Qu GX, Ying ZM, Zhao CC, Yan SG, Cai XZ. Mechanical Properties and Porosity of Acrylic Cement Bone Loaded with Alendronate Powder. Int J Med Sci 2018; 15:1458-1465. [PMID: 30443165 PMCID: PMC6216052 DOI: 10.7150/ijms.27759] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2018] [Accepted: 08/08/2018] [Indexed: 11/05/2022] Open
Abstract
Aseptic loosening is the most common complication of joint replacement. Previous studies showed that acrylic bone cement loaded with a commercially-available alendronate powder (APAC) had good promise against wear debris-mediated osteolysis for prevention of aseptic loosening. The purpose of the present study was to investigate the effect of adding alendronate powder to an acrylic bone cement on quasi-static mechanical properties (namely, compressive strength, compressive modulus, tensile strength, and flexural strength), fatigue life, porosity, and microstructure of the cement. The results showed that adding up to 1 wt./wt.% alendronate powder exerted no detrimental effect on any of the quasi-static mechanical properties. However, the fatigue life of APAC decreased by between ~17% and ~27 % and its porosity increased by between ~ 5-7 times compared with corresponding values for the control cement (no alendronate powder added). Fatigue life was negatively and significantly correlated with porosity. Considering that fatigue life of the cement plays a significant role in joint replacement survival, clinical use of APAC cannot be recommended.
Collapse
Affiliation(s)
- Guo-Xin Qu
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Jiang-Hong Road 1511, Hangzhou, China
| | - Zhi-Min Ying
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Jiang-Hong Road 1511, Hangzhou, China
| | - Chen-Chen Zhao
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Jiang-Hong Road 1511, Hangzhou, China
| | - Shi-Gui Yan
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Jiang-Hong Road 1511, Hangzhou, China
| | - Xun-Zi Cai
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Jiang-Hong Road 1511, Hangzhou, China
| |
Collapse
|
2
|
Sheafi E, Tanner K. Influence of test specimen fabrication method and cross-section configuration on tension–tension fatigue life of PMMA bone cement. J Mech Behav Biomed Mater 2015; 51:380-7. [DOI: 10.1016/j.jmbbm.2015.07.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 07/21/2015] [Accepted: 07/23/2015] [Indexed: 10/23/2022]
|
3
|
Liquid-solid phase transition alloy as reversible and rapid molding bone cement. Biomaterials 2014; 35:9789-9801. [DOI: 10.1016/j.biomaterials.2014.08.048] [Citation(s) in RCA: 72] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Accepted: 08/29/2014] [Indexed: 01/28/2023]
|
4
|
Compressive fatigue properties of a commercially available acrylic bone cement for vertebroplasty. Biomech Model Mechanobiol 2014; 13:1199-207. [DOI: 10.1007/s10237-014-0566-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Accepted: 02/24/2014] [Indexed: 10/25/2022]
|
5
|
Pelletier MH, Waites M, Lau A, Kostiainen M, Bruce WJ, Bertollo N, Walsh WR. Viscosity of Bone Cement Influences Effectiveness of Vacuum Mixing. INT J POLYM MATER PO 2013. [DOI: 10.1080/00914037.2012.670819] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
6
|
Keeling P, Lennon AB, Kenny PJ, O'Reilly P, Prendergast PJ. The mechanical effect of the existing cement mantle on the in-cement femoral revision. Clin Biomech (Bristol, Avon) 2012; 27:673-9. [PMID: 22503808 DOI: 10.1016/j.clinbiomech.2012.02.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2011] [Revised: 02/23/2012] [Accepted: 02/29/2012] [Indexed: 02/07/2023]
Abstract
BACKGROUND Cement-in-cement revision hip arthroplasty is an increasingly popular technique to replace a loose femoral stem which retains much of the original cement mantle. However, some concern exists regarding the retention of the existing fatigued and aged cement in such cement-in-cement revisions. This study investigates whether leaving an existing fatigued and aged cement mantle degrades the mechanical performance of a cement-in-cement revision construct. METHODS Primary cement mantles were formed by cementing a polished stem into sections of tubular steel. If in the test group, the mantle underwent conditioning in saline to simulate ageing and was subject to a fatigue of 1 million cycles. If in the control group no such conditioning or fatigue was carried out. The cement-in-cement procedure was then undertaken. Both groups underwent a fatigue of 1 million cycles subsequent to the revision procedure. FINDINGS Application of a Mann-Whitney test on the recorded subsidence (means: 0.51, 0.46, n=10+10, P=0.496) and inducible displacement (means: 0.38, 0.36, P=0.96) revealed that there was no statistical difference between the groups. INTERPRETATION This study represents further biomechanical investigation of the mechanical behaviour of cement-in-cement revision constructs. Results suggest that pre-revision fatigue and ageing of the cement may not be deleterious to the mechanical performance of the revision construct. Thus, this study provides biomechanical evidence to back-up recent successes with this useful revision technique.
