1
|
Abdel-Radi M, Rateb M, Saleh MGA, Aly MOM. Twelve-month outcomes of single-step transepithelial photorefractive keratectomy for moderate hyperopia and hyperopic astigmatism. EYE AND VISION (LONDON, ENGLAND) 2023; 10:7. [PMID: 36855211 PMCID: PMC9976533 DOI: 10.1186/s40662-023-00327-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 01/08/2023] [Indexed: 03/02/2023]
Abstract
BACKGROUND Conventional mechanical or alcohol-assisted photorefractive keratectomy (PRK) techniques for correction of hyperopia and hyperopic astigmatism were associated with inconsistent results. The aim of this study is to evaluate the 12-month visual and refractive outcomes of the relatively new single-step transepithelial photorefractive keratectomy (TE-PRK) for moderate hyperopia and hyperopic astigmatism. METHODS This is a prospective interventional study. Forty-eight eyes of 30 patients with moderate hyperopia or hyperopic astigmatism with a cycloplegic spherical equivalent refraction (SEQ) between 2.0 and 4.5 diopters (D) underwent single-step StreamLight® TE-PRK using EX500 excimer laser (Alcon Laboratories, USA). The main outcome measures were recorded at 6 and 12 months postoperatively including assessment of logarithm of the minimum angle resolution (logMAR) uncorrected and corrected distance visual acuity (UDVA, CDVA), cycloplegic refraction, corneal topographic changes as well as post-PRK peripheral haze grading. RESULTS The mean preoperative cycloplegic SEQ was significantly reduced from 3.21 ± 0.61 D to 0.35 ± 0.04 D and 0.41 ± 0.04 D at 6 and 12 months, respectively (P < 0.001). The mean preoperative UDVA significantly improved from 0.53 ± 0.02 logMAR to 0.07 ± 0.01 logMAR and 0.08 ± 0.01 logMAR at 6 and 12 months, respectively (P < 0.001) while the mean preoperative logMAR CDVA showed non-significant change over time throughout the study (P = 0.135). At the end of the study, 41 eyes (85.4%) achieved UDVA of 20/25 or better and no eye lost any lines of CDVA. Thirty-eight eyes (79.1%) had a postoperative cycloplegic cylinder of 0.5 D or less at 12 months. The mean preoperative mean keratometry showed significant increase at 6 and 12 months postoperatively (P < 0.001) while there was no significant change between the two postoperative visits denoting topographic stability (P = 0.058). The mean postoperative Q value at 6 and 12 months showed a significant prolate shift (P < 0.001). No haze was observed in 62.5% and 85.4% of the enrolled eyes at 6 and 12 months, respectively. CONCLUSIONS Single-step StreamLight® TE-PRK for moderate hyperopia and hyperopic astigmatism achieved acceptable visual and refractive outcomes. TRIAL REGISTRATION (Clinicaltrials.gov): NCT05261685, 2 March 2022, retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT05261685.
Collapse
Affiliation(s)
- Mahmoud Abdel-Radi
- Department of Ophthalmology, Assiut University, Assiut University Hospital, 6th Floor, 71516, Assiut, Egypt.
| | - Mahmoud Rateb
- grid.411437.40000 0004 0621 6144Department of Ophthalmology, Assiut University, Assiut University Hospital, 6th Floor, 71516 Assiut, Egypt
| | - Mohamed G. A. Saleh
- grid.411437.40000 0004 0621 6144Department of Ophthalmology, Assiut University, Assiut University Hospital, 6th Floor, 71516 Assiut, Egypt
| | - Mohamed Omar M. Aly
- grid.411437.40000 0004 0621 6144Department of Ophthalmology, Assiut University, Assiut University Hospital, 6th Floor, 71516 Assiut, Egypt
| |
Collapse
|
2
|
Adib-Moghaddam S, Arba-Mosquera S, Walter-Fincke R, Soleyman-Jahi S, Adili-Aghdam F. Transepithelial Photorefractive Keratectomy for Hyperopia: A 12-Month Bicentral Study. J Refract Surg 2016; 32:172-80. [PMID: 27027624 DOI: 10.3928/1081597x-20160121-01] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Accepted: 12/03/2015] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate the safety, efficacy, and stability of transepithelial photorefractive keratectomy (PRK) for hyperopia. METHODS This interventional case series study at two sites included 55 eyes (31 patients) with hyperopia (0.50 to 6.00 diopters [D]), with or without astigmatism (0.00 to -3.00 D), that underwent one-step transepithelial PRK with a Amaris 500-Hz excimer laser (SCHWIND eye-tech-solutions, Kleinostheim, Germany). A 12-month follow-up was conducted. Preoperative and successive postoperative visual acuity, manifest refraction, haze, and other complication data were analyzed. RESULTS The preoperative mean spherical equivalent of 2.56 ± 1.90 D improved to emmetropia (-0.08 ± 0.14 D) by 6 months, with subsequent slight mean regression of 0.024 D (range: -0.75 to 0.50) until month 12. Of the treated eyes, 75% and 76.2% were within the target refraction of ±0.50 D at 6 and 12 months postoperatively, respectively. The final mean cylindric refraction was comparable to the preoperative value (-0.94 ± 0.12 to -0.71 ± 0.12 D, P = .17); however, it was induced in 23% of eyes. The preoperative mean uncorrected distance visual acuity logMAR of 0.54 ± 0.05 significantly improved to 0.15 ± 0.03 by month 12 (P < .0001), and 64.2% of the treated eyes gained an uncorrected distance visual acuity of 20/25 or better. Ten eyes (23.8%) lost one line of preoperative corrected distance visual acuity (CDVA). No eye lost two or more lines of preoperative CDVA. Four eyes with a 3+ degree of haze were observed by the final visit. No other notable complications occurred. The low hyperopic eyes exhibited better overall results compared to the moderate hyperopic group. CONCLUSIONS One-step transepithelial PRK with the Amaris 500-Hz excimer laser provided reasonable outcomes for the correction of hyperopia with or without mild to moderate astigmatism.
