excellent cold and hot formability. This will promote their future increased application as materials for orthopaedic joint replacements. Not all elements with beta-stabilizing properties in titanium alloys are suitable for biomaterial applications-corrosion and wear processes cause a release of these alloying elements to the surrounding tissue. In this investigation, the biocompability of alloying elements for beta- and near beta-titanium alloys was tested in order to estimate their suitability for biomaterial components. Titanium (grade 2) and the implant steel X2CrNiMo18153 (AISI 316 L) were tested as reference materials. The investigation included the corrosion properties of the elements, proliferation, mitochondrial activity, cell morphology and the size of MC3T3-E1 cells and GM7373 cells after 7 days incubation in direct contact with polished slices of the metals. The statistical significance was considered by Weir-test and Lord-test (alpha = 0.05). The biocompatibility range of the investigated metals is (decreasing biocompatibility): niobium-tantalum, titanium, zirconium-aluminium-316 L-molybdenum.
Collapse
Affiliation(s)
- E Eisenbarth
- Universität des Saarlandes, Lehrstuhl für metallische Werkstoffe, D-66041 Saarbrücken, Germany.
| | | | | | | | | |
Collapse
|
38
|
Mei Y, Kumar A, Gao W, Gross R, Kennedy SB, Washburn NR, Amis EJ, Elliott JT. Biocompatibility of sorbitol-containing polyesters. Part I: Synthesis, surface analysis and cell response in vitro. Biomaterials 2004; 25:4195-201. [PMID: 15046909 DOI: 10.1016/j.biomaterials.2003.10.087] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2003] [Accepted: 10/10/2003] [Indexed: 11/15/2022]
Abstract
A series of sorbitol-containing polyesters were synthesized via a one-pot lipase-catalyzed condensation polymerization. Thin films were prepared by spin coating on silicon wafers and surfaces were analyzed by tapping mode atomic force microscopy and contact angle measurements. Surface morphologies and surface energies across the series of polyester films, including a poly(epsilon-caprolactone) (PCL) control were nearly indistinguishable. Biocompatibility of the sorbitol-containing polyester series was evaluated against a PCL control by measuring cell spreading and proliferation of a mouse fibroblast 3T3 cell line in vitro. Results confirmed that the sorbitol-containing polyester surfaces elicited cell behavior similar to the PCL control. These results establish the sorbitol-containing polyester series as a promising material for tissue engineering research and development.
Collapse
Affiliation(s)
- Ying Mei
- Department of Chemistry and Chemical Engineering, NSF-I/UCRC Center for Biocatalysis and Bioprocessing of Macromolecules, Polytechnic University, Six Metrotech Center, Brooklyn, NY 11201, USA
| | | | | | | | | | | | | | | |
Collapse
|