Collapse
Affiliation(s)
- Parnell Keeling
- Cappagh National Orthopaedic Hospital, Finglas, Dublin 11, Ireland.
| | | | | | | | | |
Collapse
|
7
|
Abstract
Acrylic bone cements are in extensive use in joint replacement surgery. They are weight bearing and load transferring in the bone-cement-prosthesis complex and therefore, inter alia, their mechanical properties are deemed to be crucial for the overall outcome. In spite of adequate preclinical test results according to the current specifications (ISO, ASTM), cements with inferior clinical results have appeared on the market. The aim of this study was to investigate whether it is possible to predict the long term clinical performance of acrylic bone cement on the basis of mechanical in vitro testing. We performed in vitro quasistatic testing of cement after aging in different media and at different temperatures for up to 5 years. Dynamic creep testing and testing of retrieved cement were also performed. Testing under dry conditions, as required in current standards, always gave higher values for mechanical properties than did storage and testing under more physiological conditions. We could demonstrate a continuous increase in mechanical properties when testing in air, while testing in water resulted in a slight decrease in mechanical properties after 1 week and then levelled out. Palacos bone cement showed a higher creep than CMW3G and the retrieved Boneloc specimens showed a higher creep than retrieved Palacos. The strength of a bone cement develops more slowly than the apparent high initial setting rate indicates and there are changes in mechanical properties over a period of five years. The effect of water absorption is important for the physical properties but the mechanical changes caused by physical aging are still present after immersion in water. The established standards are in need of more clinically relevant test methods and their associated requirements need better definition. We recommend that testing of bone cements should be performed after extended aging under simulated physiological conditions. Simple quasistatic and dynamic creep tests seem unable to predict clinical performance of acrylic bone cements when the products under test are chemically very similar. However, such testing might be clinically relevant if the cements exhibit substantial differences.
Collapse
Affiliation(s)
- Markus Nottrott
- Centre for Bone- and Soft tissue Tumours, Department of Orthopaedic Surgery, Haukeland University Hospital, NO-5021 Bergen, Norway.
| |
Collapse
|
8
|
Baleani M, Bialoblocka-Juszczyk E, Engels GE, Viceconti M. The effect of vacuum mixing and pre-heating the femoral component on the mechanical properties of the cement mantle. ACTA ACUST UNITED AC 2010; 92:454-60. [PMID: 20190321 DOI: 10.1302/0301-620x.92b3.22579] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
We investigated the effect of pre-heating a femoral component on the porosity and strength of bone cement, with or without vacuum mixing used for total hip replacement. Cement mantles were moulded in a manner simulating clinical practice for cemented hip replacement. During polymerisation, the temperature was monitored. Specimens of cement extracted from the mantles underwent bending or fatigue tests, and were examined for porosity. Pre-heating the stem alone significantly increased the mean temperature values measured within the mantle (+14.2 degrees C) (p < 0.001) and reduced the mean curing time (-1.5 min) (p < 0.001). The addition of vacuum mixing modulated the mean rise in the temperature of polymerisation to 11 degrees C and reduced the mean duration of the process by one minute and 50 seconds (p = 0.01 and p < 0.001, respectively). In all cases, the maximum temperature values measured in the mould simulating the femur were < 50 degrees C. The mixing technique and pre-heating the stem slightly increased the static mechanical strength of bone cement. However, the fatigue life of the cement was improved by both vacuum mixing and pre-heating the stem, but was most marked (+ 280 degrees C) when these methods were combined. Pre-heating the stem appears to be an effective way of improving the quality of the cement mantle, which might enhance the long-term performance of bone cement, especially when combined with vacuum mixing.