Collapse
|
3
|
Eighteen-year follow-up of hyperopic photorefractive keratectomy. J Cataract Refract Surg 2016; 42:258-66. [DOI: 10.1016/j.jcrs.2015.09.025] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2015] [Revised: 08/17/2015] [Accepted: 09/09/2015] [Indexed: 11/19/2022]
|
4
|
Abstract
The use of a large apex-angle axicon for common-path interferometric wavefront sensing is proposed. The approach is a variant of point-diffraction interferometry bearing similarities to pyramidal wavefront sensing. A theoretical basis for wavefront sensing with an axicon is developed, and the outcomes of numerical simulations are compared to experimental results obtained with spherical and cylindrical ophthalmic trial lenses. It is confirmed that the axicon can be used for wavefront sensing, although its refraction may ultimately complicate and limit its operational range.
Collapse
Affiliation(s)
- Brian Vohnsen
- School of Physics, University College Dublin, Dublin, Ireland.
| | | | | |
Collapse
|
5
|
O'Brart DPS, Mellington F, Jones S, Marshall J. Laser Epithelial Keratomileusis for the Correction of Hyperopia Using a 7.0-mm Optical Zone With the Schwind ESIRIS Laser. J Refract Surg 2007; 23:343-54. [PMID: 17455829 DOI: 10.3928/1081-597x-20070401-06] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate the efficacy of laser epithelial keratomileusis (LASEK) for the correction of hyperopia using a 7.0-mm optical zone and a 9.0-mm total ablation zone diameter with the Schwind ESIRIS flying-spot laser. METHODS Forty-seven patients (70 eyes) were treated with a mean preoperative spherical equivalent refraction of +2.32 diopters (D) (range: 0 to +5.00 D). All eyes underwent LASEK using 15% alcohol with a 20-second application. RESULTS An intact epithelial flap was obtained in 66 (94%) eyes. In 70 eyes at 12 months, the mean spherical equivalent refraction was +0.09 D (range: -0.75 to +1.00 D) with all (100%) eyes within +/- 1.00 D of the intended correction and 60 (86%) eyes within +/- 0.50 D. In 40 eyes with 24-month follow-up, the refractive correction remained stable after 6 months. Hyperopic cylindrical corrections were attempted in 49 eyes (range: +0.25 to +5.00 D) with vector analysis demonstrating a mean 102% correction at 12 to 24 months. In 60 non-amblyopic eyes, uncorrected visual acuity was > or = 20/20 in 47 (78%) eyes. Thirty-three (47%) eyes gained 1 to 2 lines of Snellen decimal equivalent best spectacle-corrected visual acuity, 30 (43%) eyes showed no change, and 7 (10%) eyes lost 1 line. Eight (11%) eyes at 12 to 24 months had grade +/- 1 of paracentral corneal haze and 57 (81%) had no haze. At 12 months (n = 70), the safety index was 1.06 with an efficacy index of 0.95. Analysis of higher order wavefront aberrations showed no significant changes in root-mean-square values post-operatively, except for a significant reduction of fourth order spherical aberration (P < .05). CONCLUSIONS Laser epithelial keratomileusis for hyperopia up to +5.00 D using a 7.0-mm optical zone with the Schwind ESIRIS laser provides excellent refractive and visual outcomes with minimal complications. In eyes followed for 24 months, the refractive correction remained stable after 6 months.
Collapse
Affiliation(s)
- David P S O'Brart
- Department of Ophthalmology, St Thomas' Hospital, London, United Kingdom.
| | | | | | | |
Collapse
|
6
|
Abstract
Surgical attempts to correct hyperopia have yielded varying results over the last 130 years. These techniques include the reshaping of the cornea through incisions, burns, or lamellar cuts with removal of peripheral tissue; the addition of central inlays; laser ablations; and the replacement of the crystalline lens. By examining the success of each surgical technique, the refractive surgeon may be able to make an informed decision on its indications and limitations, based on the specific patient's characteristics. Reporting the outcomes and complications of hyperopic surgery will help refine our approach to the management of an increasingly hyperopic and presbyopic population.
Collapse
Affiliation(s)
- Salomon Esquenazi
- LSU Eye Center and LSU Neuroscience Center, Louisiana State University Health Sciences Center, New Orleans, USA.
