1
|
Hodge C, Chan C, Bali SJ, Sutton G. A review of corneal melting following kerato‐refractive surgery. Clin Exp Optom 2021; 96:14-9. [DOI: 10.1111/j.1444-0938.2012.00759.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2012] [Revised: 03/07/2012] [Accepted: 03/14/2012] [Indexed: 12/01/2022] Open
Affiliation(s)
- Christopher Hodge
- Vision Eye Institute, Chatswood, NSW, Australia,
- Sydney Medical School, The University of Sydney, Australia,
| | - Colin Chan
- Vision Eye Institute, Chatswood, NSW, Australia,
- Central Clinical School, The University of Sydney, Australia,
- School of Optometry and Vision Sciences, The University of New South Wales, Australia,
| | | | - Gerard Sutton
- Vision Eye Institute, Chatswood, NSW, Australia,
- Sydney Medical School, The University of Sydney, Australia,
- Central Clinical School, The University of Sydney, Australia,
- Sydney Medical School Foundation, Save Sight Institute, Sydney, NSW, Australia,
| |
Collapse
|
2
|
Abstract
PURPOSE To detect possible differences in clinical outcomes between wavefront-guided laser in situ keratomileusis (LASIK) and wavefront-optimized LASIK for the treatment of myopia. METHODS A comprehensive literature search of Cochrane Library, MEDLINE, and EMBASE to identify relevant trials comparing LASIK with wavefront-guided and wavefront-optimized. A meta-analysis was performed on the results of the reports. Statistical analysis was performed using RevMan 5.0 software. RESULTS Seven articles describing a total of 930 eyes were identified. There were no statistically significant differences in the final proportion of eyes achieving uncorrected distance visual acuity of 20/20 or better [odds ratio, 1.04; 95% confidence interval (CI), 0.66 to 1.65; p = 0.86], manifest refractive spherical equivalent within ± 0.50 D of the target (odds ratio, 0.96; 95% CI, 0.53 to 1.75; p = 0.90). No patient lost ≥ 2 lines of distance-corrected visual acuity at posttreatment. The changes in higher order aberrations were not statistically significant different between the two groups with preoperative root-mean-square (RMS) higher order aberrations <0.3 μm (weighted mean difference, 0.01; 95% CI, -0.02 to 0.04; p = 0.57). However, wavefront-guided had a significant better postoperative aberration profile than wavefront-optimized with preoperative RMS higher order aberrations >0.3 μm (weighted mean difference, -0.10; 95% CI, -0.15 to -0.06; p < 0.00001). CONCLUSIONS Both wavefront-guided and wavefront-optimized LASIK have shown excellent efficacy, safety, and predictability. The wavefront-guided technology may be a more appropriate choice for patients who have preoperative RMS higher order aberrations >0.3 μm.
Collapse
|
3
|
Abstract
PURPOSE OF REVIEW Diffuse lamellar keratitis (DLK) is one of the more common interface complications occurs after laser in-situ keratomileusis (LASIK). The diagnosis can sometimes be challenging, as the differential diagnosis includes infectious keratitis, which requires a completely different treatment compared to DLK. This review assesses our current knowledge of the epidemiology, diagnosis and treatment of DLK. RECENT FINDINGS DLK occurs during the immediate postoperative period, but there are also late-onset cases. Early cases can occur in outbreaks, related to exogenous factors. Late-onset cases are most often related to inciting factors. Over time, case reports and series have reported DLK onset occurring further after surgery. It is probable that additional inciting factors will also be reported over time. Visual outcomes following DLK tend to be good when the condition is diagnosed properly and treated with intensive topical or systemic steroids, possibly combined with interface irrigation. SUMMARY DLK is a well recognized and well described complication occurring after LASIK. Associated inciting and risk factors and treatment algorithms have been described, but additional questions remain. Our knowledge and our patients will benefit from further research and development of evidence-based treatments.