Collapse
Affiliation(s)
- M Baleani
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Via Di Barbiano 1/10, 40136, Bologna, Italy.
| | | | | | | |
Collapse
|
9
|
Lewis G, Schwardt JD, Slater TA, Janna S. Evaluation of a synthetic vertebral body augmentation model for rapid and reliable cyclic compression life testing of materials for balloon kyphoplasty. J Biomed Mater Res B Appl Biomater 2008; 87:179-88. [DOI: 10.1002/jbm.b.31089] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
10
|
Evans SL. Fatigue crack propagation under variable amplitude loading in PMMA and bone cement. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2007; 18:1711-7. [PMID: 17483908 DOI: 10.1007/s10856-007-3021-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2005] [Accepted: 05/05/2006] [Indexed: 05/15/2023]
Abstract
Fatigue failure of PMMA bone cement is an important factor in the failure of cemented joint replacements. Although these devices experience widely varying loads within the body, there has been little or no study of the effects of variable amplitude loading (VAL) on fatigue damage development. Fatigue crack propagation tests were undertaken using CT specimens made from pure PMMA and Palacos R bone cement. In PMMA, constant amplitude loading tests were carried out at R- ratios ranging from 0.1 to 0.9, and VAL tests at R = 0.1 with 30% overloads every 100 cycles. Palacos R specimens were tested with and without overloads every 100 cycles and with a simplified load spectrum representing daily activities. The R- ratio had a pronounced effect on crack propagation in PMMA consistent with the effects of slow crack growth under constant load. Single overloads caused pronounced crack retardation, especially at low da/dN. In Palacos R, similar overloads had little effect, whilst individual overloads at low da/dN caused pronounced acceleration and spectrum loading retarded crack growth relative to Paris Law predictions. These results demonstrate that VAL can have dramatic effects on crack growth, which should be considered when testing bone cements.
Collapse
Affiliation(s)
- S L Evans
- School of Engineering, Cardiff University, The Parade, Cardiff, UK.
| |
Collapse
|
11
|
Nicholas MKD, Waters MGJ, Holford KM, Adusei G. Analysis of rheological properties of bone cements. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2007; 18:1407-12. [PMID: 17277981 DOI: 10.1007/s10856-007-0125-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2005] [Accepted: 03/08/2006] [Indexed: 05/13/2023]
Abstract
The rheological properties of three commercially available bone cements, CMW 1, Palacos R and Cemex ISOPLASTIC, were investigated. Testing was undertaken at both 25 and 37 degrees C using an oscillating parallel plate rheometer. Results showed that the three high viscosity cements exhibited distinct differences in curing rate, with CMW 1 curing in 8.7 min, Palacos R and Cemex ISOPLASTIC in 13 min at 25 degrees C. Furthermore it was found that these curing rates were strongly temperature dependent, with curing rates being halved at 37 degrees C. By monitoring the change of viscosity with time over the entire curing process, the results showed that these cements had differing viscosity profiles and hence exhibit very different handling characteristics. However, all the cements reached the same maximum viscosity of 75 x 10(3) Pa s. Also, the change in elastic/viscous moduli and tan delta with time, show the cements changing from a viscous material to an elastic solid with a clear peak in the viscous modulus during the latter stages of curing. These results give valuable information about the changes in rheological properties for each commercial bone cement, especially during the final curing process.
Collapse
Affiliation(s)
- M K D Nicholas
- School of Engineering, Cardiff University, Queen's Buildings, The Parade, Cardiff CF24 3AA, UK.