| | | | | |
Collapse
|
7
|
O'Brart DPS, Al-Attar M, Hussein B, Angunawela R, Marshall J. Laser Subepithelial Keratomileusis for the Correction of High Myopia With the Schwind ESIRIS Scanning Spot Laser. J Refract Surg 2006; 22:253-62. [PMID: 16602314 DOI: 10.3928/1081-597x-20060301-10] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate the efficacy of laser subepithelial keratomileusis (LASEK) for the correction of high myopia with the Schwind ESIRIS scanning spot laser (Schwind eye-tech-solutions Gmbh & Co, Kleinostheim, Germany). METHODS Fifty-one patients (76 eyes) were treated with a mean preoperative spherical equivalent refraction of -7.55 diopters (D) (range: -6.0 to -10.75 D). All eyes received a LASEK technique using 15% alcohol with a 20-second application. RESULTS An intact epithelial flap was obtained in 73 (96%) eyes. At 1 week, uncorrected visual acuity (UCVA) was > or =20/30 in 53 (70%) eyes and > or =20/60 in all eyes. At 6 months (n=76), the mean SE was +0.08 D (range: -1.00 to +1.875 D) with 73 (96%) eyes within +/-1.0 D of the intended correction and 60 (79%) eyes within +/-0.5 D. At 12 months (n=46), the mean SE was -0.07 D (range: -1.375 to +2.0 D) with 44 (96%) eyes within +/-1.0 D of the intended correction and 37 (80%) eyes within +/-0.5 D. Myopic cylindrical corrections were attempted in 68 eyes (range: -0.25 to -4.25 D) with vector analysis demonstrating a mean 85% correction. At last follow-up, UCVA was > or =20/20 in 47 (62%) eyes, > or =20/25 in 63 (83%) eyes, and > or =20/40 in 75 (99%) eyes. Three (4%) eyes gained two lines of Snellen decimal equivalent best spectacle-corrected visual acuity compared to preoperative levels, 68 (89%) eyes showed no change or gained one line, and 5 (7%) eyes lost one line. None lost more than one line. Only 2 (3%) eyes at 6 to 12 months had more than +1 axial corneal haze and 50 (66%) showed no evidence of haze on slit-lamp examination. CONCLUSIONS Laser subepithelial keratomileusis for myopia up to -11.00 D with the Schwind ESIRIS laser provides good refractive and visual outcomes, with acceptable visual recovery and minimal complications.
Collapse
Affiliation(s)
- David P S O'Brart
- Department of Ophthalmology, St Thomas' Hospital, London, United Kingdom.
| | | | | | | | | |
Collapse
|
8
|
O'Brart DPS, Patsoura E, Jaycock P, Rajan M, Marshall J. Excimer laser photorefractive keratectomy for hyperopia: 7.5-year follow-up. J Cataract Refract Surg 2005; 31:1104-13. [PMID: 16039483 DOI: 10.1016/j.jcrs.2004.10.051] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/13/2004] [Indexed: 11/21/2022]
Abstract
PURPOSE To report the results of a long-term prospective study to evaluate refractive stability and safety of hyperopic photorefractive keratectomy (H-PRK). SETTING Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom. METHODS Twenty-one patients (49%) (40 eyes) of cohort of 43 patients who participated in 1 of the first clinical trials of H-PRK were assessed at a mean follow-up of 90.7 months (range 62 to 106 months). The H-PRK was performed using a Summit Technology Apex Plus Excimer laser (Summit Technology, Inc.). The mean preoperative spherical equivalent refraction (SEQ) was +4.70 diopters (D) (range +2.00 to +7.50 D). Patients were allocated to 1 of 4 treatment groups based on their preoperative refraction and received 1 of the following spherical corrections: +1.50 D, +3.00 D, +4.50 D, or +6.00 D. RESULTS At 7.5 years, the refractive correction remained stable with a mean difference in SEQ between 1 year and 7.5 years of +0.28 D. The mean manifest SEQ was +0.83 D (range +5.00 to -3.00 D). Sixty-seven percent of eyes having corrections of +1.50 D and +3.00 D were within +/-1.00 D of the predicted correction. Predictability was poorer with +4.50 D and +6.00 D corrections, with 40% of eyes within +/-1.00 D of that expected. An improvement in uncorrected near acuity was achieved in 35 eyes (87.5%), and 35 eyes (87.5%) showed an improvement in uncorrected distance acuity from preoperative levels. Best spectacle-corrected visual acuity (BSCVA) was unchanged or improved from preoperative values in 25 eyes (62.5%). Three eyes (8%) lost 2 lines of Snellen BSCVA, which in 2 cases was attributable to cataract formation. A peripheral ring of haze, 6.5 mm in diameter, appeared in most eyes. Its intensity was greatest at 6 months and then diminished with time. In 10 eyes (25%), remnants of the haze ring were evident at 7.5 years and subepithelial iron rings, 6.5 mm in diameter were evident in 26 eyes (70%). No patient complained of night-vision problems and no eye developed ectasia. CONCLUSIONS In H-PRK, refractive stability achieved at 1 year was maintained up to 7.5 years with no evidence of hyperopic shift, diurnal fluctuation, or late regression. Peripheral corneal haze decreased with time but was still evident in a number of eyes at the last follow-up visit.
Collapse
Affiliation(s)
- David P S O'Brart
- Department of Ophthalmology, St. Thomas' Hospital, London SE1 7EH, UK.