Collapse
Affiliation(s)
- David C Gritz
- Department of Ophthalmology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York 10467, USA.
| |
Collapse
|
4
|
Benito A, Redondo M, Artal P. Temporal evolution of ocular aberrations following laser in situ keratomileusis. Ophthalmic Physiol Opt 2011; 31:421-8. [PMID: 21615763 DOI: 10.1111/j.1475-1313.2011.00854.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE To study the temporal evolution of ocular aberrations after standard LASIK to correct myopia. METHODS The ocular, corneal and internal aberrations for a 6-mm pupil were measured in 22 young myopic eyes (n = 12 subjects; range -2.0 to-7.6 D) before and during a 9-month follow-up after standard myopic LASIK. Ocular aberrations were measured with a Hartmann-Shack wavefront sensor, while corneal aberrations were estimated from the elevation data obtained by corneal topography. For every patient and condition the eye's modulation transfer function (MTF) and Strehl ratio (SR) were calculated. RESULTS Compared to preoperative results, we found that standard myopic LASIK produced a significant increase of ocular high-order aberrations at 1 month after surgery. During the next 8 months, we found a small increase of ocular and corneal positive spherical aberration (SA), although with a large inter-subject variability. However, all eyes treated for myopia higher than -5 D showed a significant increase of positive SA during the first 6 months after surgery. CONCLUSIONS Standard myopic LASIK decreases ocular optical quality. For most subjects, the increase in aberrations induced by the surgery was stable during the next 9 months after LASIK. However, further changes of the ocular SA after myopic LASIK are possible in patients treated for higher amounts of myopia. The changes in aberrations mainly appeared between the first and the sixth month after surgery, which suggests the need to wait at least 6 months after myopic LASIK before comparing outcomes, especially for patients treated for higher myopias.
Collapse
Affiliation(s)
- Antonio Benito
- Laboratorio de Óptica, Departamento de Física, Universidad de Murcia, Murcia, Spain.
| | | | | |
Collapse
|
5
|
Miraftab M, Seyedian MA, Hashemi H. Wavefront-Guided vs Wavefront-Optimized LASIK: A Randomized Clinical Trial Comparing Contralateral Eyes. J Refract Surg 2011; 27:245-50. [DOI: 10.3928/1081597x-20100812-02] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2009] [Accepted: 07/06/2010] [Indexed: 11/20/2022]
|
6
|
Maldonado MJ, Nieto JC, Piñero DP. Advances in technologies for laser-assisted in situ keratomileusis (LASIK) surgery. Expert Rev Med Devices 2008; 5:209-29. [PMID: 18331182 DOI: 10.1586/17434440.5.2.209] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Laser-assisted in situ keratomileusis (LASIK) has become the most widely used form of refractive surgery today. The objective of this surgical technique is to modify the anterior corneal shape by ablating tissue from the stroma by means of the excimer laser after creating a hinged corneal flap. This way, we are able to change the refractive status of the patient, providing better unaided vision. Continuous improvements in the original technique have made the surgical procedure safer, more accurate and repeatable. These progressions are due to the development of novel technologies that are the responsible for new surgical instrumentation, which makes the surgical procedure easier for the surgeon, and better excimer laser ablation algorithms, which increase the optical quality of the ablation and thus the safety of the vision correction procedure. This article aims to describe the more relevant advances in LASIK that have played an important role in the spread and popularity of this technique.
Collapse
Affiliation(s)
- Miguel J Maldonado
- Department of Ophthalmology, Clínica Universitaria, University of Navarra, Avda Pio XII, 36, 31080, Pamplona, Spain.