| | | | | | | |
Collapse
|
12
|
Marrs B, Andrews R, Rantell T, Pienkowski D. Augmentation of acrylic bone cement with multiwall carbon nanotubes. J Biomed Mater Res A 2006; 77:269-76. [PMID: 16392130 DOI: 10.1002/jbm.a.30651] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Acrylic bone cement, based on polymethylmethacrylate (PMMA), is a proven polymer having important applications in medicine and dentistry, but this polymer continues to have less than ideal resistance to mechanical fatigue and impact. A variety of materials have been added to bone cement to augment its mechanical strength, but none of these augmentative materials has proven successful. Carbon nanotubes, a new hollow multiwalled tubular material 10-40 nm in diameter, 10-100 microm long, and 50-100 times the strength of steel at 1/6 the weight, have emerged as a viable augmentation candidate because of their large surface area to volume ratio. The objective of this study was to determine if the addition of multiwall carbon nanotubes to bone cement can alter its static or dynamic mechanical properties. Bar-shaped specimens made from six different (0-10% by weight) concentrations of multiwall carbon nanotubes were tested to failure in quasi-static 3-point bending and in 4-point bending fatigue (5 Hz). Analyses of variance and the 3-Parameter Weibull model were used to analyze the material performance data. The 2 wt % MWNT concentration enhanced flexural strength by 12.8% (p=0.003) and produced a 13.1% enhancement in yield stress (p=0.002). Bending modulus increased slightly with the smaller (<5 wt % MWNT) concentrations, but increased 24.1% (p<0.001) in response to the 10 wt % loading. While the 2 wt % loading produced slightly improved quasi-static test results, it was associated with clearly superior fatigue performance (3.3x increase in the Weibull mean fatigue life). Weibull minimum fatigue life (No), Weibull modulus (alpha), and characteristic fatigue life (beta) for bone cement augmented with carbon nanotubes were enhanced versus that observed in the control group. These data unambiguously showed that the bone cement-MWNT polymer system has an enhanced fatigue life compared to "control" bone cement (no added nanotubes). It is concluded that specific multiwall carbon nanotube loadings can favorably improve the mechanical performance of bone cement.
Collapse
Affiliation(s)
- Brock Marrs
- Center for Biomedical Engineering, University of Kentucky, Washington and Rose Streets, Lexington, Kentucky 40507-0070, USA
| | | | | | | |
Collapse
|
13
|
Evans SL. Effects of porosity on the fatigue performance of polymethyl methacrylate bone cement: an analytical investigation. Proc Inst Mech Eng H 2006; 220:1-10. [PMID: 16459441 DOI: 10.1243/095441105x69024] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Porosity has been shown to affect the fatigue life of bone cements, but, although vacuum mixing is widely used to reduce porosity in the clinical setting, results have been mixed and the effects of porosity are not well understood. The aim of this study was to investigate the effects of porosity using stress analysis and fracture mechanics techniques. The stress concentrations arising at voids in test specimens were found using analytical solutions and boundary element methods. The fatigue life of specimens containing voids of various sizes was predicted using fracture mechanics techniques. For spherical voids that do not occupy a significant proportion of the cross-section, the resulting stress concentration is independent of void size and too small to account for the observed crack initiation. Cracks must therefore initiate at additional stress raisers such as radiopacifier particles or additional voids. For large voids, the stress increases as the remaining cross-section of the specimen decreases, and this may account for much of the observed reduction in fatigue strength in hand-mixed cement. Although crack initiation may be largely independent of void size, there is an effect on crack growth rate. Cracks are predicted to grow faster around larger voids, since they remain in the stress concentration around the void for longer. This effect may account for the relationship between porosity and fatigue life that has been observed in samples without large voids. Since porosity appears to affect crack growth more than initiation, it may be less damaging in high-cycle clinical fatigue, which may be predominantly initiation controlled, than in short laboratory tests.
Collapse
Affiliation(s)
- S L Evans
- School of Engineering, Cardiff University, PO Box 925, The Parade, Cardiff CF24 3AA, UK.
| |
Collapse
|
14
|
Heaton-Adegbile P, Zant NP, Tong J. In vitro fatigue behaviour of a cemented acetabular reconstruction. J Biomech 2006; 39:2882-6. [PMID: 16325188 DOI: 10.1016/j.jbiomech.2005.10.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2005] [Accepted: 10/10/2005] [Indexed: 11/16/2022]
Abstract
In this study, a hemi-pelvis of composite sawbone was implanted with a Charnley cup using a conventional bone cement and the acetabular replacement was tested under constant amplitude cyclic loads, simulating the maximum hip contact force during normal walking. The damage development in the reconstruction was detected and monitored using CT scanning at regular test intervals, verified by microscopy post testing. Three identical experimental results showed that extensive debonding at the bone-cement interface occurred around the dome region after 20 million cycles.