| | | | | | | | | |
Collapse
|
9
|
Jaycock PD, O'Brart DPS, Rajan MS, Marshall J. 5-year follow-up of LASIK for hyperopia. Ophthalmology 2005; 112:191-9. [PMID: 15691550 DOI: 10.1016/j.ophtha.2004.09.017] [Citation(s) in RCA: 96] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2004] [Accepted: 09/02/2004] [Indexed: 11/19/2022] Open
Abstract
PURPOSE To assess the long-term efficacy and stability of LASIK for hyperopia (+0.75 to +7.00 diopters [D]). DESIGN Retrospective follow-up study of a previous phase III multicenter clinical trial (unpublished data). PARTICIPANTS Patients who had been treated for hyperopia (33 individuals, 47 eyes) attended follow-up 5 years after surgery. The preoperative mean spherical equivalent at the spectacle plane was +3.58 D (range, +0.75 to 7.00 D), and the attempted mean spherical correction at the corneal plane was +3.18 D (range, +1.00 to +6.00 D). INTERVENTION Treatments were performed using a Moria LSK One microkeratome and a Summit Technology SVS Apex Plus excimer laser fitted with an Axicon. MAIN OUTCOME MEASURES Manifest refraction, uncorrected visual acuity, best spectacle-corrected visual acuity, corneal transparency, complications, and patient satisfaction were recorded. RESULTS At 5 years, for treatments between +1.00 to +3.00 D, 71.0% of eyes were within +/-1.00 D of the intended correction, and for treatments between +3.5 to +6.0 D, 37.5% of eyes were within +/-1.00 D of intended correction. From 12 to 54 months after surgery for all patients, there was a hyperopic shift of +0.53 D (range, -0.13 to +3.13 D), with 51.1% of eyes experiencing an increase of +0.50 D or more and 27.7% of eyes showing a hyperopic shift of more than +1.00 D. This hyperopic shift was +0.67 D (range, 0 to +1.125 D) for patients younger than 40 years of age and +0.44 D (range, -1.33 to +1.50 D) for patients between 43 and 55 years of age. CONCLUSIONS LASIK was moderately effective for the correction of low degrees of hyperopia. However, there was regression throughout the 5-year follow-up that was greater than would be expected as a result of aging. Long-term stability of hyperopic LASIK refractive corrections, therefore, is uncertain.
Collapse
Affiliation(s)
- Philip D Jaycock
- Rayne Institute, Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom
| | | | | | | |
Collapse
|
10
|
Lin DY, Manche EE. Two-year results of conductive keratoplasty for the correction of low to moderate hyperopia. J Cataract Refract Surg 2003; 29:2339-50. [PMID: 14709295 DOI: 10.1016/j.jcrs.2003.09.022] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the 2-year postoperative safety, efficacy, predictability, and stability results of conductive keratoplasty (CK) to correct low to moderate hyperopia. SETTING Department of Ophthalmology, Stanford University Medical Center, Stanford, California, USA. METHODS In a prospective nonrandomized noncontrolled trial, 25 eyes of 14 patients with +0.75 to +3.00 diopters (D) of hyperopia and </=0.75 D of cylinder were treated with CK. Low-energy, radio-frequency current was applied to the peripheral corneal stroma through a probe inserted at 8 to 32 treatment spots. An early nomogram was used in 2 eyes, and a current nomogram was used in 23 eyes; the intended refraction was plano. The 23 eyes treated with the current nomogram were analyzed for efficacy, predictability, and stability. All 25 eyes were included in the safety and patient-satisfaction analyses. RESULTS Preoperatively, the mean manifest refraction spherical equivalent (MRSE) in the 23 current-nomogram eyes was +1.55 D. At 2 years, the uncorrected visual acuity was 20/20 or better in 64% of eyes and 20/40 or better in 95%. The MRSE was within +/-0.50 D in 64% of eyes, within +/-1.00 D in 91%, and within +/-2.00 D in 100%. No eye lost more than 1 line of best spectacle-corrected visual acuity or had an induced cylinder greater than 0.75 D. The mean MRSE of the cohort with all follow-ups was +0.48 D, which reflected a 29% regression from the intended plano and 43% regression from the 1-month postoperative overcorrection. The rate of regression appeared to be low and decreasing, +0.024 D per month between 12 and 24 months. A patient survey revealed improved quality of vision and a high level of satisfaction. CONCLUSIONS Conductive keratoplasty appeared to be safe, effective, and predictable for correcting low to moderate hyperopia. Mild hyperopic regression was observed; however, the rate of regression indicated by the mean change in MRSE per month was low and decreased over the 2-year follow-up. Longer follow-up may be necessary to further characterize the refractive stability of CK.
Collapse
Affiliation(s)
- Danny Y Lin
- Department of Ophthalmology, Stanford University Medical Center, Stanford, CA 94305, USA
| | | |
Collapse
|
11
|
Murphy PJ, O'Brart DPS, Stephenson CG, Oliver KM, Patel S, Marshall J. Effect of Hyperopic Photorefractive Keratectomy on Corneal Sensitivity: A Longitudinal Study. J Refract Surg 2003; 19:34-9. [PMID: 12553603 DOI: 10.3928/1081-597x-20030101-07] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate corneal sensitivity after photorefractive keratectomy (PRK) for low hyperopia, as measured with a non-invasive stimulus. METHODS Two experimental groups were recruited: a control group of 17 patients (mean age 61.65 years) who underwent no treatment, and a PRK group of 11 patients (mean age 58.64 years) who underwent one of three attempted hyperopic corrections: +2.00 D (two patients), +3.00 D (four patients), +4.00 D (five patients). Corneal sensitivity was assessed centrally and peripherally, at temporal, medial, and inferior locations, approximately 1 mm from the limbus, using the Non-Contact Corneal Aesthesiometer (NCCA). Measurements were taken at each location for the control group and at preoperative, and postoperative weeks 1 and 2, 1, 3, and 6 months for the PRK group. RESULTS Comparison of control and PRK groups (preoperative sensation threshold) (t-test): central P=.715, temporal P=.719, medial P=.943, inferior P= .920. Comparison of longitudinal changes in PRK group (one-way ANOVA): central P=.612, temporal P=.997, medial P=.981, inferior P=.993. CONCLUSIONS Using the Non-Contact Corneal Aesthesiometer, no significant difference was found between the control and PRK groups for preoperative sensation thresholds, and no significant change in corneal sensitivity was found between any of the test time periods at any of the four corneal test locations for the PRK group.