| | | | | |
Collapse
|
7
|
Kato N, Toda I, Hori-Komai Y, Sakai C, Tsubota K. Five-Year Outcome of LASIK for Myopia. Ophthalmology 2008; 115:839-844.e2. [PMID: 17900692 DOI: 10.1016/j.ophtha.2007.07.012] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2007] [Revised: 06/18/2007] [Accepted: 07/09/2007] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To investigate the efficacy and safety of LASIK over a 5-year postoperative period. DESIGN Observational case series. PARTICIPANTS We examined 779 eyes in 402 patients with myopia or myopic astigmatism who underwent LASIK to correct their refractive errors and received regular postoperative assessments for 5 years. METHODS Postoperative examinations were performed 1 day; 1 week; 1, 3, and 6 months; and 1, 2, 3, 4, and 5 years after LASIK surgery. MAIN OUTCOME MEASURES We evaluated changes in uncorrected visual acuity (UCVA) (logarithm of the minimum angle of resolution [logMAR]), manifest refraction, best-corrected visual acuity (BCVA) (logMAR), intraocular pressure, corneal thickness, corneal endothelial cell counts, and complications. RESULTS Preoperative UCVA of 1.27 improved to -0.03 at 1 day after surgery and -0.08 at 1 month and revealed minimal but significant decreases thereafter. Postoperative manifest refraction was also improved by surgery, showing minimal but significant regression after 1 year. Final BCVA loss was seen in 10 eyes of 7 patients; in 7 cases, there were obvious reasons such as the progression of cataracts in 3 eyes, epithelial disintegrity due to dry eye in 2 eyes, irregular astigmatism due to flap striae in 1 eye, and age-related macular dystrophy in 1 eye. Intraocular pressure and corneal thickness decreased by 4.0 mmHg and 76.9 microm, respectively, due to surgery, but remained stable throughout the follow-up period. Corneal endothelial cell counts (2689.0+/-232.9 cells/mm(2) before surgery) showed a statistically significant decrease at 5 years after surgery (2658.0+/-183.1 cells/mm(2); 1.2% loss for 5 years), likely within the range due to physiological age-related loss. No serious, vision-threatening, irreversible complication such as keratectasia or progressive endothelial cell loss was observed. CONCLUSION LASIK surgery is an effective and safe procedure for correcting myopia/myopic astigmatism as long as inclusion and exclusion criteria are strictly respected. However, minimal regression occurred during the 5-year investigative period.
Collapse
Affiliation(s)
- Naoko Kato
- Minamiaoyama Eye Clinic, Tokyo, Japan.; Department of Ophthalmology, School of Medicine, Keio University, Tokyo, Japan.
| | | | | | | | | |
Collapse
|
8
|
Dai GM, Gross E, Liang J. System performance evaluation of refractive surgical lasers: a mathematical approach. APPLIED OPTICS 2006; 45:2124-34. [PMID: 16579583 DOI: 10.1364/ao.45.002124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
A study was conducted for the purpose of improving the designs of the next generation of refractive surgical laser systems. Two common refractive laser systems, variable-spot scanning (type A) and small-spot scanning (type B), are discussed by identifying sources of error that could adversely affect the capability of these lasers to accurately produce complex, customized wavefront guided ablations. A mathematical model was used to construct a laser simulator that models the two common laser systems in terms of the root-mean-square error. Error sources from ablation profile fitting, ablation registration, eye tracking, and the laser delivery system are compared, and the relative contribution of each to the overall system error is analyzed. This system-level analysis can be helpful to the improvement of both laser systems.
Collapse
|
9
|
Ambati BK, Higgins E, Gupta N, Hu G, Kim T, Carlson AN, Ambati J. Eyelid disease. Ophthalmology 2005; 112:2052-3. [PMID: 16271321 DOI: 10.1016/j.ophtha.2005.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2005] [Accepted: 08/11/2005] [Indexed: 11/24/2022] Open
|
10
|
Abstract
PURPOSE To prospectively evaluate a new high-speed, small spot-scanner laser for the correction of myopia and myopic astigmatism. METHODS Seventy-six consecutive eyes with myopia and myopic astigmatism between -1.00 and -8.25 diopters (D) and up to -2.75 D astigmatism underwent LASIK treatment using the MEL 80 laser (Carl Zeiss Meditec, Jena, Germany). Parameters evaluated were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), residual refractive error, regression of correction, and aberrometry. RESULTS Mean preoperative BSCVA was 20/20, which improved to 20/18 postoperatively. Postoperative UCVA was 20/20 at 1 month and 20/18 at 1 year. Uncorrected visual acuity > or = 20/20 was achieved in 58 (83%) of 70 eyes at 1 month and in 60 (88%) of 68 eyes at 1 year. The average refractive error before LASIK was -4.41 +/- 1.98 D. The mean residual refractive error was 0.14 +/- 0.31 D at 1 month and 0.13 +/- 0.30 D at 1 year. At 1-month and 1-year follow-up, respectively, 66 (94%) of 70 eyes and 65 (96%) of 68 eyes were within +/- 0.50 D of intended refractive correction. No eye lost two lines. At 1 month 17% of eyes and at 1 year 13% of eyes gained two lines or more. Between 1-month and 1-year follow-up, 100% of eyes were stable. Mean root-mean-square high order aberration changed from 0.20 microm preoperatively to 0.28 microm postoperatively. CONCLUSIONS The MEL 80 is effective and safe in the treatment of myopia and myopic astigmatism.