Collapse
Affiliation(s)
- Phillip Heaton-Adegbile
- Department of Mechanical and Design Engineering, University of Portsmouth, Anglesea Road, Anglesea Building, Portsmouth PO1 3DJ, UK
| | | | | |
Collapse
|
15
|
Hendriks JGE, Neut D, Hazenberg JG, Verkerke GJ, van Horn JR, van der Mei HC, Busscher HJ. The influence of cyclic loading on gentamicin release from acrylic bone cements. J Biomech 2005; 38:953-7. [PMID: 15713316 DOI: 10.1016/j.jbiomech.2004.05.018] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/12/2004] [Indexed: 11/16/2022]
Abstract
Antibiotic-loaded acrylic bone cement is widely used in total joint replacement to reduce infections. Walking results in cyclic loading, which has been suggested to stimulate antibiotic release. The goal of this study is to compare antibiotic release from cyclically loaded bone cement with the release from unloaded bone cement. Two models of the frontal aspect of a femoral stem were cemented with CMW 1 Radiopaque G, Palacos R-G and Palamed G. Both were immersed in water, and the gentamicin concentration in the water was monitored. One model was cyclically loaded at 5 Hz during immersion achieving physiological stresses in the bone cement mantle. After 10.8 x 10(6) cycles, initial release of gentamicin from Palamed G was increased significantly for loaded over unloaded, but not from CMW 1 Radiopaque G and Palacos R-G.
Collapse
Affiliation(s)
- Johannes G E Hendriks
- Department of Biomedical Engineering, University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
16
|
Kurtz SM, Villarraga ML, Zhao K, Edidin AA. Static and fatigue mechanical behavior of bone cement with elevated barium sulfate content for treatment of vertebral compression fractures. Biomaterials 2005; 26:3699-712. [PMID: 15621260 DOI: 10.1016/j.biomaterials.2004.09.055] [Citation(s) in RCA: 80] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2004] [Accepted: 09/24/2004] [Indexed: 11/29/2022]
Abstract
The use of bone cement to treat vertebral compression fractures in a percutaneous manner requires placement of the cement under fluoroscopic image guidance. To enhance visualization of the flow during injection and to monitor and prevent leakage beyond the confines of the vertebral body, the orthopedic community has described increasing the amount of radiopacifier in the bone cement. In this study, static tensile and compressive testing, as well as fully reversed fatigue testing, was performed on three PMMA-based bone cements. Cements tested were SimplexP with 10% barium sulfate (Stryker Orthopedics, Mahwah, NJ) which served as a control; SimplexP with 36% barium sulfate prepared according to the clinical recommendation of Theodorou et al.; and KyphX HV-R with 30% barium sulfate (Kyphon Inc., Sunnyvale, CA). Static tensile and compressive testing was performed in accordance with ASTM F451-99a. Fatigue testing was conducted in accordance with ASTM F2118-01a under fully reversed, +/-10-, +/-15-, and +/-20-MPa stress ranges. Survival analysis was performed using three-parameter Weibull modeling techniques. KyphX HV-R was found to have comparable static mechanical properties and significantly greater fatigue life than either of the two control materials evaluated in the present study. The static tensile and compressive strengths for all three PMMA-based bone cements were found to be an order of magnitude greater than the expected stress levels within a treated vertebral body. The static and fatigue testing data collected in this study indicate that bone cement can be designed with barium sulfate levels sufficiently high to permit fluoroscopic visualization while retaining the overall mechanical profile of a conventional bone cement under typical in vivo loading conditions.
Collapse
Affiliation(s)
- S M Kurtz
- Exponent, Inc., 3401 Market Street, Suite 300, Philadelphia, PA 19104, USA.
| | | | | | | |
Collapse
|
17
|
Lewis G, Sadhasivini A. Estimation of the minimum number of test specimens for fatigue testing of acrylic bone cement. Biomaterials 2004; 25:4425-32. [PMID: 15046933 DOI: 10.1016/j.biomaterials.2003.11.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2003] [Accepted: 11/11/2003] [Indexed: 10/26/2022]
Abstract
In the literature on fatigue testing of acrylic bone cements, data sets of various sizes have been used in different test series for the same cement formulation. There are two important consequences of this situation. First, it means that some test series last much longer than others, with all the implications for the cost of testing. Second, it makes drawing conclusions about the fatigue performance of a cement, based on the results of different literature series, a problematic issue. Clearly then, a recommendation as to what should be the minimum number of test specimens to use that would allow for confidence in the results of the statistical treatment of the test results (Gmin) would be desirable. In the present work, a method that could be used to culminate in such a recommendation is described. This method involves (i) obtaining experimental fatigue test results and (ii) analyzing those results using the Weibull probability distribution function and other statistical methods. This methodology is illustrated using fatigue life results obtained from uniaxial tension-compression fatigue tests on specimens fabricated from the polymerizing dough of one commercially available acrylic bone cement. For a tolerable error of 5%, we estimated Gmin to be either 7 (if the fatigue life results are treated using the two-parameter Weibull distribution function) or 11 (if the fatigue life results are treated using the three-parameter Weibull distribution function). To be on the conservative side, we therefore recommend that Gmin be 11. Three key limitations of the methodology presented here are discussed.