Collapse
Affiliation(s)
- Paul J Murphy
- Department of Optometry and Vision Sciences, Cardiff University, Cardiff, United Kingdom.
| | | | | | | | | | | |
Collapse
|
12
|
El-Agha MSH, Johnston EW, Bowman RW, Cavanagh HD, McCulley JP. Photorefractive keratectomy versus laser in situ keratomileusis for the treatment of spherical hyperopia. Eye Contact Lens 2003; 29:31-7. [PMID: 12769154 DOI: 10.1097/00140068-200301000-00009] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To compare photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) in treating spherical hyperopia using the VISX STAR S2 excimer laser. INTERVENTION Fifteen consecutive eyes of 15 patients underwent PRK, and 16 consecutive eyes of 16 patients underwent LASIK (follow-up: 12 months). MAIN OUTCOME MEASURES Postoperative pain, uncorrected visual acuity (UCVA), deviation from intended correction, and loss of best spectacle-corrected visual acuity (BSCVA). RESULTS Mean preoperative spherical equivalent was + 2.18 diopter [D] for PRK and + 2.03D for LASIK. All PRK patients experienced significant postoperative pain that required systemic medication, whereas LASIK patients had minor and transient discomfort. Mean deviation from intended correction was -0.83D, + 0.01D, and + 0.18D at 1, 6, and 12 months after PRK, and + 0.22D, +0.30D, and + 0.40D at 1, 6, and 12 months after LASIK (P = 0.002 at 1 month). A higher proportion of LASIK eyes had a UCVA of 20/20 or better at all time points (P = 0.013 and 0.025 at 1 and 3 months, respectively). There was no statistically significant difference between both groups in BSCVA loss. CONCLUSIONS LASIK and PRK are comparable in efficacy and safety. However, PRK was more painful, with an initial and temporary myopic over-correction that did not occur after LASIK. Stability was achieved between 3 and 6 months following PRK, and one month following LASIK.
Collapse
Affiliation(s)
- Mohamed-Sameh H El-Agha
- Department of Ophthalmology, The University of Texas Southwestern Medical Center at Dallas, USA
| | | | | | | | | |
Collapse
|
13
|
McDonald MB, Hersh PS, Manche EE, Maloney RK, Davidorf J, Sabry M. Conductive keratoplasty for the correction of low to moderate hyperopia: U.S. clinical trial 1-year results on 355 eyes. Ophthalmology 2002; 109:1978-89; discussion 1989-90. [PMID: 12414402 DOI: 10.1016/s0161-6420(02)01255-1] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE To document the 1-year safety, efficacy, and stability results of 355 eyes treated in the multicenter study of conductive keratoplasty (CK) used to correct low to moderate hyperopia. DESIGN Nonrandomized comparative (self-controlled) trial. PARTICIPANTS Twenty surgeons at 13 centers performed CK on the eyes of all patients enrolled in a multicenter, 2-year, U.S. phase III clinical trial. Treated eyes had +0.75 to +3.00 diopters (D) of hyperopia and < or =0.75 D of cylinder. Patients were 40 years of age or older. INTERVENTION Low-energy, high-frequency current was applied directly into the peripheral corneal stroma through a delivery tip inserted at 8 to 32 treatment spots. The number of treatment spots was increased for increasing levels of hyperopia, but the amount of radiofrequency energy remained constant. Emmetropia was intended. All eyes were treated once (there were no retreatments). MAIN OUTCOME MEASURES Data from 355 eyes with 1 year of follow-up were analyzed for safety and stability, and data from 318 eyes were analyzed for efficacy and predictability, as well as stability and safety. All patients reported on satisfaction and quality of vision after surgery. RESULTS At 1 year, uncorrected visual acuity was < or =20/20 in 56%, < or =20/25 in 75%, and < or =20/40 in 92% of eyes. The manifest refractive spherical equivalent refraction was within 0.50 D in 63%, within +/-1.00 D in 89%, and within +/-2.00 D in 99%. Seven of 355 eyes lost 2 lines of best spectacle-corrected visual acuity at 1 year, but no eye lost >2 lines. One eye of 355 had induced cylinder of >2.00 D. The cycloplegic refractive spherical equivalent changed a mean of 0.25 +/- 0.50 D between months 3 and 6, 0.11 +/- 0.41 D between months 6 and 9, and 0.11 +/- 0.35 D between months 9 and 12. Refractive stability seemed to be attained by 6 months and remained stable through 12 months. Histology and confocal microscopy showed deep penetration of the treatment into the stroma. Endothelial cell counts were not changed by the treatment. CONCLUSIONS CK seems to be safe, effective, and stable for correcting low to moderate spherical hyperopia in patients 40 years old or older. Treatment penetration is deep and cylindrical in shape, and it does not damage the corneal endothelium. Uncorrected visual acuity, predictability, and stability are as good as or better than those obtained with other techniques used to correct hyperopia.