Collapse
|
11
|
Aguirre Rodríguez J, Carreras Egaña I. El médico de familia y la microcirugía ocular (LASIK). Semergen 2005. [DOI: 10.1016/s1138-3593(05)72914-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
12
|
|
13
|
Kohnen T, Bühren J, Kühne C, Mirshahi A. Wavefront-guided LASIK with the Zyoptix 3.1 system for the correction of myopia and compound myopic astigmatism with 1-year follow-up. Ophthalmology 2004; 111:2175-85. [PMID: 15582071 DOI: 10.1016/j.ophtha.2004.06.027] [Citation(s) in RCA: 123] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2004] [Accepted: 06/22/2004] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE To assess safety, efficacy, predictability, stability, and change in aberrations after wavefront-guided LASIK for myopia and myopic astigmatism. DESIGN Prospective, nonrandomized, self-controlled trial. PARTICIPANTS Wavefront-guided LASIK was performed in 97 eyes in a 1-year trial. Treated eyes had a mean subjective manifest spherical equivalent (SE) of -5.22+/-2.07 diopters (D), with a range of -0.25 to -9.00 D of myopia and 0 to -3.25 D of astigmatism. INTERVENTION After a microkeratome cut, a wavefront-based excimer ablation (Zyoptix 3.1) was performed. The full treatment to achieve emmetropia of an early nomogram provided by the system manufacturer was used in all procedures. MAIN OUTCOME MEASURES Safety, efficacy, predictability, and stability were evaluated at 1, 3, and 12 months postoperatively. Wavefront changes of higher order aberrations (HOAs) at 1 year were determined for pupil sizes of 3.5 and 6 mm. RESULTS At 1 year postoperatively, uncorrected visual acuity (VA) was 20/20 or better in 83% of the eyes, and 20/40 or better in 98%. The mean subjective manifest SE at 1 year was -0.25+/-0.43 D; it was within 0.50 D in 77% and within 1.0 D in 95%. No eye lost > or =2 lines of best spectacle-corrected VA (BSCVA) at 1 year postoperatively; 40 eyes gained 1 line of BSCVA, and 5 eyes gained 2 lines. The total HOA root mean square (RMS) increased on average by a factor of 1.23+/-0.57 with a 3.5-mm pupil; for the 6 mm pupil, the increase factor was 1.52+/-0.36. No change or reduction in the total HOA RMS was observed in 45.5% of the eyes for a 3.5-mm pupil and in 20.6% for a 6-mm pupil. There was a significant increase of primary spherical aberration (Z 4,0) by a factor of 4.11+/-10.17 for 3.5-mm pupils and 4.31+/-6.76 for 6-mm pupils. CONCLUSIONS Wavefront-guided LASIK using Zyoptix 3.1 is an effective and safe procedure for the treatment of myopia and myopic astigmatism. Although in close to half of the eyes HOAs could be reduced, there was still undercorrection and induction of HOAs with the algorithm employed.