Collapse
Affiliation(s)
- Gladius Lewis
- Department of Mechanical Engineering, The University of Memphis, 316 Engineering Science Building, Memphis, TN 38152-3180, USA.
| | | |
Collapse
|
18
|
Deb S, Lewis G, Janna SW, Vazquez B, San Roman J. Fatigue and fracture toughness of acrylic bone cements modified with long-chain amine activators. ACTA ACUST UNITED AC 2003; 67:571-7. [PMID: 14566799 DOI: 10.1002/jbm.a.10065] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The composition of acrylic bone cement has been identified as one of the important parameters affecting its mechanical properties and may, in turn, ultimately influence the longevity of a cemented arthroplasty. Our aim in this study was to determine the influence of change of one compositional variable, the activator, on the fatigue performance and fracture toughness of specimens of the fully cured cement. To that end, three sets of cements were prepared, containing either the conventional activator, 4-N,N dimethyl p-toluidine (DMPT), or novel ones that are tertiary amines based on long-chain fatty acids, that is, 4-N,N dimethylaminobenzyl oleate (DMAO) and 4-N,N dimethylaminobenzyl laurate (DMAL). In the fatigue tests, the specimens were subjected to tension-tension loading, and the results (number of cycles to failure, Nf) were analyzed using the linearized form of the three-parameter Weibull equation. The fracture toughness (KIc) tests were conducted with rectangular compact tension specimens. All fracture surfaces were subsequently examined with scanning electron microscopy. We found that the Weibull mean fatigue lives for specimens fabricated using the DMPT, DMAL, and DMAO containing cements were 272,823, 453,551, and 583,396 cycles, respectively. The corresponding values for KIc were 1.94 +/- 0.05, 2.06 +/- 0.09, and 2.00 +/- 0.07 MPa radical m, respectively. Statistical analyses showed that for both the DMAL- and DMAO-containing cements, the mean values of Nf were significantly higher compared to the corresponding value for the DMPT-containing cement (Mann-Whitney test; alpha < 0.10). This result is attributed to the higher molecular weights of the former cements compared to the latter. The same trend was found for the mean KIc values (Mann-Whitney test; alpha < 0.05), with the trend being explained in terms of the differences seen in the crack morphologies. These results thus demonstrate that these novel amines are viable alternatives to DMPT for incorporation into acrylic bone cement formulations in the future.
Collapse
Affiliation(s)
- S Deb
- Department of Biomaterials, Guy's, King's and St. Thomas' Dental Institute, Floor 17, Guy's Tower, King's College London, London, UK.
| | | | | | | | | |
Collapse
|
19
|
Lewis G. Fatigue testing and performance of acrylic bone-cement materials: state-of-the-art review. J Biomed Mater Res B Appl Biomater 2003; 66:457-86. [PMID: 12808608 DOI: 10.1002/jbm.b.10018] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Over the past three decades or so, a very large volume of literature has been generated on the impact of an assortment of variables on the fatigue lifetimes of a large number of acrylic bone-cement formulations. In the present article, this literature is examined critically to reveal areas of agreement, areas of disagreement, as well as a welter of underexplored and unexplored topics. For example, there is unanimity of support for the notion that an increase in the molecular weight of the powder constituents or the fully cured cement leads to an increase in the cement's fatigue life, whereas there is disagreement as to whether vacuum mixing the cement constituents leads to an increase in the fatigue life of the fully cured cement (relative to the hand-mixed counterpart). Among the underexplored topics is systematic study of the effect of test frequency on the fatigue results, whereas determination of the optimal concentration of the antibiotic in an antibiotic-loaded cement is an example of the unexplored topics. It is pointed out that resolving the controversies, addressing the underexplored topics, and filling the lacunae will allow comprehensive evaluations of acrylic bone-cement materials to be made. This enhanced body of knowledge will prove invaluable in the continued use of acrylic bone cement as the anchoring agent in cemented arthroplasties.
Collapse
Affiliation(s)
- Gladius Lewis
- Department of Mechanical Engineering, The University of Memphis, Memphis, Tennessee 38152, USA.
| |
Collapse
|