Collapse
|
14
|
Lian J, Ye W, Zhou D, Wang K. Laser in situ Keratomileusis for Correction of Hyperopia and Hyperopic Astigmatism With the Technolas 117C. J Refract Surg 2002; 18:435-8. [PMID: 12160152 DOI: 10.3928/1081-597x-20020701-03] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the effectiveness, predictability, and safety of laser in situ keratomileusis (LASIK) for correction of hyperopia and hyperopic astigmatism. METHODS Fifty-four hyperopic eyes of 35 patients with a spherical equivalent refraction between +1.00 and +6.00 D were followed for at least 12 months following LASIK. All surgery was performed with the scanning Chiron Technolas Keracor 117C excimer laser. Data on uncorrected and spectacle-corrected visual acuity, predictability, stability of refraction, and complications were analyzed. RESULTS At 12 months, the average residual refraction was +0.29 +/- 0.78 D; 83.3% of eyes (45 eyes) were in the range of +/- 1.00 D and 61.1% of eyes (33 eyes) were within +/- 0.50 D of emmetropia. Fifty eyes (92.6%) had uncorrected visual acuity of 20/40 or better and 34 (63.0%) eyes had 20/20 or better. One eye (1.9%) lost two lines of best spectacle-corrected visual acuity and two eyes (3.7%) gained two or more lines. Two patients (two eyes, 3.7%) had complaints of halos and one patient (one eye, 1.9%) had glare at 12 months after LASIK for hyperopia. CONCLUSIONS LASIK was used to treat hyperopia from +1.00 to +6.00 D with good predictability and safety. Primary and second hyperopia require different nomograms, according to our experience.
Collapse
Affiliation(s)
- Jingcai Lian
- Dept of Ophthalmology, Rui Jin Hospital, Shanghai Second Medical University, China.
| | | | | | | |
Collapse
|
15
|
McDonald MB, Davidorf J, Maloney RK, Manche EE, Hersh P. Conductive keratoplasty for the correction of low to moderate hyperopia: 1-year results on the first 54 eyes. Ophthalmology 2002; 109:637-49; discussion 649-50. [PMID: 11927418 DOI: 10.1016/s0161-6420(01)01022-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
OBJECTIVE To document the 1-year postoperative clinical results of the safety, efficacy, and stability of conductive keratoplasty (CK) to correct low to moderate hyperopia. DESIGN Prospective, nonrandomized, self-controlled trial. PARTICIPANTS Five surgeons at four centers performed CK on the first 54 eyes of a multicenter, 2-year clinical trial. Treated eyes had +0.875 to +4.00 diopters (D) of hyperopia and < or =0.75 D of cylinder. The nature of this procedure was explained to all participating patients who signed informed consent forms prior to undergoing the procedure. INTERVENTION Low energy, high-frequency current was applied directly into the peripheral corneal stroma through a delivery tip inserted at 16 or more treatment spots. An early nomogram was used for the first 54 eyes with an intended refraction of plano. MAIN OUTCOME MEASURES Data from all 54 eyes were analyzed for safety and stability. A subset of 30 of the 54 eyes was found that had been treated with the appropriate number of spots with the early nomogram. These eyes were categorized as current nomogram eyes; the data for these eyes were analyzed for efficacy and predictability, as well as stability and safety. All patients reported on satisfaction and quality of vision after surgery. RESULTS Preoperatively, the manifest refractive spherical equivalent refraction (MRSE) of the 30 current nomogram eyes was +1.57 D. At 1 year postoperatively, uncorrected visual acuity was 20/20 or better in 57% of the eyes and 20/40 or better in 93%. The MRSE was within 0.50 D in 46%, within +/-1.00 D in 93%, and within +/-2.00 D in 100%. No eye lost > or =2 lines of best spectacle-corrected visual acuity at 1 year postoperatively nor had an induced cylinder of > or =2.00 D. The MRSE changed a mean of 0.25 D +/- 0.43 between 3 and 6 postoperative months, 0.16 D +/- 0.38 between 6 and 9 postoperative months, and 0.07 D +/- 0.38 between 9 and 12 postoperative months. Refractive stability appeared to be attained by 6 months postoperatively. CONCLUSIONS Conductive keratoplasty appears to be safe, effective, and stable for correcting low to moderate spherical hyperopia. Stability appeared by the 6-month follow-up visit. For the eyes treated with the current CK nomogram, uncorrected visual acuity, predictability, and stability are as good as or better than those obtained with hyperopic laser in situ keratomileusis or noncontact laser thermal keratoplasty.
Collapse
|
16
|
Abstract
Although the first attempts at hyperopia correction were made more than 100 years ago, it is only in the past several years that the success of hyperopic refractive surgery has begun to approach the efficacy of myopia surgery. Corneal surgery for the correction of hyperopia includes older lamellar techniques such as automated lamellar keratoplasty and epikeratophakia, and more recently photorefractive keratectomy and laser in situ keratomileusis. The latter two procedures have shown the most success. Using large diameter laser ablations and improved keratomes, laser in situ keratomileusis has become a realistic alternative for corrections of up to 4 or 5 diopters with astigmatic corrections. Laser thermal keratoplasty using the Holmium or diode laser and contact techniques also have gained popularity and shown some potential. Collagen shrinkage procedures are easy to perform and have relatively few complications, but over correction and regression are problems. Crystalline lens surgery and phakic intraocular lenses are being investigated actively and are promising; however, safety issues persist. The surgical treatments of hyperopia present a significant challenge and reward for the ophthalmic surgeon.