Collapse
Affiliation(s)
- Thomas Kohnen
- Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany.
| | | | | | | |
Collapse
|
14
|
Kohnen T, Bühren J. [Current state of wavefront guided corneal surgery to correct refraction disorders]. Ophthalmologe 2004; 101:631-45; quiz 646-7. [PMID: 15260018 DOI: 10.1007/s00347-004-1029-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The present review describes the current status of wavefront-guided corneal surgery and up-to-date results. Wavefront-guided LASIK procedures performed to date achieved uncorrected vision of i.o or better in a larger number of patients than with conventional LASIK surgery, but the "eagle eye" has remained the exception. In part of the patients reductions of higher order aberrations could be obtained, but in the majority of ca-ses an increase was observed. This increase was however less than with conventional LASIK surgery. Correction of higher order aberrations has not yet been perfected since the predictability of corrections appears to be deserving of improvement on the one hand and aberrations are still induced by the technique on the other hand.
Collapse
Affiliation(s)
- T Kohnen
- Klinik für Augenheilkunde der Johann Wolfgang Goethe-Universität Frankfurt am Main.
| | | |
Collapse
|
15
|
Brown SM, Khanani AM, McCartney DL. The effect of daily use of brimonidine tartrate on the dark-adapted pupil diameter. Am J Ophthalmol 2004; 138:149-51. [PMID: 15234301 DOI: 10.1016/j.ajo.2004.02.017] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2003] [Accepted: 02/09/2004] [Indexed: 11/27/2022]
Abstract
PURPOSE To investigate the effect of daily brimonidine tartrate 0.15% on the dark-adapted pupil diameter. DESIGN Observational case series. METHOD Ten normal volunteers administered brimonidine to their right eyes once daily. Four to six hours later, infrared pupil photographs were taken after dark adaptation. Measurements were performed at baseline; on treatment days 1, 5, 11, and 18; and on washout days 1 and 2. RESULTS One subject had no response. The nine responding subjects showed an average maximum antimydriatic effect of -1.63 mm (range, -0.57 mm--2.30 mm); all subjects experienced tachyphylaxis. Five subjects showed rebound mydriasis (mean maximum rebound +0.87 mm larger than baseline; range 0.50 mm-1.22 mm). The untreated pupil also responded, showing antimydriasis (two subjects), rebound mydriasis (two subjects), or paradoxical direct mydriasis (one subject). CONCLUSIONS Once-daily use of brimonidine tartrate to prevent dark-induced pupil dilation can lead to tachyphylaxis and rebound mydriasis.
Collapse
Affiliation(s)
- Sandra M Brown
- Department of Ophthalmology and Visual Sciences, Texas Tech University Health Sciences Center, 3601 Fourth Street, Lubbock, TX 79430-7217, USA.
| | | | | |
Collapse
|
16
|
Kim TI, Yang SJ, Tchah H. Bilateral Comparison of Wavefront-guided Versus Conventional Laser in situ Keratomileusis With Bausch and Lomb Zyoptix. J Refract Surg 2004; 20:432-8. [PMID: 15523953 DOI: 10.3928/1081-597x-20040901-04] [Citation(s) in RCA: 80] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE One aim of corneal refractive surgery is to correct defocus and astigmatism. In the process of correcting lower order aberrations, higher order ocular aberrations increase. To evaluate the effectiveness of wavefront-guided laser in situ keratomileusis (LASIK) in reducing the increase of higher order aberration, we compared aberrational change after LASIK with conventional and wavefront-guided customized ablation. METHODS Our study included 48 eyes of 24 patients. We performed conventional LASIK in one eye (Group 1) and wavefront-guided customized ablation in the other eye (Group 2). Ocular aberration was measured with the Zywave, a type of Shack-Hartmann aberrometer. We then compared low and high order aberrations, contrast sensitivity, visual acuity, corneal topography, and manifest refraction preoperatively and postoperatively at 1 and 3 months. RESULTS Uncorrected visual acuity improved to more than 20/20 in two eyes in the conventional ablation group and in five eyes in the customized ablation group. In the conventional ablation group, Root-mean-square for higher order (RMS(H)) was 0.215 preoperatively, 0.465 (216.3%) at 1 month, and 0.418 (194.4%) at 3 months. In the customized ablation group, RMS(H) was 0.207 preoperatively, 0.380 (183.6%) at 1 month, and 0.371 (179.2%) at 3 months after LASIK. Mesopic contrast sensitivity in the customized ablation group was higher than that in the conventional ablation group, but this change was not statistically significant. CONCLUSIONS Wavefront-guided customized ablation reduced the increase of high order aberrations resulting from LASIK. In terms of visual acuity, patient preference, and mesopic contrast sensitivity, wavefront-guided customized ablation produced slightly-but not statistically significant-better results.
Collapse
Affiliation(s)
- Tae-im Kim
- Department of Ophthalmology, College of Medicine, University of Ulsan, Asan Medical Center, Seoul, Korea
| | | | | |
Collapse
|
17
|
Wachler BSB, Hiatt JA. Understanding Pre-market Approval and Labeling Differences of Two Leading Customized Ablation Platforms: A Call for Reform at the FDA. J Refract Surg 2004. [DOI: 10.3928/1081-597x-20040901-34] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
18
|
|
19
|
Giaconi JA, Manche EE. Ablation centration in myopic laser in situ keratomileusis. comparing the Visx S3 ActiveTrak and the Visx S2. J Cataract Refract Surg 2003; 29:1522-9. [PMID: 12954299 DOI: 10.1016/s0886-3350(03)00222-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
PURPOSE To compare ablation centration and outcome measurements in myopic laser in situ keratomileusis (LASIK) using the eye-tracking Visx S3 ActiveTrak and the nontracking Visx S2 excimer lasers. SETTING University-based refractive surgery practice. METHODS In a retrospective study, 71 consecutively treated myopic eyes that had LASIK with the Visx Star S3 ActiveTrak were compared to 71 control-matched eyes treated with the Visx Star S2 without pupil tracking. Primary outcome variables including ablation centration, uncorrected visual acuity, best spectacle-corrected visual acuity, manifest refraction, complications, and induced cylinder analyzed by vector analysis were evaluated 3 months postoperatively. RESULTS The myopia ranged from -1.50 to -11.25 diopters (D) and the cylinder, from +0.25 to +2.75 D. Ninety-four of 142 eyes (66%) were available for analysis at 3 months; 50 eyes could be used to analyze ablation centration. At 3 months, the mean decentration of the ablation zone from the entrance pupil was 0.22 mm +/- 0.20 (SD) in tracked eyes (n = 25) and 0.21 +/- 0.26 mm in nontracked eyes (n = 25) (P =.88). Three eyes (12%) in the tracked group were decentered 0.5 to 1.0 mm, and 1 eye (4%) in the nontracked group was decentered more than 1.0 mm. All other eyes were decentered less than 0.5 mm. There was an association in the tracked group between greater decentrations and higher levels of myopia (r = 0.67), but this association did not exist in the nontracked group (r = -0.03). CONCLUSION Comparable ablation centration as well as visual and refractive outcomes can be achieved with and without active eye tracking during myopic and astigmatic myopic LASIK.
Collapse
Affiliation(s)
- JoAnn A Giaconi
- Department of Ophthalmology, Stanford University, Stanford, California 94305, USA
| | | |
Collapse
|
20
|
Hardten DR, Hauswirth SG. Comparison of designs of laser systems utilized for refractive surgery. Curr Opin Ophthalmol 2003; 14:213-9. [PMID: 12888720 DOI: 10.1097/00055735-200308000-00008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Several different laser types are available on the market for the practitioner to use in refractive surgery. Each laser type has certain parameters that the surgeon must understand to obtain the best refractive outcomes. Studies published in peer-reviewed literature between February 2002 and March 2003 show that refractive results across all types of lasers have improved compared with those of several years ago. A difference in refractive outcomes between lasers is impossible to directly compare, as there are no randomized studies that hold surgeon or patient characteristics constant.
Collapse
Affiliation(s)
- David R Hardten
- Minnesota Eye Consultants, P.A. 710 East 24th Street, Suite 106, Minneapolis, MN 55404, USA.
| | | |
Collapse
|