Collapse
Affiliation(s)
- N A Sher
- University of Minnesota Medical School, Phillips Eye Institute, Minneapolis, Minnesota, USA.
| |
Collapse
|
17
|
Oliver KM, O'Brart DP, Stephenson CG, Hemenger RP, Applegate RA, Tomlinson A, Marshall J. Anterior Corneal Optical Aberrations Induced by Photorefractive Keratectomy for Hyperopia. J Refract Surg 2001; 17:406-13. [PMID: 11471997 DOI: 10.3928/1081-597x-20010701-01] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE Photorefractive keratectomy (PRK) for hyperopia requires both a steepening of the central cornea and a flattening of the mid-periphery to achieve its effect and is likely to affect the optical aberrations of the eye. METHODS Nine patients underwent PRK to correct between +2.00 and +4.00 D of hyperopia (first eye treated for each patient) using the Summit Technology Apex Plus excimer laser. Anterior corneal aberrations for pupil diameters of 3, 5.5 and 7 mm were estimated from corneal topography data (TMS-1), assuming a uni-index, single surface cornea. Refractive error was assessed using retinoscopy and standard subjective tests. RESULTS Apart from the intended change in refraction (mean spherical equivalent manifest refraction, +4.60 +/- 1.60 D before surgery and +0.70 +/- 1.60 D at 1 year after surgery), the most significant change was in spherical aberration. Anterior corneal spherical aberration was positive (+1.60 +/- 0.60 D for a 5.5-mm pupil) before surgery and became negative after surgery (-1.80 +/- 1.20 D at 1 year). The change in spherical aberration was related to the achieved change in refractive error. CONCLUSIONS The large change (approximately 3.00 D) in spherical aberration (from positive to negative aberration) has implications for the optical performance of the whole eye, where the effects of lenticular aberration must also be considered.
Collapse
Affiliation(s)
- K M Oliver
- Department of Vision Sciences, Glasgow Caledonian University, UK.
| | | | | | | | | | | | | |
Collapse
|
18
|
Yi DH, Petroll M, Bowman RW, McCulley JP, Cavanagh HD. Surgically induced astigmatism after hyperopic and myopic photorefractive keratectomy. J Cataract Refract Surg 2001; 27:396-403. [PMID: 11255051 DOI: 10.1016/s0886-3350(00)00788-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
PURPOSE To compare the axis and magnitude of surgically induced refractive astigmatism (SIA) after hyperopic and myopic photorefractive keratectomy (PRK). SETTING Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, Texas, USA. METHODS In this single-center retrospective study, the VISX Star S2 excimer laser was used to create a peripheral annular ablation profile to correct spherical hyperopia in 23 eyes of 16 consecutive patients. Attempted corrections ranged from +0.50 diopter (D) to +4.25 D with 0 to 1.00 D of astigmatism. The same laser was used to create a central ablation profile to correct spherical myopia in 25 eyes of 17 consecutive patients. Attempted corrections ranged from -2.25 to -6.50 D with 0 to 1.00 D of astigmatism. The absolute change in refractive astigmatism was calculated by taking the difference in magnitudes of astigmatism before and after laser treatment without regard to axis. Axis and magnitude of SIA were analyzed by vector differences. Magnitudes were compared using the Student t test, and axial shifts were compared using the chi-square test. All patients were followed for a minimum of 6 months. RESULTS The mean changes in absolute astigmatism were 0.29 +/- 0.28 D at 3 months and 0.34 +/- 0.29 D at 6 months after hyperopic PRK and 0.40 +/- 0.35 D at 3 months and 0.39 +/- 0.36 D at 6 months after myopic PRK. The mean vectoral magnitudes were 0.49 +/- 0.29 at 3 months and 0.52 +/- 0.25 at 6 months after hyperopic PRK and 0.48 +/- 0.39 at 3 months and 0.44 +/- 0.38 at 6 months after myopic PRK. The mean values for SIA (the centroid) were 0.10 +/- 0.57 D x 113 degrees at 3 months and 0.15 +/- 0.57 D x 131 degrees at 6 months after hyperopic PRK and 0.04 +/- 0.63 D x 160 degrees at 3 months and 0.08 +/- 0.58 D x 171 degrees at 6 months after myopic PRK. There was no statistically significant difference between the 2 groups in vectoral axis or magnitude of SIA. CONCLUSION Surgically induced astigmatism after hyperopic PRK was comparable to astigmatism induced by myopic PRK. A peripheral annular ablation for hyperopic correction, similar to a central ablation in myopic PRK, did not appear to result in uneven corneal healing causing astigmatism.
Collapse
Affiliation(s)
- D H Yi
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, Texas 75235-9057, USA
| | | | | | | | | |
Collapse
|
19
|
Affiliation(s)
- J D Primack
- Massachusetts Eye and Ear Infirmary, Boston 02114, USA
| | | |
Collapse
|
20
|
Lindstrom RL, Linebarger EJ, Hardten DR, Houtman DM, Samuelson TW. Early results of hyperopic and astigmatic laser in situ keratomileusis in eyes with secondary hyperopia. Ophthalmology 2000; 107:1858-63; discussion 1863. [PMID: 11013186 DOI: 10.1016/s0161-6420(00)00271-2] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Abstract
PURPOSE To assess the safety and efficacy of laser in situ keratomileusis (LASIK) for secondary hyperopia and hyperopic astigmatism and to develop a VISX STAR S2 LASIK nomogram (VISX Inc., Santa Clara, CA) for consecutive hyperopia after prior myopic refractive surgery. DESIGN Prospective, nonrandomized, self-controlled interventional study. PARTICIPANTS Thirty patients with consecutive hyperopia or hyperopia and astigmatism after LASIK, photorefractive keratectomy, automated lamellar keratoplasty, or radial keratotomy. INTERVENTION/METHODS Prospective evaluation of LASIK in 30 secondary eyes with fogged manifest sphere from +0.5 to +6.0 diopters (D) and cylinder from 0 to +5.0 D. MAIN OUTCOME MEASURES Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), and spherical equivalent (SE). RESULTS Mean manifest SE was +1.73 +/- 0.79 D before surgery, -0.13 +/- 1.00 D at 6 months after surgery, and -0.18 +/- 1.08 D at 1 year after surgery. At 6 months, 84% of patients with secondary hyperopia had UCVA of 20/40 or better; 76% were within +/-1 D of emmetropia. At 1 year, 85% had UCVA of 20/40 or better and 85% were within +/-1 D of emmetropia. No patients with secondary hyperopia lost 2 or more lines of BCVA at 1 year. Complications included intraoperative bleeding (3.3%), intraoperative epithelial defect (3.3%), transient interface debris (3.3%), significant dry eye (3.3%), blood in interface (3.3%), irregular astigmatism (6.7%), slight decentration (6.7%), trace haze (6.7%), or mild epithelial ingrowth not requiring removal (3.3%). CONCLUSIONS These early data suggest that LASIK for consecutive hyperopia from +0.5 to +5.50 D and astigmatism from 0 to +2.75 D using the VISX STAR S2 benefits from a nomogram adjusted for preoperative refraction, age, and prior refractive surgery, and is safe and effective.
Collapse
Affiliation(s)
- R L Lindstrom
- Minnesota Eye Laser and Surgery Center, Minneapolis, Minnesota, USA
| | | | | | | | | |
Collapse
|
21
|
Abstract
PURPOSE To review the major advances in the field of refractive surgery occurring over the past 25 years. METHODS Literature review. RESULTS The major developments in refractive surgery over the past 25 years are reviewed. CONCLUSIONS The past 25 years have witnessed great changes in refractive surgery. As a result of advancements in technology, instrumentation, and technique, we have seen improvements in the treatment of all types of ametropias. In this article, we review some of the successes and failures of the past quarter-century.
Collapse
Affiliation(s)
- R D Stulting
- Cornea Service, Emory University School of Medicine, Department of Ophthalmology, Atlanta, Georgia, USA
| | | | | |
Collapse
|
22
|
O'Brart DP, Stephenson CG, Baldwin H, Ilari L, Marshall J. Hyperopic photorefractive keratectomy with the erodible mask and axicon system: two year follow-up. J Cataract Refract Surg 2000; 26:524-35. [PMID: 10771225 DOI: 10.1016/s0886-3350(00)00329-1] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate efficacy and long-term stability of hyperopic photorefractive keratectomy (H-PRK) using the erodible mask and Axicon system. SETTING Department of Ophthalmology, St. Thomas' Hospital, London, England. METHODS Forty-three patients (43 eyes), with a mean preoperative refraction (spherical equivalent) of +4.54 diopters (D) (range +1.75 to +7.50 D), were treated using an Apex Plus(R) excimer laser (Summit Technology). This uses an erodible mask to ablate a 6. 50 mm diameter hyperopic correction and an Axicon to fashion a 1.50 mm blend zone around the correction. The overall ablation diameter was 9.50 mm. Follow-up was 2 years. RESULTS At 2 years, the mean manifest refraction was +0.16 D (range +4.125 to -4.000 D), with the induced correction appearing stable after 9 months. Based on the Munnerlyn algorithm, predictability was acceptable for corrections up to +4.50 D, with 68% of eyes within +/-1.00 D of the predicted correction. It was poorer for +6.00 D corrections, with 33% of eyes within +/-1.00 D of that expected. Patient satisfaction was high. Forty eyes (93%) had an improvement in uncorrected near visual acuity and 37 (86%), an improvement in uncorrected distance acuity. A peripheral ring of haze, 6.5 mm in diameter, appeared in all eyes 1 month postoperatively. Its intensity was maximal at 3 to 9 months and then diminished over time. There were no significant differences in measurements of the central corneal transparency at 12 and 24 months and those preoperatively. Measurements of flicker contrast sensitivity, forward light scatter (glare), and scotopic halos showed no significant differences between preoperative values and those measured after 6 months. CONCLUSIONS Achieved H-PRK corrections with the erodible mask and Axicon system agreed closely with the Munnerlyn algorithm, with refractive stability after 9 months. Predictability was acceptable for corrections up to +4.50 D. Axial corneal transparency was not compromised and visual performance, in terms of best spectacle-corrected visual acuity, forward light scatter, and night halos, was not impaired.
Collapse
Affiliation(s)
- D P O'Brart
- Department of Ophthalmology, United Medical and Dental Schools, St. Thomas' Hospital, London, England, UK
| | | | | | | | | |
Collapse
|
23
|
Abstract
The development of excimer laser technology, coupled with advances in lamellar corneal surgery, has heralded a new era in the treatment of refractive errors. This paper discusses the current status of hyperopic laser-assisted in situ keratomileusis. This surgical modality is at a relatively early stage of investigation but appears to offer promise for the surgical correction of hyperopia. This paper considers the evolution of the technique, analyzes the current literature, and discusses the current indications, limitations, and possible future developments.
Collapse
Affiliation(s)
- D P O'Brart
- Department of Ophthalmology, St. Thomas' Hospital, London, UK
| |
Collapse
|
24
|
|